CAPACITACIÓN

SYSCOM
REFRESH 2020
TAM North-West Cesar Macias

TM

© 2019 Panduit Corp. All Rights Reserved 1


TM

Agenda del día


• Overview Panduit
• Unidades de Negocio.
• Organigrama Panduit México.
• Garantía Panduit.

• Tendencias Tecnológicas
• Soluciones Diámetro reducido
• Nuevos organizadores Alta Densidad & Solución en Blanco
• Actualización de soluciones de Cobre
• Actualización de soluciones de Fibra Óptica
• Arquitecturas de Cableado y Administración en Racks
• Arquitecturas de cableado por zonas.
• Gabinetes y Sistemas de Confinamiento Panduit
• Plataformas de Monitoreo y Gestion de Centros de Datos
• Tool Quick Reference & App INSTALL-IT

© 2019 Panduit Corp. All Rights Reserved 2


TM

Panduit Overview
Market Leadership
+$1.3 BILLION
NET SALES

5,000+EMPLOYEES

9 COUNTRIES
MANUFACTURED IN

60 YEARS OF
INNOVATION 2K
> GLOBAL
PATENTS
PRIVATELY
HELD
9 COUNTRIES
WAREHOUSED IN

4,000,000 FT 2

90% 10 Top 3
of TOP 100 100 of TOP 10 GLOBAL CABLE / CONNECTIVITY

© 2019 Panduit Corp. All Rights Reserved 3


TM

Panduit Overview
Market Leadership MANUFACTURING
LOCATIONS
WAREHOUSE
SITES
SALES
OFFICES
NON-SALES
OFFICES
CUSTOMER BRIEFING
CENTERS
RESEARCH &
DEVELOPMENT

9 Manufacturing Locations
9 Warehouses
37 Sales & Non-Sales Offices
6 Customer Briefing Centers
1 Research & Development
500 Sales & Technical

© 2019 Panduit Corp. All Rights Reserved 4


TM

Panduit Overview
Market Leadership LATIN AMERICA

2 Manufacturing Locations
MEXICO
1 Warehouse
5 Sales & Non-Sales Offices

COSTA RICA

COLOMBIA

MANUFACTURING WAREHOUSE SALES NON-SALES CUSTOMER RESEARCH &


© 2019 Panduit Corp. All Rights Reserved LOCATIONS SITES OFFICES OFFICES BRIEFING DEVELOPMENT
5
CENTERS
TM

Network Infrasetructure MÉXICO


Kaleb Avila Garavito
Vice President
LATAM

Jorge
Angélica Miguel Rivera Erick Carmona Jorge Rosas
Sales Manager
Bleizzefer TSE Channel Manager
Oceguera District 1 Sales Manager Distribution
Executive
Assistant

Arturo Maldonado Jorge Sandoval Cesar Macias Perez Neyton Avila Giovanni Solis
Territory Account Territory Account Manager Territory Account Manager Channel Manager
TSE
Manager Center - SO Bajio NorthWest Distribution

Edgar Arzaluz Carlos Valenzuela


Marco Damian Territory Account Manager
Territory Account Territory Account Manager
NorthEast NorthWest
Manager Center - SO

Juan José García Marcelino Vazque


Gabriela Hernandez Territory Account Manager Territory Account Manager
Territory Account NorthEast Pacific
Manager Center - SO

Rodrigo Jimenez
Territory Account
Manager Center - SO

© 2019 Panduit Corp. All Rights Reserved 6


TM

INSIDE SALES
TEAM LATAM

MÉXICO

Dulce Gonzalez
Mex / EDI Sureste

Rodolfo Neira
EDI Norte

Alan Prieto
Pacifico y Bajío

© 2019 Panduit Corp. All Rights Reserved 7


TM

LATAM

AREAS DE SOPORTE
EDI Latinoamerica
EDI - LATAM

Techsupport LATAM
techsupportlatam@panduit.com
01-800-969-4200

Customer Service LATAM

© 2019 Panduit Corp. All Rights Reserved 8


TM

Garantía Panduit

Programa de garantía
Certificación Plus, Sistemas TX
‒ 25 años de garantía como esta definido en los
estándares ISO-IEC 11801, ISO 8877, EIA/TIA 568-C,
569-B, 606-A, cubriendo desempeño, conectividad,
cable y mano de obra
‒ Garantía basada en leyes mexicanas otorgada
directamente por Panduit Mexico al cliente
‒ Único punto de contacto
‒ Protección a la inversión, ya que esta diseñada no solo
para soportar requerimientos actuales, sino también
para necesidades futuras.
‒ Soluciones garantizadas para VoIP
© 2019 Panduit Corp. All Rights Reserved
‒ Soluciones probadas Pan-Lab
9
TM

Infraestructura para aplicaciones críticas

IC/MRO OEM Enterprise Data Center Industrial

El portafolio más Amplio de la industria soportado por un ecosistema Global


© 2019 Panduit Corp. All Rights Reserved 10
TM

Industrial Construction & MRO

© 2019 Panduit Corp. All Rights Reserved 11


®
TM

Industrial Construction & MRO

Safety Power
Connectors

Grounding
Connectors Cable Ties

© 2019 Panduit Corp. All Rights Reserved Back to home screen12


TM

Original Equipment Manufacturers (OEM)

© 2019 Panduit Corp. All Rights Reserved 13


®
TM

OEM

Cable Wiring Duct


Management

Installation Tools Safety


© 2019 Panduit Corp. All Rights Reserved Back to home screen14
TM

© 2019 Panduit Corp. All Rights Reserved 15


TM

© 2019 Panduit Corp. All Rights Reserved 16


TM

Panduit´s Experience Center Chicago


TM

Tendencias Tecnologicas
TM

Las redes Inalámbricas continuarán


... pero ¿será 5G o Wi-Fi 6?

© 2019 Panduit Corp. All Rights Reserved 19


TM

Cosas que debe saber sobre 5G y Wi-Fi 6


La cantidad total de tráfico de Internet de 2017-2022 será
mayor que en los 32 años anteriores del Internet. Wi-Fi
será el mecanismo de transporte para más de la mitad de
ese tráfico. Además de desafíos existentes de ancho de
banda, se espera que una afluencia de nuevos dispositivos
móviles con Wi-Fi 6 llegue a las redes a fines de 2019 y
2020.
ü Traen la misma promesa de un rendimiento
dramáticamente mejor
El video 4K ya desafía las redes con un rendimiento de
15 a 18 Mbps, pero 8K la transmisión de video también
está en línea, y consume aproximadamente 1 Gbps de ü ¡Coexistirán!
rendimiento. Las aplicaciones de realidad virtual
aumentada tendrán un uso cada vez mayor y consumirán ü Wi-Fi seguirá siendo la opción preferida para redes en
desde 600 Mbps a 1 Gbps de tráfico. interiores

Estos nuevos desafíos de ancho de banda requerirán


ü 5G será la primera opción para redes al aire libre
velocidades de conexión Wi-Fi en todo el mundo para
aumentar 2.2x entre 2017 y 2022.
ü ¡Wi-Fi 6 ya está disponible!
© 2019 Panduit Corp. All Rights Reserved 20
TM

Comparación inalámbrica estándar


Wi-Fi 7
Traditional Name 802.11n 802.11ac 802.11ax 802.11be
Wi-Fi Alliance
TBD
Certification Mark
2.4 and 5 GHz
Bands 2.5 or 5 GHz 5 GHz 2.4, 5, and 6 GHz
6 GHz Compatible

Data Rates (Max) 576 Mbps 6933 Mbps 9607.8 Mbps > 10 Gbps
Spatial Streams 4 8 (unlikely > 4) 8 TBD
Beamforming Yes Yes Yes Yes
Cabling Reqs Category 6 Category 6A Category 6A 2x Category 6A
PoE Reqs (Full) 802.3af 802.3at Yes Yes
PoE Reqs
- - 802.3bt 2x 802.3bt
(enhanced)
© 2019 Panduit Corp. All Rights Reserved 21
TM

Wi-Fi 6 Ventajas sobre Wi-Fi 5


• Las velocidades de datos del dispositivo final mejoraron la velocidad de hasta 4 veces

• Mayor capacidad

• Rendimiento mejorado en entornos con muchos dispositivos.

• Mayor duración de la batería para dispositivos finales

• Latencia reducida a menos de 1 ms

© 2019 Panduit Corp. All Rights Reserved 22


TM

OFDM vs OFDMA
• OFDMA utiliza de manera
más eficiente el ancho de
banda

• Los usuarios utilizan los


canales de manera más
eficiente

• Utilizando 96% versus


52% de espacio

• Mejora el rendimiento
mientras reduce la
© 2019 Panduit Corp. All Rights Reserved latencia 23
TM

Realidades en 5G: Tasa de adopción 400Gbps 15 millones de puertos para 2023


Se espera que la llegada de los transceivers ópticos 400G sea de 1 millón para 2022.
Las soluciones de fibra multimodo (dúplex y paralelo) estarán listas antes de mediados de 2020

Ports

40G
400G switch ports

100G

2016 2017 2018 2019 2020 2021 2022

Source: Dell’Oro Group July 2018 Ethernet Switching Forecast

© 2019 Panduit Corp. All Rights Reserved 24


TM

Fibra Óptica para 5G


Emb at 850 nm EMB at 953 nm
Fibre Type (MHz-km) (MH-km)

OM3 2000 NA

OM4
OM1
4700
OM2 NA
OM2+ OM3 OM4 OM4+ OM5 OM5+
OM5 4700 2470
Legacy Legacy ‘Enhanced’ LOMMF ‘Enhanced’ Chromatic WBMMF Chromatic
Dispersion compensating OM4+ 62.5/125um
5500 50/125um 2000 50/125um 50/125um LOMMF Dispersion Dispersion
Corrected Corrected
OM4 OM5

Signature Core
Las demostraciones en Ethernet Alliance
2017-2018 muestran la ventaja de la fibra de OM1 OM1 OM1
compensación de dispersión OM2+ OM4 OM5

OM1 OM1 OM1


OM3 OM4+ OM5+

1989 1998 2002 2009 2015

Panduit ha sido líder en esta evolución, descubriendo el efecto de la dispersión cromática para
velocidades de datos superiores a 10, 40, 100, 200 Gbps:
Introdujo productos OM4 + en 2011
© 2019 Panduit Corp. All Rights Reserved
Introdujo productos OM5 + en 2017 25
TM

Recomendaciones TIA-4966 para redes inalámbricas


• TSB-162-A (Telecommuncations Cabling Guidelines
for Wireless Access Points) se desarrolló como guía
de instalación y cableado de WAPs

• La ubicación de cada WAP debe contar como MÍNIMO


con un cable horizontal– se recomiendan DOS cables
por WAP

• La recomendación es usar cable Categoría 6A en


todas instalación nueva

© 2019 Panduit Corp. All Rights Reserved 26


TM

Redes inalámbricas: Estándares Relacionados


– IEEE 802.11n:
• Aprobado en 2007 pero los productos se introdujeron al mercado hasta el 2009.
• Trabaja en las frecuencias de 2.4GHz y 5GHz.
• Soporta velocidades de hasta 600Mbps.
• Es el estándar más utilizado en este momento.
• Es compatible con las versiones anteriores 802.11b/a/g.
– IEEE 802.11ac:
• Aprobado en junio 2013 y los productos se introdujeron al mercado inmediatamente.
• Trabaja en la frecuencia de 5GHz.
• Soporta velocidades de hasta 6.9Gbps.
• Es el estándar en el que se están enfocando los fabricantes en este momento.

