Engine Crec Generic Scan Tool Eng
Engine Crec Generic Scan Tool Eng
Repair Manual
Q7 2016 ➤
Generic Scan Tool
Engine ID
CRE
C
Edition 11.2016
Repair Group
ST - Generic Scan Tool
Technical information should always be available to the foremen and mechanics, because their
careful and constant adherence to the instructions is essential to ensure vehicle road-worthiness and
safety. In addition, the normal basic safety precautions for working on motor vehicles must, as a
matter of course, be observed.
Q7 2016 ➤
Generic Scan Tool - Edition 11.2016
Contents
Contents i
Q7 2016 ➤
Generic Scan Tool - Edition 11.2016
ii Contents
Q7 2016 ➤
Generic Scan Tool - Edition 11.2016
1. General Information 1
Q7 2016 ➤
Generic Scan Tool - Edition 11.2016
WARNING
Caution
1. General Information 3
Q7 2016 ➤
Generic Scan Tool - Edition 11.2016
WARNING
WARNING
1. General Information 5
Q7 2016 ➤
Generic Scan Tool - Edition 11.2016
When Working on the Following Compo‐ The High Voltage System Must Be Minimum Qualifications,
nents De-energized By A High Voltage refer to ⇒ page 9
Technician Prior To Beginning the
Work?
Yes No
Electro-Drive Drive Motor - V141- X Technician trained in
electrical systems
Electric Drive Power and Control Electron‐ X Technician trained in
ics - JX1- electrical systems
High Voltage System Maintenance Con‐ X Technician trained in
nector - TW- electrical systems
Electric A/C Compressor High Voltage Ca‐ X Technician trained in
ble - P3- electrical systems
Drive Motor High Voltage Wiring Harness - X Technician trained in
PX2- electrical systems
High Voltage Wiring Harness For High Volt‐ X Technician trained in
age Battery - PX1- electrical systems
Hybrid Battery Unit - AX1- , Removing and X Technician trained in
Installing electrical systems
Charging the Hybrid-Battery - A38- with X High voltage technician
High Voltage Battery Charger - VAS6565-
Battery Regulation Control Module - J840- X High voltage technician
Battery Fan 1 - V457- X Technician trained in
electrical systems
Air guides next to the Hybrid Battery Unit - X Technician trained in
AX1- electrical systems
Air guides under the Hybrid Battery Unit - X Technician trained in
AX1- electrical systems
Electrical A/C Compressor - V470- X Technician trained in
electrical systems
Drive Motor Temperature Sensor - G712- X Technician trained in
electrical systems
Drive Motor Rotor Position Sensor 1 - X Technician trained in
G713- electrical systems
When Working on the Following Compo‐ The High Voltage System Must Be Minimum Qualifications,
nents De-energized By A High Voltage refer to ⇒ page 9
Technician Prior To Beginning the
Work?
Yes No
Three-Phrase Current Drive - VX54- X Technician trained in
electrical systems
Electrical Drive Button - E656- X Technician trained in
electrical systems
Fuse Electrical A/C Compressor - V470- in X Technician trained in
Electric Drive Power and Control Electron‐ electrical systems
ics - JX1-
Potential equalization cable (Ground [GND] X Technician trained in
wires) electrical systems
Working on the coolant circuit for the high X Technician trained in
voltage components electrical systems
Measuring insulation resistance X High voltage technician
Working when the system is de-energized X Technician trained in
and the ignition is on electrical systems
1. General Information 7
Q7 2016 ➤
Generic Scan Tool - Edition 11.2016
When Working on the Following Compo‐ The High Voltage System Must Be Minimum Qualifications,
nents De-energized By A High Voltage refer to ⇒ page 9
Technician Prior To Beginning the
Work?
Yes No
When working near high voltage compo‐ X Technician trained in
nents and high voltage cables, do not use electrical systems
tools that generate heat, that have sharp
edges or that are used for cutting or shap‐
ing, such as welding, soldering, hot air or
thermal adhesive equipment (Cover high
voltage components with non-combustible
materials and then perform a visual inspec‐
tion).
Left Front Headlamp - MX1- , Removing X Technician trained in
and Installing electrical systems
Right Front Headlamp - MX2- , Removing X Technician trained in
and Installing electrical systems
Headlamp Bulbs, Removing and Installing X Technician trained in
electrical systems
General Work
When Working On the Following Compo‐ The High Voltage System Must Be Minimum Qualifications,
nents De-energized By A High Voltage refer to ⇒ page 9
Technician Prior To Beginning the
Work?
Yes No
12V Battery, removing and installing X Technician trained in
electrical systems
General controls modules and electric com‐ X Technician trained in
ponents, 12V, removing and installing electrical systems
Fluids, coolant and fluids, draining and fill‐ X Technician trained in
ing electrical systems
Refrigerant extracting, evacuating, filling X Technician trained in
electrical systems
Refrigerant pipes directly to the A/C com‐ X Technician trained in
pressor electrical systems
A/C System, flushing X Technician trained in
electrical systems
Peripheral refrigerant line (work that does X Technician trained in
not involve the A/C compressor directly electrical systems
without opening the refrigerant circuit, for
example, loosening and tightening the re‐
frigerant line)
Work with the engine raised, engine mount X Technician trained in
electrical systems
Emissions test X Technician trained in
electrical systems
Follow the instructions in the paint hand‐ X Technician trained in
book when performing any paint/drying electrical systems
work
Qualification Explanation
Qualification Area of Application
Hybrid electrically instructedMay perform general work and
person Maintenance services on the
vehicle. May be requested by
the high voltage technician to
perform mechanical work on
the tension-free high voltage
system.
High voltage technician (HVT) The high voltage technician has
the same authorization as a
technician trained in electrical
systems due to their qualifica‐
tions. The high voltage techni‐
cian can also:
♦ 1. De-energize the system.
♦ 2. Secure the system so that
it cannot be energized
again.
♦ 3. Ascertain that the system
is definitely de-energized
(certified measurement).
♦ 4. Assign work on the high
voltage system to the hybrid
electrically instructed per‐
son.
♦ 5 Put the vehicle back in op‐
eration.
1. General Information 9
Q7 2016 ➤
Generic Scan Tool - Edition 11.2016
Note
5 • FAULT: Intermittent or a sporadic condition. ♦ Perform a road test to verify the repair.
• CHECK: Suspected components. ♦ Generate readiness code. Refer to
⇒ “3.2 Readiness Code”, page 21 .
• PERFORM: Visual Inspection of wiring and
components.
• CHECK: Wiring for open, high resistance,
short or harness connector for damage, corro‐
sion, loose or broken terminals.
• REPAIR: Faulty wiring or connector.
Caution
Note
Do not assume that the scan tool ID and engine code are correct
if the scan tool communicates. The scan tool does not use the ID
to establish communication—the units are automatically identi‐
fied.
Test requirements
• NO DTC in memory.
• Switch OFF all electrical and electronic accessories.
• Necessary driving speed: 50 – 70 mph.
• Drive profile takes approximately 60 – 90 min.
Readiness Drive Cycle Procedure
– CONNECT: Scan Tool.
Step Procedure Result / Action to Take
1 Activate Monitors: ♦ Monitoring Active.
• START: Engine and idle for 2 – 3 min.
♦ Executes Misfire Monitoring.
5 Secondary Air Injection, EVAP Monitoring: ♦ Executes Secondary Air Injection Monitoring.
• DRIVE: Vehicle for 30 – 40 min. at a constant
speed of 50 – 70 mph in high gear for 2 min ♦ Executes EVAP Monitoring.
with no coasting. • Check the status of the readiness code.
– If any engine monitor fails the drive cycle test. Repeat the drive
cycle test until all engine monitors have successfully run
through and passed.
Note
Note
Procedure
– Connect the scan tool.
– Start the engine and run at idle.
Note
If the engine does not start, crank the engine using starter for at
least 5 seconds, do not switch the ignition off afterward under any
circumstances.
Note
Component group
Repair group
P x 0 x x Fuel and air mixture and additional emission regulations
P x 1 x x Fuel and air ratios
P x 2 x x Fuel and air ratios
P x 3 x x Ignition system
P x 4 x x Additional exhaust system
P x 5 x x Speed and idle control
P x 6 x x Control module and output signals
P x 7 x x Transmission
P x 8 x x Transmission
P x 9 x x Control modules, input and output signals
U-Codes
Component group
U x x x x DTC for network (CAN bus)
Norm-Code
U 0 x x x Trouble codes defined by SAE with specified malfunction
texts
Procedure
– Connect the scan tool.
– Switch the ignition to the ON position.
– Select Diagnostic Mode 03: Interrogating fault memory.
– The stored DTC or DTCs will be displayed on the scan tool
screen.
The following table is an example of the DTC information that may
be displayed on the scan tool screen:
Indication example Explanation
P0444 SAE Diagnostic Trouble Code
Evaporative emission canister purge regulator valve Malfunctioning wiring path or malfunctioning compo‐
nent
– Refer to the DTC tables below for the diagnostic repair pro‐
cedures.
♦ ⇒ “3.4.1 Engine Control Module , 2016 MY”, page 58
♦ ⇒ “3.4.2 Engine Control Module , 2017 MY”, page 442
– Switch the ignition off.
Note
Procedure
– Connect the scan tool.
– Switch the ignition on.
– Select Diagnostic Mode 03: Interrogating fault memory.
– Then select Mode 4: Reset/delete diagnostic data.
The scan tool will display: Diagnostic data are being erased.
– Switch the ignition off.
Note
Test Requirements
– No Test requirements are available for this powertrain.
Function Test
– No Function Tests are available for this powertrain.
procedure
⇒ “3.3.3 Diagnostic Mode 03 - Read DTC Memory”,
page 27 .
– Switch the ignition off.
Monitor $02: Oxygen Sensor Monitor Bank 1 – Sensor 2
– Connect the scan tool.
– Start the engine and let run at idle speed.
– Select “Diagnostic Mode 6: Check test the results of compo‐
nents that are not continuously monitored”.
Select “Monitor $02”.
– Select the desired “Test-ID” or “Hex-ID”.
– Check specified values at idle.
Test- DTC Component or System Min. Max. Additional Information
ID
$05 P013A Oxygen Sensor Signal Rich To 800.0 65,534.0 Refer to DTC P013A in the DTC
Lean Switching Time. mV/s mV/s summary table. ⇒ page 111
$92 P013B Oxygen Sensor Signal Gradient 800.0 65,534.0 Refer to DTC P013B in the DTC
Of Lean To Rich Transition Time. mV/s mV/s summary table. ⇒ page 115
$93 P013E Oxygen Sensor Signal Dynamic 0.0 s 0.8 s Refer to DTC P013E in the DTC
Testing Delayed Response Rich summary table. ⇒ page 127
To Lean.
$94 P013F Oxygen Sensor Signal Dynamic 0.0 s NaN s Refer to DTC P013F in the DTC
Testing Delayed Response Lean summary table. ⇒ page 131
To Rich.
$95 P2270 Oxygen Sensor Target Voltage 0.82 V 7.999 V Refer to DTC P2270 in the DTC
Rich Condition Not Reached. summary table. ⇒ page 385
$96 P2271 Oxygen Sensor Target Voltage 0.0 V 0.15 V Refer to DTC P2271 in the DTC
Lean Condition Not Reached. summary table. ⇒ page 389
Note
Procedure
– Connect the scan tool.
– Start the engine and run at idle.
Note
If the engine does not start, crank the engine using starter for at
least 5 seconds. Do not switch the ignition off afterward.
Note
If the accelerator pedal is depressed during the test, the test will
be aborted.
Note
Test requirement
• No DTCs stored in the DTC memory.
Procedure
– Connect the scan tool.
– Switch the ignition on.
– Select Mode 09: Vehicle information.
– Select the desired Test-ID.
– The information requested will be displayed on the scan tool
screen.
The following table is a numerical list of all Test-IDs that may be
selected.
Test-ID Diagnostic text
02: Vehicle identification number e.g.
♦ A different 17 digit number will be displayed for each vehicle
♦ 000D105
0A ECU Name
♦ Engine Control Module (ECM)
Note
Note
Procedure
♦ Erasing Permanent Fault Codes after code clear Service $0A
– Permanent Fault Codes: can only be erased at the end of a
driving cycle (during ECM keep alive time) if all the following
conditions are fulfilled:
♦ ERASE: Permanent Fault Codes after code clear, the vehicle
needs to be driven !
♦ NO FAIL: DTC cleared
♦ MONITORS: PASS
♦ MINIMUM: Conditions fulfilled 600 s. (cumulative) Engine run‐
ning
♦ DRIVE: 300.0 s (cumulative) vehicle speed > 25 mph (40 km/
h)
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P000B VVT Ac‐ • Adjustment • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"B" Cam‐ tuator angle differ‐ perature 15 – (FTP75: Exhaust
shaft Posi‐ Outlet ence >= 130° C 700.0) s Camshaft
tion Slow Rationali‐ 0.75; < Adjustment
Response ty Check 7.00° CRK • Engine speed • Continu‐ Valve 1 -
Bank 1 608 – 7,008 ous N318- . Re‐
RPM fer to
• Set point ⇒ “3.6.21
change > 14.0° Exhaust
CRK Camshaft
Adjustment
• Camshaft posi‐ Valve 1
tion not @ max. N318 ,
stop position Checking”,
page 936 .
• Dynamic diag‐
nosis timer >=
0.95 – 4.18 s
P000C VVT Ac‐ • Adjustment • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"A" Cam‐ tuator In‐ angle differ‐ perature 15 – (FTP75: Camshaft
shaft Posi‐ take ence >= 130° C 300.0) s Adjustment
tion Slow Bank 2 0.75; < Valve 2 -
Response Rationali‐ 7.00° CRK • Engine speed • Continu‐ N208- . Re‐
Bank 2 ty Check 608 – 7,008 ous fer to
RPM ⇒ “3.6.3
• Set point Camshaft
change > 14.0° Adjustment
CRK Valve 2
N208 ,
• Camshaft posi‐ Checking”,
tion not @ max. page 899 .
stop position
• Dynamic diag‐
nosis timer >=
0.95 – 4.18 s
P000D VVT Ac‐ • Adjustment • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"B" Cam‐ tuator angle differ‐ perature 15 – (FTP75: Exhaust
shaft Posi‐ Outlet ence >= 130° C 700.0) s Camshaft
tion Slow Bank 2 0.75; < Adjustment
Response Rationali‐ 7.00° CRK • Engine speed • Continu‐ Valve 2 -
Bank 2 ty Check 608 – 7,008 ous N319- . Re‐
RPM fer to
• Set point ⇒ “3.6.22
change > 14.0° Exhaust
CRK Camshaft
Adjustment
• Camshaft posi‐ Valve 2
tion not @ max. N319 ,
stop position Checking”,
page 938 .
• Dynamic diag‐
nosis timer >=
0.95 – 4.18 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0010 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"A" Cam‐ tuator In‐ age lower tor solenoid Camshaft
shaft Posi‐ take range 1.92 valve comman‐ • Continu‐ Adjustment
tion Actua‐ Open Cir‐ – 2.21 V ded off ous Valve 1 -
tor Control cuit N205- . Re‐
Circuit/ • Output volt‐ fer to
Open age upper ⇒ “3.6.2
Bank 1 range Camshaft
(hardware Adjustment
values) Valve 1
2.85 – 3.25 N205 ,
V Checking”,
page 897 .
P0011 VVT Ac‐ • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"A" Cam‐ tuator In‐ position de‐ perature 15 – (FTP75: Camshaft
shaft Posi‐ take Ra‐ viation > 130° C 1,000.0) Adjustment
tion - Tim‐ tionality 10.0° CRK s Valve 1 -
ing Over- Check • Engine speed N205- . Re‐
Advanced 608 – 7,008 • Continu‐ fer to
or System RPM ous ⇒ “3.6.2
Perform‐ • Camshaft posi‐ Camshaft
ance Bank tion not @ max. Adjustment
1 stop position Valve 1
N205 ,
• Camshaft posi‐ Checking”,
tion adjustment page 897 .
active
• Catalyst heating
not active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 9.0°
CRK times s
P0013 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator age lower tor solenoid Exhaust
shaft Posi‐ Outlet range 1.92 valve comman‐ • Continu‐ Camshaft
tion Actua‐ Open Cir‐ – 2.21 V ded on ous Adjustment
tor Control cuit Valve 1 -
Circuit/ • Output volt‐ N318- . Re‐
Open age upper fer to
Bank 1 range ⇒ “3.6.21
(hardware Exhaust
values) Camshaft
2.85 – 3.25 Adjustment
V Valve 1
N318 ,
Checking”,
page 936 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0014 VVT Ac‐ • Difference • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"B" Cam‐ tuator between perature 15 – (FTP75: Exhaust
shaft Posi‐ Outlet target and 130° C 450.0) s Camshaft
tion - Tim‐ Rationali‐ actual posi‐ Adjustment
ing Over- ty Check tion > 10.0° • Engine speed • Continu‐ Valve 1 -
Advanced CRK 608 – 7,008 ous N318- . Re‐
or System RPM fer to
Perform‐ • Camshaft posi‐ ⇒ “3.6.21
ance Bank tion not @ max. Exhaust
1 stop position Camshaft
Adjustment
• Camshaft posi‐ Valve 1
tion adaptation N318 ,
active Checking”,
page 936 .
• Catalyst heating
not active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 9.0°
CRK times s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0016 Camshaft • Adapted • Camshaft phas‐ • 720.0° • 2 DCY – Check the
Crank‐ Position/ value for ing commanded CRK Camshaft
shaft Posi‐ Crank‐ each edge (exhaust side) Adjustment
tion - Cam‐ shaft Po‐ of the target • Multiple Valve 1 -
shaft Posi‐ sition In‐ wheel < • Engine speed N205- . Re‐
tion Corre‐ take - -19.0° CRK 288 – 8,000 fer to
lation Correla‐ RPM ⇒ “3.6.2
Bank 1 tion Val‐ • Or
• Modeled oil tem‐ Camshaft
Sensor A ue Moni‐ • Adapted perature >= -40° Adjustment
toring value for C Valve 1
each edge N205 ,
of the target • Modeled oil tem‐ Checking”,
wheel > perature <= 130 page 897 .
19.0° CRK – 160° C
• Engine speed <
8,160 RPM
• Diff. actual ex‐
haust camshaft
position vs. pre‐
vious camshaft
position @ refer‐
ence signal
edge < 2.0° CRK
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0017 Camshaft • Adapted • Camshaft phas‐ • 720.0° • 2 DCY – Check the
Crank‐ Position/ value for ing commanded CRK Exhaust
shaft Posi‐ Crank‐ each edge on (exhaust Camshaft
tion - Cam‐ shaft Po‐ of the target side) • Multiple Adjustment
shaft Posi‐ sition Ex‐ wheel < Valve 1 -
tion Corre‐ haust - -19.0° CRK • Engine speed N318- . Re‐
lation Correla‐ 288 – 8,000 fer to
Bank 1 tion • Or RPM ⇒ “3.6.21
Sensor B Adapta‐ • Adapted • Modeled oil tem‐ Exhaust
tion Val‐ value for perature >= -40° Camshaft
ue Moni‐ each edge C Adjustment
toring of the target Valve 1
wheel > • Modeled oil tem‐ N318 ,
19.0° CRK perature <= 130 Checking”,
– 160° C page 936 .
• Engine speed <
8,160 RPM
• Diff. actual ex‐
haust camshaft
position vs. pre‐
vious camshaft
position @ refer‐
ence signal
edge < 2.0° CRK
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0018 Camshaft • Adapted • Camshaft phas‐ • 720.0° • 2 DCY – Check the
Crank‐ Position value for ing commanded CRK Camshaft
shaft Posi‐ 2 / Crank‐ each edge on (exhaust Position
tion - Cam‐ shaft Po‐ of the target side) • Multiple Sensor 2 -
shaft Posi‐ sition In‐ wheel < G163- . Re‐
tion Corre‐ take - -19.0° CRK • Engine speed fer to
lation Correla‐ 288 – 8,000 ⇒ “3.6.5
Bank 2 tion • Or RPM Camshaft
Sensor A Adapta‐ • Adapted • Modeled oil tem‐ Position
tion Val‐ value for perature >= -40° Sensor 2
ue Moni‐ each edge C G163 ,
toring of the target Checking”,
wheel > • Modeled oil tem‐ page 903 .
19.0° CRK perature <= 130
– 160° C
• Engine speed <
8,160 RPM
• Diff. actual ex‐
haust camshaft
position vs. pre‐
vious camshaft
position @ refer‐
ence signal
edge < 2.0° CRK
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0019 Camshaft • Adapted • Camshaft phas‐ • 720.0° • 2 DCY – Check the
Crank‐ Position value for ing commanded CRK Camshaft
shaft Posi‐ 2 / Crank‐ each edge on (exhaust Position
tion - Cam‐ shaft Po‐ of the target side) • Multiple Sensor 4 -
shaft Posi‐ sition Ex‐ wheel < G301- . Re‐
tion Corre‐ haust - -19.0° CRK • Engine speed fer to
lation Correla‐ 288 – 8,000 ⇒ “3.6.7
Bank 2 tion • Or RPM Camshaft
Sensor B Adapta‐ • Adapted • Modeled oil tem‐ Position
tion Val‐ value for perature >= -40° Sensor 4
ue Moni‐ each edge C G301 ,
toring of the target Checking”,
wheel > • Modeled oil tem‐ page 908 .
19.0° CRK perature <= 130
– 160° C
• Engine speed <
8,160 RPM
• Diff. actual ex‐
haust camshaft
position vs. pre‐
vious camshaft
position @ refer‐
ence signal
edge < 2.0° CRK
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0020 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"A" Cam‐ tuator In‐ age, lower tor solenoid Camshaft
shaft Posi‐ take range 1.92 valve comman‐ • Continu‐ Adjustment
tion Actua‐ Bank 2 – 2.21 V ded off ous Valve 2 -
tor Control Open Cir‐ N208- . Re‐
Circuit/ cuit • Output volt‐ fer to
Open age, upper ⇒ “3.6.3
Bank 2 range Camshaft
(hardware Adjustment
values) Valve 2
2.85 – 3.25 N208 ,
V Checking”,
page 899 .
P0021 VVT Ac‐ • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"A" Cam‐ tuator In‐ position de‐ perature 15 – (FTP75: Camshaft
shaft Posi‐ take viation > 130° C 1,000.0) Adjustment
tion - Tim‐ Bank 2 10.0° CRK s Valve 2 -
ing Over- Rationali‐ • Engine speed N208- . Re‐
Advanced ty Check 608 – 7,008 • Continu‐ fer to
or System RPM ous ⇒ “3.6.3
Perform‐ • Camshaft posi‐ Camshaft
ance Bank tion not @ max. Adjustment
2 stop position Valve 2
N208 ,
• Camshaft posi‐ Checking”,
tion adaptation page 899 .
active
• Catalyst heating
not active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 9.0°
CRK times s
P0023 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator age, lower tor solenoid Exhaust
shaft Posi‐ Outlet range 1.92 valve comman‐ • Continu‐ Camshaft
tion Actua‐ Bank 2 – 2.21 V ded on ous Adjustment
tor Control Open Cir‐ Valve 2 -
Circuit/ cuit • Output volt‐ N319- . Re‐
Open age, upper fer to
Bank 2 range ⇒ “3.6.22
(hardware Exhaust
values) Camshaft
2.85 – 3.25 Adjustment
V Valve 2
N319 ,
Checking”,
page 938 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0024 VVT Ac‐ • Difference • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"B" Cam‐ tuator between perature 15 – (FTP75: Exhaust
shaft Posi‐ Outlet target and 130° C 600.0) s Camshaft
tion - Tim‐ Bank 2 actual posi‐ Adjustment
ing Over- Rationali‐ tion > 10.0° • Engine speed • Continu‐ Valve 2 -
Advanced ty Check CRK 608 – 7,008 ous N319- . Re‐
or System RPM fer to
Perform‐ • Camshaft posi‐ ⇒ “3.6.22
ance Bank tion not @ max. Exhaust
2 stop position Camshaft
Adjustment
• Camshaft posi‐ Valve 2
tion adaptation N319 ,
active Checking”,
page 938 .
