0% found this document useful (0 votes)
66 views23 pages

Control Techniques EU 20191781 Ecodesign Regulation - Energy Efficiency Indicators Issue 4

This document provides energy efficiency indicators for Control Techniques variable speed drives, as required by the EU 2019/1781 Ecodesign Regulation. Tables show power losses as a percentage of apparent power at various operating points, including standby, for different drive product lines. All drives listed meet the minimum IE2 efficiency level. The maximum operating temperature and frequency range are also specified.

Uploaded by

arturo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
0% found this document useful (0 votes)
66 views23 pages

Control Techniques EU 20191781 Ecodesign Regulation - Energy Efficiency Indicators Issue 4

This document provides energy efficiency indicators for Control Techniques variable speed drives, as required by the EU 2019/1781 Ecodesign Regulation. Tables show power losses as a percentage of apparent power at various operating points, including standby, for different drive product lines. All drives listed meet the minimum IE2 efficiency level. The maximum operating temperature and frequency range are also specified.

Uploaded by

arturo
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 23

Control Techniques Drives

EU 2019/1781 Ecodesign
Regulation Energy Efficiency
Indicators
Variable Speed AC drives for Induction Motors

Issue: 4
Contents

1. Introduction .................................................................................................................................................... 2
2. Energy Efficiency - % of Apparent Power .............................................................................................. 4
Table 1-1 Digitax HD M75x..................................................................................................................... 4
Table 1-2 Commander C200/C300/M400/HS30 (Frame 1 – 4) ....................................................... 5
Table 1-3 Unidrive E300/M600/M70x/M88x, Commander C200/C300 (Frame 5 – 9) ................ 6
Table 1-4 Powerdrive F300, Pump F600, HVAC H300 .................................................................... 9
Table 1-5 Commander S100 ................................................................................................................ 12
3. Power Losses .............................................................................................................................................. 14
Table 2-1 Digitax HD M75x................................................................................................................... 14
Table 2-2 Commander C200/C300/M400/HS30 (Frame 1 – 4) ..................................................... 15
Table 2-3 Unidrive E300/HS7x/M600/M70x/M88x, Commander C200/C300 (Frame 5 – 9) ... 16
Table 2-4 Powerdrive F300, Pump F600, HVAC H300 .................................................................. 19
Table 2-5 Commander S100 ................................................................................................................ 22

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 1
1. Introduction

• The European Commission Regulation EU 2019/1781, known as the ‘Ecodesign Regulation’


establishes an energy efficiency framework for a range of three-phase electric motors and variable
speed drives.
• The goal of the regulation is to achieve energy saving through the design of better energy related
product, leading to a more sustainable future and economic saving for end users and businesses.
• The latest regulation (phase 1), which came into effect in 2019 (1st July for 2021 for VSDs), covers
all AC induction motors and variable speed drives in the power range of 0.12 kW up to 1000 kW
and with a voltage between 100 V and 1000 V.
• A second phase is scheduled for 1st July 2023, which will expand the scope of the regulation and
will increase the requirements on motors.
• For variable speed drives, the latest regulation requires a minimum efficiency of IE2.
• Control Techniques products will show the efficiency rating at the nominal operating point on their
rating label and this document contains all efficiency/operating points required by the regulation for
the following product ranges:
o Digitax HD M75x
o Commander C200 & 300
o Unidrive HSxx
o Unidrive Mxxx
o Unidrive E300
o Unidrive Fxxx
o Unidrive Hxxx
o Commander S100
• The maximum operating temperature of Control Techniques products listed in this document is:

Product Range Maximum Operating Temperature (°C)


Digitax HD M75x
Unidrive E300/M600/M70x/M88x 55
Commander C200/C300 (Frame 5 – 9)
Commander C200/C300/M400/HS30 (Frame 1 – 4)
60
Commander S100

• The frequency range of Control Techniques products listed in this document is 45 to 66 Hz.
• Measurements are made with a supply frequency of 50 Hz and a switching frequency of 4 kHz
(rated power up to and including 90 kW), or 2 kHz (rated power above 90 kW).
• Power Loss values quoted for energy efficiency are given as a percentage of apparent power
(1.732 x Drive Rated Current x Drive Rated Voltage).
• The IE Class is determined by the power losses measured with the variable speed drive operating
at 90 % rated output frequency and at 100 % rated torque. A variable speed drive meets the IE2
efficiency level, if the losses are at least 25 % lower than the losses of a reference variable speed
drive defined within the regulation.
• Additional operating points are also defined at different combinations of torque and speed, at
which power losses are to be determined. The purpose of these points is to reflect the losses at
part load for both variable and constant torque applications. Standby losses are also measured.

Operating point for Relative motor stator frequency Torque producing current*
measured power loss (%) (%)
Standby 0 0
1 25 25
2 25 50
3 25 100
4 50 25
5 50 50
6 50 100
7 90 50
8 90 100
*Based on typical motor ratings per size of drive.

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 2
The name and address of the manufacturer is listed below:

Manufacturer
Nidec Control Techniques Ltd
The Gro
Newtown
Powys
SY16 3BE
UK

Registered in England and Wales.


Company Reg. No. 01236886

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 3
2. Energy Efficiency - % of Apparent Power

Table 1-1 Digitax HD M75x


Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated
(% of Apparent Output Power) Rated Supply
Efficiency Efficiency Model Output Motor Output
Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current
(V)
[0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
0.3 0.7 1.0 1.5 0.5 1.1 1.9 1.2 2.1 97.6 IE2 01200022 0.76 0.37 2.2 200 to 240 +10%
0.2 0.7 1.0 1.5 0.5 1.1 1.9 1.2 2.1 97.6 IE2 01200040 1.39 0.75 4 200 to 240 +10%
0.1 0.7 0.9 1.4 0.5 1.1 1.8 1.2 2.0 97.6 IE2 01200065 2.25 1.1 6.5 200 to 240 +10%
0.1 0.4 0.5 1.2 0.4 0.8 1.3 0.6 1.7 97.7 IE2 02200090 3.12 2.2 9 200 to 240 +10%
0.1 0.4 0.5 1.2 0.4 0.8 1.3 0.6 1.7 97.7 IE2 02200120 4.16 2.2 12 200 to 240 +10%
0.0 0.5 0.7 1.3 0.6 1.1 1.2 1.2 2.1 97.3 IE2 03200160 5.54 4 16 200 to 240 +10%
0.6 0.6 0.6 1.2 0.4 0.7 1.2 1.3 1.7 97.9 IE2 01400015 1.04 0.37 1.5 380 to 480 +10%
0.3 0.6 0.6 1.2 0.4 0.6 1.2 1.3 1.7 97.9 IE2 01400030 2.08 0.75 3 380 to 480 +10%
0.2 0.5 0.5 1.0 0.3 0.5 1.0 1.1 1.4 97.9 IE2 01400042 2.91 1.5 4.2 380 to 480 +10%
0.1 0.3 0.3 0.8 0.3 0.6 0.9 0.7 1.9 97.7 IE2 02400060 4.16 2.2 6 380 to 480 +10%
0.1 0.3 0.3 0.8 0.3 0.6 0.9 0.7 1.9 97.7 IE2 02400080 5.54 3 8 380 to 480 +10%
0.1 0.3 0.3 0.8 0.3 0.6 0.9 0.7 1.9 97.7 IE2 02400105 7.27 4 10.5 380 to 480 +10%
0.1 0.3 0.2 0.7 0.2 0.5 0.7 0.6 1.5 97.7 IE2 03400135 9.35 5.5 13.5 380 to 480 +10%
0.0 0.3 0.3 0.8 0.3 0.6 0.9 0.7 1.9 97.7 IE2 03400160 11.09 5.5 16 380 to 480 +10%

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 4
Table 1-2 Commander C200/C300/M400/HS30 (Frame 1 – 4)
Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated
(% of Apparent Output Power) Rated Supply
Efficiency Efficiency Model Output Motor Output
Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current
(V)
[0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
0.9 1.6 2.0 2.8 1.9 2.1 3.4 2.4 3.7 95.8 IE2 01200017 0.59 0.25 1.7 200 to 240 +10%
0.7 1.6 2.0 2.8 1.9 2.1 3.4 2.4 3.7 95.8 IE2 01200024 0.83 0.37 2.4 200 to 240 +10%
0.5 1.6 2.0 2.8 1.9 2.1 3.4 2.4 3.7 95.8 IE2 01200033 1.14 0.55 3.3 200 to 240 +10%
0.4 1.4 1.6 2.3 1.6 1.8 2.8 2.0 3.1 95.8 IE2 01200042 1.45 0.75 4.2 200 to 240 +10%
0.5 2.0 1.9 3.3 1.9 2.0 2.9 2.4 3.6 95.9 IE2 02200024 0.83 0.37 2.4 200 to 240 +10%
0.9 0.9 1.2 2.0 0.9 1.1 1.9 1.4 2.5 97.5 IE2 02200033 1.14 0.55 3.3 200 to 240 +10%
0.7 0.9 1.2 2.0 0.9 1.1 1.9 1.4 2.5 97.5 IE2 02200042 1.45 0.75 4.2 200 to 240 +10%
0.5 0.9 1.2 2.0 0.9 1.1 1.9 1.4 2.5 97.5 IE2 02200056 1.94 1.1 5.6 200 to 240 +10%
0.4 0.8 1.0 1.6 0.7 0.9 1.6 1.2 2.1 97.5 IE2 02200075 2.60 1.5 7.5 200 to 240 +10%
0.3 0.6 1.2 1.4 0.9 1.1 1.3 1.3 2.1 97.5 IE2 03200100 3.46 2.2 10 200 to 240 +10%
0.2 0.6 0.8 1.7 0.7 0.9 1.6 1.0 2.3 97.6 IE2 04200133 4.61 3 13.3 200 to 240 +10%
0.2 0.5 0.6 1.4 0.6 0.7 1.3 0.8 1.9 97.6 IE2 04200176 6.10 4 17.6 200 to 240 +10%
0.9 1.0 1.1 1.4 0.9 1.1 1.6 1.4 2.1 97.7 IE2 02400013 0.90 0.37 1.3 380 to 480 +10%
0.7 1.0 1.1 1.4 0.9 1.1 1.6 1.4 2.1 97.7 IE2 02400018 1.25 0.55 1.8 380 to 480 +10%
0.5 1.0 1.1 1.4 0.9 1.1 1.6 1.4 2.1 97.7 IE2 02400023 1.59 0.75 2.3 380 to 480 +10%
0.4 1.0 1.1 1.4 0.9 1.1 1.6 1.4 2.1 97.7 IE2 02400032 2.22 1.1 3.2 380 to 480 +10%
0.3 0.9 0.9 1.2 0.8 1.0 1.4 1.2 1.9 97.7 IE2 02400041 2.84 1.5 4.1 380 to 480 +10%
0.3 0.4 0.6 1.1 0.1 0.5 1.1 0.4 1.2 98.3 IE2 03400056 3.88 2.2 5.6 380 to 480 +10%
0.2 0.4 0.6 1.1 0.1 0.5 1.1 0.4 1.2 98.3 IE2 03400073 5.06 3 7.3 380 to 480 +10%
0.2 0.4 0.5 1.0 0.1 0.5 1.0 0.4 1.1 98.3 IE2 03400094 6.51 4 9.4 380 to 480 +10%
0.1 0.4 0.6 1.0 0.6 0.6 1.1 1.1 1.6 98.1 IE2 04400135 9.35 5.5 13.5 380 to 480 +10%
0.1 0.4 0.5 0.9 0.5 0.5 1.0 0.9 1.4 98.1 IE2 04400170 11.78 7.5 17 380 to 480 +10%

