Part Submission Warrant (PSW)
Part Submission Warrant (PSW)
Safety and/or Government Regulation Yes No Purchase order number 34481 Weight 0.1400
Checking aid No. NA Checking Aid Engineering Change Level AC01 Dated 10/1/2004
Materials Reporting
Yes No n/a
Has customer-required Substances of Concern information been reported?.
Submitted by IMDS or other customer format 34543911/4.01 (Node ID 85091873)
Yes No n/a
Are polymeric parts identified with appropriate ISO marking codes?
SUBMISSION RESULTS
The results for dimensional measurements material and functional tests appearance criteria statistical process package
These results meet all drawing and specification requirements: YES NO (If "NO" - Explanation Required)
Mold / Cavity / Production Process
DECLARATION
I affirm that the samples represented by this warrant are representative of our parts, which were made by a process that meets all
Production Part Approval Process Manual 4th Edition Requirements. I further affirm these samples were produced at the rate of 480/ 8 hours.
I also certyify that documented evidence of such compliance is on file and available for review. I have noted any deviations from this declaration below.
EXPLANATION/COMMENTS: This is a material change per DCS File Log #15251336, with supporting data as requested by
the customer.
Print Name Roosevelt Stewart Phone No. 616-990-1664 Fax No. 616-748-6909
The original copy of this document shall remain at the supplier' location Optional: customer tracking
July 1999 CFG-1001 while the part is active (see Glossary). number: # ______________
PROCESS FLOW DIAGRAM
GMX222 Cell Manual
15A - Move Components to Storage Area Moved Place within labeled storage areas
25A - Vacuum Load Resin into Dryer Correct Resin Loaded Resin in Hopper
25B - Load Steel onto Decoiler Per Start Up Instructions Orientation Per Operator Instructions
25C - Load Switches into Bowl Feeder Correct switches Alps VSPED3222
25D - Manual Load Switches into Tote Correct switches Alps VSPED3222
30A - Form Circuit Functionally correct Verified in subsequent processes GO/ NoGo
Connector height 0.8mm +/- 0.1mm
Switch terminal height 0.6mm +/- 0.1mm
@BCL@7C1482F5.xls 1
GMX222 Cell Manual
Orientation, stamping
35A - Feeder Loads Circuit into Mold Cavity retained in tool Orientation/retained prior to molding
Orientation, stamping
35B - Manual Load Circuit into Mold Cavity retained in tool Proper Orientation
35C - Mold Station 1/detach circuit Circuit Separated Circuit completely separated
45C - Part is manually detached from plastic web Runner detached 4 runners detached
Brass detached 1 brass flag detached
50A - Install 2 switches Switches Installed Fully seated Two switches installed
50B - Manual Install 2 switches Switches Installed Fully seated Two switches installed
55A - Install bulbs into part Bulbs Installed Fully seated Two bulbs installed
55B - Manual Install 2 bulbs Bulbs Installed Fully seated Two bulbs installed
58A - Bulbs burned in Bulbs burned in Light up bulbs both bulbs light up
60A - Part detached from Web Cut edges clean Max vestige <1mm
60B - Transfer part to Check Station Per Print Poke Yoke Program/ Auto Reject Go/ NoGo
65A - Manual Install 2 reflectors Reflector Installed Fully seated 2 Reflectors Installed
65B - Screw reflector into part Screws installed Fully seated 4 screws installed
65C - Transfer part to Electrical Check Per Print Poke Yoke Program/ Auto Reject Go/ NoGo
70B - Machine Performs Electrical Testing Circuit Separated Circuit completely separated
Both Bulbs Light Both bulbs light up/amp draw test
@BCL@7C1482F5.xls 2
GMX222 Cell Manual
Circuits Change State Switch Location Circuits change state 8 times GO/ NoGo
70D - If part is bad, mark and place in reject tote Issue written on part All bad parts logged
70E - Parts ejected by machine Failed any above test All bad parts ejected
Passed all above test All good parts sent to pack
Put into a temporary
70F - Good parts packed Proper Quantity in the Tote tote 36 parts
80A - Perform Quality Checks after part is Ref Quality Doc Sheet/Key Quality Ref Quality Doc Sheet/Key Quality
completely assembled Characteristics Characteristics
85A - Perform Visual Containment Ref Containment Log Sheet Performed Ref Containment Log Sheet
Ref Shipping
90A - Totes placed on skid
Instructions
Ref Shipping
90B - Parts Shipped
Instructions
@BCL@7C1482F5.xls 3
SUBMISSION EXCEPTION REPORTS
SUBMISSION EXCEPTION REPORT
RISK RATING SYSTEM
P = Probability of Occurance
441 E. Roosevelt Ave. Zeeland 49464 S = Seriousness of Failure
Ph:(616) 772-5959 Fax:(616) 772-6006 R = Risk Priority Number = P x S
RATING
NO. FAILURE DESCRIPTION ACTION RESPONSIBILITY VERIFICATION
P S R
Validation testing for GMX 222 covered by 044L, GMT 201, LX GH have the same
surrogate data from attached testing design consisting of incandescent bulb
1 NA NA NA NA results. Innotec and switch.