2.1 show
Command function
Check the system information
command format
show cbat_info
user guide
Datetime; the present time of master
Starttime;the starting time of master
ConfigurationThe network info.of master is automatically or static configuration
Software Versionindicate the software Version No.
Hardware Versionindicate the hardware version
StartFreq; Start Frequency
StopFreq;End Frequency
Workmode;OFDM/CMTS
Upgrade Server Indicate the IP address when upgrade by FTP or TFTP server
Upgrade Server Port ; Update server port number
Telnet timeout
Bstorm Mode; Broadcast Limit
Bstorm Rate; The broadcast storm inhibition rate,
Dns Server;Dns servers IP,default is Dns management ip.
Ntp Server netOnly can set IP address,default is time.nist.gov
Flow Control ;the status of flow,default is enable
Dot1q Vlan ModeMasters vlan enable
For example
MEOC>>show cbat_info
Date Time : 1970-01-02 18:59:30
Start Time : 1970-01-01 00:00:27
4
No new Wires.... www.wodaplug.com
For example
MEOC>>show cbat_topo_info
Cpu Mac : 00:55:ff:01:00:01
Card Count : 1
5
No new Wires.... www.wodaplug.com
related command
command function
command format
show cbat_perf
parameter description
For example
MEOC>>show cbat_vlan_list
VLAN List: 1, 11, 20, 400, 1200,
For example
MEOC>>show cbat_vlan_info 11
VLAN: 11
Member Ports: 1, 2,
Untag Member Ports: 1, 2,
6
No new Wires.... www.wodaplug.com
For example
MEOC>>show cbat_rt_stats
Port 1:
Tx Bytes :0
Tx Unicast Packets : 0
Tx Broadcast Packets : 0
Tx Multicast Packets : 0
Rx Bytes :0
Rx Unicast Packets : 0
Rx Broadcast Packets : 0
Rx Multicast Packets : 0
Rx Dropped Packets : 0
Port 2 (Management Port):
Tx Bytes : 360795
Tx Unicast Packets : 1405
Tx Broadcast Packets : 0
Tx Multicast Packets : 0
Rx Bytes : 1734072
Rx Unicast Packets : 1415
Rx Broadcast Packets : 19765
Rx Multicast Packets : 646
Rx Dropped Packets : 0
user guide
Firstly need use show cbat_topo_info to check the S/N.No.It is the Id.
For example
MEOC>>show card_info 0
Card Id :0
Card Mac : 00:00:00:00:1a:06
Status : Reg Ok
Online Time : 1970-01-01 00:00:33
FW Version : INT7400-MAC-7-0-7001-14-31-20110706-FINAL-D
Model Number : M240NR
Isolation : Enable
IgmpSp Mode : Enable
Max Cnu : 64
7
No new Wires.... www.wodaplug.com
Cnu Count :3
Cnu Online Count : 3
Running Time : 0d:0h:5m:48s
command function
Indicate card topo information
command format
show card_topo_info(cardid)
parameter Description
Param:Need show cards S/N
For example
MEOC>>show card_topo_info 0
Card Id : 0
Card Mac : 00:55:ff:00:00:05
Cnu Count : 29
For example
MEOC>>show card_rf_info 0
Card Id :0
Link MaxChannelNum : 2452
Output Level : 105 dBuV
DownStream StartFreq : 7.5 MHz
DownStream StopFreq : 67.5 MHz
UpStream StartFreq : 7.5 MHz
UpStream StopFreq : 67.5 MHz
8
No new Wires.... www.wodaplug.com
For example
MEoC>>show card_qos 0
card ID: 0
VLAN Qos: enable TOS Qos: disable
Priority VLAN Tags TOS Bits
0 CA1 CA1
1 CA0 CA0
2 CA0 CA0
3 CA1 CA1
4 CA2 CA2
5 CA2 CA2
6 CA3 CA3
7 CA3 CA3
Default CAP:
IGMP : CA3
IGMP managed Multicast Stream: CA2
Multicast/Broadcast : CA1
Unicast : CA1
For example
MEOC>>show analog_info
AnalogType HIHI HI LO LOLO Deadband
Temperature 80 60 0 0 0
CPU 100 60 0 0 0
Memory 100 60 0 0 0
Velocity 100 60 0 0 0
9
No new Wires.... www.wodaplug.com
Yawp 100 60 0 0 0
Attenuation 100 60 0 0 0
command function
command format
show cnu_info (cnuid)
parameter description
cnuid: cnu
For example
MEOC>>show cnu_info 6
Cnu 6
Cnu Mac : 00:55:FF:00:00:46
Card Id :0
Init : Finished
Online Time : 1970-01-01 00:00:43
