SMS BASED VOTING MACHINE Project Report
SMS BASED VOTING MACHINE Project Report
CHAPTER 1 INTRODUCTION
1.1 Introduction to SMS Based Voting Machine
India is worlds largest democracy. Fundamental right to vote or simply voting in elections forms the basis of Indian democracy. In India all earlier elections a voter used to cast his vote by using ballot paper. This is a long time-consuming process and very much prone to errors. This situation continued till election scene was completely changed by electronic voting machine. No more ballot paper, ballot boxes, stamping, etc. All this condensed into a simple box called ballot unit of the electronic voting machine. Cell phone based voting machine is capable of saving considerable printing stationery and transport of large volumes of electoral material. It is easy to transport, store, and maintain. It completely rules out the chance of invalid votes. It reduces of polling time, resulting in fewer problems in electoral preparations, law and order, candidates expenditure, etc. and easy and accurate counting without any mischief at the counting centre. The aim of our project is to design & develop a mobile based voting machine. This project focuses onto implement GSM (Global System for Mobile Communication) based Voting System. This system is implemented using an embedded microcontroller. The embedded microcontroller used here is AT89S52microcontroller. Actually, the aim of the project is to implement an Automatic Voting system. GSM Based voting machine is fully controlled system. There is no chance of any mistake. Primarily, the system functions with the help of different technologies like the traditional cellular network such as Global System for Mobile Communications (GSM) and other radio frequency medium. Today GSM fitted Banks, cars; ambulances, fleets and police vehicles are common sights. The functional units of our projects are GSM MODEM, LCD display, PC data base and AT89S52.
1.2
The aim of our project is to design & develop a mobile based voting machine. In this project user can dial the specific number from any land line or mobile phone to cast his vote. Once the user is connected to the voting machine he can enter his password & choice of vote. If
1
SMS BASED VOTING MACHINE he has entered a valid choice & password his vote will be caste with two short duration beeps. For invalid password/choice long beep will be generated. User is allotted 15 seconds to enter his password & choice. A reset button is provided for resetting the system. A total key is provided to display the result. We have also used non-volatile memory for storing all data. EEPROM will preserve all information in case of power failure.
1.3
At present Electronic Voting Machines ("EVM") are being used in Indian General and State Elections to implement electronic voting in part from 1999 elections and in total since 2004 elections. The EVMs reduce the time in both casting a vote and declaring the results compared to the old paper ballot system. However, EVMs have been under a cloud of suspicion over their alleged tamping arability and security problems during elections (especially after the 2009 general elections). An EVM consists of two units: Control Unit Balloting Unit
The Control Unit is with the Polling Officer and the Balloting Unit is placed inside the voting compartment
Fig 1.1: Typical Electronic Voting Machine But EVM is very complicated and there is lot of wasting of time and money so SMS voting machine can be a safer mode of casting vote with respect to Electronic Voting Machines (EVM).
1.4
The current technology used in the project is SMS (Short Message Service) service based on GSM (Global System for Mobile).GSM (Global System for Mobile communications) is an open, digital cellular technology used for transmitting mobile voice and data services.
2
SMS BASED VOTING MACHINE GSM supports voice calls and data transfer speeds of up to 9.6 kbps, together with the transmission of SMS (Short Message Service). GSM operates in the 900MHz and 1.8GHz bands in Europe and the 1.9GHz and 850MHz bands in the US. The use of harmonized spectrum across most of the globe, combined with GSMs international roaming capability, allows travellers to access the same mobile services at home and abroad. GSM enables individuals to be reached via the same mobile number in up to 219 countries. Terrestrial GSM networks now cover more than 90% of the worlds population. GSM satellite roaming has also extended service access to areas where terrestrial coverage is not available.
EEPROM
LCD
MOBILE
SMS BASED VOTING MACHINE should be inserted into one of the PC Card slots of a laptop computer. Like a GSM mobile phone, a GSM modem requires a SIM card from a wireless carrier in order to operate computers use AT commands to control modems. These extended AT commands are defined in the GSM standards. With the extended AT commands Reading, writing, deleting and Sending SMS messages are monitored.
2.1.3 Mobile
Here mobile is the user mobile whos SIM card number has been priory registered in voting machine. Through mobile user will have to cast his\her vote in specific format using Short Message Service (SMS).
2.1.4 PC Database
Computer (PC) is used as common interface between microcontroller and GSM module. Software tool visual basic 6.0 is used to control, store and secondary display of votes. In software part two forms are made one for administration access and another for voting status display where all options are available for storage display and control.
the
same
circuit,
if
SMS BASED VOTING MACHINE necessary.78xx ICs have three terminals and are most commonly found in the TO220 form factor, although smaller surface- mount and larger TO3 packages are also available from some manufacturers. These devices typically support an input voltage which can be anywhere from a couple of volts over the intended output voltage, up to a maximum of 35 or 40 volts, and can typically provide up to around 1 or 1.5 amps of current .
2.1.7 LCD
In this project 16*2 LCD is used. This LCD is interface with AT89S52 at port 2.It used to display voting result with candidates A, B, C, D.
Sr.no 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 12. 13. 14. 15. 16. 17. 18. 19.
Component Microcontroller LCD display LED Resistor Crystal oscillator Capacitor MAX 232 GSM module SIM card Copper clad Voltage regulator IC Berge strip Connecting wires ZIF Resistance array Computer setup DB-9 Connector Switch
Specification (AT89S52) 16*2 text 1K,10K (11.0592Mhz) (33pf,10mf(63V),) SIM300 Any 7805 Male Female(16 pin)
40 pin
Description
The AT89S52 is a low-power, high-performance CMOS 8-bit microcomputer with 8K bytes of Flash programmable and erasable read only memory (PEROM). The device is manufactured using Atmels high-density non-volatile memory technology and is compatible with the industry-standard 80C51 and 80C52 instruction set and pin out. The onchip Flash allows the program memory to be reprogrammed in-system or by a conventional non-volatile memory programmer. By combining a versatile 8-bit CPU with Flash on a monolithic chip, the Atmel AT89S52 is a powerful microcomputer which provides a highlyflexible and cost-effective solution to many embedded control applications.