© 2019 Panduit Corp. All Rights Reserved 27


TM

¿Qué es la infraestructura hiperconvergente?


La infraestructura hiperconvergente combina hardware de centro
de datos común utilizando recursos de almacenamiento conectados
localmente con software inteligente para crear bloques de
construcción flexibles que reemplazan la infraestructura tradicional
que consiste en servidores, redes y almacenamiento separados.

© 2019 Panduit Corp. All Rights Reserved 28


TM

El creciente papel de la HCI en los Centros de Datos


La HCI desempeña un papel clave en la estrategia en la nube
La HCI es una ruta que las P: Indique el estado de adopción de infraestructura hiperconvergente (por
ejemplo, Nutanix, VMware VSAN) por parte de su organización.
organizaciones pueden seguir P: ¿Qué papel desempeña la infraestructura hiperconvergente en su
para ayudar a modernizar sus organización? Seleccione todas las respuestas válidas.
entornos de TI y simplificar tanto
la implementación de la
infraestructura como su continua
gestión. En la encuesta VotE:
Storage Workloads and Key
Projects, el 53 % de los
encuestados indicó que ya usan
HCI o planean usarla en los
próximos dos años, y otro 19 % lo
está considerando aunque aún no
esté en su plan actual.

© 2019 Panduit Corp. All Rights Reserved


Fuente: 451 Research’s Voice of the Enterprise: Storage, Workloads and Key Projects 2018
29
TM

¿Qué sucede en los Centros de Datos con la


adopción de ecosistemas HCI?
AHORA Conectividad Monitoreo
La infraestructura toma relevancia de
manera crítica, ya que todos los • Energía
elementos que integran las soluciones (PDU´s)
HCI se concentran en un solo Gabinete HCI
de Alta Densidad de Cómputo, • Temperatura
Almacenamiento, Red y Conectividad (Sensores)
por lo que el monitoreo permanente es
necesario adoptando las • Equipo
recomendaciones de las normativas y
estándares internacionales. PUE (Power
Usage
TIA-942 Estándard Data Center Effectiveness)

ASHRAE
© 2019 Panduit Corp. All Rights Reserved HCI = Cómputo + Redes + Storage + Conectividad 30
TM

Explicación de Edge Compute

En esencia, Edge Compute es un cambio de un modelo de cómputo centralizado a un modelo de


cómputo híbrido distribuido. Que significa esto exactamente? Durante los últimos 20 años más o
menos, el modelo informático se ha centralizado casi estrictamente. Si su empresa utilizó un centro de
datos local, cómputo en la nube o modelo de nube híbrida, es un modelo de cómputo centralizado.
Todos los datos son procesados y almacenado en una ubicación central (es decir, centro de datos
locales, centro de datos en la nube, etc.). Edge Compute está complementando ese modelo con más
recursos de cómputo en el borde o más cerca del usuario final.

El líder de la industria Rajashree Rao define sucintamente Edge computing como:

“La práctica de recopilar y analizar datos donde se generan, en los bordes de la red". *
© 2019 Panduit Corp. All Rights Reserved 31
TM

CDN the Original Edge Compute Application


Las redes de entrega de contenido o CDN son un servicio que usted aprovecha cada vez
que mira un video o descarga algo desde Internet o su plataforma de redes sociales favorita.
Con una CDN, el contenido se carga en un servidor de origen, después de lo cual la CDN lo
distribuye a todos los puntos de presencia (PoP) en el CDN. Una vez distribuido, los
usuarios finales extraen el contenido del sitio más cercano. CDN PoP, en lugar del servidor
de origen.

With CDN

© 2019 Panduit Corp. All Rights Reserved 32


TM

Modelos de
Arquitectura
de Referencia
para
ecosistemas
Edge
Computing

© 2019 Panduit Corp. All Rights Reserved 33


TM

Micro Data Center

(Disponible
solo para
MDC82NN
México)
© 2019 Panduit Corp. All Rights Reserved 34
TM

Problema: Ciudades que enfrentan retos reales


Población 9.7 billones de
personas para 2050

Incremento de gente
Urbanización viviendo en las
ciudades de 50% a
66% para 2050 (2.5b)

Estrés en la
Recursos Limitados infraestructura:
energía, agua,
movilidad
© 2019 Panduit Corp. All Rights Reserved 35
TM

Definición
Una ciudad inteligente pone a las personas en el centro del desarrollo,
incorpora las tecnologías de la información y la comunicación en la
gestión urbana y utiliza estos elementos como herramientas para estimular
el diseño de un gobierno que incluye la planificación colaborativa y la
participación ciudadana. Al promover un desarrollo integrado y sostenible, las
ciudades inteligentes se vuelven más innovadoras, competitivas,
atractivas y resilientes, mejorando así las vidas de sus habitantes.
*BID

© 2019 Panduit Corp. All Rights Reserved 36


TM

Definición Una ciudad inteligente no es un proyecto


tecnológico, es un proyecto de ciudad:
• De mejora de la movilidad
• De mejora de los servicios públicos
• De facilidades para el desarrollo de iniciativas
privadas de servicios
• De mejora de la eficiencia
• De mejora de la seguridad

Que usa las Tecnologías de Información como


catalizador:
• Disponibilidad de mejores comunicaciones
• Ancho de banda, cobertura y conectividad
• Menor costo
• Incorporable a todos los servicios
• Estándares

© 2019 Panduit Corp. All Rights Reserved 37


TM

Componentes de
una Ciudad
Inteligente

© 2019 Panduit Corp. All Rights Reserved 38


TM

Papel de la infraestructura en las Ciudades


Inteligentes
Dado que la utilización de las tecnologías de información es fundamental para
poder hablar de ciudades inteligentes, de igual manera la infraestructura es la
base para poder conectar todos los sistemas y transportar la información
adecuadamente. Algunos de los componentes principales de las CI son:

Edificios Digitales Edge Computing / DC


5G / Inalámbrico
© 2019 Panduit Corp. All Rights Reserved 39
TM

Estándar Categoría 8
• IEEE 802.3bq Publicado en Septiembre 2016
‒ 25 and 40GBASE-T a través de Cat 8

• Cat 8 publicado en Julio de 2016


‒ TIA-568-C.2-1
‒ Únicamente blindado

• Canal de 30 metros
Canal Cat 6A
• 24m link, 6m Patch cords

• Conector RJ 45
Canal Cat 8
• 2000 MHz ancho de banda, terminable en
campo, se puede probar.

© 2019 Panduit Corp. All Rights Reserved 40


TM

Descripción general de las


actualizaciones de estándares de
cobre
• 25 and 40GBASE-T
‒ IEEE 802.3bq
‒ ANSI/TIA-568-C.2-1 (Category 8)

• Power over Ethernet


‒ IEEE 802.3bt (PoE ++)
‒ TSB-184-A
‒ NEC® 2017

© 2019 Panduit Corp. All Rights Reserved 41


TM

¿Por qué instalar Categoría 6A?


TM

Mercado de Categoría 6A & 10G BASE-T


§ 10GBASE-T (10Gbps) será dominante para el 2016
§ 10GBASE-T necesita una infraestructura de cableado Categoría 6A

© 2019 Panduit Corp. All Rights Reserved 43


TM

© 2019 Panduit Corp. All Rights Reserved 44


TM

Estándares TIA

© 2019 Panduit Corp. All Rights Reserved 45


TM

Aplicaciones PoE

© 2019 Panduit Corp. All Rights Reserved 46


TM

Se recomienda Cat 6A para correr la siguiente


generación de Power Over Ethernet (PoE)
§ Categoría 5E y 6 trabajan bien con PoE and PoE+
§ Categoría 6A es recomendada para PoE++ y las siguientes aplicaciones
Number of
Maximum Power at Power at Maximum Data Standard
Type Standards Energized
Current Source Device Rate Ratified
Pairs

PoE IEEE 802.3af (802.3at Type 1) 350 mA 2 15.4 W 13 W 1000BASE-T 2003

PoE+ IEEE 802.3at Type 2 600 mA 2 30 W 25.5 W 1000BASE-T 2009

PoE++ Proposed IEEE 802.3bt Type 3 600 mA 60 W 51 W


Expected
4 10GBASE-T
1Q2018
(4PPoE) Proposed IEEE 802.3bt Type 4 960 mA 99 W 71 W

Cisco UPOE 600 mA 60 W 51 W Exists today –


No IEEE
4 Varies no official
standard HDBaseT (www.hdbaset.org) 1000 mA 100 W 100 W ratification

Categoría 6A recomendada para nuevos estándares con 49W+ de potencia


© 2019 Panduit Corp. All Rights Reserved 47
TM

Comparación de categorías
TIA Cat 5E Cat 6 “Cat 6A” Cat 8
ISO Class D Class E Class EA Class 8.I

Contrucción UTP or STP UTP or STP UTP or STP STP

Tipo de conector RJ45 RJ45 RJ45 RJ45

Ancho de banda 100 MHz 250 MHz 500 MHz 2000 MHz

Calibre del cable 23/24 AWG 23 AWG 23 AWG 22/23 AWG


PoE Support Yes Yes Yes Yes
Diámetro (Approx) .210’’ .240’’ .280’’ 0.330” (TBD)
Gigabit Ethernet 100 m 100 m 100m 100m
Limited distances per
10GBASE-T Ethernet Not Supported 100m 100m
TSB-155-A
25/40GBASE-T Not Supported Not Supported Not Supported 30m

Costo aproximado
1X 1.2 X 1.5X 3X (TBD)
instalado

© 2019 Panduit Corp. All Rights Reserved 48


TM

Ciclo de vida (años)


Ingenierias de TI
Ciclo de vida (años)
Ingenierias de TI
25

20

15

10

0
Software Equipo Activo Infraestructura física

© 2019 Panduit Corp. All Rights Reserved 49


TM

Relación Costo vs Mbps


Categorías de Cableado Costo Referencia Mbps Relación $ vs Mbps Costo Mbps
Nodo en Cat 6A 400 usd 10,000 400 usd / 10,000 Mbps 0.04 usd
Nodo en Cat 6 230 usd 1,000 230 usd / 1,000 Mbps 0.23 usd
Nodo en Cat 5E 160 usd 100 160 usd / 100 Mbps 1.6 usd

© 2019 Panduit Corp. All Rights Reserved 50


TM

Inversión en infraestructura

7% Infrastructura
20+ años (o para siempre)

60% Software

10% 5 años
2 a 5 años
Operaciones

23% Networking
23% Networking
5 años
5 years

10% Operaciones
5 años
60% Software
2 a 5 años

7% Infrastructura
20+ años (o para siempre)

© 2019 Panduit Corp. All Rights Reserved 51


TM

¿Otra razón para ocupar Cat 6A?


