Manual SmartClass Ethernet
Manual SmartClass Ethernet
SmartClass
Ethernet Tester Users Guide
Notice
Every effort was made to ensure that the information in this document was accurate at the time of printing. However, information is subject to change without notice, and JDSU reserves the right to provide an addendum to this document with information not available at the time that this document was created. Copyright 2009, JDS Uniphase Corporation. All rights reserved. JDSU, Enabling Broadband and Optical Innovation, Communications Test and Measurement Solutions, and the JDSU logo are trademarks of JDS Uniphase Corporation (JDS Uniphase). All other trademarks are the property of their respective owners. No part of this guide may be reproduced or transmitted electronically or otherwise without written permission of the publisher. JDS Uniphase, JDSU, and SmartClass are trademarks or registered trademarks of JDS Uniphase Corporation in the United States and/or other countries. Microsoft and Excel are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. PDF is a trademark of Adobe Systems in the United States and/or other countries. Energizer is either a trademark or registered trademark of Eveready Battery Company, Inc. in the United States and/or other countries. Specifications, terms, and conditions are subject to change without notice. All trademarks and registered trademarks are the property of their respective companies.
Copyright
Trademarks
Ordering information
This guide is a product of JDSU's Technical Information Development Department, issued as part of the SmartClass Ethernet Tester. The catalog number for a printed guide is ML-5053901. The catalog number for a CD containing all user documentation and utilities is CML-21099708. This product was tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial or residential environment. This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. The authority to operate this product is conditioned by the requirements that no modifications be made to the equipment unless the changes or modifications are expressly approved by JDSU.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada.
This product was tested and conforms to the EMC Directive, 89/336/EEC as amended by 92/31/EEC and 93/68/EEC for electromagnetic compatibility. SmartClass Ethernet Tester Users Guide
ii
This product was tested and conforms to the Low Voltage Directive, 73/23/EEC as amended by 93/68/EEC. Conformity with this directive is based upon compliance with the harmonized safety standard, UL61010-1. JDSU has established processes in compliance with the Waste Electrical and Electronic Equipment (WEEE) Directive, 2002/96/EC, and the Battery Directive, 2006/66/EC. This product, and the batteries used to power the product, should not be disposed of as unsorted municipal waste and should be collected separately and disposed of according to your national regulations. In the European Union, all equipment and batteries purchased from JDSU after 2005-08-13 can be returned for disposal at the end of its useful life. JDSU will ensure that all waste equipment and batteries returned are reused, recycled, or disposed of in an environmentally friendly manner, and in compliance with all applicable national and international waste legislation. It is the responsibility of the equipment owner to return equipment and batteries to JDSU for appropriate disposal. If the equipment or battery was imported by a reseller whose name or logo is marked on the equipment or battery, then the owner should return the equipment or battery directly to the reseller. Instructions for returning waste equipment and batteries to JDSU can be found in the Environmental section of JDSUs web site at www.jdsu.com. If you have questions concerning disposal of your equipment or batteries, contact JDSUs WEEE Program Management team at WEEE.EMEA@jdsu.com.
iii
iv
Table of Contents
ix Purpose and scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x Assumptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x Safety and compliance information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x Technical assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Chapter 1
Getting Started
Ship list. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features and capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Whats new . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Options and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preparation for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Changing the AC line plug fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exploring the front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Status LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cancel key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OK key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Arrow keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Action key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Start key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Backlight key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exploring the connector panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exploring the bottom panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Powering ON your tester. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Powering OFF your tester. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 2 2 3 3 3 4 5 5 5 6 6 6 6 7 7 7 7 7 7 7 8 8 9 9
Table of Contents
Navigating the user interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Battery icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Menu screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Data entry screens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Result screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Using the keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Selecting a menu option or a configuration setting . . . . . . . . . . . . . . . . 13 Returning to a previous menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Entering numeric values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Typing text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Locking the keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Chapter 2
Setting the language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing software versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting the date and time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Changing the date or time format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting the date or time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjusting the contrast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Loading software upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enabling options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Verifying enabled options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Determining the specified battery type . . . . . . . . . . . . . . . . . . . . . . . . . . Restoring factory defaults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Instrument Settings
15 16 16 16 16 17 17 17 18 18 18 18
Chapter 3
About Ethernet testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Running cable diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Measuring optical power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Launching an Ethernet test application . . . . . . . . . . . . . . . . . . . . . . . . . . Initializing the link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying L2 test application settings . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying Ethernet settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying payload settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying VLAN or Q-in-Q settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring the traffic load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmitting a constant load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmitting a bursty load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmitting a ramped load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmitting a flooded load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying Ethernet filter settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmitting layer 2 traffic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BER testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Measuring service disruption time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inserting errors or pause frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmitting layer 2 patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Loopback testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the L2 Loopback application . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the automatic loopback feature . . . . . . . . . . . . . . . . . . . . . . . . . . Starting or restarting a test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stopping traffic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Running a timed test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ethernet Testing
19 20 20 21 21 22 22 24 25 26 27 28 28 29 30 31 32 33 34 34 35 35 36 36 37 38 38 38
vi
Table of Contents
Chapter 4
About IP testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Launching an IP test application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Initializing the Ethernet link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying L3 test application settings . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying Ethernet settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying payload settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying VLAN, Q-in-Q, or MPLS settings . . . . . . . . . . . . . . . . . . . . . Configuring the traffic load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifying IP settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filtering received layer 3 traffic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmitting layer 3 IP traffic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inserting errors or pause frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Loopback testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Understanding MPLS loopbacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the L3 Loopback application . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the automatic loopback feature . . . . . . . . . . . . . . . . . . . . . . . . . . Ping testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Running TraceRoute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Starting or restarting a test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stopping traffic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IP Testing
41 42 42 43 43 43 44 45 46 46 47 48 49 49 50 50 51 52 54 55 55
Chapter 5
About multiple streams testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Launching a multiple streams test application. . . . . . . . . . . . . . . . . . . . Initializing the link for multiple streams . . . . . . . . . . . . . . . . . . . . . . . . . Specifying common stream settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enabling traffic streams and configuring the load. . . . . . . . . . . . . . . . . Configuring individual traffic streams. . . . . . . . . . . . . . . . . . . . . . . . . . . Copying a streams settings to all streams. . . . . . . . . . . . . . . . . . . . . . . Transmitting multiple streams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Loopback testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing test results for a stream . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
57 58 58 59 60 61 61 63 63 63 64
Chapter 6
About RFC 2544 testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard symmetrical RFC 2544 test . . . . . . . . . . . . . . . . . . . . . . . . . New asymmetrical RFC 2544 test . . . . . . . . . . . . . . . . . . . . . . . . . . . . Running an RFC 2544 test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing the RFC 2544 log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65 66 66 66 67 70
Chapter 7
About configuration and result files . . . . . . . . . . . . . . . . . . . . . . . . . . . . Saving configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing saved configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Restoring saved configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Saving results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing saved results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Deleting saved configurations or results . . . . . . . . . . . . . . . . . . . . . . . .
Managing Files
71 72 72 72 73 73 73 74
vii
Table of Contents
Chapter 8
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing test results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Freezing test results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Summary results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Link Status results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP Config Status results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP Config Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Link Stats results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Link Counts results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Stats results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stream results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2 BERT Stats results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2 Pattern Stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ping Stats results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TraceRoute Log results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable Diagnostics results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Link Status category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MDI or MDIX Pair Status result . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000M Pair Swap results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polarity result . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pair Skew result. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fault results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optical Signal results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
75 76 76 77 77 78 80 81 81 83 85 86 87 87 88 88 88 88 89 89 90 90 90 90
Chapter 9
Maintaining the Batteries 91 Prolonging battery life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Recharging the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Replacing the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Chapter 10
Getting Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Resolving problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethernet and IP testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting
95 96 96 96 96
Appendix A
Specifications
viii
This chapter describes how to use this guide. Topics discussed in this chapter include the following: Purpose and scope on page x Assumptions on page x Safety and compliance information on page x Technical assistance on page x Conventions on page xi
ix
Assumptions
This guide is intended for novice, intermediate, and experienced users who want to use the SmartClass Ethernet Tester effectively and efficiently. We are assuming that you have basic computer experience and are familiar with basic telecommunication concepts, terminology, and safety.
Technical assistance
If you need assistance or have questions related to the use of this product, use the information in Table 1 to contact JDSUs Technical Assistance Center (TAC) for customer support. Table 1
Region Americas
hotline.europe@jdsu.com
During off-hours, you can request assistance by doing one of the following: leave a voice message at the TAC for your region; email the North American TAC (tac@jdsu.com); submit your question using our online Technical Assistance request form at www.jdsu.com.
Conventions
This symbols and safety terms used in this guide are described in the following tables.
Table 2
Symbol conventions
This symbol represents a general hazard.
This symbol represents a risk of explosion This symbol represents a Note indicating related information or tip.
This symbol, located on the equipment, battery, or packaging indicates that the equipment or battery must not be disposed of in a land-fill site or as municipal waste, and should be disposed of according to your national regulations.
Table 3
DANGER
Safety definitions
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
xi
xii
Chapter 1
Getting Started
1
This chapter provides a general description of the SmartClass Ethernet Tester. Topics discussed in this chapter include the following: Ship list on page 2 Features and capabilities on page 2 Whats new on page 3 Options and accessories on page 3 Preparation for use on page 5 Exploring the front panel on page 6 Exploring the connector panel on page 8 Exploring the bottom panel on page 8 Powering ON your tester on page 9 Powering OFF your tester on page 9 Navigating the user interface on page 9 Using the keypad on page 13
Ship list
The Ethernet Tester typically ships in anti-static packing material to stabilize the tester inside the box. The following items ship standard with the SmartClass Ethernet Tester: SmartClass Ethernet Tester tester. Universal Power Adapter A power adapter designed specifically for the SmartClass Tester is included. When supplying power to the SmartClass Tester using an adapter, you must use the adapter supplied with your tester. Additional AC line plug adapters are also included. Carrying Bag 4 AA Rechargeable NiMH Batteries Shielded Ethernet Cable USB Cable Documentation CD. The Users Guide is included as a PDF on the CD. The Download Manager utility is also provided on this CD. Safety and compliance information is provided separately, in printed format. When unpacking the tester, verify that each of the standard items, and any optional items you ordered, are included in the package.
