Retaining Wall With Surcharge PDF
Retaining Wall With Surcharge PDF
@ Bhagalpur
0m
Toe 0 Heel
m
1.2 m
The net pressures, acting upward, are obtained by reducing the uniformly distributed
self weight of the toe slab from the gross pressures at the base. 0.3
Self weight loading = 11.25 kN/m2 0.475 m 0.6
m m
Effective depth 'd' = 365 mm
Vu = 1.5 x (28+19)/2 x (0.475-0.365) = 3.8 kN/m 11.25 39.03
Mu = 1.5 x [(19x0.475x/2)+(28-19)x0.5x0.475x0.475x2/3] = 4.2 kN-m/m kN/m2 kN/m2
Bar Dia = 10 mm
Spacing Required = 327 mm
Provided Spacing = 150 mm
Provide
10 dia @150C/C near front face and In the lowermost one-third height of the wall
10 dia @300C/C near rear face
10 dia @300C/C near front face and In the midlle one-third height of the wall
10 dia @600C/C near front face and
10 dia @450C/C near front face and In the top one-third height of the wall
10 dia @900C/C near front face and
Design Of Retaining Wall
@ Bhagalpur
SUMMARY 0 mm
300 mm
Fck = 25 N/mm2
Fy = 500 N/mm2
Depth of foundation = 0.01 m Y10 @ 450 mm C/C Y10 @ 900 mm C/C 200
Thickness of Base Slab = 450 mm mm
Stem Thickness Bottom = 300 mm Y12 @ 450 mm C/C
Stem Thickness at Top = 300 mm
450
mm
Y10
Y10 @ 150 mm C/C 0 mm
0 0
mm mm
1200
mm