High Efficiency

TECHNICAL CATALOGUE

2011

www.lafert.com

three-phase LV Motors

CONTENTS

General information

Product range

Standards and regulations

10

Conditions of installation

14

Mechanical design

16

Electrical design

25

Order data

31

THREE-PHASE MO TO RS

33

Terminal boxes

34

Connection diagrams

36

[ I]

[ T]

Three-phase cage motors driven


by frequency converter

38

Spare parts

39

Type designation

40

Electrical Data

41

Dimensions

54

[1]

Indice

[ TI ]]

General information

[23]

[3]

General information - Technical Catalogue 1031/11

[ I]

PRODUC T RA NG E

Lafert Group product range


In the next few pages we offer a detailed overview of our manufacturing program of AC
induction motors.
The main scope of our core business is the development of dedicated solutions that
improves our Customers product design, thereby giving our customers a competitive
advantage. The core business of our Company stands on the ability to adapt and engineer
our standard Product design to any specific market demand.
Lafert's range of products is divided in five product sectors:

ENERGY EFFICIENT Motors, high efficiency motors, IE2 code


in the range 56 to 315, IE3 code in the range 90 to 160

CUSTOMISED Motors, special and customised motors,


brake motors and single-phase motors

HIGH PERFORMANCE Motors, high performance,


permanent magnet motors and generators as well as the
relevant drives

SERVO Motors & Drives, brushless servomotors and drives


for industrial automation

LIFT Motors, synchronous gearless machines with


permanent magnet rotor for elevators

General information - Technical Catalogue 1031/11

PRODUCT RANGE

[ I]

ENERGYEFFICIENT MOTORs
High Efficiency Three-phase Motors
Motors conforming to the higher efficiency standards for Europe, North America and
Australia.
For Europe, Lafert offers its AMHE and AMPE range of AC induction motors, whose
efficiency values are conforming to IE2 and IE3 requirements according to IEC 6003430;2008.
Lafert motors for the North American market comprise the AMH and AMPH range. These
machines meet the higher efficiency demands of the USAs Department of Energys Energy
Policy Act (EPAct) and are conforming to EISA (Energy Indipendence and Security Act) that
imposes strict levels of minimum efficiency. It is illegal to import Motors into the USA and
Canada that do not comply with this standard.

IE2
IE3

In addition to EPAct requirements, these motors are a recognised component verified by


Underwriters Laboratories and carry the UL approved logo.

The standard design includes the following basic features to give a high level of flexibility:
Multi Mount Construction for an easy change of terminal box position
Terminal box rotates by 90 to allow cable entry from any direction
Easy-to-change flanges with over-sized and smaller-sized dimensions
Provision for oil seal at Drive End

[4]

[5]

General information - Technical Catalogue 1031/11

[ I]

PRODUC T RA NG E

CUSTOMISED MOTORS
Dedicated and customised executions
Lafert specialises in customised solutions for non-standard motor applications. We are
considered as a market leader in this field and have built a reputation for excellence for this
core activity over the past 45 years.
The range of specials includes both electrical and mechanical variants:
Extended stainless steel motor shafts for the fan industry
Motors for pumping applications
Complete Tailor made designs
Customised flange and shaft for gear motors
Electrical design to meet specific duty requests
Specific wound motors for worldwide electrical supply
Motor design to meet special environmental requests (Smoke and heat exhaust
ventilation, Dust Ignition for Zone 22, Non Sparking Exn)

Brake Motors
Laferts brake motors (3 and single phase) are engineered to give safety, versatility and long
service life. The motors mechanical design is specific for brake motors in order to avoid any
risk of failure.
The three brake options available with AC or DC brake coil can fit any application.
The AMBY and AMBZ ranges have a very strong design and may meet any heavy duty
application. The AMBY range is also available with low noise brake, specific for theatres.
The compact AMS range is the ideal solution for woodworking equipment manufacturers,
packaging machines manufacturers, as well as small crane manufacturers.
As well as meeting industry specific safety requirements, the motors are also failsafe
machines: a combination that ensures maximum machine safety.

General information - Technical Catalogue 1031/11

PRODUCT RANGE

[ I]

HIGH PERFORMANCE MOTORS


High Performance Motors with permanent magnet rotor
A differentiator with Sensorless Permanent Magnet Motors is the premium high efficiency
level and the compact design. The efficiency level normally stands over 90% all along the
motors speed range.
This Product must be driven by a frequency converter, that can also be on-board as an
integral drive.
Major applications are the Pump and Fan Industry, Textile Machinery Manufacturers,
Gearbox Manufacturers, Traction Systems for microcars and scooters; this Product can be
produced as a Generator for Wind Energy.
A separate catalogue is available.

[6]

[7]

General information - Technical Catalogue 1031/11

[ I]

PRODUC T RA NG E

SERVO MOTORS & DRIVES


Brushless Servo Motors
Among the few independent manufacturers of Servo Motors in the market, Lafert can
supply a wide range of standard and tailor made products for Industrial Automation.
The whole manufacturing process is integrated within Lafert manufacturing facilities, giving
an excellent flexibility to specific market demands, as well as a high level of cost-efficiency.
Brushless Standard Motors
Direct Drive Motors
Low Inertia Motors
Compact Motors
A separate catalogue is available.

Servo Drives
Our products are manufactured according to the criterion of adaptability and flexibility. This
ensures an easy and fast set-up, by means of the most advanced hardware and software
technologies.
Every device always ensures the highest reliability and safety, because it is subject to strict
tests in different load and climatic conditions.
A separate catalogue is available.

General information - Technical Catalogue 1031/11

PRODUCT RANGE

[ I]

LIFT MOTORs
Gearless Machines for Elevators
The LIFT range allows the manufacturing of systems where the traction machine is inside the
elevator shaft, so there is no need for a machine room, with obvious space and cost savings
and a more rational layout of the all components.
LIFT is permanent-magnet gearless synchronous machine with torque up to 660 Nm for
systems up to 1,275 kg.
The compact and heavy-duty motor comes with the following features:
Very small dimensions
High Efficiency
High comfort
No maintenance
Low noise level
A separate catalogue is available.

Our Strengths:
Customer Designs
Exact Engineering
In Partnership
with the Customer

[8]

[9]

General information - Technical Catalogue 1031/11

[ I]

sta nda rds a nd regul ati ons

The strictness of our quality


control assures the flawless
operation and reliability of our
products.
That our quality scale fulfils your
demands is confirmed by the
certificate awarded by the CERMET,
a Certification body authorized by
ACCREDIA.

CE Marking
Our motors comply with the requirements of the following international standard:
IEC 60034
as well as with the following European Directives: Low Voltage Directive 2006/95/EC, the
EMC-Directive 2004/108/EC and Directive on the restriction of the use of certain hazardous
substances in electrical and electronic equipment (RoHS) 2002/95/EC.
The above named products comply with the requirements of the EC Directive Machines
2006/42/EC. In accordance with this Directive induction motors are components and
intended solely for integration into other machines.
Commissioning is forbidden until conformity of the end product with this Directive is
proved!
The

IE1
IE2
IE3

symbol was applied for the first time in 1995.

The safety instructions in the Operation Manual of the manufacturer and EN


60204-1 have to be observed.
Harmonized efficiencies to IEC 60034-30;2008 - IE1, IE2 and IE3 code.
Efficiency testing method IEC 60034-2-1;2007
All standard three-phase motors with standard rating included in this catalogue comply
with efficiency class IE1 and bear the corresponding label on the rating plate.
For efficiency at 50%, 75% and full load, please refer to the electrical data tables.

General information - Technical Catalogue 1031/11

sta ndards and regulati ons

[ I]

New International Efficiency Levels for Motors: IE Codes


The International standard IEC 60034-30;2008 states the new efficiency levels IE1, IE2 and
IE3 for electric motors, ensuring an international common base for motor designing and
classification, as well as for national legislative activities.
The efficiency measurement method for motors has also been reviewed.
The new standard IEC 60034-2-1;2007 provides for test conditions and efficiency
measurement methods which are more accurate and replaces the previous standard EN
60034-2;1996.
By comparing results from the same motor, the efficiency levels measured according to the
new test method are lower than those with the old method.
The efficiency levels provided for by the standard for single speed, three-phase brake
motors included -50 Hz or 50/60 Hz, motors with rated output between 0,75 kW and 375
kW, 2, 4 or 6 poles, on the basis of continuous duty operation S1 or intermittent periodic
duty operation S3 are the following:
IE1 = Standard Efficiency
IE2 = High Efficiency
IE3 = Premium Efficiency
However, IEC 60034-30 states only the requirements for the efficiency levels, thus creating
shared measures worldwide. It does not state the motors to be supplied or the minimum
efficiency level. This depends on any regional laws that are applicable.
EUROPE EcoDesign EuP directive (2005/32/EC)
The EcoDesign EuP directive (2005/32/CE) states the ecodesign requirements for energyusing products.
It is the Commission Regulation (EC) 640/2009 that specifies the efficiency requirements for
electric motors and that introduces in all countries of the European Community the
obligation of the IE2 minimum efficiency level as from 16th June 2011.
At further dates, progressively higher minimum efficiency requirements will be established.
The IE3 level will come in from 2015-2017.
The scope of the Commission Regulation includes single speed, three-phase 50 Hz or 50/60
Hz, squirrel cage asynchronous motors with rated output between 0.75 kW and 375 kW,
2, 4 or 6 poles, on the basis of continuous duty operation S1.
Motors to be exclusively exported out of the EU (machine distributors or manufacturers)
may be produced and distributed with IE1 efficiency level even after 16th June 2011.
To that end, a statement will have to be made to the manufacturer.

[10]

[11]

General information - Technical Catalogue 1031/11

[ I]

sta nda rds a nd regul ati ons

UNITED STATES, CANADA EISA Energy Independence and Security Act, 2007
The Energy Independence and Security Act, 2007 (EISA) imposes in the USA and Canada
Nema Premium Efficiency (IE3) as minimum level of efficiency as from 19th December
2010.
EISA, which replaces the current 1992 Energy Policy Act (EPAct) legislation, sets out new
efficiency restrictive limits for a wide range of three-phase motors, including brake motors
with power ratings from 1 to 500 HP.

Efficiency values according to IEC 60034-30;2008


Efficiency standard calculation: IEC 60034-2-1;2007

IE1 code
Output
Standard Efficiency
kW 2 poles 4 poles 6 poles

























0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
355
375

72.1
75.0
77.2
79.7
81.5
83.1
84.7
86.0
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93.0
93.3
93.5
93.7
94.0
94.0
94.0
94.0
94.0

72.1
75.0
77.2
79.7
81.5
83.1
84.7
86.0
87.6
88.7
89.3
89.9
90.7
91.2
91.7
92.1
92.7
93.0
93.3
93.5
93.8
94.0
94.0
94.0
94.0
94.0

70.0
72.9
75.2
77.7
79.7
81.4
83.1
84.7
86.4
87.7
88.6
89.2
90.2
90.8
91.4
91.9
92.6
92.9
93.3
93.5
93.8
94.0
94.0
94.0
94.0
94.0

IE2 code
High Efficiency
2 poles 4 poles 6 poles
77.4
79.6
81.3
83.2
84.6
85.8
87.0
88.1
89.4
90.3
90.9
91.3
92.0
92.5
92.9
93.2
93.8
94.1
94.3
94.6
94.8
95.0
95.0
95.0
95.0
95.0

79.6
81.4
82.8
84.3
85.5
86.6
87.7
88.7
89.8
90.6
91.2
91.6
92.3
92.7
93.1
93.5
94.0
94.2
94.5
94.7
94.9
95.1
95.1
95.1
95.1
95.1

General information - Technical Catalogue 1031/11

75.9
78.1
79.8
81.8
83.3
84.6
86.0
87.2
88.7
89.7
90.4
90.9
91.7
92.2
92.7
93.1
93.7
94.0
94.3
94.6
94.8
95.0
95.0
95.0
95.0
95.0

IE3 code
Premium Efficiency
2 poles 4 poles 6 poles
80.7
82.7
84.2
85.9
87.1
88.1
89.2
90.1
91.2
91.9
92.4
92.7
93.3
93.7
94.0
94.3
94.7
95.0
95.2
95.4
95.6
95.8
95.8
95.8
95.8
95.8

82.5
84.1
85.3
86.7
87.7
88.6
89.6
90.4
91.4
92.1
92.6
93.0
93.6
93.9
94.2
94.6
95.0
95.2
95.4
95.6
95.8
96.0
96.0
96.0
96.0
96.0

78.9
81.0
82.5
84.3
85.6
86.8
88.0
89.1
90.3
91.2
91.7
92.2
92.9
93.3
93.7
94.1
94.6
94.9
95.1
95.4
95.6
95.8
95.8
95.8
95.8
95.8

sta ndards and regulati ons

[ I]

The motors comply with the relevant standards and regulations, especially:
Ttle

IEC

EU
CENELEC

D
DIN/VDE

I
CEI/UNEL

GB
BS

F
NFC

E
UNE

Electrical
General stipulations
60034-1 EN 60034-1 DIN EN 60034-1 CEI EN 60034-1 4999-1 51-200
for electrical machines
4999-69 51-111
Rotating electrical machines: 60034-2 HD 53 2
DIN EN 60034-2 CEI EN 60034-2 4999-34 51-112
methods for determining losses
and efficiency using tests
Standard method for determing 60034-2-1
losses and efficiency from tests
Efficiency classes of single
60034-30
speed, three-phase, cageinduction motors (IE-code)
Terminal markings and
60034-8 HD 53 8 S4 DIN VDE 0530-8 CEI EN 60034-8 4999-3 51-118
direction of rotation of
rotating electrical machines
Starting performance
60034-12 EN 60034-12 DIN EN 60034-12 CEI EN 60034-12 4999-112
Standard voltages
60038
HD 472 S1 DIN IEC 60038
CEI 8-6
Insulating materials
60085
DIN IEC 60085
CEI EN 60085

UNE EN 60034-1
UNE EN 60034-2

20113-8-96

UNE EN 60034-12

Mechanical
Dimensions and
60072
DIN EN 50347
UNEL 13113
output ratings
Mounting dimensions and
60072
DIN 42673-1
UNEL 13113
4999-10 51-105
relationship frame sizes-output
51-110 51-104
ratings, IM B3
Mounting dimensions and
60072
DIN 42677-1
UNEL 13117
20106-2-74
relationship frame sizes-output
ratings, IM B5
Mounting dimensions and
60072
DIN 42677-1
UNEL 13118
4999-10 51-105
relationship frame sizes-output
51-110 51-104
ratings, IM B14
Cylindrical shaft ends
60072
HD 231
DIN 748-3
UNEL 13502
4999-10 51-111
for electric motors
Degrees of protection
60034-5 EN 60034-5 DIN EN 60034-5 CEI EN 60034-5 4999-20 EN60034-5
Methods of cooling
60034-6 EN 60034-6 DIN EN 60034-6 CEI EN 60034-6 4999-21
Mounting arrangements
60034-7 EN 60034-7 DIN EN 60034-7 CEI EN 60034-7 4999-22 51-117
Noise limits
60034-9 EN 60034-9 DIN EN 60034-9 CEI EN 60034-9 4999-51 51-119
Mechanical vibration
60034-14 EN60034-14 DIN EN 60034-14 CEI EN 60034-14 4999-50 51-111
Mounting flanges
DIN 42948
UNEL 13501
Tolerances of mounting
DIN 42955
UNEL 13501/
and shaft extensions
13502
Classification of
60721-2-1
DIN IEC 60721-2-1 CEI EN 60721-1
environmental conditions
Mechanical vibration;
ISO 8821
DIN ISO 8821
balancing

UNE EN 50347
1980

UNE EN 50347

20111-5
EN 60034-6
EN 60034-7
EN 60034-9
EN 60034-14

Motors to special regulations:


Motors with UL, CSA and cURus approval (performance data on request)

[12]

[13]

General information - Technical Catalogue 1031/11

[ I]

C ONDI T IONS OF INSTALLATION

The motors are designed for operation at altitudes 1000 m above sea-level and at ambient
temperatures of up to 40 C. Exceptions are indicated on the rating plate.
Permissible temperature rises to various standards
Standard/Regulation
Temperature
of coolant



C

Permissible temperature rise in K


(measured by resistance method)
Temperature class
B
F
H

VDE 0530 part 1


International IEC 34-1
Britain BS 2613
Canada CSA
USA NEMA and ANSI
Italy CEI
Sweden SEN
Norway NEK
Belgium NBN
France NF
Switzerland SEV
India IS

80
80
80
80
80
80
80
80
80
80
80
80

40
40
40
40
40
40
40
40
40
40
40
40

105
105
105
105
105
105
105
105
105
105
105
-

125
125

on
request

The motors conform to degree of protection IP 55 to IEC 60034-5. Higher protection on


request.
The standard design for horizontal mounting is suitable for indoor and protected outdoor
installation, climate group MODERATE (see page 18) (temperature of coolant -20 to +40 C).
For unprotected outdoor installation or severe climatic conditions (moisture category wet,
climate group WORLDWIDE, extremely dusty site conditions, aggressive industrial
atmosphere, danger of storm rain and coastal climate, danger of attack by termites, etc.),
as well as vertical mounting, special protective measures are recommended, such as:

Protective cowl (for vertical shaft-down motors)


For vertical shaft-up motors additional bearing seal and flange drainage
Special paint finish
Treatment of winding with protective moisture-proof varnish
Anti-condensation heating (possibly winding heating)
Condensation drain holes

The special measures to be applied have to be agreed with the factory once the conditions
of installation have been settled.

The corresponding conditions of installation have to be clearly indicated in the order.