10
Features of 8052:
Compatible with MCS-51 Products 8K Bytes of In-System Reprogrammable Flash Memory Endurance: 1,000 Write/Erase Cycles Fully Static Operation: 0 Hz to 24 MHz Three-level Program Memory Lock 256 x 8-bit Internal RAM 32 Programmable I/O Lines Three 16-bit Timer/Counters Eight Interrupt Sources Programmable Serial Channel Low-power Idle and Power-down Modes
PIN DESCRIPTION:
VCC Supply voltage. GND Ground. Port 0 Port 0 is an 8-bit open drain bi-directional I/O port. As an output port, each pin can sink eight TTL inputs. When 1s are written to port 0 pins, the pins can be used as high impedance inputs. Port 0 can also be configured to be the multiplexed low order address/data bus during accesses to external program and data memory. In this mode, P0 has internal pull-ups. Port 0 also receives the code bytes during Flash programming and outputs the code bytes during program verification. External pull-ups are required during program verification. Port 1 Port 1 is an 8-bit bi-directional I/O port with internal pull-ups. The Port 1 output buffers can sink/source four TTL inputs. When 1s are written to Port 1 pins, they are pulled high by the internal pull-ups and can be used as inputs. As inputs, Port 1 pins that are externally being pulled low will source current (IIL) because of the internal pull-ups. In addition, P1.0 and P1.1 can be configured to be the timer/counter 2 external count input (P1.0/T2) and the
11
SMS BASED VOTING MACHINE timer/counter 2 trigger input (P1.1/T2EX), respectively, as shown in the following table. Port 1 also receives the low-order address bytes during Flash programming and verification. Port 2 Port 2 is an 8-bit bi-directional I/O port with internal pull-ups. The Port 2 output buffers can sink/source four TTL inputs. When 1s are written to Port 2 pins, they are pulled high by the internal pull-ups and can be used as inputs. As inputs, Port 2 pins that are externally being pulled low will source current (IIL) because of the internal pull-ups. Port 2 emits the highorder address byte during fetches from external program memory and during accesses to external data memory that uses 16-bit addresses (MOVX @ DPTR). In this application, Port 2 uses strong internal pull-ups when emitting 1s. During accesses to external data memory that uses 8-bit addresses (MOVX @ RI), Port 2 emits the contents of the P2 Special Function Register. Port 2 also receives the high-order address bits and some control signals during Flash programming and verification. Port 3 Port 3 is an 8-bit bi-directional I/O port with internal pull-ups. The Port 3 output buffers can sink/source four TTL inputs. When 1s are written to Port 3 pins, they are pulled high by the internal pull-ups and can be used as inputs. As inputs, Port 3 pins that are externally being pulled low will source current (IIL) because of the pull-ups. Port 3 also serves the functions of various special features of the AT89S51, as shown in the following table. Port 3 also receives some control signals for Flash programming and verification. Table 3.2: Port 3 description Port Pins P 3.0 P 3.1 P 3.2 P 3.3 P 3.4 P 3.5 P 3.6 P 3.7 Alternate Function RXD(serial input port) TXD(serial output port) INT0 (external interrupt 0) INT1(external interrupt 1) T0(Timer 0 external input) T1(Timer 1external input) WR (external data memory write strobe) RD (external data memory read strobe)
12
SMS BASED VOTING MACHINE RST Reset input. A high on this pin for two machine cycles while the oscillator is running resets the device. ALE/PROG Address Latch Enable is an output pulse for latching the low byte of the address during accesses to external memory. This pin is also the program pulse input (PROG) during Flash programming. In normal operation, ALE is emitted at a constant rate of 1/6 the oscillator frequency and may be used for external timing or clocking purposes. Note, however, that one ALE pulse is skipped during each access to external data memory. If desired, ALE operation can be disabled by setting bit 0 of SFR location 8EH. With the bit set, ALE is active only during a MOVX or MOVC instruction. Otherwise, the pin is weakly pulled high. Setting the ALE-disable bit has no effect if the microcontroller is in external execution mode. PSEN Program Store Enable is the read strobe to external program memory. When the AT89S52 is executing code from external program memory, PSEN is activated twice each machine cycle, except that two PSEN activations are skipped during each access to external data memory. EA/VPP External Access Enable. EA must be strapped to GND in order to enable the device to fetch code from external program memory locations starting at 0000H up to FFFFH. Note, however, that if lock bit 1 is programmed, EA will be internally latched on reset EA should be strapped to VCC for internal program executions. This pin also receives the 12-volt programming enable voltage (VPP) during Flash programming when 12-volt programming is selected. XTAL1 Input to the inverting oscillator amplifier and input to the internal clock operating circuit. XTAL2 Output from the inverting oscillator amplifier.
13
Interrupts
The AT89S52 has a total of six interrupt vectors: two external interrupts (INT0 and INT1), three timer interrupts (Timers 0, 1, and 2), and the serial port interrupt. Each of these interrupt sources can be individually enabled or disabled by setting or clearing a bit in Special Function Register IE. IE also contains a global disable bit, EA, which disables all interrupts at once. In the AT89C51, bit position IE.6 and IE.5 are unimplemented. User software should not write 1s to these bit positions, since they may be used in future AT89 products. Timer 2 interrupt is generated by the logical OR of bits TF2 and EXF2 in register T2CON. Neither of these flags is cleared by hardware when the service routine is vectored to. In fact, the service routine may have to determine whether it was TF2 or EXF2 that generated the interrupt, and that bit will have to be cleared in software. The Timer 0 and Timer 1 flags, TF0 and TF1, are set at S5P2 of the cycle in which the timers overflow. The values are then polled by the circuitry in the next cycle. However, the Timer 2 flag, TF2, is set at S2P2 and is polled in the same cycle in which the timer overflows. Table 3.3: Interrupts (MSB) EA ET2 ES ET1 EX1 ET0 (LSB) EX0
Enable Bit = 1 enables the interrupt. Enable Bit = 0 disables the interrupt.
14
Fig 3.3: MAX 232 IC The MAX232 is an integrated circuit that converts signals from an RS-232 serial port to signals suitable for use in TTL compatible digital logic circuits. The MAX232 is a dual driver/receiver and typically converts the RX, TX, CTS and RTS signals. The drivers provide RS- 232 voltage level outputs (approx. 7.5 V) from a single +5V supply via onchip charge pumps and external capacitors. This makes it useful for implementing RS-232 in devices that otherwise do not need any voltages outside the 0V to + 5 V range, as power supply design does not need to be made more complicated just for driving the RS-232 in this case. The receivers reduce RS-232inputs (which may be as high as 25 V), to standard 5 V TTL levels. These receivers have atypical threshold of 1.3 V, and a typical hysteresis of 0.5 V. The later MAX232A is backwards compatible with the original MAX232 but may operate at higher baud rates and can use smaller external capacitors 0.1 F in place of the 1.0 F capacitors used with the original device. The newer MAX3232 is also backwards compatible, but operates at a broader voltage range, from 3 to 5.5V. The later MAX232A is backwards compatible with the original MAX232 but may operate at higher baud rates and can use smaller external capacitors 0.1 F in place of the 1.0 F capacitors used with the original device. The newer MAX3232 is also backwards compatible, but operates at a broader voltage range, from 3 to 5.5 V. Pin to pin compatible: ICL232, ST232, ADM232, HIN232 (much cheaper alternatives).
15
3.2.3 GS M MODULE
Fig 3.4: GSM Module A GS M modem is a wireless modem that works with a GSM wireless network. A wireless modem behaves like a dial- up modem. The main difference between them is that a dial- up modem sends and receives data through a fixed telephone line while a wireless modem Sends and receives data through radio waves. A GSM modem can be an external device or a PC Card PCMCIA Card. Typically, an external GSM modem is connected to a computer through a serial cable or a USB cable. A GSM modem in the form of a PC Card / PCMCIA Card is designed for use with a laptop computer. It should be inserted into one of the PC Card /PCMCIA Card slots of a laptop computer. Like a GSM mobile phone, a GSM modem requires a SIM card from a wireless carrier in order to operate. As mentioned below of this SMS tutorial l computers use AT commands to control modems. Both GSM modems and dial-up modems support a common set of standard AT commands. You can use a GSM modem just like a dial- up modem. In addition to the standard AT commands; GSM modems support an extended set of AT commands. These extended AT commands are defined in the GSM standards. With the extended AT commands, you can do things like: 1. Reading, writing and deleting SMS messages. 2. Sending S MS messages. 3. Monitoring the signal strength. 4. Monitoring the charging status and charge level of the battery. 5. Reading, writing and searching phone book entries.
