SGP122168
SGP122168
CYTEC INDUSTRIES INC., FIVE GARRET MOUNTAIN PLAZA, WOODLAND PARK, NEW JERSEY 07424, USA
For Product and all Non-Emergency Information call 1-800/652-6013. Outside the USA and Canada call 1-973/357-
3193.
EMERGENCY PHONE (24 hours/day) - For emergency only involving spill, leak, fire, exposure or accident call:
Asia Pacific:
Australia - +61-3-9663-2130 or 1800-033-111 (IXOM)
China (PRC) - +86 0532 83889090 (NRCC)
New Guinea - +61-3-9663-2130 or 1800-033-111
New Zealand - +61-3-9663-2130 or 0800-734-607 (IXOM)
India, Japan, Korea, Malaysia, Thailand - +65 3158 1074 (Carechem24 Singapore)
India (Hindi Speaking Only) - +65 3158 1198 or 000800 100 7479 (Carechem24 Singapore)
Canada: +1-905-356-8310 (Cytec Welland, Canada plant)
Europe/Africa/Middle East (Carechem24 UK):
Europe, Middle East, Africa, Israel - +44 (0) 1235 239 670
(Arabic speaking countries) - +44 (0) 1235 239 671
Latin America:
Brazil - 0800 7077 022 (SUATRANS)
Chile - +56-2-2-247-3600 (CITUC QUIMICO)
All Others - +52-376-73 74122 (Cytec Atequiza, Mexico plant)
USA: +1-703-527-3887 or 1-800-424-9300 (CHEMTREC #CCN6083)
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
2. HAZARDS IDENTIFICATION
GHS Classification
Germ Cell Mutagenicity Hazard Category 2
Skin Sensitizer Hazard Category 1B
Aquatic Environment Acute Hazard Category 3
Aquatic Environment Chronic Hazard Category 3
LABEL ELEMENTS
Signal Word
Warning
L - 306 Epoxy Paste Adhesive, Part A SDS: 0056483 Date Prepared: 03/02/2016 Page 2 of 9
Hazard Statements
Suspected of causing genetic defects
May cause an allergic skin reaction
Harmful to aquatic life with long lasting effects
Precautionary Statements
Obtain special instructions before use.
Wear protective gloves/protective clothing/eye protection/face protection.
Avoid breathing dust/fume/gas/mist/vapours/spray.
Contaminated work clothing should not be allowed out of the workplace.
Avoid release to the environment.
IF exposed or concerned: Get medical advice/attention.
IF ON SKIN: Wash with plenty of soap and water.
If skin irritation or rash occurs: Get medical advice/attention.
Specific treatment (see supplemental first aid instructions on this label).
Wash contaminated clothing before reuse.
Store locked up.
Dispose of contents/container in accordance with local and national regulations.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
3. COMPOSITION/INFORMATION ON INGREDIENTS
Substance, Mixture or Article? Mixture
HAZARDOUS INGREDIENTS
The specific chemical identity and/or exact percentage of composition for one or more ingredients has been withheld as a
trade secret.
Additional GHS classification or other information may be included in this section but has not been adopted by OSHA.
See Section 16 for full text of H phrases.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
Eye Contact:
Rinse immediately with plenty of water for at least 15 minutes.
L - 306 Epoxy Paste Adhesive, Part A SDS: 0056483 Date Prepared: 03/02/2016 Page 3 of 9
Skin Contact:
Wash immediately with plenty of water and soap. Remove contaminated clothing and shoes without delay. Obtain
medical attention. Do not reuse contaminated clothing without laundering. Destroy or thoroughly clean shoes before
reuse.
Ingestion:
If swallowed, call a physician immediately. Only induce vomiting at the instruction of a physician. Never give
anything by mouth to an unconscious person.
Inhalation:
Remove to fresh air. If breathing is difficult, give oxygen. Obtain medical advice if there are persistent symptoms.
None known
Not applicable
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing Media:
Use water spray or fog, carbon dioxide or dry chemical.
Protective Equipment:
Firefighters, and others exposed, wear self-contained breathing apparatus. Wear full firefighting protective clothing. See
MSDS Section 8 (Exposure Controls/Personal Protection).
