V B01B0006B-GB PDF
V B01B0006B-GB PDF
V B01B0006B-GB PDF
Total competence
in seamless hot rolled-steel tubes
and pipes with long-lasting presence
in powergen business and first class
technical customer service (TCS)
Global presence
thanks to an efficient distribution and
service network
A complete range
All tubular products required in highcapacity power stations are subjected
to critical operating stresses. High quality requirements are applied to the steel
tubes and pipes, which have to withstand operating temperatures up to
about 625 C (1155 F) and pressures up
to 320 bar (4650 psi) over the plant lifetime of several decades.
Vallourec produces all these tubular
products, such as combustion chamber
tubes, header pipes and line pipe for
main steam and reheater circuits, in a
complete size range from the smallest
dimension up to large heavy wall pipe in
all required steel grades. The material is
melted in Vallourec own steel works,
tailor made to the requirements, including the most sophisticated grades such
as T91/P91 (or X10CrMoVNb9-1), T92/
P92 (or X10CrWMoVNb9-2), VM12-SHC
and T24/P24 (7CrMoVTiB 10-10).
1,000,000
Outside
diameter D
mm
21.3
22
25
25.4
26.9
30
31.8
32
33.7
35
38
40
42.4
44.5
48.3
51
54
57
60.3
63.5
70
73
76.1
82.5
88.9
101.6
108
114.3
127
133
139.7
141.3
152.4
159
168.3
177.8
193.7
219.1
244.5
273
323.9
355.6
406.5
457
508
559
610
660
711
in.
0.840
0.866
0.985
1.000
1.060
1.185
1.250
1.260
1.330
1.378
1.500
1.575
1.670
1.750
1.900
2.010
2.125
2.245
2.374
2.500
2.760
2.875
3.000
3.250
3.500
4-000
4.250
4.500
5.000
5.240
5.500
5.563
6.000
6.250
6.625
7.000
7.625
8.625
9.625
10.750
12.750
14.000
16.000
18.000
20.000
22.000
24.000
26.000
28.000
Weight in kg/m
2
0.079
0.952
0.986
1.13
1.15
1.23
2.3
0.091
1.08
1.12
1.29
1.31
1.40
1.57
1.67
1.68
1.78
2.6
0.102
1.20
1.24
1.44
1.46
1.56
1.76
1.87
1.89
1.99
2.08
2.27
2.40
2.55
2.69
2.93
3.10
3.30
2.9
0.114
1.32
1.37
1.58
1.61
1.72
1.94
2.07
2.08
2.20
2.30
2.51
2.65
2.82
2.98
3.25
3.44
3.65
3.87
4.11
4.33
4.80
5.01
5.24
3.2
0.126
1.43
1.48
1.72
1.75
1.87
2.11
2.26
2.27
2.41
2.51
2.75
2.90
3.09
3.26
3.56
3.77
4.01
4.25
4.51
4.76
5.27
5.51
5.75
6.26
6.76
3.6
0.142
1.57
1.63
1.90
1.94
2.07
2.134
2.50
2.52
2.67
2.79
3.05
3.23
3.44
3.63
3.97
4.21
4.47
4.74
5.03
5.32
5.90
6.16
6.44
7.00
7.57
8.70
9.27
9.83
4
0.157
1.71
1.78
2.07
2.11
2.26