Edificios Digitales
TM

Definición del Edificio Digital Smart


Spaces

API
Applications
API

Control Building Lighting


Systems Management Energy Management
Control All IP Network

Network
Network Infrastructure
Infrastructure
Cisco Switches
• CoAP, PoE, PoE+, UPOE
• Security with ISE
• Converge disparate networks (HVAC,
Sensors metering, lighting) into one IP network

Intelligent
Drivers

LED fixtures/
Components Lighting Sensors Building HVAC IP Video Wi-Fi
(Light, Motion, Automation Surveillance Access
CO2, BTLE) Camera Point

© 2019 Panduit Corp. All Rights Reserved 53


TM

Compañias demandan más de su área de trabajo

§ Personal
§ Versátil
§ Inteligente

§ Menores costos
§ Mejorar la productividad
© 2019 Panduit Corp. All Rights Reserved
§ Optimizar el espacio de oficina
54
TM

La iluminación inteligente transforma las oficinas

La red de sensores y sistemas inteligentes


Sensor network and operating system enables
permiten:
Application
§ Mejorar platforms
productividad
Enhanced
§ Áreas lighting al máximo
aprovechadas
More intelligent
§ Plataformas network
de aplicación
© 2019 Panduit Corp. All Rights Reserved 55
TM

Puede ayudar a curar e incrementar los ingresos


del hospital

Poder ajustar la temperatura de la


iluminación y mejorar el ánimo.

Aplicaciones podrían mandar pulsos de luz


para ayudar a reducer el ruido en los
pasillos
Incremento en la puntuación del hospital
© 2019 Panduit Corp. All Rights Reserved 56
TM

Puede ayudar a los estudiantes a aprender

Iluminación que se adapta a las


condiciones de la clase.

Utilización de luz blanca por la mañana


para energizer a los estudiantes

© 2019 Panduit Corp. All Rights Reserved


Utilización de luz calida para calmar.
57
TM

Mantener los edificios Seguros

Se puede detectar actividades anormales


en el edificio y notificar a seguridad e
incluso identificarlo con iluminación.
© 2019 Panduit Corp. All Rights Reserved 58
TM

Soluciones de cables de Diámetro Reducido


TM

Retos actuales son los Espacios de


Telecomunicaciones

Organizadores de
Altas densidades de cables Manejadores
puertos congestionados de cable
saturados

Dificultad para Configuraciones


utilizar paneles de que consumen
parcheo de alta mucho espacio
densidad

© 2019 Panduit Corp. All Rights Reserved 60


TM

Cableado: no tocar ese cable

© 2019 Panduit Corp. All Rights Reserved 61


TM

¿Qué quiere decir con que puedo encontrar el


cable?

© 2019 Panduit Corp. All Rights Reserved 62


TM

Administración de cables para mejor


flujo de aire

Todavía hay
espacios
alrededor del
cableado para
el aire.

© 2019 Panduit Corp. All Rights Reserved 63


TM

Calibre 28 AWG para los retos actuales de los


Cuartos de Telecomunicaciones
• Usos en:
‒ Pequeños y congestionados TR’S
‒ Canalizaciones congestionadas
‒ Se requiere agregar nuevo equipo

• Aplicación en sitios nuevos y


existentes

© 2019 Panduit Corp. All Rights Reserved 64


TM

Creciente aceptación del calibre 28 AWG


• Razones Comparación de tamaños

‒ Menor diámetro que el 24 AWG


‒ Trabaja con la mayoría de los
escenarios encontrados en los TR’s
• Resultados
‒ Mayor capacidad, mayor densidad
‒ Mayor facilidad en el manejo de los
cables
‒ Costos menores (CAPEX & OPEX)
Patch cord Patch cord
Categoría 6 Categoría 6
24 AWG 28 AWG
© 2019 Panduit Corp. All Rights Reserved 65
TM

Grupos de cables en los dedos de los


organizadores
Grupo de (24) Patch Cords Categoría 6
24 AWG
1.37” Dia.

1.0”
altura
28 AWG
0.89” Dia.

Grupo de 28 AWG patch cords caben


fácilmente
© 2019 Panduit Corp. All Rights Reserved 66
TM

Capacidad del organizador vertical


Numero de Patch Cords Categoría 6

24 AWG 28 AWG

213 523
cables cables

Caben 146% cables más


© 2019 Panduit Corp. All Rights Reserved 67
TM

Espacio entre cables


• Visibilidad del número del puerto
• Facilidad en el manejo de los cables
‒ Espacio par los dedos y acceso a los plugs
‒ Más claridad en la ruta de los cables
• Mejor flujo de aire & enfriamiento
• Nuevas configuraciones
‒ Menos organizadores horizontales
‒ Uso efectivo de paneles de alta densidad
‒ Permite parcheo directamente al switch

© 2019 Panduit Corp. All Rights Reserved 68


TM

Ejemplo aplicación de cables 28 AWG


Cableado de patch cords 24 AWG vs. 28 AWG<

Configuración con cables 24 AWG


• 768 cables en total
• Múltiples longitudes de cables
• Grandes grupos de cables
• 8RU de organizadores horizontales

Configuración con cables 28 AWG


• 768 cables en total
• Todos los cables del mismo tamaño
• Pequeños grupos de cables
• No se requieren organizadores
horizontales

Nueva configuración con cables 28 AWG


Más de 1 milla de cable 60% menos cable
© 2019 Panduit Corp. All Rights Reserved 69
TM

Nuevos organizadores Alta Densidad


&
Solución en Blanco

Confidential © 2018 Panduit Corp. All Rights Reserved 70


TM

PatchRunner 2 Mejorado (VCM con Parcheo Vertical)


Su principal objetivo, mantener la mejor
funcionalidad de su clase con la optimización de
espacios de la familia PatchRunner 2

§ Cero parcheo en las unidades de rack (RU)


– Espacios para parchar dentro de los organizadores verticales.
– Separación de 6RU a 15RU dentro del canal.
§ La mejor puerta de su clase.
– Doble bisagra, fácil de cerrar.
– Mecanismo de cierre mejorado.
§ Incremento de capacidad de cables
– Gestor más profundo, mayor volumen interno.
– Hasta un 45% más de capacidad que el modelo PR2V.
§ Estética mejorada
– Oferta estándar en blanco y negro.
– Tapas de puerta moldeadas.
§ Pedidos simplificados
– Puertas incluidas.
– Menos números de parte.

– Requiere considerar el montaje en sitio.


*VCM: Vertical Cable Management – Gestión de Cable Vertical.
© 2019 Panduit Corp. All Rights Reserved 71
TM

VCM: Posicionamiento
Telecommunications Rooms Labs / HD Telco Rooms / Data Centers

• Posicionamiento del Producto


‒ NetRunner: Baja densidad,
Económico.
‒ PR2V: High Capacity, Gama
media en precio.
‒ PE2V: Alta densidad, Ahorro en
espacios, Costo Premium.

NetRunner PachRunner 2 PR2V* PatchRunner2


WMPV* Alta Densidad
PE2V*

Capacidad de Cableado
menor a mayor

© 2019 Panduit Corp. All Rights Reserved 72


TM

Oferta de Productos Blancos

• Aspecto limpio y elegante

• Mayor reflexión de la luz

• Ahorro de energía

• Soluciones completas

• Productos estándares

© 2019 Panduit Corp. All Rights Reserved 73


TM

Oferta estándar de productos blancos

Organizadores de
cables horizontales

Accesorios

Organizadores Racks de 4 postes Racks de 2 postes Patch Panels


Verticales

© 2019 Panduit Corp. All Rights Reserved 74


TM

Cero parcheo en UR

• Máxima versatilidad y
resistencia
VCM Width RU in the
‒ Se pueden utilizar accesorios Channel
para soportar diferentes 6” Width 6 RU
configuraciones.
8” Width 9 RU
‒ El canal se puede cerrar para
aplicaciones de pasillo 10” Width 12 RU
frío/caliente. 12” Width 15 RU
‒ El canal puede configurarse
para enrutar fibra o cable.
‒ Soporte de VCM hasta 15RU
de configuración.
© 2019 Panduit Corp. All Rights Reserved 75
TM

Zero RU Applications

Parcheo Vertical HAC w/ pass-thru Barra de alivio Equipo activo con


de tensión. parcheo directo
(SRB) en paneles.
© 2019 Panduit Corp. All Rights Reserved 76
TM

Optimización de espacios consulte a su vendedor

© 2019 Panduit Corp. All Rights Reserved 77


TM

Innovación Vari-Matrix
TM

Cat 6A Panduit Vari-MaTrix Technology

Panduit creo el tape metálico


discontinuo
El mejor en clase para evitar
Alien xtalk
Cables de diámetro reducido
0.28in/7.2m
0.24in/6.2mm

© 2019 Panduit Corp. All Rights Reserved 80


TM

Vari-MaTriX 6A Normal

• El cable Cat 6A más delgado en el mundo


‒ Hasta un 23% más delgado y ligero

• El cable Cat 6A más avanzado


‒ 23 AWG, canal de100m
‒ Rendimiento sobre los estándares
‒ El mejor para mitigar el alien crosstalk
‒ El mejor UTP contra EMI
Vari-MaTriX

© 2019 Panduit Corp. All Rights Reserved 81


TM

Vari-MaTriX Conduit
Cable
Cable Tray
Diameter
3/4" 1" 4" 4"x 12"
• Incrementa la capacidad de11% a 40% 0.250" 4 7 119 484
0.285" 3 5 91 372
• Menos canalizaciones y más pequeñas 0.270" 3 6 98 415
0.265" 3 6 105 430
*40% fill per National Electric Code Guidelines
• Fácil instalación
Vari-MaTriX
‒ Más ligero 7 cables
‒ Más flexible
‒ Radios de curvatura reducidos

• Simplifica el cambio de Cat 6 a 6A

6A Normal
© 2019 Panduit Corp. All Rights Reserved
5 cables
82
TM

Vari-MaTriX – ¿Por qué importa el EMI?

Fuentes emisoras comunes Impredecible


Difícil de diagnosticar

Perdida de paquetes

Blindajes continuos actuan como


antenas

© 2019 Panduit Corp. All Rights Reserved 83


TM

Vari-MaTriX – Comparando los diseños


§ Mitigando el alien crosstalk – todos los blindajes funcionan bien
§ EMI – ¡El diseño del blindaje importa!

§ El efecto Antena compromete el


Blindaje continuo EMI

§ El desempeño EMI mejora mucho


Blindaje Discontinuo
Con segmentos iguales PD
MATRIX

§ El mejor UTP contra EMI


Blindaje Discontinuo
Con diferentes segmentos
© 2019 Panduit Corp. All Rights Reserved 84
TM

Vari-MaTriX – EMI Resultados de pruebas


EMI Source

Blindaje Continuo
Distancia Segura

EMI Source

Vari-MaTriX
Distancia Segura

!Vari-MaTriX es ~2x mejor que los blindajes!

© 2019 Panduit Corp. All Rights Reserved


For more information regarding the Vari-MaTriX and EMI, please see our White Paper
85
TM

Actualización de Productos de Cobre


TM

Jack de temperatura más alta


• Incremento de 65 ° C a 75 ° C

• Temperaturas extremas más


tolerantes en aplicaciones
industriales, exteriores y PoE

• TG y NetKey solamente

• Disponible a mediados de 2020


Ligera diferencia visual

La carcasa de nuestros jacks está hecha con un policarbonato que soporta temperaturas más altas sin deformación.

Esto aumenta el rango de calor operativo de 65 ° C a 75 ° C.

