Inspection Item Color Code
Inspection Item Color Code
Be sure that the electrical tools and equipment and their cords are in good condition before use.
1. All cord sets and electrical tools shall be inspected before use.
2. Cord set testing will be completed by a competent person, designated by Elkhorn
Construction, Inc and trained in proper test procedures by Safety or Certified Electrician.
This competent person will be responsible for inspections and testing of cord sets on
assigned work sites.
3. Any defective tools or cord sets shall be tagged "Danger - Do Not Use."
4. No equipment shall be returned to use until it has been repaired and tested.
5. Documentation on daily visual inspections is not required but if faulty equipment is
detected during a safety audit it will be assumed that the inspections are not being done.
6. Colored tape shall be used to indicate that cord sets or electrical tools have been tested.
Tape colors are:
Jan, Feb, Mar White
Apr, May, June Green
July, Aug, Sept Red
Oct, Nov, Dec Blue
7. Portable electrical equipment that is not double insulated shall be tested with the proper
equipment quarterly and these tests shall be documented.
8. All cord sets shall be tested quarterly and the results of these tests shall be documented.
9. All equipment that is found to be faulty and is repaired shall be tested before the
equipment is placed back in service and the results of electrical testing shall be
documented.
10. GFCI’s must be tested before use and quarterly using the following procedure:
Press and release the test button and then plug a lamp into the GFCI
Push and release the reset button (the lamp should light)
Press and release the test button and the reset button should pop out, and the light should
go out
If the GFCI tripped but the light remained on, the line and load connections are reversed
Inspection Items
1. All Tools – Company owned and employee owned which are on our jobsite
Hand Tools
Power Tools
2. Fall Protection Items
Body Harness
Lanyard
Self Retracting Lanyard
Hooks / Carabineer
D-Ring
Tie Off Adapter
Anchorage Plates
Self Retracting Lifelines
3. Vehicles – Company owned and leased
First Aid Kit (10 person kit)
2 ½ lb Fire Extinguisher inside vehicle
Emergency triangle
20 lb Fire Extinguisher mounted in the truck bed. Mounted with proper mounting
bracket. Required on all vehicles equipped with additional fuel tank or hauling
flammable liquids
Vehicle check list
Insurance
Registration
DOT inspection tag
Registration sticker on license plate
Equipment number posted
Receiver hitch and ball
1 7/8” Painted Green
2” Painted Blue
2 5/16” Painted Yellow
4. Heavy Equipment
5 lb Fire extinguisher mounted inside the cab
Equipment number posted
Equipment inspection book
5. Scaffold
Follow Elkhorn Construction Policy and OSHA
6. Ladder
Follow Elkhorn Construction Policy and OSHA
7. Rigging
Follow Elkhorn Construction Policy and OSHA
Belts
Shackle / Clevis
Wire Rope
8. Atmospheric Monitors
Multi Gas Monitors
H2S
9. Fire Extinguisher
Record and document all inspections completed on corresponding inspection log. All items are to
be inspected prior to every use as well as monthly with the exception of the quarterly electrical
inspection.