• Catalyst heating
not active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 9.0°
CRK times s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0032 Oxygen • O2S up‐ • EGT @ O2S • 2.5 s • 2 DCY – Check the
HO2S Sensors stream front >= -273° C Oxygen
Heater Heater heater driv‐ • Continu‐ Sensor 1
Control Front er tempera‐ • Actuator com‐ ous Before Cat‐
Circuit Short To ture > 160.0 manded on alytic Con‐
High Bank Battery – 200.0° C verter -
1 Sensor 1 Plus GX10- . Re‐
• Or fer to
• O2S up‐ ⇒ “3.6.39
stream Oxygen
heater driv‐ Sensor 1
er output Before Cat‐
current > alytic Con‐
8.0 – 12.0 A verter
GX10 ,
Checking”,
page 972 .
P0036 Oxygen • O2S down‐ • Engine not in • 2.5 s • 2 DCY – Check the
HO2S Sensors stream start process Oxygen
Heater Heater heater volt‐ • Continu‐ Sensor 1
Control Rear age, lower ous After Cata‐
Circuit Open Cir‐ range 1.92 lytic Con‐
Bank 1 cuit – 2.21 V verter -
Sensor 2 GX7- . Re‐
• O2S down‐ fer to
stream ⇒ “3.6.38
heater volt‐ Oxygen
age, upper Sensor 1
range 2.85 After Cata‐
– 3.25 V lytic Con‐
verter GX7 ,
Checking”,
page 970 .
P0037 Oxygen • O2S down‐ • Engine not in • 2.5 s • 2 DCY – Check the
HO2S Sensors stream start process Oxygen
Heater Heater heater volt‐ • Continu‐ Sensor 1
Control Rear age < 1.92 – ous After Cata‐
Circuit Short To 2.21 V lytic Con‐
Low Bank Ground verter -
1 Sensor 2 GX7- . Re‐
fer to
⇒ “3.6.38
Oxygen
Sensor 1
After Cata‐
lytic Con‐
verter GX7 ,
Checking”,
page 970 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0038 Oxygen • O2S down‐ • EGT @ O2S • 2.5 s • 2 DCY – Check the
HO2S Sensors stream front >= -273° C Oxygen
Heater Heater heater driv‐ • Continu‐ Sensor 1
Control Rear er tempera‐ • Heater com‐ ous After Cata‐
Circuit Short To ture > 160.0 manded on lytic Con‐
High Bank Battery – 200.0° C • Engine not in verter -
1 Sensor 2 Plus start process GX7- . Re‐
• Or fer to
• O2S down‐ ⇒ “3.6.38
stream Oxygen
heater driv‐ Sensor 1
er output After Cata‐
current > lytic Con‐
8.0 – 12.0 A verter GX7 ,
Checking”,
page 970 .
P0050 Oxygen • O2S up‐ • 2.5 s • 2 DCY – Check the
HO2S Sensors stream Oxygen
Heater Heater heater volt‐ • Continu‐ Sensor 2
Control Front age, lower ous Before Cat‐
Circuit Bank 2 range 1.92 alytic Con‐
Bank 2 Open Cir‐ – 2.21 V verter -
Sensor 1 cuit GX11- . Re‐
• O2S up‐ fer to
stream ⇒ “3.6.41
heater volt‐ Oxygen
age, upper Sensor 2
range 2.85 Before Cat‐
– 3.25 V alytic Con‐
verter
GX11 ,
Checking”,
page 978 .
P0051 Oxygen • O2S up‐ • 2.5 s • 2 DCY – Check the
HO2S Sensors stream Oxygen
Heater Heater heater volt‐ • Continu‐ Sensor 2
Control Front age < 1.92 – ous Before Cat‐
Circuit Bank 2 2.21 V alytic Con‐
Low Bank Short To verter -
2 Sensor 1 Ground GX11- . Re‐
fer to
⇒ “3.6.41
Oxygen
Sensor 2
Before Cat‐
alytic Con‐
verter
GX11 ,
Checking”,
page 978 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0052 Oxygen • O2S up‐ • EGT @ O2S • 2.5 s • 2 DCY – Check the
HO2S Sensors stream front >= -273° C Oxygen
Heater Heater heater driv‐ • Continu‐ Sensor 2
Control Front er tempera‐ • Actuator com‐ ous Before Cat‐
Circuit Bank 2 ture > 160.0 manded on alytic Con‐
High Bank Short To – 200.0° C verter -
2 Sensor 1 Battery GX11- . Re‐
Plus • Or fer to
• O2S up‐ ⇒ “3.6.41
stream Oxygen
heater driv‐ Sensor 2
er output Before Cat‐
current > alytic Con‐
8.0 –12.0 A verter
GX11 ,
Checking”,
page 978 .
P0056 Oxygen • O2S down‐ • Engine not in • 2.5 s • 2 DCY – Check the
HO2S Sensors stream start process Oxygen
Heater Heater heater volt‐ • Continu‐ Sensor 2
Control Rear age, lower ous After Cata‐
Circuit Bank 2 range 1.92 lytic Con‐
Bank 2 Open Cir‐ – 2.21 V verter -
Sensor 2 cuit GX8- . Re‐
• O2S down‐ fer to
stream ⇒ “3.6.40
heater volt‐ Oxygen
age, upper Sensor 2
range 2.85 After Cata‐
– 3.25 V lytic Con‐
verter GX8 ,
Checking”,
page 976 .
P0057 Oxygen • O2S down‐ • Engine not in • 2.5 s • 2 DCY – Check the
HO2S Sensors stream start process Oxygen
Heater Heater heater volt‐ • Continu‐ Sensor 2
Control Rear age < 1.92 – ous After Cata‐
Circuit Bank 2 2.21 V lytic Con‐
Low Bank Short To verter -
2 Sensor 2 Ground GX8- . Re‐
fer to
⇒ “3.6.40
Oxygen
Sensor 2
After Cata‐
lytic Con‐
verter GX8 ,
Checking”,
page 976 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0058 Oxygen • O2S down‐ • EGT @ O2S • 2.5 s • 2 DCY – Check the
HO2S Sensors stream front >= -273° C Oxygen
Heater Heater heater driv‐ • Continu‐ Sensor 2
Control Rear er tempera‐ • Heater com‐ ous After Cata‐
Circuit Bank 2 ture > 160.0 manded on lytic Con‐
High Bank Short To – 200.0° C • Engine not in verter -
2 Sensor 2 Battery start process GX8- . Re‐
Plus • Or fer to
• O2S down‐ ⇒ “3.6.40
stream Oxygen
heater driv‐ Sensor 2
er output After Cata‐
current > lytic Con‐
8.0 – 12.0 A verter GX8 ,
Checking”,
page 976 .
P006C Manifold • Manifold • 0.5 s • 2 DCY – Check the
MAP - Tur‐ Pressure pressure Intake Air
bocharger/ Sensor sensor sig‐ • Continu‐ Tempera‐
Super‐ Bank 1 nal failure ous ture Sensor
charger In‐ and Bank detected - G42- /
let Pres‐ 2 Electri‐ Manifold
sure Cor‐ cal Error • Manifold Absolute
relation pressure Pressure
sensor 2 Sensor -
signal fail‐ G71- . Refer
ure detec‐ to
ted ⇒ “3.6.30
Intake Air
Tempera‐
ture Sensor
G42 / Mani‐
fold Abso‐
lute Pres‐
sure Sensor
G71 ,
Checking”,
page 954 .
P0070 CAN: • AAT sensor • 2.0 s • 2 DCY – Check the
Ambient Ambient voltage Intake Air
Air Tem‐ Air Tem‐ (hardware • Continu‐ Tempera‐
perature perature values) > ous ture Sensor
Sensor Sensor 4.50 V - G42- /
Circuit "A" Short To Manifold
Battery / Absolute
Open Cir‐ Pressure
cuit Sensor -
G71- . Refer
to
⇒ “3.6.30
Intake Air
Tempera‐
ture Sensor
G42 / Mani‐
fold Abso‐
lute Pres‐
sure Sensor
G71 ,
Checking”,
page 954 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0071 Ambient • High side: • Engine off time • 0.1 s • 2 DCY – Check the
Ambient Air Tem‐ reference monitoring >= Intake Air
Air Tem‐ perature measuring 360.0 min • Once / Tempera‐
perature Sensor DCY ture Sensor
Sensor Cross • Diff. AAT @ • Stored engine - G42- /
Circuit "A" Check cold start off time signal Manifold
Range/ vs. IAT @ for actual driving Absolute
Perform‐ manifold @ cycle valid Pressure
ance cold start > Sensor -
25.0 K • Time after en‐
gine start <= G71- . Refer
• Diff. AAT @ 450.0 s to
cold start ⇒ “3.6.30
vs. IAT @ • Time after ECM Intake Air
manifold 2 wake up 1.5 – Tempera‐
@ cold start 900.0 s ture Sensor
> 25.0 K G42 / Mani‐
• AAT sensor sig‐ fold Abso‐
• Diff. AAT @ nal valid lute Pres‐
cold start sure Sensor
• And
vs. ECT @ G71 ,
cylinder • Diff. actual vs. Checking”,
block @ previous IAT page 954 .
cold start > downstream
25.0 K throttle @ cold
start < 0.8 K
• Diff. AAT @
cold start • Diff. actual vs.
vs. IAT previous IAT @
down‐ manifold @ cold
stream start < 0.8 K
throttle @
cold start > • Diff. actual vs.
25.0 K previous IAT @
manifold 2 @
• Min. cold start < 0.8 K
amount of
faulty refer‐ • Diff. actual vs.
ence meas‐ previous ECT @
urements to cylinder block @
detect de‐ cold start < 0.8 K
fective sen‐ • Diff. actual vs.
sor 4.00 [-] previous AAT @
• Or cold start < 0.8 K
• Low side: • For time >= 1.0 s
reference • Depending on
measuring mean value con‐
• Diff. IAT @ dition
manifold @ • Mean value of all
cold start temperature
vs. AAT @ sensors @ cold
cold start > start >= -256° C
25.0 K
Diff. IAT @ • Number of valid
• sensors >= 4.00
manifold 2 [-]
@ cold start
vs. AAT @ • Depending on
cold start > block heater /
25.0 K solar radiation
detection
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. ECT @ • Time after en‐
cylinder gine start >=
block @ 410.5 s
cold start
vs. AAT @ • Vehicle speed
cold start > >= 22 mph
25.0 K • For time >=
• Min. 410.0 s
amount of • Diff. actual IAT
faulty refer‐ @ downstream
ence meas‐ throttle vs. min.
urements to IAT @ down‐
detect de‐ stream throttle <
fective sen‐ 4.0 K
sor 4.0 [-]
• Diff. actual IAT
@ manifold vs.
min. IAT @
manifold < 4.0 K
• Diff. actual IAT
@ manifold 2 vs.
min. IAT @
manifold 2 < 4.0
K
• Diff. actual ECT
@ cylinder block
vs. min. ECT @
cylinder block <
4.0 K
• Diff. actual AAT
vs. min. AAT <
4.0 K
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P007B IAT Sen‐ • IAT sensor • 0.5 s • 2 DCY – Check the
Charge Air sor @ failure Charge Air
Cooler Manifold • Continu‐ Pressure
Tempera‐ Sensor ous Sensor -
ture Sen‐ Internal G31- / In‐
sor Circuit Fault take Mani‐
Range/ fold Tem‐
Perform‐ perature
ance Bank Sensor -
1 G72- . Refer
to
⇒ “3.6.10
Charge Air
Pressure
Sensor
G31 / Intake
Manifold
Tempera‐
ture Sensor
G72 ,
Checking”,
page 914 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0087 Fuel Sys‐ • Deviation • Engine speed • 2.0 s • 2 DCY – Check the
Fuel Rail/ tem Pres‐ between 512 – 8,160 Low Fuel
System sure Sen‐ reference RPM • Continu‐ Pressure
Pressure - sor, High fuel pres‐ ous Sensor -
Too Low Pressure sure set • Mass fuel flow G410- . Re‐
Bank 1 Side Out point and set point 5.0 – fer to
Of Range current fuel 1,389.0 mg/rev ⇒ “3.6.36
Low pressure > • For time after re‐ Low Fuel
2,000.10 quest for mass Pressure
kPa fuel flow set Sensor
point >= 2.0 s G410 ,
• Case: 1 Checking”,
• Fuel mass • Engine start not page 965 .
controller active
output 17.0 • Time after en‐
– 50.0 % gine start > 25.0
• High pres‐ s
sure con‐ • Engine warm-up
troller out‐ not active
put > 25 mg
• Catalyst heating
• Fuel pres‐ n.a.
sure <
34,777.60 • Full load n.a.
kPa
• Component pro‐
• Case: 2 tection n.a.
• Fuel pump • Catalyst purge
at max limit not active
• Mass fuel • Lambda control
flow set n.a.
point <
1,389.0 mg/ • Evap purge
rev functionality di‐
agnosis not ac‐
• Fuel pres‐ tive
sure <
1,500.21 • And
kPa • Choice of:
• Canister load <=
0.50 [-]
• Or
• Evap purge
valve not active
or closed
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Deviation • Engine speed • 5.0 s
tem, High lambda of 512 – 8,160
Pressure controller RPM • Continu‐
Side Ra‐ included ous
tionality adaption • Mass fuel flow
Check -15.0 – 15.0 set point 5.0 –
Low % 1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0089 Fuel • Case 1: • Engine warm-up • 2.5 s • 2 DCY – Check the
Fuel Pres‐ Pump not active Fuel Pres‐
sure Reg‐ Out Of • Actual and • Continu‐ sure Sensor
ulator 1 Range adapted I- • Catalyst heating ous - G247- .
Perform‐ High part of elec‐ not active Refer to
ance tric fuel ⇒ “3.6.27
pump con‐ • Engine no full
Fuel Pres‐
troller load
sure Sensor
(PWM sig‐ • Lambda control G247 ,
nal) > 28.0 active Checking”,
% page 948 .
• Catalyst over‐
• For time >= heating protec‐
20.0 s tion not active
• Or • Catalyst purge
• Case 2: not active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel • Case 1: • Engine warm-up
Pump not active
Out Of • Actual and
Range adapted I- • Catalyst heating
Low part of elec‐ not active
tric fuel
pump con‐ • Engine no full
troller load
(PWM sig‐ • Lambda control
nal) < -23.0 active
%
• Catalyst over‐
• For time >= heating protec‐
20.0 s tion not active
• Or • Catalyst purge
• Case 2: not active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P008A Fuel Sys‐ • Low fuel • Engine speed > • 4.9 s • 2 DCY – Check the
Low Pres‐ tem, Low pressure 512; <= 8,160 pressure in
sure Fuel Pressure value < RPM • Continu‐ the fuel sys‐
System Side Out 80.13 kPa ous tem for out
Pressure - Of Range • Electric fuel of spec con‐
Too Low Low pump active ditions be‐
• Time after en‐ fore diag‐
gine start > 12.0 nosing the
s pressure
sensor. Re‐
• Fuel pressure fer to Fuel
pump not at System Me‐
max. limit chanical
Testing in
Fuel Sys‐ • Low fuel • 0.5 s • 2 DCY ⇒ “3.1 Pre‐
tem Pres‐ pressure liminary
sure Sen‐ sensor volt‐ • Continu‐ Check”,
sor, Low age < 0.35 ous page 20 .
Pressure V
Side Out – Check the
Of Range Low Fuel
Low Pressure
Sensor -
G410- . Re‐
fer to
⇒ “3.6.36
Low Fuel
Pressure
Sensor
G410 ,
Checking”,
page 965 .
P008B Fuel Sys‐ • Low fuel • Engine speed > • 4.9 s • 2 DCY – Check the
Low Pres‐ tem, Low pressure 512; <= 8,160 pressure in
sure Fuel Pressure value RPM • Continu‐ the fuel sys‐
System Side Out 1,090.00 – ous tem for out
Pressure - Of Range 1,499.94 • Electric fuel of spec con‐
Too High High kPa pump active ditions be‐
• Time after en‐ fore diag‐
gine start > 12.0 nosing the
s pressure
sensor. Re‐
• Fuel pressure fer to Fuel
pump not at System Me‐
max. limit chanical
Testing in
Fuel Sys‐ • Low fuel • 0.5 s • 2 DCY ⇒ “3.1 Pre‐
tem Pres‐ pressure liminary
sure Sen‐ sensor volt‐ • Continu‐ Check”,
sor, Low age > 4.75 ous page 20 .
Pressure V
Side Out – Check the
Of Range Low Fuel
High Pressure
Sensor -
G410- . Re‐
fer to
⇒ “3.6.36
Low Fuel
Pressure
Sensor
G410 ,
Checking”,
page 965 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0090 Fuel Con‐ • Voltage • Engine speed 0 • 0.8 s • 2 DCY – Check the
Fuel Pres‐ trol Valve high side < RPM Fuel Pres‐
sure Reg‐ Open Cir‐ 1.87 – 2.26 • Continu‐ sure Sensor
ulator 1 cuit V • Or ous - G247- .
Control Refer to
Circuit/ • Voltage low • Fuel cut off ac‐
⇒ “3.6.27
side > 2.78 tive
Open Fuel Pres‐
– 3.33 V • Actuator com‐ sure Sensor
manded off G247 ,
Checking”,
Fuel Vol‐ • Low and • Engine speed > page 948 .
ume Reg‐ high side 600 RPM
ulator off:
Control • And
Short To • Voltage low
Ground side > 2.78 • Fuel cut off not
– 3.33 V active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0092 Fuel Con‐ • Current low • Ignition on • 0.1 s • 2 DCY – Check the
Fuel Pres‐ trol Valve side (hard‐ Fuel Pres‐
sure Reg‐ Short To ware val‐ • Or • Continu‐ sure Sensor
ulator 1 Battery ues) > 13.5 • ous - G247- .
Ignition off (dur‐
Control Plus (Low – 17.0 A ing ECM keep Refer to
Circuit Side) alive-time) ⇒ “3.6.27
High Fuel Pres‐
• And sure Sensor
G247 ,
• Actuator com‐ Checking”,
manded on page 948 .
Fuel Con‐ • Voltage • Ignition on
trol Valve high side
Short To (hardware • Or
Battery values) < • Ignition off (dur‐
Plus 1.92 – 2.21 ing ECM keep
(High V alive-time)
Side)
• And
• Actuator com‐
manded off
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0096 Intake Air • High side: • Engine off time • 0.1 s • 2 DCY – Check the
Intake Air Tempera‐ reference >= 360.0 min Intake Air
Tempera‐ ture Sen‐ measuring • Once / Tempera‐
ture Too sor • Engine off time DCY ture Sensor
High Down‐ • Diff. IAT monitoring fin‐ - G42- /
stream down‐ ished Manifold
Throttle stream Absolute
Cross throttle @ • Time after en‐
Pressure
cold start gine start <=
Check 450.0 s Sensor -
vs. IAT @ G71- . Refer
manifold @ • Time after ECM to
cold start > wake up 1.5 – ⇒ “3.6.30
25.0 K 900.0 s Intake Air
• Diff. IAT Tempera‐
• AAT sensor sig‐ ture Sensor
down‐ nal valid
stream G42 / Mani‐
throttle @ • fold Abso‐
And
cold start lute Pres‐
vs. IAT @ • Diff. actual vs. sure Sensor
manifold 2 previous IAT G71 ,
@ cold start downstream Checking”,
> 25.0 K throttle @ cold page 954 .
start < 0.8 K
• Diff. IAT
down‐ • Diff. actual vs.
stream previous IAT @
throttle @ manifold @ cold
cold start start < 0.8 K
vs. ECT @ • Diff. actual vs.
cylinder previous IAT @
block @ manifold 2 @
cold start > cold start < 0.8 K
25.0 K
• Diff. actual vs.
• Diff. IAT previous ECT @
down‐ cylinder block @
stream cold start < 0.8 K
throttle @
cold start • Diff. actual vs.
vs. AAT @ previous AAT @
cold start > cold start < 0.8 K
25.0 K
• For time >= 1.0 s
• Min.
amount of • Depending on
faulty refer‐ mean value con‐
ence meas‐ dition
urements to
detect de‐ • Mean value of all
fective sen‐ temperature
sor 4.0 [-] sensors @ cold
start >= -256° C
• Or
• Number of valid
• Low side: sensors >= 4.00
reference [-]
measuring
• Depending on
block heater /
solar radiation
detection
• Time after en‐
gine start >=
410.5 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. IAT @ • Vehicle speed
manifold @ >= 22 mph
cold start
vs. IAT • For time >= 20.0
down‐ s
stream • Diff. actual IAT
throttle @ @ downstream
cold start > throttle vs. min.
25.0 K IAT @ down‐
• Diff. IAT @ stream throttle <
manifold 2 4.0 K
@ cold start • Diff. actual IAT
vs. IAT @ manifold vs.
down‐ min. IAT @
stream manifold < 4.0 K
throttle @
cold start > • Diff. actual IAT
25.0 K @ manifold 2 vs.
min. IAT @
• Diff. ECT @ manifold 2 < 4.0
cylinder K
block @
cold start • Diff. actual ECT
vs. IAT @ cylinder block
down‐ vs. min. ECT @
stream cylinder block <
throttle @ 4.0 K
cold start >
25.0 K • Diff. actual AAT
vs. min. AAT <
• Diff. AAT @ 4.0 K
cold start
vs. IAT
down‐
stream
throttle @
cold start >
25.0 K
• Min.
amount of
faulty refer‐
ence meas‐
urements to
detect de‐
fective sen‐
sor 4.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P00A1 IAT Sen‐ • IAT sensor • Engine off time • 0.5 s • 2 DCY – Check the
Charge Air sor @ failure monitoring fin‐ Intake Air
Cooler Manifold ished • Continu‐ Tempera‐
Tempera‐ 2 Sensor ous ture Sensor
ture Sen‐ Internal - G42- /
sor Circuit Fault Manifold
Range/ Absolute
Perform‐ Pressure
ance Bank Sensor -
2 G71- . Refer
to
⇒ “3.6.30
Intake Air
Tempera‐
ture Sensor
G42 / Mani‐
fold Abso‐
lute Pres‐
sure Sensor
G71 ,
Checking”,
page 954 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P00AB Intake Air • High side: • Engine off time • 0.1 s • 2 DCY – Check the
Intake Air Tempera‐ reference >= 360.0 min Intake Air
Tempera‐ ture (IAT) measuring • Once / Tempera‐
ture Sen‐ Sensor • Engine off time DCY ture Sensor
sor 1 Cir‐ @ Mani‐ • Diff. IAT @ monitoring fin‐ - G42- /
cuit fold 2 manifold 2 ished Manifold
Range/ Cross @ cold start Absolute
Perform‐ Check vs. IAT @ • Time after en‐
Pressure
manifold @ gine start <=
ance Bank 450.0 s Sensor -
2 cold start > G71- . Refer
25.0 K • Time after ECM to
• Diff. IAT @ wake up 1.5 – ⇒ “3.6.30
manifold 2 900.0 s Intake Air
@ cold start • Tempera‐
AAT sensor sig‐ ture Sensor
vs. IAT nal valid
down‐ G42 / Mani‐
stream fold Abso‐
• And
throttle @ lute Pres‐
cold start > • Diff. actual vs. sure Sensor
25.0 K previous IAT G71 ,
downstream Checking”,
• Diff. IAT @ throttle @ cold page 954 .
manifold 2 start < 0.8 K
@ cold start
vs. ECT @ • Diff. actual vs.
cylinder previous IAT @
block @ manifold @ cold
cold start > start < 0.8 K
25.0 K • Diff. actual vs.
• Diff. IAT @ previous IAT @
manifold 2 manifold 2 @
@ cold start cold start < 0.8 K
vs. AAT @ • Diff. actual vs.
cold start > previous ECT @
25.0 K cylinder block @
• Min. cold start < 0.8 K
amount of • Diff. actual vs.
faulty refer‐ previous AAT @
ence meas‐ cold start < 0.8 K
urements to
detect de‐ • For time >= 1.0 s
fective sen‐
sor 4.0 [-] • Depending on
mean value con‐
• Or dition
• Low side: • Mean value of all
reference temperature
measuring sensors @ cold
start >= -256° C
• Diff. IAT @
manifold @ • Number of valid
cold start sensors >= 4.00
vs. IAT @ [-]
manifold 2
@ cold start • Depending on
> 25.0 K block heater /
solar radiation
detection
• Time after en‐
gine start >=
410.5 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. IAT • Vehicle speed
down‐ >= 22 mph
stream
throttle @ • For time >= 20.0
cold start s
vs. IAT @ • Diff. actual IAT
manifold 2 @ downstream
@ cold start throttle vs. min.