General information - Technical Catalogue 1031/11

C ON DITIONS OF INSTALLATION

[ I]

Tolerances
For industrial motors to EN 60034-1, certain tolerances must be allowed on guaranteed
values, taking into consideration the necessary tolerances for the manufacture of such
motors and the materials used. The standard includes the following remarks:
1. It is not intended that guarantees necessarily have to be given for all or any of the items
involved. Quotations including guaranteed values subject to tolerances should say so, and
the tolerances should be in accordance with the table.
2. Attention is drawn to the different interpretation of the term guarantee. In some
countries a distinction is made between guaranteed values and typical or declared values.
3. Where a tolerance is stated in only one direction, the value is not limited in the other
direction.
Values for

Tolerance

Efficiency ()
(by indirect determination)

- 0.15 (1 - ) at PN 150 kW
- 0.1 (1 - ) at PN > 150 kW


1 - cos
, minimum 0.02, maximum 0.07
Power factor (cos )
6

Slip (s)
20 % of the guaranteed slip at PN 1 kW
(at rated load and at working temperature)
30 % of the guaranteed slip at PN < 1 kW
Breakaway starting current (IA)
(in the starting circuit envisaged)

+ 20 % of the guaranteed starting current


(no lower limit)

Breakaway torque (MA)


- 15 % and + 25 % of the guaranteed breakaway torque


(+ 25 % may be exceeded by agreement)

Pull-up torque (MS)

- 15 % of the guaranteed value

Pull-out torque (MK)


- 10 % of the guaranteed value


(after allowing for this tolerance, MK/MN not less than 1.6)

Moment of inertia (J)

10 % of the guaranteed value

Mechanical tolerances
According to IEC 60072-1, the following tolerances on mechanical dimensions of electric
motors are permitted:
Parameter

Code

Tolerances

Shaft height
H


D-DA
Diameter of shaft end1)

Hub key width
F-FA
Flange spigot
N

1)

up to 250
over 250
from 11 to 28 mm
from 38 to 48 mm
from 55 to 100 mm
up to 132
over size 132

-0,5 mm
-1 mm
j6
k6
m6
h9
j6
h6

Centerings holes in shaft extension to DIN 332 part 2

[14]

[15]

General information - Technical Catalogue 1031/11

[ I]

ME C H ANIC AL DESIGN

Degrees of protection
Degrees of mechanical protection for machines are designated in accordance with IEC
60034-5 by the letters IP and two characteristic numerals.
First numeral: Protection against contact
and ingress of foreign bodies

IP

0

1


Second numeral:
Protection against ingress of water

Description

IP

No special protection

Description
No special protection
Protection against vertically
falling water drops (condensation)

Protection against solid foreign 1



bodies larger than 50 mm
(Example: inadvertent contact with
the hand)

Protection against solid foreign 2

bodies larger than 12 mm
(Example: inadvertent contact with
the fingers)

Protection against solid foreign 3



bodies larger than 2.5 mm
(Example: Wires, tools)

Protection against waterspray at


up to 60 from vertical

Protection against solid foreign 4



bodies larger than 1 mm
(Example: Wires, bands)

Protection against water splashed


from any direction

Protection against dust 5


(harmful deposits of dust)

Protection against water


projected by a nozzle from
any direction

Complete protection against dust

Protection against heavy seas or


water projected in powerful jets

Protection when submerged


between 0.15 and 1 m.

Protection when continuously


submerged in water at conditions
agreed between the
manufacturer and the user

General information - Technical Catalogue 1031/11

Protection against dropping water


when inclined by up to 15

MECHANICAL DESIGN

[ I]

Mounting arrangements
Mounting arrangements for rotating electrical machines are designated according to IEC
60034-7, Code I (in brackets Code II).
Our motors are available with the mounting arrangements listed below, depending on
design and frame size. Motors with aluminium frame are equipped with removable feet that
allow easy change of mounting arrangement.
Foot mounting

Flange mounting

Motors without endshield

IM B3 (IM 1001)

IM B5 (IM 3001)
Flange type A to
DIN 42 948 at
drive end

IM B9 (IM 9101)
without endshield
and without
ball bearings
on drive end

IM B6 (IM 1051)

IM V1 (IM 3011)
Flange type A to
DIN 42 948 at
drive end

IM V8 (IM 9111)
without endshield
and without
ball bearings
on drive end

IM B7 (IM 1061)

IM V3 (IM 3031)
Flange type A to
DIN 42 948 at
drive end

IM V9 (IM 9131)
without endshield
and without
ball bearings
on drive end

IM B8 (IM 1071)

IM B35 (IM 2001)


Flange type A to
DIN 42 948 at
drive end

IM B15 (IM 1201)


without endshield
and without
ball bearings
on drive end

IM V5 (IM 1011)

IM B14 (IM 3601)


Flange type C to
DIN 42 948 at
drive end

IM V6 (IM 1031)

IM V18 (IM 3611)


Flange type C to
DIN 42 948 at
drive end

IM B34 (IM 2101)


Flange type C to
DIN 42 948 at
drive end

IM V19 (IM 3631)


Flange type C to
DIN 42 948 at
drive end

It is essential to state the desired mounting arrangement when ordering, as the constructive
design depends partly on the mounting arrangement.

[16]

[17]

General information - Technical Catalogue 1031/11

[ I]

ME C H ANIC AL DESIGN

Materials
Motor parts

Frame size Material

Motor housing

56 - 160
180 - 315

Aluminium alloy
Cast iron

Endshield


Flanged endshield


Fan cover



Fan


Terminal box


56 - 160
180 - 315

Aluminium alloy*
Cast iron

56 - 160
180 - 315

Aluminium alloy*
Cast iron

56 - 112
56 - 112
132 - 315

Plastics
Sheet steel (optional)
Sheet steel

56 - 315
56 - 160

Plastics
Aluminium alloy (optional)

56 - 112
56 - 112
132 - 160
180 - 315

Plastics
Aluminium alloy (optional)
Aluminium alloy
Cast iron

* Cast iron option for 112-132

Paint finish
Normal finish
Suitable for climate group Moderate to IEC 60721-2-1, e.g. indoor and outdoor
installation.
For short periods: up to 100 % rel. humidity at temperatures up to +30 C.
Continuously: up to 85 % rel. humidity at temperatures up to +25 C.
Standard paint color: RAL 9005.
Special finish K1
Suitable for climate group Worldwide to IEC 60721-2-1, e.g. outdoor installation in
corrosive chemical and marine atmospheres.
For short periods: up to 100 % rel. humidity at temperatures up to +35 C.
Continuously: up to 98 % rel. humidity at temperatures up to +30 C.

General information - Technical Catalogue 1031/11

MECHANICAL DESIGN

[ I]

Bearings
Classification of bearings (standard design) 1)
Bearings for standard design have permanent lubrication
Ball bearings to ISO15 (DIN 625)


Frame size
No. of
 
poles

56
2 + 4
63
2 + 4
71
2 - 8
80
2 - 8
90
2 - 8
100
2 - 8
112
2 - 8
132
2 - 8
160
2 - 8
180
2 - 8
200
2 - 8
225
2 - 8
250
2 - 8
280
2 - 8
315 S/M/L
2
315 S/M/L
4 - 8
1)

Drive end
6201-2Z
6202-2Z
6203-2Z
6204-2Z C3
6205-2Z C3
6206-2Z C3
6306-2Z C3
6208-2Z C3
6309-2Z C3
6311 C3
6312 C3
6313 C3
6314 C3
6316 C3
6317 C3
NU319 C3

Non-drive end
6201-2Z
6202-2Z
6203-2Z
6204-2Z C3
6205-2Z C3
6206-2Z C3
6306-2Z C3
6208-2Z C3
6309-2Z C3
6311 C3
6312 C3
6313 C3
6314 C3
6316 C3
6317 C3
NU319 C3

With regard on bearings for special design, consult us

Lubrication note
Permanent lubrication up to 160 frame
180 frame up with regreasing facility lubrication nipple is a flat M10x1 to DIN 3404
Roller bearings
Roller bearings available as an option. Please consult us.

Bearing arrangement
Frame size

Bearing drive end

Bearing non-drive end

Spring-loaded

56 - 160 Standard motors


180 - 315 Standard motors

Non-locating bearing
Locating bearing

Non-locating bearing
Non-locating bearing

Non-drive end
Non-drive end

[18]

[19]

General information - Technical Catalogue 1031/11

[ I]

ME C H ANIC AL DESIGN

Belt drive
The data apply only to the normal drive end shaft extension of IM B3 motors with one
speed.
Calculation of belt drive:

19120 P k
FR =
D1 n


FR = Radial shaft load in N

P = Output in kW

n = Speed in min-1

D1 = Pulley diameter in m

k = Belt tension factor, varying with the type of belt, assumed to be approximately:
3-4
for normal flat belt without idler pulley
2-2.5 for normal flat belt with idler pulley
2.2-2.5 for V-belt
For exact data apply to the belt manufacturer.

Maximum permissible axial forces without additional radial forces*



Frame
size
3000

min -1

kN

56
0.16
63
0.19
71
0.23
80
0.32
90
0.34
100
0.48
112
0.48
132 S
0.80
132 M
0.78
160 M
0.84
160 L
0.82
180
0.82
200
0.82
225
1.10
250
1.00
280
1.70
315
2.00

Horizontal shaft
1500
1000
min -1
min -1
kN
kN

750
min -1
kN

0.21
0.26
0.33
0.44
0.48
0.68
0.68
1.13
1.09
1.18
1.15
1.15
1.15
1.60
1.60
1.90
14.00

-
-
0.37
0.50
0.54
0.77
0.77
1.28
1.24
1.33
1.30
1.30
1.30
2.40
2.50
2.90
14.00

-
-
0.33
0.46
0.49
0.70
0.70
1.16
1.13
1.21
1.18
1.18
1.18
1.90
2.00
2.40
14.00

Vertical shaft - force upwards


3000
1500
1000
750
min -1 min -1
min -1 min -1
kN
kN
kN
kN
0.18
0.21
0.26
0.34
0.38
0.54
0.56
1.00
0.99
1.18
1.18
1.18
1.18
2.10
2.30
2.90
3.60

0.22
0.28
0.35
0.47
0.47
0.74
0.75
1.32
1.30
1.52
1.51
1.51
1.51
2.60
2.70
3.10
8.00

-
-
0.36
0.48
0.53
0.76
0.77
1.36
1.33
1.56
1.55
1.55
1.55
2.90
3.20
3.60
9.20

-
-
0.39
0.53
0.58
0.83
0.84
1.47
1.45
1.68
1.67
1.67
1.67
3.40
3.70
3.70
7.40

Values for 50 Hz. For service on 60 Hz, reduce values by 10%


* Consult according to direction of force

General information - Technical Catalogue 1031/11

Vertical shaft - force downwards


3000
1500
1000
750
min -1
min -1
min -1 min -1
kN
kN
kN
kN
0.15
0.17
0.21
0.29
0.31
0.43
0.40
0.61
0.58
0.50
0.46
0.46
0.46
0.30
0.20
0.15
1.00

0.19
0.24
0.30
0.41
0.44
0.62
0.60
0.93
0.89
0.83
0.79
0.79
0.79
0.70
0.60
0.30
1.90

-
-
0.31
0.43
0.46
0.64
0.62
0.97
0.92
0.87
0.82
0.82
0.82
1.00
1.10
0.80
2.40

0.34
0.47
0.51
0.71
0.69
1.08
1.03
0.99
0.94
0.94
0.94
1.50
1.50
1.00
2.90

MECHANICAL DESIGN

[ I]

Permissible radial forces


Without additional axial force (Ball bearings)
Nominal life = 20.000 h (Lh10)
FR = permissible radial force in kN in load point corresponding to half shaft extension
 Size

3000
min -1
kN

1500
min -1
kN

1000
min -1
kN

750
min -1
kN


56
63
71
80
90
100
112
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 M
250 M
280 S
280 M
315 S/M
315 L

0.34
0.38
0.46
0.59
0.67
0.92
0.93
1.35
1.40
1.55
1.58
3.00
3.02
5.24
6.11
6.79
7.76
7.79
7.02
7.03

0.42
0.48
0.58
0.83
0.94
1.29
1.30
1.90
1.97
2.17
2.22
4.44
4.47
6.85
7.80
8.82
11.90
11.99
11.35
11.37

-
-
0.67
0.86
0.97
1.33
1.34
1.96
2.03
2.23
2.29
4.55
4.58
8.01
9.09
10.31
13.87
13.97
13.40
13.35

0.73
0.94
1.07
1.47
1.48
2.15
2.23
2.46
2.52
4.76
4.79
8.94
10.12
11.45
15.44
15.55
15.13
15.09

[20]

[21]

General information - Technical Catalogue 1031/11

[ I]

ME C H ANIC AL DESIGN

Special endshields and flanges


Full range of smaller sized and over sized flanges
Frame
size

Smaller sized Flange


IMB14
IMB5 1)

Over sized Flange


IMB5
IMB14


56
63
71
80
90 S-L
100 L
112 M
132 S
132 M
160 M
160 L

NA
56
56-63
63-71
63-71
71-80
80 2)-90 2)
112 2)
112
NA
NA

NA
71 3)
80-90
NA
100 3)
NA
132 7)
NA
160 4)
NA
NA

NA
56
63
63-71
71-80
90
90
112
112
132
132

63
71-80
80-90
90-100
100-112
132
132
160 1) 4)
160
NA
NA

Possibility to fit over sized bearings:

Availability of aluminium endshields and flanges


with steel insert

Frame
size

Frame Endshield Endshield


size
DE
NDE
IMB5

IMB3


56
NA
63
6203-6205
71
6204-6205
80
6205-6206
90 S-L
6206
100 L
6306
112 M
6208
132 S
6308-6309
132 M
6308-6309
160 M
NA
160 L
NA

IMB5

IMB14

NA
6203
6204-6205
6205-6206
6206-6308
6306-6208
6208
6308 4)
6308-6309
6310
6310

NA
6203-6205
6204-6205
6205-6206
6206
6306
6208
6308 4)
6309
6310
6310


71
80
90 S-L
100 L
112 M
132 S
132 M
160 M
160 L

A
A
A
A
A
NA
NA
NA
NA

A
A
A
A
A
NA
NA
NA
NA

A
A
NA
A
A
NA
A 5)
NA
NA

IM B14
NA
A
NA
NA
NA
NA
NA
NA
NA

For higher output (progressive motor) please consult us


Availability of cast iron endshields and flanges
Frame
size

Endshield
DE


71
80
90 S-L
100 L
112 M
132 S
132 M
160 M
160 L

NA
A 6)
A 6)
A 6)
A 6)
A
A
A
A

Endshield
NDE
IMB5
IM B14
NA
A 6)
A 6)
A 6)
A 6)
A
A
A
A

NA
NA
NA
NA
NA
A
A
A
A

A Available
NA Not available
1) Not available for all motor ratings; consult us
2) Cast iron endshield with radial slotted holes
3) Not interchangeable with standard execution

NA
NA
NA
NA
NA
A
A
A
A
4)

DE

Regreasing device
NDE
IM B5
IM B14

NA
NA
NA
NA
NA
NA
A
A
A

NA
NA
NA
NA
NA
NA
A
A
A

NA
NA
NA
NA
NA
A
A
A
A

NA
NA
NA
NA
NA
A
A
A
A

Cast iron endshield


Only with oversized bearing (6308)
6) Special mechanical design
7) Only with oversized bearing (6208)
5)

MECHANICAL DESIGN

[ I]

Cooling
Surface cooling, independent of the direction of rotation.
Motors type AM available without internal fan as type AG, e.g. for installation in a directed
air stream (outputs on request).
Vibration
The amplitude of vibration in electric motors is governed by EN 60034-14 Mechanical
vibration of rotating electrical machines with shaft heights 56 and larger - methods of
measurement and limits.
Standard motors are designed to vibration grade A (normal). Vibration grade B is available
at extra cost.
Pole-changing motors in Dahlander connection can only be supplied in vibration
grade A.
Rotors are at present dynamically balanced with half key fitted as per DIN ISO 8821.
Other balancing only on request.
The motors are identified as follows:

"H" or "blank" means balanced with half key

"F" means balanced with full key

"N" means no key
Position and dimensions of key
Frame Poles
size

d x l1

b x h

l2

l3

56
63
71
80
90
100
112
132
160
180
200
225
2
225
4
250
2
250
4
280
2
280
4
315
2
315
4

9 x 20
11 x 23
14 x 30
19 x 40
24 x 50
28 x 60
28 x 60
38 x 80
42 x 110
48 x 110
55 x 110
55 x 110
60 x 140
60 x 140
65 x 140
65 x 140
75 x 140
65 x 140
80 x 170

3 x 3
4 x 4
5 x 5
6 x 6
8 x 7
8 x 7
8 x 7
10 x 8
12 x 8
14 x 9
16 x 10
16 x 10
18 x 10
18 x 11
20 x 10
18 x 11
20 x 12
18 x 11
22 x 14

15
15
20
30
40
50
50
70
100
90
90
90
110
110
110
110
140
125
160

2.5
4
5
6
6
6
6
6
6
5
5
5
5
5
5
5
5
5
5

10.2
12.5
16
21.5
27
31
31
41
45
51.5
59
59
64
64
74.5
69
85
69
85

l2

l3

l1

Dimensions in mm.
For larger shafts in special design the dimensions l2 and l3 are maintained.

[22]

[23]

General information - Technical Catalogue 1031/11

[ I]

ME C H ANIC AL DESIGN

Anti-condensation heater
On request, motors which due to strong temperature fluctuations are exposed to
condensation during standstill, can be fitted against surcharge with an anti-condensation
heater (space heater).
For supply voltage and heater rating please refer to the following table:

Frame size

112 - 160
180 - 225
250 - 280
315

Supply voltage (V)


110
110
110
110

or
or
or
or

Heater rating per motor (W)

230
230
230
230

25
50
50
75

During operation of the motor, the heating must be switched off.

Noise
The noise level of an electrical machine is determined by measuring the sound pressure level
in accordance with curve A of the sound level meter to EN 60651 and is indicated in dB (A).
The permitted noise levels of electrical machines are fixed in EN 60034-9 (IEC 34-9). The noise
level of our motors is well below these limit values.
Air-borne sound measurements are carried out in an anechoic testing chamber to EN 21680ISO 1680.
Speed corresponding to a mains frequency of 50 Hz and the number of poles.
Noise levels
The noise values listed below refer to 50 Hz at rated voltage with a tolerance of up to + 3
dB(A). Values for pole-changing motors on request. For 60 Hz supply values are 3-5 dB(A)
higher.
Sound pressure level LpA and sound power level LWA for three-phase single-speed motors with
dimensions and output ratings to IEC 60072
Frame 2 pole 4 pole 6 pole 8 pole
LWA LpA
LWA LpA
LWA LpA
size
LWA LpA














56
63
71
80
90
100
112
132
160
180
200
225
250
280
315

57
58
61
72
74
78
80
81
87
99
101
103
104
105
105

48
49
52
60
62
66
68
72
74
87
89
91
93
94
94

47
47
51
60
61
62
65
71
75
88
91
92
93
98
98

38
38
42
48
49
50
53
59
62
76
79
80
80
86
86

General information - Technical Catalogue 1031/11

49
52
58
62
65
69
71
85
87
89
89
95
95

40
40
46
51
53
57
58
73
75
77
77
83
83

47
54
58
58
64
69
83
85
86
86
91
91

35
42
46
46
52
56
71
73
75
75
80
80

ELECTRI CAL DESIGN

[ I]

Rated voltage
For the rated voltage of the motors, EN 60034-1 allows a tolerance of 5 %. According to
IEC 60038, the mains voltages may have a tolerance of 10 %.
Therefore the three-phase motors are designed for the following rated voltage ranges
(exceptions are shown in the data tables):

Mains voltage to DIN IEC 38

Rated voltage range of motor

230 V 10%
400 V 10%
690 V 10%

218-242 V 5%
380-420 V 5%
655-725 V 5%

Within the rated motor voltage range, the permissible maximum temperature is not
exceeded. When the motors are operated at the limits of the voltage tolerance, the
permissible overtemperature of the stator winding may be exceeded by 10 K.
Nameplates are marked with the maximum rated currents within the stated voltage ranges.
For brake motors, for motors in 500 V, 50 Hz design, and all not standard voltages, no
voltage range is marked. The voltage tolerances to EN 60034-1 apply.
Rated frequency
Three-phase 50 Hz motors can also be operated on 60 Hz mains, provided the mains
voltage increases proportionally to the frequency. The relative values for starting and
breakaway torque remain nearly unchanged and slightly increase for the starting current.
The rated speed increases by the factor 1.2 and output by factor 1.15. Should a motor
designed for 50 Hz be operated at 60 Hz without the voltage being increased, the rated
output of the motor cannot be increased. Under these operating conditions, rated speed
increases by factor 1.2. The relative values for starting and breakaway torque are reduced
by factor 0.82 and for starting current by factor 0.9.
Additionally to the voltage range for 50 Hz operation, three-phase single-speed motors (not
brake motors) are also marked with the voltage range for 60 Hz operation.