16
The number of SMS messages that can be processed by a GSM modem per minute is very low -- only about six to ten SMS messages per minute. 3.2.3.1 AT Commands AT commands are instructions used to control a modem. AT is the abbreviation of Attention. Every command l i n e starts with AT or at". Thats why m odem
commands are called AT commands. Many of the commands that are used to control wired dial- up modems, such as ATD (Dial), ATA (Answer), ATH (Hook control) and ATO (Return to online data state), are also supported by GSM/GP RS modems and mobile phones. Besides this common AT command set, GS M/GPRS modems and mobile phones support an AT command set that is specific to the GSM technology, which includes SMS-related commands like AT+CMGS (Send SMS message), AT+CMSS (Send SMS message from storage), AT+CMGL (List SMS messages) and AT+CMGR (Read SMS messages). Note that the starting "AT" is the prefix that informs the modem about the start of a command line. It is not part of the AT command name. For example, D is the actual AT command name in ATD and +CMGS is the actual AT command name in AT+CMGS. However, some books and web sites use them interchangeably as the name of an AT command. Here are some of the tasks that can be done using AT commands with a GS M/GPRS modem or mobile phone: 1. Get basic information about the mobile phone or GS M/GPRS modem. For example, name of manufacturer (AT+CGMI), model number (AT+CGMM), IMEI number (International Mobile Equipment Identity) (AT+CGSN) and software version (AT+CGMR). 2. Get basic information about the and IMSI number subscriber. For example Subscriber MSISDN Identity)
(AT+CNUM) (AT+CIMI).
(International Mobile
3. Get the current status of the mobile phone or GSM/GP RS modem. For example, mobile phone activity status
17
(AT+CPAS),
registration status (AT+CREG), radio signal strength (AT+CSQ), battery charge level
SMS BASED VOTING MACHINE and battery charging status (AT+C BC). 4. Establish a data connection or voice connection to a remote modem (ATD, ATA, etc.). 5. Send and receive fax (ATD, ATA, AT+F*). 6. Send (AT+CMGS, AT+CMSS), read (AT+CMGR, AT+CMGL), write
(AT+CMGW) or delete (AT+CMGD) SMS messages and obtain notifications of newly received SMS messages (AT+CNMI). 7. Read (AT+CP BR), write (AT+CPBW) or search (AT+CPBF) phonebook entries. 8. Perform security-related t a s k s , s u c h as opening or c l os i n g facility l o c k s (AT+CLCK), checking whether a facility is locked (AT+CLCK) and changing passwords (AT+CPWD). (Facility lock examples: SIM lock [a password must be given to the SIM card every time the mobile phone is switched on] and P H-SIM lock [a certain SIM card is associated with the mobile phone. To use other S IM cards with the mobile phone, a password must be entered.]) 9. Control the presentation of result codes / error messages of AT commands. For example, you can control whether to enable certain error messages (AT+CMEE) and whether error messages should be displayed in numeric format or verbose format (AT+CMEE=1 or AT+CMEE=2). 10. Get or change the configurations of the mobile phone or GSM/GPRS modem. For example, change the GSM network (AT+COPS), bearer service type (AT+CBS T), radio link protocol parameters (AT+CRLP), SMS center address (AT+CSCA) and storage of SMS messages (AT+CPMS). 11. Save and restore configurations of the mobile phone or GSM/GP RS modem. For example, save (AT+CSAS) and restore (AT+CRES) settings related to SMS messaging such as the SMS center address. Note that mobile phone manufacturers usually do not implement all AT commands, command parameters and parameter values in their mobile phones. Also, the behaviour of the implemented AT commands may be different from that defined in the standard. In general, GSM/GPRS m o d e m s designed f o r wireless applications have better support of AT commands than ordinary mobile phones. In addition, some AT commands require the support of mobile network operators. For example, SMS over GP RS can be enabled on some GP RS mobile phones and GPRS
18
SMS BASED VOTING MACHINE modems with the +CGSMS command (command name in text: Select Service for MO SMS Messages). But if the mobile network operator does not support the transmission of SMS over GP RS, you cannot use this features .There are two types of AT commands: basic commands and extended commands. Basic commands are AT commands that do not start with "+". For example, D (Dial), A (Answer), H (Hook control) and O (Return to online data state) are basic commands. Extended commands are AT commands that start with "+". All GSM AT commands are extended commands. For example, +CMGS (Send SMS message), +CMSS (Send SMS message from storage), +CMGL (List SMS messages) and +CMGR (Read SMS messages) are extended commands. 3.2.3.2 General Syntax of Extended AT Commands The general syntax of extended AT commands is straightforward. The syntax rules are provided below. The syntax of basic AT commands is slightly different. We will not cover the syntax of basic AT commands in this SMS tutorial since all SMS messaging commands are extended AT commands. Syntax rule 1. All command lines must start with "AT" and end with a carriage return character. (We will use <C R> to represent a carriage return character in this SMS tutorial.) In a terminal program like HyperTerminal of Microsoft Windows, you can press the Enter key on the keyboard to output a carriage return character. Example: To list all unread inbound SMS messages stored in the message storage area, type "AT", then the extended AT command "+CMGL", and finally a carriage return character, like this: AT+CMGL<CR> Syntax rule 2. A command line can contain more than one AT command. Only the first AT command should be prefixed with "AT". AT commands in the same command- line string should be separated with semicolons. Example: To list all unread inbound SMS messages stored in the message storage area and obtain the manufacturer name of the mobile device, type "AT", then the extended AT command "+CMGL", followed by a semicolon and the next extended AT
An error will occur if both AT commands are prefixed with "AT", like this: AT+CMGL; AT+C GMI<CR> Syntax rule 3. A string is enclosed between double quotes. Example: To read all SMS messages from message storage in SMS text mode (at this time you do not need to know what SMS text mode is. More information will be provided later in this SMS tutorial), you need to assign the string "ALL" to the extended AT command +CMGL, like this: AT+CMGL="ALL"<CR> Syntax rule 4. Information responses and result codes (including both final result codes and unsolicited result codes) always start and end with a carriage return character and a linefeed character. Example: After sending the command line "AT+CGMI<CR>to the mobile device, the mobile device should return a response similar to this: The first line is the information response of the AT command +CGMI and the second line is the final result code. <C R> and <LF> represent a carriage return character and a line feed character respectively. The final results c o d e "OK marks the end of the response. It indicates no more data will be sent from the mobile device to the computer / PC. When a terminal program such as HyperTerminal of Microsoft Windows sees a carriage return character, it moves the cursor to the beginning of the current line. When it sees a linefeed character, it moves the cursor to the same position on the next line. Hence, the command line "AT+CGMI<CR> " that you entered and the
corresponding response will be displayed like this in a terminal program such as HyperTerminal of Microsoft Windows: AT+C GMI Nokia OK 3.2.3.3 Information Response and Final Result Code Don't forget the meanings of information response and final result code stated above, since you will see these two terms frequently as you go through this SMS tutorial. 20 Dept. of E&C, PCE
SMS BASED VOTING MACHINE Result codes of AT commands: Result codes are messages sent from the GSM/GP RS modem or mobile phone to provide you information about the execution of an AT command and the occurrence of an event. Two types of result codes are useful to you when dealing with AT commands for SMS messaging: Final result codes Unsolicited result codes
Final Result Codes of AT Commands: A final result code marks the end of an AT command response. It is an indication that the GSM/GP RS modem or mobile phone has finished the execution of a command line. Two frequently used final result codes are OK and ERRO R. Only one final result code will be returned for each command line. Thus, you will not see both OK and ERROR in the response of a command line.