Special Hazards:
None known
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
Special Handling Statements: Provide good ventilation of working area (local exhaust ventilation if necessary).
L - 306 Epoxy Paste Adhesive, Part A SDS: 0056483 Date Prepared: 03/02/2016 Page 4 of 9
STORAGE
Store in accordance with local, state, and federal regulations.
Storage Temperature: Store at 25 °C 77 °F
Reason: Quality.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
Respiratory Protection:
Where exposures are below the established exposure limit, no respiratory protection is required. Where exposures
exceed the established exposure limit, use respiratory protection recommended for the material and level of exposure. A
full facepiece respirator also provides eye and face protection. Cutting, grinding or sanding of parts fabricated after curing
may create respirable dust particles. Respiratory protection appropriate for this dust may be required. Refer to
components listed above for potential hazardous components in the dust.
Eye Protection:
Wear eye/face protection such as chemical splash proof goggles or face shield. Eyewash equipment and safety shower
should be provided in areas of potential exposure.
Skin Protection:
Avoid skin contact. Wear impermeable gloves and suitable protective clothing. Barrier creams may be used in conjunction
with the gloves to provide additional skin protection.
Hand Protection:
Nitrile or fluorinated rubber gloves. Consider the porosity and elasticity data of the glove manufacturer and the specific
conditons in the work place. Consider the porosity and elasticity data of the glove manufacturer and the specific
conditions in the work place. Barrier creams may help to protect the exposed areas of the skin, they should however not
be applied once exposure has occurred.
Additional Advice:
Food, beverages, and tobacco products should not be carried, stored, or consumed where this material is in use. Before
eating, drinking, or smoking, wash face and hands thoroughly with soap and water. It is recommended that a shower be
taken after completion of workshift especially if significant contact has occurred. Work clothing should then be laundered
prior to reuse. Street clothing should be stored separately from work clothing and protective equipment. Work clothing and
shoes should not be taken home.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
Exposure Limit(s)
The below constituents are the only constituents of the product which have a PEL, TLV or other recommended exposure
limit. At this time, the other constituents have no known exposure limits.
ALLERGIC SENSITIZATION
Sensitization skin Sensitizing
Sensitization respiratory No data
GENOTOXICITY
OTHER INFORMATION
The product toxicity information above has been estimated.
o-Cresyl glycidyl ether has an oral LD50 (rat) value of 2500 mg/kg and a dermal LD50 (rabbit) value of 2300 mg/kg. This
material is irritating to eyes and skin. Liquid may cause skin sensitization. Inhalation of vapors may cause CNS
depression and irritation to the nose, throat and respiratory tract.
Silicon Dioxide has acute oral (rat) LD50 values ranging from 3160 mg/kg to >7500 mg/kg. The LC50 (rat) following a 4-
hour inhalation study is >0.25 mg/L (maximum attainable concentration). Chronic and sub-chronic inhalation tests with
laboratory animals produced lung damage and death after the lung clearance mechanisms were overloaded. Amorphous
silica does not cause the lung diseases crystalline silica is known to cause.
California Proposition 65 Warning (applicable in California only) - This product contains (a) chemical(s) known to the State
of California to cause cancer and birth defects or other reproductive harm.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
Overall Environmental Toxicity: Harmful to aquatic life. Harmful to aquatic life with long lasting effects.
The ecological assessment for this material is based on an evaluation of its components.
L - 306 Epoxy Paste Adhesive, Part A SDS: 0056483 Date Prepared: 03/02/2016 Page 7 of 9
Component / CAS No. Toxicity to Algae Toxicity to Fish Toxicity to Water Flea
Aluminosilicate Not available Not available Not available
1327-36-2
o-Cresol glycidyl ether Not available Not available Not available
2210-79-9
Silicon dioxide, amorphous EC50 = 440 mg/L - LC50 = 5000 mg/L - EC50 = 7600 mg/L -
112945-52-5 Pseudokirchneriella subcapitata Brachydanio rerio (96h) static Ceriodaphnia dubia (48h)
(72h)
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
US DOT
TRANSPORT CANADA
_____________________________________________________________________________
United States (USA): All components of this product are included on the TSCA Chemical Inventory or are not
required to be listed on the TSCA Chemical Inventory.
