Kathrein 86010046 PCA

The Portable Control Adapter (PCA) allows remote control of Tower Mounted Amplifiers (TMAs) via an 8-pin connector. It provides 24V DC and 14V DC power to the remote control units (RCUs)/TMAs and can support up to 27 RCUs/3 TMAs within 200m. The PCA connects to a PC via USB to control the RCUs/TMAs using an HDLC protocol and has overcurrent protection, current monitoring, and an operating temperature range of 0-55°C.

Uploaded by

gab man
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
0% found this document useful (0 votes)
303 views1 page

Kathrein 86010046 PCA

The Portable Control Adapter (PCA) allows remote control of Tower Mounted Amplifiers (TMAs) via an 8-pin connector. It provides 24V DC and 14V DC power to the remote control units (RCUs)/TMAs and can support up to 27 RCUs/3 TMAs within 200m. The PCA connects to a PC via USB to control the RCUs/TMAs using an HDLC protocol and has overcurrent protection, current monitoring, and an operating temperature range of 0-55°C.

Uploaded by

gab man
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 1

Portable Control Adapter (PCA)

For Remote Control Unit (RCU)


For Tower Mounted Amplifier (TMA)

Portable Control Adapter


Type No. 86010046
Connector * to RCU/TMA 1 x 8-pin connector according to IEC 60130-9, female,
conforming to AISG RF-connector (SMB male)
Input voltage of PCA 24 V DC
Output voltage to RCU’s/ AISG female pin 6 (24 V DC): 24 V DC ±10%
TMA’s AISG female pin 1 (12 V DC): 14 V DC ±7%
RF male (at 24 V DC): 24 V DC ±10% ***
RF male (at 12 V DC): 14 V DC ±7% ***
Output power AISG female pin 6 (24 V DC)
(power supply to RCU’s/ without load on pin 1 (12 V DC) and on RF-plug: ≤ 60 W
TMA’s) AISG female Pin 1 (12 V DC)
with max. 30 W load on pin 6 (24 V DC) and/or on RF plug: ≤ 30 W
Current monitoring Per branch (12 V, 24 V, RF): 10 – 2500 mA
measurement level
Over-current protection Per branch (12 V, 24 V, RF): < 2500 mA
Interface to RCU/TMA RS 485 / power supply / RF connector (SMB male)
Protocol to RCU/TMA HDLC hex-coded command set, conforming to AISG 1.1 and 3GPP / AISG 2.0
Interface to PC USB 1.1/2.0
Max. number of RCU’s/TMA’s 27/3 pcs., depending on system configuration and length of control cable
Max. length of control cable 200 m / 9 RCU’s (in daisy chain configuration)
150 m / 6 RCU’s (in splitter configuration)
Weight 535 g (incl. external power adapter)
Temperature range 0 ... +55 °C ambient temperature
Height x width x depth 40 mm x 95 mm x 160 mm
External power supply ** Input: 90 – 264 V AC, 47 – 63 Hz
24 V DC / 3.0 A
* Tightening torque for fixing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’).
The connector should be tightened by hand only!
** If powered via AISG-interface, no external power supply is required.
*** Switchable with software

Certificate: CE
FCC part 15 class B
UL (for external power adapter)
Standards: EN 60950-1
EN 55022
EN 55024
System requirements Windows 2000; Windows XP, Vista, Win7
for PCA Software: (32 bit version)
Scope of supply: PCA
External power supply (24 V DC / 70 W)
USB cable
AC power cable
CD-ROM with PCA software, drivers and manual
Installation guide
Subject to alteration.
936.2733/f

All specifications are subject to change without notice.


The latest specifications are available at www.kathreinusa.com
86010046 Page 1 of 1

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com

You might also like