The OK Final Result Code: The OK final result code indicates that a command line has been executed successfully by the GSM/GP RS modem or mobile phone. It always starts and ends with a carriage return character and a linefeed character. Here is an example for illustration. Let's say you send the command line "AT+CMGL; +CGMI<C R>to your GSM/GPRS modem. The AT c o m m a n d "+CMGL" is
used to list SMS messages stored in the message storage area and the AT command +CGMI" is used to get the manufacturer name of the GS M/GPRS modem. If everything works properly without any errors, the command line, together with the response returned, should be something similar to this: AT+CMGL; +CGMI<CR> <CR><LF> +CMGL: 1,"REC UNREAD","+85291234567", 06/11/11, 00:30:29+32"<C R><LF>Welcome to our SMS tutorial. <CR><LF> <CR><LF> Nokia
<CR><LF><CR><LF>OK<CR><LF> As mentioned earlier, when a terminal program such as HyperTerminal of Microsoft Windows sees a carriage return character, it moves the cursor to the beginning of the current line. When it sees a linefeed character, it moves the cursor to the same position on the next line. Hence, the command line you entered, together with the response returned, will be displayed like this in a terminal program such as HyperTerminal of Microsoft Windows : AT+CMGL; +CGMI
21
SMS BASED VOTING MACHINE +CMGL: 1,"REC UNREAD","+7568501753", 06/11/11, 00:30:29+32" Welcome to our SMS tutoria l. Nokia OK 3.2.3.4 SMS Tutorial In general, there are two ways to send SMS messages from a computer / PC to a mobile phone: 1. Connect a mobile phone or GSM/GPRS modem to a computer / PC. Then use the
computer / PC and AT commands to instruct the mobile phone or GSM/GPRS modem to send SMS messages. 2. Connect the computer / PC to the SMS center (SMSC) or SMS gateway of a wireless carrier or SMS service provider. Then send SMS messages using a protocol / interface supported by the S MSC or SMS gateway. 3.2.3.5 The 1st Way: Sending S MS Messages from a Computer Using a Mobile P hone or GSM/GP RS Modem The SMS specification has defined a way for a computer to send SMS messages through a mobile phone or GS M/GPRS modem. A GSM/GP RS modem is a wireless modem that works with GS M/GPRS wireless networks. A wireless modem is similar to a dial-up modem. The main difference is that a wireless modem transmits data through a wireless network whereas a dial-up modem transmits data through a copper telephone line. Most mobile phones can be used as a wireless modem. However, some mobile phones have certain limitations comparing to GSM/GPRS modems. To send SMS messages, first place a valid SIM card from a wireless carrier into a mobile phone or GSM/GP RS modem, which is then connected to a computer. There are several ways to connect a mobile phone or GSM/GP RS modem to a computer. For example, they can be connected through a serial cable, a USB cable, a Bluetooth link or an infrared link. The actual way to use depends on the capability of the mobile phone or GSM/GP RS modem. For example, if a mobile phone does not support Bluetooth, it cannot connect to the computer through a Bluetooth link. After connecting a mobile phone or GSM/GP RS modem to a computer, you can
22
SMS BASED VOTING MACHINE control the mobile phone or GSM/GP RS modem by sending instructions to it. The instructions used for controlling the mobile phone or GS M/GPRS modem are called AT commands. (AT commands are also used to control dial- up modems for wired telephone system.) Dial- up modems, mobile phones and GSM/GP RS modems support a common set of standard AT commands. In addition to this common set of standard AT commands, mobile phones and GSM/GP RS modems support an extended set of AT commands. One use of the extended AT commands is to control the sending and receiving of SMS messages. The following table lists the AT commands that are related to the writing and sending of SMS messages: AT command +CMGS +CMSS +CMGW +CMGD +CMGC +CMMS Table 3.4: AT Command TX Meaning Send message Send message from storage Write message to memory Delete message Send command More messages to send
One way to send AT commands to a mobile phone or GSM/GP RS modem is to use a terminal program. A terminal program's function is like this: It sends the character you typed to the mobile phone or GSM/GP RS modem. It then displays the response it receives from the mobile phone or GSM/GPRS modem on the screen. The terminal program on Microsoft Windows is called HyperTerminal. Below shows a simple example that demonstrates how to use AT commands and the HyperTerminal program of
Microsoft Windows to send an SMS text message. The lines in bold type are the command lines that should be entered in HyperTerminal. The other lines are responses returned from the GSM / GP RS modem or mobile phone.
23
AT OK AT+CMGF=1 OK AT+CMGW="+7568501753"> A simple demo of SMS text messaging. +CMGW: OK AT+CMSS=1 +CMSS: OK To send SMS messages from an application, you have to write the source code for connecting to and sending AT commands to the mobile phone or GS M/GPRS modem, just like what a terminal program does. You can write the source code in C, C++, Java, Visual Basic, Delphi or other programming languages you like. However, writing your own code has a few disadvantages:
1.
You have to learn how to compose the bits and bytes of an SMS message. For example, to specify the character encoding (e.g. 7-bit encoding and 16-bit Unicode encoding) of an SMS message, you need to know which bits in the message header should be modified and what value should be assigned.
2.
Sending SMS messages with a mobile phone or GSM/GP RS modem has a drawback -- the SMS transmission speed is low. As your SMS messaging application becomes more popular, it has to handle a larger amount of SMS traffic and finally the mobile phone or GSM/GPRS modem will not be able to take the load. To obtain a high SMS transmission speed, a direct connection to an SMSC or S MS gateway of a wireless carrier or S MS service provider is needed. However, AT commands are not used for communicating with an SMS center or SMS gateway. This means you have to make a big change to your SMS messaging application in order to move from a wireless- modem- based solution to a SMSC-based solution.