> 25.0 K IAT @ down‐
• Diff. ECT @ stream throttle <
cylinder 4.0 K
block @ • Diff. actual IAT
cold start @ manifold vs.
vs. IAT @ min. IAT @
manifold 2 manifold < 4.0 K
@ cold start
> 25.0 K • Diff. actual IAT
@ manifold 2 vs.
• Diff. AAT @ min. IAT @
cold start manifold 2 < 4.0
vs. IAT @ K
manifold 2
@ cold start • Diff. actual ECT
> 25.0 K @ cylinder block
vs. min. ECT @
• Min. cylinder block <
amount of 4.0 K
faulty refer‐
ence meas‐ • Diff. actual AAT
urements to vs. min. AAT <
detect de‐ 4.0 K
fective sen‐
sor 4.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0108 Pressure • Signal volt‐ • 0.5 s • 2 DCY – Check the
Manifold Sensor age > 4.80 Intake Air
Absolute Down‐ V • Continu‐ Tempera‐
Pressure/ stream ous ture Sensor
Baromet‐ Throttle - G42- /
ric Pres‐ Short To Manifold
sure Sen‐ Battery Absolute
sor Circuit Plus Pressure
High Sensor -
G71- . Refer
to
⇒ “3.6.30
Intake Air
Tempera‐
ture Sensor
G42 / Mani‐
fold Abso‐
lute Pres‐
sure Sensor
G71 ,
Checking”,
page 954 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0111 IAT Sen‐ • High side: • Engine off time • 0.1 s • 2 DCY – Check the
Intake Air sor @ reference >= 360.0 min Intake Air
Tempera‐ Manifold measuring • Once / Tempera‐
ture Sen‐ Cross • Engine off time DCY ture Sensor
sor 1 Cir‐ Check • Diff. IAT @ monitoring fin‐ - G42- /
cuit manifold 2 ished Manifold
Range/ @ cold start Absolute
Perform‐ vs. IAT @ • Time after en‐
Pressure
manifold @ gine start <=
ance Bank 450.0 s Sensor -
1 cold start > G71- . Refer
25.0 K • Time after ECM to
• Diff. IAT @ wake up 1.5 – ⇒ “3.6.30
manifold 2 900.0 s Intake Air
@ cold start • Tempera‐
AAT sensor sig‐ ture Sensor
vs. IAT nal valid
down‐ G42 / Mani‐
stream fold Abso‐
• And
throttle @ lute Pres‐
cold start > • Diff. actual vs. sure Sensor
25.0 K previous IAT G71 ,
downstream Checking”,
• Diff. IAT @ throttle @ cold page 954 .
manifold 2 start < 0.8 K
@ cold start
vs. ECT @ • Diff. actual vs.
cylinder previous IAT @
block @ manifold @ cold
cold start > start < 0.8 K
25.0 K • Diff. actual vs.
• Diff. IAT @ previous IAT @
manifold 2 manifold 2 @
@ cold start cold start < 0.8 K
vs. AAT @ • Diff. actual vs.
cold start > previous ECT @
25.0 K cylinder block @
• Min. cold start < 0.8 K
amount of • Diff. actual vs.
faulty refer‐ previous AAT @
ence meas‐ cold start < 0.8 K
urements to
detect de‐ • For time >= 1.0 s
fective sen‐
sor 4.0 [-] • Depending on
mean value con‐
• Or dition
• Low side: • Mean value of all
reference temperature
measuring sensors @ cold
start >= -256° C
• Diff. IAT @
manifold @ • Number of valid
cold start sensors >= 4.00
vs. IAT @ [-]
manifold 2
@ cold start • Depending on
> 25.0 K block heater /
solar radiation
detection
• Time after en‐
gine start >=
410.5 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. IAT • Vehicle speed
down‐ >= 22 mph
stream
throttle @ • For time >= 20.0
cold start s
vs. IAT @ • Diff. actual IAT
manifold 2 @ downstream
@ cold start throttle vs. min.
> 25.0 K IAT @ down‐
• Diff. ECT @ stream throttle <
cylinder 4.0 K
block @ • Diff. actual IAT
cold start @ manifold vs.
vs. IAT @ min. IAT @
manifold 2 manifold < 4.0 K
@ cold start
> 25.0 K • Diff. actual IAT
@ manifold 2 vs.
• Diff. AAT @ min. IAT @
cold start manifold 2 < 4.0
vs. IAT @ K
manifold 2
@ cold start • Diff. actual ECT
> 25.0 K @ cylinder block
vs. min. ECT @
• Min. cylinder block <
amount of 4.0 K
faulty refer‐
ence meas‐ • Diff. actual AAT
urements to vs. min. AAT <
detect de‐ 4.0 K
fective sen‐
sor 4.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0113 Intake Air • IAT sensor • 0.5 s • 2 DCY – Check the
Intake Air Tempera‐ voltage > Intake Air
Tempera‐ ture Sen‐ 4.50 V • Continu‐ Tempera‐
ture Sen‐ sor Open ous ture Sensor
sor 1 Cir‐ Circuit - G42- /
cuit High Manifold
Bank 1 Absolute
Pressure
Sensor -
G71- . Refer
to
⇒ “3.6.30
Intake Air
Tempera‐
ture Sensor
G42 / Mani‐
fold Abso‐
lute Pres‐
sure Sensor
G71 ,
Checking”,
page 954 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0116 Engine • Difference • ECT @ cylinder • 1.0 s • 2 DCY – Check the
Engine Coolant between block > 39° C Engine
Coolant Tempera‐ maximum • Once / Coolant
Tempera‐ ture Sen‐ and mini‐ • IAT @ throttle DCY Tempera‐
ture Sen‐ sor @ mum tem‐ -48 – 143° C ture Sensor
sor 1 Cir‐ Cylinder perature of • Depending on - G62- . Re‐
cuit Block Ra‐ ECT @ cyl‐ thermostat con‐ fer to
Range/ tionality inder block trol: ⇒ “3.6.17
Perform‐ Check < 2° C Engine
ance High • ECT @ cylinder Coolant
block <= n.a.° C Tempera‐
ture Sensor
• Or G62 ,
Checking”,
• ECT @ cylinder page 928 .
block >= n.a.° C
• Engine n.a.
• And
• Engine part load
• Or
• Engine full load
• Engine speed >
1,500 RPM
• Vehicle speed
>= 12 mph
• Engine load >
0.00 %
• For time >= 20.0
– 43.0 s
• Engine idle vehi‐
cle speed < 93
mph
• Or
• Fuel cut off ac‐
tive
• Or
• Engine stop
• For time >= 20.0
– 43.0 s
• Time after en‐
gine start >
100.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0117 Engine • ECT sensor • 0.5 s • 2 DCY – Check the
Engine Coolant voltage @ Engine
Coolant Tempera‐ cylinder • Continu‐ Coolant
Tempera‐ ture Sen‐ block < 0.30 ous Tempera‐
ture Sen‐ sor @ V ture Sensor
sor 1 Cir‐ Cylinder - G62- . Re‐
cuit Low Block fer to
Short To ⇒ “3.6.17
Ground Engine
Coolant
Tempera‐
ture Sensor
G62 ,
Checking”,
page 928 .
P0118 Engine • ECT sensor • IAT @ throttle • 0.5 s • 2 DCY – Check the
Engine Coolant voltage @ >= -33° C Engine
Coolant Tempera‐ cylinder • Continu‐ Coolant
Tempera‐ ture Sen‐ block > 4.90 • Time after en‐ ous Tempera‐
ture Sen‐ sor @ V gine start > 60.0 ture Sensor
sor 1 Cir‐ Cylinder s - G62- . Re‐
cuit High Block fer to
Short To ⇒ “3.6.17
Battery / Engine
Open Cir‐ Coolant
cuit Tempera‐
ture Sensor
G62 ,
Checking”,
page 928 .
P0121 Throttle • Normalised • Throttle adapta‐ • 0.01 s • 2 DCY – Check the
Throttle/ Position difference tion (@ initial Throttle
Pedal Po‐ Sensor 1 between start or after de‐ • Continu‐ Valve Con‐
sition Sen‐ Rationali‐ measured tection of throttle ous trol Module
sor/Switch ty Check and mod‐ exchange or - GX3- . Re‐
"A" Circuit eled value checksum error) fer to
Range/ of mass air not active ⇒ “3.6.45
Perform‐ flow from Throttle
ance TPS 1 >= Valve Con‐
1.00 [-] trol Module
GX3 ,
• Or Checking”,
• Relative page 987 .
mass air
flow integral
from TPS 1
> 60.0 [-]
• Difference • 0.3 s
between
TPS 1 and • Continu‐
TPS 2 > ous
5.799° TPS
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0122 Throttle • Throttle po‐ • 0.2 s • 2 DCY – Check the
Throttle/ Position sition sen‐ Throttle
Pedal Po‐ Sensor 1 sor 1 volt‐ • Continu‐ Valve Con‐
sition Sen‐ Short To age < 0.17 ous trol Module
sor/Switch Ground V - GX3- . Re‐
"A" Circuit fer to
Low ⇒ “3.6.45
Throttle
Valve Con‐
trol Module
GX3 ,
Checking”,
page 987 .
P0123 Throttle • Throttle po‐ • 0.2 s • 2 DCY – Check the
Throttle/ Position sition sen‐ Throttle
Pedal Po‐ Sensor 1 sor 1 volt‐ • Continu‐ Valve Con‐
sition Sen‐ Short To age > 4.60 ous trol Module
sor/Switch Battery V - GX3- . Re‐
"A" Circuit Plus fer to
High ⇒ “3.6.45
Throttle
Valve Con‐
trol Module
GX3 ,
Checking”,
page 987 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P012B Pressure • Diff. pres‐ • Engine @ driv‐ • 3.0 s • 2 DCY – Check the
Turbo‐ Sensor sure down‐ ing cycle not Intake Air
charger/ Down‐ stream started the first • Continu‐ Tempera‐
Super‐ stream throttle vs. time ous ture Sensor
charger In‐ Throttle manifold - G42- /
let Pres‐ Engine pressure >= • Vehicle speed < Manifold
sure Sen‐ Off: 7.0 kPa 1 mph Absolute
sor "A" Cir‐ Cross Pressure
cuit Check • Diff. pres‐ Sensor -
Range/ sure down‐ G71- . Refer
Perform‐ stream to
ance throttle vs. ⇒ “3.6.30
manifold Intake Air
pressure 2 Tempera‐
>= 7.0 kPa ture Sensor
• Or G42 / Mani‐
fold Abso‐
• Diff. pres‐ lute Pres‐
sure down‐ sure Sensor
stream G71 ,
throttle vs. Checking”,
manifold page 954 .
pressure >=
7.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(MAP 2 and
BARO) vs.
deviation
MAP to
mean value
(MAP 2 and
BARO) > 0
kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.0 kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(MAP 2 and
MAP) vs.
deviation
BARO to
mean value
(MAP 2 and
MAP) > 0
kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.0 kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(BARO and
MAP) vs.
deviation
MAP 2 to
mean value
(BARO and
MAP) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Pressure • Case 1: • Modeled pres‐
Sensor sure quotient
Down‐ • Diff. pres‐ (downstream /
stream sure down‐ upstream throt‐
Throttle stream tle) 0.30 – 0.45
Idle throttle vs. [-]
Speed: manifold
Cross pressure 2
Check >= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
< 8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Pressure • Diff. pres‐ • Engine stopped
Sensor sure down‐
Down‐ stream
stream throttle vs.
Throttle manifold
ECM pressure >=
Keep 7.0 kPa
Alive-
Time: • Diff. pres‐
Cross sure down‐
Check stream
throttle vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐ • Vehicle speed <
tion pres‐ 1 mph
sure down‐
stream • ECM keep alive
throttle to time > 10.0 s
mean value • Time after en‐
(MAP 2 and gine stop >= 4.0
BARO) vs. s
deviation
MAP to • Barometric
mean value pressure 55.0 –
(MAP 2 and 110.0 kPa
BARO) > 0
kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.0 kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(MAP 2 and
MAP) vs.
deviation
BARO to
mean value
(MAP 2 and
MAP) > 0
kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.0 kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(BARO and
MAP) vs.
deviation
MAP 2 to
mean value
(BARO and
MAP) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Pressure • Case 1: • Engine running
Sensor
Down‐ • Diff. pres‐ • Modeled pres‐
stream sure down‐ sure quotient
Throttle stream (downstream /
Engine throtte vs. upstream throt‐
Running manifold tle) > 0.45; <=
Non pressure 2 0.80 [-]
Charged >= 12.0 –
Engine: 27.0 kPa
Cross • Diff. pres‐
Check sure down‐
stream
throtte vs.
manifold
pressure >=
12.0 – 27.0
kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
< 12.0 –
27.0 kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Pressure • Case 1: • Fuel cut off ac‐ • 3.0 s
Sensor tive
Down‐ • Diff. pres‐
stream sure down‐
Throttle stream
Fuel Cut throttle vs.
Off: manifold
Cross pressure 2
Check >= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
< 8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐ • Modeled pres‐
tion pres‐ sure quotient
sure down‐ (downstream /
stream upstream throt‐
throttle to tle) 0.25 – 0.30
mean value [-]
(pressure
down‐ • For time >= 5.0 s
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
P0131 Oxygen • O2S sensor • Engine running • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage < Oxygen
Circuit Front 0.15 V • Continu‐ Sensor 1
Low Volt‐ Short To ous Before Cat‐
age Bank Ground alytic Con‐
1 Sensor 1 verter -
GX10- . Re‐
fer to
⇒ “3.6.39
Oxygen
Sensor 1
Before Cat‐
alytic Con‐
verter
GX10 ,
Checking”,
page 972 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0132 Oxygen • O2S sensor • Engine running • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage > Oxygen
Circuit Front 5.20 – 5.35 • Continu‐ Sensor 1
High Volt‐ Short To V ous Before Cat‐
age Bank Battery alytic Con‐
1 Sensor 1 Plus verter -
GX10- . Re‐
fer to
⇒ “3.6.39
Oxygen
Sensor 1
Before Cat‐
alytic Con‐
verter
GX10 ,
Checking”,
page 972 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0133 Oxygen • Dynamic • General condi‐ • 4.2 s • 2 DCY – Check the
O2 Sensor Sensors path: tions: Oxygen
Circuit Front Re‐ • Continu‐ Sensor 1
Slow Re‐ sponse • Lambda • Injection mode ous Before Cat‐
sponse Check value vs. change (DFI/ alytic Con‐
Bank 1 modeled MFI) not active verter -
Sensor 1 lambda val‐ GX10- . Re‐
ue >= 0.90 • ECT @ cylinder
fer to
[-] block >= 40° C
⇒ “3.6.39
• Or • Vehicle speed > Oxygen
0 mph Sensor 1
• Ratio of Before Cat‐
failed diag‐ • Integrated air alytic Con‐
nostic cycle mass after gear verter
> n.a. [-] change > 0.0 g GX10 ,
Checking”,
• Air mass , lower page 972 .
range >= 64.01 –
114.01 mg/rev
• Air mass , upper
range <= 465.01
– 565.01 mg/rev
• Counter of inte‐
grated mass for
fuel in oil <
255.00 [-]
• Counter of inte‐
grated mass for
fuel in oil <
255.00 [-]
• Lambda sensor
dynamic error
not active
• And
• Time after en‐
gine start >= 0.0
s
• Or
• Integrated air
mass per cylin‐
der >= 0.750 kg
• Depending on
canister and cat‐
alyst purge:
• Evap purge n.a.
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• canister load
calculation n.a.
• Or
• Evap purge n.a.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Canister load <=
n.a. [-]
• And
• Case 1:
• O2S front n.a.
• Lambda stimu‐
lation n.a.
• Upper limit of
lambda control‐
ler output n.a.
• Lower limit of
lambda control‐
ler output n.a.
• Engine speed
n.a. RPM
• Air mass n.a.
mg/rev
• MAF > n.a. kg/h
• Catalyst purge
n.a.
• And
• Depending on
limited dynamic
conditions:
• Integrated air
mass < n.a. g
• Dynamic engine
speed < n.a. g
• Dynamic air
mass < n.a. mg/
rev
• Dynamic lamb‐
da < n.a. %
• Or
• Dynamic engine
speed < n.a.
RPM
• Diff. actual en‐
gine load vs. fil‐
tered engine
load in limited
dynamic condi‐
tions, lower
range >= n.a. kg/
h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. actual en‐
gine load vs. fil‐
tered engine
load in limited
dynamic condi‐
tions, upper
range <= n.a. kg/
h
• Dynamic torque
< n.a. [-]
• Case 2:
• Lambda set val‐
ue adjustment
for conditioning
and measuring
active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Delay path: • General condi‐ • 6.0 s
tions:
• Lambda de‐
lay value vs. • Air mass , lower
modeled range >= 80.01 –
lambda val‐ 130.01 mg/rev
ue > 0.90 [-]
• Air mass , upper
range <= 450.01
– 550.00 mg/rev
• Integrated air
mass per cylin‐
der >= 0.490 –
0.950 kg
• Vehicle speed
>= 0 mph
• Time after en‐
gine start >= 0.0
s
• Injection mode
change (DFI/
MFI) not active
• Counter of inte‐
grated mass for
fuel in oil < 35.00
[-]
• Engine speed
960 – 3,008
RPM
• MAF (intake air
rate) 5.0 – 235.0
kg/h
• Vehicle speed
>= 0 mph
• Lambda sensor
dynamic error
not active
• And
• Depending on
dynamic condi‐
tions:
• Dynamic engine
speed < 512
RPM
• Dynamic torque
< 130.0 Nm
• Dynamic MAF <
80.0 kg/h
• For time >= 0.6 s
• And
• Depending on
canister and cat‐
alyst purge:
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge n.a. • Continu‐
ous
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Canister load
calculation n.a.
• Or
• Evap purge n.a.
• Canister load <=
n.a. [-]
P0135 Oxygen • O2S ceram‐ • Heater com‐ • 20.0 s • 2 DCY – Check the
O2 Sensor Sensors ic tempera‐ manded off Oxygen
Heater Cir‐ Heater ture < 680° • Continu‐ Sensor 1
cuit Bank 1 Front C • For time >= 17.0 ous Before Cat‐
Sensor 1 Function‐ s alytic Con‐
al Check • And verter -
GX10- . Re‐
• O2S ceramic fer to
temperature < ⇒ “3.6.39
680° C Oxygen
Sensor 1
• Or Before Cat‐
alytic Con‐
• Case 1: verter
• Integrated sub‐ GX10 ,
mitted heat en‐ Checking”,
ergy >= 1,000.0 page 972 .
J
• Case 2:
• Engine stop time
signal n.a.
• Engine n.a.
• For time >= n.a.
min
P0137 Oxygen • O2S sensor • O2S heater ac‐ • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage < tive Oxygen
Circuit Rear 0.15 V • Continu‐ Sensor 1
Low Volt‐ Short To ous After Cata‐
age Bank Ground lytic Con‐
1 Sensor 2 verter -
GX7- . Re‐
fer to
⇒ “3.6.38
Oxygen
Sensor 1
After Cata‐
lytic Con‐
verter GX7 ,
Checking”,
page 970 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0138 Oxygen • O2S sensor • O2S heater ac‐ • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage > tive Oxygen
Circuit Rear 5.2 – 5.35 V • Continu‐ Sensor 1
High Volt‐ Short To ous After Cata‐
age Bank Battery lytic Con‐
1 Sensor 2 verter -
GX7- . Re‐
fer to
⇒ “3.6.38
Oxygen
Sensor 1
After Cata‐
lytic Con‐
verter GX7 ,
Checking”,
page 970 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P013A Oxygen • Gradient • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors sensor volt‐ tions: (FTP75: Oxygen
Slow Re‐ Rear age < 800.0 50.0) s Sensor 1
sponse - Close mV/s • Intrusive lambda After Cata‐
Rich to The Gap ramp request • Once / lytic Con‐
Lean Bank Condi‐ not active DCY verter -
1 Sensor 2 tions: Re‐ • Internal resist‐ GX7- . Re‐
sponse ance O2S rear < fer to
Check 3,000.0 Ω ⇒ “3.6.38
Oxygen
• Counter of inte‐ Sensor 1
grated mass for After Cata‐
fuel in oil < 35.00 lytic Con‐
[-] verter GX7 ,
Checking”,
• Catalyst monitor page 970 .
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 0 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
1,000 Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P013B Oxygen • Gradient • General condi‐ • 400.0 s • 2 DCY – Check the
O2 Sensor Sensors sensor volt‐ tions: Oxygen
Slow Re‐ Rear Re‐ age < 800.0 • Once / Sensor 1
sponse - sponse mV/s • Intrusive lambda DCY After Cata‐
Lean to Check ramp request lytic Con‐
Rich Bank not active verter -
1 Sensor 2 • Internal resist‐ GX7- . Re‐
ance O2S rear < fer to
3,000.0 Ω ⇒ “3.6.38
Oxygen
• Counter of inte‐ Sensor 1
grated mass for After Cata‐
fuel in oil < 35.00 lytic Con‐
[-] verter GX7 ,
Checking”,
• Catalyst monitor page 970 .
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 0 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
1,000 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P013C Oxygen • Gradient • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors sensor volt‐ tions: (FTP75: Oxygen
Slow Re‐ Rear age < 800.0 50.0) s Sensor 2
sponse - Bank 2 mV/s • Intrusive lambda After Cata‐
Rich to Close ramp request • Once / lytic Con‐
Lean Bank The Gap not active DCY verter -
2 Sensor 2 Condi‐ • Internal resist‐ GX8- . Re‐
tions: Re‐ ance O2S rear < fer to
sponse 3,000.0 Ω ⇒ “3.6.40
Check Oxygen
• Counter of inte‐ Sensor 2
grated mass for After Cata‐
fuel in oil < 35.00 lytic Con‐
[-] verter GX8 ,
Checking”,
• Catalyst monitor page 976 .
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 0 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
1,000 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P013D Oxygen • Gradient • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors sensor volt‐ tions: (FTP75: Oxygen
Slow Re‐ Rear age < 800.0 50.0) s Sensor 2
sponse - Bank 2 mV/s • Intrusive lambda After Cata‐
Lean to Re‐ ramp request • Once / lytic Con‐
Rich Bank sponse not active DCY verter -
2 Sensor 2 Check • Internal resist‐ GX8- . Re‐
ance O2S rear < fer to
3,000.0 Ohm ⇒ “3.6.40
Oxygen
• Counter of inte‐ Sensor 2
grated mass for After Cata‐
fuel in oil < 35.00 lytic Con‐
[-] verter GX8 ,
Checking”,
• Catalyst monitor page 976 .
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 0 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
1,000 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P013E Oxygen • Sensor sig‐ • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors nal delay tions: (FTP75: Oxygen
Delayed Rear time > 0.8 s 50.0) s Sensor 1
Response Bank 2 • Intrusive lambda After Cata‐
- Rich to Delayed ramp request • Once / lytic Con‐
Lean Bank Re‐ not active DCY verter -
1 Sensor 2 sponse • Internal resist‐ GX7- . Re‐
Monitor‐ ance O2S rear < fer to
ing, De‐ 3,000.0 Ω ⇒ “3.6.38
lay Meas‐ Oxygen
urement • Counter of inte‐ Sensor 1
grated mass for After Cata‐
fuel in oil < 35.00 lytic Con‐
[-] verter GX7 ,
Checking”,
• Catalyst monitor page 970 .
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 0 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
1,000 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P013F Oxygen • Sensor sig‐ • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors nal delay tions: (FTP75: Oxygen
Delayed Rear time > 0.8 s 50.0) s Sensor 1
Response Bank 2 • Intrusive lambda After Cata‐
- Lean to Delayed ramp request • Once / lytic Con‐
Rich Bank Re‐ not active DCY verter -
1 Sensor 2 sponse • Internal resist‐ GX7- . Re‐
Monitor‐ ance O2S rear < fer to
ing, De‐ 3,000.0 Ω ⇒ “3.6.38
lay Meas‐ Oxygen
urement • Counter of inte‐ Sensor 1
grated mass for After Cata‐
fuel in oil < 35.00 lytic Con‐
[-] verter GX7 ,
Checking”,
• Catalyst monitor page 970 .
