1. Objective:
The students should be able to: Operate Vapour Liquid Separation Experiment using a Packed Column Distillation Process Unit. Analyze the sample for the Top and Bottom Product by Refractometer to obtain the Refractive Index in order to determine their respective composition. To obtain the time when the Vapour Liquid Separation is nearly finish.
2. Introduction:
Distillation is one of the important unit operations in many chemical industries and has been used from the inception of chemical and process industry. Distillation is used for the separation of components in a liquid mixture of volatile constituents. The Distillation Column is usually a vertical column where the liquid and vapour phases of the mixture are made to mix and approach equilibrium. Packed Bed Distillation Colum ns are sometimes used to carry out the Distillation in the industry. Distillation is a process of separating the components of a solution by the application of heat when the vapour produced by boiling the solution has a different composition to that of the solution. If the vapour formed is condensed and subsequently reboiled it will produce, yet again, a vapour of different composition. Repeated boiling of condensed vapours will ultimately produce a product of desired quality rich in concentration of one of the components of the original solution. Distillation takes place in a Distillation Column which, in essence, comprises a Boiler, a Column and a Vapour Condensed. The Boiler provides the heat for vapour generation; within the column rising vapours continually mix with liquid flowing down the column, condense and are reboiled until vapour of required composition leaves the column and condenses in the Vapour Condenser to be removed as Liquid Product. A certain proportion of this condensate is returned to the column, called Reflux, the proportion being a major influence on the quality of the product achieved. Since this experiment use Batch Distillation plant, therefore, it can be said that this is a process whereby a specific quantity of a liquid mixture is separated into its components. The technique is used extensively in laboratories and small scale production plants where the equipment is often used for separating several different mixtures of where if only one mixture is separated, the mixture is not produced continuously. The relatively high capital cost of Continuous Distillation Plants with their sophisticated control systems, often results in smaller companies operating Batch Distillation plants. Batch Distillation is particularly useful for separating liquid mixtures contaminated with solids which would otherwise foul a continuous plant. This unit comprises of a Reboiler operating on the Thermosyphon principle heated by either steam or electrically. Process vapours enter at the base of the column which contains a Packed Column containing 10 mm Raschig Rings, ( the vapour temperatures entering and leaving the column are measured by temperature indicators TI 3 and TI1 respectively as shown in the Process Flow Diagram of this unit. ) and are condensed at the top of the column in a Condenser. The Distillate is separated into Reflux, which is passed back to the column and Product, which passes through a Product Cooler and then through a Graduated Pipe Section. The Product may then be collected or returned back to the Reboiler. Vapours leaving at the top of the column are totally condensed to Liquid Distillation in the Overhead Condenser and pass to the Reflux Control Flow Meters RI 1A and RI 1B. RI 1A indicates the quantity of Distillate returned to the column via the three-way valve while RI 1B indicates the quantity of Distillate removed as Product. A Process Flow Diagram for Packed Column Distillation Process Unit is as shown in the next page.
The flow rates of liquids should not exceed the maximum of the rates shown in the flow meter. Do not allow the water pressure to exceed 2.0 bar maximum as indicated by PI.2. Always maintain V8 in the open position during atmospheric operation (avoid system pressurizing). Dont isolate cooling water until the heating has been shut down (at least 10 minutes). Dont switch on the immersion heater with the level in the reboiler below the heater elements or when the reboiler is empty. Dont return the product distillate collected to the reboiler vessel when the equipment is in operation. Do not allow the liquid level to rise much above the top graduation on the tube before the stop valves V2 and V3 are opened. Dont drain the liquid in reboiler vessel until is cold. Do not touch the hot components of the unit.
Prepare between 30 to 40 litres of 10 % to 20 % mixture of Ethanol in Water by mixing appropriate quantities of the Industrial Grade of Ethanol in Distilled Water. Refer to the diagram of the equipment in the lab for better / accurate view. Ensure that the concentration of feed in the reboiler vessel is correct and that the liquid level is at the vessel equator. Ensure valves V1, RCV1, V3, V4, V5, V6, V7, V9 and FCV2 are closed. Ensure valves V2, V8 and V10 are open. Start fill in Ethanol / Water mixture up to the desired level (Ask Lecturer / Technician). Slowly open the cooling water to the condenser (max 2.0 bar). Make sure water is indeed flowing through it. Check water flows to the drain from the Cooling Water outlets. Do not start the experiment until the Cooling Water flow is visible in the outlets to the drain. Ensure that the Bottom Product sampling valve V5 and Top Product sampling valve V4 is closed. Ensure that the Reboiler Vessel is already charged with the Ethanol Water mixture through the Charge Port (Refer to the diagram). Otherwise top up with the Ethanol Water mixture through the Charge Port (Refer to instructor / technician). Ensure that the concentration of feed in the Reboiler vessel is correct and that the liquid level is at the Vessel Equator (Refer to Lecturer / Technician). The Reboiler Vessel should never be filled with liquid above the maximum level indicated. The level should never recede below the minimum level while on operation. Close the Reflux Adjustment Valve RCV 1 and valve below Product Cooler V2. Obtain a sample of Ethanol Water mixture from the Reboiler through the Sampling Port and test its composition using Refractometer and given graph of Refractive Index Vs Mole Fraction of Ethanol in Liquid. Turn on the main power control switch. Turn on the power switch of the heater. Switch on electrical supply (green heater on button). Set heater controller HC.4 to maximum setting (About 30A / 230 V). When distillate liquid is seen to flow through RI.A1, reduce the heat input and set HC.4 (About 20 A). Allow a period of 15 minutes for the equipment to maintain thermal equilibrium with surroundings. During this period observe HC.4. The unit is now ready to be used for an experiment.
Observe the flow rate at R1. Adjust the valve for Reflux Ratio adjustment to ensure that the Reflux Ratio is maintained at 1.0. The concentration of the samples drawn is measured using the Refractive Index method. Record the reading of temperatures for every 5 minutes. Readings are recorded in the provided table of results.
5. Result:
Time (Min) 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85