0% found this document useful (0 votes)
54 views8 pages

ZX-380B NeuroFit v2.0

This document provides instructions for using the NeuroFit tDCS device. It begins with safety notices, indicating the device is not FDA-regulated and no medical claims are made. It provides instructions on setup, electrode placement, session timing and output levels. Safety precautions for certain medical conditions are also described.

Uploaded by

Andrei Savva
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
0% found this document useful (0 votes)
54 views8 pages

ZX-380B NeuroFit v2.0

This document provides instructions for using the NeuroFit tDCS device. It begins with safety notices, indicating the device is not FDA-regulated and no medical claims are made. It provides instructions on setup, electrode placement, session timing and output levels. Safety precautions for certain medical conditions are also described.

Uploaded by

Andrei Savva
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 8

NeuroFit tDCS v2.

0
Power Up Your Brain. 20 Minutes Per Day.
Please Read This NOTICE Before Using
NeuroFit v2.0

NeuroFit is not a medical device and is not regulated by


the FDA. As such, it is not intended for use as a medical
diagnostic or therapeutic device, and
no medical claims of any sort are made for it. In no way
do we guarantee that this product will enhance or
sharpen your focus, memory skills or and other
cognitive ability. DO NOT USE THIS PRODUCT
without your health care practitioner’s guidance or if
you or any family member has ever experienced any
form of seizure disorder, including, but not limited to
epilepsy, or if you have been taking any form of
psychoactive drug, such as, but not limited to
amphetamines, barbiturates, etc..

*This device strictly forbidden (contraindicated) for


people with pacemakers or implants of any kind.
Please refer to the “precautions” in this manual.

Congratulations! You have just acquired NeuroFit.


The most advanced direct-to-consumer tDCS device on
the market today. Our latest v2.0 tDCS includes several
advancements that users have been asking for,
including; automatic “ramp-up AND “ramp-down”
capabilities at all times during a session (for comfort-
able use), backlight flicker switch (for nighttime
readability), end-of session beep indicator, and
upgraded electronics circuitry. These new features
vastly improve your tDCS device’s performance, as
well as your comfort level and usability.
1
Numerous studies have implied that tDCS can be a As new tDCS applications are actively studied in the
powerful tool for improving certain brain functions; academic and scientific circles, additional montages are
boost memory, reaction time, focus, energy, vigilance, posted with their respective results. For more informa-
etc. However, please note, the results of these studies, tion on montages, electrode positioning, studies & uses,
which are numerous, are considered “anecdotal” and you please refer to Totaltdcs.com. We actively update the site
must agree to perform your own due diligence and gain with links to the latest research data. Another source of
an understanding of tDCS before using. independent information is at the Reddit Community at
www.reddit.com/r/tdcs
NeuroFit is based on tDCS technology, and enhances it
with a sleek, new compact design, modernized
user-interface, on-board safety features & flexible user
options.
Unlike other rudimentary devices still being sold online,
NeuroFit has a 20/30 minute count-down timer - a very
important satfety feature that ensures you receive a
session that automatically ends & shuts down the device
in case you lose track of time or fall asleep
during use (this is a common occurrence!).

Another modern safety feature includes a sensor that


will automatically pause the device if the electrodes are
not being worn, or if they are applied incorrectly.

NeuroFit encompasses the latest technology and design,


while remaining true to the tDCS vision, which includes
numerous studies representing thousands of hours of
testing.

It is important to know that montages, where the


electrodes are placed, are the basis for the specific
benefit claims of tDCS.