Whats new
This release of the SmartClass Ethernet tester includes the following new features: Lockable keypad. You can lock your keypad during testing to prevent unintentional key presses that might disrupt or end the test. Multiple traffic streams. The tester can now transmit and analyze up to eight independent streams of layer 2 or layer 3 traffic. When configuring the traffic, you can optionally assign a unique source MAC or IP addresses to each individual stream, or you can use the same source address for all streams. Configurable Acterna Test Packets (ATPs). You can now specify a fill byte pattern for Acterna Test Packets. The pattern is used to populate the payload. MPLS encapsulation.The tester now allows you to transmit layer 3 IP traffic over a MPLS network by specifying MPLS label settings when you configure traffic for single stream tests. IP Filter results. The source and destination addresses carried in filtered layer 3 IP traffic now appear as test results when running single stream layer 3 tests. Asymmetrical RFC-2544. An asymmetrical RFC-2544 script is now available which allows you to run the script in an end-to-end configuration at different upstream and downstream line rates. The script is initiated by a master tester on the near end. The master tester then automatically configures the slave tester on the far end. Layer 4 loopbacks. You can loopback received layer 4 traffic when running Layer 3 Traffic tests. Traffic is not analyzed for layer 4 statistics, the tester simply swaps the source and destination port numbers carried in the received traffic before looping it back to the source device.
Software options
When you order your tester, you can order the following software options to expand your testing capability: TRAFFIC (TRF). The TRAFFIC software option allows you to generate and transmit traffic over a 10/100/1000 Base-T/Tx electrical interface. If you purchase the OPTICAL software option too, your tester can also generate and transmit traffic over a 1000Base-X optical interface. OPTICAL (OPT). The OPTICAL software option allows you to use the SFP jack on your tester to loopback 1000Base-X optical Ethernet traffic. If you purchased the TRAFFIC software option too, your tester can also generate and transmit traffic over a 1000Base-X optical interface. MPLS (MPL). The MPLS software option allows you to tag and analyze MPLS encapsulated traffic. For details, see Specifying VLAN, Q-in-Q, or MPLS settings on page 45.
STREAMS (STR). The STREAMS software option allows you to transmit and analyze up to eight individual streams of traffic. For details, see Chapter 5 Multiple Streams Testing. ASYMETRICAL RFC (ASY). The ASYMETRICAL RFC software option allows you to run an RFC test in an end-to-end configuration with different uplink and downlink speeds. For details, see the New asymmetrical RFC 2544 test on page 66. You should also purchase a JDSU recommended SFP for optical testing. Each of the SFPs offered by JDSU as an option is MSA compliant. Please refer to your SFP manufacturers site for detailed specifications.
Accessories
Table 4
Catalog Number AC-SFP-1000SX AC-SFP-1000LX AC-SFP-1000ZX AC-SFP-1000BX1 AC-SFP-1000BX2 AC-SFP-CWDM CB-019011 CB-019013 CB-019052 CB-019054 CB-019055 CB-019056 CB-019057 CB-019058 CB-50747 CB-50759 3010-12-0101 SC1WALLCHARGER BATTAA25AHNIMH4PACK C11-015765
To order accessories for your Ethernet Tester, or for a list of currently supported SFPs, contact JDSU Customer Care, your JDSU TAC representative, or your local JDSU sales office. You can also contact JDSU through the company web site, www.jdsu.com.
General preparation
When you unpack the Ethernet Tester, do the following: Inspect the tester for damage. If undamaged, save the box and packing materials in case you need to ship the tester in the future. Before using the Ethernet Tester for the first time, do the following: If you are using alkaline batteries, verify that your tester is OFF, and then install fresh batteries in the tester. If you are using rechargeable batteries, verify that your tester is OFF, and then install the batteries in the tester. Before testing, make sure the batteries have been fully charged (see Recharging the batteries on page 92). Turn the tester ON (see Powering ON your tester on page 9). When prompted, specify the type of battery you installed. Verify that your tester is operating properly by navigating through a few menus. If the Batt LED is red, replace the batteries (see Replacing the batteries on page 93). If you suspect that the batteries are fine, and the batteries are fully charged, its possible the charger has detected a fault condition. See Resolving problems on page 96 for details.
The Ethernet Testers AC Adapter/Charger allows different AC line plug fittings. To change the AC line plug fitting 1 If an AC line plug fitting is already installed, do the following:
2 Press and hold the button just below the fitting. 3 Slide the fitting out of the slot. 4 Select the appropriate AC line plug adapter. 5 Slide the AC line plug adapter into the slot. You will hear a click when the fitting is fully inserted. The AC Adapter is ready for use.
Arrow keys OK key Cancel key Keypad (includes *Action and #Start keys) Backlight key Power key
Figure 1
The following paragraphs describe each of the controls and LEDs on the front panel.
Status LEDs
These indicators report the status of the tester. The function of each LED is described in LEDs on page 76.
LCD
The SmartClass Ethernet tester currently ships with a 320 x 240 pixel color display with contrast control and backlight. Older testers with the black and white 240 x 160 pixel transflective display are still supported, and software upgrades are available for these testers. Due to the lower resolution of the black and white display, in rare instances, the final character of a label on the user interface is not visible, or it is only partially visible. When this occurs, the text displayed is sufficient to communicate the purpose of the element on the user interface. This is expected behavior, and it does not occur on black and white displays of testers running software versions prior to 2.0.1.
Cancel key
Use the Cancel key to exit a data entry screen without changing your settings, or to return to the previous menu.
Use the keypad to enter numbers, make menu selections, enter alphabetic characters, and so on. Throughout the menus, the numbers associated with each function provide a quick way to perform tests with simple numerical sequences. Use the Action key to display a menu listing a variety of actions required during testing such as starting traffic or looping up a tester. Use the Start key to: Start your test and transmit traffic immediately after you configure your test. After starting the test, the tester automatically displays test results associated with your application. Stop traffic and freeze the display of test results.
Action key
Start key
Backlight key
Use the backlight key adjust the brightness on a color display, or if you have a black and white display, to turn the LCD backlight on or off or adjust the contrast. If you have a tester with a color display, pressing the button increases or decreases the brightness by a step. If you have a tester with a black and white display, pressing the button turns the backlight on or off. You can also adjust the contrast on your LCD by pressing and holding the backlight key, and then simultaneously pressing the right arrow (to increase contrast), or the left arrow (to decrease contrast).
Power key
Use the power key to turn power ON (see Powering ON your tester on page 9), put the tester into sleep mode, or turn power OFF (see Powering OFF your tester on page 9).
SFP Connector
RJ-45 Connector
Figure 2
Use the RJ-45 jack when connecting to 10/100/1000Base-T/TX electrical circuits. If your tester supports optical testing (see Software options on page 3), use the SFP jack to connect to 1000Base-X optical circuits using a JDSU-approved SFP. See Accessories on page 4 for a list of SFPs offered by JDSU. CAUTION: HAZARDOUS LIGHT EXPOSURE Do not look into the SFP connector when the tester is powered ON.
AC adapter port
Figure 3
When you power up the SmartClass Ethernet Tester, the Main Menu of the user interface appears. Figure 4 illustrates the Main Menu for a fully optioned tester with a color display.
Figure 4
Battery icon
A battery icon appears at the top right of each screen to indicate how much of a charge remains on your battery.
Table 5
Icon
Battery icons
Indicates ... The battery charge is greater than or equal to 5 volts.
10
Menu screens
Figure 5
Menu screens provide a series of selections that take you to another menu screen, a data entry screen, or a results screen. For example, if you select the L2 Traffic Test illustrated in Figure 5, the Configuration menu illustrated in Figure 6 appears, listing each of the available configuration screens.
Figure 6
11
Data entry screens provide a list of selectable options, or allow you to enter data using the keypad. Figure 7 illustrates the Save Config screen, used to specify a filename for a configuration that you are saving so you run tests using the same settings in the future.
Figure 7
Result screens
Figure 8
These screens display test results. The results are split into categories. Press the arrow keys to navigate through the result categories (screens).
12
There are two ways to select a menu option or configuration setting. Use the arrow keys to scroll to the desired option then press the OK key. Press the number associated with the menu option.
To enter numeric values 1 Use the arrow keys to scroll to and highlight the setting you want to specify. 2 Press OK. 3 Use the keypad to type the numeric value. 4 If you want to move to the next field, use the right arrow key. 5 If you want to enter a minus sign (-), and the setting accepts negative values, press the # key. 6 If you want to enter a decimal point, and the setting accepts floating decimal values, press the asterisk (*) key.
Typing text
To type text 1 Use the arrow keys to scroll to and highlight the setting you want to specify. 2 Press OK.
13
3 Use the keypad to type the text. Repeatedly pressing a key scrolls through the selections for that key. For example, repeatedly pressing the 2 key will scroll through A, B, C and 2. To toggle between upper and lower case, press the up arrow. To delete the previous character, press the down arrow. Use the left and right arrow to navigate through typed text. To enter a space between characters, press the 0 (zero) key once. To scroll through and select a special character such as: . @ / , - ? ! _ 1 press the 1 (one) key. NOTE You can not enter a space when specifying a filename.
You can lock your keypad at anytime to prevent unintentional key presses that might disrupt or end the test. To lock the keypad Press the Backlight key and 8 key simultaneously. A message appears indicating that the keypad is locked. The following exceptions occur: You can still use the Backlight key in combination with the left and right arrow keys to adjust the brightness on a color display. For details, see Backlight key on page 7. If you have a black and white display, you can still use the Backlight key to turn the LCD backlight on or off, or in combination with the left and right arrow keys to adjust the contrast. You can still turn the tester off by pressing the Power key continuously for 7 seconds. To unlock the keypad Press the Backlight key and 8 key simultaneously. A message appears indicating that the keypad is unlocked.
14
Chapter 2
Instrument Settings
2
This chapter describes how to configure the basic settings of the instrument. Topics discussed in this chapter include the following: Setting the language on page 16 Viewing software versions on page 16 Setting the date and time on page 16 Adjusting the contrast on page 17 Loading software upgrades on page 17 Enabling options on page 18 Verifying enabled options on page 18 Determining the specified battery type on page 18 Restoring factory defaults on page 18
15
The following procedure describes how to change the date or time format on your tester. To change the date or time format 1 Select System Settings from the Main Menu. 2 Select Set Time/Date Format.
16
3 Do one of the following: To change the format used to display the time, select Time Format, and then select the new format. To change the format used to display the date, select Date Format, and then select the new format. The format is changed.
The following procedure describes how to set the date or time. To set the date or time 1 Select System Settings from the Main Menu. 2 Select Set Time/Date. 3 Do one of the following: To set the time, select Set Time, and then enter the time. To set the date, select Set Date, and then enter the date. The date or time is set.
17
Enabling options
The following procedure describes how to enable software options. To enable software options 1 Select System Settings from the Main Menu, then select Set Options. 2 Use your keypad to enter the JDSU provided option code. 3 Press the OK key. The option is enabled.