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 5
Table 1-3 Unidrive E300/M600/M70x/M88x, Commander C200/C300 (Frame 5 – 9)
Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated
(% of Apparent Output Power) Rated Supply
Efficiency Efficiency Model Output Motor Output
Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current
(V)
[0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
1.0 1.0 1.5 2.2 0.8 1.4 2.1 1.4 2.3 97.5 IE2 03200050 1.73 0.75 5 200 to 240 +10%
0.7 1.0 1.5 2.2 0.8 1.4 2.1 1.4 2.3 97.5 IE2 03200066 2.29 1.1 6.6 200 to 240 +10%
0.6 1.0 1.5 2.2 0.8 1.4 2.1 1.4 2.3 97.5 IE2 03200080 2.77 1.5 8 200 to 240 +10%
0.5 0.8 1.2 1.8 0.7 1.2 1.8 1.1 1.8 97.5 IE2 03200106 3.67 2.2 10.6 200 to 240 +10%
0.4 0.9 1.2 2.8 1.1 1.3 2.5 1.2 2.8 97.0 IE2 04200137 4.75 3 13.7 200 to 240 +10%
0.3 0.7 0.9 2.2 0.9 1.1 2.0 0.9 2.2 97.0 IE2 04200185 6.41 4 18.5 200 to 240 +10%
0.3 0.9 1.2 2.0 0.9 1.6 2.8 1.8 4.4 97.5 IE2 05200250 8.66 5.5 25 200 to 240 +10%
0.2 0.6 1.0 1.5 0.8 0.9 1.6 1.2 2.5 97.4 IE2 06200330 11.43 7.5 33 200 to 240 +10%
0.1 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 06200440 15.24 11 44 200 to 240 +10%
0.1 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 07200610 21.13 15 61 200 to 240 +10%
0.1 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 07200750 25.98 18.5 75 200 to 240 +10%
0.1 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 07200830 28.75 22 83 200 to 240 +10%
0.1 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 08201160 40.18 30 116 200 to 240 +10%
0.0 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 08201320 45.73 37 132 200 to 240 +10%
0.0 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 09201760 60.97 45 176 200 to 240 +10%
0.0 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 09202190 75.86 55 219 200 to 240 +10%
0.0 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 10202830 98.03 75 283 200 to 240 +10%
0.0 0.5 0.8 1.2 0.6 0.7 1.2 1.0 2.0 97.4 IE2 10203000 103.92 90 300 200 to 240 +10%
1.1 0.8 1.1 1.5 0.5 1.1 1.6 1.2 2.0 97.5 IE2 03400025 1.73 0.75 2.5 380 to 480 +10%
0.9 0.8 1.1 1.5 0.5 1.1 1.6 1.2 2.0 97.5 IE2 03400031 2.15 1.1 3.1 380 to 480 +10%
0.6 0.8 1.1 1.5 0.5 1.1 1.6 1.2 2.0 97.5 IE2 03400045 3.12 1.5 4.5 380 to 480 +10%
0.4 0.8 1.1 1.5 0.5 1.1 1.6 1.2 2.0 97.5 IE2 03400062 4.30 2.2 6.2 380 to 480 +10%
0.3 0.8 1.1 1.5 0.5 1.1 1.6 1.2 2.0 97.5 IE2 03400078 5.40 3 7.8 380 to 480 +10%
0.3 0.8 1.1 1.5 0.5 1.1 1.6 1.2 2.0 97.5 IE2 03400100 6.93 4 10 380 to 480 +10%
0.2 0.4 0.6 1.3 0.5 0.9 1.3 0.9 1.8 97.8 IE2 04400150 10.39 5.5 15 380 to 480 +10%
0.2 0.4 0.7 1.5 0.6 1.1 1.5 1.0 2.1 97.8 IE2 04400172 11.92 7.5 17.2 380 to 480 +10%
0.1 0.4 0.5 0.9 0.4 0.7 1.2 0.8 1.9 97.5 IE2 05400220 15.24 9 22 380 to 480 +10%
0.1 0.4 0.6 0.9 0.4 0.7 1.3 0.8 2.0 97.5 IE2 05400270 18.71 11 27 380 to 480 +10%
0.1 0.4 0.5 0.9 0.4 0.7 1.2 0.8 1.9 97.5 IE2 05400300 20.78 15 30 380 to 480 +10%
0.1 0.4 0.5 1.1 0.4 0.8 1.5 0.6 2.1 97.0 IE2 06400350 24.25 15 35 380 to 480 +10%
0.1 0.5 0.8 1.6 0.6 1.1 2.1 0.9 3.1 97.0 IE2 06400420 29.10 18.5 42 380 to 480 +10%
0.1 0.5 0.8 1.6 0.6 1.1 2.1 0.9 3.1 97.0 IE2 06400470 32.56 22 47 380 to 480 +10%
0.1 0.3 0.5 0.6 0.3 0.5 1.2 0.8 0.9 98.7 IE2 07400660 45.73 30 66 380 to 480 +10%
0.1 0.3 0.5 0.6 0.3 0.5 1.2 0.8 0.9 98.7 IE2 07400770 53.35 37 77 380 to 480 +10%
0.1 0.3 0.5 0.6 0.3 0.5 1.2 0.8 0.9 98.7 IE2 07401000 69.28 45 100 380 to 480 +10%
Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators
Issue Number 4 6
Table 1-3 Unidrive E300/M600/M70x/M88x, Commander C200/C300 (Frame 5 – 9) continued
Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated
(% of Apparent Output Power) Rated Supply
Efficiency Efficiency Model Output Motor Output
Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current
(V)
[0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
0.1 0.3 0.5 0.6 0.3 0.5 1.2 0.8 0.9 98.7 IE2 08401340 92.84 55 134 380 to 480 +10%
0.0 0.3 0.5 0.6 0.3 0.5 1.2 0.8 0.9 98.7 IE2 08401570 108.77 75 157 380 to 480 +10%
0.0 0.8 1.1 1.9 0.9 1.1 2.0 1.2 1.9 97.5 IE2 09402000 138.56 90 200 380 to 480 +10%
0.0 0.8 1.1 1.9 0.9 1.1 2.0 1.2 1.9 97.5 IE2 09402240 155.19 110 224 380 to 480 +10%
0.0 0.5 0.7 1.2 0.6 0.7 1.3 0.8 1.2 97.5 IE2 10402700 187.06 132 270 380 to 480 +10%
0.0 0.6 0.9 1.6 0.7 0.9 1.7 1.0 1.6 97.5 IE2 10403200 221.70 160 320 380 to 480 +10%
0.0 0.8 0.9 0.9 0.9 0.8 1.3 1.1 0.9 98.7 IE2 11403770 261.19 185 377 380 to 480 +10%
0.0 0.8 0.9 0.9 0.9 0.8 1.3 1.1 0.9 98.7 IE2 11404170 288.91 200 417 380 to 480 +10%
0.0 0.8 0.9 0.9 0.9 0.8 1.3 1.1 0.9 98.7 IE2 11404640 321.47 250 464 380 to 480 +10%
0.7 1.0 0.4 0.5 1.0 0.6 1.1 98.0 IE2 12404800 332.55 250 480 380 to 480 +10%
0.6 1.0 0.4 0.5 1.0 0.6 1.1 98.0 IE2 12405660 392.14 315 566 380 to 480 +10%
0.5 1.0 0.4 0.5 1.0 0.6 1.1 98.0 IE2 12406600 457.26 355 660 380 to 480 +10%
0.5 1.0 0.4 0.5 1.0 0.6 1.1 98.0 IE2 12407200 498.83 400 720 380 to 480 +10%
0.8 0.6 1.0 2.2 0.9 1.6 2.2 1.5 3.0 97.8 IE2 05500030 2.99 1.5 3 500 to 575 +10%
0.6 0.8 1.1 1.9 0.8 1.3 2.2 1.4 2.6 97.8 IE2 05500040 3.98 2.2 4 500 to 575 +10%
0.3 0.8 1.0 1.8 0.7 1.2 2.1 1.3 2.5 97.8 IE2 05500069 6.87 4 6.9 500 to 575 +10%
0.3 0.7 0.9 1.5 0.6 1.0 1.7 1.1 2.1 97.8 IE2 06500100 9.96 5.5 10 500 to 575 +10%
0.2 0.6 0.8 1.4 0.6 1.0 1.6 1.0 2.0 97.8 IE2 06500150 14.94 7.5 15 500 to 575 +10%
0.1 0.6 0.8 1.3 0.6 0.9 1.5 1.0 1.8 97.8 IE2 06500190 18.92 11 19 500 to 575 +10%
0.1 0.6 0.8 1.3 0.6 0.9 1.5 1.0 1.8 97.8 IE2 06500230 22.91 15 23 500 to 575 +10%
0.1 0.7 0.9 1.5 0.6 1.0 1.7 1.1 2.1 97.8 IE2 06500290 28.88 18.5 29 500 to 575 +10%
0.1 0.7 1.0 1.6 0.7 1.1 2.1 1.3 1.8 98.1 IE2 06500350 34.86 22 35 500 to 575 +10%
0.1 0.7 0.9 1.5 0.6 1.0 1.8 1.1 2.1 97.8 IE2 07500440 43.82 30 44 500 to 575 +10%
0.1 0.6 0.8 1.3 0.5 0.9 1.5 1.0 1.8 97.8 IE2 07500550 54.78 37 55 500 to 575 +10%
0.1 0.8 1.1 1.8 0.8 1.2 2.1 1.3 2.5 97.8 IE2 08500630 62.74 45 63 500 to 575 +10%
0.1 0.8 1.1 1.8 0.8 1.2 2.1 1.4 2.5 97.8 IE2 08500860 85.65 55 86 500 to 575 +10%
0.1 0.6 0.7 1.3 0.5 0.9 1.5 0.9 1.8 97.8 IE2 09501040 103.58 75 104 500 to 575 +10%
0.0 0.5 0.8 1.2 0.5 0.8 1.6 1.0 1.3 98.1 IE2 09501310 130.47 90 131 500 to 575 +10%
0.0 0.5 0.7 1.1 0.5 0.7 1.5 0.9 1.3 98.1 IE2 10501520 151.38 110 152 500 to 575 +10%
0.0 0.4 0.7 1.0 0.5 0.7 1.4 0.8 1.2 98.1 IE2 10501900 189.23 132 190 500 to 575 +10%
0.0 0.5 0.8 1.2 0.5 0.8 1.6 1.0 1.4 98.1 IE2 11502000 199.19 150 200 500 to 575 +10%
0.0 0.5 0.8 1.2 0.5 0.8 1.6 1.0 1.4 98.1 IE2 11502540 252.97 185 254 500 to 575 +10%
0.0 0.5 0.8 1.2 0.5 0.8 1.6 1.0 1.4 98.1 IE2 11502850 283.84 225 285 500 to 575 +10%