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 0 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
1,000 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0141 Oxygen • O2S inter‐ • Heater com‐ • 20.0 s • 2 DCY – Check the
O2 Sensor Sensors nal resist‐ manded off Oxygen
Heater Cir‐ Heater ance (bina‐ • Continu‐ Sensor 1
cuit Bank 1 Rear Out ry) >= • For time >= 30.0 ous After Cata‐
Sensor 2 Of Range 1,000.0 – s lytic Con‐
High 23,000.0 Ω • And verter -
GX7- . Re‐
• O2S internal re‐ fer to
sistance (binary) ⇒ “3.6.38
> 1,000.0 Ω Oxygen
Sensor 1
• Or After Cata‐
lytic Con‐
• Case 1: verter GX7 ,
• Integrated sub‐ Checking”,
mitted heat en‐ page 970 .
ergy >= n.a. J
• Case 2:
• Engine stop time
signal n.a.
• Engine n.a.
• For time >= n.a.
min
P0149 Injection • Boost volt‐ • Engine running • 3.6 s • 2 DCY – Check the
Fuel Tim‐ Valves age < 30.0 >= 0.3 s Fuel Injec‐
ing Error Supply V • Continu‐ tors . Refer
Voltage ous to
Out Of • Boost volt‐ ⇒ “3.6.24
Range age <= 30.0 Fuel Injec‐
Low V tors, Check‐
ing”,
Injection • Boost volt‐ page 942 .
Valves age > 75.0
Supply V
Voltage
Out Of
Range
High
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P014A Oxygen • Sensor sig‐ • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors nal delay tions: (FTP75: Oxygen
Delayed Rear time > 0.8 s 50.0) s Sensor 2
Response Bank 2 • Intrusive lambda After Cata‐
- Rich to Delayed ramp request • Once / lytic Con‐
Lean Bank Re‐ not active DCY verter -
2 Sensor 2 sponse • Internal resist‐ GX8- . Re‐
Monitor‐ ance O2S rear < fer to
ing, De‐ 3,000.0 Ω ⇒ “3.6.40
lay Meas‐ Oxygen
urement • Counter of inte‐ Sensor 2
grated mass for After Cata‐
fuel in oil < 35.00 lytic Con‐
[-] verter GX8 ,
Checking”,
• Catalyst monitor page 976 .
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 0 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
1,000 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P014B Oxygen • Sensor sig‐ • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors nal delay tions: (FTP75: Oxygen
Delayed Rear time > 0.8 s 50.0) s Sensor 2
Response Bank 2 • Intrusive lambda After Cata‐
- Lean to Delayed ramp request • Once / lytic Con‐
Rich Bank Re‐ not active DCY verter -
2 Sensor 2 sponse • Internal resist‐ GX8- . Re‐
Monitor‐ ance O2S rear < fer to
ing, De‐ 3,000.0 Ω ⇒ “3.6.40
lay Meas‐ Oxygen
urement • Counter of inte‐ Sensor 2
grated mass for After Cata‐
fuel in oil < 35.00 lytic Con‐
[-] verter GX8 ,
Checking”,
• Catalyst monitor page 976 .
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 0 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
1,000 Ω
P0151 Oxygen • O2S sensor • Engine running • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage < Oxygen
Circuit Front 0.15 V • Continu‐ Sensor 2
Low Volt‐ Bank 2 ous Before Cat‐
age Bank Short To alytic Con‐
2 Sensor 1 Ground verter -
GX11- . Re‐
fer to
⇒ “3.6.41
Oxygen
Sensor 2
Before Cat‐
alytic Con‐
verter
GX11 ,
Checking”,
page 978 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0152 Oxygen • O2S sensor • Engine running • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage > Oxygen
Circuit Front 5.20 – 5.35 • Continu‐ Sensor 2
High Volt‐ Bank 2 V ous Before Cat‐
age Bank Short To alytic Con‐
2 Sensor 1 Battery verter -
Plus GX11- . Re‐
fer to
⇒ “3.6.41
Oxygen
Sensor 2
Before Cat‐
alytic Con‐
verter
GX11 ,
Checking”,
page 978 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0153 Oxygen • Dynamic • General condi‐ • 4.2 s • 2 DCY – Check the
O2 Sensor Sensors path: tions: Oxygen
Circuit Front • Continu‐ Sensor 2
Slow Re‐ Bank 2 • Lambda • Injection mode ous Before Cat‐
sponse Re‐ value vs. change (DFI/ alytic Con‐
Bank 2 sponse modeled MFI) not active verter -
Sensor 1 Check lambda val‐ GX11- . Re‐
ue >= 0.90 • ECT @ cylinder
fer to
[-] block >= 40° C
⇒ “3.6.41
• Or • Vehicle speed > Oxygen
0 mph Sensor 2
• Ratio of Before Cat‐
failed diag‐ • Integrated air alytic Con‐
nostic cycle mass after gear verter
> n.a. [-] change > 0.0 g GX11 ,
Checking”,
• Air mass , lower page 978 .
range >= 64.01 –
114.01 mg/rev
• Air mass , upper
range <= 465.01
– 565.01 mg/rev
• Counter of inte‐
grated mass for
fuel in oil < 255.0
[-]
• Lambda sensor
dynamic error
not active
• And
• Time after en‐
gine start >= 0.0
s
• Or
• Integrated air
mass per cylin‐
der >= 0.750 kg
• Depending on
canister and cat‐
alyst purge:
• Evap purge n.a.
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Canister load
calculation n.a.
• Or
• Evap purge n.a.
• Canister load <=
n.a. [-]
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Case 1:
• O2S front n.a.
• Lambda stimu‐
lation n.a.
• Upper limit of
lambda control‐
ler output n.a.
• Lower limit of
lambda control‐
ler output n.a.
• Engine speed
n.a. RPM
• Air mass n.a.
mg/rev
• MAF > n.a. kg/h
• Catalyst purge
n.a.
• And
• Depending on
limited dynamic
conditions:
• Integrated air
mass < n.a. g
• Dynamic engine
speed < n.a. g
• Dynamic air
mass < n.a. mg/
rev
• Dynamic lamb‐
da < n.a. %
• Or
• Dynamic engine
speed < n.a.
RPM
• Diff. actual en‐
gine load vs. fil‐
tered engine
load in limited
dynamic condi‐
tions, lower
range >= n.a. kg/
h
• Diff. actual en‐
gine load vs. fil‐
tered engine
load in limited
dynamic condi‐
tions, upper
range <= n.a. kg/
h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Dynamic torque
< n.a.[-]
• Case 2:
• Lambda set val‐
ue adjustment
for conditioning
and measuring
active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Delay Path: • General condi‐ • 6.0 s
tions:
• Lambda de‐
lay value vs. • Air mass , lower
modeled range >= 80.01 –
lambda val‐ 130.01 mg/rev
ue > 0.90 [-]
• Air mass , upper
range <= 450.01
– 550.00 mg/rev
• Integrated air
mass per cylin‐
der >= 0.490 –
0.950 kg
• Vehicle speed
>= 0 mph
• Time after en‐
gine start >= 0.0
s
• Injection mode
change (DFI/
MFI) not active
• Counter of inte‐
grated mass for
fuel in oil < 35.0
[-]
• Engine speed
960 – 3,008
RPM
• MAF (intake air
rate) 5.0 – 235.0
kg/h
• Vehicle speed
>= 0 mph
• Lambda sensor
dynamic error
not active
• And
• Depending on
dynamic condi‐
tions:
• Dynamic engine
speed < 512
RPM
• Dynamic torque
< 130.0 Nm
• Dynamic MAF <
80.0 kg/h
• For time >= 0.6 s
• And
• Depending on
canister and cat‐
alyst purge:
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge n.a. • Continu‐
ous
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Canister load
calculation n.a.
• Or
• Evap purge n.a.
• Canister load <=
n.a. [-]
P0157 Oxygen • O2S sensor • O2S heater ac‐ • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage < tive Oxygen
Circuit Rear 0.15 V • Continu‐ Sensor 2
Low Volt‐ Bank 2 ous After Cata‐
age Bank Short To lytic Con‐
2 Sensor 2 Ground verter -
GX8- . Re‐
fer to
⇒ “3.6.40
Oxygen
Sensor 2
After Cata‐
lytic Con‐
verter GX8 ,
Checking”,
page 976 .
P0158 Oxygen • O2S sensor • O2S heater ac‐ • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage > tive Oxygen
Circuit Rear 5.2 – 5.35 V • Continu‐ Sensor 2
High Volt‐ Bank 2 ous After Cata‐
age Bank Short To lytic Con‐
2 Sensor 2 Battery verter -
GX8- . Re‐
fer to
⇒ “3.6.40
Oxygen
Sensor 2
After Cata‐
lytic Con‐
verter GX8 ,
Checking”,
page 976 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0160 Oxygen • Internal re‐ • 2.5 s • 2 DCY – Check the
O2 Sensor Sensors sistance of Oxygen
Circuit No Rear O2S (bina‐ • Continu‐ Sensor 2
Activity Bank 2 ry) > ous After Cata‐
Detected Open Cir‐ 23,000.0 Ω lytic Con‐
Bank 2 cuit verter -
Sensor 2 GX8- . Re‐
fer to
⇒ “3.6.40
Oxygen
Sensor 2
After Cata‐
lytic Con‐
verter GX8 ,
Checking”,
page 976 .
P0161 Oxygen • O2S inter‐ • Heater com‐ • 20.0 s • 2 DCY – Check the
O2 Sensor Sensors nal resist‐ manded off Oxygen
Heater Cir‐ Heater ance (bina‐ • Continu‐ Sensor 2
cuit Bank 2 Rear 2 ry) >= • For time >= 30.0 ous After Cata‐
Sensor 2 Out Of 1,000.0 – s lytic Con‐
Range 23,000.0 Ω • And verter -
High GX8- . Re‐
• O2S internal re‐ fer to
sistance (binary) ⇒ “3.6.40
> 1,000.0 Ω Oxygen
Sensor 2
• Or After Cata‐
lytic Con‐
• Case 1: verter GX8 ,
• Integrated sub‐ Checking”,
mitted heat en‐ page 976 .
ergy >= n.a. J
• Case 2:
• Engine stop time
signal n.a.
• Engine n.a.
• For time >= n.a.
min
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0171 Fuel Sys‐ • Lambda • Lambda control • 180.0 s • 2 DCY – Check the
System tem Too controller closed loop Fuel Deliv‐
Too Lean Lean output > • Continu‐ ery Unit -
Bank 1 37.0 % • Mass air flow > ous GX1- . Re‐
76.0 mg/rev fer to
• Engine speed > ⇒ “3.6.23
544 RPM Fuel Deliv‐
ery Unit
• ECT @ cylinder GX1 ,
block > 70° C Checking”,
page 940 .
• IAT at intake
manifold > -11° – Check the
C pressure in
the fuel sys‐
• AAT > -48° C tem for out
• Ethanol value of spec con‐
n.a. ditions be‐
fore diag‐
• And nosing the
pressure
• Evap purge sensor. Re‐
valve closed fer to Fuel
• Or System Me‐
chanical
• Canister load <= Testing in
2.00 [-] ⇒ “3.1 Pre‐
liminary
• Evap purge flow Check”,
at max. value page 20 .
• Or
– Check the
• Depending on Fuel Injec‐
canister purge tors . Refer
min: to
⇒ “3.6.24
• Lower limit of Fuel Injec‐
lambda control‐ tors, Check‐
ler output n.a. ing”,
page 942 .
• Or
• Upper limit of – Check the
lambda control‐ intake sys‐
ler output n.a. tem visually
for leaks
• And (false air).
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0172 Fuel Sys‐ • Lambda • Lambda control • 180.0 s • 2 DCY – Check the
System tem Too controller closed loop Fuel Deliv‐
Too Rich Rich output < • Continu‐ ery Unit -
Bank 1 -37.0 % • Mass air flow > ous GX1- . Re‐
76.0 mg/rev fer to
• Engine speed > ⇒ “3.6.23
544 RPM Fuel Deliv‐
ery Unit
• ECT @ cylinder GX1 ,
block > 70° C Checking”,
page 940 .
• IAT at intake
manifold > -11° – Check the
C pressure in
the fuel sys‐
• AAT > -48° C tem for out
• Ethanol value of spec con‐
n.a. ditions be‐
fore diag‐
• Oil dilution not nosing the
detected pressure
sensor. Re‐
• And fer to Fuel
• Evap purge System Me‐
valve closed chanical
Testing in
• Or ⇒ “3.1 Pre‐
liminary
• Canister load <= Check”,
2.00 [-] page 20 .
• Evap purge flow
at max. value – Check the
Fuel Injec‐
• Or tors . Refer
to
• Depending on ⇒ “3.6.24
canister purge Fuel Injec‐
min: tors, Check‐
ing”,
• Lower limit of page 942 .
lambda control‐
ler output n.a. – Check the
• Or Oxygen
Sensor 1
• Upper limit of Before Cat‐
lambda control‐ alytic Con‐
ler output n.a. verter -
GX10- . Re‐
• And fer to
• Evap purge flow ⇒ “3.6.39
at min. value Oxygen
Sensor 1
Before Cat‐
alytic Con‐
verter
GX10 ,
Checking”,
page 972 .
– Check the
intake sys‐
tem visually
for leaks
(false air).
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0174 Fuel Sys‐ • Lambda • Lambda control • 180.0 s • 2 DCY – Check the
System tem Too controller closed loop Fuel Deliv‐
Too Lean Lean output > • Continu‐ ery Unit -
Bank 2 37.0 % • Mass air flow > ous GX1- . Re‐
76.0 mg/rev fer to
• Engine speed > ⇒ “3.6.23
544 RPM Fuel Deliv‐
ery Unit
• ECT @ cylinder GX1 ,
block > 70° C Checking”,
page 940 .
• IAT at intake
manifold > -11° – Check the
C pressure in
the fuel sys‐
• AAT > -48° C tem for out
• Ethanol value of spec con‐
n.a. ditions be‐
fore diag‐
• And nosing the
pressure
• Evap purge sensor. Re‐
valve closed fer to Fuel
• Or System Me‐
chanical
• Canister load <= Testing in
2.00 [-] ⇒ “3.1 Pre‐
liminary
• Evap purge flow Check”,
at max. value page 20 .
• Or
– Check the
• Depending on Oxygen
canister purge Sensor 2
min: Before Cat‐
alytic Con‐
• Lower limit of verter -
lambda control‐ GX11- . Re‐
ler output n.a. fer to
⇒ “3.6.41
• Or Oxygen
• Upper limit of Sensor 2
lambda control‐ Before Cat‐
ler output n.a. alytic Con‐
verter
• And GX11 ,
Checking”,
• Evap purge flow page 978 .
at min. value
– Check the
intake sys‐
tem visually
for leaks
(false air).
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0175 Fuel Sys‐ • Lambda • Lambda control • 180.0 s • 2 DCY – Check the
System tem Too controller closed loop Fuel Deliv‐
Too Rich Rich output < • Continu‐ ery Unit -
Bank 2 -37.0 % • Mass air flow > ous GX1- . Re‐
76.0 mg/rev fer to
• Engine speed > ⇒ “3.6.23
544 RPM Fuel Deliv‐
ery Unit
• ECT @ cylinder GX1 ,
block > 70° C Checking”,
page 940 .
• IAT at intake
manifold > -11° – Check the
C pressure in
the fuel sys‐
• AAT > -48° C tem for out
• Ethanol value of spec con‐
n.a. ditions be‐
fore diag‐
• Oil dilution not nosing the
detected pressure
sensor. Re‐
• And fer to Fuel
• Evap purge System Me‐
valve closed chanical
Testing in
• Or ⇒ “3.1 Pre‐
liminary
• Canister load <= Check”,
2.00 [-] page 20 .
• Evap purge flow
at max. value – Check the
Oxygen
• Or Sensor 2
Before Cat‐
• Depending on alytic Con‐
canister purge verter -
min: GX11- . Re‐
fer to
• Lower limit of ⇒ “3.6.41
lambda control‐ Oxygen
ler output n.a. Sensor 2
• Or Before Cat‐
alytic Con‐
• Upper limit of verter
lambda control‐ GX11 ,
ler output n.a. Checking”,
page 978 .
• And
• Evap purge flow – Check the
at min. value intake sys‐
tem visually
for leaks
(false air).
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P017B Engine • Difference • ECT @ cylinder • 10.0 s • 2 DCY – Check the
Cylinder Coolant between head -128 – 40° Engine
Head Tempera‐ modelled C • Once / Coolant
Tempera‐ ture Sen‐ and meas‐ DCY Tempera‐
ture Sen‐ sor @ ured cylin‐ • Time after en‐ ture Sensor
sor Circuit Cylinder der head gine start > 0.0 s - G62- . Re‐
Range/ Head Ra‐ tempera‐ fer to
Perform‐ tionality ture > 0.0 K ⇒ “3.6.17
ance Check Engine
Low Coolant
Tempera‐
ture Sensor
G62 ,
Checking”,
page 928 .
– Check the
Engine
Tempera‐
ture Control
Sensor -
G694- . Re‐
fer to
⇒ “3.6.19
Engine
Tempera‐
ture Control
Sensor
G694 ,
Checking”,
page 932 .
– Check the
Cylinder
Head Cool‐
ant Valve -
N489- . Re‐
fer to
⇒ “3.6.15
Cylinder
Head Cool‐
ant Valve
N489 ,
Checking”,
page 924 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P017C Engine • ECT sensor • 0.5 s • 2 DCY – Check the
Cylinder Coolant voltage @ Engine
Head Tempera‐ cylinder • Continu‐ Coolant
Tempera‐ ture Sen‐ head <= ous Tempera‐
ture Sen‐ sor @ 0.30 V ture Sensor
sor Circuit Cylinder - G62- . Re‐
Low Head fer to
Short To ⇒ “3.6.17
Ground Engine
Coolant
Tempera‐
ture Sensor
G62 ,
Checking”,
page 928 .
– Check the
Engine
Tempera‐
ture Control
Sensor -
G694- . Re‐
fer to
⇒ “3.6.19
Engine
Tempera‐
ture Control
Sensor
G694 ,
Checking”,
page 932 .
– Check the
Cylinder
Head Cool‐
ant Valve -
N489- . Re‐
fer to
⇒ “3.6.15
Cylinder
Head Cool‐
ant Valve
N489 ,
Checking”,
page 924 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P017D Engine • ECT sensor • IAT @ throttle • 0.5 s • 2 DCY – Check the
Cylinder Coolant voltage @ >= -33° C Engine
Head Tempera‐ cylinder • Continu‐ Coolant
Tempera‐ ture Sen‐ head > 4.70 • Time after en‐ ous Tempera‐
ture Sen‐ sor @ V gine start > 60.0 ture Sensor
sor Circuit Cylinder s - G62- . Re‐
High Head fer to
Short To ⇒ “3.6.17
Battery / Engine
Open Cir‐ Coolant
cuit Tempera‐
ture Sensor
G62 ,
Checking”,
page 928 .
– Check the
Engine
Tempera‐
ture Control
Sensor -
G694- . Re‐
fer to
⇒ “3.6.19
Engine
Tempera‐
ture Control
Sensor
G694 ,
Checking”,
page 932 .
– Check the
Cylinder
Head Cool‐
ant Valve -
N489- . Re‐
fer to
⇒ “3.6.15
Cylinder
Head Cool‐
ant Valve
N489 ,
Checking”,
page 924 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0190 Fuel Sys‐ • High fuel • 2.0 s • 2 DCY – Check the
Fuel Pres‐ tem Pres‐ pressure pressure in
sure Reg‐ sure Sen‐ sensor volt‐ • Continu‐ the fuel sys‐
ulator 1 sor, High age > 4.80 ous tem for out
Control Pressure V of spec con‐
Circuit/ Side ditions be‐
Open Short To fore diag‐
Battery / nosing the
Open Cir‐ pressure
cuit sensor. Re‐
fer to Fuel
System Me‐
chanical
Testing in
⇒ “3.1 Pre‐
liminary
Check”,
page 20 .
– Check the
Fuel Pres‐
sure Sensor
- G247- .
Refer to
⇒ “3.6.27
Fuel Pres‐
sure Sensor
G247 ,
Checking”,
page 948 .
P0191 Fuel Rail, • Fuel pres‐ • Engine running • 2.5 s • 2 DCY – Check the
Fuel Rail High sure > pressure in
Pressure Pressure 27,900.09 • Engine speed < • Continu‐ the fuel sys‐
Sensor Side Out kPa 3,264 RPM ous tem for out
Circuit Of Range • Time after en‐ of spec con‐
Range/ High gine start > 10.0 ditions be‐
Perform‐ s fore diag‐
ance Bank nosing the
1 pressure
sensor. Re‐
fer to Fuel
System Me‐
chanical
Testing in
⇒ “3.1 Pre‐
liminary
Check”,
page 20 .
– Check the
Fuel Pres‐
sure Sensor
- G247- .
Refer to
⇒ “3.6.27
Fuel Pres‐
sure Sensor
G247 ,
Checking”,
page 948 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0192 Fuel Sys‐ • High fuel • 2.0 s • 2 DCY – Check the
Fuel Rail tem Pres‐ pressure pressure in
Pressure sure Sen‐ sensor volt‐ • Continu‐ the fuel sys‐
Sensor sor, High age < 0.20 ous tem for out
Circuit Pressure V of spec con‐
Low Bank Side ditions be‐
1 Short To fore diag‐
Ground nosing the
pressure
sensor. Re‐
fer to Fuel
System Me‐
chanical
Testing in
⇒ “3.1 Pre‐
liminary
Check”,
page 20 .
– Check the
Fuel Pres‐
sure Sensor
- G247- .
Refer to
⇒ “3.6.27
Fuel Pres‐
sure Sensor
G247 ,
Checking”,
page 948 .
P0201 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 1 Valves tern for active CRK Cylinder 1
Injector Open Cir‐ open circuit Fuel Injec‐
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ tor - N30- .
stage diag‐ block >= -48° C ous Refer to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via
Error power
stage diag‐
nosis detec‐
ted
• And
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent > 25.0
A
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Injector • ECT @ cylinder
load resist‐ block >= -48° C
ance to
ground and • Engine speed <
battery > 7,000 RPM
20.0 Ω • Injection time >=
• Injector low 0.0 s
side switch
current >
25.0 A
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ω
• Injector
high side
switch cur‐
rent > 25.0
A
P0202 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 2 Valves tern for active CRK Cylinder 2
Injector Open Cir‐ open circuit Fuel Injec‐
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ tor - N31- .
stage diag‐ block >= -48° C ous Refer to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via
Error power
stage diag‐
nosis detec‐
ted
• And
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent > 25.0
A
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Injector • ECT @ cylinder
load resist‐ block >= -48° C
ance to
ground and • Engine speed <
battery > 7,000 RPM
20.0 Ω • Injection time >=
• Injector low 0.0 s
side switch
current >
25.0 A
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ω
• Injector
high side
switch cur‐
rent > 25.0
A
P0203 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 3 Valves tern for active CRK Cylinder 3
Injector Open Cir‐ open circuit Fuel Injec‐
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ tor - N32- .
stage diag‐ block >= -48° C ous Refer to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via
Error power
stage diag‐
nosis detec‐
ted
• And
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent > 25.0
A
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Injector • ECT @ cylinder
load resist‐ block >= -48° C
ance to
ground and • Engine speed <
battery > 7,000 RPM
20.0 Ω • Injection time >=
• Injector low 0.0 s
side switch
current >
25.0 A
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ω
• Injector
high side
switch cur‐
rent > 25.0
A
P0204 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 4 Valves tern for active CRK Cylinder 4
Injector Open Cir‐ open circuit Fuel Injec‐
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ tor - N33- .
stage diag‐ block >= -48° C ous Refer to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via
Error power
stage diag‐
nosis detec‐
ted
• And
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent > 25.0
A
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Injector • ECT @ cylinder
load resist‐ block >= -48° C
ance to
ground and • Engine speed <
battery > 7,000 RPM
20.0 Ω • Injection time >=
• Injector low 0.0 s
side switch
current >
25.0 A
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ω
• Injector
high side
switch cur‐
rent > 25.0
A
P0205 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 5 Valves tern for active CRK Cylinder 5
Injector Open Cir‐ open circuit Fuel Injec‐
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ tor - N83- .
stage diag‐ block >= -48° C ous Refer to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via
Error power
stage diag‐
nosis detec‐
ted
• And
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent > 25.0
A
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Injector • ECT @ cylinder
load resist‐ block >= -48° C
ance to
ground and • Engine speed <
battery > 7,000 RPM
20.0 Ω • Injection time >=
• Injector low 0.0 s
side switch
current >
25.0 A
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ω
• Injector
high side
switch cur‐
rent > 25.0
A
P0206 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 6 Valves tern for active CRK Cylinder 6
Injector Open Cir‐ open circuit Fuel Injec‐
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ tor - N84- .
stage diag‐ block >= -48° C ous Refer to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via
Error power
stage diag‐
nosis detec‐
ted
• And
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent > 25.0
A
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current >
25.0 A
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current
(hardware
values) >
9.0 – 14.0 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Injector • ECT @ cylinder
load resist‐ block >= -48° C
ance to
ground and • Engine speed <
battery > 7,000 RPM
20.0 Ω • Injection time >=
• Injector low 0.0 s
side switch
current >
25.0 A
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ω
• Injector
high side
switch cur‐
rent > 25.0
A
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0223 Throttle • Throttle po‐ • 0.2 s • 2 DCY – Check the
Throttle/ Position sition sen‐ Throttle
Pedal Po‐ Sensor 2 sor 2 volt‐ • Continu‐ Valve Con‐
sition Sen‐ Short To age > 4.85 ous trol Module
sor/Switch Battery V - GX3- . Re‐
"B" Circuit Plus fer to
High ⇒ “3.6.45
Throttle
Valve Con‐
trol Module
GX3 ,
Checking”,
page 987 .