18
Chapter 3
Ethernet Testing
3
This chapter provides task-based instructions for turning up and troubleshooting Ethernet service using the SmartClass Ethernet Tester. Topics discussed in this chapter include the following: About Ethernet testing on page 20 Cable diagnostics on page 20 Measuring optical power on page 21 Launching an Ethernet test application on page 22 Initializing the link on page 22 Specifying L2 test application settings on page 24 Transmitting layer 2 traffic on page 33 BER testing on page 34 Measuring service disruption time on page 34 Inserting errors or pause frames on page 35 Transmitting layer 2 patterns on page 35 Loopback testing on page 36 Starting or restarting a test on page 38 Stopping traffic on page 38 Running a timed test on page 38
19
Cable diagnostics
Before testing 10/100/1000 electrical Ethernet or IP, you can use the Ethernet Tester to examine the state of the cables used to transmit traffic on a 10/100/1000 electrical Ethernet circuit. Typically this involves out-of-service testing to determine the link status, the pair status of each MDI or MDI-X pair, the pair assignments for 1000M links, the polarity for each MDI pair, and the pair skew. If the link is inactive, you can also use the tester to determine the nature of the fault. For details on the test results associated with cable diagnostics, see Cable Diagnostics results on page 88.
20
To run cable diagnostics 1 Power on the Ethernet Tester, and connect it to the link. 2 On the Main Menu, select Electrical Ethernet or Electrical IP. A menu of test applications for testing 10/100/1000 Mbps electrical Ethernet appears. 3 Select the Cable Test. A message briefly appears stating that the tester is launching the test application, then a test menu appears. 4 Select Results, and then select one of the following: Link Status to determine whether or not the link is active, and, if so, what speed (line rate) is detected for traffic on the link. Cable Diagnostics to observe the link results associated with the diagnostics, such as the MDI/MDIX Status or Pair Skew. For details, see Cable Diagnostics results on page 88. Cable diagnostics are complete.
21
22
To initialize an Ethernet link 1 Launch your test application: For Ethernet tests, see Launching an Ethernet test application on page 22. For IP tests, see Launching an IP test application on page 42. 2 Select Configuration, and then select Link Settings. A menu of link initialization settings appears. 3 Specify values for the following:
Setting Auto Neg Parameters Enabled Disabled Description/Applicability Enables the tester to auto-negotiate its capabilities with a link partner. This setting is always available. NOTE: Auto-negotiation must be enabled when testing 1000 Mbps electrical Ethernet. During auto-negotiation, the tester advertises it is half or full duplex capable. Available if Auto-Neg is enabled. When testing electrical Ethernet, the tester advertises this as the maximum rate supported during auto-negotiation. Available if Auto-Neg is enabled. When testing optical Ethernet, during auto negotiation, the tester advertises this as its capability to support pause frames. Neither advertises it can not transmit or detect received pause frames. Both advertises the tester can transmit and detect received pause frames. Indicates whether you want the tester to detect or ignore received pause frames. Available only if Auto Neg is disabled and Duplex setting is Full. Indicates the speed supported (10 Mbps or 100 Mbps). Available only if Auto Neg is disabled for a 10/100 electrical test. Indicates whether half or full duplex traffic is supported. Available only if Auto Neg is disabled for an electrical test.
Half Full
10 100 1000
Pause Capability
Flow Control
On Off
Speed
10 100
Duplex
Half Full
23
Description/Applicability Indicates whether the RJ-45 port on your tester should operate as an MDI or an MDI-X (crossover) port. If you select Auto Sensing, the tester determines what type of port is connected at the far end of the link, and then configures the RJ-45 port on your tester to be compatible with the port on the far end. For example, if the port on the far end is a MDI port, your tester configures its RJ-45 port to operate as a MDI-X crossover port. Available only when configuring electrical tests. When testing optical Ethernet, the laser is automatically on by default. You can turn the laser off using this setting. Enter the quanta to be carried by transmitted pause frames. To determine the pause duration, the receiving device performs the following calculation: 10 Mbps electrical: Quanta x 51.2 ms 100 Mbps electrical: Quanta x 5.12 ms 1000 Mbps electrical and 1 GigE optical: Quanta x 512 ns
Laser Enable
On Off
Pause Quanta
User specified
4 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 5. 5 Verify that the Sync LED is green (indicating that the link is active). 6 Observe the Link Status results category for test results associated with link initialization (see Link Status results on page 78). The link is initialized.
24
When you specify L2 settings for one test application, your tester retains the settings if you run a different test application. For example, if you turn auto-negotiation OFF and flow control ON for a L2 Traffic Test, auto-negotiation will be OFF, and flow control will be ON by default when you run a L2 Pattern Test.
Before you transmit layer 2 traffic, you can specify the frame characteristics of the traffic, such as the frame type and frame length. You also specify the destination address, and optionally, the source address for the transmitted traffic. To specify Ethernet settings 1 If you havent already done so, launch a layer 2 test application (see Launching an Ethernet test application on page 22), and then establish a link (see Initializing the link on page 22). 2 On the Configuration menu, select Ethernet Settings, and then specify values for the following:
Setting Dest Addr Type Parameters Unicast - sends traffic to a single destination address and network device. Multicast - sends traffic to a single destination address which then distributes the frames to multiple network devices, each with its own destination address. Broadcast - sends traffic to all network devices on the link.
Dest MAC Addr (applicable only if you specified a Unicast or Multicast address type)
Type the address for Unicast or Multicast destinations. If you specified Unicast as the address type, the left most byte in the address defaults to 00. If you specified Multicast as the address type, the left most byte in the address defaults to 01. DIX 802.3 Undersized User Defined Jumbo Random. Select Random to send frames with randomly generated, predefined RFC 2544 traffic lengths.
If you specified Undersized, User Defined, or Jumbo as the Frame Length, specify a value falling within the range displayed on the user interface.
25
Parameters Default - sends traffic with the factory assigned MAC address as the source address. User Defined - sends traffic with the user assigned MAC address as the source address. If you select User Defined, be certain to specify the Usr Src Addr.
Type the source address to be carried in transmitted frames. Enter an ID for the tester using up to ten characters. This ID appears in the Link Status result category during loopback testing.
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that traffic has started. The tester transmits traffic with the frame characteristics you specified.
Before you transmit layer 2 traffic, you can specify whether the traffic should carry a BERT payload or an Acterna payload. You must transmit an Acterna payload to measure round trip delay or service disruption time. To specify payload settings 1 If you havent already done so, launch a layer 2 test application (see Launching an Ethernet test application on page 22), and then establish a link (see Initializing the link on page 22). 2 On the Configuration menu, select Payload Settings, and then specify values for the following:
Setting Payload Parameter Acterna BERT NOTE: If you indicated that you want to transmit undersized frames when you specified the Ethernet settings, you can not transmit an Acterna payload. Enter the fill byte pattern carried in the payload of the Acterna test packets using a hexadecimal format.
26
Parameter 2^23-1 2^23-1 Inv 2^31-1 2^31- Inv All Ones All Zeros User Defined, and then enter the pattern in hexadecimal format.
User BERT Patt (applicable only if you specified a User Defined BER pattern).
Enter the BERT pattern carried in the payload of the frames in hexadecimal format.
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that traffic has started. The tester transmits traffic with the payload you specified.
Before transmitting layer 2 traffic, you can specify settings that indicate the tester should transmit VLAN (virtual LAN) or Q-in-Q tagged frames. This allows you to verify that an Ethernet link supports VLAN or Q-in-Q tagging. The tester can also analyze received traffic to verify that the required bandwidth is allocated to tagged frames on a link and determine that VLAN or Q-in-Q (SVLAN) prioritization is functioning properly. To specify VLAN or Q-in-Q settings 1 If you havent already done so, launch a layer 2 test application (see Launching an Ethernet test application on page 22), and then establish a link (see Initializing the link on page 22). 2 On the Configuration menu, select Tagging Settings, and then specify values for the following:
Setting Tagging Parameters If you do not want to transmit VLAN tagged frames, select Non-Tagged. To transmit VLAN tagged frames, select Tagged, and then specify the VLAN ID and User Priority for the tagged frames. To transmit Q-in-Q tagged frames, select Q-in-Q, and then specify the SVLAN ID, Priority, DEI, and TPI for the frames.
Specify the VLAN ID for tagged frames, or the CVLAN ID for Q-in-Q tagged frames.
27
Setting User Priority (available if Tagging is set to Tagged or Q-in-Q) SVLAN ID (available if Tagging is set to Q-in-Q) SVLAN Priority (available if Tagging is set to Q-in-Q) SVLAN DEI (available if Tagging is set to Q-in-Q) SVLAN TPI (available if Tagging is set to Q-in-Q)
Parameters Specify the priority for the tagged frames, or the CVLAN priority for Q-in-Q tagged frames. Specify the SVLAN ID for the frames. Specify the SVLAN priority for the frames. Specify the SVLAN DEI for the frames. Specify the SVLAN TPI for the frames.
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that the test has started. The tester transmits traffic with the VLAN or Q-in-Q settings you specified.
Before transmitting traffic, you can specify the type of traffic load the tester will transmit (Constant, Bursty, Ramp, or Flood) in 0.001% increments. The settings vary depending on the type of load. NOTE: If you configure the Ethernet Tester to transmit a constant, bursty, or ramped load of 100%, the tester is designed to transmit slightly less than 100% traffic (99.99% for 1G optical Ethernet, 99.98% for 10/100/1000 electrical Ethernet) as a safeguard against overrunning network elements that can not support 100%. If you are certain the elements can support true 100% traffic, configure your tester to transmit a flood load (see Transmitting a flooded load on page 31).
With a constant load, the Ethernet Tester transmits frames continuously with a fixed bandwidth. See Figure 9.
Figure 9
Constant traffic
When you setup a constant traffic load, you can specify the bandwidth as a percentage of the line rate (Percent) or in total Mbps (Bit Rate). 28 SmartClass Ethernet Tester Users Guide
To transmit a constant load of traffic 1 If you havent already done so, launch a layer 2 test application (see Launching an Ethernet test application on page 22), and then establish a link (see Initializing the link on page 22). 2 On the Configuration menu, select Traffic Settings, and then specify values for the following settings:
Setting Load Type Load Unit Load Percent (if Load Unit is Percent) Load Bit Rate (Mbps) (if Load Unit is Bit Rate) Parameters Constant Percent Bit Rate
Enter the bandwidth to transmit as a percentage of the line rate. Enter the bandwidth to transmit in Mbps.
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that traffic has started. The tester transmits a constant rate of traffic. Transmitting a bursty load With a bursty load, the tester transmits frames at up to 100% bandwidth for a specific time interval, followed by no frame transmissions for an interval (gap) calculated by your tester. See Figure 10.