In most cases, instead of writing your own code for interacting with the mobile phone or GSM/GPRS modem via AT commands, a better solution is to use a high- level SMS messaging API (Application programming interface) / S DK (Software
development kit) / library. The AP I / SDK / library encapsulates the low- level details. So, an SMS application developer does not need to know AT commands and the composition of S MS messages in the bit-level. Some SMS messaging APIs / S DKs / libraries support SMSC protocols in addition to AT commands. To move from a
24
SMS BASED VOTING MACHINE wireless- modem-based SMS solution to a SMSC-based SMS solution, usually you just need to modify a configuration file / property file or make a few changes to your SMS messaging application's source code. Another way to hide the low-level AT command layer is to place an SMS gateway between the SMS messaging application and the mobile phone or GS M/GPRS modem. (This has been described in the section "What is an SMS Gate way? earlier.) Simple protocols such as HTTP / HTTPS can then be used for sending S MS messages in the application. If an SMSC protocol (e.g. SMPP, CIMD, etc.) is used for communicating with the SMS gateway instead of HTTP / HTTPS, an SMS messaging API / S DK / library can be very helpful to you since it encapsulates the SMSC protocol's details. Usually a list of supported / unsupported mobile phones or wireless modems is provided on the web site of an SMS messaging API / SDK / library or an SMS gateway software package. Remember to check the list if you are going to use an SMS messaging API / SDK / library or an S MS gateway software package. 3.2.3.6 How to receive SMS messages using Computer/PC In general, there are three ways to receive SMS messages using your computer / PC: 1. Connect a mobile phone or GSM/GPRS modem to a computer / PC. Then use the computer / PC and AT commands to get the received SMS messages from the mobile phone or GSM/GP RS modem. 2. Get access to the SMS center (SMSC) or SMS gateway of a wireless carrier. Any SMS messages received will be forwarded to your computer / PC using a protocol / interface supported by the S MSC or SMS gateway. 3. Get access to the SMS gateway of an SMS service provider. Any SMS messages received will be forwarded to your computer / PC using a protocol / interface supported by the SMS gateway. 3.2.3.7 The 1st Way: Using a Computer to Receive SMS Messages through a Mobile Phone or GSM/GP RS Modem Receiving SMS messages through a mobile phone or GSM/GP RS modem has a major advantage over the other two ways -- wireless carriers usually do not charge any fees for receiving incoming SMS messages with their SIM cards. The disadvantage of receiving SMS messages this way is that a mobile phone or GSM/GP RS modem cannot handle
25
SMS BASED VOTING MACHINE a large amount of SMS traffic. One way to overcome this is to load balance the S MS traffic with a pool of mobile phones or GSM/GP RS modems. Each mobile phone or GS M/GPRS modem will have its own SIM card and mobile phone number. In terms of programming, sending and receiving SMS messages through a mobile phone or GSM/GP RS modem are similar. What you need to do is to send instructions (in the form of AT commands) to the mobile phone or GSM/GP RS modem. The following table lists the AT commands that are related to the receiving and reading of SMS messages: Table 3.5: AT Command RX AT command +CNMI +CMGL +CMGR +CNMA Meaning New message indications List messages Read messages New message acknowledgement
Below shows a simple example that demonstrates how to use AT commands and the HyperTerminal program of Microsoft Windows to read SMS text messages received by a GSM / GP RS modem or mobile phone. The lines in bold type are the command lines that should be entered in HyperTerminal. The other lines are responses returned from the GSM / GP RS modem or mobile phone. AT OK AT+CMGF=1 OK AT+CMGL=" ALL" +CMGL: 1,"REC our SMS tutorial. +CMGL: 2,"REC demo of SMS OK
26
READ","+7568501753", 06/11/11, 00:30:29+32" Hello, welcome to READ","+7568501753", 06/11/11, 00:32:20+32" A simple text messaging.
3.2.4 LCD
Fig 3.5: LCD 16*2 An HD44780 Character LCD is a de facto industry standard liquid crystal display (LCD) display device designed for interfacing with embedded systems. These screens come in a variety of configurations including 8x1, which is one row of eight characters, 16x2, and 20x4. The most commonly manufactured configuration is 40x4 characters, which requires two individually addressable HD44780 controllers with expansion chips as the HD44780 can only address up to 80 characters. These LCD screens are limited to text only and are often used in copiers, fax machines, laser printers, industrial test equipment, networking equipment such as routers and storage devices. Character LCDs use a standard 14-pin interface and those with backlights have 16 pins. The pin outs are as follows: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Ground VCC (+3.3 to +5V) Contrast adjustment (VO) Register Select (RS). RS=0: Command, RS=1: Data Read/Write (R/W). R/W=0: Write, R/W=1: Read Clock (Enable). Falling edge triggered Bit 0 (Not used in 4-bit operation) Bit 1 (Not used in 4-bit operation) Bit 2 (Not used in 4-bit operation) Bit 3 (Not used in 4-bit operation) Bit 4 Bit 5
27
SMS BASED VOTING MACHINE 13. 14. 15. 16. Bit 6 Bit 7 Backlight Anode (+) Backlight Cathode (-)
Character LCDs can operate in 4-bit or 8-bit mode. In 4 bit mode, pins 7 through 10 are unused and the entire byte is sent to the screen using pins 11 through 14 by sending 4-bits (nibble) at a time.
28
Description
The AT24C01A/02/04/08A/16A provides 1024/2048/4096/8192/16384 bits of serial electrically erasable and programmable read-only memory (EEPROM) organized as 128/256/512/1024/2048 words of 8 bits each. The device is optimized for use in many industrial and commercial applications where low-power and low-voltage operation are essential. The AT24C01A/02/04/08A/16A is available in space-saving 8-lead PDIP, 8-lead JEDEC SOIC, 8-lead Ultra-Thin Mini-MAP (MLP 2x3), 5-lead SOT23
(AT24C01A/AT24C02/AT24C04), 8-lead TSSOP, and 8-ball dBGA2 packages and is accessed via a Two-wire serial interface. In addition, the entire family is available in 2.7V (2.7V to 5.5V) and 1.8V (1.8V to 5.5V) versions.
PIN Diagram
29
CHAPTER 4 DATABASE
In this project the database of voting is maintained though software tool Visual basics 6.0 In this software tool there is full duplex interfacing between microcontroller, PC and GSM module.
(RAD) of graphical user interface (GUI) applications, access to databases using Data Access Objects, Remote Data Objects, or ActiveX Data Objects, and creation of ActiveX controls and objects. VBA is effectively the same language as Visual Basic but VBA-code is tied to Microsoft Office and can only run within that environment. The scripting language VBScript is a subset of Visual Basic. A programmer can create an application using the components provided by the Visual Basic program itself. Programs written in Visual Basic can also use the Windows API, but doing so requires external function declarations. Though the program has received criticism for its perceived faults, version 3 of Visual Basic was a runaway commercial success, and many companies offered third party controls greatly extending its functionality. The final release was version 6 in 1998. Microsoft's extended support ended in March 2008 and the designated successor was Visual Basic .NET (now known simply as Visual Basic).
and actions of those components, and writing additional lines of code for more functionality. Since default attributes and actions are defined for the components, a simple program can be created without the programmer having to write many lines of code. Performance problems were experienced by earlier versions, but with faster computers and native code compilation this has become less of an issue. Although VB programs can be compiled into native code executables from version 5 onwards, they still require the presence of runtime libraries of approximately 1 MB in size. Runtime libraries are included by default in Windows 2000and later, however for earlier versions of Windows, i.e. 95/98/NT, runtime libraries must be distributed together with the executable.
Fig 4.2: An empty form in Visual Basic 6.0 Forms are created using drag-and-drop techniques. A tool is used to place controls (e.g., text boxes, buttons, etc.) on the form (window). Controls have attributes and event
31
SMS BASED VOTING MACHINE handlers associated with them. Default values are provided when the control is created, but may be changed by the programmer. Many attribute values can be modified during run time based on user actions or changes in the environment, providing a dynamic application. For example, code can be inserted into the form resize event handler to reposition a control so that it remains centered on the form, expands to fill up the form, etc. By inserting code into the event handler for a key press in a text box, the program can automatically translate the case of the text being entered, or even prevent certain characters from being inserted. Visual Basic can create executable (EXE files), ActiveX controls, or DLL files, but is primarily used to develop Windows applications and to interface database systems. Dialog boxes with less functionality can be used to provide pop-up capabilities. Controls provide the basic functionality of the application, while programmers can insert additional logic within the appropriate event handlers. For example, a drop-down combination box will automatically display its list and allow the user to select any element. An event handler is called when an item is selected, which can then execute additional code created by the programmer to perform some action based on which element was selected, such as populating a related list. Alternatively, a Visual Basic component can have no user interface, and instead provide ActiveX objects to other programs via Component Object Model (COM). This allows for server-side processing or an add-in module. The runtime recovers unused memory using reference counting which depends on variables passing out of scope or being set to "Nothing", resulting in the very common problem of memory leaks. There is a large library of utility objects, and the language provides basic object oriented support. Unlike many other programming languages, Visual Basic is generally not case sensitive, although it will transform keywords into a standard case configuration and force the case of variable names to conform to the case of the entry within the symbol table. String comparisons are case sensitive by default. The Visual Basic compiler is shared with other Visual Studio languages (C, C++), but restrictions in the IDE do not allow the creation of some targets (Windows model DLLs) and threading models.