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 7
Table 1-3 Unidrive E300/M600/M70x/M88x, Commander C200/C300 (Frame 5 – 9) continued
Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated
(% of Apparent Output Power) Rated Supply
Efficiency Efficiency Model Output Motor Output
Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current
(V)
[0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
0.2 0.6 0.8 1.3 0.5 0.9 1.5 1.0 1.8 97.8 IE2 07600190 22.71 15 19 500 to 690 +10%
0.2 0.6 0.7 1.2 0.5 0.9 1.4 0.9 1.7 97.8 IE2 07600240 28.68 18.5 24 500 to 690 +10%
0.1 0.6 0.7 1.2 0.5 0.8 1.4 0.9 1.7 97.8 IE2 07600290 34.66 22 29 500 to 690 +10%
0.1 0.6 0.8 1.3 0.5 0.9 1.5 1.0 1.8 97.8 IE2 07600380 45.41 30 38 500 to 690 +10%
0.1 0.6 0.7 1.3 0.5 0.9 1.5 0.9 1.8 97.8 IE2 07600440 52.59 37 44 500 to 690 +10%
0.1 0.5 0.7 1.1 0.5 0.8 1.3 0.8 1.6 97.8 IE2 07600540 64.54 45 54 500 to 690 +10%
0.1 0.7 0.9 1.5 0.6 1.0 1.7 1.1 2.1 97.8 IE2 08600630 75.29 55 63 500 to 690 +10%
0.0 0.7 0.9 1.5 0.6 1.0 1.8 1.1 2.1 97.8 IE2 08600860 102.78 75 86 500 to 690 +10%
0.0 0.4 0.6 1.0 0.4 0.7 1.3 0.8 1.1 98.1 IE2 09601040 124.29 90 104 500 to 690 +10%
0.0 0.4 0.6 1.0 0.4 0.7 1.3 0.8 1.1 98.1 IE2 09601310 156.56 110 131 500 to 690 +10%
0.0 0.4 0.6 1.0 0.5 0.7 1.4 0.8 1.1 98.1 IE2 10601500 179.27 132 150 500 to 690 +10%
0.0 0.4 0.6 1.0 0.4 0.6 1.3 0.8 1.1 98.1 IE2 10601780 212.73 160 178 500 to 690 +10%
0.0 0.5 0.7 1.1 0.5 0.7 1.4 0.9 1.2 98.1 IE2 11602100 250.97 185 210 500 to 690 +10%
0.0 0.5 0.7 1.1 0.5 0.7 1.4 0.9 1.2 98.1 IE2 11602380 284.44 200 238 500 to 690 +10%
0.0 0.5 0.7 1.1 0.5 0.7 1.5 0.9 1.2 98.1 IE2 11602630 314.32 250 263 500 to 690 +10%

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 8
Table 1-4 Powerdrive F300, Pump F600, HVAC H300
Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated
(% of Apparent Output Power) Rated Supply
Efficiency Efficiency Model Output Motor Output
Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current
(V)
[0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
0.7 0.7 1.1 1.7 0.6 1.1 1.6 1.1 1.7 97.5 IE2 03200066 2.29 1.1 6.6 200 to 240 +10%
0.6 0.8 1.2 1.8 0.7 1.2 1.8 1.2 1.9 97.5 IE2 03200080 2.77 1.5 8 200 to 240 +10%
0.4 0.7 1.1 1.6 0.6 1.0 1.6 1.0 1.6 97.5 IE2 03200110 3.81 2.2 11 200 to 240 +10%
0.4 0.7 1.0 1.5 0.5 1.0 1.5 1.0 1.5 97.5 IE2 03200127 4.40 3 12.7 200 to 240 +10%
0.3 0.7 0.9 2.1 0.8 1.0 1.9 0.9 2.1 97.0 IE2 04200180 6.24 4 18 200 to 240 +10%
0.2 0.5 0.7 1.6 0.6 0.8 1.5 0.7 1.6 97.0 IE2 04200250 8.66 5.5 25 200 to 240 +10%
0.2 0.7 1.0 1.7 0.8 1.3 2.3 1.5 3.7 97.5 IE2 05200300 10.39 7.5 30 200 to 240 +10%
0.1 0.4 0.7 1.0 0.5 0.6 1.0 0.8 1.6 97.4 IE2 06200500 17.32 11 50 200 to 240 +10%
0.1 0.4 0.6 0.9 0.5 0.6 0.9 0.7 1.5 97.4 IE2 06200580 20.09 15 58 200 to 240 +10%
0.1 0.4 0.6 1.0 0.5 0.6 1.0 0.8 1.6 97.4 IE2 07200750 25.98 18.5 75 200 to 240 +10%
0.1 0.4 0.6 1.0 0.5 0.6 1.0 0.8 1.6 97.4 IE2 07200940 32.56 22 94 200 to 240 +10%
0.0 0.4 0.6 0.9 0.4 0.5 0.9 0.7 1.4 97.4 IE2 07201170 40.53 30 117 200 to 240 +10%
0.0 0.4 0.6 1.0 0.5 0.6 1.0 0.8 1.5 97.4 IE2 08201490 51.62 37 149 200 to 240 +10%
0.0 0.4 0.6 0.9 0.5 0.5 0.9 0.7 1.5 97.4 IE2 08201800 62.35 45 180 200 to 240 +10%
0.0 0.4 0.6 1.0 0.5 0.6 1.0 0.8 1.6 97.4 IE2 09202160 74.82 55 216 200 to 240 +10%
0.0 0.4 0.6 1.0 0.5 0.6 1.0 0.8 1.6 97.4 IE2 09202660 92.15 75 266 200 to 240 +10%
0.0 0.4 0.7 1.1 0.5 0.6 1.1 0.8 1.7 97.4 IE2 10203250 112.58 90 325 200 to 240 +10%
0.0 0.4 0.7 1.0 0.5 0.6 1.0 0.8 1.7 97.4 IE2 10203600 124.71 110 360 200 to 240 +10%
0.8 0.6 0.8 1.1 0.4 0.8 1.2 0.8 1.5 97.5 IE2 03400034 2.36 1.1 3.4 380 to 480 +10%
0.6 0.6 0.8 1.0 0.4 0.7 1.1 0.8 1.4 97.5 IE2 03400045 3.12 1.5 4.5 380 to 480 +10%
0.4 0.6 0.8 1.1 0.4 0.8 1.2 0.8 1.4 97.5 IE2 03400062 4.30 2.2 6.2 380 to 480 +10%
0.4 0.7 0.9 1.2 0.4 0.9 1.3 0.9 1.6 97.5 IE2 03400077 5.33 3 7.7 380 to 480 +10%
0.3 0.6 0.8 1.1 0.4 0.8 1.2 0.9 1.5 97.5 IE2 03400104 7.21 4 10.4 380 to 480 +10%
0.2 0.6 0.9 1.2 0.4 0.9 1.3 0.9 1.6 97.5 IE2 03400123 8.52 5.5 12.3 380 to 480 +10%
0.1 0.3 0.5 1.1 0.4 0.7 1.0 0.7 1.4 97.8 IE2 04400185 12.82 7.5 18.5 380 to 480 +10%
0.1 0.3 0.5 1.1 0.4 0.8 1.0 0.7 1.5 97.8 IE2 04400240 16.63 11 24 380 to 480 +10%
0.1 0.4 0.5 0.8 0.4 0.7 1.2 0.7 1.8 97.5 IE2 05400300 20.78 15 30 380 to 480 +10%
0.1 0.4 0.5 0.9 0.4 0.7 1.2 0.7 1.9 97.5 IE2 05400310 21.48 15 31 380 to 480 +10%
0.1 0.3 0.5 1.0 0.4 0.7 1.3 0.6 2.0 97.0 IE2 06400380 26.33 18.5 38 380 to 480 +10%
0.1 0.5 0.7 1.4 0.5 1.0 1.8 0.8 2.7 97.0 IE2 06400480 33.26 22 48 380 to 480 +10%
0.1 0.4 0.6 1.2 0.4 0.8 1.6 0.6 2.3 97.0 IE2 06400630 43.65 30 63 380 to 480 +10%
0.1 0.2 0.4 0.5 0.2 0.4 1.0 0.7 0.8 98.7 IE2 07400790 54.73 37 79 380 to 480 +10%
0.1 0.2 0.4 0.5 0.2 0.4 1.0 0.6 0.7 98.7 IE2 07400940 65.13 45 94 380 to 480 +10%
0.1 0.3 0.4 0.5 0.2 0.5 1.1 0.7 0.8 98.7 IE2 07401120 77.60 55 112 380 to 480 +10%

