Focuspro th6000 Series
Focuspro th6000 Series
Guide
Programmable Thermostat
Need Help?
For assistance with this product please visit http://customer.honeywell.com
or call Honeywell Customer Care toll-free at 1-800-468-1502
Wallplate installation
1. Separate wallplate from thermostat. It's easier to grasp the wallplate
and remove it after completely
2. Mount wallplate as shown below. removing the battery holder.
MCR29434
M29433
Drill 3/16" holes for drywall. Drill 7/32" holes for plaster.
Mounting screws
Wire hole
Wall anchors
ENGLISH
Wallplate
MCR29435
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not
place the old control in the trash. Contact your local waste management authority for
instructions regarding recycling and proper disposal.
69-2695EFS— 01 2
Downloaded from www.Manualslib.com manuals search engine
FocusPRO TH6000 Series
®
Power options
Keep wires in this
shaded area Remove factory-
installed jumper
only for two-
transformer
systems.
Wiring
Terminal designations
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
TH6110D TH6110D
G W C Y R Rc G C Y R Rc
TH6220D TH6220D
Y2 W2 G W C Y R Rc L Aux G C Y R Rc
E
TH6320U TH6320U
Y2 W2 G W C Y R Rc L Y2 Aux G C Y R Rc
E MCR29438A
MCR29437A
3 69-2695EFS— 01
Downloaded from www.Manualslib.com manuals search engine
Installation Guide
Wiring
Wiring guide — conventional systems
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
69-2695EFS— 01 4
Downloaded from www.Manualslib.com manuals search engine
FocusPRO TH6000 Series
®
Wiring
Wiring guide — heat pump systems
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
MCR29453
5 69-2695EFS— 01
Downloaded from www.Manualslib.com manuals search engine
Installation Guide
Installer setup
Follow the procedure below to configure the thermostat to match the installed heat-
ing/cooling system, and customize feature operation as desired.
Function Setting
number
1 0
Done Next
MCR29454
5 Stage 1 heat cycle 5 For gas or oil furnaces of less than 90% efficiency
rate (CPH: cycles/ 1 For steam or gravity systems
hour)* 3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
6 Stage 2 heat cycle 5 For gas or oil furnaces of less than 90% efficiency
rate/Auxiliary heat 1 For steam or gravity systems
cycle rate (CPH)* 3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
7 Auxiliary heat cycle 5 For gas or oil furnaces of less than 90% efficiency
rate (CPH)* 1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
Only TH6320U 9 For electric furnaces
for 3H/2C Heat Pumps
9 Stage 1 compressor 3 Recommended for most compressors
cycle rate (CPH) [Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
Installer setup
Setup function Settings & options (factory default in bold)
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
10 Stage 2 compressor 3 Recommended for most compressors
cycle rate (CPH) [Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
10 0
MCR29455
To begin, press and hold the s and t Press s / t to turn system on/off.
buttons until the display changes. Press NEXT to advance to next test.
Press DONE to terminate system test.
System test System status
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted. ENGLISH
10 Heating system 0 Heat and fan turn off.
1 Stage 1 heat turns on. Fan turns on if Setup Function 1 is set to 1, 5,
9 or 10 OR Setup Function 3 is set to 1 **See page 6
2 Stage 2 heat turns on
3 Stage 3 heat turns on - TH6320U only
20 Emergency heating 0 Heat and fan turn off
system 1 Heat and fan turn on
30 Cooling system 0 Compressor and fan turn off
1 Compressor and fan turn on
2 Stage 2 compressor turns on
40 Fan system 0 Fan turns off
1 Fan turns on
7 69-2695EFS— 01
Downloaded from www.Manualslib.com manuals search engine
Installation Guide
Special functions
Auto Changeover (Setup Function 12): When set to Auto, the thermostat automatically selects
heating or cooling depending on the indoor temperature. The thermostat will automatically adjust
heat and cool settings to maintain a 3-degree separation (fixed). Note: If you select Auto Changeover
Only, the System Setting on the thermostat will stay locked in the Auto position, preventing the user
from changing it to Em Heat, Heat, Cool or Off.
Adaptive Intelligent Recovery™ (Setup Function 13): Allows the thermostat to “learn”
how long the furnace and air conditioner take to reach programmed temperature settings, so the
temperature is reached at the scheduled time.