32
Statements tend to be terminated with keywords such as "End If", instead of using "{}"s to group statements.
Multiple variable assignments are not possible. A = B = C does not imply that the values of A, B and C are equal. The Boolean result of "Is B = C?" is stored in A. The result stored in A would therefore be either false or true. Boolean constant True has numeric value 1. This is because the Boolean data type is stored as a 16-bit signed integer. In this construct 1 evaluates to 16 binary 1s (the Boolean value True), and 0 as 16 0s (the Boolean value False). This is apparent when performing a Not operation on a 16 bit signed integer value 0 which will return the integer value 1, in other words True = Not False. This inherent functionality becomes especially useful when performing logical operations on the individual bits of an integer such as And, Or, Xor and Not. This definition of True is also consistent with BASIC since the early 1970s Microsoft BASIC implementation and is also related to the characteristics of CPU instructions at the time.
Logical and bitwise operators are unified. This is unlike some C-derived languages (such as Perl), which have separate logical and bitwise operators. This again is a traditional feature of BASIC.
Variable array base. Arrays are declared by specifying the upper and lower bounds in a way similar to Pascal and FORTRAN. It is also possible to use the Option Base statement to set the default lower bound. Use of the Option Base statement can lead to confusion when reading Visual Basic code and is best avoided by always explicitly specifying the lower bound of the array. This lower bound is not limited to 0 or 1, because it can also be set by declaration. In this way, both the lower and upper bounds are programmable. In more subscript-limited languages, the lower bound of the array is not variable. This uncommon trait does exist in Visual Basic .NET but not in VBScript. OPTION BASE was introduced by ANSI, with the standard for ANSI Minimal BASIC in the late 1970s.
33
Relatively
strong
integration
with
the Windows
operating
system and
the Component Object Model. The native types for strings and arrays are the dedicated COM types, BSTR and SAFEARRAY.
Banker's rounding as the default behaviour when converting real numbers to integers with the Round function.[7] ? Round (2.5, 0) gives 2,? Round(3.5, 0) gives 4. Integers are automatically promoted to reals in expressions involving the normal division operator (/) so that division of one integer by another produces the intuitively correct result. There is a specific integer divide operator (\) which does truncate.
By default, if a variable has not been declared or if no type declaration character is specified, the variable is of type Variant. However this can be changed with Deftype statements such as DefInt, DefBool , DefVar, DefObj, DefStr. There are
12 Deftype statements in total offered by Visual Basic 6.0. The default type may be overridden for a specific declaration by using a special suffix character on the variable name (# for Double, for Single, & for Long, % for Integer, $ for String, and @ for Currency) or using the key phrase as (type). VB can also be set in a mode that only explicitly declared variables can be used with the command Option Explicit.
With VB 6, you can create any program depending on your objective. For example, if you are a college or university lecturer, you can create educational programs to teach business, economics, engineering, computer science, accountancy, financial management, information system and more to make teaching more effective and interesting. If you are in business, you can also create business programs such as inventory management system, point-of-sale system, payroll system, financial program as well as accounting program to help manage your business and increase productivity. For those of you who like games and working as games programmer, you can create those programs as well. Indeed, there is no limit to what program you can create! There are many such programs in this tutorial, so you must spend more time on the tutorial in order to learn how to create those programs.
4.3.1 Form 1
Fig: 4.3: form1 Form 1 include two text windows one for user name and another for password. Two buttons are provided for ok to submit username and password and exit button for exit. If the password entered by admin is correct then only form 2 will be displayed.
4.3.2 Form 2
Form 2 is the main window of voting machine in software part for display, control and storage of database.
35
Fig 4.4: Form 2 before Voting c) Voter's Detail: In this text window voting detail of user (voter) is displayed.in the details voter NAME, PHONE NO. and CHOICE is displayed. d) Erase Button: It will erase the data store in EEPROM. e) Overall Voting: It will display the overall voting status from EEPROM. f) Send Data: It will send data to EEPROM and microcontroller. g) Logout: It will save current voting status and exit from window.
36
37
traces etched from copper sheets laminated onto a non-conductive substrate. When the board has only copper tracks and features, and no circuit elements such as capacitors, resistors or active devices have been manufactured into the actual substrate of the board, it is more correctly referred to as printed wiring board (PWB) or etched wiring board. Use of the term PWB or printed wiring board although more accurate and distinct from what would be known as a true printed circuit board, has generally fallen by the wayside for many people as the distinction between circuit and wiring has become blurred. Today printed wiring (circuit) boards are used in virtually all but the simplest commercially produced electronic devices, and allow fully automated assembly processes that were not possible or practical in earlier era tag type circuit assembly processes.
38
39
40
Fig 6.1:DB9 Connector Note that there are DB9-DB25 adapters for easily converting a DB9 plug into a DB25, and vice versa.
41
42
43
8.2 Advantages
a) Democracy: All and only the authorized voters can vote, and each eligible voter can vote no more than once. Voters can also choose not to vote. b) Privacy: All votes remain secret while voting takes place and each individual vote cannot be linked by any individual or authority to the voter who casts it. c) Accuracy: The voting result accurately reflects voters Choices. In this case, no vote can be altered, duplicated or eliminated without being detected. d) Fairness: No partial result is available before the final result comes out.
44
9.2 Limitations
a) Number of candidates is less. b) Major limitation is network problem. c) Less storage of data. d) Voting numbers are limited to three digits.
45
CHAPTER 10 CONCLUSION
We proposed a GSM mobile voting scheme, where the GSM authentication Infrastructure is used to provide voter authentication and improve voter mobility. Authentication is always a difficult requirement to fulfil for remote voting schemes, most of which apply a public-key based signature scheme for voter authentication. In our scheme, by using the existing GSM authentication infrastructure, the public-key overhead is largely reduced. Our scheme also enhances the security and provides more mobility and convenience to voters. Where the voters privacy is protected by applying a blind signature scheme. In this report, we presented the basic structure and protocol of our GSM based mobile voting system.
46
REFERENCES / BIBLIOGRAPHY
Muhammad Ali Mazidi , Janice Gillispie Mazidi, Rolin D. Mckinlay. Second edition, THE 8051 MICROCONTROLLER AND EMBEDDED SYSTEM K. J. Ayala. Third edition, The 8051 MICROCONTROLLER Tutorial on microcontroller: www.8051projects.net/microcontroller_tutorials/ Tutorial on LCD: www.8051projects.net/lcd-interfacing/
47
APPENDICES / ANNEXURE
1. 2. 3. 4. 5.
MICROCONTROLLER AT89S52 GSM MODULE MAX232 REGULATOR IC LED SIM 300 16PIN LM7805 RED GREEN
1 1 2 1
1 1
6. 7.
2 10F,16V 22pF 2 2 1 1
1 2
8. 9. 10. 11.
11.0592MHZ
48
12.
RESISTERS
1 1 1 1 1 1 1 1
4.00
1. 2. 3. 4. 5.