Esto proporciona más margen de protección para aplicaciones como PoE ++ o recintos metálicos para exteriores.
© 2019 Panduit Corp. All Rights Reserved 87
TM

TODOS los conectores Panduit: Diseñados para PoE

Plug Fully Engaged with Jack Plug at Disengagement Point


Jack
Contacts
Plug Contacts Plug
Contacts
Jack Contacts

• El arco eléctrico (chispa) ocurre cuando se quita el enchufe • La acumulación de carbono puede evitar la transmisión
de datos
• No ocurre cuando se inserta el enchufe
• Jack debe estar diseñado para cumplir con IEC 60512-
99-001 para 2A
© 2019 Panduit Corp. All Rights Reserved 88
TM

Líder en Tecnología en los Jacks


100% probados en fabrica y
Terminar 22-26AWG &
con número de serie
Re-terminar 20 times

Forma Tapa de sujeción


Forma
Mini-com para un Rápido &
Mini-com Alto rendimiento

Supresor de arcos de
Supresor
integrados & Tecnología
Tecnología
arcos integrados supresoradedeAlíen
Alíen
operación a 75 °C supresora
& operación a 65 paraCat
Cat6A
6A
para PoE++ para
°C para PoE++
EPD disponible para
Robusto: 1000V, protección de sobre corriente,
Puntos LEED
Compatible con plugs 4 & 6
© 2019 Panduit Corp. All Rights Reserved 89
TM

Certificatión PoE Jack IEC 60512-99-002


• Panduit comenzó a probar nuestros conectores a niveles
de PoE ++ en 2016, incluso antes de que se ratificara la
tecnología.

• El estándar IEC 60512-99 valida que el arco eléctrico no


afecta el rendimiento del Jack

• Las tomas Panduit hacen contacto más allá del punto de


incisión causado por el arco

• Los Jacks Panduit también están diseñados para que la


abrasión entre los contactos elimine la acumulación de
carbono.

© 2019 Panduit Corp. All Rights Reserved 90


TM

Jacks TG, Opciones CAT 6A NUEVO

Salida Lateral
Estándar
CJUD6X88TG**
CJ6X88TG**
CJLR6X88TG**

Compuerta Blindado Blindado Compuerta


CJH6X88TG** CJS6X88TG**Y CJSH6X88TG**Y

© 2019 Panduit Corp. All Rights Reserved 91


TM

Tapas Anguladas

§ Curvas muy ajustadas


§ Placas en muebles, ductos
perimetrales
§ 45° arriba/abajo o izquierda/ derecha

Izquierda/Derecha
Arriba/Abajo en
Muebles y ducto
Placas
Patch Panel Izquierda/Derecha perimetral
© 2019 Panduit Corp. All Rights Reserved 92
TM

Beneficios de las Tapas Anguladas


1.930” Panduit 6A UTP
Cable (0.275”)
Reduce la profundidad en un 36%
Panduit TG Jacks 1.152”

Panduit 6A UTP Cable (0.275”)

2.144”
Panduit TG Jacks 1.366”

Pared de mueble (0.125”)

Placa de pared
CFFP4** (0.400”)

Faceplate CFP4** (0.220”)

Tablaroca(0.625”)

Reduce la profundidad en un 40%


© 2019 Panduit Corp. All Rights Reserved 93
TM

Plug Field Terminated

© 2019 Panduit Corp. All Rights Reserved 94


TM

TX6A™ Field-Term RJ45 Plug


• Conexión directa a WAP, Cámaras,
HDBASE-T, Iluminación IP

• Terminación TG

• Ahorra tiempo, $, asegura el rendimiento

• Estará incluido en la nueva actualización de


la TIA.

Field-Term Plug (FP6X88MTG)


© 2019 Panduit Corp. All Rights Reserved 95
TM

Plug Field Terminated

© 2019 Panduit Corp. All Rights Reserved 96


TM

Cables para exteriores, Planta externa OSP


§ Aplicaciones
– Cámaras de seguridad
– Cableado entre edificios de un Campus

§ Construcción del cable


– Cat6 U/UTP
– Resistente a rayos UV
– Con Gel para prevenir humedad
– Temperatura Operación -40C to 80C

Ø ANSI/TIA-758-B

• Número de Parte
– Global Cat6 PUO6C04BL-U
– Global
© 2019 Panduit Corp. All Rights Reserved
Cat 6A PFO6X04BU-CEG
97
TM

Direct Attach Copper SFP+ (10 Gb)


or
QSFP+ (40 Gb)
• DAC (Direct Attach Copper)

• High Speed

• Twinax

• SFP+ (Small Form-Factor Pluggable)


¡Todos significan lo mismo!

Los cables Panduit DAC pasivos y activos de conexión directa Panduit® SFP+
10Gbps son MSA, SFF-8431, cumple con SFF-8432 y SFF-8472, lo que significa
que son compatibles con todos los equipos activos con puertos MSA compatibles.

https://www.panduit.com/content/dam/panduit/en/products/media/2/92/092/4092/101384092.pdf
© 2019 Panduit Corp. All Rights Reserved 98
TM

SFP28 DAC ¿Qué es el cable SFP28?


El cable SFP28, también conocido como cable Twinax
SFP28 DAC (Direct Attach Copper) o cable SFP28
AOC (Active Optical Cable), es una forma de cable de
• IEEE 802.3 by compliant (25GbE) alta velocidad con conector SFP28 en cada extremo.
Cuenta con un menor consumo de energía y una
menor pérdida de interconexión, lo que lo hace
• Compatible con equipos 10GbE adecuado para la conmutación TOR (Top-of Rack) a la
conectividad del servidor.
• La manga color gris indica SFP28

• Número de partes:
‒ PSF2PXA1MBL
‒ PSF2PXA2MBL
‒ PSF2PXA3MBL

© 2019 Panduit Corp. All Rights Reserved 99


TM

Direct Attach Cables

Cable twinax de alta


velocidad con conectores
modulares SFP+
(10Gbps, 25Gbps) en
cada extremo.

Compatibles con casi


todas las marcas de 30 AWG 30 AWG
Switches, Servidores,
SFP+ a SFP+ (10Gbps) SFP28 a SFP28 (25Gbps)
Routers, Firewalls.
PSF1PXAXX PSF2PXA2MBL

© 2019 Panduit Corp. All Rights Reserved 100


TM

Soluciones de Fibra Optica

Confidential © 2018 Panduit Corp. All Rights Reserved 101


TM

Tipos de Fibra Óptica


Monomodo Multimod
9/125µm o
50/125µ
m

Multimodo
62.5/125µ
m

9% 8% 8% 10
%
Multimodo

Monomodo

© 2019 Panduit Corp. All Rights Reserved 102


TM

Tipos de Cables de Fibra Óptica


Clasificación por ambiente de uso:
Clasificación por protección mecánica:
• Interior - Con armadura (para enterrado directo)
o Grado de flamabilidad de la - Sin armadura (requiere un elemento
chaqueta (riser, plenum, LSZH) de protección como una tubería)
o Construcción Tight buffer
• Exterior
o No requieren cumplimiento de
flamabilidad
o Construcción loose tube
o Protección humedad (Panduit no
gel)
• Interior y exterior
o Requieren cumplimiento de
flamabilidad
o Construcción loose tuve
o Protección Humedad

© 2019 Panduit Corp. All Rights Reserved 103


TM

Aplicaciones típicas de la fibra en la


empresa Entrada/Demarcación/Red del operador
• Cables de interior/exterior
Cableado principal MDA • Cables de planta externa
• Cables de distribución Cableado de distribución de equipos
• Cables de interior/exterior
• Cables de interconexión

Cableado principal ZDA

• Cables de interconexión
• Cables de distribución

© 2019 Panduit Corp. All Rights Reserved 104


TM

Repaso diseño de un enlace de Fibra Óptica

Confidential © 2018 Panduit Corp. All Rights Reserved 105


TM

Elementos de un enlace de Fibra Óptica

© 2019 Panduit Corp. All Rights Reserved 106


TM

Información requerida para especificar


Un enlace de FO
1. ¿Cuánto mide el enlace?
2. ¿Qué velocidad requieren en los enlaces de fibra?
• 1 Giga
• 10 Gigas
• 40 Gigas
3. ¿Dónde de instalarán las fibras?
• Dentro de un gabinete (conectar equipos dentro de un gabinete)
• Únicamente en interiores y la fibra va protegida en una canalización adecuada (p.ej un centro de
datos, un edificio).
• Únicamente en interiores y la fibra NO va protegida en una canalización adecuada (p.ej dentro de
una nave industrial o va colgada).
• Combinación entre ambientes exteriores e interiores (p.ej comunicar dos edificios), la fibra va
dentro de tuberías.
• Combinación entre ambientes exteriores e interiores (p.ej comunicar dos edificios), la fibra no va
por tuberías
• Únicamente en exterior, puede ir colgada o en tubos enterrados
• Únicamente en exterior, puede ir colgada o enterrada sin tubos

© 2019 Panduit Corp. All Rights Reserved 107


TM

Información requerida para


especificar
Un enlace de FO
4. ¿Cuántos hilos requieren por enlace?
• 2, 6, 12, 24, 36 ó 48 hilos. Un puerto dúplex equivale a 2 hilos de fibra.
5. En fibra para interiores ¿qué flamabilidad requieren?
• Riser (la fibra se va instalar en tuberías o canalizaciones cerradas
• Plenum (La fibra se a instalar en espacios abiertos)
6. ¿Qué tipo de conector requieren?
• LC (más común)
• SC (en desuso)
• ST (en desuso)
7. ¿Cómo se hará el terminado de los conectores?
• Prepulido OptiCam (muy rápido y fácil)
• Pulido en Campo (requiere mucha experiencia)
• Pigtail (requiere tener mucha experiencia y tener una fusionadora cara)
8. ¿Qué tipo de fibra requieren?
• Multimodo (distancias cortas)
• Monomodo (distancias largas)
© 2019 Panduit Corp. All Rights Reserved 108
TM

Alcances de la Fibra Óptica

© 2019 Panduit Corp. All Rights Reserved 109


TM

Alcances de la Fibra Óptica


Insertion Loss Budget

2.5 1.5 0.5


S
i OM3 OM4 OM5 SigCore OM3 OM4 OM5 SigCore OM3 OM4 OM5 SigCore
g

10GBASE-SR 270 360 360 480 300 400 400 550 320 440 440 605

40/100GBASE-SR4/10 35 60 60 80 100 150 150 165 150 175 175 230

4G Fibre Channel 295 305 305 320 380 400 400 500 455 495 495 615

8G Fibre Channel 8G 115 125 125 165 150 190 190 250 200 240 240 300

16G Fibre Channel 45 55 55 140 100 125 125 200 140 170 170 225

32G Fibre Channel 45 65 65 80 70 100 100 120 90 125 125 150

Cisco 40G BiDi 60 85 85 165 100 135 135 200 115 160 160 215

100GBASE-SR4 50 70 70 85 70 100 100 125 90 125 125 160

© 2019 Panduit Corp. All Rights Reserved 110


TM

Determinar el tipo de Fibra Óptica

© 2019 Panduit Corp. All Rights Reserved 111


TM

Opticam 2.0

© 2019 Panduit Corp. All Rights Reserved 112


TM

Opticam 2.0

© 2019 Panduit Corp. All Rights Reserved 113


TM

Cable Management
Density Solutions

Opticom

QuickNet
SFQ

HD Flex

© 2019 Panduit Corp. All Rights Reserved 114


TM

Cable Management
Comparison

Opticom SFQ HD Flex


Max Fiber / 1RU (LC
96 96 144
Duplex)
Max Copper / 1RU 24 48 -
Cassette mounting Front Rear Front & Rear
Copper / Fiber in 1RU Yes Yes No
Zero RU available Yes Yes Yes
Patch Panel Yes Yes Yes
Enclosures Yes No Yes
Cassette port options 6, 12 6 4, 6, 12
Shuttered cassettes Non-Std Non-Std Yes
24F MPO (cassette) Non-Std No Yes