FW Version : INT6000-MAC-4-1-4102-00-3679-20090724-FINAL-C
Custorm Type : s122prv
Switch Type : Realtek
Port Num : 2
Authorize : Yes
Access : Deny
Status : Online
Isolation : Enable
------------------------------------
Switch Info
10
No new Wires.... www.wodaplug.com
For example
MEoC>>show cnu_qos 16
11
No new Wires.... www.wodaplug.com
cnu ID: 16
VLAN Qos: enable TOS Qos: disable
Priority VLAN Tags TOS Bits
0 CA1 CA1
1 CA0 CA0
2 CA0 CA0
3 CA1 CA1
4 CA2 CA2
5 CA2 CA2
6 CA3 CA3
7 CA3 CA3
Default CAP:
IGMP : CA3
IGMP managed Multicast Stream: CA2
Multicast/Broadcast : CA1
Unicast : CA1
For example
MEOC>>show cnu_rt_stats 28
Cnu 28
Tx Packets : 258051162
Rx Packets : 12647621
Rx Droped Packets : 0
Rx CRC Error Packets : 0
related command
show card_rt_stats
12
No new Wires.... www.wodaplug.com
For example
MEOC>>show default_cnu_config
Default Cnu Config:
Access: Deny
------------------------------------
Switch Info
IgmpSp Mode : Disable
BStorm Mode : Disable
MStorm Mode : Disable
UnkStorm Mode : Disable
Storm Rate : 80 pps
Cable Up Limit : 100 Mbps
Cable Dn Limit : 100 Mbps
Vlan Mode : Transparent
Mac Limit : 0, Disable
------------------------------------
Ethernet Port Info
LAN 1:
LinkPolicy : Auto
Pri :0
Status : Active
Pvid :1
Port Up Limit : 100 Mbps
Port Dn Limit : 100 Mbps
LAN 2:
LinkPolicy : Auto
Pri :0
Status : Active
Pvid :1
Port Up Limit : 100 Mbps
Port Dn Limit : 100 Mbps
LAN 3:
LinkPolicy : Auto
Pri :0
Status : Active
Pvid :1
Port Up Limit : 100 Mbps
Port Dn Limit : 100 Mbps
LAN 4:
LinkPolicy : Auto
13
No new Wires.... www.wodaplug.com
Pri :0
Status : Active
Pvid :1
Port Up Limit : 100 Mbps
Port Dn Limit : 100 Mbps
------------------------------------
Qos Info
Vlan Qos : Enable
Tos Qos : Disable
Priority Vlan Tags Tos Bits
0 CA1 CA1
1 CA0 CA0
2 CA0 CA0
3 CA1 CA1
4 CA2 CA2
5 CA2 CA2
6 CA3 CA3
7 CA3 CA3
TTL
CA0 CA1 CA2 CA3 MME
2000 2000 300 300 300
Default CAP
Igmp : CA3
Igmp Managed Multicast Stream : CA2
Multicast/Broadcast : CA1
Unicast : CA1
For example
MEOC>>show ip_access_list
Ip Access Control: Disable
Ip Access List (Total Num: 1):
Ip: 192.168.1.60, Netmask: 255.255.255.255
14
No new Wires.... www.wodaplug.com
For example
MEoC>>show mgmt_vlan
Management vlan :
mode:Disable
vlanid:0
MEOC>>show pre_cnu_list
Id Mac Address
--------------------------------
1 00:55:ff:00:21:03
2 00:55:ff:00:21:06
3 00:55:ff:00:21:05
4 00:55:ff:00:21:08
5 00:55:ff:01:21:05
For example
MEOC>>show pre_cnu_config 00:55:ff:01:21:05
Pre Cnu Config:
------------------------------------
Switch Info
IgmpSp Mode : Disable
BStorm Mode : Enable
MStorm Mode : Disable
UnkStorm Mode : Disable
Storm Rate : 80 pps
Cable Up Limit : 100 Mbps
Cable Dn Limit : 100 Mbps
Vlan Mode : Access
Mac Limit : 0, Disable
------------------------------------
15
No new Wires.... www.wodaplug.com
user guide
Max Times range <1-255>
Min Interval range<1-255>
Max Interva range <1-255>
For example
MEOC>>show trap_server
Ip Address : 192.168.1.55
Max Times : 255
Min Interval : 0
Max Interval : 0
16
No new Wires.... www.wodaplug.com
Community : public
Status : Enable
related command
set trap_server
For example
MEOC>>show whitelist_info
Register WhiteList Number : 3
All RF Output Level : 105 dBuV
Cnu Mac Limit Number : 8
Phy Rate Gate : 200000000 bps
Cnu 8 Info
Card Id :0
Cnu Mac : f4:3e:61:da:19:c8
Cnu Status : Online
Cnu 28 Info
Card Id :0
Cnu Mac : f4:3e:61:da:af:dc
Cnu Status : Online
Cnu 60 Info
Card Id :0
Cnu Mac : f4:3e:61:da:19:bc
Cnu Status : Online
related
add white_mac del white_mac.