Nameplate examples:

[24]

[25]

General information - Technical Catalogue 1031/11

[ I]

E LE C T RIC AL DE SIGN

Rated current
For three-phase motors the rated currents listed in the data tables apply to an operating
voltage of 400 V. The conversion to other operating voltages, with output and frequency
remaining unchanged, is to be made as follows:
Nominal voltage (V)
Conversion factor x lN
Rated torque

Rated torque in Nm = 9550 x

230
1.74

380
1.05

400
1.0

440
0.91

500
0.80

660
0.61

690
0.58

Rated power in kW
Rated speed in min-1

Output
The outputs stated in this catalogue are for constant load in continuous running duty S1
according to EN 60034-1, based on an ambient temperature of 40 C and installation at
altitudes up to 1000 m above sea level.
For severe operating conditions, e.g. high switching rate, long run-up time or electric
braking, a thermal reserve is necessary, which could call for higher thermal class or the use
of a motor with a higher rating. In these cases we recommend to enquire with detailed
information on the operating conditions.
Overload
At operating temperature three-phase motors are capable of withstanding an overload for
15 seconds at 1.5 times the rated torque at rated voltage. This overload is according to EN
60034-1 and will not result in excessive heating.
Utilizing thermal class F, motors can be operated continuously with an overload of 12 %.
Nevertheless this is not valid for motors which to catalogue are utilized to thermal class F.
Connection
Motor output
at 50 Hz

230 V
400 V Y

400 V
690 V Y

under 3 kW
4 to 5.5 kW
7.5 kW

standard
on request
standard
standard
on request standard

500 V Y

500 V

690 V

on request
on request
on request

on request
on request
on request

on request
on request

General information - Technical Catalogue 1031/11

ELECTRI CAL DESIGN

[ I]

Insulation and temperature rise


Class F insulation to EN 60034-1 is used throughout.
In standard design motors are intended for operation at 40 C ambient temperature
with class B temperature rise only, with an overtemperature limit of 80 K. This also
applies for the rated voltage range to IEC 60038. Exceptions are shown on the data
tables.
Temperature rise (T*) and maximum temperatures at the hottest points of the winding
(Tmax) according to the temperature classes of EN 60034-1.

Class B
Class F
Class H

T*
80 K
105 K
125 K

Tmax
125 C
155 C
180 C

*Measurement by resistance method

Output reduction at ambient temperatures over 40 C



Ambient temperature
Class B Reduction of nominal output to approx.

45 C
95 %

50 C
90 %

55 C
85 %

60 C
80 %

When a winding is utilized to temperature class F (105K), no output reduction is required


up to an ambient temperature of 55 C. This does not apply to motors which in their
standard design are already utilized to thermal class F.

Installation at altitudes of more than 1000 m above sea level (see also EN 60034-1)
Altitude of installation

2000 m

3000 m

4000 m

At 40C ambient temperature and thermal class B


Rated output reduced to approx.

92 %

84 %

76 %

At 40C ambient temperature and thermal class F


Rated output reduced to approx.

89 %

79 %

68 %

Full nominal output to data tables with thermal class B


and ambient temperature of

32 C

24 C

16 C

Full nominal output to data tables with thermal class F


and ambient temperature of

30 C

19 C

9 C

[26]

[27]

General information - Technical Catalogue 1031/11

[ I]

E LE C T RIC AL DE SIGN

Starting rate
The permissible number of starts per hour can be taken as given in the table below,
provided the following conditions are met.
Additional moment of inertia moment of inertia of the rotor: load torque rising with the
square of the speed up to nominal torque; starts at even intervals.

Shaft height
56
80
112
160
200
250

-
-
-
-
-
-

71
100
132
180
225
315

Permissible No. of starts per hour for 2p


= 2
= 4
6
100
60
30
15
8
4

250
140
60
30
15
8

350
160
80
50
30
12

For permissible number of starts for pole-changing motors please consult us, indicating the
complete operating conditions.

General information - Technical Catalogue 1031/11

ELECTRI CAL DESIGN

[ I]

Thermal protection
The decision on a particular type of thermal protection should be taken according to the
actual operating conditions. Motors may be protected by means of current-dependent
thermal protection switches, overcurrent relays and temperature detectors.
Thermal protection is possible as follows:
Thermal protection switch with bimetal release
Thermistor protection with semiconductor temperature detectors (PTC) in the stator
winding in connection with release (if required, with additional motor protection switch).
Bimetal temperature detector as N/C or N/O in the stator winding (if required, with
additional motor protection switch).
Resistance thermometer for monitoring winding and bearing temperature.
Should protection of the motor be required, we install protection switch with bimetal
release (semiconductor temperature detectors on request).
Operating specifications
Thermal cut-out
NORMALLY OPEN
N/O TYPE
Ti = Activation temperature
Tr = Reset temperature

Tr

Ti

Operating specifications
of the thermistors

NORMALLY CLOSED

N/C TYPE
Ti = Activation temperature
Tr = Reset temperature

PTC TYPE
Ti = Activation temperature

OHM

Resistance

Tr

Ti

Ti

[28]

[29]

General information - Technical Catalogue 1031/11

[ I]

E LE C T RIC AL DE SIGN

Examples of connection
Protection method

Protection against:

Motor protection switch with thermal and Overload in continuous service


Locked rotor
electromagnetic overcurrent release

Contactor with overcurrent relay


Thermistor protection and fuse

in service against:
Overload in continous service
Long starting and braking periods
High switching rate

in case of fault against:


Obstruction of cooling
Increased ambient temperature
Single-phase operation
Frequency fluctuations
Switching against locked rotor

Semiconductor temperature detector


with release

in service against:
Overload in continous service
Long starting and braking periods
High switching rate

in case of fault against:


Obstruction of cooling
Increased ambient temperature
Single-phase operation
Frequency fluctuations
Switching against locked rotor

Auxiliaries
Encoder (standard design)
Pulses per revolution
Max outputs frequency
Power supply
Electronics
Current consumption without load
Outputs


Pulse displacement between outputs
Protection
Max speed
Operating temperature

200-2048
100 kHz
5Vdc
line driver
100 mA
2 signals with rectangular pulses A, B
2 signals with inverted rectangular pulses A, B
zero pulse and inverted zero pulse
90
IP 54
3000 (6000) min -1
-10C 85C

General information - Technical Catalogue 1031/11

ORDER DATA

[ I]

Motors for normal continuous duty (S1) and normal operating conditions
Quotation (if submitted)
Quantity
Designation

No./Date
Units
Type

Output (for pole-changing motors, outputs referred to speeds)

kW

Speed (for pole-changing motors, outputs referred to speeds)

min-1

Direction of rotation (viewed on drive end)


Mounting arrangement (to IEC 60034-7)
Degree of protection, motor/terminal box (to IEC 60034-5)
Mains voltage

Mains frequency

Hz

Method of starting (direct-on-line or Y-)


Location of terminal box
Machine to be driven
Dimensions of cables, if these differ from those allocated by VDE 0100, referred to an
ambient temperature of 40 C, or when aluminium conductors are used. It should be stated
when parallel connected conductors are used.
Additional information for special designs
Second or non-standard shaft extension
Radial sealing ring
Paint coating
Corrosive protection
Vibration level
Anti-condensation heating
Temperature detectors
Noise requirements
Mechanical or electrical brake
Special stipulations

[30]

[31]

General information - Technical Catalogue 1031/11

[ I]

ORDE R DATA

Additional information for special duties and difficult operating conditions


S 2: ... min (short-time duty)
S 3: ... % - ... min (intermittent duty)
S 4: ... % - JM ... kgm2 - Jext ... kgm2 (intermittent duty with starting)
S 5: ... % - JM ... kgm2 - Jext ... kgm2 (intermittent duty with electric braking)
S 6: ... % - min (continuous-operation periodic duty with intermittent load)
S 7: .JM ... kgm2 - Jext ... kgm2 (continuous-operation periodic duty with electric braking)
S 8: .JM ... kgm2 - Jext ... kgm2 (continuous-operation periodic duty with speed changes)
S 9: ... kW (continuous duty with non-periodic load and speed variations).
For this duty type suitable full load values should be taken as the overload concept.
S10: p/t .... r .... TL (Duty with discrete constant loads).
Starting conditions (no-load or loaded starting)
Shock loads
Load torque curve during run-up (characteristic)
Moment of inertia (Jext) referred to the motor shaft

kgm2

Description of the type of drive (direct coupling, flat or V-belt,


straight or helical gears, sprocket, crank, eccentric cam, etc.)
Radial force (or diameter of drive element)

Direction of force and point of application (distance from shaft shoulder or width
of drive element)

mm

Axial force and direction of application (pull/thrust)

Ambient conditions (e.g. increased humidity, dust accumulation, corrosive gases or vapours,
increased or extremely low ambient temperature, outdoor installation, installation at
altitudes over 1000 m above sea level, external vibration, etc.)

General information - Technical Catalogue 1031/11

[ T]

THREE-PHASE MOTORS

[32]

[33]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

ME C H ANIC AL DESIGN

Terminal boxes
The location of the terminal box in standard design is on top; on the right or on the left are
possible.
Motors 71-160 frame size have removable feet for easy change of terminal box position
For motors with mountings IM B6, IM B7, IM B8, IM V5, IM V6 the location of the terminal
box is related to an IM B3 mounting.
The position of the entry openings can be adjusted to suit the existing connection facilities
by turning through 90. Should special accessories be used (temperature detectors, anticondensation heating, etc.) please enquire.
For motors in standard design, the cable gland does not belong to our scope of delivery.
For plastic terminal boxes, only plastic glands may be used (shock protection).
When using screened leads, a metal terminal box is required.
Direction of cable entries

Frame size
Degree of
Max. cable
Terminal

protection
Thread for cable entry
section
thread


Metric 1)
Pg 2)
mm 2
56 - 71
80
90 - 112
132
160
180
200
225
250 - 280
315

IP 55
IP 55
IP 55
IP 55
IP 55
IP 55
IP 55
IP 55
IP 55
IP 55

1 x M16/1 x M20
1 x Pg 11/1 x Pg 13.5
1 x M25/1 x M20
1 x Pg 13.5/1 x Pg 16
1 x M25/1 x M20
1 x Pg 13.5/1 x Pg 16
2 x M32
2 x Pg 21
2 x M40
2 x Pg 29
2 x M40/1 x M20
2 x M40/1 x M25
2 x M50/1 x M25
2 x M50/1 x M25
2 x M63/1 x M25 3)

2.5
2.5
4
4
16
35
35
50
50
185

1) Pitch

1.5
thread to DIN 40 430 (on request)
3) Terminal box with unscrewable cable entry plate
2) Pg

Three-Phase Motors - Technical Catalogue 1031/11

M4
M4
M5
M5
M6
M8
M8
M10
M10
M12

Max. external
cable diam.
mm
12
16
16
20
28
28
34
34
40
48

[ T]

MECHANICAL DESIGN

g4

Standard design
A

91
91
91
111
111
111
111
133
150
187
233
233
260
260
320

93
93
93
116
116
116
116
133
150
162
186
186
218
218
280

Material

F rame g4
size h

56
63
71
80
90
100
112
132
160
180
200
225
250
280
315

Terminal box on top

g4

98
103
112
129
138
145
161
198
238
268
300
335
366
408
530

Plastic UL 94 V0
Plastic UL 94 V0
Plastic UL 94 V0
Plastic UL 94 V0
Plastic UL 94 V0
Plastic UL 94 V0
Plastic UL 94 V0
Aluminium
Aluminium
Cast Iron
Cast Iron
Cast Iron
Cast Iron
Cast Iron
Cast Iron

Terminal box at the side


Special design

g4

Frame
size h

56
63
71
80
90
100
112
180
200
225
250
280

left

1)

Material

100
105
114
139
148
155
171
285
310
334
375
409

94
94
94
110
110
110
110
209
241
272
272
g4
272

94
94
94
110
110
110
110
220
246
254
254
254

Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
Cast Iron
Cast Iron
Cast Iron
Cast Iron
Cast Iron

g4

right
On frame size 56-63 the terminal box is
supplied displaced towards the non-drive
end

1)

[34]

[35]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

E LE C T RIC AL DE SIGN

Connection diagrams
Windings of standard three-phase single speed motors can be connected either in star or
delta connection.
Star connection
A star connection is obtained by connecting W2, U2, V2 terminals to eachother and the U1,
V1, W1 terminals to the mains. The phase current and voltage are:
Iph = In ; Uph = Un / 3
where In is the line current and Un the line voltage referred to the star connection.
Delta connection
A delta connection is obtained by connecting the end of a phase to the beginning of the
next phase.
The phase current Iph and the phase voltage Uph are:
Iph = In / 3 ; Uph = Un
where In and Un are referred to the delta connection.

U1

U1

W1

L1

V1

W1

V1

W2

U2

V2

W2

U2

V2

U1

V1

W1

U1

V1

W1

L2

L3

Star connection

L1

L2

L3

Delta connection

Star-delta starting
Star-delta starting allows a peak current reduction. It can be used only when the reduced
starting torque obtained is higher than the resistant torque. Actually, it should be noted that
the torque of an induction squirrel-cage motor is directly proportional to the square of the
voltage. Motors whose rated voltage with delta connection corresponds to the mains
voltage, can be started with the star-delta method.
All motors can be supplied with windings designed for star-delta starting (for example: 400
V / 690 V Y).

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

ELECTRI CAL DESIGN

Pole-changing motors
Standard pole-changing motors are designed for single voltage and direct-on-line starting.
When the ratio between the two speeds is from 1 to 2, the standard motors have one single
winding (Dahlander connection). For the other speeds, the motors have two separate
windings.
AM/AMV - two separate windings
L1

L3

L2

2U

2V

2W

2U

2V

2W

1U

1V

1W

1U

1V

1W

High speed
L1

L2

L3

Low speed

AM - Dahlander connection / YY
L1

1U

2V

1W

2U

2V

2W

1U

1V

1W

2U

L2

L3

2U

2V

2W

1U

1V

1W

2W

1U

1V

2U

Low speed

1V

1W

2W
L1

L2

2V

High speed

L3

AMV - Dahlander connection Y/ YY


L1

L2

L3

2U

1U
2U

2V

2W

1U

1V

1W

2U

2V

2W

1U

1V

1W

2W

2V

1U

2U

1W

Low speed

1V
1W

2W

1V

L1

L2

L3

2V

High speed

[36]

[37]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

ca ge m oto r s d ri ven by frequency conv er te r s

Motors frame sizes 90 upwards in standard design are suitable for operation on static
frequency converters, taking into account the following remarks:
Maximum converter output voltage 500V at peak voltages 1460V and du/dt 13 kV/
us. For higher converter output voltages or stresses, a special insulation is required.
With square characteristic of the load torque, motors can be driven with their rated
torque.
For constant torque, the rated torque of motors with internal cooling must be reduced
due to reduced cooling air inlet. Depending on the control range, the use of an external fan
would be advisable.
The motors frame sizes 90 112 are suitable for a maximum output frequency of the
converter of 60 Hz (e.g. applications with square torque, control range 1:10, such as pumps
and fans). For higher frequencies, a special range with type designation AMI is available on
request. From frame size 132 upwards, motors designed /Y 230/400 V, 50 Hz can be
operated in delta with a maximum frequency of 87 Hz (observe mechanical limit speed).
The motors frame size 56 80 can be operated on single-phase converters up to maximum
60 Hz. (Special range with type designation AMI for operation on three-phase converters
with output voltage 400 V and output frequency > 60 Hz).
The electrical values and dimensions of the range AMI in frame size 56 to 112 are identical
to AM motors (see data tables pages 41-43).

no field weakening

with field weakening

MU/MN

Torque caracteristics of
three-phase motors driven
by frequency converters.

2
3

External cooling

Internal cooling motors 2p = 2

Internal cooling motors 2p = 4-8

f [Hz]

Noise
Depending on the operating point and converter type, converter-fed motors produce
between approx. 4 - 10 dB(A) higher noise values than when supplied from the mains. For
motors driven with a frequency over 50 Hz, more fan noise is produced. We recommend
the use of an external fan.

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

SPARE PAR TS

Part description














1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Shaft protection
Dust seal drive end
Endshield drive end
Bearing drive end
Stator frame
Terminal board
Fixing screw terminal board
Gasket terminal box
Terminal box
Fixing screw terminal box
Terminal box lid
Fixing screw terminal box lid
Gasket terminal box lid
Blank gland plug
Blank gland plug

16
17
18
19
20
21
22
23
24
25
26
27
28
29

Key
Rotor complete
Bearing non-drive end
Pre-load washer
Endshield non-drive end
Fan cover
Fixing screw fan cover
Fan
Fixing bolt endshield non-drive end
Fixing bolt endshield drive end
Fixing bolt motor feet
Motor feet
Fixing washer motor feet
Fixing nut motor feet

Only motors 71-160 frame size have removable feet for easy change of terminal box
position
In enquires and orders for spare parts please state always: designation of spare part, motor
type, mounting arrangement, motor serial number (Product No. when available).
Enquires and orders cannot be handled without these data.