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 9
Table 1-4 Powerdrive F300, Pump F600, HVAC H300 continued
Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated
(% of Apparent Output Power) Rated Supply
Efficiency Efficiency Model Output Motor Output
Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current
(V)
[0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
0.0 0.2 0.4 0.5 0.2 0.4 1.0 0.7 0.8 98.7 IE2 08401550 107.39 75 155 380 to 480 +10%
0.0 0.2 0.4 0.5 0.2 0.4 1.0 0.7 0.8 98.7 IE2 08401840 127.48 90 184 380 to 480 +10%
0.0 0.7 1.0 1.7 0.8 1.0 1.8 1.1 1.7 97.5 IE2 09402210 153.11 110 221 380 to 480 +10%
0.0 0.6 0.9 1.6 0.7 0.9 1.7 1.0 1.6 97.5 IE2 09402660 184.29 132 266 380 to 480 +10%
0.0 0.4 0.6 1.0 0.5 0.6 1.1 0.7 1.0 97.5 IE2 10403200 221.70 160 320 380 to 480 +10%
0.0 0.6 0.8 1.4 0.6 0.8 1.5 0.9 1.4 97.5 IE2 10403610 250.11 200 361 380 to 480 +10%
0.0 0.7 0.8 0.8 0.8 0.7 1.1 0.9 0.7 98.7 IE2 11404370 302.76 225 437 380 to 480 +10%
0.0 0.7 0.8 0.8 0.8 0.7 1.1 0.9 0.7 98.7 IE2 11404870 337.40 250 487 380 to 480 +10%
0.0 0.7 0.9 0.9 0.9 0.7 1.2 1.0 0.8 98.7 IE2 11405070 351.26 315 507 380 to 480 +10%
0.6 0.8 0.3 0.4 0.8 0.5 0.8 98.0 IE2 12406080 421.23 315 608 380 to 480 +10%
0.5 0.8 0.4 0.5 0.9 0.5 0.9 98.0 IE2 12406600 457.26 355 660 380 to 480 +10%
0.5 0.8 0.4 0.5 0.9 0.5 0.9 98.0 IE2 12407550 523.08 400 755 380 to 480 +10%
0.4 0.8 0.4 0.4 0.8 0.5 0.9 98.0 IE2 12408650 599.29 500 865 380 to 480 +10%
0.6 0.5 0.8 1.7 0.7 1.2 1.7 1.1 2.3 97.8 IE2 05500039 3.88 2.2 3.9 500 to 575 +10%
0.4 0.6 0.7 1.2 0.5 0.8 1.4 0.9 1.7 97.8 IE2 05500061 6.08 4 6.1 500 to 575 +10%
0.2 0.6 0.7 1.2 0.5 0.8 1.4 0.9 1.7 97.8 IE2 05500100 9.96 5.5 10 500 to 575 +10%
0.2 0.6 0.7 1.2 0.5 0.9 1.4 0.9 1.7 97.8 IE2 06500120 11.95 7.5 12 500 to 575 +10%
0.2 0.6 0.7 1.2 0.5 0.8 1.4 0.9 1.7 97.8 IE2 06500170 16.93 11 17 500 to 575 +10%
0.1 0.5 0.7 1.1 0.5 0.8 1.3 0.8 1.6 97.8 IE2 06500220 21.91 15 22 500 to 575 +10%
0.1 0.5 0.7 1.1 0.5 0.8 1.3 0.8 1.6 97.8 IE2 06500270 26.89 18.5 27 500 to 575 +10%
0.1 0.6 0.8 1.3 0.5 0.9 1.5 1.0 1.8 97.8 IE2 06500340 33.86 22 34 500 to 575 +10%
0.1 0.5 0.8 1.3 0.6 0.9 1.7 1.0 1.5 98.1 IE2 06500430 42.82 30 43 500 to 575 +10%
0.1 0.6 0.7 1.3 0.5 0.9 1.5 0.9 1.8 97.8 IE2 07500530 52.78 45 53 500 to 575 +10%
0.1 0.4 0.6 1.0 0.4 0.7 1.1 0.7 1.4 97.8 IE2 07500730 72.70 55 73 500 to 575 +10%
0.1 0.6 0.8 1.3 0.6 0.9 1.5 1.0 1.9 97.8 IE2 08500860 85.65 75 86 500 to 575 +10%
0.0 0.7 0.9 1.4 0.6 1.0 1.7 1.1 2.0 97.8 IE2 08501080 107.56 90 108 500 to 575 +10%
0.0 0.5 0.6 1.1 0.4 0.7 1.2 0.8 1.5 97.8 IE2 09501250 124.49 110 125 500 to 575 +10%
0.0 0.4 0.7 1.0 0.5 0.7 1.4 0.8 1.2 98.1 IE2 09501500 149.39 110 150 500 to 575 +10%
0.0 0.4 0.5 0.8 0.4 0.6 1.1 0.7 1.0 98.1 IE2 10502000 199.19 130 200 500 to 575 +10%
0.0 0.4 0.6 1.0 0.4 0.6 1.3 0.8 1.1 98.1 IE2 11502480 246.99 175 248 500 to 575 +10%
0.0 0.5 0.7 1.1 0.5 0.7 1.4 0.9 1.2 98.1 IE2 11502880 286.83 225 288 500 to 575 +10%
0.0 0.5 0.7 1.1 0.5 0.7 1.5 0.9 1.3 98.1 IE2 11503150 313.72 250 315 500 to 575 +10%

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 10
Table 1-4 Powerdrive F300, Pump F600, HVAC H300 continued
Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated
(% of Apparent Output Power) Rated Supply
Efficiency Efficiency Model Output Motor Output
Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current
(V)
[0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
0.2 0.5 0.6 1.1 0.4 0.7 1.2 0.8 1.5 97.8 IE2 07600230 27.49 18.5 23 500 to 690 +10%
0.1 0.5 0.6 1.0 0.4 0.7 1.2 0.7 1.4 97.8 IE2 07600300 35.85 22 30 500 to 690 +10%
0.1 0.4 0.6 1.0 0.4 0.7 1.1 0.7 1.4 97.8 IE2 07600360 43.02 30 36 500 to 690 +10%
0.1 0.5 0.6 1.1 0.4 0.7 1.2 0.8 1.5 97.8 IE2 07600460 54.98 37 46 500 to 690 +10%
0.1 0.5 0.6 1.1 0.4 0.7 1.2 0.8 1.5 97.8 IE2 07600520 62.15 45 52 500 to 690 +10%
0.1 0.4 0.5 0.8 0.3 0.6 1.0 0.6 1.2 97.8 IE2 07600730 87.24 55 73 500 to 690 +10%
0.0 0.5 0.6 1.1 0.5 0.8 1.3 0.8 1.5 97.8 IE2 08600860 102.78 75 86 500 to 690 +10%
0.0 0.5 0.7 1.2 0.5 0.8 1.4 0.9 1.7 97.8 IE2 08601080 129.07 90 108 500 to 690 +10%
0.0 0.4 0.5 0.8 0.4 0.6 1.1 0.7 0.9 98.1 IE2 09601250 149.39 110 125 500 to 690 +10%
0.0 0.4 0.5 0.8 0.4 0.6 1.1 0.7 1.0 98.1 IE2 09601550 185.24 132 155 500 to 690 +10%
0.0 0.4 0.6 0.9 0.4 0.6 1.2 0.7 1.0 98.1 IE2 10601720 205.56 160 172 500 to 690 +10%
0.0 0.4 0.6 0.9 0.4 0.6 1.2 0.7 1.0 98.1 IE2 10601970 235.44 185 197 500 to 690 +10%
0.0 0.4 0.6 1.0 0.4 0.7 1.3 0.8 1.1 98.1 IE2 11602250 268.90 200 225 500 to 690 +10%
0.0 0.4 0.6 0.9 0.4 0.6 1.2 0.8 1.1 98.1 IE2 11602750 328.66 250 275 500 to 690 +10%
0.0 0.4 0.6 0.9 0.4 0.6 1.3 0.8 1.1 98.1 IE2 11603050 364.51 315 305 500 to 690 +10%

