Basics of Signal
Basic definitions
A signal is an abstraction of any measurable quantity that
is a function of one or more independent variables such as
time or space
Voltages and currents are common electrical signals
Signals can be continuous or discrete
A continuous time signal is one that is present for all
instants in time and space example is voltage on a wire
A discrete time signal is only present at discrete times
Often discrete time signals are samples of a continuous
time signal
A system is an abstraction of anything that takes an input
signal, operates on it and produces an output signal
Signals and systems theory is the framework for most
engineering knowledge
Basic Periodic Signal Terminology
Periodic repeating
v(t T ) v(t )
Mathematical model from trigonometry
y A sin(t )
A Amplitude
f requency
phase
2
Period
Frequency is defined in radians/second where 2
radians = 1 cycle or 360 degrees
Example from Simple Sine Wave in
Time and Freq Domain.VI
Basic Periodic Signal Terminology
Period or WaveLength(one cycle)
Amplitude
Frequency =
1/Period (cycles/second)
or
2
period
rads/sec
Periodic Signal Terminology
Frequency (f)= 1/(time to perform one cycle)
This yields a value in hertz or cycles/per second
Often we talk in radians per second
There are 2 radians in a 360 degree cycle
So 2 x f = frequency (rads/sec) =
Phase Terminology
Phase difference
sin(x) = cos(x - 90 degrees) = cos( x )
2
sin(x) lags cos(x)
cos(x) leads sin (x)
Fourier Series
Fourier Series
Fourier square wave.vi
N=0
N=3
N=1
N=4
N=2
N=20
Fourier triangle.vi
N=0
N=2
N=1
N=4
Fourier rectangular sawtooth wave.vi
N=0
N=1
N=20
N=2
N=3
Why is understanding Fourier Series
important in Instrumentation and
Measurement ?
Every time a signal changes state, the entire Fourier
content is present, whether it is desired or not
If you are monitoring a voltage channel on an instrument
and it is powered off, and you power the instrument on and
the voltage being measured makes a step change, the entire
Fourier series content associated with a square wave is sent
down the wiring connecting the instrument to the data
acquisition system
All wires have a certain amount of resistance and
capacitance which acts as a filter to some of the frequency
content, particularly the higher frequencies
This results in distortion of the signal from the actual shape
Time and Frequency Domains
Previous examples have shown signals varying as a function
of time. These are said to be representations in the time
domain.
Signals can also be represented in the frequency domain
In the frequency domain they are expressed as functions of
frequency
A typical way to look at a signal in the frequency domain is
with a power spectral density (PSD) plot
A PSD shows the distribution of power in the various
frequencies of a signal
As we can see from Fourier Series, a signal may in fact be
composed of many different signals
When we look at a composite signal as components of different
frequencies, we are working in the frequency domain
Power Spectral Density Example
Plot of sin(x) + sin(2x) + 2 sin(6x) + 3cos(9x)
Example from Multiple Sine Waves in Time and Freq Domain.VI
Noise
Noise is undesired signal or contamination of a signal we want to
measure
Average White Gaussian Noise (AWGN) equal power at all frequencies
AWGN
Frequency Specific Noise
Amplitude
Power at a specific frequency
freq
Alternating current (AC) power in house wiring in India is a periodic
waveform at 50 hertz
It is not uncommon to find 50 hertz noise in electrical systems due to
electromagnetic interference from wiring systems
The amount of signal present versus the noise present is expressed in the
Signal to Noise Ratio (SNR)
It is usually expressed in decibels
SNR 20 log
Signalvoltage
Noisevoltage
10 log
Signalpower
Noisepower
Much of the work of instrumentation engineers involves extracting
signals and rejecting the noise
SNR is thus an important figure of merit to instrumentation engineering
Example using Signals and Noise.VI
Sources of Noise
NOISE
SOURCE
CONDUCTIVE
CAPACITIVE
INDUCTIVE
RADIATIVE
COUPLING CHANNEL
AC POWER LINES
COMPUTERS
DIGITAL LINES
RECEIVER
(SIGNAL
CIRCUIT)
TRANSDUCER
SIGNAL CABLES
MEASUREMENT CIRCUIT
From Improved Signal Quality Via Conditioning by Lauren Sjoboen at
www.ni.com
Filters
Instrumentation engineers use filters to reject
unwanted signals (noise) and leave only the desired
signals
Filters are classified by the frequencies they accept
or reject
Filters are a key part of signal conditioning in any
instrumentation and data acquisition system
Here we just want to understand the idea that we
can filter signals to remove signal content of
undesired frequencies
Types of Filters
Type
Ideal Transfer as a
function of
frequency (|H(f)|)
Lowpass
1
1
0
Bandpass
Band Reject
or Notch
f1
f2
1
0
Removes all signals
with frequency > fc
Noise removal, data
interpolation, smoothing
Removes all signals
with frequency < fc
Removing DC or low
frequency drift, edge
detection or
enhancement
Removes all signals
outside of the range
of f1 to f2
Tuning in a frequency on
a radio receiver,
separating a subcarrier
Removing all signal
at a particular
frequency range f1
to f2
Removing a particular
noise like power line
hum at 60 hz
fc
1
0
Example Use
fc
Highpass
Description
f1
f2
Noise
contaminated
signal
Example from Extract the Sine Wave.VI
Signal
after
LowPass
Filter
Real filter from Signals and Systems Made Ridiculously Simple
Steady State and Transient
Response
Most systems have two types of response to an input
The dynamic or transient response short lived
response driven by an imbalance of forces
The steady state response a balanced unchanging state
This is not only for electrical systems but also for structural
systems (mass spring damper), thermal systems and
chemical systems
The study of dynamic response is a critical part of
engineering that is based on the use of differential
equations and the Laplace transform.