Compressor Protection (Setup Function 15): Forces the compressor to wait a few minutes
before restarting, to prevent damage. During the wait time, the message Cool On or Heat On (heat
pumps only) will flash on the display.
Specifications
Temperature Ranges Electrical Ratings
• Heat: 40° to 90°F (4.5° to 32°C)
Terminal Voltage (50/60Hz) Running Current
• Cool: 50° to 99°F (10° to 37°C)
W Heating 20-30 Vac 0.02-1.0 A
Operating Ambient (Powerpile) 750 mV DC 100 mA DC
Temperature
• 32° to 120°F (0° to 48.9°C) W2 (Aux/E) Heating 20-30 Vac 0.02-1.0 A
Y Cooling 20-30 Vac 0.02-1.0 A
Shipping Temperature
• -20° to 120°F (-28.9° to 48.9°C) Y2 Cooling 20-30 Vac 0.02-1.0 A
G Fan 20-30 Vac 0.02-0.5 A
Operating Relative Humidity
• 5% to 90% (non-condensing) O/B Changeover 20-30 Vac 0.02-0.5 A
Thermostat programmable
Besoin d’aide?
Pour obtenir de l’assistance au sujet de ce produit,
consulter le http://customer.honeywell.com ou téléphoner sans frais
au Centre de service à la clientèle de Honeywell au 1 800 468-1502
MCR29434
M29433
Vis de montage
Trou du fil
Ancrages muraux
Plaque murale
FRANÇAIS
MCR29435
69-2695EFS— 01 2
Downloaded from www.Manualslib.com manuals search engine
FocusPRO Série TH6000
®
Options d’alimentation
Garder les fils dans
cette zone Enlever le cavalier
ombragée. installé en usine
uniquement
pour les
systèmes à deux
transformateurs.
Câblage
Désignation des bornes
Les zones ombragées ci-dessous s’appliquent seulement au TH6320U/TH6220D
ou selon les indications.
Bornes traditionnelles : Bornes de thermopompe :
Rc Alimentation de 24 V CA pour Rc Alimentation de 24 V CA pour
le transformateur de climatisation le transformateur de climatisation
R Alimentation de 24 V CA pour R Alimentation de 24 V CA pour
le transformateur de chauffage le transformateur de chauffage
W Relais de chauffage (stade 1) O/B Robinet de substitution
W2 Relais de chauffage (stade 2) Y Contacteur de compresseur (stade 1)
Y Contacteur du compresseur (stade 1) Y2 Contacteur du compresseur (stade 2)
-TH6320U seulement
Y2 Contacteur du compresseur (stade 2)
G Relais de la soufflante
G Relais de la soufflante
Aux/E Relais auxiliaire de chauffage/de
C Neutre 24 V CA. Pour les systèmes
à 2 transformateurs, utiliser le neutre pour chauffage d’urgence
le transformateur de climatisation L Envoie le signal de sortie lorsque réglé à
Em. Chauffage
C Neutre 24 V CA
TH6110D TH6110D
FRANÇAIS
G W C Y R Rc G C Y R Rc
TH6220D TH6220D
Y2 W2 G W C Y R Rc L Aux G C Y R Rc
E
TH6320U TH6320U
Y2 W2 G W C Y R Rc L Y2 Aux G C Y R Rc
E MCR29438A
MCR29437A
3 69-2695EFS— 01
Downloaded from www.Manualslib.com manuals search engine
Guide d’installation
Câblage
Guide de câblage – systèmes traditionnels
Les zones ombragées ci-dessous s’appliquent seulement au TH6320U/TH6220D ou selon les indications.