2.56
2.74
2.76
2.93
3.06
3.33
3.55
3.79
4.00
4.37
4.64
4.93
5.23
5.55
5.87
6.51
6.81
7.11
7.74
8.38
9.63
10.3
10.9
12.1
12.7
13.4
4.5
0.177
1.86
1.94
2.28
2.32
2.49
2.83
3.03
3.05
3.24
3.38
3.72
3.94
4.21
4.44
4.86
5.16
5.49
5.83
6.19
6.55
7.27
7.60
7.95
8.66
9.37
10.8
11.5
12.2
13.6
14.6
15.0
15.2
16.4
17.1
18.2
10,000,000
hours of creep testing
More than
500
5
0.197
2.01
2.10
2.47
2.52
2.70
3.08
3.30
3.33
3.54
3.70
4.07
4.32
4.61
4.87
5.34
5.67
6.04
6.41
6.82
7.21
8.01
8.38
8.77
9.56
10.3
11.9
12.7
13.5
15.0
15.8
16.6
16.8
18.2
19.0
20.1
21.3
D = Outside diameter
5.6
0.220
6.3
0.248
2.68
2.73
2.94
3.37
3.62
3.65
3.88
4.06
4.47
4.75
5.08
5.37
5.90
6.27
6.68
7.10
7.55
8.00
8.89
9.31
9.74
10.6
11.5
13.3
14.1
15.0
16.8
17.6
18.5
18.7
20.3
21.2
22.5
23.8
26.0
2.91
2.97
3.20
3.68
3.96
3.99
4.26
4.46
4.93
5.24
5.61
5.94
6.53
6.94
7.41
7.88
8.39
8.89
9.90
10.4
10.8
11.8
12.8
14.8
15.8
16.8
18.8
19.7
20.7
21.0
22.7
23.7
25.2
26.6
29.1
33.1
37.0
41.4
7.1
0.280
8
0.315
3.47
4.01
4.32
4.36
4.66
4.89
5.41
5.76
6.18
6.55
7.21
7.69
8.21
8.74
9.32
9.88
11.0
11.5
12.1
13.2
14.3
16.5
17.7
18.8
21.0
22.0
23.2
23.5
25.4
26.6
28.2
29.9
32.7
37.1
41.6
46.6
55.5
3.73
4.34
4.70
4.74
5.07
5.33
5.92
6.31
6.79
7.20
7.95
8.48
9.08
9.67
10.3
10.9
12.2
12.8
13.4
14.7
16.0
18.5
19.7
21.0
23.5
24.7
26.0
26.3
28.5
29.8
31.6
33.5
36.6
41.6
46.7
52.3
62.3
68.6
8.8
0.346
5.40
5.69
6.34
6.77
7.29
7.75
8.75
9.16
9.81
10.5
11.2
11.9
13.3
13.9
14.6
16.0
17.4
20.1
21.5
22.9
25.7
27.0
28.4
28.8
31.2
32.6
34.6
36.7
40.1
45.6
51.2
57.3
68.4
75.3
86.3
10
0.394
6.91
7.40
7.99
8.51
9.45
10.1
10.9
11.6
12.4
13.2
14.8
15.5
16.3
17.9
19.5
22.6
24.2
25.7
28.9
30.3
32.0
32.4
35.1
36.7
39.1
41.4
45.3
51.6
57.8
64.9
77.4
85.2
97.8
110
11
0.433
12.5
0.492
14.2
0.559
9.09
10.1
10.9
11.7
12.5
13.4
14.2
16.0
16.8
17.7
19.4
21.1
24.6
26.3
28.0
31.5
33.1
34.9
35.3
38.4
40.1
42.7
45.2
49.6
56.5
63.3
71.1
84.9
93.5
107
121
135
9.86
11.0
11.9
12.8
13.7
14.7
15.7
17.7
18.7
19.6
21.6
23.6
27.5
29.4
31.4
35.3
37.1
39.2
39.7
43.1
45.2
48.0
51.0
55.9
63.7
71.5
80.3
96.0
106
121
137
153
168
184
13.9
15.0
16.1
17.3
19.5
20.6
21.7
23.9
26.2
30.6
32.8
35.1
39.5
41.6
43.9
44.5
48.4
50.7
54.0
57.3
62.9
71.8
80.8
90.6
108
120
137
155
173
191
209
16
0.630
17.5
0.689
20
0.787
22.2
0.874
25
0.984
28
1.102
30
1.181
32
1.260
36
1.417
40
1.575
45
1.575
50
1.575
55
1.575
