Distillation Column Lab Report
Distillation Column Lab Report
In this section, we have done two experiments; the first one was the experiment of
determining the column pressure drops and second was the experiment of determining the
composition of mixture of toluene-methylcyclohexane using refractometer. In determining the
column pressure drops, we also managed to determine the boil-up rate of the mixture and
observed the foaming conditions over the trays. In the second experiment, we did also find the
refractive index, mass, mole fraction and the volume of components in the mixture of toluenemethylcyclohexane. The equipments and apparatus needed in the first experiment were a
continuous distillation column, measuring cylinder, power supply, and stopwatch. While the
experiment of determining the mixture compositions required a refractometer.
Method applied for the first experiment was no different from batch distillation in
industry. The distillation operated at total reflux which means there was no feed or top product or
bottom product, since the entire formed vapor will after condensation, return to the column.
Setting the power at several different intensities, we were able to make comparison of the boil-up
rate, the pressure drops and the degree of foaming for every different power supplied. The
experiment of determining the mixture compositions was rather simple; the sample was collected
and inserted into the refractometer and the refractive index was recorded. Using the data given,
we were able to determine the mole fraction of each component, mass and volume as well. After
all the calculations have been made, the graph was plotted.
Based on the graph plotted, we were able to observe the relationship for the boil-up rate
and the pressure drops in the column for the first experiment and the relationship between the
refractive index and the compositions of components.
INTRODUCTION
Distillation is defined as a process in which a liquid or vapour mixture of two or more
substances is separated into its component fractions of desired purity, by the application and
removal of heat. Distillation is based on the fact that the vapor of a boiling mixture will be richer
in the components that have lower boiling points, therefore when this vapor is cooled and
condensed, the condensate will contain more volatile components. At the same time, the original
mixture will contain more of the less volatile material. There are many types of distillation
column, each designed to perform specific types of separation, and each differs in terms of
complexity.
1.) Batch column: in batch operation, the feed to the column is introduced batch-wise. That is,
the column is charge with a `batch` and then the distillation process is carried out. When
the desired task is achieved, a next batch of feed is introduced.
2.) Continuous column: in contrast, continuous columns process a continuous feed stream. No
interruptions occur unless there is a problem with the column or surrounding process unit.
They are capable of handling high throughputs and are the more common of the two types,
trays column and packed column.
Distillation columns are made up of several components, each of which is used either to
transfer heat energy or enhance material transfer. A typical distillation contains several
major components:
1.)
2.)
3.)
4.)
5.)
feed and this is introduced usually somewhere near the middle of the column to a tray known as
the feed tray. The feed tray divides the column into a top (enriching) section and bottom
(stripping) section. The feed flows down the column where it is collected at the bottom in there
boiler. Heat is supplied to the reboiler to generate vapor. The source of heat input can be any
suitable fluid, although in most chemical plants this is normally stream. In vapor raised in there
boiler is re-introduced into the unit at the bottom of the column. The liquid removed from their
boiler is known as the bottom product.
The vapor moves up the column, and as it exits the top of the unit, it is cooled by a
condenser. The condensed liquid is stored in a holding vessel known as the reflux drum. Some
of this liquid is recycled back to the top of the column and this is called the reflux. The
condensed liquid that is removed from the system is known as the distillate or top product. Thus,
there are internal flows of vapor and liquid within the column as well as external flows of feeds
and product streams, into and out of the column.
OBJECTIVES
The objectives of this experiment are:
1. To determine the pressure drop of the distillation column for various boil-up rates, to
observe the degree of forming on trays for each power increment,
2. To plot the curve relating pressure drop and boil-up rates,
3. To determine the refractive index for unknown concentration of methylcyclohexane and
toluene from the distillation column for each power increment
THEORY
Distillation is a process of separating two or more miscible liquids by taking advantage
of the boiling point differences between the liquids. To understand how distillation works
consider the mixture of toluene and methylcyclohexane for this distillation experiment. Heat is
added to the mixture of toluene and methylcyclohexane and eventually the most volatile
component (in this case methylcyclohexane) begins to vaporize.
As the methylcyclohexane vaporizes it takes with it molecules of toluene. The
methylcyclohexane-toluene vapor mixture is then condensed and evaporated again, giving a
higher mole fraction of methylcyclohexane in the vapor phase and a higher mole fraction
of toluene in the liquid phase.
This process of condensation and evaporation continues in stages up the column until the
methylcyclohexane rich vapor component is condensed and collected as tops product and the
water rich liquid is collected as bottoms product.
To understand distillation, first consider what happens upon heating a liquid. At any
temperature, some molecules of a liquid possess enough kinetic energy to escape into the
vapor phase (evaporation) and some of the molecules in the vapor phase return to the liquid
(condensation).
Equilibrium is set up, with molecules going back and forth between liquid and vapor. At
higher temperatures, more molecules possess enough kinetic energy to escape, which results in a
greater number of molecules being present in the vapor phase. If the liquid is placed into a closed
container with a pressure gauge attached, one can obtain a quantitative measure of the degree
of vaporization. This pressure is defined as the vapor pressure of the compound, and can be
measured at different temperatures.