Système de Système de
chauffage seulement climatisation seulement G C Y R Rc
W C R Rc Rc Alimentation [1] MCR29445
Rc Alimentation [1] MCR29440
R [R+Rc relié par le cavalier] R [R+Rc reliés par le cavalier]
C Neutre 24 V CA [3] Y Contacteur de compresseur
W Relais de chauffage C Neutre 24 V CA [3]
G Relais de la soufflante
Système de
chauffage Système 2C/2C
seulement (Série 20) [5] W C Y R Rc
MCR29441
(1 transformateur) [6]
Y2 W2 G W C Y R Rc
Rc [R+Rc reliés par le cavalier] Rc Alimentation [1] MCR29446
R Borne de soupape « R » de Série 20 [1] R [R+Rc reliés par le cavalier]
Y Borne de soupape « W » de Série 20 Y Contacteur du compresseur (stade 1)
C Neutre 24 V CA [3] C Neutre 24 V CA [3]
W Borne de soupape « B » de Série 20 W Relais de chauffage (stade 1)
G Relais de la soufflante
Système de W2 Relais de chauffage (stade 2)
chauffage seulement C Y R Rc Y2 Contacteur du compresseur (stade 2)
(soupape de zone normalement ouverte) [5] MCR29442
Rc [R+Rc reliés par le cavalier] Système 2C/2C
R Alimentation [1] (2 transformateurs) [6]
Y Soupape de zone normalement ouverte Y2 W2 G W C Y R Rc
Rc Alimentation (transformateur de M29447
C Neutre 24 V CA [3] climatisation) [1, 2]
R Alimentation (transformateur
Système 1C/1C
de chauffage) [1, 2]
(2 transformateurs) G W C Y R Rc Y Contacteur du compresseur (stade 1)
Rc Alimentation (transformateur M29443
C Neutre 24 V CA [3, 4]
de climatisation) [1, 2] W Relais de chauffage (stade 1)
R Alimentation (transformateur G Relais de la soufflante
de chauffage) [1, 2]
W2 Relais de chauffage (stade 2)
Y Contacteur de compresseur
Y2 Contacteur du compresseur (stade 2)
C Neutre 24 V CA [3, 4]
W Relais de chauffage
Voir [Remarques] ci-dessous
G Relais de la soufflante
REMARQUES climatisations (2Heat/2Cool Conventional).
Spécifications des fils : [7] Lors de la configuration, régler le type de
FRANÇAIS
69-2695EFS— 01 4
Downloaded from www.Manualslib.com manuals search engine
FocusPRO Série TH6000
®
Câblage
Guide de câblage – systèmes de thermopompes
Les zones ombragées ci-dessous s’appliquent seulement au TH6320U/TH6220D ou selon les indications.
Système de Système de
thermopompe 1C/1F G C Y R Rc
thermopompe 2C/2F
L Y2 G C Y R Rc
Rc Alimentation [1] MCR29448 (TH6320U seulement) [9] MCR29451
R [R+Rc reliés par le cavalier] Rc Alimentation [1]
Y Contacteur de compresseur R [R+Rc reliés par le cavalier]
C Neutre 24 V CA [3] Y Contacteur du compresseur (stade 1)
O/B Robinet de substitution [7] C Neutre 24 V CA [3]
G Relais de la soufflante O/B Robinet de substitution [7]
G Relais de la soufflante
Système de Y2 Contacteur du compresseur (stade 2)
thermopompe 2C/1F L Envoie le signal de sortie lorsque
(TH6220D seulement) [8] L Aux G C Y R Rc réglé à Em. Chauffage [11]
E MCR29449A
Rc Alimentation [1]
R [R+Rc reliés par le cavalier] Système de
Y Contacteur de compresseur thermopompe 3C/2F
C Neutre 24 V CA [3] (TH6320U seulement) [8] L Y2 Aux G C Y R Rc
E MCR29452
O/B Robinet de substitution [7] Rc Alimentation [1]
G Relais de la soufflante R [R+Rc reliés par le cavalier]
Aux/E Relais auxiliaire de chauffage/ Y Contacteur du compresseur (stade 1)
de chauffage d’urgence C Neutre 24 V CA [3]
L Envoie le signal de sortie lorsque O/B Robinet de substitution [7]
réglé à Em. Chauffage [11] G Relais de la soufflante
Aux/E Relais auxiliaire de chauffage/
Système de de chauffage d’urgence
thermopompe 2C/1F Y2 Contacteur du compresseur (stade 2)
(TH6320U seulement) [8] L Aux G C Y R Rc
L Envoie le signal de sortie lorsque
Rc Alimentation [1] E MCR29450 réglé à Em. Chauffage [11]
R [R+Rc reliés par le cavalier]
Y Contacteur de compresseur
C Neutre 24 V CA [3]
O/B Robinet de substitution [7]
G Relais de la soufflante
Aux/E Relais auxiliaire de chauffage/
de chauffage d’urgence
L Envoie le signal de sortie lorsque
réglé à Em. Chauffage [11]
Voir [Remarques] à la page 4.
