F10 ultrasound doppler system Operator manual - mediana co., Ltd. Printed in Korea Section 1. Safety1 1. Warings2 1. Cautions2 Section 2. F10 4 2. Configuration4 2. How to use?6 2. Simple Clinic Information7 Section 3. How to use your F10?6 2. Operational Requirements6 2. General Information7 Section 4. Maintenance and Cleaning8 Section 5. Warranty1 6. Warings WARNING : be informed that it may cause serious injury or death
F10 ultrasound doppler system Operator manual - mediana co., Ltd. Printed in Korea Section 1. Safety1 1. Warings2 1. Cautions2 Section 2. F10 4 2. Configuration4 2. How to use?6 2. Simple Clinic Information7 Section 3. How to use your F10?6 2. Operational Requirements6 2. General Information7 Section 4. Maintenance and Cleaning8 Section 5. Warranty1 6. Warings WARNING : be informed that it may cause serious injury or death
Wonju Medical Industry Park, 1650-1 Donghwa-ri, Munmak-eup, Wonju-si, Gangwon-do, Korea Tel : ++82 2 542 3375 ++82 33 742 5400 Fax: ++82 2 542 7447 ++82 33 742 5483 Web: http://www.mediana.co.kr EU representative TECNOMED 2000 S.L. Valencia, 25 - 28012 Madrid Spain A7153-0 (0609) P/N : OPM(F10)EN (2009.08.17) F10 Ultrasound Doppler System OPERATOR MANUAL Medical Device 1 Operator manual Rev.00 Operator manual Rev.00 F10 F10 Table of Contents Section 1. Safety1 1.1 Safe Operation 1 1.2 Warings2 1.3 Cautions 2 Section 2. F10 4 2.1 F10 4 2.2 Configuration 4 2.3 Composition4 Section 3. How to use your F10 ?6 2.1 Operational Requirements6 2.2 How to use ? 6 2.3 Simple Clinic Information7 Section 4. Maintenance and Cleaning 7 General Information 8 Product Guarantee 9 Specifications10 Copyright Mediana Corporation 2009. All rights reserved. Printed in Korea Section 1. Safety 1.1 Safe Operation Examine the monitor and any accessories periodically to ensure that the cables, line cords, transducers, and instruments do not have visible evidence of damage that may affect patient safety or monitoring performance. The recommended inspection terval is once per week or less. Do not use the F10 if there is any isible sign of damage. Do not attempt to service th F10. Only qualified service person should attempt any needed internal servicing. Perform periodic safety testing to insure proper patient safety. This should include leakage current measurement and insulation testing. The commended testing interval is once per year. The F10 is not specified or intended for operation in conjunction with any other type of monitoring equipment except the specific devices that have been identified for use in this Operators Manual. 3 Operator manual Rev.00 F10 2 Operator manual Rev.00 F10 1.2 Warings WARNING : Be informed that it may cause serious injury or death to the patient, property damage, material losses against the Warning sign. 1.3 Cautions CAUTION : Be informed that it may cause no harm in life but lead to injury against the Caution sign. CAUTION : The relevant law restricts this device to sale by or on the order of a physician. CAUTION : Keep the operating environment free of dust, vibrations, corrosive, or flammable materials, and extremes of temperature and humidity. The unit should be kept clean and free of transducer gel and other substances. CAUTION : Do not operate the unit if it is damp or wet because of condensation or spills. Avoid using the equipment immediately after moving it from a cold environment to a warm, humid location. CAUTION - The equipment conforms to Class A according to IEC/EN 60601-1(Safety of Electric Medical Equipment) - This equipment conforms to Level B according to IEC/EN 60601-1-2(Electromagnetic Compatibility Requirements) CAUTION : Equipment containing primary batteries shall contain a warning to remove these batteries if Equipment is not likely to be used for some time. WARNING : EXPLOSION HAZARD - Do not use the F10 in a flammable atmosphere where concentrations of flammable anesthetics or other materials may ocuur. 5 Operator manual Rev.00 F10 Main Body (Rear View) 4 Operator manual Rev.00 F10 Section 2. F10 2.1 F10 F10 is a pocket-sized fetal doppler that measures the fetal heart rate and outputs the fetal heart sound through a built-in speaker. Measuring the fetal heart rate(FHR) gives an indication of fetal well-being. 2.2 Configuration - F10 Main Body (1EA) - Ultrasound Gel (1EA) - Carrying Case (1EA) - 1.5V Battery (2EA) - User Manual (1EA) 2.3 Composition Main Body (Front, Top and Left side View) Power and Volume Switch Ear Phone Jack Probe Holder LCD Window Speaker Battery Cover Waterproof Probe (IPX7) Groove Joint Sensor 7 Operator manual Rev.00 F10 When the input signal is not stable, outer shape of heart rhythm indicator will flicker. If the voltage level of battery is lower than the required level, the battery low message bat Lo will appear as shown in Figure. In this case, the unit will not functional correctly and the batteries should be replaced. If the user wants to use external speaker, connect the audio cable with audio connection on top of the F10 3.3 Simple Clinic Information Acceleration : The pattern restored after FHR increasing more than 15 bpm for more than 15 sec. from baseline. (Baseline : FHR value in the section of no pains) Deceleration : The pattern restored after FHR decreasing more than 15 bpm for more than 15 sec. from baseline. Normal FHR : The pattern that FHR is formed between 120 and 160. Reactive : The case that Acceleration happens more than 2 times for 10 minutes. (Healthy) Non-Reactive : The case that Acceleration happens less than 2 times for 10 minutes. Section 4. Maintenance and Cleaning To keep the device clean, apply alcohol on a soft cloth and wipe the body and the probe once a month. Do not use lacquer, thinner, ethylene, or an oxidizing agent. If you use material that is not approved, it may cause damage to the product. In this case, the product will not be guaranteed within the warranty period. Keep the probes clean from dust or grime. Wipe the cable with a damp, and with clinical alcohol once a week. Do not immerse the main body or the probe in any liquid or detergent. Keep the main unit and the probe away from any liquid. 