Gap between bursts
100%
Bandwidth Time
29
2 On the Configuration menu, select Traffic Settings, and then specify values for the following settings:
Setting Load Type Burst Load % Parameters Burst Enter the load to transmit during bursts as a percentage of the line rate. Select the number of frames to transmit in each burst of traffic, or select User Defined. If you selected a User Defined burst size, enter the number of frames to transmit in each burst of traffic, ranging from 1 to 16,500,000. Select Fixed to specify a fixed number of bursts, or select Continuous. If you specify a Fixed Burst Type, enter the number of bursts to transmit, ranging from 1 to 65,535.
Burst Size
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that traffic has started. The tester transmits a bursty load of traffic. Transmitting a ramped load With a ramped load, the Ethernet Tester gradually ramps (increases) the transmitted traffic load by 1 percent every 1 second until it detects errored, dropped, or pause frames. This allows you to easily verify the maximum throughput of a link. When you verify throughput by transmitting a ramped load, be certain to configure your tester to transmit an Acterna payload, and loop the far-end device back to the traffic originating tester (see Using the automatic loopback feature on page 37). Acterna frames carry a number which the tester uses to determine whether frames were dropped.
30
The load increments to 100%, and then the tester continues to transmit traffic at 100% for the duration of your test. See Figure 11.
Time
31
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that traffic has started. The tester transmits a flooded load of traffic.
Before transmitting layer 2 traffic, you can specify settings that indicate the expected received payload and determine which frames will pass through the receive filter and be counted in the test result categories for layer 2 traffic. For example, if you specified a particular VLAN ID as filter criteria, only incoming frames for the VLAN you specified will pass the filter and be analyzed. Local loopback will also only be performed on frames that pass the filter. NOTE: If you want to analyze all received traffic, verify that each of the filter settings is set to Dont Care. To specify filter settings 1 If you havent already done so, launch a layer 2 test application (see Launching an Ethernet test application on page 22), and then establish a link (see Initializing the link on page 22). 2 On the Configuration menu, select Ethernet Filter, and then specify values for the following settings:
Setting Rx DA Type Parameters To analyze frames for a specific type of destination address, select: Unicast Multicast Broadcast If you do not want to filter frames based on the destination address type, select: Dont Care To analyze frames sent to a specific Unicast or Multicast address, enter the destination address. To analyze frames sent from a specific address, select: Unicast If you do not want to filter frames sent from a specific address, select: Dont Care To analyze frames sent from a specific address, enter the source address.
32
Setting Rx Tagging
Parameters To analyze VLAN tagged frames, select: Tagged, and then specify the VLAN ID and user priority for the filtered frames. To analyze Q-in-Q tagged frames, select: Q-in-Q, and then specify the SVLAN ID, priority, and TPI for the filtered frames. If you do not want to filter frames based on their tagged status, select: Dont Care To filter VLAN tagged frames based on their user priority: Select the priority from the menu. If you do not want to filter frames based on their user priority, select: Dont Care Specify the VLAN ID for analyzed frames.
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that the test has started. The tester filters traffic using the settings you specified.
33
BER testing
If you are testing on a switched Ethernet network, when you perform an end-to-end test you can transmit BERT patterns in the frame payload to determine the ratio of erroneous bits to the total bits received. To transmit a BER pattern 1 If you havent already done so, launch a layer 2 test application (see Launching an Ethernet test application on page 22), and then establish a link (see Initializing the link on page 22). 2 On the Configuration menu, select Payload Settings, specify a BERT payload, and then select the pattern to transmit in the payload (see Specifying payload settings on page 26 3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that the test has started. 5 Verify that the Frame LED is green, indicating that frames have been detected. 6 Optional. If you want to insert a bit error, press the Action key, and then select Insert Bit Error. The tester transmits traffic with the BERT pattern in the payload over the link. Results associated with BER testing appear in the BERT results category (see L2 BERT Stats results on page 87).
34
The tester measures service disruption time, and displays the measurement as the Service Disrupt(s) result in the Link Stats category (see Link Stats results on page 81).
35
Pattern CJPAT
Emulates Stress the timing margins in the received eye by exposing the data sampling circuits to large systematic phase jumps. Emulate a worse case scenario for power supply noise within network transceivers.
CSPAT
3 If you need to specify other settings for the test (such as enabling a timed test or turning the laser off), press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that the test has started. 5 Verify that the Frame LED is green, indicating that frames have been detected. The tester transmits the pattern.
Loopback testing
Depending on the software options loaded on your Ethernet Tester, you can: Operate the tester as a loopback device (looping all received traffic through the tester and back to the traffic originating tester) using the dedicated L2 Loopback application. This application is provided standard with every Ethernet Tester. Generate and loop back traffic using the L2 Traffic application for end-toend testing. The TRAFFIC option must be purchased and installed to generate and loop back traffic using this application.
You can put your Ethernet Tester into loopback mode to loop traffic through the tester and back to a traffic originating tester. When you select this application, your tester simply operates as a loopback device. To loop traffic through your near end tester 1 Launch the L2 Looback application (see Launching an Ethernet test application on page 22), and then establish a link (see Initializing the link on page 22). 2 On the Configuration menu, select Ethernet Settings, and then specify values for the following:
Setting Src MAC Type Parameters Factory Default - loops back traffic with the factory assigned MAC address as the source address. User Defined - loops back traffic with a user assigned MAC address as the source address. If you select User Defined, be certain to specify the Usr Src Addr.
36
3 Optional. You can optionally specify VLAN or Q-in-Q settings for looped back traffic. See Specifying VLAN or Q-in-Q settings on page 27. 4 Optional. You can optionally filter the traffic before looping it back. Only traffic that passes the filter criteria will be looped back to the traffic originating tester. See Specifying Ethernet filter settings on page 32. 5 Press the Action key, and then select Enable LLB. A message appears indicating that the LLB action has been executed. To verify that the local loopback is up, check the LLB Status result in the Link Status category (see Viewing test results on page 76). 6 On the far end tester, specify the near end testers source MAC address as the destination address, and then transmit traffic over the link. When the near end tester receives the traffic, it will swap the destination address and the source address of every frame before looping them back to the transmitting tester. 7 On the near end tester, verify that the Frame LED is green, indicating that frames have been detected. Traffic is looped through your tester.
You can perform an automatic loopback by selecting the Loop Up action on the traffic generating tester. The destination address for traffic generated by the near end tester is automatically populated with the source MAC address of the tester on the far end. When you configure testers for an automatic loopback test, you can optionally specify text identifiers for each tester using up to ten characters (for example, tester 001 and tester 002). The LLB ID appears in the Link Status result category. To perform an automatic loopback 1 On the near end tester, do the following: a Launch a layer 2 test (see Launching an Ethernet test application on page 22). b Establish a link (see Initializing the link on page 22). c Specify the settings for the traffic you will be looping through the tester on the far end (see Specifying L2 test application settings on page 24). 2 On the near end tester, press the Action key, and then do the following: a Select Loop Up to loop up the tester on the far end. A message appears indicating that the Loop Up action has been executed. b Observe the Link Status results to verify that the remote loop status is UP (see Viewing test results on page 76). c Select Start Traffic to transmit traffic to the far end.
37
3 On the far end tester, verify that the Frame LED is green, indicating that the frames transmitted from the near end tester have been detected. Traffic is transmitted and looped through the tester on the far end. To loop down the far end tester 1 On the near end tester, press the Start key to stop traffic. 2 Press the Action key, and then select Loop Down. The tester on the far end is looped down, and the remote loop status in the Link Status results changes to DOWN.
Stopping traffic
To stop traffic Press the # Start key. NOTE: The Start key is used to START and STOP traffic. The tester stops transmitting traffic and freezes the results display.
38
To run a timed test 1 If you havent already done so, launch your test application (see Launching an Ethernet test application on page 22), initialize the Ethernet link (see Initializing the link on page 22), and configure the test (see Specifying L2 test application settings on page 24). 2 On the Configuration menu, select Timed Test, and then do the following: a Set the Timed Test Enable setting to ON. b Specify the Time Duration (sec) in seconds. 3 Press the Start key to run the test.
39
40
Chapter 4
IP Testing
4
This chapter provides task-based instructions for turning up and troubleshooting IP service using the SmartClass Ethernet Tester. Topics discussed in this chapter include the following: About IP testing on page 42 Launching an IP test application on page 42 Initializing the Ethernet link on page 43 Specifying L3 test application settings on page 43 Transmitting layer 3 IP traffic on page 48 Inserting errors or pause frames on page 49 Loopback testing on page 49 Ping testing on page 52 Running TraceRoute on page 54 Starting or restarting a test on page 55 Stopping traffic on page 55
41
About IP testing
Using the SmartClass Ethernet Tester, you can turn up and troubleshoot IP services on point-to-point unswitched and switched networks by verifying connectivity, measuring throughput, and verifying that quality of service statistics conform to those specified in a customers Service Level Agreement. Before running IP tests, consider the following: If you are preparing to run an electrical IP test, you can optionally run cable diagnostics to determine the type of cable used to connect to the circuit (see Cable diagnostics on page 20). If you are preparing to run an optical IP test, you can determine whether a signal is present, the optical receive level (in dBm), and the type of SFP you are using (see Measuring optical power on page 21). IP testing involves the following key steps: 1 Launching a test application (see Launching an IP test application on page 42). 2 Initializing the Ethernet link (see Initializing the link on page 22). 3 Specifying settings for the test application (see Specifying L3 test application settings on page 43). 4 Starting or restarting the test (see Starting or restarting a test on page 38). 5 Observing the results associated with your test (see Viewing test results on page 76).
42
A message briefly appears stating that the tester is launching the test application, then a test menu appears for the application, listing the following options: Configuration. Select this option to configure your test. Results. Select this option to observe test results associated with your test. Action (*). Select this option to perform key actions required for your test, such as starting or restarting a test, starting traffic or looping up a tester. You can also press the Action button at any time to view a menu of actions applicable to your test. Error. Select this option to insert errors or pause frames as you test. The tester launches the test application, and if you selected an optical test application, turns the laser ON. You are ready to initialize the Ethernet link (see Initializing the Ethernet link on page 43).
Before you transmit layer 3 IP traffic, you can specify the Ethernet characteristics of the traffic. This involves indicating whether you want to configure transmitted traffic using a frame or packet format, and specifying the frame type and frame or packet length. You can also optionally specify the source address for the transmitted traffic. To specify Ethernet settings 1 If you havent already done so, launch a layer 3 test application (see Launching an IP test application on page 42), and then establish a link (see Initializing the link on page 22). 2 On the Configuration menu, select Ethernet Settings, and then specify values for the following:
Setting Frame Type Length Type Parameters DIX 802.3 Frames Packets
43
Parameters User Defined Jumbo Random. Select Random to send frames with randomly generated, predefined RFC 2544 traffic lengths.