Installation du thermostat
MCR29453
5 69-2695EFS— 01
Downloaded from www.Manualslib.com manuals search engine
Guide d’installation
Configuration du système
Suivez la procédure ci-dessous pour configurer le thermostat pour correspondre au sys-
tème de chauffage et de climatisation installé, et pour paramétrer les fonctions tel que
voulu.
Réglage
Numéro de fonction
1 0
Done Next
MCR29454
Appuyer sur s ou t pour modifier les réglages.
Pour commencer, enfoncer et tenir les boutons s Appuyer sur NEXT pour passer à la fonction
et FAN jusqu’à ce que l’affichage change. suivante. Appuyer sur DONE pour quitter
la configuration et enregistrer les réglages.
Fonction de Réglages et options
configuration (réglages par défaut en gras)
Les zones ombragées ci-dessous s’appliquent seulement au TH6320U/TH6220D ou selon les indications.
1 Type de système 0 Traditionnel 1 chauffage/1 climatisation (1 heat/1 cool conventional)
1 Thermopompe 1 chauffage/1 climatisation (aucun chauffage auxiliaire)
(1 heat/1 cool heat pump)
2 Chauffage seulement (Heat only) – systèmes à 2 fils, soupapes de zone
à 3 fils (Série 20) et soupapes de zone normalement ouvertes
3 Chauffage seulement avec soufflante (Heat only with fan)
4 Climatisation seulement (Cool only)
5 Thermopompe 2 chauffage/1 climatisation (avec chauffage auxiliaire)
(1 heat/1 cool heat pump with aux. heat)
6 Traditionnel 2 chauffage/2 climatisation (2 heat/2 cool conventional)
7 Traditionnel 2 chauffage/1 climatisation (2 heat/1 cool conventional)
8 Traditionnel 1 chauffage/2 climatisations (1 heat/2 cool conventional)
9 Thermopompe 2 chauffage/2 climatisation (aucun chauffage auxiliaire)
(2 heat/2 cool heat pump) - TH6320U seulement
10 Thermopompe 3 chauffage/2 climatisation (avec chauffage auxiliaire)
(3 heat/2 cool heat pump with aux. heat) - TH6320U seulement
2 Robinet de substitution 0 Robinet de substitution (Changeover valve) (borne O/B activée
(Borne O/B) lors de la climatisation)
1 Robinet de substitution (Changeover valve) (borne O/B activée lors
du chauffage)
3 Commande de soufflante 0 Fournaise au gaz ou au mazout (Gas or oil furnace) –
(chauffage) l’équipement commande la soufflante durant le chauffage
1 Fournaise électrique – le thermostat commande la soufflante durant
le chauffage
5 Rythme de cycle 5 Pour systèmes au gaz naturel ou au mazout d’une efficacité
de chauffage de stade inférieure à 90 %
1 (CPH: cycles par heure)* 1 Pour systèmes à la vapeur ou gravitaires
3 Pour systèmes à l’eau chaude et systèmes de chauffage d’une efficacité
supérieure à 90 %
9 Pour fournaises électriques
6 Rythme de cycle de 5 Pour systèmes au gaz naturel ou au mazout d’une efficacité
FRANÇAIS
*[Autres options de rythme de cycle : 2, 4, 6, 7, 8, 10, 11 ou 12 cycles par heure] Suite à la page suivante
69-2695EFS— 01 6
Downloaded from www.Manualslib.com manuals search engine
FocusPRO Série TH6000
®
Configuration du système
Fonction de Réglages et options
configuration (réglages par défaut en gras)
Les zones ombragées ci-dessous s’appliquent seulement au TH6320U/TH6220D ou selon les indications.