command function
Show MAC black list in the system
17
No new Wires.... www.wodaplug.com
2.2. set
command format
set analog_alarm (analog) (hihi) (hi) (lo) (lolo) (deadband)
parameter specification
Analog items:,
1 Temperature
2 CPU cpu Utilization Rate
3 memory memory Utilization Rate
4 velocity link rate
5 yawp Noise
6 attenuation
hihi : too high
hi : a little high
lo : a little low
lolo : too low
deadband :dead zone value
For example
MEOC>>set analog_alarm 1 70 50 20 10 10
Set Analog Success.
2.2.2set card_igmp_snooping
command formart
set card_igmp_snooping (cardid) (mode)
parameter description
mode: enable mean open
disable mean close
For example
MEoC>>set card_igmp_snooping 0 enable
Set Card 0 IGMP Snooping Success.
18
No new Wires.... www.wodaplug.com
command format
set card_isolation (cardid) (mode)
parameter description
mode:enable
disable
For example
MEoC>>set card_isolation 0 disable
Set Card 0 Isolation Success.
command format
set card_qos_dscp (cardid) (mode)
parameter description
mode:enable
disable
For example
MEoC>>set card_qos_dscp 0 enable
Set Card 0 QoS Dscp enable Success.
related command
show card_qos
command format
19
No new Wires.... www.wodaplug.com
show card_qos
command format
set card_qos_queue_ttl(cardid) (queue) (ttl)
parameter description
queue: CA0~CA3,MME
ttl: 10~65000
Ttl MME range is 3002000
For example
MEoC>> set card_qos_queue_ttl 0 CA2 300
Set Card 0 QoS TTL Success.
related command
show card_qos
command format
set card_qos_service_pri (cardid) (type) (queue)
parameter description
typeunicast
mcast
igmp
avstream IGMP Controlled multicast
For example
MEoC>> set card_qos_service_pri 0 mcast CA1
Set Card 0 QoS Service Priority Success.
related command
show card_qos
20
No new Wires.... www.wodaplug.com
disable
For example
MEoC>> set card_qos_threshold 0 enable
Set Card 0 QoS Threshold Enable Success.
related command
show card_qos
command format
set card_qos_tos_mapping (cardid) (queue) (tos)
parameter description
queue: CA0~CA3
tos:0~7
user gudie
CA3 is the highestCA0 is the lowest
For example
MEoC>> set card_qos_tos_mapping 0 CA2 4
Set Card 0 QoS Tos Mapping Success.
related command
command function
enable or disable qoss vlan function
21
No new Wires.... www.wodaplug.com
command format
set card_qos_vlan (cardid) (operation)
parameter description
param: enable
disable
For example
MEoC>> set card_qos_vlan 0 enable
Set Card 0 QoS Vlan enable Success.
related command
show card_qos
command function
Set the mapping between qos and vlan
command format
set card_qos_vlan_mapping (cardid) (queue) (vlanid)
parameter description
queue CA0~CA3:
user guide
CA3 is the highestCA0 is the lowesst
For example
MEoC>> set card_qos_vlan_mapping 0 CA3 3
Set Card 0 QoS Vlan Mapping Success.
