600 KVA DG Set Brochure.195223435
600 KVA DG Set Brochure.195223435
Page
1. Introduction
2. Product Specifications
3. Product Features
5-8
9
1. INTRODUCTION
Kirloskar Engines - The driving force
n
The brand 'Kirloskar', a rich engineering heritage of over 120 years.
n
Kirloskar Oil Engines Ltd is a part of India's premier engineering Kirloskar group,
founded in 1946.
n
India's largest & leading manufacturer of the widest range of Diesel Engines and
applications (3 hp to 11000 hp).
n
Kirloskar engines are available in both air cooled & liquid cooled versions.
n
Annual engine volumes exceeding 2,30,000.
n
Active population of over two million engines worldwide
n
Sales exceeding Rs. 2100 cr.
n
Dominant market presence in power generation, construction, earthmoving & material
handling equipments.
n
Our journey towards excellence :
n
ISO/TS 16949 since 2007 by ABS QE, Inc.
n
ISO 14001 certification for EMS systems, since 1999 by TUV NORD.
n
ISO 9001 certification for QMS since 1992 by ABS QE, Inc.
n
OHSAS 18001:2007 certification for Health, Safety & Environment since
2009 by PUV NORD
n
Awarded as 'best energy efficient unit ' by Govt of Maharashtra for Pune
& Nashik plants.
n
CII Exim Business Excellence Award for Strong Commitment to Excel.
Kirloskar Green Gensets
n
Kirloskar Green' Gensets are acknowledged market leaders in India with full range
from 5 kVA to 625 kVA and 1.6 MW to 5.1 MW.
n
More than 60,000 Gen-sets across the country provide stable and reliable power for the
Indian Telecom Network.
n
More than 15,000 Gen-sets deployed along the Indian Borders, supporting the Defence
Organizations.
n
Large number of Satisfied Customers from Manufacturing, Software, Construction,
Infrastructure & Service sectors in 320 kVA to 625 kVA range.
Page-1
2. PRODUCT SPECIFICATIONS
DV 12 powered Gen-set Technical specifications
GENSET PARAMETERS
Genset Model
KG600WS3
KG625WS3
KVA Rating
kVA
600
625
KW Rating
kW
480
500
Voltage
415
415
Frequency
Hz
50
50
0.8
0.8
6670
6670
Phase
Power factor
Overall Dimensions of gen-set
Length
mm
Width
mm
2000
2000
Height
mm
2750*
2750*
mm
3450
3450
Kg
7500
7500
Kg
8450
8450
RPM
1500
1500
Electric (24V)
Electric (24V)
10
10
Ltr/Hr
91.9**
96**
0.12^
0.12^
Hrs
500
500
95.7
95.7
<=75dba
<=75dba
42.86
42.86
88
88
Rated speed
Method of Starting
Overload capability (for 1hr in 12 hrs operation)
Fuel consumption at 75% load
Lube Oil Consumption % of fuel consumption
Lube oil change period
Alternator efficiency at 75% load
DG set Noise level at 1Mtr (with canopy)
Overall thermal effiency of engines/break thermal
effiency of engines at 100%load
Mechanical effiency 100% load
dBA
Note :
*
Height of genset including silencer
** Considering Specific gravity of diesel as 0.845(+5% tolerance applicable as per ISO 3046) for well run
Genset
In view of continuous product up-gradation, above specifications are subject to change without prior notice
Page-2
3. PRODUCT FEATURES
Engine Features
n
Four valve technology & Central injection system makes 'DV12 the most fuel
efficient engine in its class.
n
Kirloskar 'DV12 engine is compliant to future emission norms of EU stage 2 level.
n
Kirloskar 'DV12 engine can operate on 100 % bio-diesel giving 100 % power &
lower emissions.
n
Lower lub oil sump capacity as compared to others, lower maintenance cost.
n
Enhanced oil change period of 500 Hrs.
n
Coolant change after 4000 Hrs.
n
Light weight & strong crankshaft material, gives better strength and increases
the power train peak cylinder capability by 20 %.
n
Gear cover & bell housing is a single piece design resulting in less leakage points &
less torsional vibration.
n
'Belly Mounted' engine design reduces the vibrations and thus improves the reliability of
engine.
n
Most ideal for AMF application as well as for parallel operations.
n
Provision of 'Auto Idle run' during start & stop gives time reduces initial friction
losses improving life of engine & Turbo charger.
n
Indigenously developed fuel injection system, designed in collaboration with 'Bosch',
with two feed pump units.
n
'Double feed pump' increases tolerance for low level of fuel in fuel tank, resulting in
less chances of air locking.
n
Air to air CAC results in less exhaust temperature, hence less load on cooling system
thereby improving the reliability of engine.
n
Heavy duty Turbo charger, fully matched for varying load conditions.
n
Rugged design to meet toughest operating conditions.
