B Protection Relay
ADR211A (Communicable)
(ADITYA Series)
(Preliminary)
Features:
• Single Element (Phase/EF) Over
current IDMT with instant trip.
• Back - lit LCD display for
settings.
• Display of fault current. / Load
current.
• Selection of Curve: Six
selectable curves (Normal
Inverse1 (C1), Normal Inverse2
(C2), Very Inverse (C3),
Extremely Inverse (C4), Long
Time Inverse (C5) & Definite
Time (C6).
• Design using DSP technology.
• Latching of fault current up-to last
5 fault
• Password protection for setting.
• Site selectable CT secondary
• Relay can be made ether IDMT or Define time
• Programmable operating time in instantaneous element
• Breaker Fail & Trip Circuit Supervision Function
• Programmable Annunciation Contact
• RS 232 (at front) and RS 485 (at rear side) Communication Port for remote SCADA (only for
ADR211A i.e. communicable Relay).
General:
The ADR111A is member of Ashida Numerical Relay family (Aditya Series) design to meet demand of
low and medium switchgear control. The ADR111A is a Single Pole Protection relay with Instantaneous
high set and programmable output to simplify feeder protection wiring. The ADR111A continuously
monitors phase current, through CT connections. The high-speed micro-controller samples this current
through a 12-bit A/D converter. The micro-controller performs powerful Digital Algorithms to find out
Amplitude of current signal, and then this value is use for protection and metering function. All
measurement is tuned to fundamental frequency. Each input current is also displayed on 16 x 2 LCD
display for metering. The Relay is having main three functions 1) Protection 2) Self-Supervision 3)
Measurement
The Relay can be supplied with different model. It can be either Definite Time or IDMT.
Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary
slightly from that indicated above.
1. Protection Functions:
The ADR111A give maximum benefit/cost ratio. The ADR111A give all the advantage of numerical relay
at affordable cost. Following is summery of different protection functions provided by relay.
2. Supervision Function:
2.1 Self-supervision:
The continuously keeping track on its internal hardware and the movement it detect any failure of any
component, it give message on LCD display, This feature is very useful to give pre information to avoid
any mall - operation. In such situation it use some default setting and remain in protection mode.
3. Measurement Function:
In normal condition this display shows all settings. Via keyboard the display can be program to show the
actual current flowing through the relay. If current excesses set value the relay gives trip command. The
type of fault is displayed on LCD display. During the fault condition the relay measure the fault
current and store in non-volatile memory. The fault current can be read via keyboard on LCD
display Last 5 fault values along with tripping counter can be view via key-board. All settings are
save in electrically erasable read only memory and remain.
Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary
slightly from that indicated above.
5. Status :
Status input S1 and S2 are general purpose for SCADA application and S3 and S4 are dedicated for CB
NC and NO used for trip circuit supervision.
Ordering Information:
The relay is available with nos. of different option. The option is specified by model no. It is user
responsibility to specify correct model no. while ordering.
While Or d e ring Spe cify t he fo llow ing Info rm at io n for A DR11 1A Re la y
Definition of Model No of Aditya Se rie s of Relays
AM XX X– XX – X – X – X X – X
Reserved for Future Use
Auxiliary Supply
01 = 18 – 52 V dc
PT Secondary
0 02 = 77 – 250 V dc
03 = 110 VAC
04 = 230 VAC
05 = 60 V dc
CT Secondary
1 = 1 Amp. 06 = 18 - 250 V dc
2 = 5 Amp.
3 = 1 Amp. / 5 Amp. Selectable
AM XXX XX X
Single Pole Relay
101 01 Relay with site selectable CTs, Trip circuit supervision CSA – 150 3
and breaker fail function. 2 extra Ann. Contacts and 4
optically isolated status inputs ( 2nos for TCS )
O rd e ri n g i n f o r m a t i o n :
A D R 1 1 1 A - A M - X X X - X X - X - X - X X - X
E xa m p l e
ADR 1 1 1 A – AM - 1 0 1 -0 1 -3 - 0 -2 - 0
T yp e : A D R1 1 1 A
B a c k Te r m i n a l L a y o u t : With 2 Programmable extra contacts, Selectable CT TCS Logic.
C a b i n e t Ty p e : C SA - 1 5 0 n o n D r a w o u t
A u xi l i a r y S u p p l y : 7 7 -2 5 0 V d c
C T s e c : 1 / 5 Amp.
Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary
slightly from that indicated above.
: Inst Operating Time Inst = < 30ms and additional adjustable software
delay of 00 – 2.0Sec in steps of 10ms.
Output contacts : Model 1) 2 NO Trip duty contact for Alarm and Trip
AM10101xxxxx 2) 2 NO ANN. Duty contacts ( Programmable)
II. Pickup Current : Within 1.1 times of set current value.
III. Resetting Current : 90% of set value.
IV. Time Accuracy : Within class 2.5 As per IS: 3231.
V. Burden on CTs : Less than 0.2VA.
VI. Aux. Supply : 18 – 52VDC or 77 – 250VDC. To be specified while ordering.
VII. Burden on Aux. Supply : Less than 10VA on any supply.
VIII. Contact Rating Trip Duty : Make and carry for 3sec. – 7500VA with max. 30A & 660VAC/DC
: Make and carry for continuous – 1250VA with max. 5A & 660VAC/DC
: Break AC – 1250 VA DC – 100 W resistive 50W inductive.
IX. Operational Indicators (Flags)
ON / Error : Green LED indicates Relay OK
: Red LED indicates Problem in relay Hardware.
PKP : Red LED’s indicates the Over Current relay Pickup.
FAULT : Red LED’s indicates the Over Current relay trip, Hand Reset (HR) Type.
TRIP : Indicates that Trip pulse is being executed. When BYPASS P.B. is
pressed, actual trip is not executed.
X. Thermal Withstand Capacity : X40 times the normal current for 3sec.
: x2 Continuous
XI. High Voltage Test : IEC 60255-5
: Except DC Voltage – 2.0 kV (RMS), 50Hz
: Only DC voltage - 2.8 kV DC
: Between Open contact of TRIP / CLOSE 1.5kV (RSM) 50Hz
: Between Open contact of ALARM – 1kV (RSM) 50Hz
Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary
slightly from that indicated above.
Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary
slightly from that indicated above.
Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary
slightly from that indicated above.