[38]

[39]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

T YPE DE S IGNATION

Apart from other information, it is necessary to specify the exact type designation in all
enquiries, when ordering spare parts or replacement motors or when asking for documentary
information.
The type designation of our motors comprises 8 points of reference, each of which may
consist of several letters and/or numerals. The meaning of each symbol can be seen from
the following table. For motors not included in our standard range, special symbols may be
used which are not listed here.
Meaning of the symbols
Ref. Meaning
Description of symbols used for our motors
point
1

Asynchronous motor

2
Cooling

M
G
MFV

Surface cooled with external fan, cooling fins


Surface cooled without external fan, cooling fins
Surface cooled with forced ventilation, cooling fins

3
Type of motor





blank
H
HE
PH
PE
V
I

Three-phase motor, standard efficiency IE1 code


Three-phase motor, efficiency to EPACT regulations
Three-phase motor, high efficiency IE2 code
Three-phase motor, premium efficiency EISA regulations
Three-phase motor, premium efficiency IE3 code
Three-phase pole-changing motor for driving fans
Special design for three-phase motor driven with frequency converter

Type of motor

Shaft centre height 56, 63, 71, 80, 90, 100, 112, 132,160, 180, 200, 225, 250, 280, 315

5
Frame length


Z
S
M
L

6
Mechanical

design and

output value

A
B
...
Z

7
Frame material


8
Number of poles


A
G
2 4 6 8 -

Mechanical dimension (short)


Mechanical dimension (medium)
Mechanical dimension (long)

Aluminium frame
Cast iron frame

4/2
8/4
4/6
6/8

Example

Three-Phase Motors - Technical Catalogue 1031/11

Three-phase motors designed


for range of rated voltage
380-420 V 5% - 50 Hz

IE1

Standard efficiency motors, IE1 code


Efficiency testing method IEC 60034-2-1;2007
kW

HP

Temperature rise to class B

MN
min-1 Nm
50%

IE1

cos
75% 100%

IN
IA/IN MA/MN MS/MN MK/MN

400V 380-420V 10-3 kgm2

2810
2800

0.3
0.4

49.0
51.0

53.0
56.0

59.0
62.0

0.67
0.68

0.35
0.40

0.40
0.45

3.9
3.5

3.8
3.4

3.8
3.4

3.9
3.5

0.09
0.1

3.4
3.5


Type

[ T]

For mains voltage


to IEC 60038
400 V 10% - 50 Hz

kg

3000 min-1 (2 poles)


AM 56Z AA
AM 56Z BA

2
2

0.09
0.12

0.12
0.16

AM 63Z AA
AM 63Z BA
AM 63Z CA

2 0.18 0.25
2 0.25 0.33
2* 0.37 1) 0.50 1)

2790
2790
2800

0.6
0.9
1.3

54
57
54

58
62
58

63.0
66.0
65.0

0.73
0.70
0.70

0.60
0.80
1.20

0.65
0.75
1.25

3.7
4.5
4.6

3.0
3.2
3.4

3.0
3.2
3.3

3.1
3.3
3.4

0.14
0.17
0.20

3.6
4.1
4.4

AM 71Z AA
AM 71Z BA
AM 71Z CA

2 0.37 0.50
2 0.55 0.75
2* 0.75 1) 1.0 1)

2820
2830
2800

1.3
1.9
2.6

58.0
57.0
58.9

64.0
64.0
65.7

70.0
71.0
72.6

0.78
0.77
0.76

1.0
1.5
2.0

1.2
1.6
2.1

4.7
4.8
5.2

3.6
3.2
3.1

3.4
3.1
3.2

3.6
3.3
3.1

0.36
0.42
0.61

5.8
6.2
7.2

AM 80Z AA
AM 80Z BA
AM 80Z CA

2 0.75
1
2
1.1
1.5
2* 1.5 1) 2 1)

2840
2810
2825

2.5
3.7
5.1

66.3
72.1
74.7

71.5
75.0
77.5

73.0
75.3
77.8

0.78
0.82
0.83

1.9
2.5
3.3

2.0
2.6
3.4

5.0
4.6
5.0

2.8
2.4
2.9

2.8
2.8
3.0

2.9
2.9
3.3

0.75
0.89
1.05

8.4
9.5
11.1

2
2*
2
2*

1.5
1.8
2.2
3 1)

2830
2805
2860
2860

5.1
6.1
7.3
10.0

75.6
74.9
81.5
78.7

78.7
78.0
82.8
81.8

78.6
78.2
81.8
82.2

0.82
0.80
0.81
0.80

3.4
4.2
4.9
6.6

3.5
4.3
4.9
6.8

5.0
4.5
7.1
7.2

3.1
2.6
4.1
3.9

2.9
2.4
3.6
3.4

3.0
2.5
4.0
3.8

1.37
1.37
1.8
2.09

12.7
12.7
16.0
18.7

AM 100L AA
AM 100L BA
AM 100L CA

2
2*
2*

3
4
4 1) 5.5 1)
5.5 1) 7.5 1)

2860
2835
2865

10.0
13.5
18.3

78.9
81.1
83.7

81.4
82.5
84.6

81.5
81.7
83.3

0.85
0.88
0.86

6.4
8.0
11.1

6.7
8.1
11.3

6.0
6.2
7.2

3.1
2.9
3.5

3.1
2.5
3.4

3.3
2.9
4.1

2.80
3.35
4.5

19.3
19.7
25.9

AM 112M AA
AM 112M BA
AM 112M CA

2
2*
2*

4
5.5
7.5

2880
2900
2900

13.3
18.1
24.7

81.9
83.6
86.7

84.0
84.7
87.8

83.5
85.0
87.1

0.82
0.86
0.87

8.4
10.9
14.3

8.7
11.2
14.8

8.0
7.8
8.7

3.4
3.5
4.0

3.5
3.4
3.9

3.6
3.6
4.0

5.20
6.48
8.58

24.3
27.4
33.6

5.5
7.5
7.5
10
9.2 12.5
11
15
15 1) 20 1)

2890
2880
2900
2880
2920

18.2
24.9
30.3
36.5
49.1

83.2
85.6
84.7
87.1
86.4

84.7
86.7
86.8
88.1
88.6

85.0
86.1
87.0
88.0
88.9

0.83
0.87
0.84
0.85
0.83

11.3
14.5
18.4
21.3
29.5

11.4
14.9
18.8
21.7
30.5

6.0
6.4
7.0
6.9
7.0

2.2
2.9
2.8
3.2
3.2

2.1
2.7
2.4
2.8
2.8

2.3
3.1
3.2
3.8
3.7

10.63
13.83
15.0
17.13
20.30

37.0
42.6
48.0
52.5
59.0

2940
2940
2950
2940

35.7
48.7
59.9
71.5

83.4
87.3
88.2
88.7

86.4
88.9
89.7
90.5

87.7
88.9
89.6
90.4

0.83
0.85
0.87
0.90

21.9
28.6
34.3
39.1

22.7
29.2
34.8
39.4

7.4
8.1
8.5
8.4

2.5
3.1
3.6
3.0

2.3
2.6
3.0
2.6

3.1
3.7
4.2
3.7

40.00
51.75
64.00
64.00

77.0
94.0
107.8
108.7

AM
AM
AM
AM

90S AA
90S BA
90L CA
90L DA

AM
AM
AM
AM
AM

132S YA
132S ZA
132M ZA
132M RA
132M TA

2
2
2*
2*
2*

AM
AM
AM
AM

160M VA
160M XA
160L XA
160L RA

2
11
2
15
2 18.5
2* 22

2
2.5
3
4 1)

5.5
7.5
10

15
20
25
30

1) Temperature rise to class F


* Higher output (progressive motor)
IE code not applicable to motors 2, 4, 6 poles with PN < 0.75 kW. Efficiency testing method: IEC 60034-2;1996
High efficiency motors - IE2 code from 180 to 315 frame size

[40]

[41]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

IE1

Three-phase motors designed


for range of rated voltage
380-420 V 5% - 50 Hz

For mains voltage


to IEC 60038
400 V 10% - 50 Hz

Standard efficiency motors, IE1 code


Efficiency testing method IEC 60034-2-1;2007
MN
min-1 Nm
50%

IE1

cos
75% 100%

IN
IA/IN MA/MN MS/MN MK/MN

400V 380-420V 10-3 kgm2 kg


Type

kW

HP

Temperature rise to class B

1500 min-1 (4 poles)


AM 56Z AA
AM 56Z BA

4
4

0.06
0.09

0.08
0.12

1300
1330

0.4
0.6

42.0
43.0

44.0
47.0

48.0
51.0

0.70
0.74

0.28
0.35

0.32
0.40

2.6
2.5

2.1
2.2

2.0
2.1

2.1
2.2

0.14
0.16

2.7
2.9

AM 63Z AA
AM 63Z BA
AM 63Z CA

4 0.12
4 0.18
4* 0.25

0.16
0.25
0.33

1350
1330
1360

0.8
1.3
1.8

46.0
47.0
49.0

50.0
50.0
52.5

57.0
58.0
58.0

0.65
0.70
0.74

0.50
0.65
0.85

0.55
0.70
0.90

2.4
2.3
2.7

2.0
1.9
2.2

1.9
1.8
2.0

2.0
1.9
2.1

0.25
0.27
0.30

3.3
4.1
4.2

AM 71Z AA
AM 71Z BA
AM 71Z CA

4 0.25 0.33
4 0.37 0.50
4* 0.55 1) 0.75 1)

1340
1370
1380

1.8
2.6
3.8

55.0
60.0
61.0

59.0
63.0
64.0

64.0
67.0
69.0

0.66
0.67
0.68

0.90
1.20
1.70

1.00
1.25
1.80

3.2
3.3
3.6

1.9
2.2
2.4

1.8
2.1
2.3

2.0
2.2
2.4

0.70
0.82
0.95

5.7
6.0
7.3

AM 80Z AA
AM 80Z BA
AM 80Z CA

4 0.55 0.75
4 0.75 1.0
4* 1.1 1) 1.5 1)

1400
1410
1385

3.8
5.1
7.6

67.0
68.7
73.4

69.0
70.8
75.7

70.0
72.4
75.2

0.72
0.72
0.77

1.6
2.1
2.8

1.7
2.2
2.9

3.6
4.4
4.4

2.6
2.8
2.5

2.5
2.3
2.5

2.6
2.8
2.6

1.58
2.00
2.41

8.2
9.3
10.6

4
4
4
4*

1.1
1.5
1.8 1)
2.2 1)

1.5
2.0
2.5 1)
3.0 1)

1400
1400
1380
1400

7.5
10.2
12.5
15.0

75.8
77.6
76.3
78.3

76.0
77.8
76.5
78.5

75.4
77.5
75.9
77.9

0.78
0.78
0.81
0.77

2.7
3.6
4.2
5.3

2.9
3.7
4.3
5.5

5.2
5.7
5.5
4.8

2.5
2.8
2.7
2.9

2.4
2.6
2.5
2.8

2.8
3.0
2.9
3.2

2.5
3.13
3.13
4.05

12.5
14.5
14.5
17.0

AM 100L AA
AM 100L BA
AM 100L CA

4
4
4*

2.2
3.0
3.0
4.0
4.0 1) 5.5 1)

1435
1425
1400

14.6
20.1
27.3

76.5
82.0
80.8

79.1
83.0
81.8

79.9
81.6
80.4

0.74
0.78
0.78

5.4
6.8
9.2

5.6
6.9
9.3

5.3
4.6
6.0

2.5
2.4
2.6

2.4
2.3
2.4

2.7
2.5
2.9

4.6
5.58
6.05

19.5
22.5
25.0

AM 112M AA
AM 112M BA

4
4*

4.0
5.5
5.5 1) 7.5 1)

1430
1430

26.7
36.7

83.2
84.1

83.9
84.8

83.1
84.0

0.82
0.83

8.5
11.4

8.8
11.7

6.3
6.5

2.2
2.2

2.0
2.0

2.8
2.9

12.2
15.2

29.5
34.0

1430
1440
1440
1440

36.7
49.7
61.0
72.9

87.2
87.3
86.5
83.5

87.1
87.2
87.5
83.9

86.1
86.2
87.3
84.5

0.82
0.83
0.86
0.87

11.3
15.3
17.7
21.5

11.7
15.5
17.9
22.0

5.8
6.8
8.0
8.3

3.0
3.1
3.5
3.1

2.7
2.7
3.2
3.0

3.0
3.1
3.5
3.3

22.40
29.25
37.25
37.25

41.9
51.0
65.0
65.0

1460
1460
1460
1460

71.9
98.1
121.8
143.9

88.5
89.4
89.9
90.4

89.3
90.2
90.7
91.2

88.7
89.6
90.1
90.6

0.80
0.84
0.84
0.86

22.4
28.8
35.4
41.0

22.7
29.6
36
42

7.5
7.0
7.6
7.8

2.5
2.5
2.5
2.4

2.2
2.2
2.2
2.2

3.1
3.3
3.3
3.2

81.25
105.7
120.4
134.7

88.5
106.5
117.3
128.1

AM
AM
AM
AM

90S AA
90L BA
90L CA
90L DA

AM
AM
AM
AM

132S ZA
132M ZA
132M RA
132M TA

4
5.5
4
7.5
4
9.2
4* 11.0 1)

AM
AM
AM
AM

160M XA
160L XA
160L ZA
160L RA

4
11
4
15
4* 18.5
4* 22

7.5
10.0
12.5
15.0 1)
15
20
25
30

1) Temperature rise to class F


* Higher output (progressive motor)
IE code not applicable to motors 2, 4, 6 poles with PN < 0.75 kW. Efficiency testing method: IEC 60034-2;1996
High efficiency motors - IE2 code from 180 to 315 frame size

Three-Phase Motors - Technical Catalogue 1031/11

Three-phase motors designed


for range of rated voltage
380-420 V 5% - 50 Hz

IE1

Standard efficiency motors, IE1 code


Efficiency testing method IEC 60034-2-1;2007
kW

HP

Temperature rise to class B

MN
min-1 Nm
50%

IE1

cos
75% 100%

IN
IA/IN MA/MN MS/MN MK/MN

400V 380-420V 10-3 kgm2 kg


Type

[ T]

For mains voltage


to IEC 60038
400 V 10% - 50 Hz

1000 min-1 (6 poles)


AM 71Z AA
AM 71Z BA

6
6

0.18 0.25
0.25 1) 0.33 1)

880
880

2.0
2.7

46.0
46.0

48.0
50.0

53.0
54.0

0.60
0.62

0.85
1.10

0.9
1.2

2.2
2.5

1.6
1.7

1.5
1.6

1.6
1.7

0.60
0.90

6.1
6.6

AM 80Z AA
AM 80Z BA

6
6

0.37
0.55

0.5
0.75

920
920

3.8
5.7

47.0
60.0

58.0
64.0

60.0
68.0

0.70
0.67

1.25
1.75

1.3
1.8

2.7
2.9

1.6
2.2

1.6
2.1

2.1
2.1

1.97
2.47

8.0
9.4

AM 90S AA
AM 90L BA

6
6

0.75
1.1

1.0
1.5

910
920

7.9
11.4

70.5
72.0

72.5
73.5

71.5
73.0

0.63
0.66

2.4
3.3

2.5
3.4

2.9
3.0

1.7
1.7

1.5
1.5

1.7
1.7

3.18
4.78

11.6
15.0

AM 100L AA
AM 100L BA

6
6

1.5
1.8

2.0
2.5

930
940

15.4
18.3

73.3
74.6

75.8
77.1

75.3
76.6

0.69
0.67

4.2
5.1

4.4
5.3

3.7
4.2

1.8
2.4

1.8
2.4

2.3
2.8

6.73
9.43

17.5
22.0

AM 112M AA
AM 112M CA

6
6*

2.2
3

3.0
4.0

940
940

22.4
30.5

77.0
81.8

79.0
82.8

78.0
82.8

0.74
0.74

5.3
7.0

5.4
7.2

4.4
5.3

2.4
2.9

2.4
2.9

2.6
2.9

14.18
18.70

26.0
39.0

6
6
6
6*

3
4
5.5
7.5 1)

4.0
5.5
7.5
10 1)

950
950
950
960

30.2
40.2
55.3
74.6

79.5
81.4
82.2
82.8

81.5
83.1
83.6
83.5

81.3
82.7
83.6
82.9

0.72
0.71
0.71
0.75

7.4
9.9
13.5
17.4

7.5
10.5
13.5
17.6

4.9
4.5
4.1
5.0

2.0
2.2
2.2
2.3

1.8
2.0
1.9
1.9

2.4
2.5
2.2
2.8

23.53
29.50
37.75
54.10

36.7
42.5
55.5
64.1

6
6

7.5
11

10
15

970
960

73.8
109.4

84.4
88.1

86.5
88.5

86.3
87.8

0.78
0.78

16.0
23.4

16.3
24.0

6.2
6.0

2.8
2.5

2.7
2.2

3.2
3.5

103
137

96.6
113.6

AM
AM
AM
AM

132S ZA
132M YA
132M ZA
132M TA

AM 160M ZA
AM 160L ZA

1) Temperature rise to class F


* Higher output (progressive motor)
IE code not applicable to motors 2, 4, 6 poles with PN < 0.75 kW. Efficiency testing method: IEC 60034-2;1996
High efficiency motors - IE2 code from 180 to 315 frame size

Efficiency testing method IEC 60034-2;1996


MN
min-1 Nm
50%



cos
75% 100%

IN
IA/IN MA/MN MS/MN MK/MN

400V 380-420V 10-3 kgm2 kg


Type

kW

HP

750 min-1 (8 poles)


AM 71Z AA

0.12

0.16

670

1.7

40

44

50

0.55

0.65

0.7

2.4

2.5

2.4

2.5

0.82

6.0

AM 80Z AA

0.25

0.33

680

3.5

40

47

51

0.62

1.1

1.2

2.2

1.8

1.9

2.0

1.97

8.0

AM 90S AA
AM 90L BA

8
8

0.37
0.55

0.5
0.75

680
680

5.2
7.7

52
52

58
58

59
59

0.53
0.54

1.7
2.5

1.8
2.7

2.1
2.1

1.4
1.4

1.3
1.3

1.6
1.6

3.18
4.78

11.4
15.0

AM 100L AA
AM 100L BA

8
8

0.75
1.1

1.0
1.5

690
690

10.4
15.2

59
59

64
67

65
68

0.65
0.62

2.6
3.9

2.8
4.0

3.0
3.0

1.6
1.9

1.5
1.3

1.7
1.6

6.72
15.93

17.6
22.6

AM 112M AA

1.5

2.0

696

20.6

66

69

70

0.66

4.6

4.8

4.0

1.8

2.0

2.4

16.70

35.0

AM 132S ZA
AM 132M ZA

8
8

2.2
3.0

3.0
4.0

710
710

29.6
40.4

79.3
81.3

80.5
82.0

78.8
79.8

0.64
0.67

6.4
8.1

6.6
8.4

3.4
3.6

1.7
1.7

1.6
1.6

1.7
1.9

29.50
37.75

45.5
54.5

AM 160M YA
AM 160M ZA
AM 160L ZA

8
8
8

4.0
5.5
7.5

5.5
7.5
10.0

700
720
710

54.6
72.9
100.9

84.9
85.6
86.3

84.5
85.2
85.8

84.4
85.0
85.5

0.72
0.73
0.74

9.5
12.8
17.1

9.7
13.3
17.8

4.5
4.0
4.0

1.8
1.8
1.8

1.6
1.6
1.6

2.2
2.3
2.3

75
103
137

75.0
92.0
113

1) Temperature rise to class F

[42]

[43]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

IE2

High Efficiency
Three-phase motors
according to IEC 60034-30;2008

High Efficiency motors, IE2 code


Efficiency testing method IEC 60034-2-1;2007

Type

kW

HP

min-1

MN
Nm 50%

For mains voltage


400 V - 50 Hz

Temperature rise to class B


IE2
75%

cos
100%

IN
IA/IN MA/MN MS/MN MK/MN

400V 10-3 kgm2 kg

3000 min-1 (2 poles)