Why is steady state and transient
response important for understanding
instrumentation ?
We have to be able to characterize and separate the
response of sensors to a changing input from the response
of the system to changing conditions
If a sensor is bouncing around in response to an input, it
will not provide a good measurement
Measurement errors result when the transient or steady
state response of a sensor is not perfect (non-ideal)
Most measurement time histories are a combination of
transient and steady state response
We need to be able to use the terminology properly to
describe what we are measuring
Types of ideal inputs
Unit Ramp
Amplitude
Unit Step
Amplitude
Unit Impulse (Dirac
Delta Function)
Time Domain
Representation
Amplitude
Type of Input
Description
Example
Instantaneous
application and
removal of
input
A hammer strike
on a structure, a
high speed
electrical signal
Instantaneous
application of
signal which
remains
Power on of
equipment.
Application of
weight on a
structure
Continuously
increasing
input
Fluid level of a
tank
Time
1
Time
1
Time
For this lecture we are going to concentrate on unit step response
Types of System Response
Sensor dynamics generally fall into one of three categories:
First order low pass
Second Order low pass
Overdamped
Underdamped
Critically damped
Bandpass
Sensors that only respond to a certain range of
frequencies
Very common in acoustic sensors (microphones)
and in certain accelerometers
First Order Dynamics
If the quantity under measurement is x(t) and the sensor output is v(t)
then a sensor with first order dynamics can be represented by the
ordinary differential equation
v x (t ) avx (t ) Kx (t) wherea natural frequencyof the sensor
Multiply both sides by
1
where is the time constantof the system
a
vx (t ) vx (t ) Kx(t ) , this has a closed form solution
t
(1 eat ) X 0 K 1 exp
where X 0 is the value of x at time zero
vx (t )
X 0K
a
If this is the case, the response is 63 % of the steady state in
secs
Within 5% of the steady state value for t 2
And within 2% of the response within 2% of the steady state for t 3
This should be recognizable as the time response of a simple R-C circuit from the
last lecture where RC
Many thermal sensors are first order sensors
First order system response to a
step input
from Northrop Introduction to Instrumentation and
Measurements
Types of Second Order Dynamics
Second order sensor
dynamics fall into one of
three categories,
depending on the location
of the roots of the
characteristic equation of
the differential equation
that describes the sensor
These categories are
underdamped (complex v v (2 ) v 2 Kx(t )
x
x
n
x n
conjugate roots)
critically damped (two
2
v
v
(
2
a
)
v
a
Kx(t )
x
equal roots)
x
x
Overdamped (unequal
real roots)
v x v x (a b) vx ab Kx(t )
These three cases are
damping _ factor ( zeta )
represented by the
corresponding ordinary
n natural _ frequency (rad / sec)
differential equation
kA
Equations for Second Order Response
Solving the differential equations for the step response
leads to the following results
KX 0
1
nt
2
vx (t ) 2 1
e
sin n 1 t (underdamped)
2
n
1
1 2
where tan
KX 0
vx (t ) 2 1 e at ateat (critically damped)
a
KX 0
1
at
bt
vx (t )
1
(
be
ae
) (overdamped, b a)
ab b a
Underdamped
Critically damped
2nd Order Step
Response from
Northrop
Introduction to
Instrumentation
and
Measurements
This is a time
domain
representation of
the response to a
step input
Overdamped