(Kindly Provide Maximum Information Possible) : Annexure-Ii Questionnaire For Sellers of Solar Power Projects in India
The document is a questionnaire for sellers of solar power projects in India. It requests information in 12 categories: 1) Developer details, 2) Site details, 3) Terrain and land details, 4) Solar resource assessment details, 5) Installed capacity details, 6) Energy yield assessment details, 7) Power evacuation arrangement details, 8) Surrounding solar power project details, 9) Status of major approvals, 10) Proposed arrangement for sale of the project, 11) Approximate timeline, and 12) Expected price for sale of the project. The questionnaire seeks technical, location, and approval/permit related information to evaluate solar power projects for potential purchase.
(Kindly Provide Maximum Information Possible) : Annexure-Ii Questionnaire For Sellers of Solar Power Projects in India
The document is a questionnaire for sellers of solar power projects in India. It requests information in 12 categories: 1) Developer details, 2) Site details, 3) Terrain and land details, 4) Solar resource assessment details, 5) Installed capacity details, 6) Energy yield assessment details, 7) Power evacuation arrangement details, 8) Surrounding solar power project details, 9) Status of major approvals, 10) Proposed arrangement for sale of the project, 11) Approximate timeline, and 12) Expected price for sale of the project. The questionnaire seeks technical, location, and approval/permit related information to evaluate solar power projects for potential purchase.
OF SOLAR POWER PROJECTS IN INDIA (Kindly provide maximum information possible)
Sl.No. Information Remarks
1 DETAILS OF THE DEVELOPER i Name of the Developer ii Type of Firm (Proprietary/Partnership/Private Ltd/Other) iii Project installation category - Turnkey, Developer or Resale iv Date of Commissioning (DOC)/Expected DOC v Address vi Telephone vii Fax viii Email ix Website x Name & Designation of Contact Person xi Mobile Number of the Contact Person 2 DETAILS OF THE SITE i Name of the Nearest Village ii Distance & Direction from the Village iii Latitude & Longitude of the site iv Tehsil/Taluka v District vi State vii Country 3 DETAILS OF TERRAIN & LAND i Type of Terrain (Plain/Undulated) ii Elevation range iii Vegetation/Plantation iv Type of Land (Government Revenue/Forest/ Private) Area of land acquired ,whether site is a continuous area or v is spread across multiple locations Approximate Land acquired per MW installation of SPV vi project (in Ha.) vii Status of land Acquisition viii SPP Location wise Survey No., Village, Area ix Land Allotment Order in case of Govt. Land x Land Sale Deeds in favour of the Owner of the SPP xi Details of Land Arrangement for Road, OH line, Office building, Pooling substation Sl.No. Information Remarks xii Non-Agricultural Permission xiii Site Layout map showing SPV array layout, roads, OH lines, Office building, Pooling sub-station duly indicating Khasra/plot boundaries and respective land survey numbers xiv In case of ‘Resale’ project kindly provide the historical generation data 4 DETAILS OF SOLAR RESOURCE ASSESSMENT i Whether solar tracker installed If yes, numbers of pyranometers/pyranometers with shading ii disc/pyrheliometers installed iii Date of installation of solar sensors iv Details of solar resource/data v Period of Availability of solar/Insolation Data vi Location of solar tracker from centre of the site vii Coordinates of the solar tracker viii Availability of Calibration Reports ix Availability of Verification Report, name of verifying agency Name of the nearest solar tracker (installed by other party) duly x indicating distance and direction from the centre of the site xi Coordinates of solar tracker installed by the other party Availability of solar data from external solar tracker duly xii indicating period 5 DETAILS OF INSTALLED CAPACITY i Whether capacity layout of SPV panels planned ii What rating of SPV panel has been considered in carrying out assessment of total capacity iii What is the Total Estimated installed capacity duly indicating Nos., Type, Make, Model, efficiency, etc., of the SPV panels considered; please provide details of tracking mechanism used, if any iv Please provide the details of the inverter used, i.e., type, make, model, rating, etc. v Please provide a list of UTM coordinates of the SPV panel layout vi What is the minimum spacing between two SPV Structures in a row and between two consecutive rows 6 DETAILS OF ENERGY YIELD ASSESSMENT i Whether EYA has been carried out duly indicating name of the agency ii Annual Average Generation & Capacity Utilization Factor iii Please indicate what correction factors have been considered for plant availability, grid availability and transmission loss Sl.No. Information Remarks 7 DETAILS OF POWER EVACUATION ARRANGEMENT i Preliminary Details -Whether proposed to construct a new Pooling substation or planned to connect to the existing Pooling substation or existing grid substation - Details of Proposed Power Evacuation arrangement duly indicating Electrical single line diagram of SPV power project from solar panels upto the metering point of EB for the proposed project. ii Details of the Pooling substation -Name of the Location -Distance & Direction from the centre point of the solar power project -UTM coordinates of the substation -Voltage Ratio -Total Transformer Capacity duly indicating Nos of Transformers & MVA Capacity -Nos. of EHV Feeders duly indicating Voltage -Nos of SPP feeders duly indicating Voltage & Planned Connected SPP capacity -What is the planned total capacity of SPP in MW to be connected to this Pooling substation -Whether the pooling substation is exclusively for use of the proposed SPP or is used by others also on sharing basis -Whether Power Evacuation Permission has been obtained -Physical status of the Pooling substation iii Details of the Nearest Grid substation -Name of the Location -Distance & Direction from the centre point of the solar power project -UTM coordinates of the substation -Voltage Ratio -Total Transformer Capacity duly indicating Nos of Transformers & MVA Capacity -Nos. of EHV Feeders duly indicating Voltage -Nos of SPP feeders duly indicating Voltage & Planned Connected SPP capacity -What is the total connected load at this substation duly indicating type of load -Whether the substation has any windfarm/SPP connected or there is plan of connecting similar or other types of power projects in future. Please indicate the capacity Sl.No. Information Remarks -Whether the substation has spare capacity or there is a space available for expansion -Physical status of the grid substation 8 DETAILS OF SURROUNDING SPV POWER PROJECTS i Name of the Developer ii Make, Model, Rating & Nos of SPV panels iii Distance & Direction from the centre point of the proposed solar power project iv Whether UTM coordinates of the surrounding SPP are available. Approximate range of coordinates. v Actual annual generation of surrounding SPP with details of solar resource, SPV module Availability, Grid Availability , etc. 9 STATUS OF MAJOR APPROVALS i Project approval from State Nodal Agency (SNA) ii Power Evacuation Approval iii Status of Power Purchase Agreement (PPA) iv Status of decision on applicable tariff for sale to EB Note : please provide copies of approvals/clearances 10 PROPOSED ARRANGEMENT OF SALE OF PROJECT i Whether Project approval is in the name of any Special Purpose Vehicle or in the name of the Developer ii What will be the arrangement of Transfer of Project in the name of the Purchaser iii Whether Developer intends to sale project on “As is Where is “ condition or intends to carry out other works also for development of SPP iv What are the services Developer intends to provide to the Purchaser 11 APPROXIMATE TIME LINE i Time required to complete various activities to clear the site for starting the construction activities (Please provide an activity plan in the form of a bar/Gantt chart) ii Time required to commission the project after site clearance for taking up construction activities 12 EXPECTED PRICE FOR SALE OF PROJECT