QA Series: Addressable Fire Alarm Systems

The document describes an addressable fire alarm system module series called QA17. It includes control, output, monitor, and isolator modules. The modules have low power consumption, easy installation, and separate input/output contacts. The control module controls inputs and outputs for various systems like fire alarms, smoke evacuation, and doors. The output module provides higher current to devices like evacuations. The monitor module receives signals from external devices to confirm conditions. The isolator module isolates zones from the control unit during external faults.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
0% found this document useful (0 votes)
259 views1 page

QA Series: Addressable Fire Alarm Systems

The document describes an addressable fire alarm system module series called QA17. It includes control, output, monitor, and isolator modules. The modules have low power consumption, easy installation, and separate input/output contacts. The control module controls inputs and outputs for various systems like fire alarms, smoke evacuation, and doors. The output module provides higher current to devices like evacuations. The monitor module receives signals from external devices to confirm conditions. The isolator module isolates zones from the control unit during external faults.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 1

QA Series

Addressable Fire Alarm Systems

QA17-A
QA17-H QA17-K
QA17-B

Module Series
Characteristics
n Low power consumption in monitoring mode, smoke evacuation, sprinkler, foam , winding
high stability. door...etc.)
n Easy installation, either single module installation n Output module QA17-A can directly connect with
or several modules installed on a special mounting power source. The output voltage from N.O. & N.C.
bar. Implanted type gang box is available to suit will be the same as input voltage.
the decoration design.
n Monitor module QA17-K is designed to monitor
n The Module is designed with separate input and security condition, such as water supply, pump ac-
output contacts to decrease the difficulty of mov- tion ...etc.
ing external wiring.
n Control Module QA17-B is designed to control Approvals:
input & output for all kinds of systems. (fire alarm,

Specifications
Model QA17-K QA17-B QA17-A QA17-H
Type Monitor Module Control Module Output Module Isolator Module
Confirmation of external Input & Output for all Supply higher current such Isolate from control unit
Purpose
signal systems as evacuation when external fault
Receive activation signal Series with conventional
System Connected Series with QA17-B Series with all system zone
from external device detector
Input Source Activation signal Loop signal 24VDC / 110VAC / 220VAC Zone short circuit
COM. N.O. N.C.
1 in 2 out COM. N.O. N.C.
Output Contacts/Load N/A 4A @30VDC, N/A
1.5A @30V DC
2.5A @ 250VAC
EOL Resistor 10kΩ 10kΩ N/A N/A
Address Coding Binary Binary N/A N/A
Ambient Temp. 0°C ~ +50°C
Material Fire-proof plastic
Color Green
Dimensions (mm) H x W x D 55 x 28 x 16 60 x 76 x 31