Spesifikasi Fuji Japan Elevator Spek

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

JAPAN ELEVATOR- Sino japan joint venture

PT Laverton Protection Technologi


I Basic specification
1. Lift Name Passangger Elevator
630 Kgs / 5 Persons MRL motor caps 3.4 Kw
2. Capacity (kg)
800 Kgs/ 10 Persons MRL motor caps 4.6 Kw
3. Speed (m/s) 1
4. Drive VVVF
5. Control Selective Collective Control
6. Stops 2- 3 stops
7. Serving Floors 2- 3 Floors
8. Quantity 1 Unitt
9. Power Voltage 380V / AC
10. Lighting Voltage 220V / AC
11. Frequency 50HZ
12. Machine room NO
II Shaft
1. Shaft Construction Concrete
2250 (W) X 1900 (D)
2. Shaft Clear Dimensions
2250 x 2000
3. Travel 8000 - 12 000 mm

1
JAPAN ELEVATOR- Sino japan joint venture
4. Pit Depth 1500

5. Overhead Height
4500
III Car
6. Car Logo on COP JAPAN ELEVATOR Sino japan joint venture
1400 W X 1100 D
7. Car Size (mm*mm)
1400 x 1350
8. Opening size Center opening 800 (W) x 2100 (H)
9. Lighting Fluorescent
10. Car Flooring Povide )

11. Handrail Provide ( Type: stainless steel)


12. Mirror No
13. Emergency Exit ---
14. Lighting Fluorescent

15. Ventilation Low Noise Axial-Flow Fan


16. Car Wall Finishing hairline stainless steel
IV Car Operate Panel
1) COP face plate : LCD Full length
2) Alarm Button
The COP include 3) Open And Close Buzzer Automatic Door
1.
4) Lamp and Buzzer for Overload
5) Positon Indicator Digital Dot Matrix
6) Telephone Compartment

2
JAPAN ELEVATOR- Sino japan joint venture

V Car Door
1. Door operator VVVF

2. Door safety Infrared Light Curtain Protection


3. Car Door hairline stainless steel
VI Landing Door
1. Landing Door Material All floor Hairline stainless steel,
2. Jamb Specification Standard Narrow jamb
3. Jamb Material All floor stainless steel hire line l
VII Landing Fixtures
1. Hall Button Fuji Company advanced technique, hairline stainless steel, tiny button, record display with light
2. Fireman switch(separate) Key switch on COP
3. Position direction indicator AtHall Button Positon Indicator Digital Dot Matrix
Indicator position
4. At Hall Button

5. Door Call Group control type 2 in 1 Separate

VIII Main functions


Motor rotating speed can be prcisely adjusted to get smooth speed curve in elevator start travel
1. VVVF drive Yes
and stop and gain the sound comfort
VVVFdoor Motor rotating speed can be precisely adjusted to get the more gentle and sensitive door
2. Yes
operator machine start/stop.

3
JAPAN ELEVATOR- Sino japan joint venture
The elevator can not respond to outer calling ,but only respond to the command inside the car
3. Independent running Yes
through the action switch.
When the car is crowded with the passengers or the load is close to preset value,the car will
4. Automatic pass without stop Yes
automatically pass the calling landing in order to keep maximum travel efficiency.
Door-open time can be automatically adjust according to the difference between landing calling
5. Automatically adjust door opening time Yes
or car calling .
6. Reopen with hall call In the door shutting process,press reopen with hall call button can restart the door. Yes
When the elevator stops and opens the door ,press door- shut button, the door will be closed
7. Express door closing Yes
immediately.
The elevator decelerates and levels,the door only opens after the elevator comes to complete
8. Car stops and door open Yes
stop.
Arrival gong in the car top announces that the passengers arrive.
9. Car arrival gong Yes

It completely accords with distance principle with no crawling in the leveling ,It greatly
10. Direct Parking Yes
enhances the travel efficiency.
In the door open and shut period ,infrared light that covers the whole door height is used to
11. Photocell protection Yes
probe the door protection device of both the passengers and objects.
If the elevator can not open the door in the destination floor out of some reason,the elevator will
12. Designated stop Yes
close the door and travel to the next designated floor.
13. Overload holding stop When the car is overload ,the buzzer rings and stops the elevator in the same floor . Yes

14. Ait-stall timer protection The elevator stops operation due to slippery traction wire rope. Yes
15. Start protection control When the elevator enters into inspection operation,the car travels at inching running. Yes
The controller can record 62 latest troubles so as to quickly remove the trouble and restore the
16. Fault self-diagnosis Yes
elevator operation.
17. Repeated door closing If the elevator can not close the door due to certain obstacle or interference,the elevator will Yes

4
JAPAN ELEVATOR- Sino japan joint venture
reopen or re-shut the door until sundries are eliminated.
Up/down over-run and final limit The device can effectively prevent from the elevator's surging to the top or knocking the bottom
18. Yes
protection when it is out of control .It results in more safe and reliable elevator travel.
When the elevator down 1.3 times higher than the rated speed, this device will automatically cut
19. Down over-speed protection device off control mains,stop the motor running .safety tongs act to force the elevator stop in order to Yes
ensure safety .
When the elevator up speed is 1.3 times higher than rated speed,the device will automatically
20. Upward over-speed protection device Yes
decelerate or brake the elevator .
Micro-touch button for car call and hall Novel micro-touch button is used for operation panel command button in the car and landing
21. Yes
call calling button.
22. Floor and direction indicator inside car The car shows the elevator floor location and current travel direction. Yes
23. Floor and direction indicator in hall The landing shows the elevator floor location and current travel direction. Yes
Emergency car lighting automatically activated once power failure.
24. Yes
Emergency car lighting
When the elevator enters into emergency electric operation,the car travels at low speed inching
25. Inching running Yes
running.
Communication amid car car top elevator machine room well pit and rescue duty room through
26. Five way inter com Yes
walkie-talkie.
In emergency conditions,if bell button above car operation panel is continuously
27. Bell Yes
pressed,electric bell rings on top of in the car.
If you start key switch in main landing or monitor screen,all the callings will be cancelled,the
28. Fire emergency return elevator directly and immediately drives to the designated rescue landing and automatically Yes
opens the door.
Car ventilation, If there is no calling or command signal within the stipulated time,the car fan and lighting will
29. Yes
Light automatic shut off be automatically closed in order to save the energy.

5
JAPAN ELEVATOR- Sino japan joint venture
The elevator can be called to main landing (after finishing the service) through the key switch
30. Remote Shut-off Yes
and automatically exists the service.

31. Included ARD


32. Garansi spare part 1 thn & Free service 6 bulan

You might also like