If you specified User Defined or Jumbo as the Frame Length, specify a value falling within the range displayed on the user interface. Default - sends traffic with the factory assigned MAC address as the source address. User Defined - sends traffic with the user assigned MAC address as the source address. If you select User Defined, be certain to specify the Usr Src Addr.
Type the source address carried in transmitted frames. Enter an ID for the tester using up to ten characters. This ID is used to identify the tester during loopback testing.
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that the test has started. The tester transmits traffic with the characteristics you specified.
Before you transmit layer 3 traffic, you can specify whether the traffic should carry an Acterna, or Fill Byte payload. You must transmit an Acterna payload to measure round trip delay, service disruption time, or out of sequence frames. To specify payload settings 1 If you havent already done so, launch a layer 3 test application (see Launching an IP test application on page 42), and then establish a link (see Initializing the Ethernet link on page 43). 2 On the Configuration menu, select Payload Settings, and then specify values for the following settings:
Setting Payload Fill Byte Parameter Acterna Fill Byte
Enter the fill byte pattern carried in the payload using a hexadecimal format.
44
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that the test has started. The tester transmits traffic with the payload you specified.
Before transmitting layer 3 traffic, you can specify settings that indicate the tester should transmit VLAN (virtual LAN), Q-in-Q, or MPLS tagged traffic. This allows you to verify that an Ethernet link supports the encapsulated traffic. The tester can also analyze received traffic to verify that the required bandwidth is allocated to tagged traffic on a link and determine that VLAN, Q-in-Q (SVLAN), or MPLS prioritization is functioning properly. For details on VLAN and Q-in-Q tagging, see Specifying VLAN or Q-in-Q settings on page 27 of Chapter 3 Ethernet Testing. To specify MPLS settings 1 If you havent already done so, launch a layer 3 test application (see Launching an IP test application on page 42), and then establish a link (see Initializing the link on page 22). 2 On the Configuration menu, select Tagging Settings, and then specify values for the following:
Setting Tagging MPLS EtherType Parameters Select MPLS. Select one of the following: Unicast Multicast Indicate whether you want to transmit traffic tagged with one or two MPLS labels. The network will use the label(s) to route the traffic. NOTE: The MPLS 2 settings only appear if you indicate that you want to tag the traffic with two labels. Specify the label ID. Specify the label priority. Specify the time to live (TTL).
MPLS 1 ID MPLS 2 ID MPLS 1 Priority MPLS 2 Priority MPLS 1 TTL MPLS 2 TTL
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that the test has started. The tester transmits traffic with the MPLS settings you specified.
45
Before transmitting layer 3 traffic, you can specify the type of traffic load the tester will transmit (Constant, Bursty, Ramp, or Flood) in 0.001% increments. The settings vary depending on the type of load. For details on traffic loads, see Configuring the traffic load on page 28 of Chapter 3 Ethernet Testing.
Specifying IP settings
Before transmitting layer 3 traffic, you should specify settings that indicate whether the tester has static or DHCP-assigned source IP, subnet, and gateway addresses. To specify IP settings 1 If you havent already done so, launch a layer 3 test application (see Launching an IP test application on page 42), and then establish a link (see Initializing the Ethernet link on page 43). 2 On the Configuration menu, select IP Settings, and then specify values for the following settings:
Setting ARP Mode Parameter Select one of the following: If you want the unit to issue an ARP request to determine the destination MAC address of the testers link partner, select Enabled. If you want to manually specify the destination MAC address (see Specifying Ethernet settings on page 25), select Disabled. NOTE: This setting is not available if you configured the traffic with MPLS tagging. Select one of the following: If you want the unit to issue an ARP request to determine the destination MAC address of the testers link partner, select Enabled. If you enable ARP, you must specify the source IP address for this hop, and the destination IP and subnet addresses for the next hop. If you want to manually specify the destination MAC address (see Specifying Ethernet settings on page 25), select Disabled. NOTE: This setting is not available if the traffic is not configured using MPLS tagging. Enter the destination IP address for traffic transmitted by your tester. Select one of the following: Static - allows you to manually specify the IP, subnet, and gateway addresses. DHCP - allows a DHCP server to assign an IP address to the tester. You can not use DHCP if your traffic is configured using MPLS tagging. If the source IP type is Static, enter the source IP address for traffic generated by your tester.
Source Addr
46
Parameter If the source IP type is Static, enter the subnet mask address for traffic generated by your tester. If the source IP type is Static, enter the default gateway address. Specify the source IP address for this hop.
Default Gateway This Hop Source IP (MPLS ARP Mode is Enabled) Next Hop Dest IP (MPLS ARP Mode is Enabled) Next Hop Subnet (MPLS ARP Mode is Enabled) Time To Live
Specify the destination IP address for the next hop. Specify the subnet address for the next hop.
Specify the time after which a packet can be deleted by any device on a circuit as a number of hops. The default time to live setting is 64 hops. Enter the type of service in binary format.
TOS
3 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 4. 4 Press the Start key. A message appears indicating that the test has started. The tester transmits traffic with the settings you specified.
If you launched the L3 Traffic test, before transmitting traffic, you can specify settings that determine which frames or packets will pass through the receive filter and be counted in the test result categories for layer 3 IP traffic. NOTE: If you want to analyze all received traffic, verify that the Ethernet Filter and IP Filter settings are all Dont Care. To filter received layer 3 IP traffic 1 If you havent already done so, launch a layer 3 test application (see Launching an IP test application on page 42), and then establish a link (see Initializing the link on page 22). 2 If you want to filter traffic using layer 2 criteria, on the Configuration menu, select Ethernet Filter, and then specify the layer 2 settings; otherwise, proceed to step 3. For details, see Specifying Ethernet filter settings on page 32 of Chapter 3 Ethernet Testing.
47
3 If you want to filter traffic using source IP, source subnet, destination IP, or destination subnet address criteria, on the Configuration menu, select IP Filter, enable the filter, and then specify values for the following:
Setting Src IP Filter Parameter Select Yes if you want to filter received traffic using source IP address criteria; otherwise, select Dont Care. Enter the source address for filtered traffic. Select Yes if you want to filter received traffic using source subnet address criteria; otherwise, select Dont Care. Enter the prefix length of the source subnet address for filtered traffic. Select Yes if you want to filter received traffic using destination IP address criteria; otherwise, select Dont Care. Enter the destination address for filtered traffic. Select Yes if you want to filter received traffic using destination subnet address criteria; otherwise, select Dont Care. Enter the prefix length of the destination subnet address for filtered traffic. Select Yes if you want to filter received traffic using TOS value criteria; otherwise, select Dont Care. Enter the DSCP value for filtered traffic.
4 If you need to specify other settings for the test, press Cancel to return to the Configuration menu; otherwise, proceed to step 5. 5 Press the Start key. A message appears indicating that the test has started. The tester transmits traffic with the settings you specified.
3 Do one of the following: Press the Start key. Press the Action key, and then select Start Traffic or Start Ramp. A message appears indicating that traffic has started. The tester transmits traffic over the link.
Loopback testing
Depending on the software options loaded on your Ethernet Tester, you can: Operate the tester as a loopback device (looping all received traffic through the tester and back to the traffic originating tester) using the dedicated L3 Loopback application. This application is provided standard with every Ethernet Tester. Generate and loop back traffic using the L3 Traffic application for end-toend testing. The TRAFFIC option must be purchased and installed to generate and loop back traffic using this application. Both testers must reside on the same segment (subnet) of the circuit.
49
When looping back MPLS encapsulated traffic, labels are handled as follows: Before received traffic is passed through to the loopback units transmitter, the labels for the received traffic are automatically replaced with the labels specified for traffic transmitted from the loopback unit; therefore: If your local unit is configured to transmit traffic with a second MPLS label, but the loopback unit is configured to transmit traffic with a single label, the out of sequence and lost frames counts reported by the local unit may increment if the incoming frame rate is too high. If your local unit is configured to transmit traffic with a single MPLS label, but the loopback unit is configured to transmit traffic with a second label, the local units receive bandwidth utilization will exceed its transmitted bandwidth utilization. If you are looping back multiple streams of MPLS traffic, you can specify unique labels for each individual stream, or you can specify the labels for one stream, and then copy them to the other streams. Destination addresses are handled as follows: If you initiate a loopback from a local unit using the Loop Up button, and ARP is enabled on both units, you must specify the destination IP address and subnet mask for the next hop on the circuit. If both units are capable of transmitting traffic (in other words, neither unit is configured to be used as a dedicated loopback unit), and you use the LLB button on the loopback unit to loop traffic back to the local unit: If ARP is enabled on both units you must manually specify the destination IP addresses for the traffic transmitted from the local unit and for the traffic looped back by the loopback unit. If ARP is disabled on both units, you must also specify the destination MAC address for traffic transmitted by the local unit. If the loopback unit is a configured as a dedicated loopback tester, MPLS encapsulation must be enabled on the loopback unit, and the labels for the received traffic will automatically be replaced with the MPLS labels specified for the loopback unit.
You can put your Ethernet Tester into loopback mode to loop traffic through the near end tester and back to a traffic originating tester. When you select this application, your tester simply operates as a loopback device. To loop traffic through your near end tester 1 Launch the L3 Loopback Mode test (see Launching an IP test application on page 42), and then establish a link (see Initializing the link on page 22). 2 Optional. You can optionally filter the traffic before looping it back. Only traffic that passes the filter criteria will be looped back to the traffic originating tester. See Filtering received layer 3 traffic on page 47. 3 Press the Action key, and then select Enable LLB. A message appears indicating that the LLB action has been executed. To verify that the local loopback is up, check the LLB Status result in the Link Status category (see Viewing test results on page 76).
50
4 On the far end tester, at a minimum, specify the near end testers source IP address as the destination IP address, and then transmit traffic over the link. Use the options on the Configuration menu to specify settings for the traffic to be looped back. See Specifying L3 test application settings on page 43 On the near end tester, verify that the Frame LED is green, indicating that frames or packets have been detected. When the near end tester receives the traffic, it will: Swap the destination MAC and IP address and the source MAC and IP address of every frame or packet. If it receives layer 4 traffic, the tester will also swap the source and destination port numbers. Loop the traffic back to the far-end, traffic originating tester. Traffic is looped through your tester.
You can perform an automatic loopback by selecting the Loop Up action on the traffic generating tester. The destination address for traffic generated by the near end tester is automatically populated with the source MAC and IP address of the tester on the far end. When you configure testers for an automatic loopback test, you can optionally specify text identifiers for each tester using up to ten characters (for example, tester 001 and tester 002). The LLB ID appears in the Link Status result category. To perform an automatic loopback 1 On the near end tester, do the following: a Launch the L3 Traffic test (see Launching an IP test application on page 42). b Establish a link (see Initializing the link on page 22). c Specify the settings for the traffic you will be looping through the tester on the far end (see Specifying L3 test application settings on page 43). 2 On the near end tester, press the Action key, and then do the following: a Select Loop Up to loop up the tester on the far end. b Observe the Link Status results to verify that the remote loop status is UP (see Viewing test results on page 76). c Select Start Traffic to transmit traffic to the far end. 3 On the far end tester, verify that the Frame LED is green, indicating that the frames or packets transmitted from the near end tester have been detected. Traffic is transmitted and looped through the tester on the far end.
