UT60A Computer Interface SoftwareEEE
UT60A Computer Interface SoftwareEEE
A.
System Requirements
To use UT60A Interface Program, you need the following hardware and software: An IBM PC or equivalent computer with 80486 or higher processor and 600 x 800 pixel or better monitor. Microsoft Windows 95 or above. At least 8MB of RAM. At least 8MB free space in hard drive. Can access to a local or a network CD-ROM. A free serial port. A mouse or other pointing device supported by Windows.
B.
To install UT60A Interface Program, please follow below procedure: Before install the interface program, make sure that the computer is running the Window 95 or above operating system. 1. -Insert the provided CD-ROM into CD-ROM drive. -Double-click the My Computer icon from the Windows desktop. -Locate the CD-ROM drive from the window, double-click the drive letter to display the folder of UT60A. -Double-click UT60A to display the contents of the folder. -Double-click the file Setup.Exe. 2. Follow the on-screen installation instructions. 3. The installation program will create a UT60A Interface Program folder. You will be prompted to select the kind of Program Folder you want to install; you should select UT60A Interface Program.
C.
To run the UT60A Interface Program, please do the followings: 1. Insert the supplied RS232C Interface Cable into the slot at the back of the meter and properly connect the other end of the cable to the serial port of computer as shown on below figure 1.
(figure 1) 2. 3. 4. From the Windows Start menu, choose Programs > UT60A Interface Program > UT60A Press COMSetup to select corresponding COM 1/ 2 / 3 / 4. Press Connect from menu bar to start the connection, the icon will be displayed.
Below is the full screen of the software shown on the computer (see figure 2):
Model UT60A:
Connect/Disconnect Button
Records Area
Graphic Area
(figure 2)
D.
During the connection, you can select the following functions by clicking the corresponding icon or the menu bar: Fill: Click the box to select fill-up graph or unclick to select line graph. Record: Setting the number of record to be shown on graphic. Clear: To clear all the current records graphics permanently. Save: To save current graphic into BMP format. The default file name is C:\DATA1.BMP. First: Go to the first graphic. Previous: Go to the previous graphic. Next: Go to the next graphic. Last: Go to the last graphic. Zoom In: To enlarge part of the graphic. To enlarge: left click the mouse and drag from top to bottom and left to right. To restore: left click the mouse and drag from bottom to top and right and left.
Next Graphic Selection Clear No. of records setting Save First Present Zoom In Previous Last
(figure 3)
Model UT60A:
E.
During the connection, you can select the following functions by clicking the corresponding icon or the menu bar: Repeat: Click the box to keep the repeated record, or unclick the box to ignore the repeated record. The repeated records will be shown in graphic no matter what the selection is. Sampling Interval: Click to enable sampling interval function, or unclick to disable the function Enter the sampling intervals time, the unit is second. Clear: To clear all the current records permanently. Open fils: To read records form old file (*.db) . Save as: To save all the current records to file *.txt*.xls*.db print: To print the current records.
Enable or disable Keep or ignore the repeated record Set the sampling Sampling interval
interval in second
(figure 4)
F.
MIN: The maximum value obtained MIN: The minimum value obtained. SetMax: Click to enable the SetMax function or unclick to disable. Enter the upper limit value in integer. It will only compare the current value obtained to the upper limit in integer, it does not identify range or function, SetMin: Click to enable the SetMin function or unclick to disable. Enter the lower limit value in integer. It will only compare the current value obtained to the upper limit in integer, it does not identify range or function. : OL!! The Meter is connected properly to the computer and data is recording. Overload, the recorded value exceeds the SetMax and SetMin value. It will be flashing and the computer will sound if loudspeaker is installed.
Model UT60A:
figure 5
Overload
G.
After testing, below list out a normal maximum number of records that a computer can be saved for users reference. The computer will slow down if it exceeds the maximum. 80486 computer: 1000 to 5000 records 80586 computer: 5000 to 50000 records Pentium 2 or up: 50000 records up To set the maximum number of records from the Recordof the menu bar.
Remarks: 1. If abnormal digits or symbols were found after installation, please remove font UNIT-A2 and then install new font set from FONT directory on the provided CD-ROM. 2. The software designed to display the current measured value from the Meter. When the data hold, Max or Min functions are enabled, it is normal that the Meter displayed value difference from the computer due to the Meter display has already locked. 3. No special notice or free replacement will be provided when update version is issued. You could download the most updated version from the web site www.uni-trend.com.
**END**
This operating manual is subject to change without notice. C Copyright 2001 Uni-Trend International Limited. All rights reserved. Manufacturer: Uni-Trend International Limited Rm901, 9/F, Nanyang Plaza 57 Hung To Road, Kwun Tong Kowloon Hong Kong Tel.: (852) 2950 9168 Fax.: (852) 2950 9303 Email: info@uni-trend.com http://www.uni-trend.com