Intelligent Input Module I-9300

Technical Specifications Test Standard: CEA-GE1.084:2000 Protection rating: IP 32 Approval: LPCB, CE Input: programmable NO/NC Operating voltage: 24Vdc Loop voltage Operating Current: Monitoring current: 1mA Action Current: 5mA Operating temperature: -10C to +55C Relative humidity: 95% EOL Resistor : 4.7 K ohms Addressing: 242 using P-9910 Application: Indoor use Visual Indicator: LED, steady red when in alarm state, 3 sec interval blinking at normal state; Yellow (fault) Material and colour: ABS, off-white Wiring: 1 pair non polarized Dimensions: 120mmx80mmx40mm

Features and Benefits


1. 2. 3. 4. 5. 6. 7. Monitors switch contacts of remote equipment Monitored cable Programmable Inputs (NO/NC) Loop powered Electronically addressed LED status indicator First fix base for easy and safe installation

Mounting Module Base The module should be installed in compliance with all local codes and/or NFPA 72 National Fire Alarm Code, NFPA 70 National Electrical Code, BS5389, and EN45. It is installed onto a standard one gang electrical box with a mounting hole that have 6.5cm spacing.

Description
I-9300 Intelligent Input Module is used to receive normally open or normally closed control signals from interfaced equipment, and transmit the messages back to fire alarm control panel. The units ideal for use in water flow indicator, pressure switch, position switch, signal valves and external interface devices. When these devices operate, the output signal can be transmitted to fire alarm control panel via the module through the fire alarm loop to generate alarm, and activate other relevant devices. Electronic addressing can be done through Handheld Programming tool (P-9910B), purchased separately.

I9300

WALL ELECTRICAL BACK BOX

Addressable Input Module

Action

MOUNTING BASE

Addressable Input Module I-9300


Programming Wiring and Connection Connect the wires to the required terminal according to the wiring diagram. The Z1 (14), Z2 (15) connect to addressable fire detection loop, non-polarized, while G (11) and I1 (12) connect to field device passive contact. The cable must be fire rated type and the size depends on the distance and application. Minimum size gauge 1.0mm(18 AWG) The address of the module and device parameters can be programmed using GST handheld programmer (P-9910B), purchased separately. Connect the two wires of the handheld programmer to Z1 (14), Z2 (15) terminals of the module.fig1

10 11 12 13 14 15 16 G I1 Z1 Z2

1 2 3

16 15 14 13 12 11 10 9

INPUT N/O Parallel 4.7kohms Cable Monitoring


Z1 (14) AND Z2 (15) TERMINAL

LOOP IN

LOOP OUT

Parameter 1

FIELD DEVICE PROGRAMMER


1

10 11 12 13 14 15 16 G I1 Z1 Z2

Selection of compatible Control Panels


INPUT N/O Ex. flow switch

Compatible with all GST Intelligent Fire Alarm Panels GST200-2, GST5000, GSTIFP8.
LOOP OUT

LOOP IN

Parameter 4 (Default)

Ordering Information:
Part No I-9300 Description Addressable Input Module Weight /Kg .180 Pack Qty per Box 120