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 11
Table 1-5 Commander S100
Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated
(% of Apparent Output Power) Rated Supply
Efficiency Efficiency Model Output Motor Output
Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current
(V)
[0/0] [24/25] [24/50] [24/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
0.74 1.89 1.81 2.15 1.94 2.07 2.52 1.87 2.38 96.1 IE2 S100-01113 0.42 0.18 1.2 100 to 120 +10 % (1Փ)
0.64 1.74 1.72 2.19 1.88 2.02 2.72 1.75 2.53 96.4 IE2 S100-01123 0.49 0.25 1.4 100 to 120 +10 % (1Փ)
0.52 1.27 1.42 1.91 1.41 1.65 2.41 1.49 2.33 96.2 IE2 S100-01133 0.76 0.37 2.2 100 to 120 +10 % (1Փ)
0.36 1.08 1.34 1.93 1.33 1.50 2.30 1.34 2.23 96.4 IE2 S100-03113 1.11 0.55 3.2 100 to 120 +10 % (1Փ)
0.23 1.29 1.41 1.98 1.42 1.71 2.65 1.72 2.80 95.8 IE2 S100-03123 1.46 0.75 4.2 100 to 120 +10 % (1Փ)
0.15 0.83 1.07 1.64 0.96 1.39 2.51 1.27 2.62 95.8 IE2 S100-03133 2.08 1.10 6 100 to 120 +10 % (1Փ)
0.87 1.78 1.82 2.11 1.88 2.00 2.41 2.05 2.54 96.4 IE2 S100-01S13 0.49 0.18 1.4 200 to 240 +10% (1Փ)
0.87 1.79 1.74 1.96 1.82 1.89 2.22 1.97 2.32 96.4 IE2 S100-01213 0.49 0.18 1.4 200 to 240 +10% (3Փ)
0.88 1.95 1.90 2.17 1.95 2.08 2.52 2.10 2.57 96.2 IE2 S100-02S11 0.42 0.18 1.2 200 to 240 +10% (1Փ)
0.76 1.58 1.67 2.06 1.65 1.81 2.41 1.90 2.50 96.7 IE2 S100-01S23 0.55 0.25 1.6 200 to 240 +10% (1Փ)
0.75 1.72 1.81 1.55 1.80 1.57 1.84 1.82 2.16 96.7 IE2 S100-01223 0.55 0.25 1.6 200 to 240 +10% (3Փ)
0.76 1.83 1.79 2.20 1.89 2.05 2.95 1.97 2.66 96.6 IE2 S100-02S21 0.49 0.25 1.4 200 to 240 +10% (1Փ)
0.50 1.25 1.38 1.80 1.36 1.54 2.14 1.56 2.21 96.5 IE2 S100-01S33 0.83 0.37 2.4 200 to 240 +10% (1Փ)
0.50 1.27 1.14 1.40 1.21 1.29 1.69 1.50 1.97 97.0 IE2 S100-01233 0.83 0.37 2.4 200 to 240 +10% (3Փ)
0.48 1.25 1.39 1.87 1.92 1.67 2.59 1.60 2.81 95.8 IE2 S100-02S31 0.76 0.37 2.2 200 to 240 +10% (1Փ)
0.34 1.04 1.17 1.70 1.20 1.32 2.09 1.59 2.19 96.8 IE2 S100-01S43 1.21 0.55 3.5 200 to 240 +10% (1Փ)
0.35 1.03 1.22 1.66 1.26 1.54 2.07 1.58 2.04 97.2 IE2 S100-01243 1.21 0.55 3.5 200 to 240 +10% (3Փ)
0.41 1.16 1.28 1.73 1.29 1.52 2.14 1.68 2.39 96.7 IE2 S100-02S41 1.11 0.55 3.2 200 to 240 +10% (1Փ)
0.26 0.97 1.05 1.52 1.07 1.22 1.86 1.40 2.13 96.9 IE2 S100-01S53 1.59 0.75 4.6 200 to 240 +10% (1Փ)
0.27 1.06 1.22 1.70 1.14 1.36 2.00 1.26 1.87 97.0 IE2 S100-01253 1.59 0.75 4.6 200 to 240 +10% (3Փ)
0.32 1.06 1.17 1.61 1.19 1.40 2.10 1.53 2.37 96.8 IE2 S100-02S51 1.46 0.75 4.2 200 to 240 +10% (1Փ)
0.23 0.79 0.90 1.34 0.89 1.05 1.68 1.13 1.88 97.0 IE2 200 to 240 +10% (1Փ)
IE2
S100-01D63 2.29 1.10 6.6
0.25 0.79 0.90 1.32 0.88 1.03 1.53 1.07 1.63 97.4 200 to 240 +10% (3Փ)
0.16 1.60 1.28 1.62 1.42 1.56 2.16 1.28 2.07 97.1 IE2 S100-02S61 2.08 1.10 6 200 to 240 +10% (1Փ)
0.16 0.93 1.10 1.64 1.06 1.29 2.10 1.28 2.21 96.7 IE2 200 to 240 +10% (1Փ)
S100-01D73 2.60 1.50 7.5
0.15 0.92 1.08 1.57 1.04 1.23 1.86 1.17 1.87 97.3 IE2 200 to 240 +10% (3Փ)
0.19 1.14 1.22 1.79 1.28 1.46 2.33 1.61 2.66 96.8 IE2 S100-02S71 2.36 1.50 6.8 200 to 240 +10% (1Փ)
0.08 1.20 1.27 1.88 1.36 1.60 2.51 1.47 2.56 96.4 IE2 200 to 240 +10% (1Փ)
S100-03D13 3.67 2.20 10.6
0.11 1.18 0.95 1.38 1.13 1.15 1.71 1.37 2.09 97.0 IE2 200 to 240 +10% (3Փ)

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 12
Table 1-5 Commander S100 continued

Power Loss at Operating Point [% Speed / % Torque] Apparent Indicated Rated


(% of Apparent Output Power) Efficiency Efficiency Model Output Motor Output Rated Supply Voltage
Standby 1 2 3 4 5 6 7 8 (%) Level Identifier Power Power Current (V)
[0/0] [24/25] [24/50] [24/100] [50/25] [50/50] [50/100] [90/50] [90/100] (kVA) (kW) (A)
0.83 1.43 1.63 1.70 1.47 1.57 2.36 1.79 2.19 96.9 IE2 S100-02413 0.83 0.37 1.2 380 to 480 +10% (3Փ)
0.89 1.50 1.53 1.75 1.58 1.66 1.96 1.75 2.08 97.0 IE2 S100-02423 1.18 0.55 1.7 380 to 480 +10% (3Փ)
0.45 1.22 1.23 1.37 1.18 1.31 1.36 1.29 1.76 97.3 IE2 S100-02433 1.52 0.75 2.2 380 to 480 +10% (3Փ)
0.31 0.79 0.93 1.15 0.83 0.97 1.36 1.04 1.55 97.6 IE2 S100-02443 2.22 1.10 3.2 380 to 480 +10% (3Փ)
0.25 0.88 1.07 1.31 0.93 1.17 1.60 1.25 1.77 97.6 IE2 S100-02453 2.56 1.50 3.7 380 to 480 +10% (3Փ)
0.18 1.73 1.68 1.84 1.66 1.70 2.10 1.92 2.43 96.9 IE2 S100-02463 3.67 2.20 5.3 380 to 480 +10% (3Փ)
0.13 0.54 0.64 1.09 0.58 0.81 1.33 0.97 1.70 97.6 IE2 S100-03413 4.99 3.00 7.2 380 to 480 +10% (3Փ)
0.11 0.68 0.84 1.41 0.79 1.02 1.73 1.18 1.95 97.6 IE2 S100-03423 6.10 4.00 8.8 380 to 480 +10% (3Փ)

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 13
3. Power Losses

Table 2-1 Digitax HD M75x


Maximum Power Loss at Operating Point [% Speed / % Torque]
Nominal Rated
Model Continuous (W)
Power Voltage
Number Output Current Standby 1 2 3 4 5 6 7 8
(kW) (V)
(A) [0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100]
01200022 0.37 2.2 200 2.2 5.7 7.3 11.2 4 8.4 14.5 9.4 15.7
01200040 0.75 4 200 2.2 10.3 13.3 20.4 7.3 15.4 26.4 17.2 28.5
01200065 1.1 6.5 200 2.2 15.9 20.5 31.5 11.4 23.8 40.9 26.7 44.2
02200090 2.2 9 200 3.2 13.2 16.6 37.4 12.5 23.8 39.9 19 52.2
02200120 2.2 12 200 4.3 17.6 22.2 49.9 16.7 31.8 53.2 25.3 69.6
03200160 4 16 200 2.2 30.3 39.3 72.8 35.7 59.1 68.0 68.7 118.9
01400015 0.37 1.5 400 6.1 6.7 6.5 12.9 3.8 6.8 12.6 13.9 17.7
01400030 0.75 3 400 6.1 13.5 12.9 25.8 7.5 13.5 25.3 27.9 35.4
01400042 1.5 4.2 400 6.1 15.7 15.1 30.1 8.8 15.8 29.5 32.5 41.3
02400060 2.2 6 400 5.0 13.9 12.4 34.6 12.6 26.8 36.5 29.4 79.1
02400080 3 8 400 5.0 18.5 16.5 46.1 16.8 35.8 48.7 39.3 105.4
02400105 4 10.5 400 5.0 24.3 21.7 60.5 22.0 46.9 63.9 51.5 138.3
03400135 5.5 13.5 400 5.0 24.8 22.1 61.6 22.4 47.8 65.1 52.5 140.9
03400160 5.5 16 400 5.0 37.1 33 92.2 33.5 71.5 97.4 78.5 210.8