60
1.575
65
1.575
70
1.575
80
1.575
90
1.575
100
3,937
325
381
481
544
644
744
844
945
1046
1144
1245
519
590
702
815
928
1041
1154
1265
1378
552
630
756
880
1006
1132
1258
1381
1507
Tolerance range
according to
EN 10216-2
+/ 0.4 mm
+/ 12.5 %
+/ 20.0 %
+/ 15.0 %
+/ 10.0 %
17.5
18.7
21.3
22.5
23.7
26.2
28.8
33.8
36.3
38.8
42.8
46.2
48.8
49.4
53.8
56.4
60.1
63.8
70.1
80.1
90.2
101
121
134
154
174
194
214
234
22.7
24.0
25.3
28.1
30.8
36.3
39.1
41.8
47.3
49.8
52.7
53.4
58.2
61.1
65.1
69.2
76.0
87.0
98.0
110
132
146
168
190
212
234
256
27.7
30.8
34.4
40.2
43.4
46.5
52.8
55.7
59.0
59.8
65.3
68.6
73.1
77.8
85.7
98.2
111
125
150
166
191
216
241
266
291
316
33.0
36.5
43.4
47.0
50.4
57.4
60.7
64.3
65.2
71.3
74.9
80.0
85.2
93.9
108
122
137
165
183
210
238
266
294
322
349
39.4
47.2
51.2
55.1
62.9
66.6
70.7
71.7
78.5
82.6
88.3
94.2
104
120
135
153
184
204
235
266
298
329
361
392
423
50.8
55.2
59.6
68.4
72.5
77.3
78.2
85.9
90.5
96.9
103
114
132
149
169
204
226
261
296
331
367
402
436
472
57.5
62.4
71.8
76.2
81.2
82.3
90.6
95.4
102
109
121
140
159
180
217
241
278
316
354
391
429
466
504
64.9
75.0
79.7
85.0
86.3
95.0
100
108
115
128
148
168
190
230
255
295
335
376
416
456
496
536
80.8
86.1
92.1
93.5
103
109
117
126
140
163
185
210
256
284
329
374
419
464
510
554
599
91.7
98.4
99.9
111
117
127
136
152
177
202
230
280
311
361
411
462
512
562
612
662
119
127
137
147
165
193
221
253
310
345
401
457
514
570
627
683
739
146
158
177
209
240
275
338
377
439
502
565
628
691
752
815
167
188
223
257
296
365
408
477
545
614
684
753
821
890
198
235
273
315
390
437
513
587
663
738
814
888
963
247
288
333
415
466
547
628
710
792
874
954
1036
257
301
350
438
493
581
668
756
844
932
1019
1107
Tolerance on
mm
D 219.1
1 % or 0.5 mm
D > 219.1
> 0.025
> 0.050
0.050
0.10
> 0.10
15 %
12.5 %
For outside diameters D 355.6 mm it is permitted to exceed the upper wall thickness locally by a further 5 % of the wall thickness T
10 %a
min
mm
in. 1.90
D
mm
21.3
2.03
2.16
2.29
2.41
2.54
2.67
3.05
3.43
3.81
4.19
4.57
5.08
5.59
6.10
6.60
7.11
7.62
8.13
in.
0.840
0.075
0.080
0.085
0.090
0.095
0.100
0.105
0.120
0.135
0.150
0.165
0.180
0.200
0.220
0.240
0.260
0.280
0.300
0.320
0.70
0.75
0.79
0.83
0.87
0.91
0.94
1.03
1.13
1.20
1.29
1.37
26.7
1.050
0.90
0.96
1.02
1.07
1.12
1.17
1.22
1.34
1.48
1.58
1.71
1.83
1.97
2.11
30.16
1.190
1.16
1.22
1.28