© 2019 Panduit Corp. All Rights Reserved 115


TM

Cable Management
Opticom FCE-U Series Enclosures

© 2019 Panduit Corp. All Rights Reserved 116


TM

Cable Management
HD Flex™

Duplex LC Cassettes
• Single mode & multimode

• Available in three widths


‒ 4 duplex LCs
‒ 6 duplex LCs
‒ 12 duplex LCs

• Several configurations
‒ 4-to-1 migration
‒ 12-fiber splice (pigtail)
‒ Standard fanout
‒ Method A
© 2019 Panduit Corp. All Rights Reserved 118
TM

Cable Management
HD Flex™ Cassettes & Modules

LC Cassette
• MPO to 6-port LC breakout
• Singlemode & Multimode

MPO Fiber Adapter Panel


• Cross connect or interconnect in high-density
backbones or parallel optics applications
• Unique peg-board feature to help route MPO cables

LC Splice Cassette and Adapter Panel


• Splicing capability integral to cassette
• Handles either 12F splice or 250µm single fiber splices
• Doubles as LC Adapter Panel

© 2019 Panduit Corp. All Rights Reserved 119


TM

Cable Management
HD Flex™

Removable rail
HD Flex Enclosures & Panels HD Flex 1 RU Panel

• Available in 1, 2, and 4 RU heights

• Can accept either 4, 6, 12-port cassettes


‒ Convertible in the field
‒ Can mix-n-match cassette widths

• Flexibility to accommodate future 0RU Bracket


- stackable

© 2019 Panduit Corp. All Rights Reserved 120


TM

Cable Management
HD Flex™ 12-Port vs 6-Port vs 4-Port

• Only 2 cassettes • 4 trunks and 4 cassettes • 6 trunks and 6 cassettes


• Lower installed cost than 4- • Similar installed cost to 12-port • Higher installed cost than 12-
port • Rapid installation time port
• Rapid installation saves more $ • More cables to manage • Longer installation time
• Minimal cables to manage • Many cables to manage

© 2019 Panduit Corp. All Rights Reserved 121


TM

Fiber Connectivity
PanMPO™ Connector

1
Key - Up
Cambio

2
Polarida 1
1 -Squeeze Outer
d Housing
2 -Pull Forward
Flip & Reinstall Key - Down

Cambio
Género Male
Female
Using Tool, Pull Pins Forward
Remove Outer Housing & Replace Housing

© 2019 Panduit Corp. All Rights Reserved 122


TM

HD Flex Panduit

© 2019 Panduit Corp. All Rights Reserved 123


TM

PAN-MPO

© 2019 Panduit Corp. All Rights Reserved 124


TM

Cable Hibrido de Fibra Óptica y Eléctrico Opti-


Core
• Contiene Fibra óptica
Monomodo y
conductores 12 AWG
para PoE

• Para entregar
información y energía
arriba de 100 m.
‒ WAPs on postes
Riser Indoor-Outdoor ‒ Cámaras de seguridad

Ambientes secos o humedos.

© 2019 Panduit Corp. All Rights Reserved 125


TM

Cajas para Fibra Óptica en exterior

In-Line & Dome


• Bajo tierra
• Entierro directo
• man/hand-hole
• Ambientes húmedos y con
partículas aéreas

Pedestal
• Instalaciones sobre tierra
• Exposición constante al medio ambiente
y partículas

© 2019 Panduit Corp. All Rights Reserved 126


TM

Opciones de fusión para las cajas de FO exterior

Buffered Tube (In-Line & Domes)


Ribbon (In-Line & Domes)

© 2019 Panduit Corp. All Rights Reserved Buffered Tube (Pedestal only) 127
TM

Kit Breakout para FO de alta densidad


• Separa la FO en grupos
manejables para
fusión.

• Mangas expandibles
con suportes de fácil
sujeción “Flex Clips”
para alivio de tensión.

• Bundled fiber is then


routed to enclosures
for splicing

© 2019 Panduit Corp. All Rights Reserved 128


TM

Caja para piso falso HD Flex

§ Flex Zone Raised Floor Enclosure - Gris

§ 288 puertos duplex (576 FO total)

© 2019 Panduit Corp. All Rights Reserved 129


TM

Caja de empalme para montaje en pared


§ Manejo de Cable – Placa trasera removible y
caja de almacenamiento.

§ Paga conforme se vaya creciendo, charolas de


fusión modulares.

§ Seguridad y Flexibilidad – Con chapa, Placas


para cables removibles e intercambiables para
proveer más entradas/salidas.

© 2019 Panduit Corp. All Rights Reserved 130


TM

Pigtails desnudos para fusión MPO

• Perfecto para fusión-masiva y


conectorización de multi-fibras

• Rápido, confiable y sin


problemas de fusión en campo.

• Disponible en MPO y PanMPO


con o sin pines.

© 2019 Panduit Corp. All Rights Reserved 131


TM

Uniboot Patch Cords


§ Monomodo, OM3, OM4, OM4+

§ Un solo cable redondo

§ Fácil cambio de polaridad

§ Incluye pestaña para una fácil extracción en


instalaciones de ultra alta densidad.

§ Plenum y LSZH

§ NOTA: puede ser NO compatible con algunos


transceptores Cisco 25 G

(NOTA: puede ser NO compatible con algunos transceptores Cisco 25 G)


© 2019 Panduit Corp. All Rights Reserved 132
TM

Caja de empalme para exteriores

• Montaje en pared (60.96 cm)24" x 24" (60.96


cm)

• Almacena hasta 360 Fibras

• Clasificación NEMA IP66

• Disponible en Acero suave o Acero inoxidable.

• Incluye 5 brackets preinstalados que soportan


hasta 3 charolas para fusión cada uno.

• Incluye 4 carretes (spools) para manejar hasta 3


metros de holgura de FO.

© 2019 Panduit Corp. All Rights Reserved 133


TM

Charolas Blancas

§ Charolas Opticom High Runner

§ HD Flex Enclosure

§ En stock:

§ HD Flex 1RU, 4RU

§ High runner Opticom solutions

© 2019 Panduit Corp. All Rights Reserved 134


TM

Ladder Rack Enclosures

Distribución sobre charola

• Para FO y Cobre

• Montaje para una charola tipo canasta

© 2019 Panduit Corp. All Rights Reserved 135


TM

Soluciones de Enrutamiento de
Infraestructura Fisica

Confidential © 2018 Panduit Corp. All Rights Reserved 136


TM

Surface Raceway
• Edificios donde no hay espacio
para canalización en las paredes
‒ Concreto, Ladrillos

• Re-acondicionamiento de áreas de
trabajo (Brownfields)

• Conectividad densa/Alimentación
eléctrica requerida

• Administrar y ocultar cables,


tuberías, etc. en cualquier área de
trabajo
© 2019 Panduit Corp. All Rights Reserved 137
TM

Overview of Raceway Offering Part 1

LD LDPH LDS
- Aplicaciones Bajo Voltaje - Para aplicaciones con energía - Para aplicaciones con energía
- Ducto de una pieza - Ducto de dos piezas -Ducto de una pieza

Canaleta de un solo Canal

© 2019 Panduit Corp. All Rights Reserved 138


TM

Overview of Raceway Offering Part 2

LD2P10 T45 T70 TG70


- Canal de una – Dos piezas, - Tamaño grande - Tamaño más
Twin70
sola pieza, Canal tamaño grandre Con
doble con divisor intermedio
Con separador separador - Dos T70 Para
interior adicional Snap adicional Snap separar data y
On On energía

Canaleta Multi-Canal (Power Rated)

© 2019 Panduit Corp. All Rights Reserved 139


TM

© 2019 Panduit Corp. All Rights Reserved 140


TM

Canaleta para Oficinas


• Llegar con Voz/Datos a tu
área de oficina

• Usado para canalizar sobre


muebles

• Disponible en cuatro colores


‒ Office Beige (OB)
‒ Office Gray (OG)
‒ Office Slate (OS)
‒ Medium Tone (MT)

• Línea completa con


accesorios

© 2019 Panduit Corp. All Rights Reserved 141


© 2017 Panduit Corp. ALL RIGHTS RESERVED
142 TM

© 2019 Panduit Corp. All Rights Reserved 142


TM

Enrutamiento de cableado aéreo


• Wyr-Grid®: Sistema de enrutamiento de
cableado aéreo
‒ Se reducen los tiempos de instalación.
‒ Hay control del radio de curvatura.
‒ No es necesario cortar las paredes laterales en
las transiciones.
‒ Se agrega soporte lateral solo si
es necesario.
‒ Cascadas de radio de curvatura.
‒ Los empalmes proporcionan unión entre las
secciones.
‒ El sistema Wyr-Grid se puede apilar con
espaciadores.

© 2019 Panduit Corp. All Rights Reserved 143


TM

Ruta del tendido de cables de fibra


FiberRunner

Sistema de
enrutamiento de
cableado aéreo para
el tendido de fibra

© 2019 Panduit Corp. All Rights Reserved 144


145 TM

FiberRunner Acopladores rápidos snap-in

• No exceder el25% de capacidad inicial y jamás


exceder el 50% de capacidad.
• Fácil conexión con acopladores pre ensamblados.
• Utilización de bajadas laterales o intermedias para una
fácil transición .
• Utilización de brackets para soportar la estructura

© 2019 Panduit Corp. All Rights Reserved 145


TM

Break 5 min

Confidential © 2018 Panduit Corp. All Rights Reserved 146


TM

Arquitecturas de Cableado y Administración


en Racks

Confidential © 2018 Panduit Corp. All Rights Reserved 147


TM

Cableado estructurado convencional

• Múltiples “home-runs”

• Ineficiente

• Costoso

© 2019 Panduit Corp. All Rights Reserved 148


TM

Cableado estructurado por zonas

•Efectivo en costo

• Flexible

• Accesible

• Escalable

© 2019 Panduit Corp. All Rights Reserved 149


TM

Tradicional vs. Cableado por Zonas

Gabinetes
zonales

Cuarto de
Telecom

© 2019 Panduit Corp. All Rights Reserved 150


TM

Zone Topology Benefits


• Provides accessibility and flexibility to reconfigure
offices to meet frequently changing organizational
requirements

• Reduces network downtime when changes are required

• Reduces labor costs when changes occur

• Solves telecommunication room congestion

• Offers power supply diversity

• Not limited by 90 meter copper limitation when using


active enclosures

© 2019 Panduit Corp. All Rights Reserved 151


TM

Redes Distribuidas– Gabinetes de Telecomunicaciones

Wall Mount
Cabinets
PanZone® In-Ceiling Enclosures

PanZone® Active

Enclosures
Wall Mount
© 2019 Panduit Corp. All Rights Reserved 152
TM

Wall-Mount Cabinet Highlights


Up to 26.8” Deep for Active Equipment

Removable side panels Up to 350 lbs. load rating

Reversible hinged front and


rear doors 12RU Cabinet - Pictured

Multiple Accessories Available


© 2019 Panduit Corp. All Rights Reserved 153
TM

PanZone Wall Mount Cabinets


NUEVO
• Multiple Cabinet sizes Available
‒ 12 RU, 18 RU, 26 RU
‒ 25” Depth, 30” Depth
‒ Window or Perforated Doors

• Hinged front and rear doors


‒ Allows easy access to networking equipment

• Removable side panels for easy access to


cabling

• Accepts 19” EIA rack mount panels and


equipment
12 RU 18 RU 26 RU
• Thermally designed and tested for optimized
airflow to improve heat dissipation
‒ Optional fan kits available separately
© 2019 Panduit Corp. All Rights Reserved 154
TM

PanZone Wall Mount Cabinets (cont.)


• Adjustable #12-24 threaded rails
‒ Adjustable in 0.9” increments
‒ Optional rear rails available separately
‒ Rack spaces identified by marks for easy identification

• Accepts active equipment up to 26.8” deep


‒ 21.8” working depth for 25” Cabinets

• Tested to 2X the working load capacity


‒ 12RU – 250lbs.
‒ 18RU – 300 lbs.
‒ 26RU – 350 lbs.

• Wireless access point and conduit knockouts

• Various accessories available separately


© 2019 Panduit Corp. All Rights Reserved 155
TM

PanZone Wall Mount Cabinets (cont.)

© 2019 Panduit Corp. All Rights Reserved 156


TM

TrueEdge: Vertical Wall Mount Enclosure


July 20
20
• Efficient and cost-effective way to deploy switch and
server systems in open architecture environments
• Vertically Mounts up to 36” of active equipment in
compact spaces
• Telecommunication “Room-in-a-Box” (Mini-TR)
• Used in EDGE applications: moving compute closer
to the user

• Used as a Micro Data Center

© 2019 Panduit Corp. All Rights Reserved 157


TM

TrueEdge Wall Mount Enclosure


July 20
‒ Strong - Load Rating: 400lbs UL 2416 pending
20
‒ Thermally Tested
‒ 9RU Enclosure dissipates up to 4,000W of generated heat
‒ Secure - Locking Swing handle door
‒ Optional SmartZone Secure access handle
‒ Saves Space
‒ Low Profile
‒ Replaces a TR, or used as an extension of the TR
‒ Micro Data Center
‒ Scalable
‒ Accepts equipment up to 36” deep
‒ Variety of RU sizes
‒ 3 Active + 3 Passive RU (WME3BL): 42”H x 28.6”W x 9.5”D
‒ 6 Active + 6 Passive RU (WME6BL): 42”H x 28.6”W x 14.8”D
‒ 9 Active + 9 Passive RU (WME9BL): 42”H x 28.6”W x 20”D

© 2019 Panduit Corp. All Rights Reserved 158


TM

Features Estimated UL: 400lbs Static Load Rating

Adjustable
Equipment
Brackets

Easy Equipment Access


and Reversible Door
Cage Nut
© 2019 Panduit Corp. All Rights Reserved
Pictured: 3RU (WME3BL) or 159
TM

TrueEdge 9RU Thermal Testing


July 20
20
• Thermal Capacity 9RU
• 4,000W @ Ambient Room temp 72 degrees
• With 2 fan kits

• Tested to support 6 POE switches


• 2,500W thermal load capability
• Switch equipment fans are not powerful enough to exhaust hot
air fully out of the enclosure, limiting the thermal capacity to
2,500W

• Tested to support 8 1RU servers


• 4,000W thermal load capability

© 2019 Panduit Corp. All Rights Reserved


Shown in Photo: 1PDU, 4 Servers, 1 Switch, 2 Patch Panels160
TM

Consolidation Point Benefits


• Provides a point of configuration in a permanent
link for network interconnection and cross
connections

• Provides accessibility and flexibility to reconfigure


cable runs to meet frequently changing
organizational requirements

• Reduces network downtime when changes are


required

• Reduces labor costs when changes occur

© 2019 Panduit Corp. All Rights Reserved 161


TM

Consolidation Point Box


• Flexibility in Installation
‒ Drop-In panel design reduces installation and
reconfiguration time
‒ In Ceiling and Raised Floor Mountable
‒ Wall mountable
‒ UL2043 Plenum Pending

• Versatility in Configurations
‒ 6 and 12 port boxes include modular panels
‒ 24 and 48 port boxes accept Standard 19” panels
‒ Compatible with NetKey, MiniCom, QuickNet, and
Fiber Cassettes

• Protection of Investment
‒ Covered Cable Connections 48 Port
‒ Foam seal eliminates dust and debris

24 Port
Part Number: CPB*BL 12 Port
© 2019 Panduit Corp. All Rights Reserved
6 Port
162
TM

Consolidation Point Box Features


Openings to Maximize
Cable Capacity

Foam seal prevents


excess dust and debris

Removable latching
cover protects ports

Optimum Bend Radius


Control
© 2019 Panduit Corp. All Rights Reserved 163
TM

Consolidation Point Box Highlights


Supports NetKey and
MiniCom

Drop-In panels provide


best in class installation

6 & 12 port panels accept Supports QuickNet and


MiniCom Snap-In Fiber Cassettes
faceplates

Part Number: CPB*BL


© 2019 Panduit Corp. All Rights Reserved 164
TM

Gabinetes Net-Verse
“Versatilidad simplificada para Redes”

Confidential © 2018 Panduit Corp. All Rights Reserved 165


TM

Versatilidad de Red Simplificada

•Centro de Datos
Múltiples •Redes Empresariales
Aplicaciones •Co-location

•16 Modelos
Simple y •Versiones 42UR y 45UR con 1,000mm o 1,200
Versátil mm de profundidad y 600 mm y 800mm de ancho

•Carga Estática de 3,000 lbs / 1,360 Kg


Confiable •Carga Rodante de 1,100 lbs / 498 Kg

•Compatible con aplicaciones para servidores,


Estructura switches y networking
Universal
•Facilita el montaje de equipo

© 2019 Panduit Corp. All Rights Reserved 166


TM

Características de Productos Net-Verse

Los gabinetes se muestran con


accesorios opcionales instalados y
sin algunos de sus componentes
para facilitar su vista interior.

© 2019 Panduit Corp. All Rights Reserved 167


TM

Descripción: Net-Verse™
• Gabinete Versátil – para Servidor y Redes
• Fondo: 1000 mm y 1200 mm
• Altura: 42 RU y 45 RU
• Ancho: 600 mm y 800 mm
• Puertas: Puerta curveada al frente, y puertas traseras divididas y
perforadas con apertura de 69% para el máximo flujo de aire

• Capacidades de carga:
§ Carga Estática de 3,000 lb / 1,360 kg
§ Carga Rodante de 1,100 lb / 498 kg

• Características clave: Rieles para equipo totalmente ajustables;


puertas con múltiples puntos de bloqueo, ménsulas PDU dobles y
universales, y paneles laterales divididos horizontalmente.

© 2019 Panduit Corp. All Rights Reserved 168


TM

Definición de su Número de Parte

D N 6 2 1 2 B
Color
D - Tipo B – Negro

Páneles
Net-Verse laterales
2 – con
Ancho 9 – sin
6 – 600mm Fondo
8 – 800mm 1 – 1000mm
2 – 1200mm
Altura
2 – 42RU
5 – 45RU

© 2019 Panduit Corp. All Rights Reserved 169


Confinamiento

TM

© 2019 Panduit Corp. All Rights Reserved 170


TM

Why is Energy Efficiency Important?

§ Energy Cost related to cooling


accounts for
-Nearly 37% of the overall
data center power consumption

-Fastest Rising Data Center


operation cost

§ Power and cooling capacity remain


top targets for efficiency improvements

© 2019 Panduit Corp. All Rights Reserved 171


TM

Energy Efficient Data Center Thermal Products - Strategy


• Allow higher data center temperature set points

• Reduce cooling system energy consumption by up to 40%

• Extend life and capacity of IT and cooling equipment


Direct cold air to
Seal every gap Monitor
Separate Hot and Cold Air equipment air
inlets

Controlling Small Leaks and Maintaining Hot/Cold Air Separation Leads


To Large Cooling Energy Savings
40%
A Panduit
Advantage
Refer to Panduit Whitepaper WP-20 – Impact of Air Containment Systems
© 2019 Panduit Corp. All Rights Reserved 172
TM

Panduit Thermal Management Solutions - Product Overview

Universal
Cold Aisle Hot Aisle VED Exhaust/Inlet Sealing
Aisle
Containment Containment Cabinets Ducts Accessories
Containment

© 2019 Panduit Corp. All Rights Reserved 173


174
TM

Cold Aisle and Hot Aisle Containment

Cold Aisle Containment (CAC) Hot Aisle Containment (HAC)

© 2019 Panduit Corp. All Rights Reserved 174


175 TM

Containment Impact

Hot Air Hot Spots in


Recirculation Cold Aisle

Contain
Cold Air

Assess Current Condition

Model End State Condition


© 2019 Panduit Corp. All Rights Reserved 175
TM

Cabinet-supported Cold and Hot Aisle Containment (CAC and HAC)


Containment – Objectives:
• Completely isolate cold air from hot air
Cabinet • To control and stabilize power consumption
Supported
• Reduce cooling energy cost
CAC
• Result – Reduce overall operational costs

Application:
• New Datacenter (Greenfield)
• Panduit Cabinet
• Cabinet support mount
• Fully populated cabinet pod
Cabinet Supported
Cabinet • Cabinet must be the same height
Vertical Exhaust Ducts
Supported • Cabinet Pod is stationary
HAC

© 2019 Panduit Corp. All Rights Reserved 176


TM

Universal Aisle Containment -Advantages


• Can be installed in Existing or New Data Centers

• Independent Floor Supported Structure


• Height Adjustable – 42 to 45 RU or 48 to 52 RU
• Configurable to Cold Aisle or Hot Aisle Containment
• Compatible with Panduit or Competitive Cabinets
• Cabinet heights can be different in a row
• Can Be Installed without any cabinets
• Expandable length over time
• Tool-less blanking panels
• Containment systems save up to 27% on Operational
Expenses

© 2019 Panduit Corp. All Rights Reserved 177


TM

Components of The UAC Containment System

§ End of Row Frame and Wall Beams


§ Roofing Panels
§ Full Height Blanking Panels
§ Clear Doors

Can Be Installed Like This


“Day 1” Without Any Cabinets

© 2019 Panduit Corp. All Rights Reserved 178


TM

Universal Aisle Containment


Most Common – Application on “Day 2”
Retrofit Application

Partial Populated Cold Aisle Containment Partial Populated Hot Aisle Containment

© 2019 Panduit Corp. All Rights Reserved 179


180
TM

Application Flexibility 2

© 2019 Panduit Corp. All Rights Reserved 180


TM

Universal, Single Row Containment


Used in Colocation Cages or “That last row” of the Data Center

Contained Aisle width: Min. 40.5” up to 47.25”(inches) [Distance


between Cabinet frame to Wall]