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 14
Table 2-2 Commander C200/C300/M400/HS30 (Frame 1 – 4)
Maximum Power Loss at Operating Point [% Speed / % Torque]
Nominal Rated
Model Continuous (W)
Power Voltage
Number Output Current Standby 1 2 3 4 5 6 7 8
(kW) (V)
(A) [0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100]
01200017 0.25 1.7 200 5.6 9.7 11.5 16.4 11.0 12.5 19.8 14.1 22.0
01200024 0.37 2.4 200 5.6 13.7 16.3 23.1 15.6 17.6 28.0 19.9 31.0
01200033 0.55 3.3 200 5.6 18.8 22.3 31.8 21.4 24.2 38.5 27.3 42.6
01200042 0.75 4.2 200 5.6 19.9 23.7 33.7 22.7 25.7 40.8 29.0 45.2
02200024 0.37 2.4 200 10.4 7.7 9.8 16.3 7.2 8.9 16.0 11.9 21.1
02200033 0.55 3.3 200 10.4 10.6 13.5 22.4 9.9 12.2 22.0 16.4 29.0
02200042 0.75 4.2 200 10.4 13.5 17.2 28.5 12.6 15.5 28.0 20.9 36.9
02200056 1.1 5.6 200 10.4 18 22.9 38.0 16.8 20.7 37.3 27.8 49.1
02200075 1.5 7.5 200 10.4 20 25.3 42.1 18.7 22.9 41.3 30.8 54.4
03200100 2.2 10 200 9.0 21.1 41.8 50.1 31.5 36.8 45.9 44.4 73.9
04200133 3 13.3 200 10.7 28.9 35.5 79.6 32.6 40.6 74.5 47.1 104.9
04200176 4 17.6 200 10.7 31.6 38.9 87.1 35.6 44.4 81.5 51.5 114.8
02400013 0.37 1.3 400 8.5 9.3 9.7 12.7 8.4 10.3 14.3 12.7 19.4
02400018 0.55 1.8 400 8.5 12.9 13.4 17.6 11.6 14.2 19.8 17.6 26.8
02400023 0.75 2.3 400 8.5 16.5 17.2 22.5 14.9 18.1 25.2 22.5 34.2
02400032 1.1 3.2 400 8.5 23 23.9 31.4 20.7 25.2 35.1 31.3 47.6
02400041 1.5 4.1 400 8.5 25.9 26.9 35.3 23.3 28.4 39.5 35.2 53.6
03400056 2.2 5.6 400 10.2 15.2 22.5 43.2 5.1 20.5 43.0 16.7 47.1
03400073 3 7.3 400 10.2 19.8 29.3 56.3 6.6 26.7 56.1 21.8 61.4
03400094 4 9.4 400 10.2 24 35.5 68.2 8.1 32.4 68.0 26.4 74.4
04400135 5.5 13.5 400 9.8 37.9 56.6 94.8 53.2 57.5 106.9 98.2 148.9
04400170 7.5 17 400 9.8 42.6 63.7 106.7 59.9 64.7 120.3 110.6 167.7

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 15
Table 2-3 Unidrive E300/HS7x/M600/M70x/M88x, Commander C200/C300 (Frame 5 – 9)
Maximum Power Loss at Operating Point [% Speed / % Torque]
Nominal Rated
Model Continuous (W)
Power Voltage
Number Output Current Standby 1 2 3 4 5 6 7 8
(kW) (V)
(A) [0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100]
03200050 0.75 5 200 16.5 16.8 25.3 38.1 13.9 24.8 37.0 24.3 39
03200066 1.1 6.6 200 16.5 22.1 33.3 50.3 18.3 32.8 48.8 32.0 51.5
03200080 1.5 8 200 16.5 26.8 40.4 61.0 22.2 39.7 59.1 38.8 62.4
03200106 2.2 10.6 200 16.5 29.2 43.9 66.4 24.1 43.2 64.3 42.2 67.9
04200137 3 13.7 200 18.7 43.9 56.9 130.6 52.7 63.8 119.8 55.8 132.1
04200185 4 18.5 200 18.7 46.7 60.4 138.7 56.0 67.7 127.2 59.3 140.3
05200250 5.5 25 200 22.5 75.3 106.7 176.1 78.6 139.4 240.9 153.7 382.7
06200330 7.5 33 200 20.1 72.7 113.4 175.6 89.8 106.5 179.4 140.2 285.7
06200440 11 44 200 20.1 77.2 120.3 186.2 95.2 113.0 190.3 148.7 303
07200610 15 61 200 20.1 107.0 166.8 258.1 132.0 156.7 263.8 206.2 420.1
07200750 18.5 75 200 20.1 131.5 205.1 317.4 162.3 192.6 324.4 253.5 516.5
07200830 22 83 200 20.1 145.5 226.9 351.2 179.6 213.2 359.0 280.5 571.6
08201160 30 116 200 20.1 203.4 317.2 490.9 251 297.9 501.7 392.0 798.8
08201320 37 132 200 20.1 231.5 360.9 558.6 285.6 339.0 570.9 446.1 909
09201760 45 176 200 20.1 308.6 481.2 744.8 380.8 452.0 761.2 594.8 1212
09202190 55 219 200 20.1 384 598.8 926.8 473.8 562.4 947.2 740.1 1508
10202830 75 283 200 20.1 496.2 773.7 1198 612.3 726.8 1224 956.4 1949
10203000 90 300 200 20.1 526.0 820.2 1270 649.1 770.5 1298 1014 2066
03400025 0.75 2.5 400 18.9 13.8 19.5 25.3 9.1 18.44 28.1 20.0 34.2
03400031 1.1 3.1 400 18.9 17.2 24.1 31.3 11.3 22.9 34.8 24.8 42.5
03400045 1.5 4.5 400 18.9 24.9 35.0 45.5 16.3 33.2 50.5 36.0 61.6
03400062 2.2 6.2 400 18.9 34.9 49.0 63.7 22.9 46.5 70.7 50.4 86.3
03400078 3 7.8 400 18.9 43.2 60.7 78.9 28.3 57.5 87.5 62.4 106.9
03400100 4 10 400 18.9 55.3 77.8 101.1 36.3 73.8 112.2 80.0 137
04400150 5.5 15 400 18.7 38.6 62.1 136.7 55.9 95.5 131.8 90.9 185.6
04400172 7.5 17.2 400 18.7 51.0 82.0 180.4 73.8 126.0 174.0 120.0 245
05400220 9 22 400 22.5 57.4 81.4 134.3 59.9 106.3 183.7 117.23 291.9
05400270 11 27 400 22.5 75.3 106.7 175.9 78.5 139.3 240.7 153.5 382.4
05400300 15 30 400 22.5 78.3 111.0 183.1 81.7 145.0 250.5 159.8 398
06400350 15 35 400 26.2 89.5 127.7 266.3 94.4 184.5 352.6 145.0 518.6
06400420 18.5 42 400 26.2 155.7 222 463.1 164.2 320.8 613.0 252.2 901.7
06400470 22 47 400 26.2 174.2 248.4 518.2 183.7 359.0 686.0 282.2 1009
07400660 30 66 400 51.1 128.3 226.5 275.8 119.8 232.5 553.2 358.2 412.4
07400770 37 77 400 51.1 149.7 264.3 321.7 139.8 271.2 645.4 417.9 481.1
07401000 45 100 400 51.1 194.4 343.2 417.8 181.5 352.2 838.2 542.7 624.8
Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators
Issue Number 4 16
Table 2-3 Unidrive E300/HS7x/M600/M70x/M88x, Commander C200/C300 (Frame 5 – 9) continued
Maximum Power Loss at Operating Point [% Speed / % Torque]
Nominal Rated
Model Continuous (W)
Power Voltage
Number Output Current Standby 1 2 3 4 5 6 7 8
(kW) (V)
(A) [0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100]
08401340 55 134 400 51.1 260.5 460 559.9 243.2 472 1123 727.2 837.3
08401570 75 157 400 51.1 305.2 538.9 656 285 553 1316 852 981
09402000 90 200 400 53 1067 1481 2592 1185 1556 2815 1629 2592
09402240 110 224 400 53 1195 1659 2904 1327 1742 3153 1825 2903
10402700 132 270 400 53 946 1314 2299 1051 1380 2496 1445 2299
10403200 160 320 400 53 1440 2000 3500 1600 2100 3800 2200 3500
11403770 185 377 400 81 2124 2432 2432 2432 2092 3324 2757 2270
11404170 200 417 400 81 2350 2690 2690 2690 2314 3677 3049 2511
11404640 250 464 400 81 2620 3000 3000 3000 2580 4100 3400 2800
12404800 250 480 400 2400 3218 1443 1776 3385 1942 3551
12405660 315 566 400 2400 3795 1701 2093 3991 2290 4187
12406600 355 660 400 2400 4425 1984 2442 4654 2671 4883
12407200 400 720 400 2400 4827 2164 2664 5077 2913 5327
05500030 1.5 3 575 22.5 18.9 30.3 66.7 27.3 46.6 64.4 44.4 90.6
05500040 2.2 4 575 22.5 33.7 43.9 74.6 31.3 51 86.4 55.5 104.4
05500069 4 6.9 575 22.5 54.9 71.7 121.7 51 83.1 141 90.5 170.3
06500100 5.5 10 575 26.2 67.4 87.9 149.2 62.6 101.9 172.8 111 208.9
06500150 7.5 15 575 26.2 95.1 124.1 210.7 88.3 143.9 244.1 156.8 295
06500190 11 19 575 26.2 112.6 146.8 249.4 104.6 170.3 288.9 185.6 349.1
06500230 15 23 575 26.2 135.8 177.1 300.8 126.1 205.5 348.5 223.8 421.1
06500290 18.5 29 575 26.2 196.6 256.5 435.5 182.6 297.5 504.5 324.1 609.7
06500350 22 35 575 26.2 233.6 351.9 547.4 246.7 366.4 738.2 448.8 624.8
07500440 30 44 575 51.1 299.2 390.2 662.7 277.8 452.6 767.6 493.1 927.6
07500550 37 55 575 51.1 323.7 422.2 716.9 300.6 489.7 830.4 533.5 1004
08500630 45 63 575 51.1 511.8 667.5 1134 475.2 774.2 1313 843.5 1587
08500860 55 86 575 51.1 702.5 916.2 1556 652.4 1063 1802 1158 2178
09501040 75 104 575 53 590.5 770.1 1308 548.4 893.3 1515 973.2 1831
09501310 90 131 575 53 652.8 983.3 1530 689.3 1024 2063 1254 1746
10501520 110 152 575 53 718.8 1083 1684 759 1127 2271 1381 1923
10501900 132 190 575 53 828.1 1247 1940 874.4 1299 2617 1591 2215
11502000 150 200 575 81 1015 1528 2377 1071 1591 3206 1949 2713
11502540 185 254 575 81 1300 1958 3045 1372 2038 4106 2497 3476
11502850 225 285 575 81 1478 2226 3462 1560 2318 4669 2839 3952