P0230 CAN: • Fuel pump • Engine on • 2.0 s • 2 DCY – Check the
Fuel Pump Fuel sensor: Fuel Deliv‐
Primary Pump short to • Continu‐ ery Unit -
Circuit CAN ground fail‐ ous GX1- . Re‐
Malfunc‐ Commu‐ ure feed‐ fer to
tion nication back >= 2.0 ⇒ “3.6.23
With Fuel [-] Fuel Deliv‐
Pump ery Unit
• Fuel pump • 2.2 s GX1 ,
sensor: Checking”,
open circuit • Continu‐ page 940 .
failure feed‐ ous
back >= 2.0
[-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0235 Super‐ • Diff. set • Engine running • 1.0 s • 2 DCY – Check the
Turbo‐ charger point ratio of Charge Air
charger/ (SC) supercharg‐ • Time after en‐ • Continu‐ Pressure
Super‐ Boost er boost gine start > 10.0 ous Sensor -
charger Pressure pressure s G31- / In‐
Boost Control and MAP • Barometric take Mani‐
Sensor "A" Rationali‐ upstream pressure 63.0 – fold Tem‐
Circuit ty Check supercharg‐ 105.0 kPa perature
High er vs. meas‐ Sensor -
ured ratio of • Engine speed 0 G72- . Refer
supercharg‐ – 8,160 RPM to
er boost ⇒ “3.6.10
pressure • IAT @ manifold Charge Air
and MAP > 5° C Pressure
upstream Sensor
• ECT @ cylinder
supercharg‐ G31 / Intake
block > -48° C
er > 0.25 – Manifold
0.35 [-] • Diff. engine Tempera‐
speed vs. fil‐ ture Sensor
• For time >= G72 ,
tered engine
1.5 s Checking”,
speed for engine
speed dynamic page 914 .
detection < 96
RPM – Check the
charge air
• Diff. air mass set system for
point vs. filtered proper seal.
air mass set Refer to En‐
point for load dy‐ gine Me‐
namic detection chanical,
< 15.01 mg/rev Fuel Injec‐
tion and Ig‐
• Fuel cut off not nition,
active Charge Air
• Pressure gradi‐ System.
ent @ pressure
sensor up‐
stream super‐
charger
-8,291.80 –
8,291.50 kPa/s
• Gradient super‐
charger boost
pressure
-1,500.0 –
1,500.0 kPa/s
• Engine speed
limitation not ac‐
tive
• Fast throttle
adaptation fin‐
ished
• Engine speed >
1,504 RPM
• SCB power
stage enabled
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Set point ratio of
supercharger
boost pressure
and MAP up‐
stream super‐
charger >= 1.25;
< 2.50 [-]
• Measured IAT
@ manifold <=
75° C
• Measured IAT
@ manifold 2 <=
75° C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0236 Manifold • Diff. pres‐ • Engine @ driv‐ • 3.0 s • 2 DCY – Check the
Turbo‐ Pressure sure down‐ ing cycle not Charge Air
charger/ Sensor stream started the first • Continu‐ Pressure
Super‐ Engine throttle vs. time ous Sensor -
charger Off: manifold G31- / In‐
Boost Cross pressure >= • Vehicle speed < take Mani‐
Sensor "A" Check 7.0 kPa 1 mph fold Tem‐
Circuit perature
Range/ • Diff. mani‐ Sensor -
Perform‐ fold pres‐ G72- . Refer
ance sure vs. to
manifold ⇒ “3.6.10
pressure 2 Charge Air
>= 7.0 kPa Pressure
• Or Sensor
G31 / Intake
• Diff. pres‐ Manifold
sure down‐ Tempera‐
stream ture Sensor
throttle vs. G72 ,
manifold Checking”,
pressure >= page 914 .
7.0 kPa
– Check the
• Diff. baro‐ charge air
metric pres‐ system for
sure vs. proper seal.
manifold Refer to En‐
pressure >= gine Me‐
7.0 kPa chanical,
Fuel Injec‐
• Or tion and Ig‐
• Diff. baro‐ nition,
metric pres‐ Charge Air
sure vs. System.
manifold
pressure >=
7.0 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion pres‐
sure MAP to
mean value
(MAP 2 and
BARO) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(MAP2 and
BARO) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.0 kPa
• Diff. devia‐
tion pres‐
sure MAP to
mean value
(MAP 2 and
pressure
down‐
stream
throttle) vs.
deviation
BARO to
mean value
(MAP2 and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion pres‐
sure MAP to
mean value
(BARO and
pressure
down‐
stream
throttle) vs.
deviation
MAP 2 to
mean value
(BARO and
pressure
down‐
stream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Manifold • Case 1: • Modeled pres‐
Pressure sure quotient
Sensor • Diff. mani‐ (downstream /
Idle fold pres‐ upstream throt‐
Speed: sure vs.
Cross manifold
Check pressure 2
>= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
< 8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐ tle) 0.30 – 0.45
tion pres‐ [-]
sure MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion pres‐
sure MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Manifold • Diff. pres‐ • Engine stopped
Pressure sure down‐
Sensor stream
ECM throttle vs.
Keep manifold
Alive pressure >=
Time: 7.0 kPa
Cross
Check • Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.0 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.0 kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.0 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐ • Vehicle speed <
tion MAP to 1 mph
mean value
(MAP 2 and • ECM keep alive
BARO) vs. time > 10.0 s
deviation • Time after en‐
pressure gine stop >= 4.0
down‐ s
stream
throttle to • Barometric
mean value pressure 55.0 –
(MAP2 and 110.0 kPa
BARO) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.0 kPa
• Diff. devia‐
tion MAP to
mean value
(MAP 2 and
pressure
down‐
stream
throttle) vs.
deviation
BARO to
mean value
(MAP 2 and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion MAP to
mean value
(BARO and
pressure
down‐
stream
throttle) vs.
deviation
MAP 2 to
mean value
(BARO and
pressure
down‐
stream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Manifold • Case 1: • Engine running
Pressure
Sensor • Diff. pres‐
Engine sure down‐
Running stream
Non throttle vs.
Charged manifold
Engine: pressure >=
Cross 12.0 – 27.0
Check kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
< 12.0 –
27.0 kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
12.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐ • Modeled pres‐
tion MAP to sure quotient
mean value (downstream /
(pressure upstream throt‐
down‐ tle) > 0.45; <=
stream 0.80 [-]
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Manifold • Case 1: • Fuel cut off ac‐
Pressure tive
Sensor • Diff. mani‐
Fuel Cut fold pres‐ • Modeled pres‐
Off: sure vs. sure quotient
Cross manifold (downstream /
Check pressure 2 upstream throt‐
>= 8.0 – tle) 0.25 – 0.30
27.0 kPa [-]
• Diff. pres‐ • For time >= 5.0 s
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
< 8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0237 Manifold • Manifold • 0.5 s • 2 DCY – Check the
Turbo‐ Pressure pressure Charge Air
charger/ Sensor signal fail‐ • Continu‐ Pressure
Super‐ Internal ure ous Sensor -
charger Fault G31- / In‐
Boost take Mani‐
Sensor "A" fold Tem‐
Circuit perature
Low Sensor -
G72- . Refer
to
⇒ “3.6.10
Charge Air
Pressure
Sensor
G31 / Intake
Manifold
Tempera‐
ture Sensor
G72 ,
Checking”,
page 914 .
– Check the
charge air
system for
proper seal.
Refer to En‐
gine Me‐
chanical,
Fuel Injec‐
tion and Ig‐
nition,
Charge Air
System.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0238 Manifold • Manifold • 0.5 s • 2 DCY – Check the
Turbo‐ Pressure pressure Charge Air
charger/ Sensor signal fail‐ • Continu‐ Pressure
Super‐ Internal ure ous Sensor -
charger Fault G31- / In‐
Boost • Or take Mani‐
Sensor "A" • Checksum fold Tem‐
Circuit signal fail‐ perature
High ure Sensor -
G72- . Refer
• Or to
⇒ “3.6.10
• Communi‐ Charge Air
cation sig‐ Pressure
nal failed Sensor
G31 / Intake
Manifold
Tempera‐
ture Sensor
G72 ,
Checking”,
page 914 .
– Check the
charge air
system for
proper seal.
Refer to En‐
gine Me‐
chanical,
Fuel Injec‐
tion and Ig‐
nition,
Charge Air
System.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0240 Manifold • Diff. pres‐ • Engine @ driv‐ • 3.0 s • 2 DCY – Check the
Turbo‐ Pressure sure down‐ ing cycle not Charge Air
charger/ Sensor 2 stream started the first • Continu‐ Pressure
Super‐ Engine throttle vs. time ous Sensor 2 -
charger Off: manifold G447- / In‐
Boost Cross pressure 2 • Vehicle speed < take Mani‐
Sensor "B" Check >= 7.0 kPa 1 mph fold Tem‐
Circuit perature
Range/ • Diff. mani‐ Sensor 2 -
Perform‐ fold pres‐ G430- . Re‐
ance sure vs. fer to
manifold ⇒ “3.6.11
pressure 2 Intake
>= 7.0 kPa Manifold
• Or Tempera‐
ture Sensor
• Diff. pres‐ 2 G430 /
sure down‐ Charge Air
stream Pressure
throttle vs. Sensor 2
manifold G447 ,
pressure 2 Checking”,
>= 7.0 kPa page 916 .
• Diff. baro‐ – Check the
metric pres‐ charge air
sure vs. system for
manifold proper seal.
pressure 2 Refer to En‐
>= 7.0 kPa gine Me‐
chanical,
• Or Fuel Injec‐
• Diff. baro‐ tion and Ig‐
metric pres‐ nition,
sure vs. Charge Air
manifold System.
pressure 2
>= 7.0 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion MAP 2
to mean val‐
ue (MAP
and BARO)
vs. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(MAP and
BARO) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Diff. devia‐
tion MAP 2
to mean val‐
ue (MAP
and pres‐
sure down‐
stream
throttle) vs.
deviation
BARO to
mean value
(MAP and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion MAP 2
to mean val‐
ue (BARO
and pres‐
sure down‐
stream
throttle) vs.
deviation
MAP to
mean value
(BARO and
pressure
down‐
stream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Manifold • Case 1: • Modeled pres‐
Pressure sure quotient
Sensor 2 • Diff. mani‐ (downstream /
Idle fold pres‐ upstream throt‐
Speed: sure vs.
Cross manifold
Check pressure 2
>= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure <
8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐ tle) 0.30 – 0.45
tion MAP 2 [-]
to mean val‐
ue (pres‐
sure down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP 2
to mean val‐
ue (pres‐
sure down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Manifold • Diff. pres‐ • Engine stopped
Pressure sure down‐
Sensor 2 stream
ECM throttle vs.
Keep manifold
Alive pressure 2
Time: >= 7.0 kPa
Cross
Check • Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.0 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐ • Vehicle speed <
tion MAP 2 1 mph
to mean val‐
ue (MAP • ECM keep alive
and BARO) time > 10.0 s
vs. devia‐ • Time after en‐
tion pres‐ gine stop >= 4.0
sure down‐ s
stream
throttle to • Barometric
mean value pressure 55.0 –
(MAP and 110.0 kPa
BARO) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Diff. devia‐
tion MAP 2
to mean val‐
ue (MAP
and pres‐
sure down‐
stream
throttle) vs.
deviation
BARO to
mean value
(MAP and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion MAP 2
to mean val‐
ue (BARO
and pres‐
sure down‐
stream
throttle) vs.
deviation
MAP to
mean value
(BARO and
pressure
down‐
stream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Manifold • Case 1: • Engine running
Pressure
Sensor 2 • Diff. pres‐
Engine sure down‐
Running stream
Non throttle vs.
Charged manifold
Engine: pressure 2
Cross >= 12.0 –
Check 27.0 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure <
12.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
12.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐ • Modeled pres‐
tion MAP 2 sure quotient
to mean val‐ (downstream /
ue (pres‐ upstream throt‐
sure down‐ tle) > 0.45; <=
stream 0.80 [-]
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Manifold • Case 1: • Fuel cut off ac‐
Pressure tive
Sensor 2 • Diff. mani‐
Fuel Cut fold pres‐ • Modeled pres‐
Off: sure vs. sure quotient
Cross manifold (downstream /
Check pressure 2 upstream throt‐
>= 8.0 – tle) 0.25 – 0.30
27.0 kPa [-]
• Diff. pres‐ • For time >= 5.0 s
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure <
8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion MAP 2
to mean val‐
ue (pres‐
sure down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0241 Manifold • Manifold • 0.5 s • 2 DCY – Check the
Turbo‐ Pressure pressure Charge Air
charger/ Sensor 2 signal fail‐ • Continu‐ Pressure
Super‐ Internal ure ous Sensor 2 -
charger Fault G447- / In‐
Boost take Mani‐
Sensor "B" fold Tem‐
Circuit perature
Low Sensor 2 -
G430- . Re‐
fer to
⇒ “3.6.11
Intake
Manifold
Tempera‐
ture Sensor
2 G430 /
Charge Air
Pressure
Sensor 2
G447 ,
Checking”,
page 916 .
– Check the
charge air
system for
proper seal.
Refer to En‐
gine Me‐
chanical,
Fuel Injec‐
tion and Ig‐
nition,
Charge Air
System.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0242 Manifold • Manifold • 0.5 s • 2 DCY – Check the
Turbo‐ Pressure pressure Charge Air
charger/ Sensor 2 signal fail‐ • Continu‐ Pressure
Super‐ Internal ure ous Sensor 2 -
charger Fault G447- / In‐
Boost • Or take Mani‐
Sensor "B" • Checksum fold Tem‐
Circuit signal fail‐ perature
High ure Sensor 2 -
G430- . Re‐
• Or fer to
⇒ “3.6.11
• Communi‐ Intake
cation sig‐ Manifold
nal failed Tempera‐
ture Sensor
2 G430 /
Charge Air
Pressure
Sensor 2
G447 ,
Checking”,
page 916 .
– Check the
charge air
system for
proper seal.
Refer to En‐
gine Me‐
chanical,
Fuel Injec‐
tion and Ig‐
nition,
Charge Air
System.
P025A Fuel • Signal volt‐ • Commanded • 0.5 s • 2 DCY – Check the
Fuel Pump Pump age, lower PWM 9.80 – Fuel Deliv‐
Module Open Cir‐ range > 90.20 % • Continu‐ ery Unit -
"A" Control cuit 1.92 – 2.21 ous GX1- . Re‐
Circuit/ V • Fuel pump com‐ fer to
Open manded off ⇒ “3.6.23
• And Fuel Deliv‐
• Signal volt‐ ery Unit
age, upper GX1 ,
range Checking”,
(hardware page 940 .
values) <
2.84 – 3.25
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P025B Fuel Sys‐ • Case 1: • Engine speed > • 5.0 s • 2 DCY – Check the
Fuel Pump tem Con‐ 512; <= 4,512 Fuel Deliv‐
Module trol, Low • Actual and RPM • Continu‐ ery Unit -
Control Pressure adapted I- ous GX1- . Re‐
Circuit Side Ra‐ part of elec‐ • Electric fuel fer to
Range/ tionality tric fuel pump active ⇒ “3.6.23
Perform‐ Check pump con‐ Fuel Deliv‐
troller • Time after en‐
ance gine start > 12.0 ery Unit
(PWM sig‐ GX1 ,
nal) > 28.0 s
Checking”,
% • ECT @ cylinder page 940 .
• Or block 70 – 106°
C
• Actual and
adapted I- • Fuel mass set
part of elec‐ point for low
tric fuel pressure-part
pump con‐ 6.0 – 65.0 mg/
troller rev
(PWM sig‐ • Fuel pressure
nal) < -23.0 pump not at
% max. limit
• Case 2:
• Adapted I-
part of elec‐
tric fuel
pump con‐
troller
(PWM sig‐
nal) > n.a.
%
• Or
• Adapted I-
part of elec‐
tric fuel
pump con‐
troller
(PWM sig‐
nal) < n.a.
%
• Adapted I-
part of elec‐
tric fuel
pump con‐
troller
(PWM sig‐
nal) > 50.0
%
• Or
• Adapted I-
part of elec‐
tric fuel
pump con‐
troller
(PWM sig‐
nal) < -50.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Diff. fuel • Engine speed >
tem Con‐ pressure 512; <= 4,512
trol, Low set point vs. RPM
Pressure actual fuel
Side pressure > • Electric fuel
Function‐ 170.08 kPa pump active
al Check
• Electric fuel • Time after en‐
pump gine start > 12.0
(PWM sig‐ s
nal) > 0.0 % • ECT @ cylinder
• For time >= block 70 – 106°
12.0 s C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0261 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 1 Valves tern for active CRK Cylinder 1
Injector Short To short to Fuel Injec‐
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ tor - N30- .
Low power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • Injector
driver high
side switch
current <
25.0 A
• And
• injector
driver low
side switch
current
(hardware
values) <
25.0 A
P0262 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 1 Valves tern for active CRK Cylinder 1
Injector Short To short to bat‐ Fuel Injec‐
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ tor - N30- .
High Plus power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Injector • Engine running • 720°
Valves driver volt‐ CRK
Short To age > 2.0 V • ECT @ cylinder
Battery block >= -48° C • Continu‐
Plus • And ous
• Engine speed <
(High • Injector 7,000 RPM
Side) driver high
side switch • Injection time >=
current 0 ms
(hardware
values) >
25.0 A
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values) >
25.0 A
P0264 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 2 Valves tern for active CRK Cylinder 2
Injector Short To short to Fuel Injec‐
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ tor - N31- .
Low power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • injector
driver high
side switch
current <
25.0 A
• And
• injector
driver low
side switch
current
(hardware
values) <
25.0 A
P0265 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 2 Valves tern for active CRK Cylinder 2
Injector Short To short to bat‐ Fuel Injec‐
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ tor - N31- .
High Plus power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values) >
25.0 A
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0267 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 3 Valves tern for active CRK Cylinder 3
Injector Short To short to Fuel Injec‐
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ tor - N32- .
Low power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • injector
driver high
side switch
current <
25.0 A
• And
• injector
driver low
side switch
current
(hardware
values) <
25.0 A
P0268 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 3 Valves tern for active CRK Cylinder 3
Injector Short To short to bat‐ Fuel Injec‐
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ tor - N32- .
High Plus power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Injector • Engine running • 720°
Valves driver volt‐ CRK
Short To age > 2.0 V • ECT @ cylinder
Battery block >= -48° C • Continu‐
Plus • And ous
• Engine speed <
(High • Injector 7,000 RPM
Side) driver high
side switch • Injection time >=
current 0.0 ms
(hardware
values) >
25.0 A
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values) >
25.0 A
P0270 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 4 Valves tern for active CRK Cylinder 4
Injector Short To short to Fuel Injec‐
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ tor - N33- .
Low power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • injector
driver high
side switch
current <
25.0 A
• And
• injector
driver low
side switch
current
(hardware
values) <
25.0 A
P0271 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 4 Valves tern for active CRK Cylinder 4
Injector Short To short to bat‐ Fuel Injec‐
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ tor - N33- .
High Plus power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values) >
25.0 A
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0273 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 5 Valves tern for active CRK Cylinder 5
Injector Short To short to Fuel Injec‐
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ tor - N83- .
Low power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • injector
driver high
side switch
current <
25.0 A
• And
• injector
driver low
side switch
current
(hardware
values) <
25.0 A
P0274 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 5 Valves tern for active CRK Cylinder 5
Injector Short To short to bat‐ Fuel Injec‐
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ tor - N83- .
High Plus power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Injector • Engine running • 720°
Valves driver volt‐ CRK
Short To age > 2.0 V • ECT @ cylinder
Battery block >= -48° C • Continu‐
Plus • And ous
• Engine speed <
(High • Injector 7,000 RPM
Side) driver high
side switch • Injection time >=
current 0.0 ms
(hardware
values) >
25.0 A
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values) >
25.0 A
P0276 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 6 Valves tern for active CRK Cylinder 6
Injector Short To short to Fuel Injec‐
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ tor - N84- .
Low power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • injector
driver high
side switch
current <
25.0 A
• And
• injector
driver low
side switch
current
(hardware
values) <
25.0 A
P0277 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 6 Valves tern for active CRK Cylinder 6
Injector Short To short to bat‐ Fuel Injec‐
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ tor - N84- .
High Plus power block >= -48° C ous Refer to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values) >
25.0 A
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0300 Misfire • Number of • Emission • 1,000 • 2 DCY – Check the
Random/ Crank‐ cylinders threshold misfire revolu‐ Cylinder 1
Multiple shaft with emis‐ detected tions Fuel Injec‐
Cylinder Speed sion thresh‐ tor - N30- .
Misfire De‐ Fluctua‐ old misfire • Continu‐ Refer to
tected tion (Mul‐ within 4,000 ous ⇒ “3.6.24
tiple) revolutions Fuel Injec‐
>= 2.00 [-] tors, Check‐
ing”,
• Or page 942 .
• Number of
cylinders – Check the
with emis‐ Ignition Coil
sion thresh‐ with Power
old misfire Output
within 1,000 Stage -
revolutions N70- . Refer
>= 2.00 [-] to
⇒ “3.6.29
Ignition
• Number of • Catalyst damag‐ • 200 rev‐ • Immedi‐ Coils With
cylinders ing misfire de‐ olutions ately Power Out‐
with cata‐ tected put Stage ,
lyst damag‐ • Continu‐
ous Checking”,
ing misfire page 952 .
>= 2.0 [-]
– Check the
Engine
Component
Power Sup‐
ply Relay -
J757- . Re‐
fer to
⇒ “3.6.16
Engine
Component
Power Sup‐
ply Relay
J757 ,
Checking”,
page 926 .
– Check the
spark plugs
visually.
– Check the
pressure in
the fuel sys‐
tem for out
of spec con‐
ditions be‐
fore diag‐
nosing the
pressure
sensor. Re‐
fer to Fuel
System Me‐
chanical
Testing in
⇒ “3.1 Pre‐
liminary
Check”,
page 20 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0301 Misfire • Catalyst • Initial engine • 200 rev‐ • Immedi‐ – Check the
Cylinder 1 Crank‐ damage speed > 550 olutions ately Cylinder 1
Misfire De‐ shaft misfire for RPM Fuel Injec‐
tected Speed A/T: • Continu‐ tor - N30- .
