0% found this document useful (0 votes)
783 views3 pages

Technical Data Sheet (Triad Cable For Gas Detector)

The document provides a technical data sheet for a triad cable for gas detectors. It includes 3 or less sentences: The document specifies the technical requirements for a 1.5 sqmm, 1 triad stranded copper conductor cable with HR PVC insulation, aluminum-mylar overall shielding, galvanized steel armor, and FRLS HR PVC outer sheathing. The cable meets various Indian and international standards for signal cables and has electrical parameters including a maximum DC resistance of 12.3 ohms/km and insulation resistance of at least 10 megohms/km.

Uploaded by

Vinod Rajput
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
Download as xlsx, pdf, or txt
0% found this document useful (0 votes)
783 views3 pages

Technical Data Sheet (Triad Cable For Gas Detector)

The document provides a technical data sheet for a triad cable for gas detectors. It includes 3 or less sentences: The document specifies the technical requirements for a 1.5 sqmm, 1 triad stranded copper conductor cable with HR PVC insulation, aluminum-mylar overall shielding, galvanized steel armor, and FRLS HR PVC outer sheathing. The cable meets various Indian and international standards for signal cables and has electrical parameters including a maximum DC resistance of 12.3 ohms/km and insulation resistance of at least 10 megohms/km.

Uploaded by

Vinod Rajput
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1/ 3

SHRIRAM TELELINK

POLT NO -46/4/1,SITE -IV INDUSTRIAL AREA SHAHIBABAD GHAZIABAD UP.


TECHNICAL DATA SHEET (TRIAD CABLE FOR GAS DETECTOR)
PO.NO:- GEMC-511687767169566 DATED -05 /08/2021
S.N DESCRIPTION UNIT 1 Triad x 1.5 sq.mm
O. Stranded Annealed Tinned Copper conductor , HR PVC insulated, Overall screened,
1 CABLE TYPE PVC inner Sheathed, armoured and overall FRLS PVC sheathed signal cables.
Gen. conf. to BSEN : 50288-7, IS: 8130/84, IS: 5831/84, IS: 3975, ASTMD: 2863,
ASTMD: 2843, IEC: 754-1, IS: 1554-1, IEC : 60332-
1 and any other applicable standard as mentioned in this
technical specification.
2 APPLICABLE STANDARDS
3 NO OF PAIR / TRIAD Nos. 1T
4 VOLTAGE GRADE V 600
5 CONDUCTOR
Stranded Annealed Tinned Copper conductor conf. to
a) Material class-2 of IS: 8130/84
b) Grade Electrolytic
c) Size Sq.mm 1.5
d) No. of strands No. 7
e) Shape of Conductor Stranded & Circular
6 INSULATION
a) Material HR PVC Insulation (Type-C), Conf,to IS:5831
b) Type Extruded
c) Triad identification Black, Blue & Brown
d) Thickness (min) mm 0.5
cores in a No.
e) pair / triad 10 Twists/metre
7 OVERALL SHIELDING
a) Material Aluminium-Mylar Tape
b) Type Helical
c) Overlap (min.) % 25
d) Coverage (min.) % 100
8 Drain Wire
a) Material Stranded Annealed Tinned Copper
b) No. of strands No. 7
9 INNER SHEATH
a) Materials HR PVC compound (Type ST 2), conf. to IS: 5831/84
b) Type Extruded
c) Colour Black
d) Rip cord Non metallic Rip cord shall be provided below inner sheath
e) Thickness (min) mm 0.30 mm
10 ARMOUR
a) Material Galvanised Steel Round Wire , conf. to IS: 3975
b) Size mm 0.90 mm +/-0.030 mm

11 OUTER SHEATH
HR PVC compound (Type-ST2), conf. to IS: 5831/84 with FRLS
a) Material properties
b) Type Extruded
c) Thickness(Min) mm 1.24 mm
Overall Diameter (approx) mm 12.5 mm
d) Colour of outer sheath Black
Marking on outer sheath SRTL SIZE & TYPE 600 V, shelded, Armoured, FRLS Instrumentation Cable MFY-
e) 2021 with Meter Marking
Drum Length (Packing shall be done 3 drums of 1000 mtrs with +/-5% tolerance and1 drum of 700 mtrs with +/-5%
in nonreturnable wooden drum) mtrs toleranceNOTE: The payment shall be made for the supplied restricted to PO
12a) quantity of 3700 mtrs.
Tolerance on individual drum length
b) %& overall quantity (+/-5 %)
13 ELECTRICAL PARAMETERS
Max. DC resistance of
a) conductor of Ω/Km completed cable at 20 12.3
Deg. C
Max. mutual capacitance of pairs or pF/mtr 250
b) adjacent core at 1KHz
Max. mutual capacitance between any pF/mtr 400
c) core or screen at 1 KHz.
d) Max. L/R ratio μH/Ω 40
Min. insulation resistance at 200 C of
e) completed cables MΩ/Km 10
Max. drain wire resistance
f) including Ω/Km shield at 20 DegC 30
g) High voltage test 1 kV (rms) for 1 minute(core to core)AND 0.5 KV for 1 minute(core to armour)
14 FRLS Properties (On outer sheath)
a) Oxygen Index Min. as per ASTM 2863 % 29 ( at 27°c)
Max. HCL emission as
c) per IEC: 754-I % 20 By weigth
Max. smoke density
d) ratingASTMD: 2843 % 60
e) Flamability test as per IEC-332- max. 60 second/min 50 mm(ineffactive portion)
1 Each cable drum shall be marked with : manufacturer’s name,
15 DRUM IDENTIFICATION details of cable, batch no. / lot no. , length of cable & gross weight.
SRTL/DS/QC/313 Dated :25.06.2021 REV:00
Designed By
Approved By VINOD KUMAR (Q.A. Head)