Moshell Commands
Moshell Commands
6. To set Latitude/Longitude
Ø get sector lat
Ø set sector latitude <value>
9. To enable E1 supervision
Ø set
20. To autocreateCV
In RNC & RBS
Ø Get config
Ø Cv ls (2 CVs will be used for the autocreate CV function)
Ø Set “proxy” autoCreatedCVIsTurnedOn true/false
Ø Set timeForAutoCreatedCV (UTC time)
Ø Set timeForAutoCreatedCV 13:00 (cv autocreated at 9pm)
22. To create CV
In RNC,RXI & RBS
Ø cvms CXP9010373%1_R11G_050725_1516 emfauzi change_ntpserver_ip
Ø cvms CXP9010373%1_R11G_050725_1516 followed by comments for the CV
Ø cvset CXP9010373%1_R11G -- to set the CV startable
1 is slot 1
0 is slot 28
Ø port_0_dev_5 FU12
Ø port_1_dev_11 ASC
Ø Sec.2-port_4_dev_6 RU21
Ø port_4_dev_6 FU12
Ø port_5_dev_13 ASC
Ø Sec.3-port_8_dev_7 RU21
Ø port_8_dev_7 FU12
Ø port_9_dev_15 ASC
Ø
Ø 080408-13:32:58 10.109.246.153 7.0h RBS_NODE_MODEL_J_5_16 stopfile=/tmp/1052
Ø $ lhsh 001200/port_0_dev_4 fui get devstat
Ø Board: fuHw: Hw08P1, faultStatus: 0x0, temp: 47.0, sv: on, svTmaDegrad:
off, comp: on
Ø
Ø Dev1: mode: {ModeAuxTma}, feedPow: highPow
Ø capability: {vswrAntSv | tma19Sv | ulGainConf | maxUlGain}
Ø svCtrl: 0xe400, faultStatus: 0x0000
Ø txFreq: 882800, sensitivity: 49, gainUl: 4.0, volt: 16571.5,
curr: 84.0, dCycle: 0.0
Ø Dev2: mode: {ModeAuxTma}, feedPow: highPow
Ø capability: {resAntSv | tma19Sv | ulGainConf | maxUlGain}
Ø svCtrl: 0x2400, faultStatus: 0x0000
Ø txFreq: 0, sensitivity: 0, gainUl: 4.0, volt: 16565.9, curr:
90.4, dCycle: 0.0
3 sectors sample
USMLAP30> lhsh 001200/port_4_dev_5 fui get vswr
080521-03:26:13 10.108.243.9 7.0t RBS_NODE_MODEL_J_5_16 stopfile=/tmp/5952
$ lhsh 001200/port_4_dev_5 fui get vswr
vswr: -0.7[dB] <<<< result
37. redefine TD in VC
In RBS
Ø Resources for CELL does not come up – apparently TD is defined as U42
Ø lget AtmPort=MS-1-2-1,VplTp=vp1,VpcTp=1,VclTp=vc39
Ø lrset AtmPort=MS-1-2-1,VplTp=vp1,VpcTp=1,VclTp=vc39 atmTrafficDescriptorId
AtmTrafficDescriptor=C2P4000
Ø pr. Bq - must be win30
Ø pr aal2
Ø then get proxy for TransportNetwork=1,Aal2PathVccTp=ba1
Ø then lpr AtmPort=1-2-1,VplTp=vp1,VpcTp=1,VclTp=vc39
Ø get the proxy
Ø look for AtmTrafficDescriptor=C2P4000
In node
Ø lacc AtmPort=MS-27-1,VplTp=vp5 eteloopback
39. RBSID
In node RBS
Ø Pr iub
Ø Get the proxy NodeBFunction=1,Iub=POT3UU
Ø RBSID seen
In node RNC
Ø get iublink userlabel setomu
ARFCN 10637
DL Freq (MHz) 2127.4
UL Freq (MHz) 1937.4
In node RNC
Ø get allmmu_1 arf
Ø typical values (uarfcnDl 10662 & uarfcnUl 9712 )
In node RBS
Ø get antenna fq
Ø typical values (fqBandHighEdge 10712 & fqBandLowEdge 10612)
Ø thus if requested value at RNC is 10637 and if the value is between 10612 &
10712 at RBS, change only at RNC
In node RBS
Ø N
Ø Mon?
Ø TargetMonitor on disk: Yes
Ø TargetMonitor loaded: No
Ø TargetMonitor started: No
Ø Mon+
Ø te status Ans*
Ø to on NBAP trace
Ø te enable bus_send bus_receive NBAP
Ø to see if NBAP trace is ON or NOT
Ø te status NBAP
55. To check external Open Door alarm in RBS is set to which probable cause
In node RBS
Ø Pr almdevice
Ø Get proxy (either 2 / 1 or 9)
Ø Usually 9 for RBS door and 2 for BBU door
Ø Some put 1 for BBU door
Ø Get proxy for parameter check
Ø Lock proxy to change probableCause
Ø Bl 54
Ø probableCause 522 à power supply
Ø probableCause 118 à enclosure_door_open_m3100
Ø set 54 probableCause 118
Ø then unlock back proxy
Ø deb 54