Loop-ADM LoopTelecom O9100-V12
Loop-ADM LoopTelecom O9100-V12
Features
TM, ADM, REGENERATOR Fully front access option Multiple Tributary modules: 28 E1/T1 on base unit 4/ 12/ 20/ 28-channel E1/T1 plug-in card (not hot-pluggable) Redundant hot-swappable AC/DC power card for ANSI shelf only SNCP/UPSR protection Optional MSP (1+1) protection Rack mount, Wall mount, and Stand-Alone Centralized management with Loops EMS/NMS over DCC channel External/Internal/Line timing Support VCAT (Phase-I Function), GFP (Phase-I Function), and LCAS (Phase-II Function) Up to 112 x E1/T1 add/drop Performance monitoring Alarm suppression, masking, and report
With up to 4 aggregate optical/electrical STM-1 interfaces, the Loop-ADM can offer the service provider a versatile protection scheme including SNCP and MSP(1+1) protection for both ring and linear Network topology. All interfaces are fully compliant with the relevant ETSI standards and ITU recommendations. The Loop-ADM provides powerful Operation, Administration, Maintenance and Provisioning (OAM&P) functionality, including fault management, performance monitoring, configuration management, and network security management. Through console port, LAN port, and DCC channel, the OAM&P can be achieved both locally and remotely via SNMP or menu-driven interfaces. Powerful SDH Loops EMS/NMS The Loop-ADM provides a completely set of operation interfaces that are consistent with the Telecommunication Management Network (TMN) concept (ITU Recommendation M.30, G.784) for SDH Network Element/ Operations System (NE/OS), NE/NE, and NE/Craft communications. User can easily operate Loop-ADM both locally or remotely for centralized management.
CERTIFIED ISO-9001
Ordering Information
Model Main Unit Loop-O 9100-1UA-h-n-ver-Add Loop-O 9100-1UE-h-n-A-A-ver-Add Loop-O 9100-3UA-n-ver-Add Loop-O 9100-3UE-n-1A-1A-ver-Add Loop-O 9100-3UE-n-2A-0A-ver-Add 1U height ANSI (rear & front access) shelf 1U height ETSI (fully front access) shelf 3U height ANSI (rear & front access) shelf 3U height ETSI (fully front access) shelf for SNCP (Sub-Network Connection Protection) 3U height ETSI (fully front access) shelf for trunk modules 1 for 1 protection 3U height ETSI (fully front access) shelf for SNCP (Sub-Network Connection Protection) & one trunk module 1 for 1 protection 3U height ETSI (fully front access) shelf for SNCP (Sub-Network Connection Protection) & two trunk modules 1 for 1 protection where h, n, A, ver, pp1, pp2, and Add are defined in below tables The 1st A is for east-side trunk, the 2nd A is for west-side trunk 0A for no trunk module, 1A for one trunk module, 2A for two trunk modules (1 for 1 protection). Description Note
Loop-O 9100-3UE-n-2A-1A-ver-Add
Loop-O 9100-3UE-n-2A-2A-ver-Add
Plug-in Tributary Module for 3U shelf only: Loop-O 9100-28E75 28E1 plug-in module w/ 75 ohm Loop-O 9100-28E120 Loop-O 9100-28T1 Loop-O 9100-3DS3 28E1 plug-in module w/ 120 ohm 28T1 plug-in module 3-port DS3 module For 3U shelf only Select 1 to 3 cards from the list
Loop-O 9100-3E3 3-port E3 module Plug-in Trunk Module for ANSI shelf only: Loop-O 9100-TK-A Plug-in Power Module for 1U shelf: Loop-O 9100-1U-SA Loop-O 9100-1U-SD Loop-O 9100-1U-SD24 Loop-O 9100-1U-SD48 Plug-in Power Module for 3U shelf: Loop-O 9100-3U-SA Loop-O 9100-3U-SD Loop-O 9100-3U-SD24 Loop-O 9100-3U-SD48 Order Wire IP Phone Loop-O 9100-OW SIP Proxy Server Software Loop-O 9100-SIP Connector Panel Loop-O 9100-RJ Loop-O 9100-BNC Loop-O 9100-WW 28-port RJ48 connector panel 28-port BNC connector panel 28-port Wire-Wrap pins connector panel Include two 1m SCSI cables for each panel SIP Proxy Server Order Wire (VoIP) Phone Single AC power supply Single DC power supply (For 24Vdc and 48Vdc: 20 - 60 Vdc) Single DC power supply (24Vdc 18-36 Vdc) Single DC power supply (48Vdc: 36-75 Vdc) Single AC power supply Single DC power supply (For 24Vdc and 48Vdc: 20 - 60 Vdc) Single DC power supply (24Vdc 18-36 Vdc) Single DC power supply (48Vdc: 36-75 Vdc) All types of trunk module For 3U ANSI shelf only Where A is defined as below