49
void delay(unsigned int a) { unsigned int i,j; for(i=0;i<a;i++) for(j=0;j<1275;j++); } void delay2(unsigned int a) { unsigned int i,j; for(i=0;i<a;i++) for(j=0;j<1;j++); } // delay 2 //delay 1
// lcd commands
50
SMS BASED VOTING MACHINE en=1; rs=0; rw=0; delay(2); en=0; } void lcd(unsigned char word) { lcddata=word; en=1; rs=1; rw=0; delay(2); en=0; } //Data writing of the Lcd //initialise of the LCD
void displaydata(unsigned char *word) { unsigned char x; for(x=0;word[x]!=0;x++) { lcd(word[x]); } } //Data writing of the LCD
51
{ SDA = 1;delay(1); SCL = 1;delay(1); SDA = 0;delay(1); SCL = 0;delay(1); } //starting of data writing in memory
void I2c_stop() { SCL = 0;delay(1); SDA = 0;delay(1); SCL = 1;delay(1); SDA = 1;delay(1); } void I2c_write(unsigned char a) { unsigned char i; for(i=0;i<8;i++) { SDA = ((a & 0x80)? 1:0 ); a <<=1; SCL = 1; delay(1) ; SCL = 0; delay(1) ; }
52
//checking MSB bit is '0' or'1' //used for sending the bit
SMS BASED VOTING MACHINE SCL = 1; delay(1); SCL = 0; } void write(unsigned char add,unsigned char val) { I2c_start(); delay(1); //reading from memory
I2c_write(val);delay(1); I2c_stop(); } unsigned char I2c_read() { unsigned char i,val; val = 0x00; for(i=0;i<8;i++) { val <<= 1; SCL = 1; val= val | SDA; delay2(1) ; SCL =0; delay2(1) ; } return (val); }
53
//Reset in_data
SMS BASED VOTING MACHINE unsigned char read(unsigned char add) { unsigned char val; I2c_start(); I2c_write(0xA0); I2c_write(add); I2c_start(); I2c_write(0xA1); val = I2c_read(); I2c_stop(); return (val) ; } delay2(1); delay2(1); delay2(1); delay2(1); delay2(1); delay2(1); //increment in value of candidate //writting in memory //calling of member functions
void main() { char x1,limit,num1,num,add,i,var,x; char records='0'; command(0x38); command(0x0C); SCON=0x50; TMOD=0x20; TH1=0xFD; main1: command(0x01); command(0x80); displaydata("Waiting 4 DATA");
//main funtion
//initializing of variable
main:
54
SMS BASED VOTING MACHINE num=0; while(1) { TR1=1; RI=0; while(1) { while(RI==0); msg[num]=SBUF; num++; if(msg[num-1]=='E') goto proceed; if(msg[num-1]=='B') goto proceed2; if(msg[num-1]=='N') goto proceed3; RI=0; } proceed3: command(0x01); command(0x80); displaydata("NEW DATABASE"); write(0,'0'); goto main1; proceed: TR1=1; RI=0;
55
SMS BASED VOTING MACHINE while(1) { while(RI==0); x1=SBUF; if(limit==1) notice[num1]=x1; if(x1=='#') break; num1++; if(x1=='*') { limit=1; num1=0; } RI=0; } if(notice[0]=='S') { command(0x01); command(0x80); displaydata("SAVING DATABASE"); records=read(0); records++; write(0,records); if(records=='1') add=1; if(records=='2')
56
SMS BASED VOTING MACHINE add=9; if(records=='3') add=17; if(records=='4') add=25; if(records=='5') add=33; for(i=0;i<8;i++) { write(add+i,notice[i+1]); } // variable for calculating candidate votes
command(0xc0); displaydata("SAVED"); delay(200); } command(0x01); command(0x80); displaydata("A B C D "); command(0xC0); lcd(notice[1]); lcd(notice[2]); lcd(' '); lcd(notice[3]); lcd(notice[4]); lcd(' '); lcd(notice[5]);
57
SMS BASED VOTING MACHINE lcd(notice[6]); lcd(' '); lcd(notice[7]); lcd(notice[8]); delay(100); goto main; proceed2: command(0x01); command(0x80); displaydata("READING DATA &"); command(0xc0); displaydata("TRANSMITTING...."); var=read(0); x=var-'0'; x=x*8; for(i=0;i<x;i++) { TI=0; SBUF=read(i+1); while(TI==0); } TI=0; SBUF='Z'; while(TI==0); command(0x01); command(0x80); displaydata("SENT");
58
//incrementing votes
59
SMS BASED VOTING MACHINE Private Sub Command1_Click() If MSComm2.PortOpen = False Then MSComm2.PortOpen = True End If MSComm2.Output = "AT+CMGD=1" & vbCrLf Sleep (100) //reading gsm command in inbox //open port 2
MSComm2.Output = "AT+CMGF=1" & vbCrLf End Sub Private Sub Command10_Click() start = InStr(Text6.Text, "+91") Text9.Text = Mid$(Text6.Text, start, 13) End Sub Private Sub Command2_Click() Timer1.Enabled = False Timer2.Enabled = False MSComm2.PortOpen = False End Sub Private Sub Command3_Click() Command8.Enabled = False Check1.Enabled = False MSComm1.PortOpen = False End Sub Private Sub Command4_Click() Command8.Enabled = True Check1.Enabled = True If MSComm1.PortOpen = False Then MSComm1.PortOpen = True
60
//enable timmer 1
//stoping port 2
//enabling command 8
SMS BASED VOTING MACHINE End If End Sub Private Sub Command5_Click() If c1 < 10 Then m1 = "0" Else m1 = "" End If If c2 < 10 Then m2 = "0" Else m2 = "" End If If c3 < 10 Then m3 = "0" Else m3 = "" End If If c4 < 10 Then m4 = "0" Else m4 = "" End If MSComm1.Output = "E*S" & m1 & c1 & m2 & c2 & m3 & c3 & m4 & c4 & "#" MsgBox "Data Sent to Microcontroller" Form2.Hide Form1.Show
61
//candidate 1 variable
//candidate 2 variable
//candidate 3 variable
//candidate 4 variable
SMS BASED VOTING MACHINE End Sub Private Sub Command6_Click() MSComm1.Output = "B" End Sub Private Sub Command7_Click() MSComm1.Output = "N" End Sub Private Sub Command9_Click() 'MSComm2.Output = "AT+CMGF=1" & vbCrLf 'MSComm2.Output = "AT+CMGR=1" & vbCrLf Timer1.Enabled = True End Sub Private Sub Command8_Click() If c1 < 10 Then m1 = "0" Else m1 = "" End If If c2 < 10 Then m2 = "0" Else m2 = "" End If If c3 < 10 Then m3 = "0" Else m3 = ""
62
SMS BASED VOTING MACHINE End If If c4 < 10 Then m4 = "0" Else m4 = "" End If
MSComm1.Output = "E*w" & m1 & c1 & m2 & c2 & m3 & c3 & m4 & c4 & "#" MsgBox "Data Sent to Microcontroller" End Sub Private Sub Form_Load() c1 = 0 c2 = 0 c3 = 0 c4 = 0 Command8.Enabled = False Check1.Enabled = False Timer1.Enabled = False Timer2.Enabled = False num = 0 NONAME = False End Sub Private Sub MSComm1_OnComm() If (MSComm1.CommEvent = comEvReceive) Then c = MSComm1.Input Text7.Text = Text7.Text & c End If
