YKE2608MH

Features
32-bit DSP control, low noise and superior vibration performance
16 constant torque microstep setting, up to 256 microsteps
Smooth and accurate current control, High-speed output increased by 7%,
effectively reduce motor heating
The highest pulse response frequency is 200KHZ
When the pulse stops over 200ms, the motor current is halved
Differential signal input, compatible with 5V/24V signals.
Stepper
Drive New single-double pulse function, single/double pulse function switching
2 Phase
through shorting or disconnecting the internal terminals of the drive
Optically isolated differential signal input, strong anti-interference ability
Drive current is adjustable below 6.0A
Voltage input range: AC18~80V
With over voltage, under voltage etc. fault protection

Small size, volume 151*94*54 (mm³), weight 0.5kg

Suitable for 57-86mm(NEMA23-34) 2 phase open-loop stepper motors.

Stepper
Drive Application: Mainly used in engraving machines, laser equipment, labeling machines, electronic equipment,
3 Phase advertising equipment, packaging equipment

Dimensions

Dimensions (mm) Drive Wiring Diagram


Side Front

Close-
Loop Direction signal -
Stepper Direction signal +
Drive
Pulse signal -
Pulse signal +
Motor free signal -
Motor free signal +
Power indicator(green)
Home signal indicator
Overcurrent indicator
Single/double pulse setting
Microstep setting

Lock current selection


Current setting

Close-
Input Signal Timing Diagram A Phase
Loop Motor
Stepper B Phase
Motor PU: Pulse signal
2 Phase
2.
DR: Direction signal

MF: Motor free signal

7
YKE2608MH Microstep Setting
Microstep
PU/Rev

S9: Single and double pulse OFF=PU&DR, ON=CW&CCW

YKE2608MH Current Setting Stepper


Drive
Current RMS 2 Phase

Current Peak

Sw4: OFF= Half Current


ON= Full Current
Terminal Introduction
Symbol Function Specification
Stepper
Drive
Power indicator When power on, the green indicator lights up. 3 Phase
Pulse signal indicator, when there is continuous pulse input, the green
Work indicator
indicator light flashes, otherwise the green indicator light is always on.

Fault indicator When over current or under voltage, the red indicator lights up.
Used to change motor direction. Requirements: low level 0~0.5V, high level
SW9=OFF, it’s direction control signal 5~24V
Effects on falling edge, the motor moves a step when the pulse goes from high to
SW9=ON, it’s CCW pulse signal
low. It requires: low level 0~0.5V, high level 5~24V, pulse width>2.5us.
Connect with the signal power supply, 5V~24V can drive, need to connect a current
Input signal + limiting resistor with DR- when >24V

SW9=OFF, it’s pulse signal Close-


Effects on falling edge, the motor moves a step when the pulse goes from high to
low. It requires: low level 0~0.5V, high level 5~24V, pulse width>2.5us. Loop
SW9=ON, it’s CW pulse signal Stepper
Drive
Connect with the signal power supply, 5V~24V can drive, need to connect a current
Input signal + limiting resistor with PUL- when >24V
When effective (low level), motor coil current is turned off, motor free and alarm
Motor free/ Alarm clear signal signal cleared.

Input signal + Connect with the signal power supply, 5V~24V can drive, need to connect a current
limiting resistor with MF- when >24V

Power supply +
AC18~80/DC24~110V
Power supply -

N/A
Close-
Motor connection Loop
8 leads 8 leads
4 leads 6 leads (For low speed) (For high speed)
Stepper
N/A Motor
2 Phase
Notice 1. Input voltage should not exceed AC48V.
2. The input control signal level is DC5-24V. The current limiting resistor needs to be connected when>24V.
3. When overcurrent, overvoltage or undervoltage, the O.C light flashes, please restart the power
supply after eliminating motor connection and other short-circuit faults.
4. The green PWR indicator lights up when the drive is powered on.
5. When there is pulse input, TM indicator flashes; otherwise, TM indicator is always on.

You might also like