related command
show card_qos
command function
Remove the card real-time performance information
command format
set cbat_rt_stats_reset
parameter description
For example
MEOC>>set cbat_rt_stats_reset
Clean Cbat Realtime Statistic Success
22
No new Wires.... www.wodaplug.com
command function
Set port pvid
command format
set cbat_pvid (portid) (pvid)
parameter description
Portid cbat port No.,range<1~2> pvid cbats port vid range
is<1~4094>
For example
MEOC>>set cbat_pvid 2 200
related command
command function
enable or disable802.1q vlan
command format
set cbat_dot1q_vlan_mode (mode)
parameter description
mode(enable|disable)
For example
related command
command function
enable or disable masters broadcast limit function
command format
set cbat_bstorm_ctrl (mode)
parameter description
modeenabledisable
For example
MEoC>> set cbat_bstorm_ctrl enable
Set Cbat Broadcast Storm Control Enable Success.
23
No new Wires.... www.wodaplug.com
related command
command format
cbat_bstorm_rate
For example
MEOC>>set cbat_bstorm_rate 10
related command
command format
set cbat_flow_ctrl (mode)
parameter description
Modeenable|disable
Enable
Disable
For example
MEOC>>set cbat_flow_ctrl disable
related command
For example
MEOC>> Set cbat_max_cnu_count 10
24
No new Wires.... www.wodaplug.com
For example
command function
Remove the slaves real-time performance information
command format
set cnu_rt_stats_reset (cnuid)
For example
MEOC>>set cnu_rt_stats_reset 28
Clean Cnu :28 Realtime Statistic Success.
command function
Set the uplink and downlink bandwidth of cnu
command format
set cnu_cable_speedlimit (cnuid) (uplink) (downlink)
parameter description
uplink
downlink
For example
MEOC>>set cnu_cable_speedlimit 24 1 16
Set Cnu:24 Speed limited Success.
command function
enable or disable cnus igmp snooping
25
No new Wires.... www.wodaplug.com
command format
set cnu_igmpsp_ctrl (cnuid) (mode)
parameter description
modeenable | disable
For example
MEOC>> set cnu_igmpsp_ctrl 16 enable
Set Cnu:16 IGMP Snooping Control Enable Success.
command function
enable or disable
command format
set cnu_loopdetect_mode (cnuid) (mode)
parameter description
Cnuidcnu id
modeenable|disalbe
For example
MEOC>>set cnu_loopdetect_mode 16 enable
Set Cnu:16 Loop Detection Enable Success.
For example
command function
Set cnu max qty of access
command format
set cnu_maclimit (cnuid) (macnum)
26
No new Wires.... www.wodaplug.com
parameter description
The qty of macnum is [0,8]
For example
MEOC>> set cnu_maclimit 16 5
Set Cnu:16 Mac Limit Success.
For example
MEOC>>set cnu_mstorm_ctrl 28 enable
Set Cnu:28 Multicast Storm Control Enable Success.
command function
Set cn port workmode
command format
set cnu_port_linkpolicy (cnuid) (port) (linkpolicy)
parameter description
linkpolicyauto
100_full
100_half
10_full
10_half
For example
MEoC>> set cnu_port_linkpolicy 16 1 auto
Set Cnu 16 Port 1 Linkpolicy Success.
For example
MEoC>> set cnu_port_pri 16 1 4
Set Cnu:16 Port 1 Pri 4 Success.
27
No new Wires.... www.wodaplug.com
For example
MEOC>> set cnu_port_pvid 16 1 5
Set Cnu:16 Port 1 Vlan Success.
related command
For example
MEOC>> set cnu_port_status 16 1 open
Set Cnu:16 Port 1 status open Success.
command function
Set cnu port speedlimit
command format
set cnu_port_speedlimit (cnuid) (port) (upspeed) (downspeed)
parameter description
Cnuidcnus ID no.
Portcnu port NO.
Upspeeduplink
Downspeeddownlink
For example
MEOC>>set cnu_port_speedlimit 24 1 5 5
Set Cnu:24 Port 1 Speedlimit Success.
