Example ICT Testing Protocol PDF
Example ICT Testing Protocol PDF
_____________________________________________________________________________________________________
ANNEX V:
C/ Toledo, 176 - MADRID 28005 - Phone. 913660063 - Fax: 913664655 - [Link] - plcmadrid@[Link]
ADVANCED AUTOMATION AND TRAINING
_____________________________________________________________________________________________________
1.2.-Representative lastName
legal Nombre NIF:
1.3.-Registration/File Number: M / 00 / 000000 / ICT
1.4.- Situation and description of the building or group of buildings: BUILDING LOCATED ON TOLEDO STREET, 178
MADRID - 28000. CONSTRUCTION OF 18 OFFICES AND GARAGES. FLOORS: 7 AND OFFICES: 18
1.5.-List of installed materials: (The list will include the brand and model of the installed materials)
MATERIAL BRAND MODEL
ANT. UHF DAT HD TELEVES 1495
ANT. FM CIRCULAR C/N TELEVISION 1201
ANT. DAB Y3E 8DB. C/N TELEVÉS 1050
COAX CABLE T100PE NGRO TELEVISED 2155
MASTIL 3000 45 X 2 MM. TELEVES 3010
PARABOLIC SUPPORT TELEVE 7390
1.5.- List of installed materials: (The list will include the brand and model of the installed materials)
MATERIAL BRAND MODEL
PVC M-40 PIPE HIMEL RAL7040
TUBE M-63 HIMEL RAL 7063
PVC CHANNEL 230x60 mm UNEX
PVC TUBE M-25 FP25
PVC PIPE M-20 FP20
MECHANISM BOX 23008
Brand Model/Type
____________________________________________________________________________________________________
C/ Toledo, 176 - MADRID 28005
ADVANCED AUTOMATION AND TRAINING
B) Mast/Tower
Type No. of elements Length (m)
Brand Model/Type
a) Installed elements
RF+FI mixer TELEVÉS Ref. 7407
E) Distribution (The location will be specified in cases where it differs from that contemplated in the Project).
F) Number of takeouts:
The number of installed outlets matches the specifications in the Technical Project.
The number of installed outlets does not match what is indicated in the Technical Project (Describe the modification)
B) Signal levels at user outlet in the best and worst case of FM and TV for each branch according to Technical Project.
a) Band 15 - 862 MHz. Signal levels in dBμIn the carriers of video and sound for each channel for
analog television and at the central frequency of each channel for digital television.
b) Band 950 – 2150 MHz. (Only when there are no reception systems for broadcasting and television signals)
Satellite). The attenuations between the headend and will be determined with the help of a FI simulator or other equivalent device.
the best and worst shot of each branch for three significant frequencies in the band.
Signal level of Test signal level at the best Test signal level at the worst
exit of case of each branch (dBμV/75Ω) case of each branch (dBμV/75Ω)
Frequency
FI simulator
(MHz) in the header Branch 1 Branch 1
(dBμV) Office 2 - 4th Floor Office 1 - 2nd Floor
1st F.I. 960 108.6 60.0 52.0
2nd F.I. 1550 108.4 60.3 52.9
3rd F.I. 2140 108.8 60.1 52.2
Frequency of
BER (ext 1)
canal
570.00 <1.0E-8
618.00 <1.0E-8
698.00 <1.0E-8
706.00 <1.0E-8
746.00 <1.0E-8
770.00 <1.0E-8
778.00 <1.0E-8
810.00 <1.0E-8
834.00 <1.0E-8
842.00 <1.0E-8
850.00 <1.0E-8
858.00 <1.0E-8
Continuity: ≤ 3.0Ω
Resistance: 4.8Ω≤ 10Ω
Cross-section of the grounding cable: 25 mm2
general land of the building.
Connection: exclusive land.
other circumstances.
4.2.- When parabolic antennas are incorporated into the ICT for receiving satellite signals, it must be
does not proceed
Parable directed to: Brand Model Characteristics
C/ Toledo, 176 - MADRID 28005 - Phone. 913660063 - Fax: 913664655 - [Link] - plcmadrid@[Link]
ADVANCED AUTOMATION AND TRAINING
4.3.- Level of the signals received at the input and output of the head amplifier at three frequencies
significant to the band and in user taking and in the best and worst cases of each branch: NOT APPLICABLE
Level of Level of Test signal level at best Test signal level at worst
signal of signal of case of each branch (dBμV/75Ω) case of each branch (dBμV/75Ω)
entry in exit in
Frequency header header Branch Branch
according to according to
project project 1 1
dBμV) (dBμV)
1st F.I.
2nd F.I.
3rd F.I.
The error rate will be measured, at least, in the digital satellite television channels in the worst case of each branch.
Frequency of BER (extension 1) BER (extension 2) BER (extension 3) BER (extension 4) BER (extension ...N)
canal
b) Community rulers.
Content:
Interconnection strips
Quantity 10
Type of power strip Cut and test 10 pairs
Brand: Televes
Model: TB STRIP 10 PAIRS / Ref, 2172
B) Distribution network
a) Cables:
Number 1/1
Type of cover 1 cable 50 P
Caliber / Number of pairs PVC
Specific characteristics 0.51 / 50 P
-----
Portal 1
100
Quantity 3 3 4
Quantity 3 3 4
Quantity 3 3 3
Phone PAU 2 Phone PAU 2 Phone PAU 2
Type
lines lines lines
b) Insulation resistance: The insulation resistance of all connected pairs, measured from the Register
Main with 500V of direct current voltage between the two conductors of the network, or between either of these and ground, shall not
be less than 100MΩ (at least one BAT per dwelling will be verified) is:
1) Minimum measured value: 128.0 MΩ ≥ 100 MΩ
F) Number of shots:
All the indicated connections in the Technical Project for each home exist, their location corresponds to the
indicated in the same, they are properly connected and the continuity from the Take Register is correct.
____________________________________________________________________________________________________
C/ Toledo, 176 - MADRID 28005
ADVANCED AUTOMATION AND TRAINING
_____________________________________________________________________________________________________
C/ Toledo, 176 - MADRID 28005 - Tel. 913660063 - Fax: 913664655 - [Link] - plcmadrid@[Link]
ADVANCED AUTOMATION AND TRAINING
Operator Registration.
Access from the top RITS
Limited and marked space for each operator
Ventilation Yes
Electrical conduits to the protection panel Yes
There is an electrical protection panel equipped
of 2 units of 3 thermal magnetic circuit breakers 16A /
Equipped protection panel 16A / 10A
2 differential switches 25 A and 1 IAG 25 A
GENERAL CHARACTERISTICS
Dimensions 2000x1000x500 mm
Construction work done with door
Constructive characteristics metallic equipped with a lock with
key.
Location of the venue Portal - Covered Floor
Ladders or conduits for cable laying DOES NOT PROCEED
Ventilation Yes
Electrical wiring up to the protection panel Yes
There is a Protection panel
electric equipped with 2 units of 3
Protection panel circuit breakers 16A / 16A / 10A
2 differentials 25 A and 1 IAG 25 A
Plugs It has been equipped with 2 16A sockets.
RTV: 18
TB: 18
Taking Records 64x64x42 mm 64x64x42 mm
0
RESERVA: 0
(*) Schemes of the interior user canalizations will be attached, in cases where they differ from the
contemplated in the Technical Project.
Date, signature, and seal of the installing company Date, signature and seal of the project manager (if applicable) (1) and visa of the
Professional College corresponding
In Madrid, April 28, 2011