Canada: All components of this product are included on the Domestic Substances List (DSL) or are not required to
be listed on the DSL.
European Economic Area (including EU): When purchased from a Cytec legal entity based in the EU, this
product is compliant with the registration of the REACH Regulation (EC) No. 1907/2006 as all its components are
either excluded, exempt, pre-registered and/or registered.
Australia: All components of this product are included in the Australian Inventory of Chemical Substances (AICS)
or are not required to be listed on AICS.
China: All components of this product are included on the Chinese inventory or are not required to be listed on the
Chinese inventory.
Japan: One or more components of this product are NOT included on the Japanese (ENCS) inventory.
Korea: All components of this product are included on the Korean (ECL) inventory or are not required to be listed
on the Korean inventory.
Philippines: All components of this product are included on the Philippine (PICCS) inventory or are not required to
be listed on the Philippine inventory.
This product does not contain any components regulated under these sections of the EPA
Instability: 0 - Materials that in themselves are normally stable, even under fire exposure conditions.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
Prepared By: Legal & Compliance Services; E-mail: custinfo@cytec.com
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
This information is given without any warranty or representation. We do not assume any legal responsibility for same, nor do we give permission,
inducement, or recommendation to practice any patented invention without a license. It is offered solely for your consideration, investigation, and
verification. Before using any product, read its label.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
SDS: 0056484
Date Prepared: 05/23/2016
SAFETY DATA SHEET
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
1. IDENTIFICATION
Product Name: L - 306 Epoxy Paste Adhesive, Part B
Product Description: Polyamide resin
Synonyms: None
Molecular Formula: Mixture
Molecular Weight: Mixture
Intended/Recommended Use: Engineered materials
CYTEC INDUSTRIES INC., FIVE GARRET MOUNTAIN PLAZA, WOODLAND PARK, NEW JERSEY 07424, USA
For Product and all Non-Emergency Information call 1-800/652-6013. Outside the USA and Canada call 1-973/357-
3193.
EMERGENCY PHONE (24 hours/day) - For emergency only involving spill, leak, fire, exposure or accident call:
Asia Pacific:
Australia - +61-3-9663-2130 or 1800-033-111 (IXOM)
China (PRC) - +86 0532 83889090 (NRCC)
New Guinea - +61-3-9663-2130 or 1800-033-111
New Zealand - +61-3-9663-2130 or 0800-734-607 (IXOM)
India, Japan, Korea, Malaysia, Thailand - +65 3158 1074 (Carechem24 Singapore)
India (Hindi Speaking Only) - +65 3158 1198 or 000800 100 7479 (Carechem24 Singapore)
Canada: +1-905-356-8310 (Cytec Welland, Canada plant)
Europe/Africa/Middle East (Carechem24 UK):
Europe, Middle East, Africa, Israel - +44 (0) 1235 239 670
(Arabic speaking countries) - +44 (0) 1235 239 671
Latin America:
Brazil - 0800 7077 022 (SUATRANS)
Chile - +56-2-2-247-3600 (CITUC QUIMICO)
All Others - +52-376-73 74122 (Cytec Atequiza, Mexico plant)
USA: +1-703-527-3887 or 1-800-424-9300 (CHEMTREC #CCN6083)
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
2. HAZARDS IDENTIFICATION
GHS Classification
Acute Toxicity (Inhalation) Hazard Category 4
Skin Corrosion / Irritation Hazard Category 1B
Serious Eye Damage / Eye Irritation Hazard Category 1
Skin Sensitizer Hazard Category 1A
Aquatic Environment Acute Hazard Category 2
Aquatic Environment Chronic Hazard Category 2
LABEL ELEMENTS
L - 306 Epoxy Paste Adhesive, Part B SDS: 0056484 Date Prepared: 05/23/2016 Page 2 of 11
Signal Word
Danger
Hazard Statements
Harmful if inhaled
Causes severe skin burns and eye damage
May cause an allergic skin reaction
Toxic to aquatic life with long lasting effects
Precautionary Statements
Use only outdoors or in a well-ventilated area.
Do not breathe dust/fume/gas/mist/vapours/spray.