Gen-set Features
n
Compact and aesthetically designed, CPCB approved canopy.
n
Excellent transient response for sudden loading.
n
State-of-art Engine and Gen-set monitoring system.
n
Safety control for low coolant level in radiator, as standard feature.
n
Engine health monitoring through internet and SMS to operator. (Optional)
Page-3
Gen-set Metering
Parameters
Phase/Line voltage
Line current
Frequency
Average Voltage
Average Current
Phase kW & Total kW
Kwh & PF
kVA / kVAr
Earth fault current
Engine Metering
Parameters
Oil Pressure
Engine coolant Temperature
Fuel Status
Engine speed
Oil Temperature (optional)
Canopy Temperature
Engine run Hours
Total starts
Battery condition monitoring
Electrical Safeties
(Along with Metering)
Genset Under/Over voltage
Battery Under/Over voltage
Under/Over frequency
Phase Failure
Phase sequence reverse
Over Current
Over kW
High Earth Current
Mains monitoring
Mechanical Safeties
(Along with Metering)
Under/Over speed
Low Lube oil pressure
High Lube oil Temperature (optional)
High engine coolant temperature
Charging Alternator fail
Low coolant level
Low fuel level
High canopy temperature
Start/Stop fail
n
State of the art Compact Microprocessor based fully configurable technology.
n
Integration of all engine and alternator parameters.
n
For ease of viewing, high performance graphical LCD and prominent display.
n
Event logging history (stores last 100 events with date time stamp and complete
KG 400 WS
Page-4
DV 12
DV 12 SR1
kW ( hp )
532.13(723)
552(750)
No.
12
V type
4 Stroke DI
23.88
130 150
TA
16.5:1
7.5
18.73
1-12-5-8-3-10-6-7-211-4-9
12
V type
4 Stroke DI
23.88
130 150
TA
16.5:1
7.5
18.73
1-12-5-8-3-10-6-7-211-4-9
45%
On request
2100
2100
Micron
Inline
16 1
7 0.248
HSD IS 1460
Spin on
5
Inline
16 1
7 0.268
HSD IS 1460
Spin on
5
KPa
100
100
Kpa
m
Kg/cm2
250
1
260
250
1
260
(g/Hp-hr)
(g/Hp-hr)
(g/Hp-hr)
150*
144*
143*
150*
144*
143*
Ltrs
mm
m/s
Kg/cm2
mm
Kg
Deg BTDC
mm
* Declared sfc for well run engine tested at standard conditions(+5% tolerance applicable as per ISO 3046)
(Contd)
Page-5
Ltr
Ltr
Ltr
K-Oil Super
Gear Pump
50
40
57
K-Oil Super
Gear Pump
50
40
57
Deg
15
15
bar
Micron
4-4.5
Spin on
12
4-4.5
Spin on
12
LPM
130
130
Hrs
500*
500*
LPM
Kg/cm2
Liquid cooled
700
1
Liquid cooled
700
1
Ltr
144 10 %
50:50
144 10 %
50:50
m3/min
596
600.6
m3/min
m3/min
49
645
53
653.1
Ltr
LPM
LPM
Kg/cm2
On request
On request
On request
On request
On request
On request
On request
On request
m3/min
On request
On request
Deg C
74-88
74-88
Deg C
104
104
(Contd)
Page-6
kW
kW
kW
kW
213.1
108.6
358.0
117.5
221.6
112.9
372.3
122.2
mm of H2O
Kpa
Dry
635*
310
Dry
635*
310
Deg C
75
75
mm of H2O (kpa)
kg/hr
Deg C
Residential grade
1175 (11.5)
3026
600
Residential grade
1175 (11.5)
3147.04
600
BSU
mm
127
127
Electronic :Integral
with Fip &
Isochronous capability
Yes
<10
Electronic :Integral
with Fip &
Isochronous capability
Yes
<10
<10
<10
sec
<5
<5
Optional
Optional
OHV
0.35
1 27 min BTDC/
11 27 min ABDC
24 43 min BBDC/
7 18 min BTDC
OHV
0.35
1 27 min BTDC/
11 27 min ABDC
24 43 min BBDC/
7 18 min BTDC
Sec
30
30
10% for 1 hr in
12 hrs of Operation
10% for 1 hr in
12 hrs of Operation
Type
Whether adjustable droop provided
Transient speed increase for
sudden 100% decrease of load
Transient speed decrease for
permissible sudden increase of load
Recovery time
Speed raise / lower from panel provided
VALVE MECHANISM
Type
Valve clearance at cold: Inlet / Exhaust
mm
Deg
Deg
* Do the maintenance of air cleaner element depends on Restriction indicator showing red band or 635 mm
of wg pressure whichever will be earlier
(Contd)
Page-7
In view of continuous product up-gradation, specifications given in Technical data sheet are subject to change without prior notice
Page-8
Parameter
Nox (g/kW Hr)
CO (g/kW Hr)
HC (g/kW Hr)
PM (g/kW Hr)
Smoke (in m-1)
Average Sound level at
1m with canopy (dBA)
CPCB Limits
9.2
3.5
1.3
0.3
0.7
KOEL: DV12
6.1
0.38
0.13
0.06
0.05
75
75
20
30
38
45
2400
1500
1200
900
n
Full rated
Customer Entitlements
Assistance
n
n
Assistance
n
Joint commissioning
n
2 years
n
Warranty
n
9 free
n
First fill
n
K-Cool
n
Training
Page-9
Service Offerings
: North Zone
n
Free service checks.
n
Authorized Kirloskar Service Dealers in your neighborhood to promptly respond to your service calls,
provide extensive after sales support including
operational, maintenance & repair contract.