Fluctua‐ • Engine speed > ous Refer to
tion (Sin‐ • Catalyst 500 RPM ⇒ “3.6.24
gle Or damaging Fuel Injec‐
Multiple) misfire rate • Engine speed <
tors, Check‐
> 0.83 – 6,820 RPM
ing”,
13.89 % • Time after en‐ page 942 .
• For DC/T: gine start > n.a.
s – Check the
• Catalyst Ignition Coil
damaging • And with Power
misfire rate • Output
Depending on
> 0.83 – Stage -
transmission
13.89 % N70- . Refer
mode for M/T: to
• For CV/T: • Engine load > ⇒ “3.6.29
100.0 % Ignition
• Catalyst Coils With
damaging • For A/T: Power Out‐
misfire rate put Stage ,
> 109.23 – • Engine load > Checking”,
1,820.42 % 4.50 – 41.20 % page 952 .
• For M/T: • For CV/T:
– Check the
• Catalyst • Engine load > spark plugs
damaging 97.50 – 103.0 % visually.
misfire rate
> 109.23 – • For DC/T: – Check the
1,820.42 % • pressure in
Engine load >
97.50 – 103.0 % the fuel sys‐
tem for out
• For M/T 4WD: of spec con‐
ditions be‐
• Engine load > fore diag‐
100.0 % nosing the
pressure
• For DC/T 4WD: sensor. Re‐
• Engine load > fer to Fuel
97.50 – 103.0 % System Me‐
chanical
• And Testing in
⇒ “3.1 Pre‐
• Depending on liminary
ECT @ cylinder Check”,
block @ start page 20 .
• ECT @ cylinder
block @ engine
start <= -8° C
• Then activation
if
• ECT @ cylinder
block >= 20° C
• Or
• ECT @ cylinder
block @ engine
start > -8° C
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • Fuel cut off not • 1,000 • 2 DCY
threshold active revolu‐
misfire with‐ • Or tions
in 1,000 rev
• Single fuel cut • Continu‐
• For A/T: ous
off not active
• emission • Or
threshold
misfire rate • Number of fade
(MR) > 1.10 out cylinders <
[%] 3.00 [-]
• For DT/C: • And
• emission • Dynamic mani‐
threshold fold air pressure
misfire rate <= n.a. kPa
(MR) > 1.10
[%] • Dynamic throttle
position <= n.a.°
• For CV/T: TPS/s
• emission • And
threshold
misfire rate • Engine n.a.
(MR) >
2184.50 [%] • Engine speed <
n.a. RPM
• For M/T:
• Dynamic of igni‐
• emission tion angle <=
threshold n.a.° CRK
misfire rate
(MR) > • Or
2184.50 [%] • Dynamic of igni‐
tion angle <=
n.a.° CRK
• And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • 4x • 2 DCY
threshold 1,000
misfire with‐ revolu‐
in 4,000 rev tions
• For A/T: • Continu‐
ous
• emission
threshold
misfire rate
(MR) > 1.10
%
• For DC/T:
• emission
threshold
misfire rate
(MR) > 1.10
%
• For CV/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
• For M/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0302 Misfire • Catalyst • Initial engine • 200 rev‐ • Immedi‐ – Check the
Cylinder 2 Crank‐ damage speed > 550 olutions ately Cylinder 2
Misfire De‐ shaft misfire for RPM Fuel Injec‐
tected Speed A/T: • Continu‐ tor - N31- .
Fluctua‐ • Engine speed > ous Refer to
tion (Sin‐ • Catalyst 500 RPM ⇒ “3.6.24
gle Or damaging Fuel Injec‐
Multiple) misfire rate • Engine speed <
tors, Check‐
> 0.83 – 6,820 RPM
ing”,
13.89 % • Time after en‐ page 942 .
• For DC/T: gine start > n.a.
s – Check the
• Catalyst Ignition Coil
damaging • And 2 With Pow‐
misfire rate • er Output
Depending on
> 0.83 – Stage -
transmission
13.89 % N127- . Re‐
mode for M/T: fer to
• For CV/T: • Engine load > ⇒ “3.6.29
100.0 % Ignition
• Catalyst Coils With
damaging • For A/T: Power Out‐
misfire rate put Stage ,
> 109.23 – • Engine load > Checking”,
1,820.42 % 4.50 – 41.20 % page 952 .
• For M/T: • For CV/T:
– Check the
• Catalyst • Engine load > spark plugs
damaging 97.50 – 103.0 % visually.
misfire rate
> 109.23 – • For DC/T: – Check the
1,820.42 % • pressure in
Engine load >
97.50 – 103.0 % the fuel sys‐
tem for out
• For M/T 4WD: of spec con‐
ditions be‐
• Engine load > fore diag‐
100.0 % nosing the
pressure
• For DC/T 4WD: sensor. Re‐
• Engine load > fer to Fuel
97.50 – 103.0 % System Me‐
chanical
• And Testing in
⇒ “3.1 Pre‐
• Depending on liminary
ECT @ cylinder Check”,
block @ start page 20 .
• ECT @ cylinder
block @ engine
start <= -8° C
• Then activation
if
• ECT @ cylinder
block >= 20° C
• Or
• ECT @ cylinder
block @ engine
start > -8° C
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • Fuel cut off not • 1,000 • 2 DCY
threshold active revolu‐
misfire with‐ • Or tions
in 1,000 rev
• Single fuel cut • Continu‐
• For A/T: ous
off not active
• emission • Or
threshold
misfire rate • Number of fade
(MR) > 1.10 out cylinders <
% 3.00 [-]
• For DT/C: • And
• emission • Dynamic mani‐
threshold fold air pressure
misfire rate <= n.a. kPa
(MR) > 1.10
% • Dynamic throttle
position <= n.a.°
• For CV/T: TPS/s
• emission • And
threshold
misfire rate • Engine n.a.
(MR) >
2,184.50 % • Engine speed <
n.a. RPM
• For M/T:
• Dynamic of igni‐
• emission tion angle <=
threshold n.a.° CRK
misfire rate
(MR) > • Or
2,184.50 % • Dynamic of igni‐
tion angle <=
n.a.° CRK
• And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • 4x • 2 DCY
threshold 1,000
misfire with‐ revolu‐
in 4,000 rev tions
• For A/T: • Continu‐
ous
• emission
threshold
misfire rate
(MR) > 1.10
%
• For DC/T:
• emission
threshold
misfire rate
(MR) > 1.10
%
• For CV/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
• For M/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0303 Misfire • Catalyst • Initial engine • 200 rev‐ • Immedi‐ – Check the
Cylinder 3 Crank‐ damage speed > 550 olutions ately Cylinder 3
Misfire De‐ shaft misfire for RPM Fuel Injec‐
tected Speed A/T: • Continu‐ tor - N32- .
Fluctua‐ • Engine speed > ous Refer to
tion (Sin‐ • Catalyst 500 RPM ⇒ “3.6.24
gle Or damaging Fuel Injec‐
Multiple) misfire rate • Engine speed <
tors, Check‐
> 0.83 – 6,820 RPM
ing”,
13.89 % • Time after en‐ page 942 .
• For DC/T: gine start > n.a.
s – Check the
• Catalyst Ignition Coil
damaging • And with Power
misfire rate • Output
Depending on
> 0.83 – Stage -
transmission
13.89 % N291- . Re‐
mode for M/T: fer to
• For CV/T: • Engine load > ⇒ “3.6.29
100.0 % Ignition
• Catalyst Coils With
damaging • For A/T: Power Out‐
misfire rate put Stage ,
> 109.23 – • Engine load > Checking”,
1,820.42 % 4.50 – 41.20 % page 952 .
• For M/T: • For CV/T:
– Check the
• Catalyst • Engine load > spark plugs
damaging 97.50 – 103.0 % visually.
misfire rate
> 109.23 – • For DC/T: – Check the
1,820.42 % • pressure in
Engine load >
97.50 – 103.0 % the fuel sys‐
tem for out
• For M/T 4WD: of spec con‐
ditions be‐
• Engine load > fore diag‐
100.0 % nosing the
pressure
• For DC/T 4WD: sensor. Re‐
• Engine load > fer to Fuel
97.50 – 103.0 % System Me‐
chanical
• And Testing in
⇒ “3.1 Pre‐
• Depending on liminary
ECT @ cylinder Check”,
block @ start page 20 .
• ECT @ cylinder
block @ engine
start <= -8° C
• Then activation
if
• ECT @ cylinder
block >= 20° C
• Or
• ECT @ cylinder
block @ engine
start > -8° C
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • Fuel cut off not • 1,000 • 2 DCY
threshold active revolu‐
misfire with‐ • Or tions
in 1,000 rev
• Single fuel cut • Continu‐
• For A/T: ous
off not active
• emission • Or
threshold
misfire rate • Number of fade
(MR) > 1.10 out cylinders <
% 3.00 [-]
• For DT/C: • And
• emission • Dynamic mani‐
threshold fold air pressure
misfire rate <= n.a. kPa
(MR) > 1.10
% • Dynamic throttle
position <= n.a.°
• For CV/T: TPS/s
• emission • And
threshold
misfire rate • Engine n.a.
(MR) >
2,184.50 % • Engine speed <
n.a. RPM
• For M/T:
• Dynamic of igni‐
• emission tion angle <=
threshold n.a.° CRK
misfire rate
(MR) > • Or
2,184.50 % • Dynamic of igni‐
tion angle <=
n.a.° CRK
• And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • 4x • 2 DCY
threshold 1,000
misfire with‐ revolu‐
in 4,000 rev tions
• For A/T: • Continu‐
ous
• emission
threshold
misfire rate
(MR) > 1.10
%
• For DC/T:
• emission
threshold
misfire rate
(MR) > 1.10
%
• For CV/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
• For M/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0304 Misfire • Catalyst • Initial engine • 200 rev‐ • Immedi‐ – Check the
Cylinder 4 Crank‐ damage speed > 550 olutions ately Cylinder 4
Misfire De‐ shaft misfire for RPM Fuel Injec‐
tected Speed A/T: • Continu‐ tor - N33- .
Fluctua‐ • Engine speed > ous Refer to
tion (Sin‐ • Catalyst 500 RPM ⇒ “3.6.24
gle Or damaging Fuel Injec‐
Multiple) misfire rate • Engine speed <
tors, Check‐
> 0.83 – 6,820 RPM
ing”,
13.89 % • Time after en‐ page 942 .
• For DC/T: gine start > n.a.
s – Check the
• Catalyst Ignition Coil
damaging • And with Power
misfire rate • Output
Depending on
> 0.83 – Stage -
transmission
13.89 % N292- . Re‐
mode for M/T: fer to
• For CV/T: • Engine load > ⇒ “3.6.29
100.0 % Ignition
• Catalyst Coils With
damaging • For A/T: Power Out‐
misfire rate put Stage ,
> 109.23 – • Engine load > Checking”,
1,820.42 % 4.50 – 41.20 % page 952 .
• For M/T: • For CV/T:
– Check the
• Catalyst • Engine load > spark plugs
damaging 97.50 – 103.0 % visually.
misfire rate
> 109.23 – • For DC/T: – Check the
1,820.42 % • pressure in
Engine load >
97.50 – 103.0 % the fuel sys‐
tem for out
• For M/T 4WD: of spec con‐
ditions be‐
• Engine load > fore diag‐
100.0 % nosing the
pressure
• For DC/T 4WD: sensor. Re‐
• Engine load > fer to Fuel
97.50 – 103.0 % System Me‐
chanical
• And Testing in
⇒ “3.1 Pre‐
• Depending on liminary
ECT @ cylinder Check”,
block @ start page 20 .
• ECT @ cylinder
block @ engine
start <= -8° C
• Then activation
if
• ECT @ cylinder
block >= 20° C
• Or
• ECT @ cylinder
block @ engine
start > -8° C
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • Fuel cut off not • 1,000 • 2 DCY
threshold active revolu‐
misfire with‐ • Or tions
in 1,000 rev
• Single fuel cut • Continu‐
• For A/T: ous
off not active
• emission • Or
threshold
misfire rate • Number of fade
(MR) > 1.10 out cylinders <
% 3.00 [-]
• For DT/C: • And
• emission • Dynamic mani‐
threshold fold air pressure
misfire rate <= n.a. kPa
(MR) > 1.10
% • Dynamic throttle
position <= n.a.°
• For CV/T: TPS/s
• emission • And
threshold
misfire rate • Engine n.a.
(MR) >
2,184.50 % • Engine speed <
n.a. RPM
• For M/T:
• Dynamic of igni‐
• emission tion angle <=
threshold n.a.° CRK
misfire rate
(MR) > • Or
2,184.50 % • Dynamic of igni‐
tion angle <=
n.a.° CRK
• And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • 4x • 2 DCY
threshold 1,000
misfire with‐ revolu‐
in 4,000 rev tions
• For A/T: • Continu‐
ous
• emission
threshold
misfire rate
(MR) > 1.10
%
• For DC/T:
• emission
threshold
misfire rate
(MR) > 1.10
%
• For CV/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
• For M/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0305 Misfire • Catalyst • Initial engine • 200 rev‐ • Immedi‐ – Check the
Cylinder 5 Crank‐ damage speed > 550 olutions ately Cylinder 5
Misfire De‐ shaft misfire for RPM Fuel Injec‐
tected Speed A/T: • Continu‐ tor - N83- .
Fluctua‐ • Engine speed > ous Refer to
tion (Sin‐ • Catalyst 500 RPM ⇒ “3.6.24
gle Or damaging Fuel Injec‐
Multiple) misfire rate • Engine speed <
tors, Check‐
> 0.83 – 6,820 RPM
ing”,
13.89 % • Time after en‐ page 942 .
• For DC/T: gine start > n.a.
s – Check the
• Catalyst Ignition Coil
damaging • And with Power
misfire rate • Output
Depending on
> 0.83 – Stage -
transmission
13.89 % N323- . Re‐
mode for M/T: fer to
• For CV/T: • Engine load > ⇒ “3.6.29
100.0 % Ignition
• Catalyst Coils With
damaging • For A/T: Power Out‐
misfire rate put Stage ,
> 109.23 – • Engine load > Checking”,
1,820.42 % 4.50 – 41.20 % page 952 .
• For M/T: • For CV/T:
– Check the
• Catalyst • Engine load > spark plugs
damaging 97.50 – 103.0 % visually.
misfire rate
> 109.23 – • For DC/T: – Check the
1,820.42 % • pressure in
Engine load >
97.50 – 103.0 % the fuel sys‐
tem for out
• For M/T 4WD: of spec con‐
ditions be‐
• Engine load > fore diag‐
100.0 % nosing the
pressure
• For DC/T 4WD: sensor. Re‐
• Engine load > fer to Fuel
97.50 – 103.0 % System Me‐
chanical
• And Testing in
⇒ “3.1 Pre‐
• Depending on liminary
ECT @ cylinder Check”,
block @ start page 20 .
• ECT @ cylinder
block @ engine
start <= -8° C
• Then activation
if
• ECT @ cylinder
block >= 20° C
• Or
• ECT @ cylinder
block @ engine
start > -8° C
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • Fuel cut off not • 1,000 • 2 DCY
threshold active revolu‐
misfire with‐ • Or tions
in 1,000 rev
• Single fuel cut • Continu‐
• For A/T: ous
off not active
• emission • Or
threshold
misfire rate • Number of fade
(MR) > 1.10 out cylinders <
% 3.00 [-]
• For DT/C: • And
• emission • Dynamic mani‐
threshold fold air pressure
misfire rate <= n.a. kPa
(MR) > 1.10
% • Dynamic throttle
position <= n.a.°
• For CV/T: TPS/s
• emission • And
threshold
misfire rate • Engine n.a.
(MR) >
2,184.50 % • Engine speed <
n.a. RPM
• For M/T:
• Dynamic of igni‐
• emission tion angle <=
threshold n.a.° CRK
misfire rate
(MR) > • Or
2,184.50 % • Dynamic of igni‐
tion angle <=
n.a.° CRK
• And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • 4x • 2 DCY
threshold 1,000
misfire with‐ revolu‐
in 4,000 rev tions
• For A/T: • Continu‐
ous
• emission
threshold
misfire rate
(MR) > 1.10
[%]
• For DC/T:
• emission
threshold
misfire rate
(MR) > 1.10
[%]
• For CV/T:
• emission
threshold
misfire rate
(MR) >
2184.50 [%]
• For M/T:
• emission
threshold
misfire rate
(MR) >
2184.50 [%]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0306 Misfire • Catalyst • Initial engine • 200 rev‐ • Immedi‐ – Check the
Cylinder 6 Crank‐ damage speed > 550 olutions ately Cylinder 6
Misfire De‐ shaft misfire for RPM Fuel Injec‐
tected Speed A/T: • Continu‐ tor - N84- .
Fluctua‐ • Engine speed > ous Refer to
tion (Sin‐ • Catalyst 500 RPM ⇒ “3.6.24
gle Or damaging Fuel Injec‐
Multiple) misfire rate • Engine speed <
tors, Check‐
> 0.83 – 6,820 RPM
ing”,
13.89 % • Time after en‐ page 942 .
• For DC/T: gine start > n.a.
s – Check the
• Catalyst Ignition Coil
damaging • And with Power
misfire rate • Output
Depending on
> 0.83 – Stage -
transmission
13.89 % N324- . Re‐
mode for M/T: fer to
• For CV/T: • Engine load > ⇒ “3.6.29
100.0 % Ignition
• Catalyst Coils With
damaging • For A/T: Power Out‐
misfire rate put Stage ,
> 109.23 – • Engine load > Checking”,
1,820.42 % 4.50 – 41.20 % page 952 .
• For M/T: • For CV/T:
– Check the
• Catalyst • Engine load > spark plugs
damaging 97.50 – 103.0 % visually.
misfire rate
> 109.23 – • For DC/T: – Check the
1,820.42 % • pressure in
Engine load >
97.50 – 103.0 % the fuel sys‐
tem for out
• For M/T 4WD: of spec con‐
ditions be‐
• Engine load > fore diag‐
100.0 % nosing the
pressure
• For DC/T 4WD: sensor. Re‐
• Engine load > fer to Fuel
97.50 – 103.0 % System Me‐
chanical
• And Testing in
⇒ “3.1 Pre‐
• Depending on liminary
ECT @ cylinder Check”,
block @ start page 20 .
• ECT @ cylinder
block @ engine
start <= -8° C
• Then activation
if
• ECT @ cylinder
block >= 20° C
• Or
• ECT @ cylinder
block @ engine
start > -8° C
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • Fuel cut off not • 1,000 • 2 DCY
threshold active revolu‐
misfire with‐ • Or tions
in 1,000 rev
• Single fuel cut • Continu‐
• For A/T: ous
off not active
• emission • Or
threshold
misfire rate • Number of fade
(MR) > 1.10 out cylinders <
% 3.00 [-]
• For DT/C: • And
• emission • Dynamic mani‐
threshold fold air pressure
misfire rate <= n.a. kPa
(MR) > 1.10
% • Dynamic throttle
position <= n.a.°
• For CV/T: TPS/s
• emission • And
threshold
misfire rate • Engine n.a.
(MR) >
2,184.50 % • Engine speed <
n.a. RPM
• For M/T:
• Dynamic of igni‐
• emission tion angle <=
threshold n.a.° CRK
misfire rate
(MR) > • Or
2,184.50 % • Dynamic of igni‐
tion angle <=
n.a.° CRK
• And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Emission • 4x • 2 DCY
threshold 1,000
misfire with‐ revolu‐
in 4,000 rev tions
• For A/T: • Continu‐
ous
• emission
threshold
misfire rate
(MR) > 1.10
%
• For DC/T:
• emission
threshold
misfire rate
(MR) > 1.10
%
• For CV/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
• For M/T:
• emission
threshold
misfire rate
(MR) >
2,184.50 %
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0331 Knock • Difference • ECT @ cylinder • 4.3 s • 2 DCY – Check the
Knock/ Sensor 2 between block > 65° C Knock Sen‐
Combus‐ Rationali‐ knock sen‐ • Continu‐ sor 2 -
tion Vibra‐ ty Check sor signal • MAF > 354.0 ous G66- . Refer
tion Sen‐ Low and aver‐ mg/rev to
sor 2 Cir‐ age knock ⇒ “3.6.35
cuit sensor sig‐ Knock Sen‐
Range/ nal < 0.00 – sor 2 G66 ,
Perform‐ 0.14 V Checking”,
ance Bank page 964 .
2
P0332 Knock • Sensor sig‐ • ECT @ cylinder • 4.0 s • 2 DCY – Check the
Knock/ Sensor 2 nal < 0.12 – block > 65° C Knock Sen‐
Combus‐ Out Of 0.27 V • Continu‐ sor 2 -
tion Vibra‐ Range • MAF > 354.0 ous G66- . Refer
tion Sen‐ mg/rev to
sor 2 Cir‐ • Engine speed > ⇒ “3.6.35
cuit Low 1,760 RPM Knock Sen‐
Bank 2 sor 2 G66 ,
Checking”,
page 964 .
P0335 Crank‐ • Counted • Signal edges @ • 0.01 s • 2 DCY – Check the
Crank‐ shaft Po‐ exhaust selected cam‐ Engine
shaft Posi‐ sition camshaft shaft signal de‐ • Continu‐ Speed Sen‐
tion Sen‐ Sensor signals tected ous sor - G28- .
sor "A" Cir‐ Activity without syn‐ Refer to
cuit Check chroniza‐ • Choice of: ⇒ “3.6.18
tion >= 17.0 • Ignition off en‐ Engine
[-] gine speed > Speed Sen‐
192 RPM sor G28 ,
• Or Checking”,
• Counted in‐ • Engine stalling page 930 .
take cam‐ >= 1.0 s
shaft sig‐ • Or
nals without
synchroni‐ • Synchronization
zation >= test incorrect
17.0 [-]
• Or
• Engine speed
>= 192 RPM
• Or
• Engine running
engine stalling
>= 5.0 s
• Or
• Backwards rota‐
tion not detected
• Or
• Engine speed
>= 400 RPM
• Engine stop ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Crank‐ • Pulse width • Engine speed > • 1,800.0°
shaft Po‐ backwards 0.0; < = 3,000 CRK
sition < 62; > 150 RPM
Sensor μs • Continu‐
Out Of ous
Range • For number
of pulse
widths out‐
side toler‐
ance > 1.0
[-]
• Or
• Pulse width
forwards <
15; > 62 μs
• For number
of pulse
widths out‐
side toler‐
ance > 1.0
[-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0336 Engine • Segment • Fuel cut off ac‐ • 120.0° • 2 DCY – Check the
Crank‐ Speed adaptation tive CRK Engine
shaft Posi‐ Sensor >= 0.70 % Speed Sen‐
tion Sen‐ Out Of • Delay time >= • Continu‐ sor - G28- .
sor "A" Cir‐ Range 1,440.0° CRK ous Refer to
cuit • And ⇒ “3.6.18
Range/ Engine
Perform‐ • Diff. actual air Speed Sen‐
ance mass vs. previ‐ sor G28 ,
ous air mass <= Checking”,
20.01 – 39.99 page 930 .
mg/rev
• Engine load <=
20.0 %
• Dynamic throttle
position <=
269.50 –
398.40° TPS/s
• Rough road not
detected
• Diff. between
adapted value of
cylinder 1 and
cylinder 6 < 0.50
%
• Diff. Between
adapted value of
cylinder 4 and
cylinder 2 < 0.50
%
• Diff. between
adapted value of
cylinder 3 and
cylinder 5 < 0.50
%
• Engine speed
2,016 – 5,024
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Counted • Crankshaft syn‐ • 2.0 (con‐
teeth vs. chronization via secutive
reference gap detection start/
>= 1 – <= 2 finished stop cy‐
[-] cle) [-]
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 [s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 [s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Crankshaft • General condi‐ • 2,160.0°
reference tions: CRK
gap not de‐
tected • Reference gap • Continu‐
of reluctor wheel ous
detected
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Counted • General condi‐ • 1,800.0°
teeth vs. tions: CRK
reference
>= 1 – <= 2 • Engine speed > • Continu‐
[-] 320 RPM ous
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0339 Crank‐ • Crankshaft • General condi‐ • 3.0 (con‐ • 2 DCY – Check the
Crank‐ shaft Po‐ reference tions: secutive Engine
shaft Posi‐ sition gap not de‐ start/ Speed Sen‐
tion Sen‐ Sensor tected • Reference gap stop cy‐ sor - G28- .
sor "A" Cir‐ Rationali‐ of reluctor wheel cle) [-] Refer to
cuit Inter‐ ty Check not detected ⇒ “3.6.18
mittent • And Engine
Speed Sen‐
• Case 1: sor G28 ,
Checking”,
• Ignition off page 930 .
