Pic Led
Pic Led
3GHz
Vratislav Michal OK2PTP
Lately many articles in scientific literature
deal with construction of an universal
frequency counter. But the authors mostly
think of frequency meter instead of
frequency counter. We usually need
something different than a measure
apparatus in practical use. Various
applications put to designer various claims.
Basic tendency of this development was to
fill up this free position with an easy, cheap
but qualitative simultaneous device, which
can work in wide spectrum of application
without bigger change in the electrical
circuit.
Technical parameters:
Frequency range:
10Hz 1.3GHz
Basic frequency range:
0 2MHz
0 20MHz
with frequency divider:
20 200MHz
20 1.3GHz
Resolution:
5(5 1/2) dgt.
Wide spectrum action with IF,
range, pulse counting.
As I said the apparatus was
developed with respect to
maximum flexibility and its
chance of applying is from an
easy meter by way of scale to
AM FM tuner, even to scale to
radioamateur transceivers with
many bands and atypical I.F.,
with a possibility to switch way
of counting and auto range.
Configuration can be set with
DIP switch, in menu or by
external logical circuits.
General description:
After resetting the apparatus
rings three tones and says us that
the resetting was made, internal
EEPROM memory is read and
the DIP switches are read.
According to this configuration
all the next actions of the counter
will be controlled (besides some
exceptions).
Frequency measuring:
The counter sets itself to this
mode after the beginning of
configuration. There are some
functions in this mode: by
pressing switch SW2 measuring
stops and the last actual
frequency DATA HOLD will
be blinking on the display. We
can change conversion of I.F.
shift by pressing switch SW3 and
in addition it enables a bigger
resolution. Push switch SW1 to
return.
The next functions are very
important for installation of
frequency counter to any
application. You can set one
fixed range with DIP2,3. DIP2 is
lower range and DIP3 is higher
range. This setting switches off
auto range and is absolute after
resetting.
You can set type of external
frequency divider (decimal point)
with DIP4. If the DIP4 is not
switched, pin RB0 is activated as
input pin and logical level on this
pin you can set decimal point: for
L frequency is displayed 1:1
(without external frequency
divider) in kHz and for H is
displayed 1:1 only with external
frequency divider 1:100. For
divider 1:10 (SW TCVR )
DIP4 must be set. This setting is
absolute and logical level on
RB0 has no effect.
Pulse counter:
The counter can cross to pulse
counter mode by pressing switch
SW1. Maximum pulse frequency
is about 50kHz. This mode is
indicated on display by legend:
COUNT and it is thought as an
additional
function
for
application
as
laboratory
frequency counter and could find
exercise in work with logical
circuit, wire coiling etc. Function
DATA HOLD is implemented in
this mode (it has a similar use as
in frequency measuring) by
pressing SW2 and real time
display clear (SW3).
Setting mode:
The setting menu is open after
the third stroking of the switch
(SW1). It is indicated by legend
SET_F. If we dont push any
other switch, we can return to
frequency measure mode by the
next pressing SW1. As we are
supposed to use counter in two
(four)
decades,
two
I.F.
frequencies (for each range) must
be set. One for higher range and
one for lower range. If you push
SET_F SW2 in setting menu then
you can set IF frequency for
lower range and by pressing
SW3 for higher range. If switch
DIP2,3 (auto range) is not set and
we want to use counter in two
Tuner SW/WHF:
This application uses frequency
counter in four decades. E.g. 88108MHz and 550-1.6MHz. Set
IF 01070 (type) on lower range
and 00455 (type) on higher
range. Set off auto range (set
DIP3 for fixed higher range) and
mode PIN. . Then connect
decimal point controler pin and
pin for IF switch (across
resistance) and this connect to
band selector (SW=L, USW=H).
Wire connect description:
This frequency counter is divided
into two parts:
- Frequency counter
- Subvention circuits
The whole counter is controlled
by IO1 uPC PIC16C84 by
Microchip. This microcontroler
works with crystal 6.000MHz.
Except measuring it controls
processor display, switch, input
pins etc. As this microcontroler
has absence of free pin, a seril
communication protokol between
microcontroler and display was
chosen. Shift register IO3 74164
is used as serioparalel convector.
Component list:
R1,R2,R3
680R
R4,R14,R17,
R24,R21
R5,R6,R9,R10,
R11,R12,R13 1K
R7,R8,R16,
R22
150R
R15,R23
47R
R19
1M
R20
10K trimr.
R18
2K2 trimr
C1
0-30pF trimr
C2
30pF
C3,C4,C5,
2u2
C6,C7
47uF
C8,C11,C12,
C13,C14, C9
M1
C10
47Pf
D1,D2
LED
D3,D4
KA206
D5,D6
BAT46
T1-T6,T8
KC636
T7
KF245
IO1
PIC16C84(16F84)
IO2
MH74LS42
IO3
MH74LS164
IO4
SAB6456 (SDA4212,
U664)
IO5
MH74LS390
IO6
MH74LS132
S1- S5
SA56EWA.
DIP
4Xdip
Xtall
6,000MHz
I can send reprogramming
processor
for
the
parties
concerned in building (after
transmission) (for the charge of
postage) or SASE (envelope with
stamp). But after setting I can
send a new processor.
Vratislav Michal
Bezruova 4
OLOMOUC 77200
CZECH REPUBLIC
tel.: +420732166550