For example
MEOC>> set cnu_port_isolation_mode 31 enable
related command
28
No new Wires.... www.wodaplug.com
For example
MEOC>> set cnu_qos_dscp 16 enable
Set Cnu 16 QoS Dscp Enable Success.
related command
For example
MEOC>> set cnu_qos_vlan 16 enable
Set Cnu 16 QoS Vlan Enable Success.
command function
Set the percent of priority queue in intellon chipcommand format
set cnu_qos_queue_threshold (cnuid) (queue) (percent)
parameter description
queueCA0CA3
percent:
user guide
CA3 is the highestCA0 is the lowestunable be allowed to be set
For example
MEoC>> set cnu_qos_queue_threshold 16 CA1 25
Set Cnu 16 QoS Queue Threshold Success.
For example
MEoC>> set cnu_qos_queue_ttl 16 CA1 3000
Set Cnu 16 QoS TTL Success.
29
No new Wires.... www.wodaplug.com
For example
MEoC>> set cnu_qos_service_pri 16 mcast CA1
Set Cnu 16 QoS Service Priority Success.
For example
MEoC>> set cnu_qos_threshold 16 enable
Set Cnu 16 QoS Threshold Enable Success.
command function
enable or disablecnu qos tos
command format
set cnu_qos_tos (cnuid) (operation)
parameter description
operation:enable disable
For example
MEoC>> set cnu_qos_tos 16 enable
Set Cnu 16 QoS Tos Enable Success.
For example
MEoC>>set cnu_qos_tos_mapping 16 CA1 4
Set Cnu 16 QoS Tos Mapping Success.
For example
MEoC>> set cnu_qos_vlan_mapping 16 CA2 7
Set Cnu 16 QoS Vlan Mapping Success.
30
No new Wires.... www.wodaplug.com
For example
MEOC>>set cnu_stormctrl_pps 28 10
Set Cnu:28 Bstorm PPS Success.
For example
MEoC>> set cnu_vlanmode 16 access
Set cnu:16 Vlan Mode Success.
For example
MEoC>> set cnu_unkstorm_ctrl 16 enable
Set Cnu:16 Unknown Storm Control Enable Success.
For example
MEOC>>set dns_server 192.43.244.18
Set Ntp Server Success.
command function
Set systems ip
command format
set ipaddr (ipconfig) (ip) (netmask) (gateway)
parameter description
ipconfig: static-> IP
dhcp-> IP
31
No new Wires.... www.wodaplug.com
ip
netmas k
gateway
For example
Static
MEoC>> set ipaddr static 192.168.0.247 255.255.255.0 192.168.0.1
/*******************************caution**************************/
/*If you want to take effect the IP address,please Reset system*/
/****************************************************************/
Dhcp.
MEOC>>set ipaddr dhcp
Set Cbat Ip Success.
/*******************************caution**************************/
/*If you want to take effect the IP address, please Reset Cbat!*/
/****************************************************************/
command format
set ip_access_ctrl (enable|disable)
For example
For example
MEoC>> set mgmt_vlan disable 8
/*******************************caution**************************/
/****Take effect the management vlan config,Need Reset Cbat****/
/****************************************************************/
32
No new Wires.... www.wodaplug.com
command function
Set trapservers information
command format
set trap_server (serverip) (maxtimes) (mininterval) (maxinterval) (community) (status)
parameter description
serveripip
maxtimes: range at <0~255>
mininterval: <0~255>
maxinterval: <0~255>
community.
status:enable|disable
For example
MEOC>> set trap_server 192.168.0.125 200 100 3000 public enable
Set TrapServer Config Success.
related command
Show trap_server
command function
ip
command format
set upgrade_server (serverip) (port) (user) (password)
parameter description
Serverip:p
port
use
password
user guide}
show cbat_info to check whether upgrade sucessfully
For example
MEOC>> set upgrade_server 192.168.0.9 21 root public
Set Upgrade Server Success.
