Plan - Soldier Pile Wall Without P. G. A.: Timber Lagging Sizes
Plan - Soldier Pile Wall Without P. G. A.: Timber Lagging Sizes
1'-0"
CEMENT CONCRETE 2'-0" CHIP OUT SHAFT BACKFILL
GUTTER SEE BR. SHT. SP4 TO PLACE LAGGING.
3"
BACKFILL ALL VOIDS BEHIND
LAGGING WITH GRAVEL
BACKFILL FOR WALL.
(TYP.)
5'-0"
PREFABRICATED
W SECTION TYP. DRAINAGE MAT (TYP.)
W.P.
15°(TYP.) LIMITS OF
3'-0"
EXCAVATION PRIOR FRACTURED FIN FINISH
HP
CONCRETE FASCIA REMAINING PORTION SHEAR STUDS
H
NGT OF SOLDIER PILE SHAFT AT 1'-0" (TYP.)
D LE . PANELS
BON
HP/3
1'-0"
3:1
SLO
*
PE 2" MIN. BEARING LENGTH.
GROUND LINE
FOR DIAMETER OF FULL BEARING.
SOLDIER PILE SHAFT, PGA
¢ PILE
SEE BR. SHT. SP2 FINAL GROUND LINE
è
TIMBER LAGGING SIZES
í í
DEPTH (FT) SIZE
GRAVEL BACKFILL FOR WHERE NECESSARY CHIP OUT CDF
0 - 9 4 x WALL AS REQUIRED TO PLACE LAGGING.
3" CLR.
9 - 18 6 x BACKFILL VOIDS BEHIND LAGGING
WITH GRAVEL BACKFILL FOR WALL
18 - 30 8 x 8"ø XS PIPE (TYP.)
PREFABRICATED
4 x - OPTIONAL 4 x 8, 4 x 10 OR 4 x 12 DRAINAGE MAT (TYP.)
6 x - OPTIONAL 6 x 8, 6 x 10 OR 6 x 12 W SECTION TYP.
* USE CONTROL DENSITY FILL WHEN PLACED
8 x - OPTIONAL 8 x 8, 8 x 10 OR 8 x 12
TYPICAL SECTION
¢ PILE
IN THE DRY. USE LEAN PUMPABLE CONCRETE
WHEN PLACED IN THE WET.
NOTES TO DESIGNER: SHOWN FOR SOLDIER PILE WITH P.G.A.
SIMILAR FOR SOLDIER PILE WITHOUT P.G.A.
í DEPTHS AND SIZES SHOWN ARE ONLY AN EXAMPLE. FILL IN
THE TABLE ACCORDING TO THE EARTH PRESSURE DIAGRAM P.G.A.= PERMANENT GROUND ANCHOR REMAINING PORTION
AND RECOMMENDATIONS FROM THE GEOTECHNICAL SERVICES BRANCH, OF SOLDIER PILE SHAFT
BASED ON LRFD TIMBER DESIGN FOR PERMANENT LAGGING.
LAGGING IN SERVICE
8.1-A3-2B
0
36 MONTHS OR LONGER