AMHE 71Z AA

2*

0.75

2865

2.5

75.0

78.1

79.4

0.71

1.9

5.2

3.1

3.0

3.1

0.69

8.2

AMHE 80Z AA
AMHE 80Z BA
AMHE 80Z CA

2
2
2*

0.75
1.1
1.5

1
1.5
2

2900
2880
2880

2.5
3.6
5.0

77.3
79.5
80.5

78.5
81.2
82.1

80.5
81.5
82.4

0.78
0.78
0.78

1.7
2.5
3.4

7.0
6.8
7.0

3.6
3.6
3.5

3.4
3.4
3.4

3.6
3.6
3.6

0.7
0.89
1.1

9.5
11.1
13.5

AMHE 90S AA
AMHE 90L CA

2
2

1.5
2.2

2
3

2880
2860

5.0
7.3

81.0
82.5

82.8
84.0

82.8
84.0

0.80
0.85

3.2
4.4

8.1
8.5

3.6
3.5

3.1
3.2

4.0
3.7

1.56
1.8

14.0
16.0

AMHE 100L AA
AMHE 100L BA

2
2*

3
4

4
5.5

2920
2920

9.8
13.1

84.1
85.2

85.8
86.4

85.5
86.1

0.84
0.86

5.9
7.8

8.0
8.2

3.5
3.3

3.0
3.0

4.0
3.8

4.05
4.1

22.8
22.8

AMHE 112M AA 2
AMHE 112M BA 2*
AMHE 112M CA 2*

4
5.5
7.5

5.5
7.5
10

2940
2920
2900

13.0
18.0
24.7

85.5
85.8
86.5

87.0
87.4
88.3

86.8
87.3
88.3

0.88
0.88
0.87

7.6
10.4
14.2

8.0
8.0
8.1

2.9
3.0
3.0

2.1
2.1
2.2

3.3
3.2
3.4

6.48
8.58
10.50

27.4
34.0
36.0

AMHE 132S YA
AMHE 132S ZA
AMHE 132M ZA
AMHE 132M RA
AMHE 132M TA

2
2
2
2*
2*

5.5
7.5
9.2
11
15

7.5
10
12.5
15
20

2900
2900
2920
2920
2920

18.1
24.7
30.1
36.0
49.1

86.0
86.3
88.4
88.1
88.9

88.0
88.6
89.9
90.0
90.6

87.9
88.4
90.0
89.7
90.3

0.89
0.89
0.87
0.90
0.89

10.2
13.8
16.9
19.8
27.0

7.3
7.5
8.8
7.5
7.5

2.7
2.8
3.2
2.8
3.0

2.3
2.5
3.0
2.6
2.8

3.2
3.3
3.8
3.4
3.5

14.0
16.0
17.5
17.5
21.0

46.0
53.0
58.0
58.0
61.0

AMHE 160M YA
AMHE 160M ZA
AMHE 160L ZA
AMHE 160L TA

2
2
2
2*

11
15
18.5
22

15
20
25
30

2930
2930
2935
2935

35.9
48.9
60.2
71.6

88.9
90.0
90.3
91.0

90.2
91.0
91.6
91.7

90.0
90.8
91.2
91.5

0.87
0.88
0.88
0.90

20.4
27.2
33.3
38.6

7.3
7.6
7.9
8.3

2.4
2.5
2.8
3.0

2.2
2.3
2.4
2.6

3.1
3.1
3.4
3.7

51.75 77.0
55.4 87.1
59.7 97.5
64.0 108.7

AMHE 180M ZG 2

22

30

2930

71.7

90.9

91.8

91.4

0.89

39.04

7.5

2.3

2.0

2.8

98

163

AMHE 200L PG
AMHE 200L RG

2
2

30
37

40
50

2930
2930

97.8
120.6

91.3
91.6

92.3
92.9

92.4
92.8

0.88
0.90

53.3
64.0

6.7
6.3

2.4
2.3

2.0
2.0

2.7
2.7

178
204

228
242

AMHE 225M PG 2

45

60

2940

146.2

92.8

93.3

93.2

0.89

78.3

6.9

2.3

2.0

2.8

285

308

AMHE 250M PG 2

55

75

2950

178.0

92.9

93.8

93.7

0.90

94.1

8.0

2.3

1.9

2.7

411

405

AMHE 280S G
AMHE 280M G

2
2

75
90

100
125

2960
2960

242.0
290.4

93.2
93.6

94.5
94.3

94.1
94.4

0.90
0.91

127.8
151.2

8.0
7.7

2.2
2.2

1.9
1.9

2.7
2.6

791
907

542
596

2
2
2
2

110
132
160
200

150
180
220
270

2970
2970
2970
2975

353.7
424.4
514.5
642.0

93.7
93.6
94.1
94.1

94.6
94.9
95.2
95.3

94.8
95.3
95.3
95.4

0.90
0.90
0.91
0.90

186.0
222.1
266.3
336.2

7.7
7.6
7.8
7.9

2.0
2.0
2.0
2.0

1.8
1.8
1.8
1.8

2.3
2.3
2.3
2.3

1702
1908
2117
2438

922
1010
1085
1220

AMHE 315S G
AMHE 315M G
AMHE 315M RG
AMHE 315L G

* Higher output (progressive motor)

Three-Phase Motors - Technical Catalogue 1031/11

High Efficiency
Three-phase motors
according to IEC 60034-30;2008

IE2

High efficiency motors, IE2 code


Efficiency testing method IEC 60034-2-1;2007

Type

kW

HP

min-1

MN
Nm 50%

[ T]

For mains voltage


400 V - 50 Hz

Temperature rise to class B


IE2
75%

cos
100%

IN
IA/IN MA/MN MS/MN MK/MN

400V 10-3 kgm2 kg

1500 min-1 (4 poles)


AMHE 80Z AA

0.75

1430

79.2

80.3

80.2

0.76

1.8

5.5

2.8

2.7

2.5

11.0

AMHE 90S AA
AMHE 90L BA

4
4

1.1
1.5

1.5
2

1430
1430

7.3
10

81.4
82.0

82.7
83.5

82.5
83.0

0.77
0.77

2.5
3.4

6.1
6.4

4.0
3.9

3.9
3.8

4.1
4.0

3.73
3.73

16.4
16.4

AMHE 100L AA 4
AMHE 100L BA 4

2.2
3

3
4

1450
1440

14.5
19.9

84.0
85.3

85.3
86.6

85.1
86.4

0.74
0.77

5.1
6.5

6.0
6.3

3.2
3.4

3.0
3.1

3.4
3.6

5.58
7.3

22.4
26.5

AMHE 112M AA 4

5.5

1450

26.3

86.0

87.3

87.1

0.78

8.5

6.1

3.1

2.8

3.3

13.3

30.4

AMHE 132S RA 4
AMHE 132M TA 4

5.5
7.5

7.5
10

1450
1450

36.2
49.4

87.5
88.5

88.3
89.4

88.1
89.2

0.84
0.85

10.8
14.4

7.4
7.4

3.0
3.0

2.4
2.4

3.3
3.3

30.0
36.0

55.0
65.0

AMHE 160M ZA 4
AMHE 160L ZA 4

11
15

15
20

1460
1460

71.9
98.1

89.4
90.6

90.3
91.2

90.1
91.0

0.82
0.84

22.0
29.0

6.9
7.4

2.3
2.5

2.1
2.2

2.9
3.1

105.0
120.7

108.0
114.0

156
175

160
175

281

238

487
575

305
310

728

412

1741
2037

560
665

4026
4387
4968
6488

910
1120
1185
1340

AMHE 180M ZG 4
18.5
25
1455
121.4
90.9
91.6
91.4
0.85
34.4
7.8
2.4
2.1
3.0
AMHE 180L ZG 4
22
30
1460
143.9
91.1
92.0
91.6
0.84
41.3
7.5
2.3
2.0
3.0

AMHE 200L RG 4
30
40
1460
196.2
90.2
92.8
92.5
0.88
53.2
7.9
2.4
2.0
2.7

AMHE 225S PG 4
37
50
1470
240.4
92.3
92.9
92.8
0.83
69.3
6.7
2.4
2.0
2.7
AMHE 225M PG 4
45
60
1480
290.4
92.5
93.2
93.3
0.83
83.9
7.0
2.3
2.0
2.8

AMHE 250M PG 4
55
75
1480
354.9
93.1
94.0
93.8
0.87
97.3
7.4
2.4
1.9
2.7

AMHE 280S G
4
75
100
1480
483.9
93.2
94.5
94.4
0.90
127.4
7.5
2.2
1.9
2.6
AMHE 280M G 4
90
125
1480
580.7
93.4
94.8
94.7
0.90
152.4
7.7
2.2
1.9
2.6

AMHE 315S G
4
110
150
1480
709.8
93.9
95.0
94.9
0.89
188.0
7.8
2.0
1.8
2.3
AMHE 315M G 4
132
180
1480
851.8
94.0
95.2
95.1
0.90
222.6
7.8
2.0
1.8
2.3
AMHE 315M RG 4
160
220
1480 1032.4
94.2
95.3
95.3
0.90
269.3
7.9
2.0
1.8
2.3
AMHE 315LG
4
200
270
1480 1290.5
94.3
95.4
95.4
0.90
336.2
7.7
2.0
1.8
2.3

[44]

[45]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

High Efficiency
Three-phase motors
according to IEC 60034-30;2008

High efficiency motors, IE2 code


Efficiency testing method IEC 60034-2-1;2007

Type

kW

HP

min-1

MN
Nm 50%

IE2

For mains voltage


400 V - 50 Hz

Temperature rise to class B


IE2
75%

cos
100%

IN
IA/IN MA/MN MS/MN MK/MN

400V 10-3 kgm2 kg

1000 min-1 (6 poles)


AMHE 90S AA 6
0.75
1
925
7.7
75.3
75.8
76.2
0.65
2.2
4.6
1.7
1.6
1.8
AMHE 90L BA
6
1.1
1.5
935
11.2
78.5
78.7
78.9
0.67
3.0
4.2
1.8
1.8
2.3

AMHE 100L AA 6
1.1
1.5
950
11.1
75.7
77.6
79.5
0.67
3.0
5.5
1.9
1.9
2.4
AMHE 100L BA 6
1.5
2
950
15.1
78.5
79.4
79.8
0.77
3.5
6.7
2.4
2.4
2.8

AMHE 112M AA 6
2.2
3
960
21.9
79.4
81.0
81.8
0.73
5.3
10.4
2.7
1.5
3.7

AMHE 132S YA 6
3
4
960
29.8
82.3
82.9
83.5
0.58
8.9
9.5
2.2
1.4
3.2
AMHE 132M YA 6
4
5.5
955
40.0
84.1
84.8
85.2
0.66
10.3
8.9
2.1
1.2
2.9
AMHE 132M TA 6
5.5
7.5
970
54.1
85.0
86.2
86.5
0.75
12.2
8.4
1.9
1.1
2.7

AMHE 160M YA 6
5.5
7.5
975
53.9
84.7
85.6
86.1
0.71
13.0
9.2
3.3
3.1
4.2
AMHE 160M ZA 6
7.5
10
970
73.8
85.8
87.3
87.5
0.78
15.8
7.7
3.0
2.8
3.8
AMHE 160L ZA 6
9.2
12.4
965
91.0
86.3
87.4
87.8
0.83
18.1
8.3
3.1
2.7
4.1
AMHE 160L TA 6
11
15
965
108.9
87.9
88.2
88.7
0.79
22.5
9.1
3.1
2.9
3.9
AMHE 180LZG 6
15
20
965
148.45
88.5
90.3
90.1
0.83
29.0
7.0
2.3
2.1
2.9

AMHE 200LPG 6
18.5
25
965
183.09
88.9
90.8
90.6
0.84
35.1
7.0
2.4
2.1
3.2
AMHE 200LRG 6
22
30
970
216.6
89.3
91.4
91.2
0.85
41.0
7.0
2.3
1.9
3.1

AMHE 225MPG 6
30
40
975
293.85
89.6
91.7
91.9
0.86
54.8
7.0
2.2
1.9
2.7

AMHE 250MPG 6
37
50
975
362.41
90.7
92.4
92.5
0.84
68.7
7.0
2.3
2.1
2.7

AMHE 280SG
6
45
60
980
438.52
91.6
92.9
92.9
0.85
82.3
7.0
2.3
2.0
2.8
AMHE 280MG 6
55
75
980
536.0
92.1
93.4
93.3
0.86
98.9
7.0
2.2
1.9
2.7

AMHE 315SG
6
75
100
985
727.16
93.1
93.8
93.8
0.87
132.7
7.0
2.1
1.9
2.5
AMHE 315MG 6
90
125
985
872.59
93.3
94.1
94.2
0.88
156.7
7.0
2.0
1.8
2.3
AMHE 315MRG 6
110
150
980 1071.94
93.2
94.5
94.6
0.89
188.6
6.7
2.0
1.8
2.3
AMHE 315LG
6
132
160
980 1286.33
93.7
94.7
94.8
0.88
228.4
6.7
2.0
1.8
2.3

Three-Phase Motors - Technical Catalogue 1031/11

4.78
6.45

15.0
20.3

7.48
11.6

19.4
27.1

18.7

39.0

37.7
44.4
54.1

55.8
65.5
64.1

75.2
103
125
156

70.5
96.6
103
129

285

172

405
471

225
275

801

312

992

386

1785
2208

560
593

4632
5525
6896
8023

741
920
1243
1428

IE2

High Efficiency
Three-phase motors
according to EPAct

Insulation class F
Temperature rise to class B
S.F. 1.15

Verified by UL Underwriters Laboratories Inc.


HP

min-1

MN
Nm
50%


75%


cos
100%


Type

kW

[ T]

For mains voltage


460 V - 60 Hz

IN
IA/IN MA/MN MS/MN MK/MN

460V 10-3 kgm2 kg

3600 min-1 (2 poles)


AMH 90S AA
AMH 90L BA

2
2

1.5
2.2

2
3

3470
3500

4.1
6.0

83.8
85.4

84.9
86.6

84.3
86.3

0.88
0.84

2.7
3.9

7.7
7.5

3.1
4.4

3
4

3.6
4.4

1.6
1.8

14
16

AMH 100L AA
AMH 100L BA

2
2

2.2
3

3
4

3530
3525

6.0
8.1

86.5
86.4

87.9
87.8

87.8
87.7

0.84
0.82

3.9
5

11.5
10.5

4.7
5.6

4.1
5.3

5.5
5.8

3.3
4.0

19.7
22.8

AMH 112M AA 2
AMH 112M AA 2
AMH 112M BA 2*

3.7
4
5.5

5
5.5
7.5

3530
3540
3500

10.0
10.8
15.0

86.1
86.1
85.0

88.4
88.3
88.6

88.1
88.0
88.5

0.84
0.87
0.85

6.3
6.6
9.3

14.3
13.7
10.9

5.7
5.3
4.5

2.1
1.9
2.48

5.8
5.4
4.3

8.6
8.6
8.6

33.6
33.6
34

AMH 132S ZA 2
AMH 132S TA 2
AMH 132M TA 2

5.5
7.5
9.2

7.5
10
12.4

3520
3510
3520

14.9
20.4
25.0

86.1
89.7
88.8

88.2
90.1
89.9

88.5
89.5
89.5

0.87
0.91
0.91

9.2
11
14

7.9
8.1
8.1

3.3
3.4
3.3

2.9
2.9
2.9

3.7
3.9
3.9

20.5
20.5
25

53
53
59

AMH 160M YA 2
AMH 160M ZA 2
AMH 160L ZA 2

11
15
18.5

15
20
25

3550
3545
3550

29.6
40.4
49.8

90.1
91.2
91.5

91
89.9
92

91.0
91.0
91.7

0.88
0.88
0.87

17.3
23.5
28.8

8.7
8.7
8.9

2.8
2.8
2.8

2.2
2.2
2.2

3.6
3.6
3.6

51.7
64
64

87.8
104
105

* Higher output (progressive motor)

HP

min-1

MN
Nm
50%


75%


cos
100%


Type

kW

IN
IA/IN MA/MN MS/MN MK/MN

460V 10-3 kgm2 kg

1800 min-1 (4 poles)


AMH 90L AA
AMH 90L BA
AMH 90L CA

4
4
4

1.1
1.5
1.8

1.5
2
2.4

1745
1735
1720

6.0
8.3
10.0

82.2
82.1
82.2

84.2
84.4
84.3

84.2
84.4
84.3

0.76
0.73
0.77

2.1
3.1
3.4

7.2
7.5
7.4

3.8
4
4.4

4
3.9
3.3

4.6
4.2
4

3.7
3.7
3.7

16.4
16.4
16.4

AMH 100L AA
AMH 100L BA

4
4

2.2
3

3
4

1750
1740

12.0
16.5

85.8
85.7

87.6
87.7

87.5
87.6

0.70
0.76

4.6
5.6

6.5
7.4

3.8
3

3.1
2.8

3.9
3.2

5.6
7.3

22.4
26.5

AMH 112M AA 4
AMH 112M AA 4

3.7
4

5
5.5

1750
1745

20.2
21.9

86.3
86.5

87.9
88.1

87.8
88.0

0.79
0.81

6.8
7

6.9
6.7

4.2
3.9

3.5
3.2

4.5
4.2

13.3
13.3

30.4
30.4

AMH 132S ZA 4
AMH 132M ZA 4
AMH 132M TA 4

5.5
7.5
9.2

7.5
10
12.4

1755
1750
1745

29.9
40.9
50.3

88.8
89.5
89.2

89.8
90.2
90

89.5
89.5
89.5

0.84
0.84
0.84

9.4
12.4
16

7.9
8.1
8.3

3.4
3.5
3.6

2.8
2.9
2.9

3.7
3.8
3.9

30
36
36

56
65
65

AMH 160M ZA
AMH 160L ZA

11
15

15
20

1770
1770

59.3
80.9

90.8
91.4

91.4
91.6

91.0
91.0

0.84
0.84

18.5
24

8.6
8.2

3.2
3.2

2.3
2.3

3.4
3.4

105.7
120.7

108
114

4
4

[46]

[47]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

Premium Efficiency
Three-phase motors
according to IEC 60034-30;2008

Premium efficiency motors, IE3 code


Efficiency testing method IEC 60034-2-1;2007

Type

kW

3000 min-1 (2 poles)

HP

min-1

MN
Nm 50%

IE3

For mains voltage


400 V - 50 Hz

Temperature rise to class B


IE2
75%

cos
100%

IN
IA/IN MA/MN MS/MN MK/MN

400V 10-3 kgm2 kg


AMPE 90S AA
2
1.5
2
2910
4.9
80.1
83.8
85.0
0.72
3.5
9.1
3.9
4.3
4.6
AMPE 90L BA
2
2.2
3
2865
7.3
84.8
85.6
86.0
0.86
4.3
7.9
4.5
4.2
4.7

