KYL-813 User Manual
KYL-813 User Manual
, Ltd
Tel: +0086-755-86643962
Fax: +0086-755-83408785
Skype:rf-data
E_mail: [email protected]
Website: http://www.rf-data.com
(Ⅰ)Function
Schematic diagram
(Ⅱ)Performance Index
Characteristic Range Typical value Remarks
Power supply 9-15V 12V Output current>=500mA
Transmission 1-3km _ Open line- of- sight
distance
Output No. - 2 output -
Input type1 - Dry contact -
Input typeⅡ DC0-24V Low voltage<1V Low voltage -switch on
High voltage>4.5V High voltage-switch off
Transmission _ 300mA -
current
Receiving current - 30mA -
Size - 100mm*58mm*40mm -
(Ⅲ)Feature:
RF power: 500mW;
(Ⅲ)Parameter Setting
according to requirements,including:
triggered mode.
B.work channel:set the same channel for the modules that communicate
D. When it’s timer mode, you still need to set Host/Sub,Tx Time,Error,
Alarm time.
5)If KYL-813 is under acquisition mode, then user host only needs to
sending command.
1)work mode set Timer or triggered mode, 1 set switch/button can control alert light or engine
several miles away.
2)Sending input signal can be 1 set dip switch,button or high/low level voltage
3)Receiving output signal can drive alert light,moter,engine,electromagnetic valve or PLC.
Tel: +0086-755-86643962 E_mail: [email protected]; www.rf-data.com
Shenzhen KYL Communication Equipment Co., Ltd
4)Two KYL-813 communicate with each other,its ID and work channel must be the same.
2,Modbus host/slave networking mode
1)slave KYL-813 set acquisition mode,
2)Host is a PC or a touch screen that connects wireless transmission module
3)Host and KYL-813 use the same Modbus RTU protocol
4)Host must have the same work channel as KYL-813