MATERIALS
Methylcyclohexane-toluene
25 mol percent, 50 mol percent and 75 mol percent methylcyclohexane
APPARATUS
Continuous distillation column (UOP3CC)
100mL measuring cylinder
Stopwatch
Refractometer
PROCEDURES
General Start-Up Procedure
1. Electrical power to the control console is switched on. This is achieved by moving
the ELCB switch to the UP position. The LOW LEVEL lamp in the reboiler heater
section of the console is illuminated. The reboiler power, reflux timer, column
temperature and process temperature digital displays are also illuminated.
2. All the valves (V1 to V5) are ensured to be in the closed position.
3. Laboratory cold water supply is turned on. Flow control valve (V5) is opened to
give maximum flow into the condenser via flowmeter (F11). Any
leakages are
checked.
4. The manometer tube is filled until an equal level is visible about halfway up the
scale. Valves (V6 and V7) are closed.
5. Reboiler heater power is switched on at the console and power to the heater is
adjusted to 1.50 kW. Water in the reboiler began to heat up and this is observed by
6.
RESULTS
A. Using distillation column
Power (kW)
Collection
time (s)
120
37
22
5
9
0.5
0.75
1.0
1.25
1.50
Power (kW)
0.5
0.75
1.0
1.25
1.50
Boil-up rate
(L/s)
0.00075
0.0024
0.0041
0.018
0.01
Pressure drop
(cm H2O)
69
80
161
170
155
Degree of foaming on
trays
Gentle localized
Violently localized
Super violently localized
Super violently localized
Over whole tray
Refractive index
1.44172
1.45394
1.44584
1.45876
1.46849
Concentration of unknown
(toluene mol %)
0.01
0.01
0.02
0.02
B. Without using distillation column (finding refractive index from mixing of solution)
Sample
A
B
C
D
E
Refractive index
1.49612
1.47402
1.45526
1.43716
1.42383
20
40
60
80
100
Methylcyclohexane Percentage
10
120
DISCUSSION
In the experiment of determining the pressure drop of the mixture in the column, we were
not only determining the pressure drop alone, but also the boil-up rate and the observation of the
degree of foaming on each tray were recorded. To obtain the data, first thing we did was
controlling the power intensity of the boiler. The power controller was turned until a reading we
decided was obtained on the digital wattmeter. After that, 90 mL of the mixture were collected
and the times of collection were recorded. This procedure enables us to calculate its boil-up rate.
Then, we may take the reading of pressure drops by observing the manometer.
As the experiment went to the end, the pressure drops seem to increase as the power and
boil-up rate increased. However the last reading of pressure drop did not show the similar pattern
in contrast. This was due to the technical error; the sample of the mixture from the column has
overflowed into the manometer arms, caused the formation of two layers of fluid in the
manometer. This situation brought to decreasing pressure difference which violates the theory of
pressure drop increase with increasing boil-up rate. Note that the distillation practice was
operated at total reflux, meaning the entire formed vapor returned to the column after
condensation.
Meanwhile for the experiment of determining mixture compositions using refractometer,
we managed to obtain not only the compositions of the methylcyclohexane and toluene, but also
their refractive index. By only calculating the composition of methylcyclohexane, we would also
get the composition of toluene, since their composition made a total of 100 percent mixture. As
stated in the result, the refractive index recorded decreased with increasing mole fraction of
methylcyclohexane. This statement refers that as the mole fraction of toluene increased, the
refractive index increased as well in almost proportional manner.
11
CONCLUSION
The experiment of determining column pressure drop was done in order to achieve the
objectives of performing batch distillation and to determine the overall pressure drop. Besides,
we were able to observe the degree of foaming of mixture of toluene and methylcyclohexane on
each tray. It was seen that as we adjusted the power of boiler heater to be higher, the
corresponding boil-up rates were also increased. In spite of that, the pressure drops recorded for
various boil-up rates were also increased as the boil-up rates increased. This relationship was
also shown diagrammatically by plotting the graph of pressure drop against the boil-up rates.
From the graph, it can be seen clearly that boil-up rate increased as the pressure drop increased,
but not in proportional relation. The degree of foaming on trays also showed a trend of gentle to
a more violent condition as the boil-up rates increased. At the beginning, the boiled mixture was
gently localized. After some times, it was seen that the condition has altered to violently localize.
It was then followed by the condition of foaming gently over whole tray, foaming violently over
whole tray, and finally, we observed that there was an amount of liquid flooding in the column.
The second experiment, the experiment of determining mixture compositions was
generally done to determine the relationship between the mixture composition or concentration
or mole fraction with their refractive index. The refractive index can be read using equipment
called refractometer. Based on the result, it can be seen that as the concentration of
methylcyclohexane decreased, the refractive index increased. This relationship was also shown
diagrammatically by plotting the graph of refractive index at room temperature against the mole
fraction of methylcyclohexane. The graph clearly showed that the refractive index decreased as
increasing mole fraction of methylcyclohexane.
In short, the objectives of these experiments were achieved though there were errors
occurred during readings of pressure drop in experiment of determining the column pressure
drops were taken.
12
RECOMMENDATIONS
REFERENCES
Geankopolis, Christie John. Transport Processes and Separation Process Principles, 4th ed.
New Jersey: Prentice Hall, 2003
Laboratory Manual
http://en.wikipedia.org
http://www.engineeringtoolbox.com
13
APPENDICES
14