AMPE 100L AA 2
3
4
2900
9.9
84.6
86.8
87.1
0.85
5.8
10.9
5.5
3.5
4.5

AMPE 112M AA 2
3.7
5
2950
12.0
86.3
88.9
89.9
0.83
7.1
12.8
5.2
2.3
3.8
AMPE 112M BA 2
4
5.5
2945
13.0
86.9
88.4
90.1
0.85
7.5
12.6
4.7
2.3
3.8
AMPE 112M CA 2
5.5
7.5
2935
17.9
85.6
88.3
89.2
0.78
11.3
11.7
4.7
2.7
4

AMPE 132S ZA 2
5.5
7.5
2920
18.0
88.2
89.7
89.8
0.88
10.0
7.7
3.2
2.9
3.6
AMPE 132S TA 2
7.5
10
2930
24.4
89.4
91.0
91.1
0.88
13.5
7.7
3.6
3.3
4.2
AMPE 132M TA 2
9.2
12.4 2935
29.9
89.4
91.0
91.2
0.85
17.0
9.7
4.2
3.9
5.1
AMPE 132M RA 2
11
15
2935
35.8
89.2
90.8
91.2
0.81
21.4
9.5
4.2
3.7
4.9

AMPE 160M YA 2
11
15
2935
35.8
88.7
90.5
91.2
0.89
19.5
11.1
3.7
2.7
4.7
AMPE 160M ZA 2
15
20
2945
48.6
89.5
91.4
92.0
0.88
26.7
12.5
4.6
3.3
5.9
AMPE 160L ZA 2
18.5
25
2945
60.0
89.7
91.7
92.4
0.82
35.3
12.8
4.9
3.5
6.3
AMPE 160L TA 2
22
30
2930
71.7
91.6
92.6
92.7
0.85
40.2
10.9
4.1
3.0
5.3

1.6
1.8

14
16

22.8

8.6
8.6
8.6

33.6
33.6
33.6

20.5
22.8
25
25

53
56
59
59

51.7
64
64
64

87.8
104
104
104

For dimensions AMPE 2 poles motors, please see dimensions AMHE motors


Type

kW

HP

min-1

MN
Nm 50%

IE2
75%

cos
100%

IN
IA/IN MA/MN MS/MN MK/MN

400V 10-3 kgm2 kg

1500 min-1 (4 poles)



AMPE 90S AA
4
1.1
1.5
1445
7.3
82.3
85.2
85.8
0.70
2.6
8.5
4.6
4.5
4.9
AMPE 90L BA
4
1.5
2
1420
10.1
84.7
85.4
85.7
0.76
3.3
7.8
4.1
4.0
4.3
AMPE 90L CA
4
1.8
2.4
1420
12.1
83.8
84.9
85.3
0.70
4.3
8.0
4.1
4.0
4.3

AMPE 112M AA 4
3.7
5
1450
24.4
87.7
88.6
88.8
0.80
7.5
9.9
3.3
2.7
4.9
AMPE 112M BA 4
4
5.5
1445
26.4
87.9
88.5
88.8
0.82
7.9
9.3
3.1
2.4
4.6

AMPE 132S ZA 4
5.5
7.5
1450
36.2
90.6
91.0
91.2
0.82
10.6
9.4
3.7
3.2
4.3
AMPE 132M ZA 4
7.5
10
1465
48.9
89.8
91.2
91.5
0.68
17.5
9.7
4.4
3.7
5.1
AMPE 132M TA 4
9.2
12.4 1455
60.4
90.6
91.2
91.3
0.74
19.7
9.8
4.9
4.2
5.8

AMPE 160M ZA 4
11
15
1470
71.5
92.2
92.6
92.9
0.79
21.6
10.1
4.6
3.3
4.9
AMPE 160L ZA 4
15
20
1465
97.8
92.1
92.5
92.8
0.78
29.9
10.1
4.4
3.2
4.7

For dimensions AMPE 4 poles motors, please consult us

Three-Phase Motors - Technical Catalogue 1031/11

3.7
3.7
3.7

16.4
16.4
16.4

16.4
16.4

36
36

36
45
57

65
79
98

120.7
135

114
120

IE3

Premium Efficiency
Three-phase motors
according to EISA

For mains voltage


460 V - 60 Hz

Verified by UL Environment

Type

kW

HP

min-1

[ T]

Temperature rise to class B


MN
Nm
50%


75%


cos
100%

IN
IA/IN MA/MN MS/MN MK/MN

460V 10-3 kgm2 kg

3600 min-1 (2 poles)



AMPH 90S AA 2
1.5
2
3515
4.1
81.2
84.7
85.5
0.78
2.8
8.9
3.7
3.6
4.3
AMPH 90L BA 2
2.2
3
3480
6.0
83.6
86.1
86.5
0.84
3.8
7.7
4.4
4.0
4.4

AMPH 100L AA 2
3
4
3515
8.2
85.8
88.1
88.5
0.86
4.9
10.6
5.6
5.3
5.3

AMPH 112M AA 2
3.7
5
3550
10.0
84.0
87.6
88.5
0.86
6.1
12.5
5.1
1.9
5.2
AMPH 112M BA 2
4
5.5
3540
10.8
85.3
88.0
88.5
0.87
6.5
12.3
4.7
1.7
4.8
AMPH 112M CA 2
5.5
7.5
3530
14.9
86.2
89.0
89.5
0.86
8.9
11.4
4.5
2.5
4.3

AMPH 132S ZA 2
5.5
7.5
3540
14.8
87.3
89.6
89.5
0.88
8.8
7.5
3.0
2.6
3.3
AMPH 132S TA 2
7.5
10
3540
20.2
88.0
90.3
90.2
0.87
12.0
7.5
3.4
2.9
3.9
AMPH 132M TA 2
9.2
12.4
3545
24.8
87.7
90.1
90.2
0.88
14.5
9.4
4.0
3.5
4.7
AMPH 132M RA 2
11
15
3535
29.7
87.5
90.4
91.0
0.86
17.7
9.2
4.0
3.5
4.7

AMPH 160M YA 2
11
15
3550
29.6
86.6
90.0
91.0
0.89
17.0
10.8
3.5
2.5
4.5
AMPH 160M ZA 2
15
20
3555
40.3
90.1
92.0
91.0
0.85
24.4
12.2
4.4
3.1
5.6
AMPH 160L ZA 2 18.5
25
3555
49.7
90.0
92.2
91.7
0.82
31.0
12.5
4.6
3.3
6.0
AMPH 160L TA 2
22
30
3540
59.3
90.7
92.5
91.7
0.84
35.8
10.6
3.9
2.8
5.0

1.6
1.8

14.0
16.0

4.0

22.8

8.6
8.6
8.6

33.6
33.6
33.6

20.5
22.8
25.0
25.0

53.0
56.0
59.0
59.0

51.7
64.0
64.0
64.0

87.8
104
104
104

For dimensions AMPH 2 poles motors, please see dimensions AMH motors


Type

kW

HP

min-1

MN
Nm
50%


75%


cos
100%

IN
IA/IN MA/MN MS/MN MK/MN

460V 10-3 kgm2 kg

1800 min-1 (4 poles)


AMPH 90S AA 4
1.1
1.5
1745
6.0
82.8
85.6
86.5
0.71
2.2
8.2
4.4
4.3
4.6
AMPH 90L BA 4
1.5
2
1735
8.2
83.5
86.2
86.5
0.74
2.9
7.5
3.8
3.7
4.0
AMPH 90L CA 4
1.8
2.4
1730
9.9
85.2
86.7
86.5
0.68
3.8
7.8
3.9
3.8
4.1

AMPH 112M AA 4
3.7
5
1765
20.0
87.3
89.3
89.5
0.80
6.5
9.6
3.1
2.5
4.6
AMPH 112M BA 4
4
5.5
1760
21.7
87.7
89.4
89.5
0.81
6.9
9.0
2.9
2.3
4.3

AMPH 132S ZA 4
5.5
7.5
1760
29.9
91.0
92.1
91.7
0.81
9.3
9.1
3.5
3.0
4.1
AMPH 132M ZA 4
7.5
10
1760
40.7
90.8
91.5
91.7
0.79
13.0
9.4
4.1
3.5
4.8
AMPH 132M TA 4
9.2
12.4
1760
49.9
90.9
91.6
91.7
0.73
17.2
9.5
4.7
4.0
5.5

AMPH 160M ZA 4
11
15
1770
59.4
91.5
92.5
92.4
0.80
18.7
9.8
4.4
3.1
4.6
AMPH 160L ZA 4
15
20
1765
81.2
92.4
93.0
93.0
0.77
26.3
9.8
4.2
3.0
4.4

3.7
3.7
3.7

16.4
16.4
16.4

16.4
16.4

36.0
36.0

36.0
45.0
57.0

65.0
79.0
98.0

120.7
135.0

114
120

For dimensions AMPH 4 poles motors, please consult us

[48]

[49]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

For mains voltage


to IEC 60038
400 V 10% - 50 Hz

Three-phase pole-changing motors


designed for range of rated voltage
380-420 V 5% - 50 Hz

Temperature rise to class B



Type

kW

HP

min-1

MN
Nm


cos
100%


IN
IA/IN
MA/MN

400V 380-420V
10-3 kgm2 kg

1500/3000 min-1 (4/2 poles) - Dahlander connection /YY


AM 63Z AA

4/2

0.20/0.30 0.27/0.40

1345/2700

1.4/1.1

56/65

0.65/0.81

0.8/0.83

0.89/0.88

2.4/3.2

2.1/2.1

0.40

4.6

AM 71Z AA

4/2

0.30/0.45 0.40/0.65

1374/2830

2.1/1.5

61/66

0.78/0.73

1.0/1.35

1.2/1.5

3.3/3.0

2.3/2.1

0.76

6.3

AM 80Z AA
AM 80Z BA
AM 80Z CA

4/2
4/2
4/2

0.45/0.60 0.65/0.80
0.55/0.75 0.75/1.0
0.8/1.1
1.1/1.5

1390/2760
1435/2850
1425/2830

3.1/2.1
3.7/2.5
5.4/3.7

64/68.8
70/71.2
76.1/77.2

0.75/0.80
0.67/0.77
0.70/0.79

1.4/1.6
1.7/2.0
2.2/2.6

1.5/1.7
1.8/2.1
2.5/2.8

3.8/4.0
4.5/5.0
4.5/4.9

2.3/2.2
2.6/2.8
2.5/2.7

1.58
2.00
2.41

8.3
11.5
14.7

AM 90L AA
AM 90L BA

4/2
4/2

1.2/1.55
1.6/2.0 1)

1.6/2.1
1435/2850
2.15/2.7 1) 1390/2810

8/5.2
11/6.8

77.4/78.3
73.5/75.5

0.71/0.79
0.78/0.86

3.2/3.7
4.0/4.6

3.4/3.9
4.1/4.7

4.7/5.1
4.1/5.5

2.6/2.7
2.7/2.6

3.10
3.73

15.6
17.1

AM 100L AA 4/2
AM 100L BA 4/2
AM 100L CA 4/2

1.8/2.5
2.2/3.0
2.6/3.3

2.5/3.35
3.0/4.0
3.5/4.4

1420/2865
1410/2830
1430/2890

12.1/8.3
14.9/10.1
17.4/10.9

78.5/77.4
74.6/71.4
82.6/78.6

0.76/0.84
0.72/0.82
0.78/0.76

4.5/5.6
5.9/7.4
5.9/8.0

4.7/5.8
6.1/7.7
6.1/8.5

5.2/5.5
4.2/4.3
4.7/5.5

2.2/2.2
1.8/2.0
1.9/2.2

4.60
4.60
5.58

21.4
22.5
23.2

AM 112M AA 4/2

3.3/4.4

4.4/5.9

1410/2800

22.4/15

77.4/75.4

0.82/0.85

7.5/9.9

7.8/10.6

4.5/5.1

2.1/2.4

13.30

36.1

AM 132S ZA 4/2
AM 132M ZA 4/2

4.4/5.5
6.6/8.1

6.0/7.5
9.0/11.0

1450/2925
1460/2920

29/18
43.2/26.5

83.0/84.6
85.4/84.5

0.70/0.87 11.0/10.8 12.0/11.8 4.4/7.2


0.76/0.90 14.7/15.4 15.5/16.4 5.5/7.5

2.2/2.7 13.83 42.6


2.6/2.9 17.13 51.4

8.8/11.0 12.0/15.0 1460/2940


12.5/15.0 17.0/20.4 1470/2955

57.6/35.7
81.2/48.5

87.1/87.5
89.4/90.0

0.79/0.91 18.5/20.0 19.0/21.0 5.5/7.5


0.74/0.90 27.4/26.8 29.0/28.2 4.8/7.4

2.0/1.9 51.75 94.0


2.1/2.3 64.00 108.7

MN
Nm


cos
100%

AM 160M ZA 4/2
AM 160L ZA 4/2


Type

kW

HP

min-1


IN
IA/IN
MA/MN

400V 380-420V
10-3 kgm2 kg

750/1500 min-1 (8/4 poles) - Dahlander connection /YY


AM 71Z AA

8/4

0.09/0.15 0.12/0.20

610/1310

1.4/1.1

40/56

0.61/0.75

0.53/0.52

0.59/0.57

2.5/3.2

1.6/1.6

0.71

6.3

AM 80Z AA
AM 80Z BA

8/4
8/4

0.18/0.37 0.25/0.50
0.26/0.51 0.35/0.68

700/1370
700/1360

2.5/2.6
3.5/3.6

43.2/58.7
44.1/61.2

0.63/0.83
0.60/0.88

1.0/1.1
1.2/1.4

1.1/1.2
1.3/1.5

2.6/3.4
2.5/3.6

1.8/1.6
2.0/1.6

1.97
2.47

7.9
9.2

AM 90S AA
AM 90L BA

8/4
8/4

0.37/0.75 0.50/1.0
0.5/1.0 0.67/1.34

690/1385
690/1410

5.1/5.2
6.9/6.8

52.2/67.1
52.2/72.5

0.58/0.82
0.58/0.80

1.8/2.0
2.4/2.4

1.9/2.1
2.5/2.5

2.8/3.9
3.3/4.0

1.9/1.8
2.3/1.9

3.18
4.78

13.5
15.7

AM 100L AA 8/4
AM 100L BA 8/4

0.7/1.4 0.94/1.9 700/1440


0.9/1.8 1) 1.2/2.5 1) 690/1415

9.5/9.3
12.5/12.1

57.2/78.5
62/76

0.50/0.78
0.56/0.87

3.5/3.3
3.8/4.0

3.7/3.4
4.0/4.3

2.8/4.3
2.5/4.5

2.1/1.9
1.9/1.8

5.58
6.00

21.9
23.7

AM 112M AA 8/4
AM 112M BA 8/4

1/1.8
1.34/2.5 710/1445
1.3/2.6 1) 1.75/3.0 1) 705/1420

13.5/11.9
17.6/17.5

66.1/78.5
70.0/76.3

0.61/0.82
0.65/0.88

4.1/4.1
4.6/5.7

4.4/4.2
4.8/5.9

3.9/6.3
3.2/4.8

2.2/2.1
2.1/2.0

14.18
16.70

31.7
34.2

AM 132S ZA 8/4
AM 132M ZA 8/4

2.1/3.7
2.6/4.8

2.9/5.0
3.5/6.5

710/1440
715/1450

28.2/24.5
34.7/31.6

70.2/76.1
71.6/78.8

0.66/0.84
0.60/0.80

6.5/8.4
8.8/11.0

6.7/8.6
9.8/12.0

4.0/5.2 1.9/1.7
4.3/5.5 2.3/1.8

29.50
37.75

42.5
55.5

AM 160M YA 8/4
AM 160L YA 8/4
AM 160L ZA 8/4

4.0/6.3 5.5/8.6
4.8/7.5 6.5/10.0
5.9/10.3 8.0/14.0

710/1410
730/1470
725/1450

53.8/42.7
62.8/48.7
77.7/67.8

80.0/81.0
80.0/85.0
81.0/87.0

0.64/0.88
0.65/0.85
0.66/0.88

11.3/12.8 12.3/13.5
13.2/15.0 14.0/16.0
16.1/19.5 17.0/20.4

1) Temperature rise to class F

Three-Phase Motors - Technical Catalogue 1031/11

4.6/6.5 1.8/ 1.7 81.25 88.5


4.5/6.5 1.8/1.6 105.75 106.5
5.0/6.0 1.9/1.6 127.50 110.5

For mains voltage


to IEC 60038
400 V 10% - 50 Hz

Three-phase pole-changing motors


designed for range of rated voltage
380-420 V 5% - 50 Hz

[ T]

