Electronic Control Module (ECM) - Flash Program
Electronic Control Module (ECM) - Flash Program
Page 1 of 4
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: E200B EXCAVATOR 6KG
Configuration: CROSS-REFERENCE LIST OF PTNR TO SCM, CBSA, DECATUR & MOSSVIL 6KG00001-UP (MACHINE)
i04490315
Perform the following procedure in order to flash program the PL522 and 523. The PL522 and 523 is
flashed in order to upgrade the software. Flash programming of the PL522 and 523 must also be done if the
PL522 and 523 have been replaced. The Caterpillar Electronic Technician (Cat ET ) contains the program
WinFlash. WinFlash is used in order to load software into the PL522 and 523.
Refer to Systems Operation, Troubleshooting, Testing and Adjusting, "Configuration" in order to configure
the PL522 and 523.
Note: The Communication Adapter II is available in order to flash program the electronic control modules.
The Communications Adapter II hardware is connected between the service connector of the machine and
the PC serial port or the PC parallel port. The Cat ET "Communications Interface Device" is configured for
"Caterpillar Communications Adapter II (RP1210)".
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/f... 9/6/2017
CROSS-REFERENCE LIST OF PTNR TO SCM, CBSA, DECATUR & MOSSVIL 6KG... Page 2 of 4
Illustration 1 g02173443
Illustration 2 g02173445
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/f... 9/6/2017
CROSS-REFERENCE LIST OF PTNR TO SCM, CBSA, DECATUR & MOSSVIL 6KG... Page 3 of 4
2. To flash the gateway board within the PL522 and 523, select the "Blank ECM" with the matching
serial number of the PL522 or 523 from the list of detected ECMs. Refer to Illustration 2.
Illustration 3 g02173446
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/f... 9/6/2017
CROSS-REFERENCE LIST OF PTNR TO SCM, CBSA, DECATUR & MOSSVIL 6KG... Page 4 of 4
Illustration 4 g02173595
5. The progress bar should appear while the program is being loaded. Refer to Illustration 4.
Copyright 1993 - 2017 Caterpillar Inc. Wed Sep 6 07:33:53 UTC+0700 2017