Basic Operation “Start/Pause” button.
1- Power On The Device To resume your session, press the “Start/Pause” button
Press the ON/OFF button and hold for approximately again.
3 seconds until screen turns on.
Nighttime Use
2- Select Session Time: The screen’s backlight may be turned on momentarily
Press “T” to toggle the session timer between 20 or during a session. To do so, simply press ANY button
30 minutes. one time. The screen will light up for several seconds.
This will not affect your session time, output etc.
3- Select Output Level
Press “U” to increase output from 0.5mA up to Precautions (Also read the “NOTICE” above)
2.0mA. The default output is set to the lowest setting,
0.5mA. This is where we recommend beginning each Healthy adults can use this device.
session. In addition to the notice above, DO NOT use this device
Press D= Adjust the power down. until you have consulted with your doctor or health care
*Tip: You can also continue pressing the “U” or “D” practitioner, particularly if you have any of the
button to scroll through all the outputs; 0.5mA, 1.0mA, conditions below:
1.5mA, 2.0mA. -Bleeding tendency;
-Acute thrombosis.-
4- Begin Session -Seizure disorder, including, but not limited to epilepsy
Press Start/Pause button to confirm your choices and -If you have been taking any form of blood-thinning
start session. drug or psychoactive drug, such as, but not limited to
amphetamines, barbiturates, etc..
5 - End Session Important: The included sponges must be placed in the
NeuroFit will automatically shut down after the 20 or 30 electrodes to avoid possible skin burn or irritation.
minutes session time has lapsed (indicated by a short
“beep”). To end a session at any time, simply power *This device strictly forbidden (contraindicated) for
down the device by pressing the On/Off button for 3 people with pacemakers or implants of any kind.
seconds. If you have any inflammation, infection or scarring of
the skin, do not apply the electrodes on or near the
6- Pause/Resume affected areas. Consult with your doctor or health care
At any time you can pause your session by pressing the practitioner beforehand.
4 5
Keep out of reach of children. button to scroll through all the outputs; 0.5mA, 1.0mA,
1.5mA, 2.0mA.
Frequency of use 13. Begin Session
Scientific studies suggest that tDCS may be used 1 or 2 14. Press Start/Pause button to confirm your choices
times per day for no longer than 30 minutes. and start session.
How to use this device? 15. End Session
1. Insert sponges securely into each of the silicon 16. NeuroFit will automatically shut down
electrodes. (1 sponge per electrode) after the 20 or 30 minutes session time has lapsed
Important: The included sponges must be placed in the (indicated by a short “beep”). To end a session at any
electrodes to avoid possible skin burn or irritation. time, simply power down the device by pressing the
2. with sponges inserted, dip the electrodes into saline Start/Stop for 3 seconds.
(salt water) solution until the sponges are soaked. Saline -Pause/Resume: You can pause your session at any time
solution: 1/4 - 1/2 teaspoon of table salt per 8oz. of fresh by pressing the “Start/Pause” button. To resume your
water. session, press the “Start/Pause” button again.
3. Lightly squeeze out excess water. 17. When the session has ended, remove the electrodes
4. Connect the electrodes to the top of the machine. and place them on their support in the original packag-
5. Place the electrodes following the montage you ing. We recommended that you rinse the electrode
have chosen. Make sure there is as little hair as possible sponges with fresh water to remove the saline (salt).
between electrodes and skin.
6. Use the headband to hold the electrodes in place.
7. Press the ON/OFF button and hold for approximately Security
3 seconds until screen turns on. For comfort, efficiency and security tDCS devices
8. Select Session Time: generate ultra-low amounts of electricity through the
9. Press “T” to toggle the session timer between 20 or electrodes when placed on the surface of the skin. The
30 minutes. range is between 0.5mA to 2.0mA.
10. Select Output Level Replacement Batteries
11. Press “U” to increase output from 0.5mA up to The device works with an alkaline or standard 9V
2.0mA. The default output is set to the lowest setting, battery (included). When the battery indicator on the
0.5mA. This is where we recommend beginning each screen displays 1 bar, the battery should be replaced.
session. Use of other types of batteries may cause damage to the
12. Press D= Adjust the power down. device and will void the warranty.
*Tip: You can also continue pressing the “U” or “D”
6 7
Maintenance and Storage
This device must be stored in a place where the
temperature is between 40 - 80 degrees Fahrenheit. Used
batteries should be disposed of properly, in accordance
with local environmental laws,
Package Contents
8 9
dissolves. Problem: "Zap" sensation and/or flash-of-light at the
2- The wire set has two pin connectors (red and black). end of a session
Insert the pins securely into each of the rubber electrode Cause: This is normal at the end of a session. It is
holes. caused by the drop in conduction and is sensed by most
3- Connect the other end of the wire set securely into the users as a "zap" and/or a quick flash of light.
main unit. (port is located at the top of the device) Solution: If the above is uncomfortable, you may be
4- Insert 1 Yellow sponge securely into each of the able to minimize it by decreasing the output to the
rubber electrodes. lowest setting (0.5mA) 15 seconds before your session
5- With the sponges inserted, submerse the electrodes ends.
into the water for 20 seconds. Allow the water to saturate
the sponges. Problem: Where do I place the electrodes for my use?
6- Lightly squeeze out any excess water (so they are not We are unable suggest specific electrode placements
dripping). because it would be considered medical advice. We can,
7- Put on the headband on. however, direct you to information where community
8- Slide the electrodes under the headband. Note: While users have posted.
putting the electrodes in place, it is important to A place where you can ask specific questions about the
carefully part any hair that might be in the way. This will use of tDCS can be posted here:
allow the wet electrode sponges to make some skin https://www.reddit.com/r/tDCS/ .
contact. (some hair cover is expected, but just make sure Another resource is, http://tdcsplacements.com .
you part some of the hair and the sponges are wet
enough so that you can feel the water penetrate the hair).
9- Turn on the device and set the timer. Press Start. You
can adjust the output anytime during your session.
10- With the electrodes properly in place, the device will
complete its 20 or 30 minute cycle without stopping.
10 11