63
SMS BASED VOTING MACHINE If InStr(Text7.Text, "Z") > 0 Then Text8.Text = "OVERALL VOTING STATUS:" & vbCrLf & "DAY : A - B - C - D" & vbCrLf a = (Len(Text7.Text) - 2) / 8 x=1 For i = 0 To a Text8.Text = Text8.Text & "DAY" & (i + 1) & ": " & Mid$(Text7.Text, x, 2) Text8.Text = Text8.Text & "- " & Mid$(Text7.Text, x + 2, 2) Text8.Text = Text8.Text & "- " & Mid$(Text7.Text, x + 4, 2) Text8.Text = Text8.Text & "- " & Mid$(Text7.Text, x + 6, 2) & vbCrLf x=x+8 Next Text7.Text = "" End If End Sub Private Sub MSComm2_OnComm() If (MSComm2.CommEvent = comEvReceive) Then c = MSComm2.Input Text6.Text = Text6.Text & c End If If InStr(Text6.Text, "CMTI") > 0 Then Timer1.Enabled = True End If End Sub Private Sub Timer1_Timer() Text6.Text = "" MSComm2.Output = "AT+CMGR=1" & vbCrLf
64
SMS BASED VOTING MACHINE Timer1.Enabled = False Timer2.Enabled = True End Sub Private Sub Timer2_Timer() start = InStr(Text6.Text, "+91") Number1 = Mid(Text6.Text, (start + 3), 10) If InStr(Text6.Text, "VOTE") > 0 Then start = InStr(Text6.Text, "VOTE") choice1 = Mid(Text6.Text, (start + 4), 1) start = InStr(Text6.Text, "PASS") PASSWORD = Mid(Text6.Text, (start + 4), 4) findname If NONAME = True Then GoTo proceed End If If InStr(Text1.Text, Number1) = 0 Then Text1.Text = Text1.Text & Number1 & "---" & Name1 & "---" & choice1 & vbNewLine choice = Val(choice1) If choice = 1 Then c1 = c1 + 1 ElseIf choice = 2 Then c2 = c2 + 1 ElseIf choice = 3 Then c3 = c3 + 1 ElseIf choice = 4 Then c4 = c4 + 1 End If
65
SMS BASED VOTING MACHINE If c1 > c2 And c1 > c3 And c1 > c4 Then Label8.Caption = " 1" ElseIf c2 > c1 And c2 > c3 And c2 > c4 Then Label8.Caption = " 2" ElseIf c3 > c1 And c3 > c2 And c3 > c4 Then Label8.Caption = " 3" ElseIf c4 > c1 And c4 > c2 And c4 > c3 Then Label8.Caption = " 4" Else Label8.Caption = " -" End If Text2.Text = c1 Text3.Text = c2 Text4.Text = c3 Text5.Text = c4 MSComm2.Output = "AT+CMGS=" & Chr(34) & Number1 & Chr(34) & vbCrLf Sleep (200) MSComm2.Output = "YOUR VOTING IS SUCCESSFUL. THANK YOU." & Chr(26) If (Check1 = vbChecked) Then '''''''''''''''' If c1 < 10 Then m1 = "0" Else m1 = "" End If If c2 < 10 Then m2 = "0"
66
SMS BASED VOTING MACHINE Else m2 = "" End If If c3 < 10 Then m3 = "0" Else m3 = "" End If If c4 < 10 Then m4 = "0" Else m4 = "" End If //data send to flash memory //variable for candidate voting //variable for candidate voting
MSComm1.Output = "E*w" & m1 & c1 & m2 & c2 & m3 & c3 & m4 & c4 & "#" 'MsgBox "Data Sent to Microcontroller" 'MsgBox "Data Sent to Microcontroller" End If Else //sms send for voying done
MSComm2.Output = "AT+CMGS=" & Chr(34) & Number1 & Chr(34) & vbCrLf Sleep (200) MSComm2.Output = "YOUR VOTING IS ALREADY DONE. VOTING ONCE IS ONLY PERMITTED." & Chr(26) End If proceed: Text6.Text = ""
67
SMS BASED VOTING MACHINE End If MSComm2.Output = "AT+CMGD=1" & vbCrLf Timer2.Enabled = False End Sub Public Sub findname() If Number1 = "7568501753" And PASSWORD = "0000" Then Name1 = "Mr. RAHUL" ElseIf Number1 = "8963040102" And PASSWORD = "1111" Then Name1 = "Mr. VIJAY" ElseIf Number1 = "8963040102" And PASSWORD = "2222" Then Name1 = "Mr. VIJAY" ElseIf Number1 = "8963040102" And PASSWORD = "3333" Then Name1 = "Mr. VIJAY" ElseIf Number1 = "8963040102" And PASSWORD = "4444" Then Name1 = "Mr. VIJAY" Else MSComm2.Output = "AT+CMGS=" & Chr(34) & Number1 & Chr(34) & vbCrLf Sleep (200) MSComm2.Output = "YOUR VOTING IS UNSUCCESSFUL. Mobile Number/Password Verification Error." & Chr(26) NONAME = True End If End Sub //password verification
68
SMS BASED VOTING MACHINE :10038300D2A11202C6D2A01202CAC2A11202CAC2CA :04039300A00202CAF8 :10039700C2A01202C6C2A11202CAD2A01202CAD2B7 :0403A700A10202CAE3 :02029D008F7A56 :10029F00E4F9E57A30E703D38001C392A1E57A252B :1002AF00E0F57A1202C4C2A01202CA09B908E31219 :0402BF0002C4C2A013 :0102C3002218 :1002EA008F788D791203831202C67FA012029D12A3 :1002FA0002C6AF7812029D1202C6AF7912029D128F :05030A0002C60203978A :10033200E4F579F9E57925E0F579D2A0A2A1E433D3 :100342004279120279C2A012027D09B908E6AF7998 :010352002288 :02021B008F78DA :10021D001202767FA012029D120279AF7812029D12 :10022D001202791202767FA112029D120279120337 :0B023D0032A907120279120397AF01EB :010248002293 :100003007577307F3812035A7F0C12035A75985054 :10001300758920758DFD1203537BFF7A0179B71221 :10002300030FE4FFD28EC2983098FD74682FF8A6B0 :10003300990F74672FF8E6FE64456026EE644270FC :100043000302014DEE644E6004C29880DB12035339 :100053007BFF7A0179C612030F7D30E4FF1202EAB7 :1000630080B4D28EC2983098FDAF99E572B401077F
70
SMS BASED VOTING MACHINE :1000730074082573F8A607EF6423600F0573BF2A7E :1000830006757201E4F573C29880DBE5086453706A :10009300761203537BFF7A0179D312030FE4FF1225 :1000A300021B8F770577AD77E4FF1202EAE577B499 :1000B3003103757401E577B43203757409E577B4D8 :1000C3003303757411E577B43403757419E577B4A4 :1000D3003503757421E4F575E5742575FF740925F9 :1000E30075F8E6FD1202EA0575C3E5756480948828 :1000F30040E67FC012035A7BFF7A0179E312030FB4 :100103007FC87E001202CA1203537BFF7A0179E98A :1001130012030F7FC012035AAF09120371AF0A1201 :10012300036CAF0B120371AF0C12036CAF0D120310 :1001330071AF0E12036CAF0F120371AF1012037184 :100143007F647E001202CA0200251203537BFF7AEA :100153000179F612030F7FC012035A7BFF7A0279EB :100163000512030FE4FF12021BEF24D0F57675F09E :1001730008A4F576E4F575C3E5766480F8E575645F :1001830080985012C299E57504FF12021B8F9930B3 :1001930099FD057580E1C29975995A3099FD12034D :1001A300537BFF7A02791612030F7F647E001202DB :0401B300CA02001963 :030000000203AB4D :0C03AB00787FE4F6D8FD75817B0200032A :10024900BB010CE58229F582E5833AF583E022506A :1002590006E92582F8E622BBFE06E92582F8E222B4 :0D026900E58229F582E5833AF583E49322CE :00000001FF
71