6 Operator manual Rev.00 F10 Section 3. How to use your F10 ? 3.1 Operational Requirements F10 has to be used under surrounding temperature of 10 ~ 40 and humidity of 30% ~ 8%. Handle with care. Avoid dust or flammable materials. Make sure the batteries are inserted correctly. When detaching the probe from the main body, slide the probe upwards to prevent damage. 3.2 How to use ? Turn the power and volume switch counterclockwise to turn the device on and adjust the volume level. Apply a liberal amount of ultrasound gel to the face of transducer (end of the probe). Place the transducer directly against the abdomen, just above the point where the pelvic bones meet (in early pregnancy). Search for the fetal heart by slowly moving the probe around until the fetal heart sounds are heard. Search for the position which can get the clearest heart sound. When the input signal is good and stable, FHR will appear the screen and heart rhythm indicator will flash as shown in figure. Battery Low FHR Heart Rhythm F10 Ultrasound Doppler System 9 Operator manual Rev.00 F10 Product Guarantee Thank you for purchasing F10. This product is manufactured and has passed through strict quality control and inspection. Compensation standard concerning repair, replacement, refund of the product complies with Consumer protection law 8 Operator manual Rev.00 F10 General Information F10 is classified as listed below; - Type-BF. - Internal powered equipment according to IEC/EN 60601-1 - This equipment conforms to Level B according to IEC/EN 60601-1-2 Turn the power off after use. If you do not turn the power switch off, 1 minute later, the sound will be muted automatically. In this case, a single beep sound will be heard. 5 minutes later, the system will go to sleep mode. In this case two beep sounds will be heard. The display will be turned off. In this mode power very little power is consumed.If you want to wake up the device from sleep mode, first of all, turn the power off and then 1 second later turn the switch on by turning the switch counterclockwise. 1.5V2(AA Type) Batteries are used for the system power. Do not use any other type of battery. Use of the wrong battery type may damage the equipment. Federal law restricts this device to sale by or on the order of a physician. Do not open the device cover or disassemble the device. Refer servicing to qualified personnel of Mediana Co., Ltd. Definition of Symbols This symbol identifies a safety note. Be sure to understand the function of this control before using it. Control function is described in the operation manual(IEC60601-1) Type BF Equipment(IEC60601-1) IPX7 : 1meter of water for up to 30minutes(IEC60529) Model Name : F10 Approval No. : Approval Date : Serial No. : Warranty Period : 1 Year Date of Purchase : Customer Hospital : Address : Name : Telephone : Sales Agency : Manufacturer : Mediana Co., Ltd. 11 Operator manual Rev.00 F10 Specifications Acoustic Ouput Terms and Definitions 10 Operator manual Rev.00 F10 Specifications Specifications - Ultrasound Center Frequency : 2MHz - Intensity : <10mW/cm2 - Sensitivity : 10~12 Weeks Onward - Heart Rate Counting Range : 50~240bpm - FHR Accuracy : 2% of range - Battery Type : 1.5V2(LR6 battery / AA Type) - Power consumption : 3VA, maximum - Battery Life : About 360min (Continuously use) - PC Interface : Sound Card (using by BCM220 S/W) - Waterproof Probe : IPX7 Physical - Main Body : (L)75128(D)26 - Probe : (L)25(H)131(D)25 - Weight(Main Body and Probe) : 200g (with batteries) Environmental - Operating Temperature : 10(50) to 40(104) - Operating Humidity : 30% ~ 85% non-condensing - Operating Atmospheric Pressure : 70~ 106 - Storage Temperature : -10(14) to 60(131) - Storage Humidity : 20% ~ 95% non-condensing - Storage Atmospheric Pressure : 70~ 106 13 Operator manual Rev.00 F10 Specifications Compliance 12 Operator manual Rev.00 F10 Specifications Acoustic Ouput Table This table indicates the acoustic output for the systzem and transducer combinations with a thermal index or mechanical index equal to or greater than one. This table is organized by transducer model and imaging mode. 15 Operator manual Rev.00 F10 14 Operator manual Rev.00 F10 Manufactures Declaration WARNING : For best product performance and measurement accuracy, use only accessories supplied or recommended by Mediana. Use accessories according to the manufacturers directions for use and your facilitys standards. The use of accessories, transducers, and cables other than those specified may result in increased emission and/or decreased immunity of the FM20. The F10 is intended for use in the electromagnetic environment specified below. The customer or user of the F10 should assure that it is used in such an environment.