51
To loop down the far end tester On the near end tester, press the Action key, and then select: Stop Traffic Loop Down The tester on the far end is looped down, and the remote loop status in the Link Status results changes to DOWN.
Ping testing
Using the Ethernet Tester, you can verify connectivity with another Layer 3 or IP device by sending ping request packets to the device. The device then responds to the ping request with a ping reply (if the device is responsive). Ping testing tells you if the destination device is responsive, how long it took the ping packet to travel to the destination device and back to the Ethernet Tester, and if ping packets were dropped or lost along the way. To send ping packets to another Ethernet device 1 Launch the Ping test (see Launching an IP test application on page 42), and then establish a link (see Initializing the link on page 22). 2 Optional. Specify the VLAN or Q-in-Q settings for the ping traffic (see Specifying VLAN or Q-in-Q settings on page 27). 3 On the Configuration menu, select Ping Settings, and then do the following: a Specify values for the following settings:
Setting Dest Addr Source Type Parameter Enter the destination IP address of the device you are pinging. Source Addr Subnet Mask Default Gateway Tx Size TOS Static - allows you to manually specify the IP, subnet, and gateway addresses. DHCP - allows a DHCP server to assign an IP address to the tester.
If the source IP type is Static, enter the source IP address for traffic generated by your tester. If the source IP type is Static, enter the subnet mask address for traffic generated by your tester. If the source IP type is Static, enter the default gateway address. Enter the size of the ping packet(s) transmitted, ranging from 46 to 1500 bytes. Enter the type of service in binary format.
52
Specify the time after which a ping request or response can be deleted by any device on a circuit as a number of hops. The default time to live setting is 64 hops.
b Press Cancel to return to the Configuration menu. 4 On the Configuration menu, select Traffic Settings, and then do the following: a Specify values for the following settings:
Setting Ping Type Parameter Specify how you want the tester to transmit pings: Single - To send a single ping packet, select Single. Multiple - To send a fixed number of ping packets, select Multiple, and then type the number of packets. The minimum number of packets is 2; the maximum number of packets is 1024. Continuous - To send a continuous stream of ping packets at 1 second intervals, select Continuous. PING_FAST - To send a continuous stream of ping packets at up to 100 ms intervals, select PING_FAST. The tester will attempt to send pings packets at a rate of once every 100 ms; assuming a response is received within 100 ms. If the unit doesnt receive a reply within 100 ms, it will wait up to one additional second for a reply. If a reply is received, it will then send another ping packet. Therefore, this setting may result in very fast ping transmissions, or slower transmissions, depending on the responsiveness of the network. Enter the number of ping packets to transmit.
b Press Cancel to return to the Configuration menu. 5 To transmit a ping packet or packets, do one of the following: Press the Start button. Press the Action key, and then select Start Ping. The Ethernet Tester transmits the ping packet or packets. Results associated with Ping testing appear in the Ping Stats results category (see Ping Stats results on page 88).
53
Running TraceRoute
You can run the traceroute test to determine where problems in the network are occurring. Before running traceroute, you specify settings such as the destination IP address, the maximum number of hops, and the response time. To run traceroute 1 Launch the TraceRoute test (see Launching an IP test application on page 42), and then establish a link (see Initializing the link on page 22). 2 Optional. Specify the VLAN or Q-in-Q settings for the traffic (see Specifying VLAN or Q-in-Q settings on page 27). 3 On the Configuration menu, select TR Settings, and then do the following: a Specify values for the following:
Setting Dest Addr Source Type Parameter Enter the destination IP address of the device you are tracing the route to. Source Addr Subnet Mask Default Gateway Frame Type Time To Live Static - allows you to manually specify the IP, subnet, and gateway addresses. DHCP - allows a DHCP server to assign an IP address to the tester.
If the source IP type is Static, enter the source IP address for traffic generated by your tester. If the source IP type is Static, enter the subnet mask address for traffic generated by your tester. If the source IP type is Static, enter the default gateway address. DIX 802.3
Specify the time after which a fragmented packet can be deleted by any device on a circuit as a number of hops. The default time to live setting is 64 hops. Specify the time in seconds after which the tester will abort the trace if it does not receive a response from a hop. Enter the type of service in binary format.
Timeout (sec)
TOS
b Press Cancel to store the settings and return to the Configuration menu. 4 To start tracing the route, do one of the following: Press the Start button. Press the Action key, and then select Start TraceRoute. The Ethernet Tester traces the route. Results associated with traceroute testing appear in the TraceRoute Log results category (see TraceRoute Log results on page 88).
54
Stopping traffic
For details on stopping traffic, see Stopping traffic on page 38 of Chapter 3 Ethernet Testing.
55
56
Chapter 5
5
This chapter provides step-by-step instructions for transmitting and analyzing multiple streams of Ethernet or IP traffic using the Ethernet Tester. Topics discussed in this chapter include the following: About multiple streams testing on page 58 Launching a multiple streams test application on page 58 Initializing the link for multiple streams on page 59 Specifying common stream settings on page 60 Enabling traffic streams and configuring the load on page 61 Configuring individual traffic streams on page 61 Copying a streams settings to all streams on page 63 Transmitting multiple streams on page 63 Loopback testing on page 63 Viewing test results for a stream on page 64
57
58
Chapter 5 Multiple Streams Testing Initializing the link for multiple streams
Source IP Type
L3 Streams
Source IP
L3 Streams, ARP Disabled, Source IP Type is Static L3 Streams, ARP Disabled, Source IP Type is Static L3 Streams, ARP Disabled, Source IP Type is Static
Subnet Mask
Default Gateway
If the source IP type is Static, enter the default gateway address for all enabled streams.
The link initialization settings are specified. You are ready to specify the common settings shared by all enabled traffic streams.
59
L2 Streams
Specify one of the following: Default - Select Default to use the factory default MAC address. User Defined - Select User Defined if you want to specify your own source MAC address for the streams. Specify the source MAC address for the streams.
L2 and L3 Streams with SRC MAC Mode set to Single, and SRC MAC Type set to User Defined L2 and L3 Streams L2 and L3 Streams
Specify the unit identifier carried in the streams. Specify the Fill Byte pattern carried in the ATP payload of the streams. Specify the stream number that you intend to insert errors into. You can only insert errors into a single stream at a time. NOTE: More than one stream must be enabled on the Traffic Settings screen to activate this setting.
L2 and L3 Streams
60
Chapter 5 Multiple Streams Testing Enabling traffic streams and configuring the load
To enable a particular stream, select Yes; otherwise, select No. If you indicated that the load unit was a percent of the line rate, specify the percent carried by this particular stream. The total percentage for all enabled streams can not exceed 100%. If you indicated that the load unit was a bit rate, specify the rate carried by this particular stream in Mbps. The total rate for all enabled streams can not exceed the line rate for the circuit you are testing.
The traffic streams are enabled, and the load is configured. Proceed to Configuring individual traffic streams. TIP: You can quickly distribute the traffic load equally for all enabled streams by pressing *Action, and then selecting Distribute Load. For example, if you enabled Stream 1, and specified a load of 1000 Mbps, then enable Stream 2, you can quickly distribute the load evenly using the Distribute Load action. Each stream will be configured for a 500 Mbps load.
If you indicated that you want to specify a unique source MAC or IP address to each enabled stream, you do so when you configure the stream. To configure a specific traffic stream 1 Select Configuration, and then select Stream X where X represents the number of the stream you are want to configure. A menu of settings that will apply to that specific stream appears. 2 Select Ethernet Settings, and then specify the Ethernet settings: If you launched a L2 Streams test, refer to Specifying Ethernet settings on page 25. If you launched a L3 Streams test, refer to Specifying Ethernet settings on page 43. 3 If you launched a L3 Streams test, select IP Settings, and then specify values for the following:
Setting Dest IP Source IP Applicability L3 Streams L3 Streams, Source IP Type is Static Per Stream L3 Streams, Source IP Type is Static Per Stream L3 Streams, Source IP Type is Static Per Stream L3 Streams Parameter Enter the destination IP address for traffic transmitted by your tester. Enter the source IP address for this particular stream.
Subnet Mask
Default Gateway
Time To Live
Specify the time after which a packet can be deleted by any device on a circuit as a number of hops. The default time to live setting is 64 hops. Enter the type of service in binary format.
TOS
L3 Streams
4 Select Tagging Settings, and then specify the settings used to encapsulate the traffic in the stream. For details, see Specifying VLAN or Q-in-Q settings on page 27. 5 If you want to manually configure additional streams, repeat step 2 through step 4 for each enabled stream; otherwise, refer to Copying a streams settings to all streams on page 63. The traffic streams are configured.
62
Loopback testing
Loopback testing allows you to transmit multiple streams of Ethernet or IP traffic from one Ethernet Tester (or another JDSU Ethernet test set), and then loop the streams back through a second unit on the far end of a circuit. When looping back multiple streams of traffic, if an enabled stream does not successfully loop, the unit will not loop up the remaining streams. For example, if you are trying to loop up a series of four enabled streams, and stream one and stream two successfully loop, but stream three fails, the unit will not loop up stream three or stream four. For step-by-step instructions, see Loopback testing on page 36 of Chapter 3 Ethernet Testing or Loopback testing on page 63 of Chapter 4 IP Testing.
63
64
Chapter 6
6
This chapter describes the automated RFC 2544 tests. Topics discussed in this chapter include the following: About RFC 2544 testing on page 66 Running an RFC 2544 test on page 67 Viewing the RFC 2544 log on page 70
65
The standard RFC 2544 test is useful if the uplink and downlink speeds on the circuit you are testing are the same. When running this test, the tester on the near-end loops up a tester on the far end, then transmits traffic which is looped back to the near end.
The new RFC 2544 test is useful if the uplink and downlink speeds on the circuit are different (as illustrated in Figure 13 on page 67). The test can be run end-to-end; no loopback is required. When you configure the test, you indicate that you are testing Upstream or Downstream. Upstream - If you are testing Upstream, the master tester configures a slave tester to prepare it to receive traffic, sends traffic, then queries the slave for results concerning the upstream link. Downstream - If you are testing Downstream, the slave generates traffic (as configured on the master tester), and then transmits the traffic to the master. Results for the downstream link are then displayed on the master tester.