Srinagar
Jammu
Kathua
Himachal Pradesh
n
Single window service for Genset & Customised AMC.
n
Fully implemented CRM module to provide proactive &
quick service response.
n
K-oil / K-cool super plus for product life extension.
n
Excellent product support through easy availability of
spare parts, product training, Re-conditioning and
warranty administration.
n
Easy and Quick delivery anywhere anytime.
: West Zone
: South Zone
Bhuj
hal
n ac
Aru desh
Pra
Itanagar
Siliguri
Madhya Pradesh
Ahmedabad
Bhopal
Jabalpur
Indore
Ankleshwar
Jamshedpur
Khandwa
Baroda
Surat
Jamnagar
Bhavnagar
Akola
Maharashtra
Orissa
Chandrpur
Jharsuguda
Latur
MUMBAI Thane
Chiplun
Kankavli
Bhubaneshwar
Angul
Balasore
Andhra
Pradesh
Pandharpur
PCMC ZA
Pune
Ratnagiri
Jajpur Road
A'Nagar
Panvel
Raigad
Barbil
Raygada
Raipur
Aurangabad
Bhiwandi
KOLKATTA
Sambalpur
Nagpur
Yavatmal
Aizwal
Mizoram
West Bengal
Rourkela
Chattisgarh
Amravati
Nashik
Silvassa
Johrat
Manipur
Imphal
Burdwan
Pakur
Gandhinagar
Nagaland
Assam
Meghalaya
Asansol
Ranchi
Guwahati
Barpeta
Jharkhand
Gujarat
Rajkot
n
Support systems like Mean Time to Restore, Engine
Down Order, First Pick Availability for maximum uptime
of Gensets.
A : Area Office - 13
Damtal Kulu
Mandi
Una
Punjab
Amritsar
Baddi
Jalandhar
Ferozpur
Shimla
Ludhiana
Uttaranchal
A
Chandigarh
Dehradun
Sangrur Yamuna
Bhatinda
Haridwar
nagar
Patiala
Karnal
Saharanpur
Sri Ganganagar
Panipat
Haldwani
Sirsa
Rohtak
Bijnor
Hissar
Haryana
DELHI
Rewari
Moradabad
A
Nepal
Ghaziabad
Uttar
Jhunjunu
Prad
Bikaner
Noida
esh
Gurgaon
Meerut
Jaipur Karauli
F'bad
Sitapur
Rajasthan
Aligarh
Bareilly
A
Bhiwadi
Gonda
Jaisalmer
Hardoi
Agra
Alwar
Ajmer
Shahjahanpur Lucknow
Muzaffarpur
Faizabad
Jodhpur
Hardoi A
Madhubani
Gorakhpur
Balotra
Kanpur
Sultanpur Mau
Patna Hajipur
Gwalior
Rajsamand
Bhilwara
Allahabad
Katihar
A
Barmer
Bihar
Varanasi
Udaipur
Jhansi
Kota
Bhagalpur
Badohi
Gaya
Dungarpur
Satna
Mehesana
Dhanbad
n
24/7 help line service for all our customers, offering
timely customer support to deal with inquiries.
n
Trained & experienced service team to provide
value-added support to the highest standards
ensuring customer satisfaction at all times.
: East Zone
Leh
Rajouri
Tripu
ra
Solapur
Satara
Kolhapur
Gulbarga
Kagal
Belgaum
Vishakhapattanam
Warangal
Secundrabad
Hyderabad
Rajamundri
Vijaywada
Karnataka
Goa
Cuddapah
Hubli
Nellore
Dharwad
Ananthapur
Kurnool
Hasan
Chittor
Mysore
Salem
Port Blair
Karur
Erode
Tirupur
Andaman
Islands
CHENNAI
Pondicherry
Dindigul
Calicut
Trichur
Ernakulam
Kochi
Lakshadweep
Bangalore
Kerala
Help Desk :
Call 1800 233 3344 (Toll-free from BSNL / MTNL)
020-6608 4608 (Other than BSNL / MTNL)
Email : koel.helpdesk@kirloskar.com
Tirupati
Udupi
Mangalore
Karaikkal
Thanjavur
Coimbatore
Tamilnadu
Idukki
Pallakad
Kottayam
Trivandrum
Trichy
Tirunelveli
Sivakashi
Madurai
Nicobar
Tuticorin
Nagarcoil
Islands
DEVAASHISH
Stamp of
Authorised
98101-15841,
30123124.
Representative
www.kirloskar.com
www.devaashish.in
PH: