Sullair filters protect your plant equipment and Particulate Filters: SCF, SCR, PF and PR
processes, improve your product quality and reduce
your energy costs. Sullair offers filters for general High-efficiency pre-filters (after-filters) remove particles
purpose compressed air and for high quality to 1 micron, including coalesced liquid water and
compressed air for instrumentation, food processing lubricants. Maximum remaining aerosol content after
and pharmaceutical production. Sullair filters are filtration is 0.5 ppm @ 70°F.
available from 13 to 16,500 scfm, 15 to 725 psig,
35°F to 250°F, ISO 8573.1 quality classes. High Efficiency Filtration: SCH, SCHR and PH
• Compressed air is filtered to remove atmospheric For maximum filtration, Sullair offers compressed air
particulate, aerosols and other pollutants to provide filters to remove particulate down to 0.01 micron,
compressed air for general purposes to the most including water and oil aerosols, providing a maximum
critical application. remaining oil aerosol content of 0.01 ppm @ 70°F,
• Filtration equipment includes pre-filters, high when used with SCF and PF pre-filters.
efficiency filters and odor-removal filters.
• The type, number, and placement of filters depend Odor Removal: SCC, PC
on the applications and the degree of contaminant
removal required. Sullair filters use activated carbon to remove lubricant
and hydrocarbon odors. After filtration, remaining vapor
Five-Year Filter Guarantee content is less than 0.003 ppm (excluding methane).
This filter installation should always be preceded by
Sullair backs this new technology with a five-year high efficiency filter grades.
warranty on the housing and a five-year warranty on
performance, provided the element is changed annually. Combination Filters: MPHC
This package combines high efficiency and odor-removal
type filters in one housing.
2
New Sullair Filtration Technology
Sullair compressed air filters use very Ordinary compressed air filters have
little energy as they have a low always consumed too much energy,
resistance to air flow. Advancements as they are by design, a restriction to
such as deep bed pleating, graded air flow. During their working life, this
density media and an oleophopic restriction increases dramatically, and
coating have led to a high performance over time, can consume more energy
filter element with low initial energy than they are worth. As service life is
costs. Differential pressure starts low dependent upon differential pressure,
and stays low throughout its life. most manufacturers recommend a
Service life is no longer dependent on replacement filter element between
differential pressure, but is based on 7 psi (500 mbar) and 10 psi (700 mbar)
annual filter element change, backed differential. This adds up to a massive
up with a one-year air quality 3.5% extra in compressor energy costs.
guarantee.
700 10
500
350 5
300 4.5
200 3
100 Starts Low and Stays Low
1
0 0
Months 1 6 12
700 10
500
350 5
300 Wasted Energy 4.5
200 3
100 1
0 0
Months 1 6 12
Air Stabilizers
Smooth outlet air flow.
Drainage Ribs
Filter housing and element
integrate to provide capillary
action which greatly improves
liquid drainage. Interaction
between housing and element
also ensures maximum
coalescing performance
is achieved at all times.
5
Sullair Advanced Filter Housings
Filter Connections
More port sizes are available
to match both pipe size and
system flow rate giving additional
customer choice.
Incident Monitor
Used to indicate premature high
differential pressure.
6
Air Quality Standards ISO 8573.1 Classes
Solid Particle
Maximum number of Pressure Oil
Particle size (in microns) of some common substances Class particles per m3 Dewpoint (incl. vapor)
Fumes °F mg/m3
0.1-0.5 0.5-1 1.0-5
Tobacco Smoke micron micron micron
Smog
1 100 1 0 -94 0.01
Oil Aerosols
2 100,000 1,000 10 -40 0.1
Bacteria
3 - 10,000 500 -4 1.0
Ash
4 - - 1,000 37 5.0
Dust
5 - - 20,000 45 -
Fog
6 - - - 50 -
Pollen
0.01 0.1 1.0 10.0 100.0
Sullair
Sullair air compressor refrigerated dryer Low Dew Point
Air quality to ISO 8573.1
Class 2 (dirt), 4 (water), 1 (oil)
Sullair regenerative
dryer Extremely Low Dew Point
Sullair air compressor Air quality to ISO 8573.1
Class 2 (dirt), 2 (water), 1 (oil)
Pressure dew point -40°F (40°C)
instruments
process
air
SCF SCH
SCF MPHC
7
SCF
Specifications:
Sullair SCF, SCH, SCR, SCC and SCHR
Filters
Model Capacity Inlet/Outlet Dimension (in.) Weight
SCF, SCH, SCR
SCC, SCHR @ 100 psig Connection A B C D E (lbs)
20 21 3/8" 3.0 7.2 6.0 - 4.0 0.9
40 42 1/2" 3.8 9.3 7.9 - 4.0 2.2
65 64 3/4" 3.8 9.3 7.9 - 4.0 2.2
125 127 1" 5.1 10.8 9.2 - 4.0 4.9
235 233 1-1/2" 5.1 14.3 12.7 - 4.0 5.7
340 339 1-1/2" 6.7 17.0 15.1 - 4.0 10.0
465 466 2" 6.7 20.6 18.7 - 4.0 11.6
700 699 2" 6.7 20.6 18.7 - 4.0 11.6
910 911 3" 8.1 25.3 22.9 - 4.0 22.0
1315 1314 3" 8.1 32.8 30.4 - 4.0 26.4
2120 2119 4" 16.5 46.2 43.1 - 4.0 98.0
MPHC 13 13 1/4" 3.0 5.3 5.3 5.3 2.8 2.2
MPHC 27 27 3/8" 3.5 6.3 6.3 6.3 3.8 2.7
MPHC 53 53 1/2" 3.5 6.3 7.6 6.3 5.1 3.1
MPHC 84 84 3/4" 4.8 9.8 9.8 9.8 6.8 7.1
MPHC 140 140 1" 4.8 9.8 13.8 9.8 10.8 8.2
MPHC 180 180 1-1/4" 4.8 13.8 13.8 13.8 10.8 8.4
Note: The SCC grade filter will not remove CO/CO2 or other toxic gases or fumes.