Temperature rise to class B



Type

kW

HP

min-1

MN
Nm


cos
100%


IN
IA/IN
MA/MN

400V 380-420V 10-3 kgm2 kg

1500/1000 min-1 (4/6 poles) - separate windings


AM 71Z AA

4/6 0.22/0.15 0.30/0.20

1430/900

1.5/1.6

61/44

0.7/0.64

0.78/0.68

0.83/0.73

1.9/3.4

1.5/1.8

0.73

6.2

AM 80Z AA
AM 80Z BA

4/6 0.37/0.26 0.50/0.35


4/6 0.55/0.37 0.75/0.50

1385/905
1380/900

2.6/2.7
3.8/3.9

61.4/48.1
60.5/51.1

0.82/0.80
0.64/0.82

1.1/1.0
1.5/1.3

1.1/1.1
1.6/1.4

3.7/2.6
3.7/2.7

1.7/1.3
1.6/1.2

1.97
2.47

8.3
10.0

AM 90S AA
AM 90L BA

4/6
4/6

0.75/0.5
1/0.65

1.0/0.67
1.34/0.87

1400/930
1380/920

5.1/5.1
6.9/6.7

63/64
68.8/67.1

0.81/0.61
0.81/0.62

2.2/1.9
2.6/2.3

2.3/2.1
2.8/2.5

3.0/3.5
2.9/3.4

1.4/1.8
1.1/1.6

4.10
4.78

13.4
16.4

AM 100L AA 4/6
AM 100L BA 4/6

1.2/0.8
1.6/1.0

1.6/1.07
2.15/1.34

1460/940
1445/935

7.8/8.1
10.6/10.2

76.0/67.9
77.6/69.5

0.66/0.70
0.73/0.63

3.5/2.5
4.1/3.3

3.8/2.6
4.3/3.5

4.7/3.0
5.8/3.0

2.1/1.5
2.8/1.7

4.60
5.58

24.4
33.2

AM 112M AA 4/6
AM 112M BA 4/6

1.8/1.3
2.6/1.85

2.5/1.75
3.5/2.5

1445/950
1445/950

11.9/13.1
17.2/18.6

74.6/69.5
73.8/71.6

0.85/0.78
0.86/0.73

4.2/3.6
6.0/5.2

4.4/3.7
6.2/5.4

5.9/3.8
6.1/4.4

1.9/1.3
2.0/1.7

14.18
17.53

33.3
37.0

AM 132S ZA 4/6
AM 132M ZA 4/6

3.1/2.2
4.0/2.6

4.2/3.0
5.5/3.5

1440/965
1470/975

20.6/21.8
26/25.5

80/78
81.0/79.3

0.80/0.74
0.83/0.74

7/5.5
8.6/6.4

7.5/6
9.3/7.0

5.8/5.6
7.7/5.2

2.1/2.0
2.0/1.9

22.4 41.9
29.25 51.0

AM 160M YA 4/6
AM 160M ZA 4/6
AM 160L ZA 4/6

5.5/3.7
7.5/4.8
11.0/6.6

7.5/5.0
10.2/6.5
15.0/9.0

1480/970
1465/960
1470/960

35.5/36.4
48.9/47.7
71.5/65.7

84.0/81.4
85.0/82.6
86.0/83.8

0.79/0.73
0.83/0.75
0.86/0.75

7.5/4.5
7.4/4.6
7.2/5.0

2.5/1.6 81.25 88.5


2.4/1.6 81.25 88.5
2.3/1.8 105.75 106.5


Type

kW

HP

min-1

MN
Nm


cos
100%

12.0/9.0 12.9/9.6
15..4/11.2 15.8/11.5
21.6/15.2 22.5/16.0


IN
IA/IN
MA/MN

400V 380-420V
10-3 kgm2 kg

1000/750 min-1 (6/8 poles) - separate windings


AM 80Z AA

6/8

0.37/0.18 0.50/0.25

915/700

3.9/2.5

51.1/44.2

0.81/0.65

1.3/1.0

1.4/1.0

2.8/2.5

1.4/1.7

2.47

9.5

AM 90L AA

6/8

0.55/0.30 0.75/0.40

950/710

5.5/4

65.2/45.1

0.62/0.52

2.0/1.8

2.1/1.9

3.9/2.6

2.5/1.9

4.78

16.2

AM 100L AA 6/8

0.75/0.45

1.0/0.60

960/720

7.5/6

72.6/61.8

0.67/0.54

2.2/2.0

2.3/2.1

4.1/2.9

1.9/1.9

6.73

23.4

AM 112M AA 6/8
AM 112M BA 6/8

0.95/0.65
1.5/0.75

1.3/0.90
2.0/1.0

965/715
970/720

9.4/8.7
14.8/9.9

65.2/62.1
75.3/64.6

0.78/0.70
0.66/0.60

3.0/2.2
4.4/2.8

3.2/2.3
4.6/3.0

4.5/3.8
4.6/3.8

1.4/1.7
2.2/2.1

14.18
18.70

32.0
36.2

AM 132S ZA 6/8
AM 132M ZA 6/8

2.2/1.2
3.0/1.7

3.0/1.6
4.1/2.3

970/730
980/730

21.7/15.7
29.2/22.2

73.5/66.0
78.2/72.5

0.69/0.60
0.72/0.64

6.3/4.4
7.7/5.3

6.6/4.8
8.2/5.9

4.5/3.7
5.4/4.3

1.6/1.7
1.7/1.7

29.5
37.75

42.5
55.5

AM 160M YA 6/8
AM 160M ZA 6/8

4.8/2.6
5.9/3.3

6.5/3.5
8.0/4.5

970/730
970/730

47.3/34
58.1/43.2

83.0/74.0
83.2/73.0

0.80/0.70 10.5/7.3 11.0/7.7 4.8/3.6


0.76/0.60 13.5/10.9 14.5/11.4 6.5/5.0

1.9/1.8 112.7
2.2/2.1 150.25

88.0
97.5

[50]

[51]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

For mains voltage


to IEC 60038
400 V 10% - 50 Hz

Three-phase pole-changing motors designed


for range of rated voltage
380-420 V 5% - 50 Hz

Temperature rise to class B



Type

kW

min-1

HP

MN
Nm


cos
100%


IN
IA/IN
MA/MN

400V 380-420V
10-3 kgm2 kg

1500/3000 min-1 (4/2 poles) - Dahlander connection Y/YY


AMV 63Z AA

4/2

0.07/0.33

0.095/0.45

1350/2700

0.5/1.2

55/60

0.70/0.80

0.25/0.95

0.27/1.1

2.5/2.6

1.8/1.6

0.37

5.0

AMV 71Z AA
AMV 71Z BA

4/2
4/2

0.08/0.37
0.12/0.55

0.11/0.5
0.16/0.75

1350/2870
1430/2835

0.6/1.2
0.8/1.9

60/64
70/68

0.65/0.68
0.65/0.72

0.30/1.3
0.40/1.6

0.35/1.4
0.42/1.7

3.2/4.3
4.1/4.0

2.0/2.8
3/2.8

0.82
1.08

7.9
10.0

AMV 80Z AA
AMV 80Z BA

4/2
4/2

0.15/0.75
0.22/1.1

0.2/1.0
0.3/1.5

1400/2710
1420/2820

1/2.6
1.5/3.7

70/68
70/73

0.68/0.80
0.75/0.84

0.45/1.9
0.6/2.5

0.45/2.0
0.65/2.6

2.6/4.6
4.6/4.7

2.8/2.9
2.7/2.9

1.58
2.0

8.3
11.5

AMV 90L AA
AMV 90L BA

4/2
4/2

0.30/1.5
0.44/2.2

0.4/2.0
0.6/3.0

1400/2830
1430/2830

2/5.1
2.9/7.4

69/70
74/72

0.70/0.84
0.76/0.89

0.9/3.5
1.1/4.8

1.0/3.7
1.2/5.0

4.7/5.0
4.5/5.2

2.7/3.0
2.6/2.8

3.13
3.73

15.6
17.1

AMV 100L AA
AMV 100L BA

4/2
4/2

0.50/2.5
0.60/3.0

0.67/3.3
0.8/4.0

1430/2840
1440/2850

3.3/8.4
4/10.1

72/73
78/77

0.77/0.88
0.79/0.87

1.3/5.3
1.3/6.2

1.4/5.6
1.4/6.5

4.6/5.0
4.5/4.5

2.2/2.3
2.2/2.1

4.6
5.58

21.4
23.2

AMV 112M AA 4/2


AMV 112M BA 4/2

0.75/3.70
0.9/4.5

1.0/5.0
1.2/6.1

1440/2850
1440/2850

5/12.4
6/15.1

74/72
75/73

0.80/0.90
0.82/0.90

1.7/7.9
2.0/9.5

1.9/2.2
2.1/9.8

4.5/5.1
4.5/5.5

2.0/2.4
2.0/2.3

13.3
14.75

36.1
40.0

AMV 132S AA 4/2


AMV 132S BA 4/2
AMV 132M CA 4/2

1.1/5.5
1.5/7 1)
1.9/8.0

1.5/7.5
2/9.5 1)
2.6/10.9

1440/2880
1440/2900
1450/2930

7.3/18.2
9.9/23.1
12.5/26.1

81.5/84.8
82.0/86.0
83.7/88.0

0.78/0.90
0.78/0.92
0.82/0.87

2.5/10.4
3.4/12.8
4.0/15.1

2.6/11.0
3.8/13.0
4.0/16.0

5.0/6.0
5.3/6.5
5.5/7.0

2.1/2.8
2.2/2.9
2.2/3.0

13.83
13.83
17.13

42.6
42.6
51.4

AMV 160M AA 4/2


AMV 160M BA 4/2
AMV 160L CA 4/2

2.8/11
3.3/13.5 1)
4.4/18.5 1)

3.8/15.0
4.5/18.3 1)
6.0/25.1 1)

1440/2940
1440/2920
1450/2940

18.6/35.7
21.9/44.2
29/60.1

82.5/88.2
83.0/88.5
85.5/89.5

0.78/0.90
0.80/0.92
0.83/0.92

6.3/20.0
7.2/24.0
9.0/32.5

7.0/20.4
7.5/24.0
9.5/33.0

5.0/7.5
5.5/7.5
5.5/7.5

2.0/2.1
2.0/2.2
2.0/2.2

51.75
51.75
64.0

94
94
108.7

MN
Nm


cos
100%


Type

kW

HP

min-1


IN
IA/IN
MA/MN

400V 380-420V
10-3 kgm2 kg

750/1500 min-1 (8/4 poles) - Dahlander connection Y/YY


AMV 71Z AA

8/4

0.08/0.37

0.11/0.5

660/1370

1.2/2.6

26/57

0.63/0.72

0.60/1.25

0.65/1.35

2.8/3.4

1.9/1.7

1.24

6.8

AMV 80Z AA
AMV 80Z BA

8/4
8/4

0.12/0.55
0.18/0.75

0.16/0.75
0.25/1.0

685/1420
660/1380

1.7/3.7
2.6/5.2

50/69
53/67

0.60/0.74
0.73/0.81

0.58/1.53
0.65/1.9

0.65/1.6
0.7/2.0

1.9/3.3
2.0/3.5

1.4/1.5
1.6/1.7

2.47
2.41

9.2
10.6

AMV 90L AA
AMV 90L CA

8/4
8/4

0.18/1.1
0.4/1.6

0.25/1.5
0.54/2.15

680/1400
675/1400

2.5/7.5
5.7/10.9

60/70
61.5/75

0.65/0.82
0.64/0.79

0.9/2.7
1.8/4.0

1.0/2.8
1.8/4.1

2.8/4.0
3.1/5.0

1.5/2.0
1.6/2.2

2.98
3.70

15.7
19.6

AMV 100L AA
AMV 100L BA

8/4
8/4

0.45/2.2
0.6/2.6

0.60/3.0
0.80/3.5

680/1420
680/1435

6.3/14.8
8.4/17.3

63.1/75.3
64.0/76.2

0.60/0.80
0.63/0.75

1.7/5.0
2.2/6.5

1.9/5.3
2.3/6.7

2.7/4.7
2.7/4.8

1.7/2.0
1.7/2.2

5.58
6.00

21.9
23.7

AMV 112M AA 8/4


AMV 112M CA 8/4

0.7/3.3
1.0/4.0

0.94/4.5
1.34/5.5

690/1420
720/1420

9.7/22.2
13.3/26.9

62/78
60/77

0.70/0.80
0.70/0.82

2.2/7.4
3.1/8.6

2.3/7.6
3.3/9.0

3.4/6.5
3.5/5.0

1.8/2.4
2.3/1.9

16.70
19.50

34.2
40.0

AMV 132S AA 8/4


AMV 132M BA 8/4
AMV 132M CA 8/4

1.1/4.5
1.4/5.5
1.8/7.5

1.5/6.1
1.9/7.5
2.4/10.2

725/1450
720/1440
720/1450

14.5/29.6
18.6/36.5
23.9/49.4

77.0/85.5
78.0/86.0
78.2/86.5

0.58/0.82
0.62/0.82
0.64/0.86

3.6/9.3
4.2/11.3
5.2/14.6

4.0/9.7
4.5/12
5.5/15.0

3.5/5.4
3.6/5.5
4.6/6.0

2.2/2.7
2.0/2.5
2.0/2.5

22.4
29.25
37.25

41.9
51.0
65.0

AMV 160M ZA
AMV 160L ZA

2.2/10.0 3.0/13.0 720/1450


3.2/15.0 1) 4.3/20.0 1) 720/1450

29.2/65.9
42.4/98.8

80.0/88.0
81.0/90.0

0.61/0.83
0.61/0.88

6.6/19.9
9.4/27.3

6.8/20.4
9.8/28

3.5/6.0
3.5/6.5

1.8/1.7
1.7/1.8

81.25 88.5
105.75 106.5

8/4
8/4

1) Temperature rise to class F

Three-Phase Motors - Technical Catalogue 1031/11

For mains voltage


to IEC 60038
400 V 10% - 50 Hz

Three-phase pole-changing motors for fan


drives designed for range of rated voltage
380-420 V 5% - 50 Hz

[ T]

Temperature rise to class B



Type

kW

HP

min-1

MN
Nm


cos
100%

IN
IA/IN
MA/MN

400V 380-420V
10-3 kgm2 kg

1500/1000 min-1 (4/6 poles) - separate windings


AMV 71Z AA
AMV 71Z BA

4/6
4/6

0.25/0.08
0.37/0.13

0.33/0.11
0.50/0.18

1370/900
1360/880

1.7/0.4
2.6/1.4

60/40
62/44

0.80/0.70
0.80/0.70

0.75/0.4
1.0/0.6

0.8/0.45
1.1/0.7

3.0/2.5
3.2/2.6

1.6/1.6
1.6/1.6

1.15
1.24

6.7
7.2

AMV 80Z AA
AMV 80Z BA

4/6
4/6

0.55/0.18
0.75/0.25

0.75/0.25
1.0/0.33

1380/920
1400/940

3.8/1.9
5.1/2.5

60/42
70/60

0.83/0.82
0.82/0.72

1.60/0.75
1.8/0.8

1.7/0.8
1.9/0.9

3.5/2.4
4.2/2.6

1.6/1.0
1.6/1.3

1.97
4.05

8.3
14

AMV 90S AA
AMV 90L BA
AMV 90L CA

4/6
4/6
4/6

0.75/0.24
1.1/0.37
1.5/0.5

1.0/0.32
1.5/0.50
2.0/0.67

1400/950
1400/930
1420/950

5.1/2.4
7.5/3.8
10.1/5

70/60
70/60
73/64

0.82/0.72
0.81/0.74
0.80/0.70

1.9/0.8
2.8/1.2
3.52/1.52

2.0/0.9
3.0/1.3
3.7/1.6

4.2/2.6
4.3/2.7
4.8/2.6

1.6/1.3
1.6/1.2
1.5/1.3

4.05
4.78
5.98

14
16.4
20.5

AMV 100L AA
AMV 100L BA

4/6
4/6

1.85/0.60
2.2/0.75

2.5/0.75
3.0/1.0

1400/920
1420/950

12.6/6.2
14.8/7.5

74/64
76/66

0.80/0.73
0.79/0.75

4.6/1.9
5.1/2.1

4.8/2.1
5.3/2.2

4.8/3.1
5.0/3.5

1.8/1.5
1.7/1.3

6.73
9.25

23.4
22.6

3/1.0

4.0/1.34

1440/970

19.9/9.8

80/73

0.81/0.65

6.6/3.0

6.8/3.2

5.8/4.6

2.5/2.1

13.3

30.4

5.2/1.8
6.0/2.0
7.5/2.4
8.6/3.0 1)

1460/970
1460/970
1460/970
1460/970

24.9/12.8
28.8/14.8
36/17.7
41.2/21.7

85.0/75.0
86.0/78.2
86.8/80.0
86.8/81.0

0.8/0.72
0.85/0.73
0.84/0.74
0.84/0.73

8.1/3.5
8.7/3.8
10.9/4.4
12.5/5.4

8.5/4
9.2/4.3
12.0/4.
13.5/5.

6.5/4.0
6.5/4.4
7.0/4.7
7.2/4.8

2.2/1.7
2.2/1.7
2.6/1.8
2.6/1.9

22.4
29.25
37.25
37.25

41.9
51.0
65.0
66.0

7.5/2.5
10.0/3.4
11.0/3.7 15.0/5.0
13.0/4.0 1) 17.7/5.4 1)

1470/975
1470/970
1460/970

48.7/24.5
71.5/36.4
85/39.4

87.5/83.0
88.0/84.2
88.0/84.5

0.83/0.75
0.81/0.73
0.81/0.72

14.9/5.8
22.5/8.7
26.3/9.5

15.6/6.0
23.4/9.0
27.5/10

8.3/4.5
8.0/4.8
8.0/4.8

2.5/1.9
2.4/1.8
2.4/1.9

81.25 88.5
105.75 106.5
105.75 106.5

AMV 112M AA 4/6









AMV 132S AA
AMV 132M BA
AMV 132M CA
AMV 132M DA

4/6
4/6
4/6
4/6

AMV 160M AA 4/6


AMV 160L BA 4/6
AMV 160L CA 4/6

3.8/1.3
4.4/1.5
5.5/1.8
6.3/2.2 1)


Type

kW

HP

min-1

MN
Nm


cos
100%


IN
IA/IN
MA/MN

400V 380-420V
10-3 kgm2 kg

1000/750 min-1 (6/8 poles) - separate windings


AMV 80Z AA
AMV 80Z BA

6/8
6/8

0.25/0.11
0.37/0.15

0.33/0.15
0.50/0.25

930/720
920/715

2.6/1.5
3.8/2

53/49
52/47

0.79/0.62
0.81/0.63

0.9/0.55
1.3/0.8

1.0/0.7
1.4/0.9

2.9/3.0
2.8/2.8

1.6/1.8
1.4/1.9

1.97
2.47

7.9
9.5

AMV 90L AA
AMV 90L BA

6/8
6/8

0.55/0.22
0.75/0.30

0.75/0.30
1.0/0.40

960/740
940/720

5.5/2.8
7.6/4

65/47
64/45.5

0.62/0.51
0.67/0.52

2.0/1.4
2.5/1.85

2.1/1.5
2.7/1.9

3.9/2.9
3.4/2.6

2.5/2.1
2.2/1.9

4.78
4.78

16.2
16.2

AMV 100L AA 6/8

1.1/0.45

1.5/0.60

950/710

11.1/6.1

70.6/58

0.71/0.67

3.1/1.7

3.3/1.8

4.3/2.8

2.0/1.3

9.43

22.0

AMV 112M AA 6/8

1.5/0.6

2.0/0.80

970/720

14.8/8

75.8/65

0.65/0.60

4.4/2.3

3.7/2.5

5.5/3.4

2.8/2.1

18.70

39.0

AMV 132S ZA 6/8


AMV 132M YA 6/8
AMV 132M ZA 6/8

2.2/0.9
3/1.2
4/1.6

3.0/1.2
4.0/1.6
5.5/2.2

970/715
960/715
960/715

21.7/12
29.8/16
39.8/21.4

78.0/69.0
80/72
81.0/74.0

0.67/0.55
0.7/0.55
0.78/0.6

6.1/3.5
7.8/4.4
9.2/5.2

6.7/4.0
8.2/4.8
9.8/5.6

4.8/4.0
4.8/4.1
5.3/4.4

1.6/1.6
1.6/1.6
1.7/1.7

29.5
37.75
44.5

42.5
55.5
64.1

AMV 160M YA 6/8


AMV 160M ZA 6/8

5.5/2.2
7/3

7.5/3.0
9.5/4.1

970/730
970/730

54.1/28.8
68.9/39.2

83/76
84/77

0.77/0.6
0.80/0.65

12.5/7
15/8.7

13.5/7.5
16/9.3

5.7/5.6
6.0/5.8

1.6/1.9
1.7/2.2

112.7 88.0
150.25 97.5

1) Temperature rise to class F

[52]

[53]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

Three-phase fr ame siz e 56 - 160 IM B3


AM SERIES - ALUMINIUM ALLOY FRAME

LC
L
AL

AD

AD
H
HA

GD

IEC
DIN

H
h

A
b

B
a

HC

AC

HD

DA

EA

GA

DB

AF

C
w1

K 1)
s

AB
f

AA

BA
BB
B

LB

K1

AB

CA

BB
CA
e

AD 2)
HD 2)
g4

AC
m1

HC
g

HA

56

56

90

71

36

107

86

64

92

148

110

109

63

63

100

80

40

120

100

72

96

159

124

120

71

71

112

90

45

135

108

83

110

181

139

142

80

80

125

100

50

10

153

125

89

129

209

160

162

9.5

90S
90L

90
90

140
140

100
125

56
56

10
10

170
170

150
150

116
91

138
138

228
228

180
180

181
181

11
11

100L

100

160

140

63

11

192

166

110

145

245

196

198

12

112M

112

190

140

70

12.5

220

175

126

161

273

225

226

15

132S
132M
132M 4)