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0341 Camshaft • Ratio be‐ • Engine speed • 360.0° • 2 DCY – Check the
Camshaft Position tween 400 – 8,160 CRK Camshaft
Position Sensor measured RPM Position
Sensor "A" Intake segment • Continu‐ Sensor -
Circuit Rationali‐ time ratio ous G40- . Refer
Range/ ty Check and speci‐ to
Perform‐ fied cam‐ ⇒ “3.6.4
ance Bank shaft angle Camshaft
1 or Single ratio > 2.75 Position
Sensor [-] Sensor
G40 ,
• Or Checking”,
• Ratio be‐ page 901 .
tween
measured
segment
time ratio
and speci‐
fied cam‐
shaft angle
ratio < 0.36
[-]
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
< -70.0°
CRK
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0346 Camshaft • Ratio be‐ • Engine speed • 360.0° • 2 DCY – Check the
Camshaft Position tween 400 – 8,160 CRK Camshaft
Position Sensor measured RPM Position
Sensor "A" Intake 2 segment • Continu‐ Sensor 2 -
Circuit Rationali‐ time ratio ous G163- . Re‐
Range/ ty Check and speci‐ fer to
Perform‐ fied cam‐ ⇒ “3.6.5
ance Bank shaft angle Camshaft
2 ratio > 2.75 Position
[-] Sensor 2
G163 ,
• Or Checking”,
• Ratio be‐ page 903 .
tween
measured
segment
time ratio
and speci‐
fied cam‐
shaft angle
ratio < 0.36
[-]
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
< -70.0°
CRK
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
> 19.0°
CRK
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0365 Camshaft • No change • Engine speed • 1,080.0° • 2 DCY – Check the
Camshaft Position on signal >= >= 400 RPM CRK Camshaft
Position Sensor 3 [-] Position
Sensor "B" Exhaust • Continu‐ Sensor 3 -
Circuit Signal ous G300- . Re‐
Bank 1 Activity fer to
Check ⇒ “3.6.6
Camshaft
Position
Sensor 3
G300 ,
Checking”,
page 905 .
P0366 Camshaft • Ratio be‐ • Engine speed • 360.0° • 2 DCY – Check the
Camshaft Position tween 400 – 8,160 CRK Camshaft
Position Sensor measured RPM Position
Sensor "B" Exhaust segment • Continu‐ Sensor 3 -
Circuit Rationali‐ time ratio ous G300- . Re‐
Range/ ty Check and speci‐ fer to
Perform‐ fied cam‐ ⇒ “3.6.6
ance Bank shaft angle Camshaft
1 ratio > 2.75 Position
[-] Sensor 3
G300 ,
• Or Checking”,
• Ratio be‐ page 905 .
tween
measured
segment
time ratio
and speci‐
fied cam‐
shaft angle
ratio < 0.36
[-]
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
< -19.0°
CRK
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
> 60.0°
CRK
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Camshaft • Offset be‐ • Engine synchro‐ • 450.0°
Position/ tween cam‐ nization via CRK
Crank‐ shaft and crankshaft and
shaft Po‐ crankshaft camshaft not fin‐ • Once /
sition Ex‐ < -19.0° ished DCY
haust - CRK
Correla‐ • Or
tion Out • Or
• Engine synchro‐
Of Range • Offset be‐ nization via
tween cam‐ crankshaft and
shaft and camshaft lost
crankshaft
> 60.0°
CRK
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Camshaft • Ratio be‐ • Engine speed • 360.0°
Position tween 400 – 8,160 CRK
Sensor measured RPM
Exhaust segment • Continu‐
2 Ration‐ time ratio ous
ality and speci‐
Check fied cam‐
shaft angle
ratio > 2.75
[-]
• Or
• Ratio be‐
tween
measured
segment
time ratio
and speci‐
fied cam‐
shaft angle
ratio < 0.36
[-]
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
< -19.0°
CRK
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
> 60.0°
CRK
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0413 Secon‐ • Output volt‐ • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air age, lower Secondary
tem Valve range >= • Actuator com‐ • Continu‐ Air Injection
Switching Open Cir‐ 1.92 – 2.21 manded off ous Solenoid
Valve "A" cuit V Valve -
Circuit N112- . Re‐
Open • Output volt‐ fer to
age, upper ⇒ “3.6.43
range Secondary
(hardware Air Injection
values) <= Solenoid
2.85 – 3.25 Valve
V N112 ,
Checking”,
page 984 .
P0414 Secon‐ • Output volt‐ • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air age (hard‐ Secondary
tem Valve ware val‐ • Actuator com‐ • Continu‐ Air Injection
Switching Short To ues) < 1.92 manded off ous Solenoid
Valve "A" Ground – 2.21 V Valve -
Circuit N112- . Re‐
Shorted Secon‐ • Actuator • Engine running fer to
dary Air tempera‐ ⇒ “3.6.43
Valve ture > 160 – • Actuator com‐ Secondary
Short To 200° C manded on Air Injection
Battery Solenoid
Plus • Or Valve
N112 ,
• Output cur‐ Checking”,
rent (hard‐ page 984 .
ware val‐
ues) > 1.0 –
2.0 A
P0418 Secon‐ • Output volt‐ • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air age, lower Secondary
tem Con‐ Injection range 1.92 • Actuator com‐ • Continu‐ Air Injection
trol "A" Cir‐ Pump – 2.21 V manded off ous Pump Re‐
cuit Relay lay - -
Open Cir‐ • Output volt‐ J299-- /
cuit age, upper Secondary
range Air Injection
(hardware Pump Mo‐
values) <= tor - V101- .
2.85 – 3.25 Refer to
V ⇒ “3.6.42
Secondary
Air Injection
Pump Re‐
lay J299 /
Secondary
Air Injection
Pump Mo‐
tor V101 ,
Checking”,
page 982 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0420 Catalyst • Catalyst ef‐ • General condi‐ • 60.0 – • 2 DCY – Check the
Catalyst System ficiency > tions: 70.0 s Oxygen
System Ef‐ NMOG / 1.65 [-] Sensor 1
ficiency NMHC • Vehicle speed • Once / Before Cat‐
Below Conver‐ >= 0 mph DCY alytic Con‐
Threshold sion Ca‐ • BARO >= 63.0 verter -
Bank 1 pability kPa GX10- . Re‐
fer to
• Catalyst over‐ ⇒ “3.6.39
heating protec‐ Oxygen
tion not active Sensor 1
Before Cat‐
• Turbine over‐ alytic Con‐
heating protec‐ verter
tion not equip‐ GX10 ,
ped Checking”,
page 972 .
• O2S rear ready
• O2S front ready – Check the
Oxygen
• ECT @ cylinder Sensor 1
block > 70° C After Cata‐
lytic Con‐
• IAT @ manifold verter -
> -48° C GX7- . Re‐
• Modeled cata‐ fer to
lyst temperature ⇒ “3.6.38
@ start of diag‐ Oxygen
nosis > 550° C Sensor 1
After Cata‐
• Modeled cata‐ lytic Con‐
lyst temperature verter GX7 ,
@ during diag‐ Checking”,
nosis 460 – 990° page 970 .
C
– Check the
• Diff. between Three Way
dynamic and Catalytic
stationary cata‐ Converter
lyst temperature (TWC). Re‐
-292 – 292° C fer to
• Integrated air ⇒ “3.6.44
mass, catalyst Three Way
temp. conditions Catalytic
fulfilled >= 25.0 – Converter
200.0 g (TWC),
Checking”,
• Modeled EGT @ page 986 .
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.0 mg/rev
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a.
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve ( closing
time ) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0430 Catalyst • Catalyst ef‐ • General condi‐ • 60.0 – • 2 DCY – Check the
Catalyst System ficiency > tions: 70.0 s Oxygen
System Ef‐ NMOG / 1.65 [-] Sensor 2
ficiency NMHC • Vehicle speed • Once / Before Cat‐
Below Conver‐ >= 0 mph DCY alytic Con‐
Threshold sion Ca‐ • BARO >= 63.0 verter -
Bank 2 pability kPa GX11- . Re‐
fer to
• Catalyst over‐ ⇒ “3.6.41
heating protec‐ Oxygen
tion not active Sensor 2
Before Cat‐
• Turbine over‐ alytic Con‐
heating protec‐ verter
tion not equip‐ GX11 ,
ped Checking”,
page 978 .
• O2S rear ready
• O2S front ready – Check the
Oxygen
• ECT @ cylinder Sensor 2
block > 70° C After Cata‐
lytic Con‐
• IAT @ manifold verter -
> -48° C GX8- . Re‐
• Modeled cata‐ fer to
lyst temperature ⇒ “3.6.40
@ start of diag‐ Oxygen
nosis > 550° C Sensor 2
After Cata‐
• Modeled cata‐ lytic Con‐
lyst temperature verter GX8 ,
@ during diag‐ Checking”,
nosis 460 – 990° page 976 .
C
– Check the
• Diff. between Three Way
dynamic and Catalytic
stationary cata‐ Converter
lyst temperature (TWC). Re‐
-292 – 292° C fer to
• Integrated air ⇒ “3.6.44
mass, catalyst Three Way
temp. conditions Catalytic
fulfilled >= 25.0 – Converter
200.0 g (TWC),
Checking”,
• Modeled EGT @ page 986 .
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.0 mg/rev
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a.
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve ( closing
time ) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0441 EVAP • Ratio actual • BARO > 73.0 • 8.5 s • 2 DCY – Check the
EVAP Purge intake kPa EVAP Can‐
System In‐ Valve manifold • Once / ister Purge
correct Function‐ pressure • AAT > 4° C DCY Regulator
Purge al Check: and mod‐ • AAT @ start >= Valve 1 -
Flow Stuck eled set 5° C N80- . Refer
Close point intake to
manifold • Diff. barometric ⇒ “3.6.20
pressure < pressure vs. fil‐ EVAP Can‐
0.05 [-] tered intake ister Purge
manifold pres‐ Regulator
sure > n.a. kPa Valve 1
N80 ,
• Diff. barometric Checking”,
pressure vs. fil‐ page 934 .
tered intake
manifold pres‐ – Check the
sure > 25.0 kPa EVAP Sys‐
tem for
• Ratio MAF @ Leaks. Re‐
manifold and fer to
MAF max > 0.15 ⇒
[-] “2.2.4 EVA
• Engine speed P System,
1,150 – 2,500 Checking
RPM for Leaks”,
page 11 .
• Vehicle speed
>= 3 mph
• Diff. engine
speed vs. fil‐
tered engine
speed < 90 RPM
• Diff. ratio MAF
@ manifold and
MAF max vs. ra‐
tio filtered MAF
@ manifold and
MAF max < 0.15
[-]
• Diff. modeled
MAP vs. filtered
modeled MAP <
1.20 kPa
• Fuel cut off not
active
• Diff. engine
speed vs. fil‐
tered engine
speed < 90 RPM
• And
• Integrated air
mass since en‐
gine start >=
5,000.0 –
7,500.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Lambda control
active lambda
control value
-30.0 – 30.0 %
• O2S front 0.90 –
1.10 [-]
• Case 1:
• Integrated air
mass @ canister
purge valve per
driving cycle >=
n.a. g
• Case 2:
• Ratio MAF @
canister purge
and MAF per
cylinder >= 0.0
[-]
• Or
• Canister purge
sampling rate >=
40.0 %
• And
• Integrated air
mass @ canister
purge valve >=
7.1 g
• And
• Depending on
AAT:
• AAT >= 30° C
• Canister load <=
0.20 [-]
• Or
• AAT >= 30; <
50° C
• Canister load <=
0.20 [-]
• Or
• AAT < 30° C
• Canister load <=
0.20 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0444 EVAP • Output volt‐ • Engine start not • 2.0 s • 2 DCY – Check the
EVAP Purge age, lower active EVAP Can‐
System Valve range >= • Continu‐ ister Purge
Purge Open Cir‐ 1.92 – 2.21 • Engine running ous Regulator
Control cuit V • Evap purge Valve 1 -
Valve "A" valve opening N80- . Refer
Circuit • Output volt‐ to
age, upper signal (PWM) >
Open 3.13; <= 98.83 ⇒ “3.6.20
range EVAP Can‐
(hardware %
ister Purge
values) <= • Actuator com‐ Regulator
2.85 – 3.25 manded off Valve 1
V N80 ,
Checking”,
page 934 .
P0445 EVAP • Output volt‐ • Engine start not • 2.0 s • 2 DCY – Check the
EVAP Purge age (hard‐ active EVAP Can‐
System Valve ware val‐ • Continu‐ ister Purge
Purge Short To ues) 1.92 – • Engine running ous Regulator
Control Ground 2.21 V • Evap purge Valve 1 -
Valve "A" valve opening N80- . Refer
Circuit signal (PWM) <= to
Shorted 98.83 % ⇒ “3.6.20
EVAP Can‐
• Actuator com‐ ister Purge
manded off Regulator
Valve 1
EVAP • Actuator • Engine start not N80 ,
Purge tempera‐ active Checking”,
Valve ture 160 – page 934 .
Short To 200° C • Engine running
Battery • Evap purge
Plus • Or
valve opening
• Output cur‐ signal (PWM) >=
rent (hard‐ 3.13 %
ware val‐
ues) > 4.0 – • Actuator com‐
7.0 A manded off
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0450 Smart • Signal volt‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Tempera‐ age 0.39 to EVAP Can‐
System ture Sen‐ 0.55 V • Engine running • Continu‐ ister Purge
Pressure sor Open ous Regulator
• Case 2:
Sensor/ Circuit Valve 1 -
Switch Cir‐ • Ignition off N80- . Refer
cuit to
• NVLD (EVAP ⇒ “3.6.20
system) diag‐ EVAP Can‐
nostic mode ac‐ ister Purge
tive Regulator
Valve 1
N80 ,
Checking”,
page 934 .
– Check the
Fuel Tank
Leak Detec‐
tion Control
Module -
J909- . Re‐
fer to
⇒ “3.6.28
Fuel Tank
Leak Detec‐
tion Control
Module
J909 ,
Checking”,
page 950 .
– Check the
EVAP Sys‐
tem for
Leaks. Re‐
fer to
⇒
“2.2.4 EVA
P System,
Checking
for Leaks”,
page 11 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0451 NVLD • Natural vac‐ • Ignition off • 35.0 s • 2 DCY – Check the
EVAP Switch uum leak EVAP Can‐
System Function‐ detection • Fuel level < • Once / ister Purge
Pressure al Check: (NVLD) 85.10% DCY Regulator
Sensor/ Stuck switch posi‐ • Fuel tempera‐ Valve 1 -
Switch Cir‐ Close tion closed ture increase >= N80- . Refer
cuit 5K to
Range/ ⇒ “3.6.20
Perform‐ • For time >= 1.0 h EVAP Can‐
ance ister Purge
• AAT >= 5° C Regulator
Valve 1
• Barometric N80 ,
pressure > Checking”,
73.00 kPa page 934 .
• Time since igni‐
tion off > 20; < – Check the
1,440 min EVAP Sys‐
tem for
Leaks. Re‐
fer to
⇒
“2.2.4 EVA
P System,
Checking
for Leaks”,
page 11 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0452 Smart • Signal volt‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Tempera‐ age < 0.24 EVAP Can‐
System ture Sen‐ V • Engine running • Continu‐ ister Purge
Pressure sor Short ous Regulator
• Case 2:
Sensor/ To Valve 1 -
Switch Cir‐ Ground • Ignition off N80- . Refer
cuit Low to
• NVLD (EVAP ⇒ “3.6.20
system) diag‐ EVAP Can‐
nostic mode ac‐ ister Purge
tive Regulator
Valve 1
N80 ,
Checking”,
page 934 .
– Check the
Fuel Tank
Leak Detec‐
tion Control
Module -
J909- . Re‐
fer to
⇒ “3.6.28
Fuel Tank
Leak Detec‐
tion Control
Module
J909 ,
Checking”,
page 950 .
– Check the
EVAP Sys‐
tem for
Leaks. Re‐
fer to
⇒
“2.2.4 EVA
P System,
Checking
for Leaks”,
page 11 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0453 Smart • Signal volt‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Tempera‐ age > 3.0 V EVAP Can‐
System ture Sen‐ • Engine running • Continu‐ ister Purge
Pressure sor Short ous Regulator
• Case 2:
Sensor/ To Bat‐ Valve 1 -
Switch Cir‐ tery Plus • Ignition off N80- . Refer
cuit High to
• NVLD (EVAP ⇒ “3.6.20
system) diag‐ EVAP Can‐
nostic mode ac‐ ister Purge
tive Regulator
Valve 1
N80 ,
Checking”,
page 934 .
– Check the
Fuel Tank
Leak Detec‐
tion Control
Module -
J909- . Re‐
fer to
⇒ “3.6.28
Fuel Tank
Leak Detec‐
tion Control
Module
J909 ,
Checking”,
page 950 .
– Check the
EVAP Sys‐
tem for
Leaks. Re‐
fer to
⇒
“2.2.4 EVA
P System,
Checking
for Leaks”,
page 11 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0456 EVAP • Natural vac‐ • Ignition off • 0.1 s • 2 DCY – Check the
EVAP System uum leak EVAP Can‐
System Small detection • Fuel level < • Once / ister Purge
Leak De‐ Leak (NVLD) 85.10% DCY Regulator
tected Function‐ switch posi‐ • Fuel tempera‐ Valve 1 -
(Very al Check tion open ture drop >= 6 K N80- . Refer
Small to
Leak) • For time > 1.0 h ⇒ “3.6.20
EVAP Can‐
• AAT >= 5° C ister Purge
Regulator
• Altitude < 2,700 Valve 1
m N80 ,
• Barometric Checking”,
pressure > page 934 .
73.00 kPa
– Check the
• Diff. barometric EVAP Sys‐
pressure @ stop tem for
and barometric Leaks. Re‐
pressure @ start fer to
< 0.65 kPa ⇒
“2.2.4 EVA
• Time since igni‐ P System,
tion off > 90; < Checking
600 min for Leaks”,
page 11 .
P0461 Fuel Lev‐ • Diff. fuel • General: • 1.0 s • 2 DCY – Refer to ap‐
Fuel Level el Plausi‐ consump‐ propriate
Sensor "A" bility tion and fuel • Refueling or de- • Continu‐ wiring dia‐
Circuit Check level fueling not de‐ ous gram. If fuel
Range/ changes < tected level sensor
Perform‐ -25.0; > • And and circuitry
ance 12.0 l are ok, then
• Case 1: For tank replace the
full instrument
cluster. Re‐
• Fuel level > fer to appro‐
96.09 % priate repair
manual.
• Fuel consump‐
tion since last re‐
fueling or last
plausibility
check > 44.0 l
• Case 2: for tank
not full
• Fuel level <=
96.09 %
• Fuel consump‐
tion since last re‐
fueling or last
plausibility
check > 15.0 l
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Cluster • Instrument instrument
Module cluster cluster. Re‐
module sig‐ fer to appro‐
nal: signal priate repair
range manual.
check fail‐
ure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0491 Secon‐ • Case 1: • ECT @ cylinder • 0.2 s • 2 DCY – Check the
AIR Sys‐ dary Air block @ engine Secondary
tem Insuf‐ System • Deviation start 5 – 50° C • Once / Air Injection
ficient Flow lambda DCY Pump Re‐
Flow Bank Check controller • AAT @ engine lay - -
1 During output > start >= 5° C J299-- /
Catalyst n.a. % Secondary
• Time after en‐
Heating • Relative gine start >= Air Injection
diff. mod‐ 22.0 – 120.0 s Pump Mo‐
eled secon‐ tor - V101- .
dary mass • Fuel cut off not Refer to
air flow vs. active ⇒ “3.6.42
actual sec‐ • Secondary
O2S front ready Air Injection
ondary
mass air Pump Re‐
• MAF <=
flow > n.a. lay J299 /
2,047.97 kg/h
[-] Secondary
• Air mass (en‐ Air Injection
• For time >= gine load), lower Pump Mo‐
n.a. s range >= 0.0 – tor V101 ,
82.0 mg/rev Checking”,
• Or page 982 .
• Air mass (en‐
• Case 2: gine load), up‐ – Check the
• Ratio mod‐ per range <= combina‐
eled secon‐ 452.0 mg/rev tion valve
dary mass • for secon‐
Engine speed, dary air in‐
air flow and lower range >=
measured jection. Re‐
800 – 8,160 fer to appro‐
secondary RPM
mass air priate repair
flow < 30.0 • Engine speed, manual.
% upper range <=
3,008 RPM
• Additional mass
fuel flow for wall
fuel liquid film
-6.0 – 6.0 mg/rev
• O2S front > 2.0
[-]
• Modeled pres‐
sure quotient <=
1.0 [-]
• AIR system
commanded on
• Low dynamic
conditions
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 220
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 110.0 mg/
rev
• Diff. lambda vs.
averaged lamb‐
da for lambda
dynamic detec‐
tion < 1.10 [-]
• Integrated MAF
> 10.0
• Catalyst heating
active
• Secondary air
injection active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0492 Secon‐ • Case 1: • ECT @ cylinder • 0.2 s • 2 DCY – Check the
AIR Sys‐ dary Air block @ engine Secondary
tem Insuf‐ System 2 • Deviation start 5 – 50° C • Once / Air Injection
ficient Flow lambda DCY Pump Re‐
Flow Bank Check controller • AAT @ engine lay - -
2 During output > start >= 5° C J299-- /
Catalyst n.a. % Secondary
• Time after en‐
Heating • Relative gine start >= Air Injection
diff. mod‐ 22.0 – 120.0 s Pump Mo‐
eled secon‐ tor - V101- .
dary mass • Fuel cut off not Refer to
air flow vs. active ⇒ “3.6.42
actual sec‐ • Secondary
O2S front ready Air Injection
ondary
mass air Pump Re‐
• MAF <=
flow > n.a. lay J299 /
2,047.97 kg/h
[-] Secondary
• Air mass (en‐ Air Injection
• For time >= gine load), lower Pump Mo‐
n.a. s range >= 0.0 – tor V101 ,
82.0 mg/rev Checking”,
• Or page 982 .
• Air mass (en‐
• Case 2: gine load), up‐ – Check the
• Ratio mod‐ per range <= Combina‐
eled secon‐ 452.0 mg/rev tion valve
dary mass • for secon‐
Engine speed, dary air in‐
air flow and lower range >=
measured jection. Re‐
800 – 8,160 fer to appro‐
secondary RPM
mass air priate repair
flow < 30.0 • Engine speed, manual.
% upper range <=
3,008 RPM
• Additional mass
fuel flow for wall
fuel liquid film
-6.0 – 6.0 mg/rev
• O2S front > 2.00
[-]
• Modeled pres‐
sure quotient <=
1.00 [-]
• AIR system
commanded on
• Low dynamic
conditions
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 220
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 110.0 mg/
rev
• Diff. lambda vs.
averaged lamb‐
da for lambda
dynamic detec‐
tion < 1.10 [-]
• Integrated MAF
> 10.0 g
• Catalyst heating
active
• Secondary air
injection active
P0501 Vehicle • Vehicle • Time after igni‐ • 10.1 s • 2 DCY – Check the
Vehicle Speed speed < 1 tion on > 500.0 vehicle
Speed Rationali‐ mph ms • Continu‐ speed sig‐
Sensor "A" ty Check: ous nal. Refer to
Circuit Stuck • Fuel cut off ac‐ ⇒ “3.6.47
Range/ Sensor tive Vehicle
Perform‐ Signal • For time > 12.0 s Speed Sig‐
ance nal, Check‐
ing”,
CAN: Ve‐ • Speed sen‐ • 0.5 s page 992 .
hicle sor fault val‐
Speed ue: Out of • Continu‐
Sensor range high ous
CAN failure
Commu‐
nication • Speed sen‐
With Ve‐ sor fault val‐
hicle ue: Out of
Speed range low
Sensor failure
• Speed sen‐
sor fault val‐
ue: Ration‐
ality check
high failure
• Speed sen‐
sor fault val‐
ue: Ration‐
ality check
low failure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0506 Idle Con‐ • Diff. actual • General condi‐ • 7.0 s • 2 DCY – Check the
Idle Con‐ troller engine tions: Throttle
trol Sys‐ Function speed vs. • Continu‐ Valve Con‐
tem RPM - Monitor‐ engine • Vehicle speed = ous trol Module
Lower ing: En‐ speed set 0 mph - GX3- . Re‐
Than Ex‐ gine point < 100 • Accelerator ped‐ fer to
pected Speed RPM al released by ⇒ “3.6.45
Deviation driver Throttle
• Integrated I- Valve Con‐
part of idle • Throttle actuator trol Module
speed con‐ commanded on GX3 ,
troller n.a. Checking”,
• Evap purge flow page 987 .