2 3
Basic Operation “Start/Pause” button.
1- Power On The Device To resume your session, press the “Start/Pause” button
Press the ON/OFF button and hold for approximately again.
3 seconds until screen turns on.
Nighttime Use
2- Select Session Time: The screen’s backlight may be turned on momentarily
Press “T” to toggle the session timer between 20 or during a session. To do so, simply press ANY button
30 minutes. one time. The screen will light up for several seconds.
This will not affect your session time, output etc.
3- Select Output Level
Press “U” to increase output from 0.5mA up to Precautions (Also read the “NOTICE” above)
2.0mA. The default output is set to the lowest setting,
0.5mA. This is where we recommend beginning each Healthy adults can use this device.
session. In addition to the notice above, DO NOT use this device
Press D= Adjust the power down. until you have consulted with your doctor or health care
*Tip: You can also continue pressing the “U” or “D” practitioner, particularly if you have any of the
button to scroll through all the outputs; 0.5mA, 1.0mA, conditions below:
1.5mA, 2.0mA. -Bleeding tendency;
-Acute thrombosis.-
4- Begin Session -Seizure disorder, including, but not limited to epilepsy
Press Start/Pause button to confirm your choices and -If you have been taking any form of blood-thinning
start session. drug or psychoactive drug, such as, but not limited to
amphetamines, barbiturates, etc..
5 - End Session Important: The included sponges must be placed in the
NeuroFit will automatically shut down after the 20 or 30 electrodes to avoid possible skin burn or irritation.
minutes session time has lapsed (indicated by a short
“beep”). To end a session at any time, simply power *This device strictly forbidden (contraindicated) for
down the device by pressing the On/Off button for 3 people with pacemakers or implants of any kind.
seconds. If you have any inflammation, infection or scarring of
the skin, do not apply the electrodes on or near the
6- Pause/Resume affected areas. Consult with your doctor or health care
At any time you can pause your session by pressing the practitioner beforehand.
4 5
Keep out of reach of children. button to scroll through all the outputs; 0.5mA, 1.0mA,
1.5mA, 2.0mA.
Frequency of use 13. Begin Session
Scientific studies suggest that tDCS may be used 1 or 2 14. Press Start/Pause button to confirm your choices
times per day for no longer than 30 minutes. and start session.
How to use this device? 15. End Session
1. Insert sponges securely into each of the silicon 16. NeuroFit will automatically shut down
electrodes. (1 sponge per electrode) after the 20 or 30 minutes session time has lapsed
Important: The included sponges must be placed in the (indicated by a short “beep”). To end a session at any
electrodes to avoid possible skin burn or irritation. time, simply power down the device by pressing the
2. with sponges inserted, dip the electrodes into saline Start/Stop for 3 seconds.
(salt water) solution until the sponges are soaked. Saline -Pause/Resume: You can pause your session at any time
solution: 1/4 - 1/2 teaspoon of table salt per 8oz. of fresh by pressing the “Start/Pause” button. To resume your
water. session, press the “Start/Pause” button again.
3. Lightly squeeze out excess water. 17. When the session has ended, remove the electrodes
4. Connect the electrodes to the top of the machine. and place them on their support in the original packag-
5. Place the electrodes following the montage you ing. We recommended that you rinse the electrode
have chosen. Make sure there is as little hair as possible sponges with fresh water to remove the saline (salt).
between electrodes and skin.
6. Use the headband to hold the electrodes in place.
7. Press the ON/OFF button and hold for approximately Security
3 seconds until screen turns on. For comfort, efficiency and security tDCS devices
8. Select Session Time: generate ultra-low amounts of electricity through the
9. Press “T” to toggle the session timer between 20 or electrodes when placed on the surface of the skin. The
30 minutes. range is between 0.5mA to 2.0mA.
10. Select Output Level Replacement Batteries
11. Press “U” to increase output from 0.5mA up to The device works with an alkaline or standard 9V
2.0mA. The default output is set to the lowest setting, battery (included). When the battery indicator on the
0.5mA. This is where we recommend beginning each screen displays 1 bar, the battery should be replaced.
session. Use of other types of batteries may cause damage to the
12. Press D= Adjust the power down. device and will void the warranty.
*Tip: You can also continue pressing the “U” or “D”
6 7
Maintenance and Storage
This device must be stored in a place where the
temperature is between 40 - 80 degrees Fahrenheit. Used
batteries should be disposed of properly, in accordance
with local environmental laws,

Package Contents

Electronic Unit Control 1 unit Common Troubleshooting:


Connection Cable 1 unit
Batteries 1 9V Problem: Device does not turn on.
Silicon Electrodes 1 pair Solution: 2 possible solutions;
Sponges 2 pairs
1) Battery needs to be replaced. Insert a fresh 9 volt
Operating Manual 1 pc battery into the device.
Headband 1 pc 2) Push and hold power button for 2-3 seconds to boot
up the device.
We will happily help you with the operation of the device,
but please remember that we do not provide medical Problem: Stinging sensation when using the device.
advice, information about which tDCS electrode Solution: 2 Possible solutions.
placements will work for you, etc. Because this is a
hobby kit, it is up to you to do some groundwork by 1) Lower the output to 0.5mA until you are comfort-
reading the considerable amount of material available able with a higher setting.
online to decide if tDCS is right for you and what method 2) Slightly decrease the amount of salt in the saline
is of interest. A good starting point is at the Reddit solution.
Community at www.reddit.com/r/tdcs

Thank you again! Please follow the below to correct this;


Totaltdcs.com
1- Add 1 tsp of table salt to an 8 oz. glass of clean
lukewarm water and stir until the salt completely

8 9
dissolves. Problem: "Zap" sensation and/or flash-of-light at the
2- The wire set has two pin connectors (red and black). end of a session
Insert the pins securely into each of the rubber electrode Cause: This is normal at the end of a session. It is
holes. caused by the drop in conduction and is sensed by most
3- Connect the other end of the wire set securely into the users as a "zap" and/or a quick flash of light.
main unit. (port is located at the top of the device) Solution: If the above is uncomfortable, you may be
4- Insert 1 Yellow sponge securely into each of the able to minimize it by decreasing the output to the
rubber electrodes. lowest setting (0.5mA) 15 seconds before your session
5- With the sponges inserted, submerse the electrodes ends.
into the water for 20 seconds. Allow the water to saturate
the sponges. Problem: Where do I place the electrodes for my use?
6- Lightly squeeze out any excess water (so they are not We are unable suggest specific electrode placements
dripping). because it would be considered medical advice. We can,
7- Put on the headband on. however, direct you to information where community
8- Slide the electrodes under the headband. Note: While users have posted.
putting the electrodes in place, it is important to A place where you can ask specific questions about the
carefully part any hair that might be in the way. This will use of tDCS can be posted here:
allow the wet electrode sponges to make some skin https://www.reddit.com/r/tDCS/ .
contact. (some hair cover is expected, but just make sure Another resource is, http://tdcsplacements.com .
you part some of the hair and the sponges are wet
enough so that you can feel the water penetrate the hair).
9- Turn on the device and set the timer. Press Start. You
can adjust the output anytime during your session.
10- With the electrodes properly in place, the device will
complete its 20 or 30 minute cycle without stopping.

10 11
Certificate of Quality Warranty Card
NeuroFit v2.0 NeuroFit

Date of Purchase Purchase Location

Retailer’s Name Retailer Telephone Number

Retailer’s Address

Describe Issue with the Product

You might also like