10 Rythme de cycle de 3 Recommandé pour la plupart des compresseurs
compresseur de stade [Autres options de rythme de cycle : 1, 2, 4, 5 ou 6 CPH]
2 (CPH)
12 Substitution manuelle/ 0 Substitution manuelle (Heat/Cool/Off)
automatique 1 Substitution automatique (Heat/Cool/Auto/Off)
2 Substitution automatique seulement (Auto)
13 Adaptive 1 On **Voir page 8
Intelligent Recovery MC
0 Off
14 Affichage de la 0 Fahrenheit
température 1 Celsius
15 Protection du 5 Désactivation du compresseur de cinq minutes
compresseur [Autres options : désactivation de 0, 1, 2, 3 ou 4 minutes]
16 Format de l’horaire 0 5/2 (programmation de jours de semaine et de week-ends)
1 5/1/1 (programmation des jours de semaine, du samedi et du dimanche)
27 Crans de la fourchette de 90 Réglage maximum de température de chauffage est 90 °F (32 °C)
température de chauffage [Autres options : 40 °F à 89 °F (4.5 °C à 31.5 °C)]
28 Crans de la fourchette 50 Réglage minimum de température de climatisation est 50 °F (10 °C)
de température [Autres options : 51 °F à 99 °F (10.5 °C à 37 °C)]
de climatisation
10 0
MCR29455
Pour commencer, enfoncer et tenir les Appuyer sur s / t pour activer ou
touches s et t jusqu’à ce que l’affichage désactiver le système. Appuyer sur NEXT
change. pour passer à l’essai suivant. Appuyer sur
DONE pour terminer l’essai du système.
7 69-2695EFS— 01
Downloaded from www.Manualslib.com manuals search engine
Guide d’installation
Fonctions spéciales
Substitution automatique (Fonction de configuration 12) : Lorsque réglé à Auto, le thermostat
sélectionne automatiquement le chauffage ou la climatisation selon la température intérieure.
Le thermostat ajuste automatiquement les réglages pour maintenir un écart de 3 degrés (fixe).
Remarque : Si vous sélectionnez Substitution automatique seulement, le réglage du système dans
le thermostat demeurera verrouillé à la position Auto, empêchant l’utilisateur de le changer à Em
Heat, Heat, Cool ou Off.
Adaptative Intelligent Recovery (Fonction de configuration 13) : Permet au thermostat
MC
Spécifications
Fourchettes de température Cote électrique
• Chauffage : 40 ° à 90 °F (4,5 ° à 32 °C)
Borne Tension Courant de
• Climatisation : 50 ° à 99 °F (10 ° à 37 °C)
(50/60 Hz) fonctionnement
Température ambiante W Chauffage 20-30 V CA 0,02-1,0 A
de fonctionnement
(Pile) 750 mV CC 100 mA CC
• 32 ° à 120 °F (0 ° à 48,9 °C)
W2 (Aux/E) Chauffage 20-30 V CA 0,02-1,0 A
Température d’expédition
Y Climatisation 20-30 V CA 0,02-1,0 A
• -20° à 120 °F (-28,9 ° à 48,9 °C)
Y2 Climatisation 20-30 V CA 0,02-1,0 A
Humidité relative de fonctionnement G Soufflante 20-30 V CA 0,02-0,5 A
• 5 % à 90 % (sans condensation)
O/B Substitution 20-30 V CA 0,02-0,5 A
Dimensions L Sortie 20-30 V CA 0,02-0,5 A
• 3-9/16 po H x 5-13/16 po L x 1-1/2 po P
91 mm H x 147 mm L x 38 mm P
Termostato programable
¿Necesita asistencia?
Para obtener asistencia relacionada con este producto,
visite http://customer.honeywell.com o comuníquese con el número gratuito del
servicio de atención al cliente de Honeywell, llamando al 1-800-468-1502
MCR29434
M29433
Anclas de expansión
MCR29435
Cableado
Designación de terminales
Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos TH6320U y TH6220D
o según se indique.
Terminales convencionales: Terminales de la bomba de calor:
Rc 24 V CA desde el transformador Rc 24 V CA desde el transformador
del sistema de refrigeración de la refrigeración
R 24 V CA desde el transformador R 24 V CA desde el transformador
del sistema de calefacción de la calefacción
W Relé de calor (etapa 1) O/B Válvula inversora
W2 Relé de calor (etapa 2) Y Interruptor automático del compresor (etapa
1)
Y Interruptor automático del compresor (etapa
1) Y2 Interruptor automático del compresor (etapa
2) (únicamente TH6320U)
Y2 Interruptor automático del compresor (etapa
2) G Relé del ventilador
G Relé del ventilador Aux/E Relé de calor auxiliar/de emergencia
C 24 V CA. Para los sistemas de L Cuando se fija en Em. Heat, envía un flujo
2 transformadores, utilice cables de aire caliente.