Wall/ Cage

Roof
Panel

Single
Sliding
Door

Wall Seal Kit


Cabinets
© 2019 Panduit Corp. All Rights Reserved 181
TM

Project Application Pictures:

© 2019 Panduit Corp. All Rights Reserved 182


TM

Project Application Pictures Continued:

© 2019 Panduit Corp. All Rights Reserved 183


TM

Standards for UAC


• NFPA 75 compliant to address Aisle Containment in Data Centers

• Nonmetallic components (Accordance with UL 723 and ASTM E84)


‒ Made with material having a maximum, Flame Spread of 50
‒ Maximum smoke development of 450

© 2019 Panduit Corp. All Rights Reserved 184


TM

Compliance with NFPA 13 – Sprinkler Systems


• NFPA 13 requires that containment
systems

not create obstructions to the fire


suppression

system

• Panduit’s Aisle Containment complies as

it allows installers to route the sprinkling

system

© 2019 Panduit Corp. All Rights Reserved 185


TM

Panduit Net-Contain™ Vertical Exhaust System (VED)

Application of VED Cabinets:


• Vertical Exhaust Duct (VED) Cabinets (aka Chimney cabinets)
are used to provide hot exhaust containment in data centers.
• Solid rear doors capture hot air and direct it through the VED.
• Heated air exhausts upward and away from the cabinet inlet,
preventing recirculation.
• Passive system removes hot air without additional moving parts
• Per VED Cabinets heat load up to 40kW

Benefits:
§ Optimized cooling management for high-density server deployments Cabinet Supported Vertical Exhaust
and heat loads Ducts
§ Maximized return temperatures to the CRAH unit for increased
efficiency and lower energy consumption
§ Increased supply air temperature to achieve operational savings
§ Dampens noise in Data Center
§ Reduces cooling energy costs up to 40%.

© 2019 Panduit Corp. All Rights Reserved 186


TM

In Cabinet Inlet/ Exhaust Ducting Solutions


Direct Cold Air to Where it is Needed:

• Switch Inlet Ducts enable containment strategies


‒ Managing airflow on side to side airflow devices
‒ Channel cold air directly into the switch intake
‒ Creating a front to back airflow pattern

• Switch Inlet Duct enable reduced energy consumption:


‒ Lowering fan speeds on the switch
‒ Allows higher supply air temperature
‒ Allowing higher chilled water temperature

• Panduit has the largest offering of switch inlet ducts:


‒ Cisco Nexus, MDS, and Catalyst A Panduit
‒ Juniper EX Series Advantage

• Exhaust Ducts recommended for when containment is not used


© 2019 Panduit Corp. All Rights Reserved 187
TM

In Cabinet Inlet/ Exhaust Ducting Solutions

§ Various Switch Manufactures sell switches with four different Airflow patterns

-Switch Non-port side to port side (Server Cabinet front to back)

-Switch port side to non-port side (Network cabinet only front to back)

-Switch Side to Side

-Switch Side to Back

© 2019 Panduit Corp. All Rights Reserved 188


TM

Seal Every Gap – Sealing Accessories


Blanking Foam Strips
Raised Floor Sealing Grommets

Blanking Shade
Tool-less Blanking Panels
Cabinet Top Air Sealing Fitting

1RU and 2RU (Black and White) Up To 51 RU


© 2019 Panduit Corp. All Rights Reserved 189
TM

PDUs G5 & SmartZone DCIM

Confidential © 2018 Panduit Corp. All Rights Reserved 190


Panduit
Next Generation Advanced
Intelligent Power Distribution Unit (G5 iPDU)
TM

Retos
§ Mantener disponibilidad y up-time
§ Reducción de costos (Power & Cooling)
§ Mejor la utilización (Power, Cooling &
Space)
§ Administrar grandes movimientos y
operaciones
§ Mantener un alto nivel de seguridad
§ Adopción de soluciones DCIM
§ Mediciones continuas y mejoras: PUE,
DCiE
§ Iniciativa Verde

© 2019 Panduit Corp. All Rights Reserved 192


TM

iPDU G5 video

© 2019 Panduit Corp. All Rights Reserved 193


TM

iPDU
Hot Swappable
Network Module Acceso a redes
Para fácil mantenimiento
redundantes (RNA)
Alta Densidad Y actualización
2N configuración para red o
Configuración de los
tenant/client
puertos de salida Medición Corriente y
permite Código de colores en las
energía (V,A,VA,
configuraciones de
Diseño de bajo perfil W,KWh,pf) precisión de +/- Tomas y por circuito
hasta 42 con salida
Líder en el diseño 1% billing-grade accuracy Para fácil identificación y
del cable arriba o
Ahorra UR y asegura un USB Port administración
por el frente
fácil acceso FW Upgrade /
Configuration

Diseñado para altas temperaturas Premium Hydraulic- Locking IEC Outlets


Seguro, operación segura y confiable Magnetic Circuit Breakers Conexiones seguras
a 60°C con carga completa gracias a locking cords
vendidos por separado

Best-in-Class
Billing Grade Monitoreo ambiental & Seguridad
Accuracy Listo para soportar hasta 8 sensores plug and play
Lectores de proximidad para tarjetas
+/- 1% throughout entire
range of operational
spec
Conexión en serie
Hasta 4 PDU’s
© 2019 Panduit Corp. All Rights Reserved y 32 sensores 194
TM

Múltiples niveles de inteligencia y variantes de configuración


• Familias
• Básicas
• Monitored Input
• Monitored Switched
• Monitored per Outlet
• Monitored & Switched per Outlet

• Orientación, forma y tamaño

• Voltaje y corriente

• Tipo de plug

• Tipo de receptáculo

• Número de receptáculos

• Normas internacionales

© 2019 Panduit Corp. All Rights Reserved 196


TM

Gran oferta de tamaños

© 2019 Panduit Corp. All Rights Reserved 197


TM

Por forma Brakers más altos (75-


Breaker agrupados junto a 95mm) Se agrupan abajo
los contactos cuando es
posible para incrementar la
densidad de puertos

Breaker de bajo
perfíl (52mm)

Dobles puertos para


máxima densidad
Los breakers se
agrupan abajo para
aumentar la
densidad
© 2019 Panduit Corp. All Rights Reserved 198
TM

Bloqueo de puertos y cables


• Outlets con
Locking Espacio diseñado
compatibles con V para los sinchos
y W power cords

• W power cords
provén de bloqueo
en ambos
extremos (PDU y
equipo)

• Variedad de power
cords (colores y
tamaños)

• Cinchos para
sujetar los cables

© 2019 Panduit Corp. All Rights Reserved 199


TM

BYOD
G5 iNC Access
Web GUI
(Intelligent Network Controller) (Multi-Device)
HotSwapable / Upgradable

Desktop

iPDU
Login

ePDU
Tablet

uPDU
(2018)

Dashboard

wPDU Smartphone
(Future)
© 2019 Panduit Corp. All Rights Reserved 200
TM

Pantalla OLED
iPDU ePDU
de alto contraste
Botón de menú
Bajo Costo
Reset Status LED
Verde = OK
No Display
Amarillo = Warning
Amarillo parpadeando = Firmware No Network
update Connection
Puerto USB para Rojo = Error
firmware y
configuraciones 1Gb Ethernet Port No USB
para conexión a la red

Salida para Mantiene


realizar Salida para realizar funciones de
conexión en conexión en serie con iPDU y
serie con PDU’s
sensores
PDU’s
Puerto de Puerto de sensores
sensores

© 2019 Panduit Corp. All Rights Reserved 201


TM

Redundancia para acceso a la red y CoLo/Tenant Dual Access


• Permite dos conexiones separadas a la red a través de Conexión en
Serie
• Facilita el monitoreo y uso de energía
• Manejo de las PDUs a través de la red

• Soporta dos iPDUs, dos iPDUs y un ePDU, o dos iPDU’s y dos ePDUs

Management Facilities
Network Network

© 2019 Panduit Corp. All Rights Reserved 202


TM

Balance de cargas– Vía Código de colores y tiempo en tiempo real

Outlets y breakers con Código de colores para fácil identificación y balance de cargas.

Visualización de carga de cada


fase

Facilita el balance de carga en las 3


fases

Toda la información de las bases


puede ser obtenida a través SNMPv3,
RESTful APIs & CLI.

© 2019 Panduit Corp. All Rights Reserved 203


TM

SmartZone G5 Accessories – Environment, Security & Power Cords


Plug & play style digital sensors (self-identifying electronics design)

Environmental
• Temperature
• Temp + Humidity
• 3Temp + Humidity
• Rope Leak
• Spot Leak
• 3 Sensor Input Hub
• Dry Contact input PDU iNC
Sensor Hub

Security Access Hub


• Door Contact Switch
• Access hub for smart handle
• Auto Light Bar
External Sensor Open/Close
Input Port Sensor
Power Cords
• W & V Locking Cords

© 2019 Panduit Corp. All Rights Reserved 204


TM

SmartZone G5 PDU Accesorios de conectividad


Pasillo caliente PDU Cold Aisle PDU
LÁMPARA AUTOMÁTICA

UUSB

CHAPA ELECTRÓNICA Y SOLO T


CONTROL DE ACCESO CHAPA ELECTRÓNICA Y
CONTROL DE ACCESO 3T+H

OPTION

OPTION

Contacto Contacto Cuerda


seco seco detección
de agua
Contacto Contacto
iPDU iPDU o ePDU Seco
seco
CONEXIÓN EN SERIE

© 2019 Panduit Corp. All Rights Reserved 205


TM

Beneficios de las PDUs


inteligentes Reduce la posiblidad de escases
§ Alarma por falta de energía
Reduce costos de la energía
§ Alarma de posibles puntos calientes
• Identificar equipos ineficientes de alto
consumo § Alarma ante una posible sobrecarga

• Consolidar equipo desaprovechado § Encendido secuencial

• Balance de energía y presión de aire


Capacidad de administración
• Monitoreo de sobre enfriamiento • Encontrar el mayor espacio y
capacidad

• Realizar planeación de expansión


© 2019 Panduit Corp. All Rights Reserved 206
TM

Value Summary!
Extensive Configurations w/ Multiple Hot-Swappable Plug-n-Play Best-in-Class
Best-in-Class Form-factors Intelligent Network Controller (iNC) Accessories Performance & Features

Environmental

High Temp
Quality &
Reliability

wPDU
Hot-Swappable
(Future) High Density & Upgradable
Power
Security
PDU iNC

iPDU
(Intelligent) Access
Hub Hardened 1G
Security Redundant
Networking

ePDU External Sensor Open/Close


Input Port Sensor
(Expansion) Real-Time Environmental
Monitor Plug & Play
Power Cord &
Sensors
Cable Ties
uPDU Scale-out!
(Future) Plug & Play! Multi-Device
WebGUI Multi-Color
© 2019 Panduit Corp. All Rights Reserved 207
PViQTM Solución
Independiente
Presentador

TM

© 2019 Panduit Corp. All Rights Reserved 208


TM

Retos
Desafíos de gestión remota Administrar la vulnerabilidad de
seguridad
• Desconexión maliciosa
• Desconexión accidental

Corp DC Gestión del impacto financiero del


Edge DC Colo-Tenant tiempo de inactividad
• Productividad perdida
• Costo laboral adicional
• Pérdida de negocios

Branch Call Center

Solución SmartZone Connectivity (PViQ™)


Ayuda a las partes interesadas de TI a abordar el riesgo al proporcionar monitoreo y visibilidad
en tiempo real de la conectividad de la capa física para la disponibilidad, confiabilidad y
seguridad de la red.
© 2019 Panduit Corp. All Rights Reserved 209
TM

Desafíos de seguridad de conectividad

• Sitios Edge y Colo-Tenant remotos y aislados


• No hay visibilidad de una posible vulnerabilidad de seguridad
• Sin visibilidad en conectividad de capa física de alta densidad.
• La infraestructura física se pasa por alto en gran medida
• Sin monitoreo y alertas en tiempo real
• Pérdida de negocio y violación de datos.