where h is used to select chassis type for 1U shelf: On board Chassis h= 28E1 28E1 height E1/ T1 (75 ohm) (120 ohm) 100 101 102 103 104 105 106 107
Additional fixed module 28T1 1-port DS3 1-port E3 3-port DS3 3-port E3 Ethernet
1U Note
108 where n is used to select on-board E1/ T1 type: n= Description 4E75 4 E1 lines with 75 ohm 12E75 12 E1 lines with 75 ohm 20E75 20 E1 lines with 75 ohm 28E75 28 E1 lines with 75 ohm 4E120 4 E1 lines with 120 ohm 12E120 12 E1 lines with 120 ohm 20E120 20 E1 lines with 120 ohm 28E120 28 E1 lines with 120 ohm 4T 4 T1 lines 12T 12 T1 lines 20T 20 T1 lines 28T 28 T1 lines where A is used to select trunk module type: NOTE: The 1st A is for east-side trunk, the 2nd A is for west-side trunk. A= Description 0 None SAA SBB SCC SDD SEE SSM single optical module with dual uni-directional fiber, 1310 nm, SC optical connector, 30 km reach (20dB) single optical module with dual uni-directional fiber, 1310 nm, SC optical connector, 50 km reach (30dB) single optical module with dual uni-directional fiber, 1310 nm, FC optical connector, 30 km reach (20dB) single optical module with dual uni-directional fiber, 1550 nm, SC optical connector, 20 km reach (12dB) single optical module with dual uni-directional fiber, 1550 nm, SC optical connector, 100 km reach (40dB) single optical module with single bi-directional fiber (master), 1310 nm transmit and 1550 receive, SC optical connector, 30 km reach (20dB) single optical module with single bi-directional fiber (slave), 1310 nm receive and 1550 transmit, SC optical connector, 30 km reach (20dB) Electrical STM1/ OC3 module Other special optical modules for special order
Note Valid for 2nd A only Use 2 fibers Use 2 fibers Use 2 fibers Use 2 fibers Use 2 fibers 1310 nm from master to slave Order SSM to use with SSS Use 1 fiber 1550 nm from slave to master Order SSS to use with SSM Use 1 fiber
where ver is used to select shelf trunk multiplexing: ver = Description STM ITU STM1 as the trunk multiplexing where Add is used to select other additional options: Add = CO Ring closure Description Note
Application Illustrations
The Loop-ADM can be configured as either a Terminal Multiplexer (TM), a Linear Add/Drop Multiplexer (LADM), or an Optical Regenerator (OR) with the same enclosure. With SNCP and MSP(1+1) protection, the Loop-ADM can easily provide a well-protected transmission path in various applications shown as follows:
GSM Application
BSC (Base Station Controller)
BTS
E1
E1
BTS
E1
E1
BTS
BTS
BTS
V4100 UMAP
112 x E1/T1 6 x E3/T3 32 x ethernet
O9100 STM1 ADM
Regenerator
0 1
STM1 0 1
10/100
Ethernet Switch
E1/ T1 AM3440
E1/ T1 V4200-9
H3710 ADSL RT
E1200
U3500
E1500
H3300 G.shdsl
H3900 HDSL
PBX
PC LAN
AM3440
Fax PBX Video
V4200-9
Fax
AM3420
Hub
Video
V4200-28
ADM
ADM
STM 4/ 16 Ring
ADM O9100 STM1 ADM
ADM
V4100 UMAP
112 x E1
O9100 STM1 ADM
Remote Switch
E1
E1
Remote Switch
Remote Switch
E1
E1
Remote Switch
E1
Remote Switch
LoopTelecom.com
Worldwide
8F, No. 8, Hsin Ann Road, Science-Based Industrial Park Hsinchu, Taiwan 300 Tel:+886-3-578-7696 Fax:+886-3-564-6272 www.LoopTelecom.com sales@loop.com.tw
North America
8 Carrick Road Palm Beach Gardens Florida 33418, U.S.A. Tel:+1-561-627-7947 Fax:+1-561-627-6615 0007576940@mcimail.com jimber561@aol.com
Suzhou China
Tel:+86-512-6252-0456 Fax:+86-512-6252-7641 www.looptech.com.cn Info@looptech.com.cn Sales@looptech.com.cn
Tianjin China
Tel:+86-22-8789-2753 Fax:+86-22-8789-0344 Loop@loop-tj.com
P12 11/12