comunes desde el transformador
de la refrigeración. C 24 V CA
TH6110D TH6110D
G W C Y R Rc G C Y R Rc
TH6220D TH6220D
Y2 W2 G W C Y R Rc L Aux G C Y R Rc
E
TH6320U TH6320U
ESPAÑOL
Y2 W2 G W C Y R Rc L Y2 Aux G C Y R Rc
E MCR29438A
MCR29437A
3 69-2695EFS— 01
Downloaded from www.Manualslib.com manuals search engine
Guía de instalación
Cableado
Guía de cableado: sistemas convencionales
Las áreas sombreadas que aparecen abajo sólo se utilizan para las series TH6320U y TH6220D
o según se indique.
NOTAS 2 refrigeradores.
Especificaciones del cable: [7] Durante la configuración de instalación, coloque
Use cable para termostato de calibre 18 a 22. la válvula de conversión en la posición O o B.
No se requiere cable blindado. [8] Durante la configuración de instalación, coloque
[1] Fuente de alimentación. Proporciona el medio el tipo de sistema en Bomba de calor de
de desconexión y la protección contra sobrecargas 2 calentadores y 1 refrigerador.
requeridos. [9] Durante la configuración de instalación, coloque
[2] Para sistemas de 2 transformadores, quite el puente. el tipo de sistema en Bomba de calor de
2 calentadores y 2 refrigeradores.
[3] Conexión común de 24 V CA opcional.
[10] Durante la configuración de instalación, coloque
[4] La conexión común debe provenir del transformador de
ESPAÑOL
69-2695EFS— 01 4
Downloaded from www.Manualslib.com manuals search engine
Serie FocusPRO TH6000 ®
Cableado
Guía de cableado: sistemas de bomba de calor
Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos TH6320U/
TH6220D o según se indique.
Sistema de bomba Sistema de bomba
de calor de 1 calentador de calor de 2 calentadores
y 1 refrigerador G C Y R Rc
y 2 refrigeradores
Rc Electricidad [1] MCR29448 (Únicamente TH6320U) [9] L Y2 G C Y R Rc
MCR29451
R [R+Rc unidos por un puente] Rc Electricidad [1]
Y Interruptor automático del compresor R [R+Rc unidos por un puente]
C 24 V CA [3] Y Interruptor automático del compresor (etapa 1)
O/B Válvula inversora [7] C 24 V CA [3]
G Relé del ventilador O/B Válvula inversora [7]
G Relé del ventilador
Sistema de bomba
de calor de 2 calentadores Y2 Interruptor automático del compresor (etapa 2)
y 1 refrigerador L Cuando se fija en Em. Heat, envía un flujo de aire
L Aux G C Y R Rc
(Únicamente TH6220D) [8] E MCR29449A
caliente. [11]
Rc Electricidad [1]
R [R+Rc unidos por un puente] Sistema de bomba
de calor de 3 calentadores
Y Interruptor automático del compresor y 2 refrigeradores
C 24 V CA [3] (Únicamente TH6320U) [10] L Y2 Aux G C Y R Rc
O/B Válvula inversora [7] E
Rc Electricidad [1] MCR29452
G Relé del ventilador
R [R+Rc unidos por un puente]
Aux/E Relé de calor auxiliar/de emergencia
Y Interruptor automático del compresor (etapa 1)
L Cuando se fija en Em. Heat, envía un flujo
C 24 V CA [3]
de aire caliente. [11]
O/B Válvula inversora [7]
Sistema de bomba G Relé del ventilador
de calor de 2 calentadores Aux/E Relé de calor auxiliar/de emergencia
y 1 refrigerador
(Únicamente TH6320U) [8] Y2 Interruptor automático del compresor (etapa 2)
L Cuando se fija en Em. Heat, envía un flujo de aire
Rc Electricidad [1] L Aux G C Y R Rc
E MCR29450 caliente. [11]
R [R+Rc unidos por un puente]
Y Interruptor automático del compresor
C 24 V CA [3]
O/B Válvula inversora [7]
G Relé del ventilador
Aux/E Relé de calor auxiliar/de emergencia
L Cuando se fija en Em. Heat, envía un flujo de aire
caliente. [11]
Vea las [notas] en la página 4.