Wash face, hands and any exposed skin thoroughly after handling.
Wear protective gloves/protective clothing/eye protection/face protection.
Contaminated work clothing should not be allowed out of the workplace.
Avoid release to the environment.
IF INHALED: Remove person to fresh air and keep comfortable for breathing.
IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
Wash contaminated clothing before reuse.
Immediately call a POISON CENTER or doctor/physician.
Specific treatment (see supplemental first aid instructions on this label).
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue
rinsing.
Store locked up.
Dispose of contents/container in accordance with local and national regulations.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
3. COMPOSITION/INFORMATION ON INGREDIENTS
Substance, Mixture or Article? Mixture
HAZARDOUS INGREDIENTS
The specific chemical identity and/or exact percentage of composition for one or more ingredients has been withheld as a
trade secret.
Additional GHS classification or other information may be included in this section but has not been adopted by OSHA.
See Section 16 for full text of H phrases.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
Eye Contact:
Rinse immediately with plenty of water for at least 15 minutes. Obtain medical attention immediately.
Skin Contact:
Remove contaminated clothing and shoes without delay. Wear impermeable gloves. Wash immediately with plenty
of water. Pay particular attention to skin crevices, nail folds, etc. Do not reuse contaminated clothing without
laundering. Do not reuse contaminated leatherware. Obtain medical attention.
Ingestion:
If swallowed, call a physician immediately. Only induce vomiting at the instruction of a physician. Never give
anything by mouth to an unconscious person.
Inhalation:
Remove to fresh air. If breathing is difficult, give oxygen. Obtain medical advice if there are persistent symptoms.
None known
Not applicable
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing Media:
Use water spray, alcohol foam, carbon dioxide or dry chemical to extinguish fires. Water stream may be ineffective.
Protective Equipment:
Firefighters, and others exposed, wear self-contained breathing apparatus. Wear full firefighting protective clothing. See
MSDS Section 8 (Exposure Controls/Personal Protection).
Special Hazards:
Keep containers cool by spraying with water if exposed to fire.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
L - 306 Epoxy Paste Adhesive, Part B SDS: 0056484 Date Prepared: 05/23/2016 Page 4 of 11
Special Handling Statements: Provide good ventilation of working area (local exhaust ventilation if necessary).
STORAGE
Store in accordance with local, state, and federal regulations.
Storage Temperature: Store at 25 °C 77 °F
Reason: Quality.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
Respiratory Protection:
Where exposures are below the established exposure limit, no respiratory protection is required. Where exposures
exceed the established exposure limit, use respiratory protection recommended for the material and level of exposure. A
full facepiece respirator also provides eye and face protection.
Eye Protection:
Prevent eye and skin contact. Provide eye wash fountain and safety shower in close proximity to points of potential
exposure. Wear eye/face protection such as chemical splash proof goggles or face shield.
Skin Protection:
Prevent contamination of skin or clothing when removing protective equipment. Barrier creams may be used in
conjunction with the gloves to provide additional skin protection. Wear impermeable gloves and suitable protective
clothing. Since this product is absorbed through the skin, care must be taken to prevent skin contact and contamination of
clothing.
Hand Protection:
Nitrile rubber gloves. Consider the porosity and elasticity data of the glove manufacturer and the specific conditions in the
work place.
Additional Advice:
Food, beverages, and tobacco products should not be carried, stored, or consumed where this material is in use. Before
eating, drinking, or smoking, wash face and hands thoroughly with soap and water.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
L - 306 Epoxy Paste Adhesive, Part B SDS: 0056484 Date Prepared: 05/23/2016 Page 5 of 11
Exposure Limit(s)
The below constituents are the only constituents of the product which have a PEL, TLV or other recommended exposure
limit. At this time, the other constituents have no known exposure limits.