1.34
1.40
1.54
1.70
1.83
1.98
2.12
2.29
2.46
2.62
2.77
31.8
1.250
1.23
1.30
1.36
1.42
1.49
1.63
1.81
1.95
2.11
2.26
2.44
2.63
2.81
2.97
3.12
33.4
1.315
1.30
1.37
1.43
1.50
1.57
1.72
1.91
2.06
2.23
2.40
2.59
2.79
2.99
3.16
3.33
38.1
1.500
1.49
1.58
1.65
1.74
1.82
1.99
2.21
2.39
2.60
2.79
3.03
3.28
3.51
3.73
3.95
4.15
4.34
42.2
1.660
1.67
1.76
1.85
1.94
2.03
2.23
2.48
2.68
2.91
3.16
3.41
3.70
3.97
4.23
4.48
4.73
4.96
42.4
1.670
1.67
1.77
1.86
1.95
2.04
2.24
2.49
2.69
2.93
3.16
3.43
3.72
3.99
4.25
4.51
4.75
4.99
44.45
1.750
1.76
1.86
1.95
2.05
2.15
2.36
2.62
2.84
3.09
3.33
3.62
3.93
4.22
4.50
4.78
5.04
5.29
48.3
1.900
1.92
2.03
2.13
2.24
2.35
2.58
2.87
3.11
3.39
3.66
3.98
4.32
4.66
4.97
5.28
5.58
5.87
50.8
2.000
2.03
2.14
2.25
2.36
2.48
2.72
3.04
3.29
3.58
3.87
4.22
4.58
4.94
5.27
5.61
5.93
6.24
54
2.125
2.12
2.29
2.40
2.52
2.64
2.91
3.24
3.51
3.83
4.14
4.51
4.91
5.29
5.66
6.02
6.38
6.72
57.15
2.250
2.29
2.43
2.55
2.68
2.81
3.09
3.45
3.74
4.08
4.41
4.81
5.23
5.65
6.04
6.44
6.82
7.19
60.3
2.375
2.69
2.83
2.97
3.27
3.65
3.96
4.32
4.68
5.10
5.56
6.00
6.43
6.85
7.26
7.66
63.5
2.500
2.84
2.99
3.14
3.46
3.86
4.18
4.57
4.95
5.40
5.89
6.36
6.81
7.27
7.71
8.14
69.85
2.750
3.14
3.30
3.47
3.82
4.27
4.63
5.06
5.49
5.99
6.54
7.07
7.58
8.10
8.60
9.09
73
2.874
3.29
3.46
3.63
4.00
4.47
4.86
5.31
5.75
6.29
6.86
7.42
7.97
8.51
9.04
76.2
3.000
3.44
3.62
3.79
4.19
4.68
5.08
5.56
6.02
6.59
7.19
7.78
8.35
8.93
9.49
82.55
3.250
4.12
4.68
5.23
5.73
6.27
6.80
7.35
8.02
8.69
88.9
3.500
4.45
5.06
5.66
6.20
6.78
7.36
7.96
8.70
9.42
95.25
3.750
4.78
5.43
6.08
6.67
7.29
7.92
8.57
101.6
4.000
6.50
7.13
7.81
8.48
9.18
114.3
4.500
7.34
8.05
8.82
127
5.000
8.19
8.99
9.85
133.35 5.250
8.61
9.45
139.7
5.500
9.04
9.92
141.3
5.630
9.14
152.4
9.97
10.8
13.0
11.2
14.1
12.2
10.2
10.9
11.7
15.3
13.2
10.0
10.9
11.7
12.5
16.4
14.2
10.4
11.4
12.3
13.3
14.2
18.7
16.1
10.7
11.6
12.7
13.8
14.8
15.9
21.0
18.0
10.4
11.3
12.2
13.4
14.5
15.6
16.8
22.2
19.0
10.9
11.8
12.8
14.0
15.3
16.4
17.6
23.3
20.0
11.0
12.0
13.0
14.2
15.4
16.6
17.8
23.6
20.2
6.000
12.0
13.0
14.1
15.5
16.8
18.1
19.5
25.8
22.1
159
6.260
12.4
13.5
14.7
16.1
17.5
18.8
20.2
26.8
22.9
168.3
6.625
13.2
14.3
15.6
17.1
18.5
20.0
21.5
28.5
24.4
177.8
7.000
14.0
15.2
16.5
18.1
19.6
21.2
22.7
30.3
25.8
D = Outside diameter
10.0
Vallourec
9.58
9.37
9.33
10.1
9.56
10.0
mm
in.
mm
in.
mm
in.