66
67
4 Specify the Ethernet and VLAN or Q-in-Q settings (see Specifying Ethernet settings on page 25 and Specifying VLAN or Q-in-Q settings on page 27). If you are running an asymmetrical test, the frame type and tag settings must match on the near end and far end testers. 5 If you are running a L3 RFC 2544 test, specify the IP settings (see Specifying IP settings on page 46). 6 Do one of the following: If you are running an L2 RFC 2544 test, select the Frame Sizes option on the Configuration menu, and then select the size for the frames transmitted during testing. If you specify jumbo frames, specify the frame size in bytes. If you are running an L3 RFC 2544 test, select the Packet Sizes or Frame Sizes option on the Configuration menu, and then select the size for the packets or frames transmitted during testing. If you specify jumbo frames, specify the frame size in bytes. 7 On the Configuration menu, select Test Setup, and then select Test Selection. A menu of each of the available tests appears. If you want to run a particular test during this test session, select Yes; otherwise, select No. 8 Press Cancel to return to the Test Setup menu. For each test you selected in step 7, specify the required settings:
Test/Parameter Throughput Settings Specify: Bandwidth Acc %. Specify the bandwidth accuracy as a percentage of the line rate. BW Loss Tol %. Specify the frame loss tolerance as a ratio of lost frames to total frames transmitted. If you specify anything exceeding 0.00%, the test will not comply with the RFC 2544 standard. Trial Duration (sec). Specify the duration of each trial in seconds. Show Pass/Fail. Specify whether the tester should indicate whether the test passed or failed in the RFC 2544 log. Pass Threshold %. Specify the minimum bandwidth for the circuit as a percentage of the line rate. NOTE: If you are transmitting jumbo frames, allow at least ten seconds after starting the test to reach the bandwidth specified. Specify: Number of Trials. Specify the number of trials for the test. Trial Duration (sec). Specify the duration for each trial in seconds. Show P/F Status. Specify whether the tester should indicate whether the test passed or failed in the RFC 2544 log. Pass Threshold (ms). Specify the maximum average delay measurement that the test will find acceptable in milliseconds.
Latency (RTD)
68
Settings Specify: Number of Trials. Specify the number of trials for the test. Duration (sec). Specify the duration for each trial in seconds. Show Pass/Fail. Specify whether the tester should indicate whether the test passed or failed in the RFC 2544 log. Max Jitter (ms). Specify the maximum jitter measurement that the test will find acceptable in milliseconds. Specify: Bandwidth Gran. Specify the bandwidth granularity ranging from 1 to 10. Duration (sec). Specify the trial duration in seconds. Specify: Frame Granularity. Specify the frame granularity ranging from 1 to 1000. Number of Trials. Specify the number of times the tester will transmit back-to-back frames during the course of the test. Trial Duration (sec). Specify the duration for the test in seconds. Specify one of the following: Upstream, to run the script for the upstream link. Downstream, to run the script for the downstream link. Enter the source IP address for the traffic. Enter the subnet mask address for the traffic. Enter the default gateway for the traffic. Enter the default server address for the traffic. Specify the maximum bandwidth the tester will transmit during the course of running each of the tests you selected and configured. NOTE: The RFC 2544 test always transmits a constant load of traffic.
Frame Loss
Back-To-Back
Source Addr Subnet Mask Default Gateway Remote Srv Addr Max Bandwidth %
9 If you would like to include the customer name, technicians name, and the location of the test in the RFC 2544 log, on the Configuration menu, select User Info, then specify the information.
69
10 To start the test, press the #Start key. If you are running the symmetrical RFC 2544 Test, the Master tester loops up the Slave tester at the far end, and then starts the test. If you are running the asymmetrical RFC 2544 Test, and you indicated that you are testing Upstream, the Master tester configures the Slave tester to prepare it to receive traffic, sends traffic, and then queries the slave for results. If you are running the asymmetrical RFC 2544 Test, and you indicated that you are testing Downstream, the Master tester configures the Slave tester to transmit traffic, the slave sends traffic, and results for the downstream link are available on the master. The RFC 2544 log appears automatically (see Viewing the RFC 2544 log on page 70). After the RFC 2544 Test is complete, the tester creates a text file with an RFC2544 prefix. For information on downloading text files to Excel, see the instructions provided with the Download Manager utility.
70
Chapter 7
Managing Files
7
This chapter provides task-based instructions for managing stored configurations and results on the SmartClass Ethernet Tester. Topics discussed in this chapter include the following: About configuration and result files on page 72 Saving configurations on page 72 Viewing saved configurations on page 72 Restoring saved configurations on page 73 Saving results on page 73 Viewing saved results on page 73 Deleting saved configurations or results on page 74
71
Saving configurations
After you configure a test, you can save the configuration. To save a test configuration 1 If you havent already done so, launch your test application (see Launching an Ethernet test application on page 22 or Launching an IP test application on page 42), initialize the Ethernet link (see Initializing the link on page 22), and then configure the test (see Specifying L2 test application settings on page 24 or Specifying L3 test application settings on page 43). 2 On the Configuration menu, select Save/Restore-View. The Save/Restore-View menu appears. 3 Select Save Config. A screen appears prompting you for a filename for the configuration file. 4 Enter a filename, and then press OK. The configuration file is saved with a suffix that indicates the type of application the configuration is used for. For example, if you save a configuration that will be used to run an optical layer 3 streams application, the following suffix is automatically appended to your filename: O_L3STR
72
4 Use the up and down arrow keys to scroll through the settings. When you are finished, press Cancel to return to the previous screen. The saved configurations were displayed.
Saving results
After running a test, you can save the results, and then view them, print them, or import them into Excel at a later time. To save test results 1 After your test is finished, display the Results menu, and then select Save Results. A screen appears prompting you for a filename for the results file. 2 Enter a filename, and then press OK. The result file is saved. The test results are stored. For more information on downloading the results to Excel, see the instructions provided with the Download Manager utility.
73
3 Use the down arrow to scroll to and select the file you want to view, and then press OK. The View Results screen appears, listing the saved test results, and grouping them by category. Figure 14 illustrates the View Results screen for saved Electrical L3 Traffic Test results.
74
Chapter 8
8
This chapter describes the test results that are gathered when running a test. Topics in this chapter include the following: LEDs on page 76 Viewing test results on page 76 Freezing test results on page 77 Summary results on page 77 Link Status results on page 78 IP Config Status on page 81 Link Stats results on page 81 Link Counts results on page 83 Error Stats results on page 85 Stream test results on page 86 L2 BERT Stats results on page 87 L2 Pattern Stats on page 87 Ping Stats results on page 88 TraceRoute Log results on page 88 Cable Diagnostics results on page 88 Optical Signal results on page 90
75
LEDs
These status LEDs report the status of the tester. The function of each LED is described in Table 6
Table 6
LED Sync
Status LEDs
Function Indicates the status of the link. Solid green indicates that the link is active. If the Sync LED is not illuminated, a link is not established. Indicates the status of frame or packet detection. Green indicates frames or packets are being detected in the traffic stream. If the Frame LED is not illuminated, frames are not detected. Red indicates errors have been detected. A multi-color LED that indicates the battery status.
Frame
Error Battery
Solid green indicates that an external source is powering the tester. When the LED changes to a solid red, indicates that the battery is losing its charge, and has enough power to operate for an additional ten minutes. If your tester is powered using the AC adapter, on occasion, a solid red LED may indicate that the adapter has detected a fault condition. For details on correcting a fault condition, see Resolving problems on page 96. Solid amber indicates the battery is charging. No color indicates that a battery is powering the tester.
76
4 Select a result category. Test results appear for the category you selected. After the test is complete and all results have accumulated, the status bar at the bottom of the results display blinks and indicates that the results are complete. If you want to clear existing result values and then accumulate new values use the Restart action. You can also save the results, and then view, print, or export the results at a later time. For details, see Chapter 7 Managing Files.
Summary results
The Summary category automatically indicates whether errors were detected in the traffic stream, or that all results are OK. Key informational results are also provided. Table 7 describes each of the results that may appear in the Summary category.
Table 7
Result Errors
Link Active
77
Table 7
Result Status
Sync
Table 8
Result
1000Base-T FDX 1000Base-T HDX 100Base-TX FDX 100Base-TX HDX 10Base-T FDX 10Base-T HDX Duplex Flow Control Link Adv Status
78
Table 8
Result
Remote Fault Remote Loop Status Remote Unit ID Speed (Mbps) Src MAC Addr Stream n Dest MAC (L2 Streams Test only)
Table 9 describes the results that appear when initializing a link for 1G Ethernet optical testing.
Table 9
Result
79
Table 9
Result
Pause Capable
Remote Fault Remote Loop Status Remote Unit ID Src IP Addr Src MAC Addr Stream n Dest MAC (L2 Streams Test only)
Source IP Addr IP Gateway IP Subnet Mask Dest IP Addr Dest MAC Addr
80
IP Config Status
The IP Config Status category lists results associated with the assignment of static IP addresses, or the assignment of IP addresses by a DHCP server. Results in this category accumulate after you transmit traffic over the link. If you are running a L3 Streams test, results are provided for each enabled stream. Table 11 describes the results.
81
82
Util %, Cur
Util %, Max
Util %, Min
VLAN ID
1024-1518/1526
83
All Received Frames All Received Packets Broadcast Frames Multicast Frames Pause Frames
Q-in-Q Frames Received Frames Received Packets Rx Acterna Frames Rx Frame Bytes
Rx MPLS Frames Span Tree Frames Transmitted Frames Transmitted Packets Tx Acterna Frames Tx Frame Bytes
84
Lost Frames
OoS Frames
85
Stream results
The Stream category lists statistics for specific streams such as the bandwidth utilized by the stream and a count of received Acterna frames. Table 15 describes the results that appear in the Stream category.
Rx Acterna Frames Rx Mbps, Cur L1 Rx Mbps, Cur L2 Rx Dest MAC Rx Source MAC Util %, Avg
Util %, Cur
86
Util %, Min
Bit Errors
Error-Free Sec
Error-Free Sec %
L2 Pattern Stats
When running a L2 Pattern test, a count of the total number of frames received, and the total number of frames transmitted since the test started is provided in the L2 Pattern Stats category.
87
Requests Rx
Requests Tx
After running the electrical Ethernet Cable test, the Link Status category indicates one of the following: An active 10M or 100M link is established. If a 10M or 100M link is established, the MDI/MDIX status (see MDI or MDIX Pair Status result on page 89) is reported.
88
An active 1000M link is established. If a 1000M link is established, the pair status, polarity, and pair skew for each MDI pair is reported in the Cable Diagnostics category. See 1000M Pair Swap results on page 89, Polarity result on page 90 and Pair Skew result on page 90. The link is inactive. If the link is inactive, the Ethernet Tester indicates the type of fault and the faults relative distance from the tester in the Cable Diagnostics category (see Fault results on page 90).