111-40-0 Diethylenetriamine
OSHA (PEL): Not established
ACGIH (TLV): (skin)
1 ppm (TWA)
Other Value: Not established
112945-52-5 Silicon dioxide, amorphous
OSHA (PEL): 20 mppcf
ACGIH (TLV): Not established
Other Value: Not established
1327-36-2 Aluminosilicate
OSHA (PEL): 20 mppcf
ACGIH (TLV): Not established
Other Value: Not established
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
oxides of carbon
Hazardous Decomposition
Products: Oxides of nitrogen
When heated to decomposition, it emits toxic fumes.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
ALLERGIC SENSITIZATION
Sensitization skin Sensitizing
Sensitization respiratory No data
GENOTOXICITY
OTHER INFORMATION
The product toxicity information above has been estimated.
Polyamide has acute oral (rat-female) and acute dermal (rat) LD50 values of >2000 g/kg and >2000 mg/kg, respectively.
Direct contact with this material may produce moderate skin irritation and severe eye irritation. This material produced
dermal sensitization when tested in the Local Lymph Node Assay.This substance is not mutagenic in the Ames Assay.
Based on testing conducted a structurally similar substance (analog) this material is not expected to be mutagenic in the
in vitro Mouse Lymphoma Assay and not clastogenic in the in vitro Chromosomal Aberrations Assay
L - 306 Epoxy Paste Adhesive, Part B SDS: 0056484 Date Prepared: 05/23/2016 Page 7 of 11
Triethylenetetramine (TETA) has acute oral (rat) and acute dermal (rabbit) LD50 values of 1716 mg/kg and 1465 mg/kg,
respectively. Direct contact with TETA can produce severe skin irritation with necrosis and moderate to severe eye
irritation. Skin contact may cause an allergic skin reaction. Inhalation of TETA may cause respiratory tract irritation/burns
and potential respiratory sensitization in sensitive individuals. TETA was mutagenic in the Ames test and produced
genetic damage in an E. coli differential repair assay but did not induce chromosomal aberrations in the in vivo mouse
micronucleus assay. TETA did not exhibit carcinogenic potential in a lifetime mouse skin painting study.
Diethylenetriamine has acute oral (rat) LD50 values of 1620 mg/kg. Diethylenetriamine has acute dermal (rabbit) LD50
values of 1090 mg//kg. The LC50 value (rat, aerosol, 4 hr) is 0.07 - 0.3 mg/l. No mortality was seen in rats exposed to
300 ppm for 8-hours. This substance may cause respiratory tract irritation. Repeated inhalation exposures can cause
asthmatic type responses. Direct contact with Diethylenetriamine may cause severe irritation and/or irreversible damage
(burns) to the eyes and skin. Repeated or prolonged dermal contact may cause allergic skin reactions. In the majority of
studies performed with microorganisms and in mammalian cell culture, a mutagenic effect was not found. A mutagenic
effect was also not observed in in vivo tests. The substance showed no carcinogenic activity in animals after chronic
administration to the skin. Under certain conditions the substance can form nitrosamines. Nitrosamines are carcinogenic
in animal studies.
Silicon Dioxide has acute oral (rat) LD50 values ranging from 3160 mg/kg to >7500 mg/kg. The LC50 (rat) following a 4-
hour inhalation study is >0.25 mg/L (maximum attainable concentration). Chronic and sub-chronic inhalation tests with
laboratory animals produced lung damage and death after the lung clearance mechanisms were overloaded. Amorphous
silica does not cause the lung diseases crystalline silica is known to cause.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
The ecological assessment for this material is based on an evaluation of its components.
