Ebit Miner Network Management Manual

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 14

Content

1. Network Management Installation


1.1Network management installation precautions
1.2Login interface
2.LAN management
2.1Configure static IP
2.2DHCP Management
2.3Equipment Management
2.4Refresh
2.5Export out
3.Gateway management
3.1Configure static IP
3.2Equipment Management
3.3Refresh selected
3.4Refresh all
3.5Delete selected
3.6Delete all
3.7Export out
3.8Monitor
4.Network opening
4.1Scanning on the network device
4.2Gateway configuration
4.3Background management
5.Fault Maintenance
5.1Abnormal calculation
5.2The connection of the mining pool is abnormal
5.3The calculation force shows an abnormality
5.4Equipment communication is abnormal
6.Software upgrade
6.1Upgrade view
6.2Function view
6.3Extracting files

1. Network Management Installation


1.1Network management installation precautions

Note: Please read the Installation Instructions carefully before installation. Some computers need
to run <WinPcap> and <NET.Framework 4.0>.The Package provides download link(The download
link is for reference only. If you cannot install it due to the version, you need to download it
yourself.)
1.2Login interface
Note: Run the network management gadget "EbiteMinerMini.exe" program, pop up the "Ebite"
management interface, select management tools according to your own requirements;

2.LAN management
2.1Configure static IP
Note: When the device is in use on the network, all online LAN devices will be displayed in the
interface, and all or selected online running devices will be configured through the function
<Configure Selected Device> or <Configure All Devices>; the article follows <Device
Configuration> and the key introduction in "equipment maintenance"

1) Configure Selected Devices: Targeted configuration for online devices; usually applicable to
some device configurations;
Note: When assigning an IP address, you need to keep the LAN where the device is located
connected to the Internet.
2) "Configure all devices" function: All configurations for online devices; usually applicable to
unified configuration of online devices;
3) "Configure to fixed IP" function: fixed IP configuration for the online device; usually
applicable to the problem of the network running process or the new online running device, the
IP address is fixedly configured;
4) "Online automatic configuration range" function: Automatically allocates IP addresses;
usually applies to the planned IP address segment, keeps the communication between the server
and the device normal, sets the IP address of the network segment, connects to the server, and
automatically delivers the IP address. Address, the premise needs to check "Online automatic
configuration IP";
Note: This function option is described separately in the document "IP Address Automatic
Delivery Configuration Operation Guide".
2.2DHCP Management
Note: Configure the "Enable DHCP" function for the LAN device, and select the device to
automatically obtain the IP address of the network. It is recommended that the user manually
configure the device on the network. The DHCP function can be used for routine maintenance
and troubleshooting.

1) Enable DHCP: The IP address can be obtained automatically for the device to obtain the
LAN: Generally, the device fails to be obtained in Cross-Gateway Usage. You can select the device
in the LAN Usage and enable the DHCP function to obtain the IP address.
2) Disable DHCP function: Manually set the IP address for the device to disable the DHCP
function; usually obtain the failure in Cross-Gateway Usage, enable the DHCP service, and obtain
the correct IP address, subnet mask, gateway, etc. In the future, you can turn off the DHCP
function and change the fixed IP address.

2.3. Equipment management


Note: Restart the device or restore the factory configuration and restart by using the online
device for the LAN (optional part or all)
1) "Restart" function: restart function operation for LAN devices; usually, when the device fails
to obtain IP or the device data is read incorrectly, the device can be restarted.
2) "Restore factory configuration and restart" function: Restore the factory settings for the LAN
device; usually, when the device data reading error occurs, the device can be restored to the
factory configuration for device re-data configuration;
2.4Refresh
Note: By refreshing for the local area network; usually, the data information display of the
online device is incomplete during the first time, and the refresh operation can poll the number
of online devices on the LAN and the device operation information;

1) Refresh function: refreshes the online device on the LAN to poll the online device data;
usually, when some devices are slow to go online, they can be refreshed for viewing; or can be
enabled for DHCP (for example, the original fixed IP device, enable DHCP) Function), after
refreshing, the device information will be re-polled;

2.5Export out
Note: By refreshing for the LAN; usually to solve the device that is not online at the first time
and slow on the line, the refresh operation can poll the number of online devices on the LAN
again;
1) "Export Form" function: export table for LAN online devices; usually for data export into a
table, easy to use for data search;
2) Copy IP Information: Copy all IPs of the LAN device, and create a text file for pasting; usually
used to create an online device IP address book. This function corresponds to File Import in
Cross-Gateway Usage;
3) Copy IP-MAC Information: Copy all IP-MAC addresses of the LAN device, and create a text
file for pasting; usually used to create an online device IP-MAC address;