The MDI/MDIX Status result indicates the resolved wiring (MDI, or MDIX) of the near end Ethernet Testers RJ-45 jack. For example, if the far end can not auto-configure its interface, (in other words, the wiring is fixed), this result can help you determine whether a straight through or crossover cable is being used or the MDI/MDIX wiring of the far end port. You must know the fixed MDI/MDIX status of the far end port to determine the type of cable using the near end MDI/MDIX Status result. For example, if you know that the far end port is fixed at MDI, and the near end port detects MDIX, then you can conclude that a straight through cable is used. You must know the cable type used to determine the MDI/MDIX status of the far end port using the near end MDI/MDIX Status result. For example, if you know you are using a straight through cable, and the near end port detects MDIX, you can conclude that the wiring at the far end port is MDI. Table 18 illustrates each of the possible resolutions.
The Pair Swap results for 1000M links provide the current pair assignments for the link. MDI pairs for 1000M links are assigned during the process of autonegotiation; therefore, if for any reason the link becomes inactive, and then the link is re-established, the pair assignments could potentially change. For example, the first time you establish a link after auto-negotiation, the following pairs could be assigned:
If the link goes down (becomes inactive), and then is re-established, the following pairs could be assigned:
89
Polarity result
The Polarity result indicates the polarity of each MDI pair on active 1000M links, indicating how each pair is physically wired to the Ethernet Tester port. Normal (+) indicates a normal polarity for the pair. Inverted (-) indicates an inverted polarity for the pair.
The Pair Skew result is a measurement of timing differences between the MDI pairs on active 1000M links. Timing differences may occur for a variety of reasons. For example, if different insulating materials are used on the pairs, a variance in the signal velocity (skew) may occur. If the skew is significant, transmission of the signal may be impaired to such a degree that the received signal can not be synchronized. Pair skew is reported in +/- 8ns increments.
Fault results
If a link is inactive, and a fault is detected, the Ethernet Tester indicates the type of fault detected (Open, Short, or Unknown) and the faults relative distance from the tester within +/- 1 meter. If you do not connect the cable to a far end device (completing the circuit), you can also use the Open detection feature to measure the length of a cable. Fault types are defined as follows: OpenIndicates there is a cut on the pair (or that the cable is not connected to a device at the far end of the circuit), and that the tester has detected an impedance exceeding 333 ohms. The distance from the near end tester to the end of the cable (or the cut) is also provided. ShortIndicates a positive and negative line on the same pair are touching, and that the tester has detected an impedance less than 33 ohms. UnknownIndicates the tester has detected impedance outside of the ranges stated for Open and Short faults, or that the cable is properly terminated into another Ethernet port. Unknown does not necessarily indicate that a fault was detected. NOTE: If the far end of the cable is connected to a powered down IP phone, and the phone is an older model, there is a filter that connects between pairs 1-2 and 3-6 in the phone. Depending on the characteristics of the filter, your tester may report a fault for pairs 1-2 and 3-6.
90
Chapter 9
9
This chapter describes how to maintain the Ethernet Testers batteries. Topics discussed in this chapter include the following: Prolonging battery life on page 92 Recharging the batteries on page 92 Replacing the batteries on page 93 WARNING: EXPLOSION HAZARD Only charge nickel metal hydride (NiMH) batteries. Do not charge alkaline batteries. Charging any other type of rechargeable or non-rechargeable (disposable) batteries may cause them to leak, rupture, or explode, causing injuries.
91
92
NOTE: If the AC adapter is connected to the tester and to an AC power supply, and the Battery LED is red, the charger has detected a fault condition, or the battery has less than ten minutes of power remaining. For details on correcting this condition, see Resolving problems on page 96. WARNING: ELECTRICAL SHOCK Electrical shock may result in serious injury or death. Be sure the AC Adapter is connected to the correct voltage mains. Do not use outdoors or in wet locations. Use only the AC Adapter supplied with the test set. 3 Let the SmartClass charge for 2 to 4 hours depending on the voltage level. The Batt LED is amber when the tester is charging the battery. Charging the batteries is complete when the Batt LED is green.
Battery compartment
93
3 Using a screwdriver, remove the screw from the battery compartment door, and then press down and push the panel toward the bottom end. 4 Replace the batteries, with polarities oriented as shown in Figure 16.
94
Chapter 10
Troubleshooting
10
This chapter describes how to identify and correct problems related to the SmartClass Ethernet Tester. Topics discussed in this chapter include the following: Getting Technical Assistance on page 96 Resolving problems on page 96
95
Resolving problems
If you are having trouble with the Ethernet Tester, the following sections describe common problems and solutions. You should verify whether your problem is listed here before contacting technical assistance. The following section addresses questions that may be asked about completing tests with the SmartClass. There are two sections included: General Ethernet tests
General testing
The following section addresses questions about testing in general using SmartClass Testers. Issue Batteries are fully charged, and the external power adapter is attached, but the Batt LED on the tester is red. Resolution The charger has detected a fault condition. Turn the tester OFF, and then disconnect the external power adapter. Verify that the batteries installed in your tester are NiMH batteries, and that they are installed in the proper orientation (see Figure 16 on page 94). Always use JDSU recommended batteries in your tester. Issue Batteries are not detected by the tester. Resolution The battery charge is depleted to such a degree that the tester can no longer detect or charge them. Replace the batteries (see Recharging the batteries on page 92.
The following section addresses questions about Ethernet and IP testing. Issue Link is not active.
96
Resolution Verify that the tester on the far end is connected to the circuit. Verify that the tester and its link partner are configured for the same rate of traffic. Verify that the tester and its link partner both have auto-negotiation turned ON, and share at least one common capability, or that both have auto-negotiation turned OFF. Issue Hard loopback at the far end is failing. Resolution If you are testing on a switched Ethernet network, you must use two testers as end stations on a circuit. If you are performing a layer 3 IP loopback test on an Ethernet network that doesnt support VLAN or Q-in-Q tagging, and you transmit tagged traffic, the loopback will fail. Reconfigure the tester to transmit untagged traffic. NOTE: If you are testing on an unswitched Ethernet network, you can use a hard loopback at the far end of the circuit.
97
98
Appendix A
Specifications
A
This appendix contains specifications for the Ethernet Tester. Topics discussed in this appendix include the following: Connector specifications on page 100 Environmental specifications on page 100 Power specifications on page 100 Warranty information on page 101
99
Connector specifications
Table 21 provides the connector specifications.
RJ-45 USB DC
Environmental specifications
Table 22 provides the environmental specifications without batteries.
Humidity
a. Without Batteries
Power specifications
Although battery life varies, depending on the type of battery and the type of test, Table 23 provides specifications for the battery life of the recommended Energizer or Sanyo 2500 mAh NiMH rechargeable batteries, and the specifications for the AC adapter.
100
Warranty information
The warranties described herein shall apply to all commercially available JDSU (formerly Acterna) products. Any additional or different warranties shall apply only if agreed to by JDSU in writing. These warranties are not transferable without the express written consent of JDSU. Hardware Warranty JDSU warrants that Hardware Product sold to customer shall, under normal use and service, be free from defects in materials and workmanship. Information regarding the specific warranty period for this product can be obtained by contacting your local JDSU Customer Service Representative, or at our web site www.jdsu.com. The warranty period shall begin upon shipment to Customer. Hereafter these periods of time shall be collectively referred to as the Initial Warranty Period. JDSUs obligation and customers sole remedy under this Hardware Warranty is limited to the repair or replacement, at JDSUs option, of the defective product. JDSU shall have no obligation to remedy any such defect if it can be shown: (a) that the Product was altered, repaired, or reworked by any party other than JDSU without JDSUs written consent; (b) that such defects were the result of customers improper storage, mishandling, abuse, or misuse of Product; (c) that such defects were the result of customers use of Product in conjunction with equipment electronically or mechanically incompatible or of an inferior quality; or (d) that the defect was the result of damage by fire, explosion, power failure, or any act of nature. JDSU performed repairs shall be warranted from defective material and workmanship for a period of ninety (90) days, or until the end of the Initial Warranty Period, whichever is longer. Risk of loss or damage to Product returned to JDSU for repair or replacement shall be borne by customer until delivery to JDSU. Upon delivery of such product, JDSU shall assume the risk of loss or damage until that time that the product being repaired or replaced is returned and delivered to customer. Customer shall pay all transportation costs for equipment or software shipped to JDSU for repair or replacement. JDSU shall pay all transportation costs associated with returning repaired or replaced product to customer. Software Warranty JDSU warrants that Software Products licensed to Customer shall, under normal use and service, and for a period of ninety (90) days from the date of shipment of the Software to Licensee (the Warranty Period), perform in all material respects in accordance with the published specifications for such Software as established by JDSU. However, JDSU does not warrant that the Software will operate uninterrupted or error free, operate in the combination with other software, meet Customers requirements, or that its use will be uninterrupted. JDSUs obligation and Customers sole and exclusive remedy under this Software Warranty is limited to, at JDSUs option, either (i) correcting the material errors reported to JDSU in writing by Customer during the Warranty Period and which JDSU is able to reproduce, (ii) replacing such defective Software, provided that JDSU received written notice of such defect within the Warranty Period, or (iii) provided that JDSU received written notice of such defect within the Warranty Period, terminating the License and, upon return to JDSU of the Software, Documentation and all other materials provided by JDSU under the applicable License, providing Customer with a refund of all charges paid with respect thereto. JDSU shall have no warranty obligations hereunder if (a) the Software is altered or modified or is merged with other software by Customer or any third
101
party or (b) all or any part of the Software is installed on any computer equipment other than the Designated Server or used with any operating system for which the Software is not designed. WARRANTY DISCLAIMER FOR HARDWARE, AND/OR SOFTWARE FURNISHED BY JDSU, THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTEES AND CONDITIONS, EXPRESS OR IMPLIED. JDSU SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, ON ANY HARDWARE, SOFTWARE, DOCUMENTATION OR SERVICES INCLUDING BUT NOT LIMITED TO WARRANTIES RELATING TO QUALITY, PERFORMANCE, NONINFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AS WELL AS THOSE ARISING FROM ANY COURSE OF DEALING, USAGE OR TRADE PRACTICE. UNDER NO CIRCUMSTANCES WILL JDSU BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES RELATED TO BREACH OF THIS WARRANTY.
102
Communications Test and Measurement Regional Sales North America Toll Free: 1 800 638 2049 Tel: +1 240 404 2999 Fax:+1 240 404 2195 Latin America Tel: +55 11 5503 3800 Fax:+55 11 5505 1598 Asia Pacific Tel: +852 2892 0990 Fax:+852 2892 0770 EMEA Tel: +49 7121 86 2222 Fax:+49 7121 86 1222 www.jdsu.com