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 17
Table 2-3 Unidrive E300/HS7x/M600/M70x/M88x, Commander C200/C300 (Frame 5 – 9) continued
Maximum Power Loss at Operating Point [% Speed / % Torque]
Nominal Rated
Model Continuous (W)
Power Voltage
Number Output Current Standby 1 2 3 4 5 6 7 8
(kW) (V)
(A) [0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100]
07600190 15 19 690 51.1 131.2 171.1 290.6 121.9 198.5 336.7 216.3 406.9
07600240 18.5 24 690 51.1 161.8 211.1 358.5 150.3 244.8 415.2 266.7 501.8
07600290 22 29 690 51.1 192.5 251 426.3 178.7 291.1 493.8 317.2 596.7
07600380 30 38 690 51.1 262.4 342.3 581.3 243.7 397 673.3 432.6 813.7
07600440 37 44 690 51.1 301 392.6 666.7 279.5 455.4 772.3 496.1 933.3
07600540 45 54 690 51.1 326.7 426.1 723.7 303.4 494.3 838.3 538.5 1013
08600630 55 63 690 51.1 510 665.2 1130 473.6 771.5 1309 840.6 1581
08600860 75 86 690 51.1 702 915.6 1555 651.9 1062 1801 1157 2178
09601040 90 104 690 53 526.4 792.8 1233 555.8 825.6 1663 1011 1408
09601310 110 131 690 53 661.3 996.1 1550 698.3 1037 2090 1271 1769
10601500 132 150 690 53 767.7 1156 1799 810.6 1204 2426 1475 2053
10601780 160 178 690 53 862.6 1299 2021 910.8 1353 2726 1657 2307
11602100 185 210 690 81 1136 1712 2663 1200 1782 3591 2183 3039
11602380 200 238 690 81 1294 1949 3032 1366 2029 4088 2486 3461
11602630 250 263 690 81 1446 2178 3388 1527 2268 4568 2778 3867

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 18
Table 2-4 Powerdrive F300, Pump F600, HVAC H300
Maximum Power Loss at Operating Point [% Speed / % Torque]
Nominal Rated
Model Continuous (W)
Power Voltage
Number Output Current Standby 1 2 3 4 5 6 7 8
(kW) (V)
(A) [0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100]
03200066 1.1 6.6 200 16.5 16.8 25.3 38.1 13.9 24.8 37 24.3 39
03200080 1.5 8 200 16.5 22.1 33.3 50.3 18.3 32.8 48.8 32 51.5
03200110 2.2 11 200 16.5 26.8 40.4 61 22.2 39.7 59.1 38.8 62.4
03200127 3 12.7 200 16.5 29.2 43.9 66.4 24.1 43.2 64.3 42.2 67.9
04200180 4 18 200 18.7 43.9 56.9 130.6 52.7 63.8 119.8 55.8 132.1
04200250 5.5 25 200 18.7 46.7 60.4 138.7 56 67.7 127.2 59.3 140.3
05200300 7.5 30 200 22.5 75.3 106.7 176.1 78.6 139.4 240.9 153.7 382.7
06200500 11 50 200 20.1 72.7 113.4 175.6 89.8 106.5 179.4 140.2 285.7
06200580 15 58 200 20.1 77.2 120.3 186.2 95.2 113 190.3 148.7 303
07200750 18.5 75 200 20.1 107 166.8 258.1 132 156.7 263.8 206.2 420.1
07200940 22 94 200 20.1 131.5 205.1 317.4 162.3 192.6 324.4 253.5 516.5
07201170 30 117 200 20.1 145.5 226.9 351.2 179.6 213.2 359 280.5 571.6
08201490 37 149 200 20.1 203.4 317.2 490.9 251 297.9 501.7 392 798.8
08201800 45 180 200 20.1 231.5 360.9 558.6 285.6 339 570.9 446.1 909
09202160 55 216 200 20.1 308.6 481.2 744.8 380.8 452 761.2 594.8 1212
09202660 75 266 200 20.1 384 598.8 926.8 473.8 562.4 947.2 740.1 1508
10203250 90 325 200 20.1 496.2 773.7 1198 612.3 726.8 1224 956.4 1949
10203600 110 360 200 20.1 526 820.2 1270 649.1 770.5 1298 1014 2066
03400034 1.1 3.4 400 18.9 13.8 19.5 25.3 9.1 18.44 28.1 20 34.2
03400045 1.5 4.5 400 18.9 17.2 24.1 31.3 11.25 22.9 34.8 24.8 42.5
03400062 2.2 6.2 400 18.9 24.9 35 45.5 16.3 33.2 50.5 36 61.6
03400077 3 7.7 400 18.9 34.9 49 63.7 22.9 46.5 70.7 50.4 86.3
03400104 4 10.4 400 18.9 43.2 60.7 78.9 28.3 57.5 87.5 62.4 106.9
03400123 5.5 12.3 400 18.9 55.3 77.8 101.1 36.3 73.8 112.2 80 137
04400185 7.5 18.5 400 18.7 38.6 62.1 136.7 55.9 95.5 131.8 90.9 185.6
04400240 11 24 400 18.7 51 82 180.4 73.8 126 174 120 245
05400300 15 30 400 22.5 78.3 111 183.1 81.7 145 250.5 159.8 398
06400380 18.5 38 400 26.2 89.5 127.7 266.3 94.4 184.5 352.6 145 518.6
06400480 22 48 400 26.2 155.7 222 463.1 164.2 320.8 613 252.2 901.7
06400630 30 63 400 26.2 174.2 248.4 518.2 183.7 359 686 282.2 1009