MCR29453
5 69-2695EFS— 01
Downloaded from www.Manualslib.com manuals search engine
Guía de instalación
Configuración de instalación
Siga el procedimiento que aparece a continuación para configurar el termostato
a fin de que se corresponda con el sistema de calefacción y refrigeración instalado, y
seleccione las funciones según lo desee.
Número Configuración
de función
1 0
Done Next
MCR29454
Las áreas sombreadas que aparecen abajo sólo se utilizan para TH6320U/TH6220D o según se indique.
1 Tipo de sistema 0 1 calentador y 1 refrigerador convencional
1 1 bomba de calor con calentador y 1 refrigerador (sin calor aux.)
2 Sólo calor — sistemas de 2 cables, válvulas de separación de tres cables (serie 20)
y válvulas de separación normalmente abiertas
3 Sólo calor con ventilador
4 Sólo frío
5 Bomba de calor con 2 calentadores y 1 refrigerador (con calor aux.)
6 2 calentadores y 2 refrigeradores convencionales
7 2 calentadores y 1 refrigerador convencional
8 1 calentador y 2 refrigeradores convencionales
9 Bomba de calor con 2 calentadores y 2 refrigeradores (sin calor aux.) únicamente
en TH6320U
10 Bomba de calor con 3 calentadores y 2 refrigeradores (con calor aux.) únicamente
en TH6320U
69-2695EFS— 01 6
Downloaded from www.Manualslib.com manuals search engine
Serie FocusPRO TH6000 ®
Configuración de instalación
Funciones de la configuración Configuraciones y opciones (las que vienen
desde la fábrica aparecen en negrita)
Las áreas sombreadas que aparecen abajo sólo se utilizan para TH6320U/TH6220D o según se indique.
10 Rango de ciclos 3 Recomendado para la mayoría de los compresores
del compresor [otras opciones de rango de ciclos: 1, 2, 4, 5 ó 6 CPH]
de la etapa 2 (CPH)
10 0
MCR29455
Para comenzar, mantenga presionados
Presione s / t para encender o apagar el sistema.
los botones s y t Presione NEXT para avanzar hacia la próxima prueba.
hasta que cambie el visor Presione DONE para finalizar la prueba del sistema.
7 69-2695EFS— 01
Downloaded from www.Manualslib.com manuals search engine
Guía de instalación
Funciones especiales
Conveasor automático (configuración 12): Cuando el sistema está configurado en “Auto”,
el termostato elige automáticamente cuándo calentar o enfriar, dependiendo de la temperatura interior. El
termostato ajustará automáticamente las configuraciones de calor y frío a fin de
mantener una separación de 3 grados (fija). Nota: Si selecciona Auto Changeover Only (sólo conversión
automática), la configuración del termostato permanecerá bloqueada en la posición “Auto”, de modo que
el usuario no pueda cambiarla a Em.Heat, Heat, Cool u Off.
Adaptive Intelligent Recovery™ (configuración 13): Permite al termostato “saber” cuánto tiempo
requiere el sistema de aire acondicionado para alcanzar las configuraciones de temperatura programadas
a fin de alcanzar la temperatura deseada a la hora programada.
Protección del compresor (configuración 15): Hace que el compresor espere unos minutos
antes de reiniciarse, para prevenir daños. Durante el tiempo de espera, el mensaje Cool On
o Heat On (sólo para las bombas de calor) aparecerá parpadeando en la pantalla del visor.
Especificaciones
Rangos de temperatura Rangos eléctricos
• Calor: 40 °F a 90 °F (4,5 °C a 32 °C).
Terminal Voltaje (50/60 Hz) Corriente
• Frío: 50 °F a 99 °F (10 °C a 37 °C)
W Calefacción 20-30 V CA 0,02 -1,0 A
Temperatura ambiente operativa
• 32° a 120 °F (0° a 48,9 °C) (Powerpile) 750 mV CC 100 mA CC
W2 (Aux/E) Calefacción 20-30 V CA 0,02 -1,0 A
Temperatura de embalaje
• -20° a 120 °F (-28,9 °C a 48,9 °C) Y Refrigeración 20-30 V CA 0,02 -1,0 A