132
132
132

216
216
216

140
178
178

89
89
89

12
12
12

256
256
256

180
218
218

134
136
166

195
195
195

327
327
327

248
248
248

261
261
261

17
17
17

160M
160L
160L 5)

160
160
160

254
254
254

210
254
254

108
108
108

14
14
14

320
320
320

270
310
310

180
180
210

238
238
238

398
398
398

317
317
317

316
316
316

23
23
23

K1
c

IEC
DIN

L
LB
k

LC
AL
AF
k1

BA
m

AA
n

D/DA
d/d1

E/EA
l/l1

F/FA
GD
u/u1

GA/GC DB 3)
t/t1
d6/d7

56

188

168

211

61

92

27

27

20

10.2

M3

63

11

211

188

238

63

92

29

30

11

23

12.5

M4

71

11

246

216

278

69

92

28

31

14

30

16

M5

80

14

272

232

319

79

116

28.5

34.5

19

40

21.5

M6

90S
90L

15
15

317
317

267
267

372
372

85
85

116
116

28/53
28/53

37
37

24
24

50
50

8
8

7
7

27
27

M8
M8

100L

17

366

306

433

91

116

38

44

28

60

31

M10

112M

19

388

328

456

91.5

116

46

48

28

60

31

M10

132S
132M
132M 4)

20
20
20

442
482
500

362
402
420

523
563
593

100
120
120

133
133
133

45
45
45

59
59
59

38
38
38

80
80
80

10
10
10

8
8
8

41
41
41

M12
M12
M12

160M
160L
160L 5)

18
18
18

608
652
678

498
542
568

718
762
678

146
168
168

150
150
150

65
65
65

76
76
76

42
42
42

110
110
110

12
12
12

8
8
8

45
45
45

M16
M16
M16

1)
2)
3)
4)
5)

Clearance hole for screw


Maximum dimension
Centering holes in shaft extensions to DIN 332 part 2
Only for MT A2
Only for LR A4

Three-Phase Motors - Technical Catalogue 1031/11

Three-phase frame size 180 - 315 IM B3


AM SERIES - CAST IRON FRAME

H
h

A
b

B
a

C
W

K 1)
s

AB
f

BB
e

AD
g4

HD
m1

AC
g

180M
180L

180
180

279
279

241
279

121
121

15
15

348
348

310
348

259
259

439
439

360
360

200L

200

318

305

133

19

388

368

297

497

399

IEC Poles
DIN

225S
225M

4
2
4

225
225
225

356
356
356

286
311
311

149
149
149

19
19
19

436
436
436

361
386
386

328
328
328

553
553
553

465
465
465

250M

2
4

250
250

406
406

349
349

168
168

24
24

484
484

443
443

366
366

616
616

506
506

280S

2
4
2
4

280
280
280
280

457
457
457
457

368
368
419
419

190
190
190
190

24
24
24
24

557
557
557
557

459
459
510
510

388
388
388
388

668
668
668
668

559
559
559
559

2
4
2
4
2
4

315
315
315
315
315
315

508
508
508
508
508
508

406
406
457
457
508
508

216
216
216
216
216
216

28
28
28
28
28
28

630
630
630
630
630
630

590
590
672
672
672
672

525
525
525
525
525
525

840
840
840
840
840
840

680
680
680
680
680
680

HA
c

L
k

LB

AL

AA
n

D
d

E
l

F
u

GD

GA
t

DB 2)
d6

180M
180L

27
27

687
725

577
615

261
261

75
75

48
48

110
110

14
14

9
9

51.5
51.5

M16
M16

200L

25

768

658

285

80

55

110

16

10

59

M20

280M

315S
315M
315L

IEC Poles
DIN

225S
225M

4
2
4

28
28
28

814
809
839

674
699
699

295
295
295

85
85
85

60
55
60

140
110
140

18
16
18

11
10
11

64
59
64

M20
M20
M20

250M

2
4

30
30

918
918

778
778

342
342

80
80

60
65

140
140

18
18

11
11

64
69

M20
M20

280S

2
4
2
4

34
34
34
34

984
984
1035
1035

844
844
895
895

400
400
400
400

100
100
100
100

65
75
65
75

140
140
140
140

18
20
18
20

11
12
11
12

69
79.5
69
79.5

M20
M20
M20
M20

2
4
2
4
2
4

45
45
45
45
45
45

1160
1190
1310
1340
1310
1340

1020
1020
1170
1170
1170
1170

292
292
292
292
292
292

120
120
120
120
120
120

65
80
65
80
65
80

140
170
140
170
140
170

18
22
18
22
18
22

11
14
11
14
11
14

69
85
69
85
69
85

M20
M20
M20
M20
M20
M20

280M

315S
315M
315L

[54]

[55]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

[ T]

HIGH EFFICIENCY THREE-PHASE MOTORS IM B3


AMHE - AMPE* SERIES
*Only AMPE 2 poles motors. For AMPE 4 poles motors, please consult us

LC
L
AL

AD

AD
H
HA

GD

IEC
Poles
kW
DIN

HC

AC

HD

DA

EA

GA

DB

AF

AA

BA
BB
B

AB

CA

LB

K1

H
h

A
b

B
a

C
w1

K 1)
s

AB
f

BB
CA
AD 2)
e

HD 2)
g4

AC
m1

HC
g

71

0.75

71

112

90

45

135

108

83

110

181

139

142

80

2 - 4

all

80

125

100

50

10

153

125

89

129

209

160

162

90S
90L

2 - 4
2 - 4

all
all

90
90

140
140

100
125

56
56

10
10

170
170

150
150

116
91

138
138

228
228

180
180

181
181

100L

2
4
4

all
2.2
3

100
100
100

160
160
160

140
140
140

63
63
63

11
11
11

192
192
192

166
166
166

110
110
144

145
145
145

245
245
245

196
196
194

198
198
198

112M

2
2
4

4 - 5.5
7.5
all

112
112
112

190
190
190

140
140
140

70
70
70

12.5
12.5
12.5

220
220
220

176
176
176

126
148
126

160
160
160

272
272
272

225
222
225

225
225
225

132S

2
2
4

5.5
7.5
5.5

132
132
132

216
216
216

140
140
140

89
89
89

12
12
12

256
256
256

180
180
180

134
154
134

194
194
194

326
326
326

248
248
248

261
261
261

132M

2
2
4

9.2 - 11
15
all

132
132
132

216
216
216

178
178
178

89
89
89

12
12
12

256
256
256

218
218
218

156
207
136

194
194
194

326
326
326

248
248
248

261
261
261

160M

2 - 4

all

160

254

210

108

14

320

270

180

238

398

317

316

160L

2 - 4

all

160

254

254

108

14

320

310

180

238

398

317

316

IEC
Poles kW
HA
DIN

K1
c

L
LB
k

LC
AL
AF
k1

BA
m

AA
n

D/DA
d/d1

E/EA
l/l1

F/FA GD/GF GA/GC DB/DC 3)


u/u1
t/t1
d6/d7

71

0.75

11

246

216

278

69

92

28

31

14

30

16

M5

80

2 - 4

all

9.5

14

272

232

319

79

116

28.5

34.5

19

40

21.5

M6

90S
90L

2 - 4
2 - 4

all
all

11
11

15
15

317
317

267
267

372
372

85
85

116
116

28/53
28/53

37
37

24
24

50
50

8
8

7
7

27
27

M8
M8

100L

2
4
4

all
2.2
3

12
12
12

17
17
17

366
366
400

306
306
340

433
433
467

91
91
91

116
116
116

38
38
38

44
44
44

28
28
28

60
60
60

8
8
8

7
7
7

31
31
31

M10
M10
M10

112M

2
2
4

4 - 5.5
7.5
all

15
15
15

19
19
19

388
410
388

328
350
328

456
478
456

92
92
92

116
116
116

46
46
46

48
48
48

28
28
28

60
60
60

8
8
8

7
7
7

31
31
31

M10
M10
M10

132S


132M

2
2
4
2
2
4

5.5
17
7.5
17
5.5
17
9.2 - 11 17
15
17
all
17

20
20
20
20
20
20

445
465
445
505
556
485

365
385
365
425
476
405

523
543
523
583
634
563

100
100
100
120
120
120

133
133
133
133
133
133

45
45
45
45
45
45

59
59
59
59
59
59

38
38
38
38
38
38

80
80
80
80
80
80

10
10
10
10
10
10

8
8
8
8
8
8

41
41
41
41
41
41

M12
M12
M12
M12
M12
M12

160M
160L

2 - 4
2 - 4

all
all

18
18

608
652

498
542

668
712

146
168

150
150

65
65

76
76

42/28
42/28

110/60
110/60

12/8
12/8

8/7
8/7

45/31
45/31

M16/M10
M16/M10

23
23

1) Clearance hole for screw


2) Maximun distance
3) Centering holes in shaft extensions to DIN 332 part 2

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

HI G H EF F I CI ENCY TH RE E -PH ASE MO T ORS IM B3


AMH - AMPH * SE RIE S
*Only AMPH 2 poles motors. For AMPH 4 poles motors, please consult us

LC
L
AL

AD

AD
H
HA

GD

HC

AC

HD

DA

EA

GA

DB

AF

IEC
Poli
kW
DIN

AA

BA
BB
B

AB

CA

LB

K1

H
h

A
b

B
a

C
K 1)
w1

AB
s

BB
f

CA
AD 2)
e

HD 2)
g4

AC
m1

HC
g

80

2 - 4

all

80

125

100

50

10

153

125

89

129

209

160

162

90S
90L

2 - 4
2 - 4

all
all

90
90

140
140

100
125

56
56

10
10

170
170

150
150

116
91

138
138

228
228

180
180

181
181

100L

2
4
4

all
2.2
3

100
100
100

160
160
160

140
140
140

63
63
63

11
11
11

192
192
192

166
166
166

110
110
144

145
145
145

245
245
245

196
196
194

198
198
198

112M

2 - 4

all

112

190

140

70

12,5

220

176

126

160

272

225

225

132S


132M

2
2
4
2
4

5.5
7.5
5.5
all
all

132
132
132
132
132

216
216
216
216
216

140
140
140
178
178

89
89
89
89
89

12
12
12
12
12

256
256
256
256
256

180
180
180
218
218

134
154
134
156
136

194
194
194
194
194

326
326
326
326
326

248
248
248
248
248

261
261
261
261
261

160M
160L

2 - 4
2 - 4

all
all

160
160

254
254

210
254

108
108

14
14

320
320

270
310

180
180

238
238

398
398

317
317

316
316

IEC
Poles kW
HA
DIN

K1
c

L
LB
k

LC
AL
AF
k1

BA
m

AA
n

D/DA
d/d1

E/EA
l/l1

F/FA GD/GF GA/GC DB/DC 3)


u/u1
t/t1
d6/d7

80

2 - 4

all

9.5

14

272

232

319

79

116

28.5

34.5

19

40

21.5

M6

90S
90L

2 - 4
2 - 4

all
all

11
11

15
15

317
317

267
267

372
372

85
85

116
116

28/53
28/53

37
37

24
24

50
50

8
8

7
7

27
27

M8
M8

100L

2
4
4

all
2.2
3

12
12
12

17
17
17

366
366
400

306
306
340

433
433
467

91
91
91

116
116
116

38
38
38

44
44
44

28
28
28

60
60
60

8
8
8

7
7
7

31
31
31

M10
M10
M10

112M

2 - 4

all

15

19

388

328

456

92

116

46

48

28

60

31

M10

132S


132M

2
2
4
2
4

5.5
7.5
5.5
all
all

17
17
17
17
17

20
20
20
20
20

445
465
445
505
485

365
385
365
425
405

523
543
523
583
563

100
100
100
120
120

133
133
133
133
133

45
45
45
45
45

59
59
59
59
59

38
38
38
38
38

80
80
80
80
80

10
10
10
10
10

8
8
8
8
8

41
41
41
41
41

M12
M12
M12
M12
M12

160M
160L

2 - 4
2 - 4

all
all

23
23

18
18

608
652

498
542

668
712

146
168

150
150

65
65

76
76

42/28
42/28

110/60
110/60

12/8
12/8

8/7
8/7

45/31
45/31

M16/M10
M16/M10

1) Clearance hole for screw


2) Maximun distance
3) Centering holes in shaft extensions to DIN 332 part 2

[56]

[57]

Three-Phase Motors - Technical Catalogue 1031/11

[ T]

Three-phase fr ame siz e 56 - 160 IM B14, IM B5


AM-AMHE-AMH-AMPE-AMPH SERIES - ALUMINIUM ALLOY FRAME

IMB14

IMB5
T

S
M

DB

GA

GD

LA

LA

E
E

Small flange B14

IEC

P
a1

DIN
56

80

Large flange B14

Flange B5

N
b1

LA
c1

M
e1

T
f1

S
s1

P
a1

N
b 1

LA
c1

M
e1

T
f1

S
s1

M
e1

N
b1

P
a1

T
f1

LA
c1

S1)
s1

50

65

2.5

M5

105

70

85

2.5

M6

100

80

120

2.5

M6

63

90

60

75

2.5

M5

120

80

100

2.5

M6

115

95

140

M8

71

105

70

85

2.5

M6

140

95

115

M8

130

110

160

3.5

10

M8

80

120

80

100

M6

160

110

8.5

130

3.5

M8

165

130

200

3.5

10

M10

90S-L

140

95

115

M8

160

110

130

3.5

M8

165

130

200

3.5

12

M10

100L

160

110

10

130

3.5

M8

200

130

12

165

3.5

M10

215

180

250

14

M12

112M

160

110

10

130

3.5

M8

200

130

12

165

3.5

M10

215

180

250

14

M12

132S-M

200

130

30

165

3.5

M10

250

180

12

215

M12

265

230

300

14

M12

160M-L

250

180

12

215

M12

300

230

12

265

M16

300

250

350

15

M16

GA
t

DB1)
d6

1) Clearence hole for screw. Hole as standard for 132 to 160 frame size

GA

GD

DB

EB

EG

ED

IEC
DIN

D
d

E
l

F h9
GD
u

EG

EB

ED

56

9 j6

20

10.2

M3

10

15

2.5

63

11 j6

23

12.5

M4

10

15

71

14 j6

30

16

M5

12.5

20

80

19 j6

40

21.5

M6

16

30

90S-L

24 j6

50

27

M8

19

40

100L

28 j6

60

31

M10

22

50

112M

28 j6

60

31

M10

22

50

132S-M

38 k6

80

10

41

M12

28

70

160M-L

42 k6

110

12

45

M16

36

100

1) Centering holes in shaft extension to DIN 332 part 2


Three-Phase Motors - Technical Catalogue 1031/11

[ T]

Three-phase frame size 180 - 315 IM B5


AM SERIES - CAST IRON FRAME

P
a1

T
f1

LA
c1

S 1)
s1


180M
4
300
250
350
5
180L
4
300
250
350
5
200L
4
350
300
400
5
225S
4
400
350
450
5
225M
2
400
350
450
5

4
400
350
450
5
250M
2
500
450
550
5

4
500
450
550
5
280S
2
500
450
550
5

4
500
450
550
5
280M
2
500
450
550
5

4
500
450
550
5
315S
2
600
550
660
6

4
600
550
660
6
315M
2
600
550
660
6

4
600
550
660
6
315L
2
600
550
660
6

4
600
550
660
6

15
15
17
20
20
20
20
20
22
22
22
22
22
22
22
22
22
22

19
19
19
19
19
19
19
19
19
19
19
19
24
24
24
24
24
24

GA
t

DB 2)
d6

51.5
51.5
59
64
59
64
64
69
69
79.5
69
79.5
69
85
69
85
69
85

M16
M16
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20


Poles
D
E
F
GD

d
l
u

180M
4
48
110
14
9
180L
4
48
110
14
9
200L
4
55
110
16
10
225S
4
60
140
18
11
225M
2
55
110
16
10

4
60
140
18
11
250M
2
60
140
18
11

4
65
140
18
11
280S
2
65
140
18
11

4
75
140
20
12
280M
2
65
140
18
11

4
75
140
20
12
315S
2
65
140
18
11

4
80
170
22
14
315M
2
65
140
18
11

4
80
170
22
14
315L
2
65
140
18
11

4
80
170
22
14

GA

N
b1

GD

EB

ED

DB

M
e 1


Poles

EG

1) Clearence hole for screw


2) Centering holes in shaft extension to DIN 332 part 2

[58]

[59]

Three-Phase Motors - Technical Catalogue 1031/11

All technical data, outputs, dimensions and weights stated in this catalogue are subject to
change without prior notice.
The illustrations are not binding.
Printed in March 2011.

btobcomunica.com

1031/11

Partners & Filiali


Lafert GmbH
Olgastrae 34/1
D - 73728 Esslingen - Germany
Phone +49 / (0) 711 540 3095 + 7
Fax +49 / (0) 711 540 3098
[email protected]

Lafert Electric Motors Ltd.


Electra House - Electra Way
Crewe, Cheshire CW1 6GL
United Kingdom
Phone +44 / (0) 1270 270 022
Fax +44 / (0) 1270 270 023
[email protected]

Lafert Moteurs S.A.S.


LIsle dAbeau Parc de Chesnes
75, rue de Malacombe
F - 38070 St. Quentin-Fallavier
France
Phone +33 / 474 95 41 01
Fax +33 / 474 94 52 28
[email protected]

Lafert Motores Elctricos, S.L.


Polgono Pignatelli, Nave 27
E - 50410 Cuarte de Huerva
(Zaragoza) - Spain
Phone +34 / 976 503 822
Fax +34 / 976 504 199
[email protected]

Lafert N.A. (North America)


5620 Kennedy Road - Mississauga
Ontario L4Z 2A9 - Canada
Phone +1 / 800/661 6413 - 905/629 1939
Fax +1 / 905/629 2852
[email protected]

Lafert Electric Motors (Australia)


Unit 3 - 891 Princes Highway
AUS - Springvale VIC 3171 - Australia
Phone +61 / (03) 9546 7515
Fax +61 / (03) 9547 9396
[email protected]

Lafert Singapore Pte Ltd


48 Hillview Terrace #03-08
Hillview Building - Singapore 669269
Phone +65 / 67630400 - 67620400
Fax +65 / 67630600
[email protected]

ENERGY EFFICIENT Motors

CUSTOMISED Motors

HIGH PERFORMANCE Motors

Lafert S.p.A.
Via J.F. Kennedy, 43
I - 30027 San Don di Piave
Venezia - Italy
Phone +39 / 0421 229 611
Fax +39 / 0421 222 908
[email protected]

SERVO Motors & Drives

www.lafert.com

LIFT Motors