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 19
Table 2-4 Powerdrive F300, Pump F600, HVAC H300 continued
Maximum Power Loss at Operating Point [% Speed / % Torque]
Nominal Rated
Model Continuous (W)
Power Voltage
Number Output Current Standby 1 2 3 4 5 6 7 8
(kW) (V)
(A) [0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100]
07400790 37 79 400 51.1 128.3 226.5 275.8 119.8 232.5 553.2 358.2 412.4
07400940 45 94 400 51.1 149.7 264.3 321.7 139.8 271.2 645.4 417.9 481.1
07401120 55 112 400 51.1 194.4 343.2 417.8 181.5 352.2 838.2 542.7 624.8
08401550 75 155 400 51.1 260.5 460 559.9 243.2 472 1123 727.2 837.3
08401840 90 184 400 51.1 305.2 538.9 656 285 553 1316 852 981
09402210 110 221 400 53 1067 1481 2592 1185 1556 2815 1629 2592
09402660 132 266 400 53 1195 1659 2904 1327 1742 3153 1825 2903
10403200 160 320 400 53 946 1314 2299 1051 1380 2496 1445 2299
10403610 200 361 400 53 1440 2000 3500 1600 2100 3800 2200 3500
11404370 225 437 400 81 2124 2432 2432 2432 2092 3324 2757 2270
11404870 250 487 400 81 2350 2690 2690 2690 2314 3677 3049 2511
11405070 315 507 400 81 2620 3000 3000 3000 2580 4100 3400 2800
12406080 315 608 400 2400 3218 1443 1776 3385 1942 3551
12406600 355 660 400 2400 3795 1701 2093 3991 2290 4187
12407550 400 755 400 2400 4425 1984 2442 4654 2671 4883
12408650 500 865 400 2400 4827 2164 2664 5077 2913 5327
05500039 2.2 3.9 575 22.5 18.9 30.3 66.7 27.3 46.6 64.4 44.4 90.6
05500061 4 6.1 575 22.5 33.7 43.9 74.6 31.3 51 86.4 55.5 104.4
05500100 5.5 10 575 22.5 54.9 71.7 121.7 51 83.1 141 90.5 170.3
06500120 7.5 12 575 26.2 67.4 87.9 149.2 62.6 101.9 172.8 111 208.9
06500170 11 17 575 26.2 95.1 124.1 210.7 88.3 143.9 244.1 156.8 295
06500220 15 22 575 26.2 112.6 146.8 249.4 104.6 170.3 288.9 185.6 349.1
06500270 18.5 27 575 26.2 135.8 177.1 300.8 126.1 205.5 348.5 223.8 421.1
06500340 22 34 575 26.2 196.6 256.5 435.5 182.6 297.5 504.5 324.1 609.7
06500430 30 43 575 26.2 233.6 351.9 547.4 246.7 366.4 738.2 448.8 624.8
07500530 45 53 575 51.1 299.2 390.2 662.7 277.8 452.6 767.6 493.1 927.6
07500730 55 73 575 51.1 323.7 422.2 716.9 300.6 489.7 830.4 533.5 1004
08500860 75 86 575 51.1 511.8 667.5 1134 475.2 774.2 1313 843.5 1587
08501080 90 108 575 51.1 702.5 916.2 1556 652.4 1063 1802 1158 2178
09501250 110 125 575 53 590.5 770.1 1308 548.4 893.3 1515 973.2 1831
09501500 110 150 575 53 652.8 983.3 1530 689.3 1024 2063 1254 1746
10502000 130 200 575 53 718.8 1083 1684 759 1127 2271 1381 1923
11502480 175 248 575 81 1015 1528 2377 1071 1591 3206 1949 2713
11502880 225 288 575 81 1300 1958 3045 1372 2038 4106 2497 3476
11503150 250 315 575 81 1478 2226 3462 1560 2318 4669 2839 3952
Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators
Issue Number 4 20
Table 2-4 Powerdrive F300, Pump F600, HVAC H300 continued
Maximum Power Loss at Operating Point [% Speed / % Torque]
Nominal Rated
Model Continuous (W)
Power Voltage
Number Output Current Standby 1 2 3 4 5 6 7 8
(kW) (V)
(A) [0/0] [25/25] [25/50] [25/100] [50/25] [50/50] [50/100] [90/50] [90/100]
07600230 18.5 23 690 51.1 131.2 171.1 290.6 121.9 198.5 336.7 216.3 406.9
07600300 22 30 690 51.1 161.8 211.1 358.5 150.3 244.8 415.2 266.7 501.8
07600360 30 36 690 51.1 192.5 251 426.3 178.7 291.1 493.8 317.2 596.7
07600460 37 46 690 51.1 262.4 342.3 581.3 243.7 397 673.3 432.6 813.7
07600520 45 52 690 51.1 301 392.6 666.7 279.5 455.4 772.3 496.1 933.3
07600730 55 73 690 51.1 326.7 426.1 723.7 303.4 494.3 838.3 538.5 1013
08600860 75 86 690 51.1 510 665.2 1130 473.6 771.5 1309 840.6 1581
08601080 90 108 690 51.1 702 915.6 1555 651.9 1062 1801 1157 2178
09601250 110 125 690 53 526.4 792.8 1233 555.8 825.6 1663 1011 1408
09601550 132 155 690 53 661.3 996.1 1550 698.3 1037 2090 1271 1769
10601720 160 172 690 53 767.7 1156 1799 810.6 1204 2426 1475 2053
10601970 185 197 690 53 862.6 1299 2021 910.8 1353 2726 1657 2307
11602250 200 225 690 81 1136 1712 2663 1200 1782 3591 2183 3039
11602750 250 275 690 81 1294 1949 3032 1366 2029 4088 2486 3461
11603050 315 305 690 81 1446 2178 3388 1527 2268 4568 2778 3867

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators


Issue Number 4 21
Table 2-5 Commander S100
Maximum Power Loss at Operating Point [% Speed / % Torque]
Nominal
Model Continuous Rated Voltage (W)
Power
Number Output Current (V) Standby 1 2 3 4 5 6 7 8
(kW)
(A) [0/0] [24/25] [24/50] [24/100] [50/25] [50/50] [50/100] [90/50] [90/100]
S100-01113 0.18 1.2 100 to 120 +10 % (1Փ) 3.1 7.8 7.5 8.9 8.1 8.6 10.5 7.8 9.9
S100-01123 0.25 1.4 100 to 120 +10 % (1Փ) 3.1 8.4 8.4 10.6 9.1 9.8 13.2 8.5 12.3
S100-01133 0.37 2.2 100 to 120 +10 % (1Փ) 4.0 9.7 10.8 14.5 10.7 12.6 18.4 11.3 17.8
S100-03113 0.55 3.2 100 to 120 +10 % (1Փ) 4.0 12.0 14.8 21.4 14.7 16.6 25.5 14.8 24.7
S100-03123 0.75 4.2 100 to 120 +10 % (1Փ) 3.4 18.7 20.6 28.7 20.7 24.8 38.5 25.1 40.8
S100-03133 1.10 6.0 100 to 120 +10 % (1Փ) 3.2 17.2 22.3 34.0 20.0 28.9 52.1 26.3 54.5
S100-01S13 0.18 1.4 200 to 240 +10% (1Փ) 4.2 8.6 8.8 10.2 9.1 9.7 11.7 9.9 12.3
S100-01213 0.18 1.4 200 to 240 +10% (3Փ) 4.2 8.7 8.4 9.5 8.8 9.2 10.8 9.5 11.2
S100-02S11 0.18 1.2 200 to 240 +10% (1Փ) 3.7 8.1 7.9 9.0 8.1 8.7 10.5 8.7 10.7
S100-01S23 0.25 1.6 200 to 240 +10% (1Փ) 4.2 8.8 9.2 11.4 9.1 10.0 13.4 10.6 13.8
S100-01223 0.25 1.6 200 to 240 +10% (3Փ) 4.2 9.5 10.0 8.6 10.0 8.7 10.2 10.1 12.0
S100-02S21 0.25 1.4 200 to 240 +10% (1Փ) 3.7 8.9 8.7 10.7 9.2 10.0 14.3 9.5 12.9
S100-01S33 0.37 2.4 200 to 240 +10% (1Փ) 4.2 10.4 11.4 15.0 11.3 12.8 17.8 13.0 18.4
S100-01233 0.37 2.4 200 to 240 +10% (3Փ) 4.2 10.6 9.5 11.6 10.1 10.7 14.0 12.5 16.3
S100-02S31 0.37 2.2 200 to 240 +10% (1Փ) 3.7 9.5 10.6 14.3 14.7 12.7 19.7 12.2 21.4
S100-01S43 0.55 3.5 200 to 240 +10% (1Փ) 4.1 12.6 14.1 20.6 14.6 16.0 25.3 19.3 26.6
S100-01243 0.55 3.5 200 to 240 +10% (3Փ) 4.2 12.5 14.8 20.2 15.3 18.7 25.1 19.2 24.7
S100-02S41 0.55 3.2 200 to 240 +10% (1Փ) 4.5 12.8 14.2 19.2 14.3 16.8 23.7 18.6 26.5
S100-01S53 0.75 4.6 200 to 240 +10% (1Փ) 4.1 15.5 16.7 24.2 17.1 19.4 29.6 22.3 33.9
S100-01253 0.75 4.6 200 to 240 +10% (3Փ) 4.3 16.9 19.5 27.1 18.2 21.7 31.8 20.0 29.7
S100-02S51 0.75 4.2 200 to 240 +10% (1Փ) 4.7 15.4 17.0 23.5 17.4 20.4 30.6 22.2 34.5
200 to 240 +10% (1Փ) 5.2 18.1 20.7 30.6 20.2 24.0 38.4 25.8 42.9
S100-01D63 1.10 6.6
200 to 240 +10% (3Փ) 5.7 18.0 20.6 30.1 20.0 23.6 35.0 24.4 37.3
S100-02S61 1.10 6 200 to 240 +10% (1Փ) 3.4 33.2 26.5 33.7 29.6 32.4 44.9 26.7 43.1
200 to 240 +10% (1Փ) 4.3 24.1 28.5 42.5 27.6 33.6 54.5 33.2 57.5
S100-01D73 1.50 7.5
200 to 240 +10% (3Փ) 4.0 23.9 28.2 40.7 27.0 31.9 48.4 30.5 48.5
S100-02S71 1.50 6.8 200 to 240 +10% (1Փ) 4.4 27.0 28.7 42.1 30.1 34.3 54.9 37.9 62.7
200 to 240 +10% (1Փ) 3.0 44.0 46.8 68.9 50.0 58.9 92.1 53.8 93.9
S100-03D13 2.20 10.6
200 to 240 +10% (3Փ) 4.0 43.3 35.0 50.7 41.5 42.1 62.7 50.4 76.8
S100-02413 0.37 1.2 380 to 480 +10% (3Փ) 6.9 11.9 13.6 14.1 12.3 13.1 19.6 14.9 18.2
S100-02423 0.55 1.7 380 to 480 +10% (3Փ) 10.5 17.7 18.0 20.6 18.6 19.6 23.1 20.6 24.5
S100-02433 0.75 2.2 380 to 480 +10% (3Փ) 6.8 18.5 18.7 20.9 17.9 20.0 20.7 19.7 26.8
S100-02443 1.10 3.2 380 to 480 +10% (3Փ) 6.8 17.6 20.7 25.6 18.4 21.5 30.3 23.1 34.3
S100-02453 1.50 3.7 380 to 480 +10% (3Փ) 6.5 22.5 27.5 33.7 24.0 30.1 40.9 32.0 45.4
S100-02463 2.20 5.3 380 to 480 +10% (3Փ) 6.5 63.4 61.9 67.4 60.9 62.4 77.1 70.4 89.3
S100-03413 3.00 7.2 380 to 480 +10% (3Փ) 6.6 27.2 32.0 54.1 28.8 40.2 66.3 48.2 84.6
S100-03423 4.00 8.8 380 to 480 +10% (3Փ) 6.4 41.3 51.3 85.8 48.2 62.2 105.3 71.8 118.6

Control Techniques Drives EU 2019/1781 Ecodesign Regulation Energy Efficiency Indicators