3.Gateway management
3.1Configure static IP
Note: By import device, you can import and manage the device with the relevant requirements
by IP address; usually, it is to check the faulty device, and then view the running status of each
control board, power board, power board, and fan after importing.Observe the initial direction of
the fault through software review;

1) "File Import" function: Through the export file (text file) in "LAN Usage", "File Import" is
performed here, and the imported IP device can be displayed in the dialog box below, similar to "
Network segment import function;

2) "Network segment import" function: input information for the device to be imported, such
as IP address, address range, gateway, subnet mask, etc.; correct information input can improve
the online time of the device;

3)"Auto Refresh" function: Automatic refresh for all online devices, can set the refresh interval;
usually solve the time refresh of the online device working status;
3.2 Equipment management
Note: Through device management, you can perform related device configuration and
maintenance processing of the running device, and important functions of the network
management;Generally, the service of the equipment needs to be mine configuration. The
maintenance will involve frequency configuration, fan configuration, network power
consumption configuration, network configuration, indicator configuration, temperature setting,
software upgrade, and device reboots.Subject to equipment maintenance;

1) "Mine Configuration" function: The mine pool is configured for the imported on-line
equipment, and the equipment is connected to the mine pool and miner number in the network.
2) "Frequency Configuration" function: frequency setting for the imported online device, there
will be a default frequency at the factory; usually when the temperature is too high, the
frequency will be reduced. After the device is cooled, this setting can be adjusted to adjust the
device frequency;
3) "Fan Configuration" function: configure the fan speed for online devices (low, medium and
high speed optional);
4) "Network Configuration" function: The network configuration needs to be modified for
individual devices. Usually, when the network is unstable, you can set up a device to test other
networks.
5) "Indicator Configuration" function: Turns the indicator on and off. Usually, it is to find a
faulty device. When the indicator is turned on, the indicator light is always on.
6) "Location Configuration" function: input for location information. Usually indicates the
physical location of the device;
7) "Restorer" function: device reset factory settings for a single device;
8) "Temperature Configuration" function: for the setting of the device temperature upper limit
value, usually monitor the device temperature;
9) "Software Upgrade" function: for device software upgrade;
10) "Device reboots" function: soft restart for the device;
3.3Refresh selected
Note: For the refresh operation of the online device, this function option is mainly for the
selected device; usually, the device needs to be refreshed multiple times to view the most
accurate device information;

1) "Refresh selected" function: for the refresh operation of the device, usually to determine
the final data information of the device;
3.4Refresh all
Note: For the online device refresh operation, this function option is mainly for all devices;
usually, the device needs to be refreshed multiple times to view the most accurate device
information;

1) "Refresh all" function: for the refresh operation of the device, usually to determine the final
data information of the device;
3.5Delete selected
Note: Delete operation for invalid devices; usually delete IP devices that do not exist in the
management software;

1) "Delete Selected" function: for IP devices that are not available; usually to remove the IP
device from the management software.
3.6Delete all
Note: Delete all online devices used across the gateway; usually to adjust the management
device for re-operation;

1) "Delete All" function: clear all the devices in the management; usually adjust the
management device to re-add operations;
3.7Export out
Note: For the data export on the network device, the Excel mode is formed; the export mode is
optional;

1) "Export all data" function: Export all the device data in "Cross-Gateway Usage": IP, status,
software and hardware version, computing power, etc. into Excel format;
2) "Export filtered data" function: Export all online device data, usually export data to view;
3.8Monitor
1) Device Monitoring function: IP and MAC address monitoring for a specific device, usually
communicated with the hard reset button of the power board (reset button on the control
panel).This function displays the IP and MAC address when the reset button is pressed.
4.Network opening
4.1Scanning on the network device
Operation steps: Click on "EbiteMinerMini" software - select "LAN management" - view all
devices on the network (at the same time you can operate the DHCP function, which is used
according to the site environment);

Note: Under normal circumstances, all devices connected to the LAN can be read out, some of
them are slow to go online, and can be refreshed several times to try; when the device is
initialized, it is recommended to enable DHCP after the read is successful; Turn off the DHCP
function of the device and configure the static IP (to prevent the IP address from re-matching
after the power-off and restart). For details about the network opening, please refer to the
document "Wingbit-type network configuration operation manual".
4.2Gateway configuration
Step 1: Click on "EbiteMinerMini" software - select "Gateway managment" - select "Network
Segment Import" in the software "Import Device" - import all devices that need to be online