D 76.2
D3
0.8 +0.4
1/32 +1/64
0.4
0.016
D > 76.2
D>3
according to standards
8.64
9.14
9.65
10.16
10.67
11.18
11.68
12.19
12.70
13.49
14.30
15.09
16.51
17.78
19.05
20.32
21.59
22.86
24.13
25.40
27.94
0.340
0.360
0.380
0.400
0.420
0.440
0.460
0.480
0.500
0.531
0.563
0.594
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.100
Tolerances on
wall thickness
0%
+ 35 %
0%
+ 33 %
4.53
5.18
0%
+ 28 %
5.21
5.42
5.62
5.54
5.76
5.98
6.16
6.36
6.55
6.15
6.41
6.67
6.87
7.10
7.33
6.54
6.83
7.11
7.33
7.59
7.84
8.07
8.30
8.52
7.05
7.37
7.68
7.92
8.21
8.49
8.75
9.01
9.26
7.55
7.90
8.24
8.51
8.82
9.13
9.42
9.71
9.99
8.05
8.42
8.79
9.09
8.56
8.96
9.36
9.68
9.57
9.44
9.77
0%
+ 24 %
8.83
0%
+ 22 %
9.62
10.4
10.8
10.1
10.4
10.7
11.2
11.6
12.0
10.1
10.4
10.8
11.1
11.5
12.0
12.4
12.9
0%
+ 20 %
10.0
10.5
10.9
11.3
11.7
12.1
12.5
12.9
13.5
14.1
14.6
15.5
16.3
10.1
10.6
11.0
11.4
11.9
12.4
12.8
13.2
13.7
14.3
14.9
15.5
16.5
17.3
10.6
11.1
11.6
12.0
12.5
13.0
13.5
13.9
14.4
15.1
15.7
16.4
17.5
18.3
11.8
12.4
13.0
13.6
14.1
14.7
15.2
15.8
16.3
17.1
17.8
18.6
19.8
20.9
21.8
22.7
23.6
12.9
13.5
14.2
14.8
15.4
16.0
16.6
17.2
17.8
18.7
19.6
20.4
21.8
23.0
24.1
25.2
26.1
13.9
14.6
15.3
16.0
16.7
17.4
18.0
18.7
19.3
20.3
21.3
22.2
23.8
25.1
26.4
27.6
28.7
14.9
15.7
16.5
17.2
18.0
18.7
19.4
20.2
20.9
21.9
23.0
24.0
25.8
27.3
28.7
30.0
31.3
17.0
17.9
18.8
19.6
20.5
21.4
22.2
23.0
23.9
25.1
26.4
27.6
29.7
31.5
33.2
34.8
36.4
37.9
39.4
40.8
19.1
20.1
21.1
22.1
23.1
24.0
25.0
26.0
26.9
28.3
29.8
31.2
33.6
35.7
37.8
39.7
41.6
43.4
45.2
46.9
20.1
21.2
22.2
23.3
24.4
25.4
26.4
27.4
28.4
30.0
31.5
33.0
35.6
37.9
40.0
42.1
44.2
46.2
48.1
49.9
21.1
22.3
23.4
24.5
25.6
26.7
27.8
28.9
30.0
31.6
33.2
34.8
37.6
40.0
42.3
44.6
46.8
48.9
51.0
53.0
56.7
21.4
22.5
23.7
24.8
26.0
27.1
28.2
29.3
30.3
32.0
33.7
35.3
38.1
40.5
42.9
45.2
47.4
49.6
51.7
53.7
57.6
23.4
24.6
25.9
27.1
28.4
29.6
30.8
32.0
33.2
35.1
36.9
38.7
41.9
44.6
47.3
49.8
52.4
54.8
57.2
59.5
64.0
24.3
25.6
26.9
28.2
29.5
30.8
32.1
33.3
34.6
36.5
38.4
40.3
43.6
46.5
49.3
52.0
54.7
57.2
59.8
62.2
66.9
25.8
27.2
28.6
30.0
31.4
32.8
34.1
35.5
36.8
38.9
41.0
43.0
46.5
49.6
52.6
55.6
58.4
61.3
64.0
66.7
71.8
27.4
28.8
30.3
31.8
33.3
34.8
36.2
37.7
39.1
41.3
43.5
45.7
49.5
52.8
56.0
59.2
62.3
65.4
68.3
71.2
76.8
ASTM requirements
mm
in.
Hot-finished
2.79
0.110
0 + 35 %
Vallourec
Cold-drawn
Hot-finished*
0 + 35 %
(0 + 40 % 0.095 in.)
> 2.79 3.8
0 + 35 %
0 + 33 %
0 + 28 %
> 10.1
> 0.400
0 + 28 %
D 38.1 (1")
0 + 20 %
0 + 28 %
D 38.1 (1")
0 + 22 %
0 + 22 %
0 + 24 %
0 + 20 %
1300/51.2
1220/48.0
80 mm
3.15 in.