© 2019 Panduit Corp. All Rights Reserved 210


TM

Solución Independiente PViQ


Establecer una política de seguridad portuaria para • Alerta visual local
interconexión y conexión cruzada • Instrucciones de recuperación
Desconexión del cable o alerta de seguridad de conexión: • Auditoría completada
• Alerta de evento enviada
Alertas de correo
electrónico en tiempo
real (desconectar,
conectar, etc.)
WebGUI para acceso remoto, BYOD y
configuración y actualización Navegador

Gráficas
Alarmas
Historial / Logs
© 2019 Panduit Corp. All Rights Reserved 211
TM

Casos de uso de soluciones: infracciones de seguridad


Sitios de inquilinos de EdgeDC y ColoDC con equipo remoto aislado

Desconexión maliciosa Puenteo SmartZone


Servidor de alarmas
DCIM CONNECT

rap
T Alarm Email
rm
A la

Conexión Desconexión accidental Al


ar
m
Em
ail

© 2019 Panduit Corp. All Rights Reserved 212


TM

Propuesta de valor
• Configuración de políticas de seguridad por puerto, monitoreo y alertas
• Información en tiempo real sobre el estado de conectividad de la red.
• Supervisar y alertar sobre cualquier cambio en el Panel de Parcheo.
• Monitoree los riesgos de seguridad basados en la conectividad.
• Refuerce la seguridad con cifrado avanzado.
• Sistema de gestión basado en WebGUI.
• Interconexión y conexiones cruzadas.
• Aseguramiento de detección de presencia de cable.
• Mapeo de cables y rastreo visual.
• Opciones de cobre y fibra.
• Panel actualizable en campo.
• Escalabilidad Centralizada a través de SmartZone DCIM
© 2019 Panduit Corp. All Rights Reserved 213
TM

PViQ™ Intelligence Module

El firmware SZ Connectivity y un conjunto PViQ Patch Panel


compatible de dispositivos de hardware
inteligente PViQ ™ proporcionan una gestión G5 PDUs
de conectividad activa y pasiva.

Juntos, reducen los errores de


implementación con correcciones de
violación controladas y guiadas, e
información de recursos de red para ayudar
al proceso de planificación de capacidad.

© 2019 Panduit Corp. All Rights Reserved 214


TM

Hardware

© 2019 Panduit Corp. All Rights Reserved 215


TM

Violaciones de seguridad - Notificación de hardware

–Conexión no autorizada:
• Se realizó una conexión de puerto inadecuada debido a una conexión al puerto o conexión
incorrecta sin aprovisionarlo primero.

–Desconexión no autorizada:
• El puerto espera estar en una conexión de doble extremo, pero está desconectado.

© 2019 Panduit Corp. All Rights Reserved 216


TM

LED de estado del puerto y alertas

© 2019 Panduit Corp. All Rights Reserved 217


TM

Estado del panel LED y alertas

© 2019 Panduit Corp. All Rights Reserved 218


TM

WebGUI de múltiples dispositivos y fácil de usar

Navegación

Inicio de Sesión
Segura vía Web (HTTPS)

Visualización de alarma
© 2019 Panduit Corp. All Rights Reserved 219
TM

Multi-Device & User-Friendly WebGUI

Detalles de parches / conectividad

Alarma de ubicación de violación de seguridad

Alarma de conexión de cable no autorizada


© 2019 Panduit Corp. All Rights Reserved 220
TM

Multi-Device & User-Friendly WebGUI


Historial de Configuración de Red
Alarmas

© 2019 Panduit Corp. All Rights Reserved 221


TM

Solución de software de conectividad DCIM SmartZone (opcional)

Características clave
• Gestión de conectividad de red de
extremo a extremo
• Capacidad de cableado
• Notificación automática del estado del
enlace
• Dispositivos de reconciliación automática

Valor:
• Acorta el tiempo de resolución de
problemas de conectividad
• Proporciona capacidad de cableado para
una implementación de activos más
rápida
• Notificaciones de dispositivos en línea /
fuera de línea
• Notificación de dispositivos que necesitan
ser reconciliados

¡Gestión Centralizada!
© 2019 Panduit Corp. All Rights Reserved Connectivity222
Plataformas para
Monitoreo y Gestión
Ambiental en un
Centro de Datos
Presentador

TM

© 2019 Panduit Corp. All Rights Reserved 223


TM

Portafolio de Soluciones y Productos PANDUIT


PDU iNC

Access
Hub

External Sensor Open/Close


Input Port Sensor

SmartZone DCIM

Panduit G5 PDU’s Inteligentes

Synapsense: Monitoreo Temperatura, Humedad y Control de Sistemas de Enfriamiento Sistema de Confinamiento


© 2019 Panduit Corp. All Rights Reserved 224
TM

Necesidades
actuales de los
Centros de Datos

© 2019 Panduit Corp. All Rights Reserved 225


TM

Inversión en Infraestructura comparada con la


longevidad de los sistemas
7% Infraestructura
20+ años (o para siempre!)

60% Software

10% Operación 2 a 5 años


5 años

23% Networking
Networking

23%
5 años
5 años

10% OperaciónSoftware
5 años
60% 2 a 5 años

7% Infraestructura
20+ años (o para siempre!)
*Sage Research

80% de los problemas de la red


son causados por únicamente el 7% del presupuesto invertido.
226
© 2019 Panduit Corp. All Rights Reserved 226
TM

• Monitoreo de Energía

• Monitoreo de Equipos de Red

• Monitoreo de Temperatura

• Control y Administración de Activos.

• Detección de Incendios

• Sistema de Alarmas

• Seguridad

• Solución Centralizada de Monitoreo

• Reportes y Analíticos (Optimización – ROI)


© 2019 Panduit Corp. All Rights Reserved 227
TM

Panduit’s DCIM Solutions

Monitors and analyzes data from Focuses on cooling optimization


Power, Environmental, Asset, and in the Data Center
Connectivity sensors

© 2019 Panduit Corp. All Rights Reserved 228


TM

© 2019 Panduit Corp. All Rights Reserved 229


TM

SmartZone Panduit

© 2019 Panduit Corp. All Rights Reserved 230


TM

© 2019 Panduit Corp. All Rights Reserved 231


TM

© 2019 Panduit Corp. All Rights Reserved 232


TM

© 2019 Panduit Corp. All Rights Reserved 233


TM

Un enfoque completo

© 2019 Panduit Corp. All Rights Reserved 234


TM

Valor SynapSense - Monitoreo ambiental del Centro de Datos


• Conjunto de características
‒ Monitoree el subsuelo, la rejilla y la temperatura del
espacio en blanco, la humedad y la presión
‒ Proporcionar datos sobre la condición ambiental del
espacio en blanco
‒ Visual Graphical LiveImaging ™ del centro de datos
‒ Análisis, paneles e informes
‒ Métricas predefinidas en torno a los estándares ASHRAE
‒ Alertas: predefinidas y definibles por el usuario

• Valor
‒ Reduzca el riesgo y el costo del tiempo de inactividad:
descubra los problemas de desarrollo
‒ No puede administrar lo que no mide
‒ Reacción más rápida ante posibles problemas.
‒ La gestión proactiva de los resultados del flujo de aire en:
‒ Tiempo de inactividad reducido
‒ Mayor eficiencia
‒ Analice tendencias para posibles problemas y revise
datos que conducen a incidentes
‒ Mejore la eficiencia y la vida útil del equipo optimizando
las operaciones.

© 2019 Panduit Corp. All Rights Reserved 235


TM

SynapSense Value - Active Control


• Conjunto de características
‒ Control optimizado del sistema de enfriamiento
‒ Se integra directamente con el equipo CRAH o CRAC o a través de Building Mgmt. Sistema
‒ Sistemas de agua enfriada (CHW)
‒ Se integra con el control de temperatura y ventilador / VFD para distribuir la carga en
muchas unidades
‒ Sistemas de expansión directa (DX)
‒ Se integra con el control del punto de ajuste y los modos de espera para maximizar la carga
en cada unidad y poner a otros en espera
‒ Mayor control a través de la automatización del sistema.
‒ Haga coincidir el suministro de refrigeración con la carga de TI siempre cambiante
‒ Asegúrese de que las unidades contiguas estén trabajando juntas y equilibradas
‒ Determine automáticamente qué unidades están enfriando qué gabinetes y use los datos
apropiados para controlar las unidades
‒ Alertar al personal del centro de datos si hay condiciones que son incontrolables
‒ Valor
‒ Mayor resistencia y menor riesgo: el sistema de control está sesgado para reducir el riesgo
‒ Reduzca el consumo de energía combinando automáticamente la refrigeración con la carga
de calor.
‒ Los clientes de Panduit han visto hasta un 50% de ahorro en enfriamiento OpEx
‒ Proporcione múltiples niveles de tolerancia a fallas desde fallas redundantes a
notificaciones de personal de DC

© 2019 Panduit Corp. All Rights Reserved 236


TM

DEMO – Synapsense Data Center

© 2019 Panduit Corp. All Rights Reserved 237


TM

APLICACIÓN MÓVIL PARA INSTALADORES


CAPACITACIÓN PARA INSTALADORES CERTIFICADOS

238
© 2019 Panduit Corp. All Rights Reserved 238
TM

Escanear o buscar
Escanee el código de
• Escanee el código de barras de barras
Panduit Part Bag para recuperar la
información de producción y la hoja de
instalación.
‒ Toque cualquiera de los tres escáneres.
Busque por número
‒ Alinee el escáner con el código de de pieza
barras.
‒ Busque por número de pieza.
‒ Haga clic en "Buscar" en la parte inferior
de la pantalla.

© 2019 Panduit Corp. All Rights Reserved 239


TM

Buscar y usar hojas de especificaciones e


instalación
Seleccione la pieza Ver, descargar o enviar la hoja
de la lista de la hoja por correo electrónico.
correspondiente.

Ver
Seleccionar
Descargar PDF
Enviar PDF
por correo
electrónico

© 2019 Panduit Corp. All Rights Reserved 240


TM

Abrir una hoja descargada previamente

• Abra el visualizador de PDF para recuperar hojas de


instalación/especificaciones previamente descargadas

• Los dispositivos de Apple usan iBooks.

© 2019 Panduit Corp. All Rights Reserved 241


TM

Pruebe la aplicación

Escanee estos y
busque las hojas
de instalación y
especificaciones
en su
dispositivo.

© 2019 Panduit Corp. All Rights Reserved 242


TM

QuickReference

• QuickReference

© 2019 Panduit Corp. All Rights Reserved 243


TM

Break 5 min

Confidential © 2018 Panduit Corp. All Rights Reserved 244

You might also like