Note: Please ensure that the network is unblocked before networking. As shown in the figure
above, after the configuration of Network Segment Import is completed, all imported devices will
be displayed, and the refresh will be successful and all device related information will be
displayed. At this time, you can select some (or all) devices; select "Mine Pool Configuration" in
"Device Configuration" to configure the next step.
Step 2: Select the “Mine Configuration” function—Select “Mine Pool Configuration”—Start the
Mine Pool Miner Configuration—Enter a valid master and reserve pool

Note: After the configuration of miners in the mine is completed, it can be refreshed many
times,then you can check whether the account has power calculation.
4.3Background management
Note: For the management operation and device status check of a single device, it is easy to
troubleshoot the device failure; enter the device IP address in the browser page to log in to view
(user name: admin password: admin)
5.Fault Maintenance
5.1Calculation is abnormal
Note: The calculation is abnormal, there are many possibilities: fan failure, over temperature,
frequency reduction, power board failure, poor channel contact, etc. When a fault occurs, you
can import the device in Cross-Gateway Usage to view the overall status of the device. If it is
determined that the power is not refreshed multiple times, you can perform the above
troubleshooting.
1) Fan failure; usually two fans operate online, and the network management assistant
provides fan speed information, usually the fan speed is almost the same. If a certain fan speed is
0, there is an individual fan damage failure;

2)If the temperature is too high, the frequency is reduced. Normally, when the temperature
is too high, an over temperature alarm will occur in the small network assistant. As shown in the
temperature, the operating temperature of each power board is displayed. If an alarm is
generated and is not processed for a long time, the frequency of the equipment will decrease,
resulting in a failure of the equipment to meet the standard calculation.

3)Normally, the calculation board is running normally. Every two-way channels"average


arithmetic" is a calculation board. When the capacity calculation is running smoothly, the
calculation data is not much different.However, if there is a single channel(usually one calculation
board will have two average calculation channels) or a set of (two-way channels)calculation is 0,
maybe there is a calculation board channel damage, or the cable is not inserted securely (Red
and white wire between the control board and the calculation board), one calculation board
damage.At this time, it should be checked according to the field equipment;
Note: please referance following picture.At present, our E9i (13.5T) miner contains 4
calculation boards, E9.3 (16T) equipment contains 6 calculation boards, and the network
management assistant displays the "average arithmetic" position as a calculation board. E9i
occupying the first 4 calculations board, “Average arithmetic” 5 and 6 are reserved. The E9.3
device occupies 6 “Average arithmetic” displays.

4) Poor channel contact


Generally, when the contact of the calculation board channel is poor, the single or two
channel calculation of the average calculation will be lower than the normal average. According
to the analysis of the scene environment, when the power is not refreshed multiple times, the
calculation board channel problem can be preliminarily judged;

5.2the mine pool connection is abnormal


Note: When the mine pool connection is abnormal, the main performance is that the mine
machine shows normal operation status in the network management assistant. When the
equipment generates calculation and related information, the account has no display power; at
this time, it is recommended to replace the mine pool and miner number;

5.3the calculation display is abnormal


Note: The average calculation usually shows up, but the calculation of 5 seconds and 60
seconds is 0, which can be solved by upgrading the device software;

5.4Device communication is abnormal


Note: Usually, the device IP can be pinged or cannot be pinged normally. The ping can be
performed normally in the "Cross-Gateway Usage". In this case, it can be normally brushed out in
"LAN management". Or perform initial configuration, or select the device, open DHCP to obtain
the new IP address information of the device, and re-configure the line; if the device cannot be
pinged normally, the device can be directly connected to the computer for spelling test. If the
physical connection is faulty, you can check whether the Ethernet interface indicator of the
device is normal, or you can determine the fault of the device.

6.Software upgrade
6.1upgrade view

6.2 function view


Steps: Select the device to be upgraded - select the "Equipment Management" function -
select "Software Upgrade"

6.3extract the file


Operation mode: set the local communication IP—open the TFTP server—select the file
(extract the upgrade package provided by the engineer)
Note: The local communication IP should be set to the communication IP of the PC service. The
upgrade program needs to be upgraded after confirmation with our technical or R&D personnel.