NITOPROOF
NITOPROOF
Uses Description
The high elasticity, excellent bond and low water permeabil- Nitoproof 600 single component pitch modified polyurethane
ity of Nitoproof 600 make it ideal for a wide range of water/ cures by reaction with atmospheric moisture to give a tough
vapour proofing applications such as foundations, base- elastomeric waterproof membrane. It is supplied in a single
ments, tunnels, ground floors, suspended floors, car decks, grade to meet all site application methods and requirements.
roof terraces, balconies, patios, bridges, precincts, inspec-
Nitoproof 600 is a medium viscosity grade (approximately
tion pits, water retaining structures (not potable water),
600 poise) for roller, squeegee or spray application to hori-
sewage works, and inverted roofs. The excellent chemical
zontal and vertical surfaces.
resistance of Nitoproof 600 makes it particularly suitable for
tanking applications in areas where aggressive ground water
Properties
conditions prevail.
Tack free time @ 25°C : 15 hours
Advantages Time to full cure @ 25°C : 48 hours @ 1.3mm thick-
ness
One component; ready to apply direct from the can
Typical cured membrane properties (at 28 days)
Liquid application means details are simplified and there
Elongation
are no joints in the membrane
(ASTM D412) : 620 %
Highly elastic, cures to give a permanently flexible resil- Tensile strength
ient barrier over a wide range of temperatures (ASTM D412) : 1.5 N/mm2
Tear resistance
Rapid installation; significantly reduces time spent on
(ASTM D624) : 10 N/mm
preparatory works and detailing
Water vapour transmission
Excellent adhesion, can be applied to a wide range of (ASTM E96) : 0.57 g/h/m2
substrates. Continuous adhesion prevents lateral migra- Shore A hardness
tion of water (ASTM D2240) : 15 ± 5
Artificial weathering : No loss of flexibility after
Impervious - outstanding barrier properties ensure pro-
4000 hours exposure
tection against corrosive soil conditions
Service temperature (con-
Thermally stable - irreversible chemical cure eliminates tinuous ambient) : -40°C to 70°C
melting and flow at high temperature * 1ng = 10-12kg
Mechanical damage to the membrane can be easily Nitoproof 600 is unaffected by a range of mild acids, alkalis
repaired by spot application and water borne salts and is resistant to bio-deterioration.
Standard compliance
Preparation All right angle bends must have a cant strip or coving detail
installed. This may be formed in either sand & cement or
All surfaces to be waterproofed should be sound, clean and
Plastijoint*† and it must be bedded into a layer of Nitoproof
dry.
600, then given a reinforcing pretreatment by application of a
Concrete surfaces should have a light steel-trowel followed 1.3mm thick coat extending 150mm either side of the cov-
by a fine hair-broom or equivalent finish which is dry and free ing. Whilst still wet, a 150mm wide strip of Nitoproof Scrim is
of dust, oil and other contaminants. All high spots should be embedded into the Nitoproof 600 as reinforcement (ensure
removed. thorough wetting).
Moss and lichen must be removed physically followed by All other angles, joints, protrusions and stress points should
treatment with fungicidal wash to kill any spores and inhibit be pretreated with a heavy application of Nitoproof 600
further growth. After treatment wash down thoroughly with extending 50-100mm either side of the detail. Reinforcement
clean water and allow to dry. with Nitoproof Scrim is recommended where movement is
possible.
All metal surfaces should be made clean of paint, oils, rust
and other contaminants. Abrade to expose bright metal then Allow pretreatments to cure overnight before general applica-
wipe clean with Fosroc Solvent 102 prior to priming. tion.
Priming Application
Priming is not normally required on good quality concrete Nitoproof 600 should be applied by brush, trowel, squeegee
substrates. However, absorbent surfaces such as porous or airless spray (two coat application for standard grade on
concrete, sand/cement and cement boards will require sealing vertical surfaces) at a minimum wet film thickness of 1.3mm
to prevent absorption of Nitoproof 600. This should be done (1.3 litre/m2). This is in addition to the preparatory work.
using a 1:1 mixture of Nitoproof 600 and Fosroc Solvent 102.
The minimum application life (after opening the pack) is up to
Use Nitoprime 32* as a primer for bituminous surfaces. All
48 hours if stored in closed containers.
metal and PVC surfaces should be cleaned and abraded
before priming. During summer season and prolong storage it is recommend-
ed to agitate the material using slow speed mechanical mixer
Movement joints
prior to use.