command format
33
No new Wires.... www.wodaplug.com
command format
set default_cnu_bstorm_ctrl (mode)
parameter description
mode : enable
disable
For example
command format
set default_cnu_mstorm_ctrl (mode)
parameter description
mode : enable --
disable
command format
set default_cnu_unkstorm_ctrl (mode)
parameter description
mode : enable
disable
command format
set default_cnu_stormctrl_pps (number)
parameter description
34
No new Wires.... www.wodaplug.com
number : 640,320,160,80,40,20,10
command format
set default_cnu_cable_speedlimit (upspeed) (downspeed)
command format
set default_cnu_port_speedlimit (port) (upspeed) (downspeed)
parameter description
command format
set default_cnu_vlanmode (mode)
parameter description
mode : transparent ,disable vlan
access enable vlan
command format
set default_cnu_maclimit (number)
command format
set default_cnu_port_linkpolicy (port) (linkpolicy)
parameter description
linkpolicy : auto
100_full
100_half
35
No new Wires.... www.wodaplug.com
10_full
10_half
command format
set default_cnu_port_pri (port) (pri)
parameter description
pri : 0~7
command format
set default_cnu_port_status (port) (status)
parameter description
status : open
close
command format
set default_cnu_port_pvid (port) (pvid)
parameter description
pvid : 1~4094
36
No new Wires.... www.wodaplug.com
2.3. add
command function
Creat vlan
command format
add cbat_vlan (vlanid)
parameter description
Vlanid:<1~4094>
command function
Add vlan member and set the rules
command format
add cbat_vlan_member (vlanid) (portid) (mode)
parameter description
Vlanid:<1~4094>
Portid:<1~2>
Mode: (tag|untag) tag is pors pvid value untag will be showed in
cbat_vlan_info
For example
MEOC>>add cbat_vlan_member 1 1 untag
related command
MEOC>>show cbat_vlan_info 1
Vlan: 1
Member Ports: 1, 2,
Untag Member Ports: 1, 2,
For example
MEOC>>add ip_access_allow 192.168.1.60 255.255.255.255
Add Ip Access Allow Success.
related command
37
No new Wires.... www.wodaplug.com
For example
MEOC>>add whitelist 28
Add White Mac Success.
related command
show whitelist_info
2.4. del
command function
Delete vlan
command format
del cbat_vlan (vlanid)
parameter description
Vlanid<1~4094>
command function
Delete vlan members
command format
del cbat_vlan_member (vlanid) (portid)
parameter description
Vlanid<1~4094>
Portid<1~2>;
command function
Delete slaves
2
1 offlining
38
No new Wires.... www.wodaplug.com
2 offline
command format
del cnu (cnuid)
parameter description
For example
MEoC>> del cnu 41
Del Cnu 41 Success.
MEOC>>del cnu 41
ERROR :Cnu Offlining, Try Later
ERROR :Ceserver Return Error!
command format
ip_access_allow (ip) (netmask)
parameter description
Ipip
Netmask
For example
MEOC>>del ip_access_allow 192.168.0.0 255.255.255.255
Del Ip Access Allow Success.
command function
Delete mac white list
command format
del whitelist (cnuid)
For example
MEOC>>del whitelist 28
Del White Mac Success
related command
show anonymitylist_info
39
No new Wires.... www.wodaplug.com
2.5. reset
command function
Reset cards intellon chip
command format
reset card (cardid)
For example
MEoC>> reset card 2
Restart Card Success.
command function
Reset cbat
command format
reset cbat
For example
MEoC>> reset cbat
Reset Cbat Success.
command function
Reset cnus intellon chip
command format
reset cnu (cnuid)
For example
MEoC>> reset cnu 5
Reset Cnu 5 Success
related command
40
No new Wires.... www.wodaplug.com
2.6 restore
For example
MEoC>> restore cbat_factory_default
Restore Cbat Factory Default Configuration Success
For example
MEoC>> cnu_factory_default 2
Restore Cnu 2 Config Success.
2.7. upgrade
command format
upgrade app
command function
Upgrade masters software-kernel
command format
upgrade kernel (kerne)
3.Cablengine MEoC
3.1 keepalive
For example
MEOC>>keepalive 200
Set Telnet Keepalive Timer Success
41
No new Wires.... www.wodaplug.com
MEOC>>keepalive
Telnet Keepalive Timer : 300s
related command
3.2. logout
command function
Quit CLI interface
command format
logout
For example
MEoC>>logout
3.3. who
command format
who
For example
MEoC>>who
+------------------------------------------------------+
| User Name | Login Channel | Login time |
+------------------------------------------------------+
| root | TELNET | Wed Apr 22 20:51:50 2009
+------------------------------------------------------+
42