1140/44.0
60 mm
2.36 in.
40 mm
1.57 in.
1180/42.4
Lm
1040/40.9
1010/39.8
980/38.6
950/37.4
5m
ax
.5
5m
/11
.4.
ft.
/14
/18
ft.
5m
.8
.5.
.1
5m
ft.
/31
ft.
/31
.9
ft.
27
5m
.6
ft.
/24
.1
5m
m/
.9.
.1
660/26.0
.9.
.7.
8.5
ax
700/27.6
ax
ax
ax
ft.
.3.
Lm
ax
Lm
Lm
800/31.5
Lm
10 mm
0.39 in.
850/33.5
Lm
20 mm
0.79 in.
Lm
900/35.4
25 mm
0.98 in.
ax
30 mm
1.18 in.
600/23.6
570/22.5
550/21.7
500/19.7
450/19.7
430/16.9
400/15.8
5 mm
0.20 in.
350/13.8
300/11.8
250/9.8
220/8.7
10
20 30 40 50 60 70 80 90 100
0.39 0.79 1.18 1.58 1.97 2.36 2.76 3.15 3.54 3.94
150
5.91
200
7.87
250
9.84
270
10.64
Standard programm
Machined tubes
or
+ 4 mm
0
0.03
whichever
is the
greater
20 %
12.5 %
> 0.12
10 %a
For outside diameters D 355.6 mm it is permitted to exceed the upper wall thickness locally by a further 5 % of the wall thickness T
or
+ 4 mm
0
whichever
is the
greater
0.05
> 0.1
35 %
0
28 %
0
22 %a
0
For outside diameters D 355.6 mm it is permitted to exceed the upper wall thickness locally by a further 5 % of the wall thickness T
Tolerances for bored and turned tubes: D = 0.5 mm, d = 1.0 mm, T = 1.0 mm
Comparison of materials 1)
Service
United States
Germany
Europe
Japan
ASTM/ASME
DIN
EN
JIS
temperature
A/SA 106 A/SA 192 A/SA 209 A/SA 210 A/SA 213
17 175
A/SA 335
300 C
Gr. A
low-
VdTV material
10216-2
data sheet
3456
3458
St35.8
P235GH
STB340
STPT370
P265GH
STB410
STPT410
STB510
STPT480
STBA12
STPA12
STBA20
STPA20
10CrMo5-5
STBA23
STPA23
carbon
580 F
Gr. B
Gr. A1
St45.8
Gr. C
Gr. C
17Mn4
T1/T1A
19Mn5 2)
20MnNb6 2)
15Mo3
16Mo3
P1
16Mo5
8MoB5-4 2)
T36/P36
15NiCuMoNb5-6-4
15NiCuMoNb5-6-4
(WB36)
(WB36)
T2/P2
T11/P11
T12/P12
13CrMo4 4
13CrMo4-5
STBA22
STPA22
T22/P22
10CrMo9-10
10CrMo9-10
STBA24
STPA24
14MoV6-3 3)
14MoV6-3 3)
T24/P24
7CrMoVTiB10-10
T23/P23
STBA24J1 STPA24J1
T9/P9
X12CrMo9-1
X11CrMo9-1
STBA26
STPA26
T91/P91
X10CrMoVNb9-1
X10CrMoVNb9-1
STBA28
STPA28
STBA29
STPA29
X20CrMoV11-1 3)
VM12-SHC
X12CrCoWMoVNb12-2-2 VM12-SHC 4)
T911/P911
X11CrMoWVNb911
X11CrMoWVNb9-1-1
(E911)
625 C
1155 F
T92/P92
7CrMoVTiB10-10
7CrWVMoNb9-6
X20CrMoV12-1
1)
2)
3)
4)
3461
3462
Code case
N 2199-5
N 2327-1
N 2353-1
N 2540
N 2781
X10CrWMoVNb9-2
X10CrWMoVNb9-2
150,000 MW
Piping components
Fittings, headers or other prefabricated
products can be supplied with hotreduced or bottlenecked ends on one
or both sides. Moreover, hollow bodies
can be manufactured with integral bottom or with one thickened end.
V B01B0006B-15GB