All expansion and movement joints should be sealed with Ni-
On a vertical surface a film build of 1.3mm is achievable
toseal 220*†. When cured, Nitoseal Debonding Tape*† should
in two coats. In critical applications where surety of film
be applied to the top surface of the sealant and the joint then
thickness is paramount, two coats should be applied at right
overcoated with a 1.3mm thick application of Nitoproof 600
angles to one another. Quantities per coat should be gauged
extending 150mm each side of the tape. Embed a 100mm
to give the specified final film thickness.
or 150mm wide strip of Nitoproof Scrim*†, then allow to cure
before general application. A short haired synthetic pile roller should be used if applying
by roller. For spray application, use a Graco King type pump
Cracks
with 60:1 ratio at pressure 5.5 bar (80 psi), hose diameter
All shrinkage and non-moving structural cracks should be 13mm with a 10mm wip end. Tip size: 0.58mm - 0.84 (23-33
pretreated with not less than a 1.3mm coating of Nitoproof thou).
600 extending 75mm either side of the crack. Allow to cure
If a water test is to be run, the membrane should be fully
overnight before general application.
cured.
Flood test
Nitoproof 600 membrane must be cured for a minimum of 24 Nitoproof 600 will have a minimum shelf life of 12 months
hours @ 25°C before placing protection. Where damage to if stored in normal warehouse conditions between 15 and
the membrane is possible (by traffic, backfilling, etc) it should 40°C. Protect from temperatures below 10°C.
be protected by a cementitious screed or protection boards. A
Nitoprime 32 has a shelf life of 12 months if kept in a dry
dust coat of cement should be used to prevent adhesion of the
store in the original, unopened packs.
membrane to the boards. Where a bond with the topping is
not required, a separator sheet should be used.
Precautions
To prevent damage to the membrane it is recommended that
Health and safety
Nitoproof 600 is laid in strips of 1 metre width to permit the
application of a screed or Protection Board from the uncoated Some people are sensitive to resin systems. Gloves and a
area. barrier cream such as Kerodex Antisolvent, Rozalex Antipaint
or Debba-Wet-Work should be used when handling these
All exposed areas of Nitoproof 600 should be coated with
products. If contact with the resin occurs it must be removed
Nitoproof Reflectacoat*† to ensure maximum resistance to
before it hardens with a resin removing cream such as kero-
ultraviolet radiation.
cleanse Standard grade Skin cleanser or Rozaklens Indus-
Cleaning trial Skin cleanser. Follow by washing with soap and water.
Do not use solvent. The use of goggles is recommended
Tools and equipment should be cleaned with Fosroc Solvent
but should accidental eye contamination occur, wash thor-
102 immediately after use. Do not use the solvent for thinning
oughly with plenty of water and seek medical advice. Ensure
except where a sealing coat is required.
adequate ventilation when using resin and solvent containing
materials.
Limitations
Fire
- Application should not commence if the temperature of the
substrate is below 5°C. Nitoproof 600, Nitoproof Reflectacoat and Fosroc Solvent 102
contain flammable solvents. Do not use near an open flame
Technical support or smoke during use.
Supply
Nitoproof 600 : 20 litre drums
Nitoprime 32 : 4.5 litre packs
Nitoproof Reflectacoat : 20 litre containers
Nitoproof Scrim : 1000 mm wide x 50 m long
Fosroc Solvent 102 : 5 and 25 litre containers
Coverage
Nitoproof 600 : 0.76 m2/litre @ 1.3 mm
Nitoprime 32 : 10 m2/litre @ 100 microns
Additional Information
fluid micro-concretes
Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for the Supply of
Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the user’s responsibility to obtain the latest version.
Head Office
telephone: (+9714) 2039699 fax: (+9714) 2859649 email: agf@fosroc.com
Al Gurg Fosroc LLC
Regional offices
Post Box 657, Dubai Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: abudhabi@fosroc.com
Bahrain, YBA Kanoo telephone: 17738200 fax: 17732828 email: bahrain@fosroc.com
United Arab Emirates Kuwait, Boodai telephone: 4817618 fax: 4832124 email: kuwait@fosroc.com
Oman, Al Amana telephone: 24815080 fax: 24817554 email: oman@fosroc.com
www.fosroc.com Qatar, Tadmur telephone: 4432365 fax: 4419517 email: qatar@fosroc.com
UAE/0282/13/H