Modul 3
Modul 3
A+BC
Follows an elementary rate law and takes place in a 1-m3 CSTR, to which the volumetric
flow rate is 0.5 m3/min and the entering concentration of A is 1 M. The reaction takes
place isothermally at 300 K. For an equal molar feed of A and B, the conversion is 20%.
When the reaction is carried out adiabatically, the exit temperature is 350K and the
conversion is 40%. The heat capacities of A, B, and C are 25, 35, and 60 kJ/mol/K,
respectively. It is proposed to add a second reactor of the same size downstream in series
with the first CSTR. There is a heat exchanger attached to the second CSTR with UA =
4.0 kJ/min/K, and the coolant fluid enters and exits this reactor at virtually the same
temperature the coolant feed enters 350 K.
(a) What is the rate of heat removal necessary for isothermal operation?
(b) What is the conversion exiting the second reactor?
(c) What would be the conversion if the second CSTR were replaced with a 1-m3 PFR
with Ua = 10 kJ/m3 /min and Ta = 300 K?
(d) A chemist suggest that at temperatures above 380 K the reverse reaction cannot be
neglected. From thermodynamics, we know that at 350 K, Kc = 2 dm3/mol. What
conversion can be achieved if the entering temperature to the PFR in part (c) is 350
K?
(e) Write an in-depth question that extends this problem and involves critical thinking,
and explain why it involves critical thinking.
(f) Repeat part (c) assuming the reaction takes place entirely in the gas phase (same
constants for reaction) with CT0 = 0.2 mol/dm3.
AB
is to be carried out in a jacketed CSTR. Species A and in inert I are fed to the reactor in
equimolar amounts. The molar feed rate of A is 80 mol/min.
(a) What is the reactor temperature for a feed temperature of 450 K?
(b) Plot the reactor temperature as a function of the feed temperature.
(c) To what inlet temperature must the fluid be preheated for the reactor to operate at a
high conversion? What are the corresponding temperature and conversion of rhe fluid
in the CSTR at this inlet temperature?
(d) Suppose that the fluid is now heated 5C above the temperature in part (c) and then
cooled 20C, where it remains. What will be the conversion?
(e) What is the inlet extinction temperature for this reaction system?
(Ans.: T0 = 87C.)
Additional information:
Heat capacity of the inert: 30 cal/g mol.C = 100 min
Heat capacity of A and B: 20 cal/g mol/C HRx = -7500 cal/mol
UA: 8000 cal/min/C k = 6.6 x 10-3 min-1 at 350 K
Ambient temperature, Ta: 300 K E = 40,000 cal/mol/K
𝐴 ↔𝐵
takes place in a CSTR with a heat exchanger. Pure A enters the reactor.
(a) Derive an expression (or set of expressions) to calculate G(T) as a function of heat of
reaction, equilibrium constant, temperature, and so on. Show a sample calculation
for G(T) at T = 400 K.
(b) What are the steady-state temperatures? (Ans.: 310, 377, 418 K.)
(c) Which steady states are locally stable?
(d) What is the conversion corresponding to the upper steady state?
(e) Vary ambient temperature Ta and make a plot of the reactor temperature as a
function of Ta, identifying the ignition and extinction temperatures.
(f) If the heat exchanger in the reactor suddenly fails (i.e., UA = 0), what would be the
conversion and the reactor temperature when the new upper steady state is reached?
(Ans.: 431 K)
(g) What heat exchanger product, UA, will give the maximum conversion?
(h) Write a question that requires critical thinking and then explain why your question
requires critical thinking. [Hint: See Preface Section B.2.]
(i) What is the adiabatic blowout flow rate, 0.
(j) Suppose that you want to operate at the lower steady state. What parameter values
would you suggest to prevent runaway?
Additional information:
K = 1 min-1 at 400 K
In a 1.2 m3 ideal tank reactor, component A reacts (CA0 = 5 kmol m-3) by a first order reaction
with the following rate constant:
k=20.31 106 exp (-9370/T) s-1
The heat capacity and density of the reacting fluid does not vary neither with temperature nor
composition and is respectively 4.19 kJ kg-1 K-1 and 1000 kg m-3. The reaction enthalpy (ΔHR)
can also be considered constant over the applicable temperature interval (-83.8 kJ mol-1). The
average residence time in the reactor is 1.2 h. For the heat exchanger in the tank, the overall heat
transport coefficient is 2000 kJ m-2 h-1 K-1. The heat exchanger’s area is 3 m2. The cooling
fluid has a large heat capacity and flow rate, thus its temperature can be considered constant at
88°C. The reactor feed temperature is 70°C.
Determine the reactor’s steady state operating condition(s) and examine whether they are stable.