Masshunter Gc/Ms Acquisition Software Version 10.0 Sr1 GC, CTC, HS, QP, and Ms Software/Firmware Revisions

This document summarizes the current software and firmware revisions for Agilent GC/MS acquisition software version 10.0 SR1. It lists the versions for GC drivers, GC firmware, CTC software and firmware, headspace software and firmware, quickprobe software, MS firmware, and other software components that are required to be at or above the versions specified.

Uploaded by

infinity1200
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
50% found this document useful (2 votes)
986 views3 pages

Masshunter Gc/Ms Acquisition Software Version 10.0 Sr1 GC, CTC, HS, QP, and Ms Software/Firmware Revisions

This document summarizes the current software and firmware revisions for Agilent GC/MS acquisition software version 10.0 SR1. It lists the versions for GC drivers, GC firmware, CTC software and firmware, headspace software and firmware, quickprobe software, MS firmware, and other software components that are required to be at or above the versions specified.

Uploaded by

infinity1200
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 3

4/28/2020 CurrentSoftwareFirmwareRevisions-en.

htm

MassHunter GC/MS Acquisition Software Version 10.0 SR1


GC, CTC, HS, QP, and MS Software/Firmware Revisions
GC Software (Driver, Firmware, Components)
· The following GC drivers and related components are distributed on the GC/MS Acquisition
Software Installation disk and installed along with GC/MS Acquisition software.
GC Software Version
Agilent GC Drivers for MassHunter (8890/8860,7890/7820,
3.1.199
6890N/6850 and Intuvo 9000)
6890 GC Control S/W for MassHunter B.01.03
Parts Finder A.01.05
GC Firmware Update Tool 2.1.0.22

· The GC firmware is included with the GC Firmware Update Tool, which is installed along with the
GC/MS Acquisition software.
· The GC firmware version must be the appropriate version listed below or later.

Part Number GC Model GC Firmware


G8890A 8890 2.0.0.391
G8860A 8860 2.0.0.391
G3950A Intuvo 9000A 2.0.0.391
G3440A 7890A A.01.16
G3440B 7890B B.02.05
G4350A 7820A A.01.12.005
G3440B 7810 (5975T) A.03.04.007
G1530N 6890N N.06.07

Part Number Sampler Model Sampler Firmware


G2613A 7683 Autoinjector module A.10.07
G2913A 7683B Autoinjector Module A.11.03
G2614A 7683 Autosampler tray module A.02.01
G3430A 7693A ALS Controller A.02.17
G4513A 7693A Injector A.10.08
G4514A 7693A Tray A.10.16
G4515A 7693A BCR/Mixer A.10.05
G4520A 7693A Tray/heater/barcode A.10.16
G4567A 7650A Autoinjector A.10.02
G4370A/G4370M 7667A Mini Thermal Desorber A.03.09

CTC Software
· The CTC drivers are distributed on separate disks from the MassHunter Acquisition software.
· The CTC firmware must be the appropriate version listed below or later and are also distributed on a
separate disk.
file:///E:/CurrentSoftwareFirmwareRevisions-en.htm 1/3
4/28/2020 CurrentSoftwareFirmwareRevisions-en.htm

PAL 3
Part Number PAL 3 Software PAL 3 Driver Version
G7388AA PAL 3 Control S/W for MassHunter 2.1
Not Available PAL 3 Control S/W for MassHunter 2.1
(Upgrade)

Part Number PAL 3 Model PAL 3 Firmware


G7370A Agilent GC PAL 3 Sampler (RTC) 2.4.5 (2.4.18221.0724-
C34414)
G7367A/G7368A Agilent GC PAL 3 Sampler (RSI) 2.4.5 (2.4.18221.0724-
C34414)
G7366A Agilent GC PAL 3 Sampler (LSI) 2.4.5 (2.4.18221.0724-
C34414)

PAL XT
Part Number PAL XT Software PAL XT Driver Version
G9257AA PAL XT Control S/W for B.01.08
MassHunter
G9256AA PAL XT Control S/W for B.01.08
MassHunter (Upgrade)

Part Number PAL XT Model PAL XT Firmware


G650{1/2/9}B Agilent GC PAL XT Sampler (LAN) 4.3.0
G650{0/1/2/9}-CTC CTC PAL Sampler (RS-232) 2.6.8

Headspace Software
· The Headspace drivers are distributed on separate disks from the MassHunter Acquisition software.
· The Headspace firmware must be the appropriate version listed below or later and are also
distributed on a separate disk.
Part Number Headspace Software HS Driver Version
G7319AA Headspace Control S/W for GC B.01.07.3
MassHunter
G1639AA Headspace Control S/W for GC B.01.07.3
MassHunter (Upgrade)

Part Number HS Model HS Firmware


G4557A Agilent 7697A Headspace Sampler A.01.06
G1888A Agilent G1888 Headspace Sampler A.01.10

QuickProbe Software
· The QuickProbe control driver is distributed on a separate disk from the MassHunter Acquisition
software.
Part Number QuickProbe Software QP Driver Version
G3971AA QuickProbe Control Driver 1.0

file:///E:/CurrentSoftwareFirmwareRevisions-en.htm 2/3
4/28/2020 CurrentSoftwareFirmwareRevisions-en.htm

MS Firmware
· The MS firmware version must be the appropriate version listed below or later.
· The MS firmware is included as part of the MassHunter GC/MS Acquisition Software installation
and is loadable via the GCMS Instrument Configuration program.
MS Model MS Firmware
5973 Single Quad 7.02.29
5975/5975T Single Quad 7.02.29
5977 Single Quad 6.00.34
7000 Triple Quad G.7000.058A
7010 Triple Quad G.7000.058A
7200 Q-TOF G.7200.01.22B
7250 Q-TOF G.7250.02.02Q

Other Software Components


· The Other Software Components are distributed on separate installation media.
Part Number Component Software Package Version
G4600-64006 GC and GC/MS User Manuals and Tools B.01.19

G1701-60175 GC/MS Software Information and Manuals B.10.00

file:///E:/CurrentSoftwareFirmwareRevisions-en.htm 3/3