Consult factory for additional inlet/outlet connection sizes.
• •
•
• •
D
•
C
B C B
•
• • • •
B
C C
Clearance to E Clearance to E
change element change element
• • •
Clearance to E
Clearance to E change element
change element
8
Specifications:
Sullair PF, PR, PC and PH Welded Housing
Filters
Model Capacity Air In/Out Dimensions (in.) Drain Weight (lb.)
@100 psig A B C D Port (in.)
PF/PR-600 600 2" FLG 17-3/4 35 8-3/4 21 1/2 165
PF/PR-1200 1200 3" FLG 17-3/4 37-1/2 9-1/2 21 1/2 171
PF/PR-1600 1600 3" FLG 20 39-3/4 10-5/8 21 1/2 195
PF/PR-2100 2100 4" FLG 20 39-3/4 10-5/8 21 1/2 267
PF/PR-2750 2750 4" FLG 20 39-3/4 10-5/8 21 1/2 270
PF/PR-4200 4200 6" FLG 24 45 13-1/4 21 1/2 424
PF/PR-7000 7000 8" FLG 29-1/2 54 12-3/4 21 1 720
PF/PR-11000 11000 10" FLG 29-1/8 60-1/2 16 26 1 1040
PF/PR-16500 16500 12" FLG 39-3/8 66-5/8 18-1/2 28 1 1610
PC/PH-600 600 2" FLG 12 37-1/4 6 22 1/2 90
PC/PH-1200 1200 3" FLG 15-3/8 43-3/4 8-1/4 26 1/2 158
PC/PH-1600 1600 3" FLG 20 49-1/2 10-1/4 21 1/2 289
PC/PH-2100 2100 4" FLG 20 49-1/2 10-1/4 21 1/2 304
PC/PH-2750 2750 4" FLG 20 49-1/2 10-1/4 21 1/2 320
PC/PH-4200 4200 6" FLG 22-3/4 50-1/2 12-3/4 21 1/2 451
PC/PH-7000 7000 8" FLG 29-1/2 54 12-3/4 21 1 720
PC/PH-11000 11000 10" FLG 29-1/8 60-1/2 16 26 1 1040
PC/PH-16500 16500 12" FLG 39-3/8 66-5/8 18-1/2 28 1 1610
Dimension “D”: Distance required for element removal
Note: The PC grade filter will not remove CO/CO2 or other toxic gases or fumes.
PF/PR PH PC
Maximum operating pressure 200 psig (14 barg) 200 psig (14 barg) 200 psig (14 barg)
Maximum operating temperature 250°F 150°F 86°F
Minimum operating temperature 35°F 35°F 35°F
Operating pressure differential fully saturated 2.0 psig 3.0 psig 4.5 psig
PC/PH* PF/PR*
• A • • A •
• •
C C
• •
B
B
•
*Consult factory for filter drawings above 4200 cfm
• •
D
•
D 9
Sullair Air Quality Guarantee
Two Levels of Air Quality Maximum remaining oil aerosol content is 0.01 parts per
million by weight (ppm/w) @ 70°F, including oil vapor. The
Sullair recognizes that the air from this Sullair System meets the most stringent ISO
requirements for air quality vary standard (ISO 8573.1, Class 1) for air quality.
according to each compressed air
application. For this reason, Sullair The Sullair Critical Air Quality Guarantee.
provides compressed air Systems that The compressed air from this Sullair System
achieve two distinct levels of air quality exceeds the ISO standard (ISO 8573.1, Class 1) for
and a guarantee for each. air quality with the use of the SCC or PC filter. The
System includes a Sullair compressor, Sullair dryer,
The Sullair System. and Sullair SCF, SCH, and SCC; or PF, PH, and PC
The Sullair System matches a Sullair compressor, filters. The odor-free compressed air from this system
a Sullair dryer and Sullair filters. Sullair assures that contains particulates no larger than 0.01 micron, including
its System will meet specific performance levels water and oil aerosol content of 0.01 parts per million by
throughout its operational life. We offer a one-year weight (ppm/w) @ 70°F. The remaining oil vapor content is
test/review period, backed by a purchase refund less than 0.003 ppm/w.
guarantee, to verify the performance of the Sullair System.
These Systems are not intended to remove carbon monoxide, methyl
isocyanate or other noxious, corrosive or toxic gases, vapors or fumes.
Select the System. The system does not provide breathing air.
Select the air quality level to meet your plant air or process
requirements. You can be assured that the quality of air
from the Sullair System you specify will remain consistent
for the life of the equipment. Sullair guarantees it... and
that’s as good as gold.
by SULLAIR
The Sullair Oil-Free Air Quality Guarantee.
The System consists of a Sullair compressor, Sullair dryer,
and Sullair SCF and SCH or PF/PH filters. The compressed
air from this system contains particulates no larger than .01
micron, including coalesced liquid water and lubricants.
Sullair Corporation
3700 East Michigan Boulevard, Michigan City, IN 46360
Telephone: 1-800-SULLAIR or 1-219-879-5451
www.sullair.com
The paper used in printing this literature was manufactured using recycled fiber, either
pre-consumer or post-consumer waste, therefore less harmful to the environment
because less virgin fiber is used, thereby reducing tree harvesting, water usage, energy
consumption, emission of greenhouse gases and pollution.