Component / CAS No. Toxicity to Algae Toxicity to Fish Toxicity to Water Flea
Polyamide ErC50 = 4.11 mg/L - Green LC50 = 1-10 mg/L - Zebrafish EC50 = 1-10 mg/L - Daphnia
- Algae (72h) (96h) Magna (48h)
L - 306 Epoxy Paste Adhesive, Part B SDS: 0056484 Date Prepared: 05/23/2016 Page 8 of 11
Component / CAS No. Toxicity to Algae Toxicity to Fish Toxicity to Water Flea
Triethylenetetramine EC50 = 3.7 mg/L - LC50 = 570 mg/L - Poecilia EC50 = 31.1 mg/L - Daphnia
112-24-3 Pseudokirchneriella subcapitata reticulata (96h) semi-static magna (48h)
(96h) LC50 = 495 mg/L - Pimephales
EC50 = 2.5 mg/L - promelas (96h)
Desmodesmus subspicatus (72h)
EC50 = 20 mg/L -
Pseudokirchneriella subcapitata
(72h)
Diethylenetriamine EC50 = 1164 mg/L - LC50 = 1014 mg/L - Poecilia EC50 = 16 mg/L - Daphnia
111-40-0 Pseudokirchneriella subcapitata reticulata (96h) semi-static magna (48h)
(72h) LC50 = 248 mg/L - Poecilia
EC50 = 592 mg/L - reticulata (96h) static
Desmodesmus subspicatus (96h)
EC50 = 345.6 mg/L -
Pseudokirchneriella subcapitata
(96h)
Aluminosilicate Not available Not available Not available
1327-36-2
Silicon dioxide, amorphous EC50 = 440 mg/L - LC50 = 5000 mg/L - EC50 = 7600 mg/L -
112945-52-5 Pseudokirchneriella subcapitata Brachydanio rerio (96h) static Ceriodaphnia dubia (48h)
(72h)
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
US DOT
Dangerous Goods? X
Proper Shipping Name: Corrosive liquid, n.o.s.
Hazard Class: 8
Packing Group: II
UN/ID Number: UN1760
Transport Label Required: Corrosive
Marine Pollutant
Marine Pollutant
L - 306 Epoxy Paste Adhesive, Part B SDS: 0056484 Date Prepared: 05/23/2016 Page 9 of 11
Comments: Marine Pollutants - DOT requirements specific to Marine Pollutants do not apply to
non-bulk packagings transported by motor vehicles, rail cars or aircraft.
TRANSPORT CANADA
Dangerous Goods? X
Proper Shipping Name: Corrosive liquid, n.o.s.
Hazard Class: 8
Packing Group: II
UN Number: UN1760
Transport Label Required: Corrosive
Marine Pollutant
Marine Pollutant
Technical Name (N.O.S.): triethylenetetramine, diethylenetriamine, Polyamide
ICAO / IATA
Dangerous Goods? X
Proper Shipping Name: Corrosive liquid, n.o.s.
Hazard Class: 8
Packing Group: II
UN Number: UN1760
Transport Label Required: Corrosive
Marine Pollutant
Technical Name (N.O.S.): triethylenetetramine, diethylenetriamine, Polyamide
Dangerous Goods? X
Proper Shipping Name: Corrosive liquid, n.o.s.
Hazard Class: 8
UN Number: UN1760
Packing Group: II
Transport Label Required: Corrosive
Marine Pollutant
Marine Pollutant
Technical Name (N.O.S.): triethylenetetramine, diethylenetriamine, Polyamide
United States (USA): All components of this product are included on the TSCA Chemical Inventory or are not
required to be listed on the TSCA Chemical Inventory.
L - 306 Epoxy Paste Adhesive, Part B SDS: 0056484 Date Prepared: 05/23/2016 Page 10 of 11
Canada: All components of this product are included on the Domestic Substances List (DSL) or are not required to
be listed on the DSL.
European Economic Area (including EU): When purchased from a Cytec legal entity based in the EU, this
product is compliant with the registration of the REACH Regulation (EC) No. 1907/2006 as all its components are
either excluded, exempt, pre-registered and/or registered.
Australia: All components of this product are included in the Australian Inventory of Chemical Substances (AICS)
or are not required to be listed on AICS.
China: All components of this product are included on the Chinese inventory or are not required to be listed on the
Chinese inventory.
Japan: One or more components of this product are NOT included on the Japanese (ENCS) inventory.
Korea: All components of this product are included on the Korean (ECL) inventory or are not required to be listed
on the Korean inventory.
Philippines: All components of this product are included on the Philippine (PICCS) inventory or are not required to
be listed on the Philippine inventory.
This product does not contain any components regulated under these sections of the EPA
Instability: 0 - Materials that in themselves are normally stable, even under fire exposure conditions.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
Prepared By: Legal & Compliance Services; E-mail: custinfo@cytec.com
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−
This information is given without any warranty or representation. We do not assume any legal responsibility for same, nor do we give permission,
inducement, or recommendation to practice any patented invention without a license. It is offered solely for your consideration, investigation, and
verification. Before using any product, read its label.
−⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−