< 4.0 kg/h
• Engine running
• Time after en‐
gine start > 5.0 –
25.4 s
• Clutch switch
n.a.
• Barometric
pressure > 63.0
kPa
• Catalyst heating
not active
• ECT @ cylinder
block > -9° C
• And
• Set point
change < n.a.
RPM
• For time >= n.a.
s
• And
• Additional after
dynamic condi‐
tions fulfilled:
• Gear switch not
active (automat‐
ic transmission
only)
• Accelerator ped‐
al released by
driver
• Vehicle speed 0
mph
• Engine load <
100.0 % (man‐
ual transmission
only)
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0507 Idle Con‐ • Diff. actual • General condi‐ • 7.0 s • 2 DCY – Check the
Idle Con‐ troller engine tions: Throttle
trol Sys‐ Function speed vs. • Continu‐ Valve Con‐
tem RPM - Monitor‐ engine • Vehicle speed = ous trol Module
Higher ing: En‐ speed set 0 mph - GX3- . Re‐
Than Ex‐ gine point > 200 • Accelerator ped‐ fer to
pected Speed RPM al released by ⇒ “3.6.45
Deviation driver Throttle
• Integrated I- Valve Con‐
part of idle • Throttle actuator trol Module
speed con‐ commanded on GX3 ,
troller n.a. Checking”,
• Evap purge flow page 987 .
< 4.0 kg/h
• Engine running
• Time after en‐
gine start > 5.0 –
25.4 s
• Clutch switch
n.a.
• Barometric
pressure > 63.0
kPa
• Catalyst heating
not active
• ECT @ cylinder
block > -9° C
• And
• Set point
change < n.a.
RPM
• For time >= n.a.
s
• And
• Additional after
dynamic condi‐
tions fulfilled:
• Gear switch not
active (automat‐
ic transmission
only)
• Accelerator ped‐
al released by
driver
• Vehicle speed 0
mph
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P050A Cold • Diff. actual • General condi‐ • 7.0 s • 2 DCY – Check the
Cold Start Start engine tions: Throttle
Idle Con‐ Monitor‐ speed vs. • Continu‐ Valve Con‐
trol Sys‐ ing Idle engine • Vehicle speed = ous trol Module
tem Per‐ Controller speed set 0 mph - GX3- . Re‐
formance Function point > 200 • Accelerator ped‐ fer to
Monitor‐ RPM al released by ⇒ “3.6.45
ing: En‐ driver Throttle
gine • Integrated I- Valve Con‐
Speed part of idle • Driver request trol Module
Deviation speed con‐ not active GX3 ,
troller n.a. Checking”,
• Throttle actuator page 987 .
commanded on
• Evap purge flow
< 4.0 kg/h
• Engine running
• Time after en‐
gine start > 5.0 –
25.4 s
• Clutch switch
n.a.
• Barometric
pressure > 63.0
kPa
• Catalyst heating
active
• ECT @ cylinder
block > -9° C
• And
• Set point
change < n.a.
RPM
• For time >= n.a.
s
• And
• Additional after
dynamic condi‐
tions fulfilled:
• Gear switch not
active (automat‐
ic transmission
only)
• Accelerator ped‐
al released by
driver
• Vehicle speed 0
mph
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. actual • General condi‐
engine tions:
speed vs.
engine • Vehicle speed =
speed set 0 mph
point < -100 • Accelerator ped‐
– -150 RPM al released by
• Integrated I- driver
part of idle • Throttle actuator
speed con‐ commanded on
troller n.a.
• Evap purge flow
< 4.0 kg/h
• Engine running
• Time after en‐
gine start > 5.0 –
25.4 s
• Clutch switch
n.a.
• Barometric
pressure > 63.0
kPa
• Catalyst heating
active
• ECT @ cylinder
block > -9° C
• And
• Set point
change < n.a.
RPM
• For time >= n.a.
s
• And
• Additional after
dynamic condi‐
tions fulfilled:
• Gear switch not
active (automat‐
ic transmission
only)
• Accelerator ped‐
al released by
driver
• Vehicle speed 0
mph
• Engine load <
100.0 % (man‐
ual transmission
only)
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P050B Ignition • Ratio be‐ • Engine idle • 0.1 s • 2 DCY – Check the
Cold Start Control tween igni‐ speed Throttle
Ignition Ignition tion angle • Once / Valve Con‐
Timing Timing efficiency • Time @ idle DCY trol Module
Perform‐ Monitor integral and speed > 5.0 s - GX3- . Re‐
ance time at idle • Ignition angle fer to
speed > set point <= 0.77 ⇒ “3.6.45
0.20 – 0.30 [-] Throttle
[-] Valve Con‐
• Modeled pres‐ trol Module
sure quotient <= GX3 ,
0.73 – 0.82 [-] Checking”,
page 987 .
• Vehicle speed
=0 mph
• And
• Diff. air mass set
point vs. filtered
air mass set
point for load dy‐
namic detection
< 1,389.0 mg/
rev
• For time >= 0.4 s
• And
• Diff. engine
speed vs. fil‐
tered engine
speed for engine
speed dynamic
detection < 200
RPM
• For time >= 0.6 s
P052A Cold • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
Cold Start Start position de‐ perature 15 – (FTP75: Camshaft
"A" Cam‐ Monitor‐ viation > 130° C 45.0) s Position
shaft Posi‐ ing VVT 10.0° CRK Sensor -
tion Timing Actuator • Engine speed • Once / G40- . Refer
Over-Ad‐ Intake 608 – 7,008 DCY to
vanced Rationali‐ RPM ⇒ “3.6.4
Bank 1 ty Check • Camshaft posi‐ Camshaft
tion not @ max. Position
stop position Sensor
G40 ,
• Camshaft posi‐ Checking”,
tion adjustment page 901 .
active
• Catalyst heating
active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 40.0°
CRK * s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P052C Cold • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
Cold Start Start position de‐ perature 15 – (FTP75: Camshaft
"A" Cam‐ Monitor‐ viation > 130° C 45.0) s Position
shaft Posi‐ ing VVT 10.0° CRK Sensor 2 -
tion Timing Actuator • Engine speed • Once / G163- . Re‐
Over-Ad‐ Intake 608 – 7,008 DCY fer to
vanced Bank 2 RPM ⇒ “3.6.5
Bank 2 Rationali‐ • Camshaft posi‐ Camshaft
ty Check tion not @ max. Position
stop position Sensor 2
G163 ,
• Camshaft posi‐ Checking”,
tion adjustment page 903 .
active
• Catalyst heating
active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 40.0°
CRK * s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Cold • Deviation • Time after en‐
Start between set gine start > 3.0 s
Monitor‐ point and
actual fuel • Fuel mass set
ing Fuel point lower
System pressure > range >= 8.50
Out Of 1,500.20 mg/rev
Range kPa
Low
• For time >= • For time >= 3.0 s
5.0 s
P054A Cold • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
Cold Start Start position de‐ perature 15 – (FTP75: Camshaft
"B" Cam‐ Monitor‐ viation > 130° C 45.0) s Position
shaft Posi‐ ing VVT 10.0° CRK Sensor 3 -
tion Timing Actuator • Engine speed • Once / G300- . Re‐
Over-Ad‐ Outlet 608 – 7,008 DCY fer to
vanced Rationali‐ RPM ⇒ “3.6.6
Bank 1 ty Check • Camshaft posi‐ Camshaft
tion not @ max. Position
stop position Sensor 3
G300 ,
• Camshaft posi‐ Checking”,
tion adjustment page 905 .
active
• Catalyst heating
active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 40.0°
CRK * s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P054C Cold • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
Cold Start Start position de‐ perature 15 – (FTP75: Camshaft
"B" Cam‐ Monitor‐ viation > 130° C 45.0) s Position
shaft Posi‐ ing VVT 10.0° CRK Sensor 4 -
tion Timing Actuator • Engine speed • Once / G301- . Re‐
Over-Ad‐ Outlet 608 – 7,008 DCY fer to
vanced Bank 2 RPM ⇒ “3.6.7
Bank 2 Rationali‐ • Camshaft posi‐ Camshaft
ty Check tion not @ max. Position
stop position Sensor 4
G301 ,
• Camshaft posi‐ Checking”,
tion adjustment page 908 .
active
• Catalyst heating
active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 40.0°
CRK * s
– Replace the
Transmis‐
sion Control
Module -
J217- . Re‐
fer to appro‐
priate repair
manual.
P0603 ECM • Device 1: • 2.0 s • 2 DCY – Replace the
Internal Commu‐ faulty En‐
Control nication • SPI com‐ • Continu‐ gine Control
Module Check munication ous Module .
Keep Alive with ATIC Refer to ap‐
Memory failure propriate
(KAM) Er‐ repair man‐
ror • Device 2: ual.
• SPI com‐ – Replace the
munication Transmis‐
with ATIC sion Control
failure Module -
J217- . Re‐
• SPI com‐ fer to appro‐
munication priate repair
with ATIC manual.
failure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
ECM: In‐ • Hardware • 0.2 s
jection vs. software
Valves version • Once /
Internal check dur‐ DCY
Hardware ing initiali‐
Check zation fail‐
ure
• Calibration
during initi‐
alization
failure
• Hardware
during initi‐
alization
failure
• Time refer‐
ence from
micro con‐
troller dur‐
ing initiali‐
zation fail‐
ure
• Communi‐ • 2,880.0°
cation be‐ CRK
tween micro
controller • Continu‐
and SDI- ous
Driver pow‐
er stage fail‐ • 360.0°
ure CRK
• Once /
DCY
• Communi‐ • 4,320.0°
cation be‐ CRK
tween micro
controller • Continu‐
and SDI- ous
Driver pow‐
er stage
failed
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0606 Baromet‐ • Engine_stand‐ • Engine stopped • 3.0 s • 2 DCY – Replace the
Control ric Pres‐ ing: faulty En‐
Module sure Sen‐ • Vehicle speed < • Continu‐ gine Control
Processor sor Cross • Diff. pressure 1 mph ous Module .
Check downstream Refer to ap‐
throttle vs. • Engine @ driv‐
propriate
barometric ing cycle not
started the first repair man‐
pressure >= ual.
7.0 kPa time
• Diff. baromet‐
ric pressure
vs. manifold
pressure >=
7.0 kPa
• Or
• Diff. pressure
downstream
throttle vs.
barometric
pressure >=
7.0 kPa
• Diff. baromet‐
ric pressure
vs. manifold
pressure 2 >=
7.0 kPa
• Or
• Diff. baromet‐
ric pressure
vs. manifold
pressure >=
7.0 kPa
• Diff. baromet‐
ric pressure
vs. manifold
pressure 2 >=
7.0 kPa
• Or
• Diff. pressure
downstream
throttle vs.
barometric
pressure >=
7.0 kPa
• Diff. deviation
BARO to
mean value
(MAP 2 and
MAP) vs. devi‐
ation pressure
downstream
throttle to
mean value
(MAP 2 and
MAP) > 0 kPa
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. baromet‐
ric pressure
vs. manifold
pressure >=
7.0 kPa
• Diff. deviation
BARO to
mean value
(MAP 2 and
pressure
downstream
throttle) vs.
deviation MAP
to mean value
(MAP 2 and
pressure
downstream
throttle) > 0
kPa
• Or
• Diff. baromet‐
ric pressure
vs. manifold
pressure 2 >=
7.0 kPa
• Diff. deviation
BARO to
mean value
(MAP and
pressure
downstream
throttle) vs.
deviation MAP
2 to mean val‐
ue (MAP and
pressure
downstream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• During • Engine stopped
ECM keep
alive-time:
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.0 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.0 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.0 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐ • Vehicle speed <
tion BARO 1 mph
to mean val‐
ue (MAP 2 • ECM keep alive
and MAP) time > 10.0 s
vs. devia‐ • Time after en‐
tion pres‐ gine stop >= 4.0
sure down‐ s
stream
throttle to • Barometric
mean value pressure 55.0 –
(MAP 2 and 110.0 kPa
MAP) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.0 kPa
• Diff. devia‐
tion BARO
to mean val‐
ue (MAP 2
and pres‐
sure down‐
stream
throttle) vs.
deviation
MAP to
mean value
(MAP 2 and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.0 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. devia‐
tion BARO
to mean val‐
ue (MAP
and pres‐
sure down‐
stream
throttle) vs.
deviation
MAP 2 to
mean value
(MAP and
pressure
down‐
stream
throttle) > 0
kPa
• Sensor cell
failure
• Finished
NVMCrypt
integrity er‐
ror
• Communi‐
cation be‐
tween sam‐
ple software
and produc‐
tion hard‐
ware error
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
ECM: • Monitoring • 0.5 s
Random module
Access check failed • Continu‐
Memory ous
(RAM)
Function‐
al Check
ECM: • SPI com‐ • Time after igni‐ • 10.0 s
Commu‐ munication tion on >= 1.0 s
nication with ATIC • Continu‐
Check failed ous
• SPI com‐
munication
with ATIC
implausible
• Monitoring • 0.01 s
of torque
difference • Continu‐
integration ous
integrated
engine tor‐
que >
655.35 Nms
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Cold • Ratio of in‐ • General condi‐ • 120.0°
Start jection fault tions: CRK
Monitor‐ counter and
ing ECM: number of • Engine running • Continu‐
Dual In‐ requested • ous
Injection on all
jection injections > cylinders active
Rationali‐ 0.13 [-] MFI and DFI ac‐
ty Check tive
• Conditions for
measurement
window:
• Catalyst heating
active
• Conditions at
fault decision:
• Catalyst heating
finished
• Requested in‐
jections > 300.0
[-]
P0638 Throttle • Battery volt‐ • Throttle adapta‐ • 0.01 s • 2 DCY – Check the
Throttle Actuator age <= 7.92 tion (@ initial Throttle
Actuator Basic V start or after de‐ • Once Valve Con‐
Control Settings tection of throttle per life‐ trol Module
Range/ Adapta‐ • Accelerator exchange or time - GX3- . Re‐
Perform‐ tion Val‐ pedal value checksum error) fer to
ance Bank ue Moni‐ > 99.90 % active ⇒ “3.6.45
1 toring Throttle
• Or Valve Con‐
trol Module
• Engine GX3 ,
speed > 64 Checking”,
RPM page 987 .
• Or
• Vehicle
speed > 2
mph
• Or
• IAT @ throt‐
tle < 6° C
• Or
• ECT @ cyl‐
inder block
< 6° C
• Or
• ECT @ cyl‐
inder block
> 105° C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Throttle • Actual TPS • Throttle adapta‐
Actuator - ref. point > tion demanded
Basic 0.197° TPS
Settings • Accelerator ped‐
Monitor‐ al value < 99.90
ing Of Po‐ %
sition • Engine speed <
64 RPM
• Vehicle speed <
2 mph
• IAT @ throttle >
6° C
• ECT @ cylinder
block 6 – 105° C
• Or • Accelerator ped‐
al value < 99.90
• Throttle po‐ %
sition sen‐
sor 2 volt‐ • Vehicle speed <
age > 4.60 2 mph
V • IAT @ throttle >
• Or 6° C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Actual TPS
1 or 2 volt‐
age - volt‐
age ref.
point > 0.07
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0652 ECM: 5V • Analog out‐ • 0.2 s • 2 DCY – Replace the
Sensor Supply put 2 supply faulty En‐
Reference Voltage voltage < • Continu‐ gine Control
Voltage Out Of 4.62 V ous Module .
"B" Circuit Range Refer to ap‐
Low Low propriate
repair man‐
ual.
P0653 ECM: 5V • Analog out‐ • 0.2 s • 2 DCY – Replace the
Sensor Supply put 2 supply faulty En‐
Reference Voltage voltage > • Continu‐ gine Control
Voltage Out Of 5.43 V ous Module .
"B" Circuit Range Refer to ap‐
High High propriate
repair man‐
ual.
P0657 Supply • Output volt‐ • Relay comman‐ • 1.5 s • 2 DCY – Check the
Actuator Voltage age lower ded off Motronic
Supply Relay En‐ range >= • Continu‐ Engine
Voltage gine 1.90 – 2.30 ous Control
"A" Circuit/ Compo‐ V Module
Open nents Power Sup‐
Open Cir‐ • Output volt‐ ply Relay -
cuit age upper J271- . Re‐
range fer to
(hardware ⇒ “3.6.37
values) <= Motronic
2.80 – 3.20 Engine
V Control
Module
Power Sup‐
ply Relay
J271 ,
Checking”,
page 967 .
P0658 Supply • Output volt‐ • Relay comman‐ • 1.5 s • 2 DCY – Check the
Actuator Voltage age (hard‐ ded off Motronic
Supply Relay En‐ ware val‐ • Continu‐ Engine
Voltage gine ues) < 1.90 ous Control
"A" Circuit Compo‐ – 2.28 V Module
Low nents Power Sup‐
Short To ply Relay -
Ground J271- . Re‐
fer to
⇒ “3.6.37
Motronic
Engine
Control
Module
Power Sup‐
ply Relay
J271 ,
Checking”,
page 967 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0659 Supply • Output cur‐ • Relay comman‐ • 1.5 s • 2 DCY – Check the
Actuator Voltage rent > 1.0 – ded on Motronic
Supply Relay En‐ 2.3 A • Continu‐ Engine
Voltage gine ous Control
"A" Circuit Compo‐ • Or Module
High nents • Actuator Power Sup‐
Short To tempera‐ ply Relay -
Battery ture (hard‐ J271- . Re‐
Plus ware val‐ fer to
ues) > 175 – ⇒ “3.6.37
195° C Motronic
Engine
Control
Module
Power Sup‐
ply Relay
J271 ,
Checking”,
page 967 .
P0686 Main Re‐ • Sensed cir‐ • Main relay com‐ • 0.1 s • 2 DCY – Check the
ECM/PCM lay Ra‐ cuit voltage manded off Motronic
Power Re‐ tionality > 6.0 V • Continu‐ Engine
lay Control Check • For time >= 0.3 s ous Control
Circuit During Module
Low Engine Power Sup‐
Off ply Relay -
J271- . Re‐
fer to
⇒ “3.6.37
Motronic
Engine
Control
Module
Power Sup‐
ply Relay
J271 ,
Checking”,
page 967 .
P0687 Main Re‐ • Sensed cir‐ • Main relay com‐ • 0.1 s • 2 DCY – Check the
ECM/PCM lay Ra‐ cuit voltage manded on Motronic
Power Re‐ tionality < 5.0 V • Continu‐ Engine
lay Control Check • for time >= 0.1 s ous Control
Circuit During Module
High Engine Power Sup‐
Off ply Relay -
Main Re‐ • Main relay • Main relay com‐ • 0.2 s J271- . Re‐
lay Short driver tem‐ manded on fer to
To Bat‐ perature > • Continu‐ ⇒ “3.6.37
tery Plus 175 – 195° • For time >= 0.4 s ous Motronic
C Engine
Control
• Or Module
Power Sup‐
• Main relay ply Relay
output cur‐ J271 ,
rent (hard‐ Checking”,
ware val‐ page 967 .
ues) > 1.0 –
2.3 A
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P0698 ECM: 5V • Analog out‐ • 0.2 s • 2 DCY – Replace the
Sensor Supply put 3 supply faulty En‐
Reference Voltage voltage < • Continu‐ gine Control
Voltage Out Of 4.62 V ous Module .
"C" Circuit Range Refer to ap‐
Low Low propriate
repair man‐
ual.
P0699 ECM: 5V • Analog out‐ • 0.2 s • 2 DCY – Replace the
Sensor Supply put 3 supply faulty En‐
Reference Voltage voltage > • Continu‐ gine Control
Voltage Out Of 5.43 V ous Module .
"C" Circuit Range Refer to ap‐
High High propriate
repair man‐
ual.
P10A0 Super‐ • Recircula‐ • 0.5 s • 2 DCY – Check the
Actuation charger tion flap out‐ Control
Regulating Bypass put current • Continu‐ Valve Con‐
Flap For Short Cir‐ > 9.3 – 15.0 ous trol Unit -
Intake Air cuit A J808- . Re‐
Electrical fer to
Error Super‐ • Duty cycle > • Recirculation ⇒ “3.6.13
charger 95.0 % flap position Control
Bypass adaptation not Valve Con‐
Out Of • Or active trol Unit
Range J808 ,
• Duty cycle < Checking”,
-95.0 % page 920 .
P10A1 Super‐ • Recircula‐ • Negative PWM • 0.5 s • 2 DCY – Check the
Actuation charger tion flap out‐ signal Control
Regulating Bypass put current • Continu‐ Valve Con‐
Flap For Short To (high side ) • Positive PWM ous trol Unit -
Intake Air Battery > 9.3 – 15.0 signal J808- . Re‐
Short Cir‐ A fer to
cuit To B+ ⇒ “3.6.13
Control
Valve Con‐
trol Unit
J808 ,
Checking”,
page 920 .
P10A2 Super‐ • Recircula‐ • Positive PWM • 0.5 s • 2 DCY – Check the
Actuation charger tion flap out‐ signal Control
Regulating Bypass put current • Continu‐ Valve Con‐
Flap For Short To (low side ) > • Negative PWM ous trol Unit -
Intake Air Ground 9.3 – 15.0 A signal J808- . Re‐
Short Cir‐ fer to
cuit To ⇒ “3.6.13
Ground Control
Valve Con‐
trol Unit
J808 ,
Checking”,
page 920 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P10A3 Super‐ • Electronic • Power stage de‐ • 0.2 s • 2 DCY – Check the
Actuation charger recircula‐ activation active Control
Regulating Bypass tion flap • Continu‐ Valve Con‐
Flap For Open Cir‐ driver load • And ous trol Unit -
Intake Air cuit resistance > • Diff. filtered val‐ J808- . Re‐
Open Cir‐ 200.0 ue of recircula‐ fer to
cuit kOhm tion flap position ⇒ “3.6.13
vs. actual recir‐ Control
culation flap po‐ Valve Con‐
sition < 1.00° trol Unit
J808 ,
• For time >= 0.1 s Checking”,
page 920 .
P10A4 Super‐ • Limp home • General condi‐ • 0.0 s • 2 DCY – Check the
Regulating charger position < tions: based Control
Flap For Bypass 60.01° on event Valve Con‐
Intake Air Adapta‐ • ECT @ cylinder trol Unit -
Mechani‐ tion Val‐ • Or block >= 5° C • Once / J808- . Re‐
cal Mal‐ ue Moni‐ • DCY fer to
Limp home • IAT @ manifold
function toring position > >= 5° C ⇒ “3.6.13
(Top Lim‐ 88.0° Control
it / Bottom • ECM keep alive Valve Con‐
Limit) time active trol Unit
J808 ,
• Time after igni‐ Checking”,
tion on > 2.6 s page 920 .
Super‐ • After • General condi‐ • 0.01 s
charger changed tions:
Bypass limp home • Once /
Adapta‐ position: • Vehicle speed 0 DCY
tion Val‐ mph
ue Moni‐ • Limp home
• Engine speed
toring position <
60.01° <= 64 RPM
(Top Lim‐
it / Bottom • Or • ECT @ cylinder
Limit) block 6 – 105° C
• Limp home
position > • IAT @ manifold
88.0° >= 6° C
• Time after igni‐
tion on > 2.6 s
• Depending on
stored limp
home position:
• Stored sensor
voltage @ lower
mechanical stop
< 0.35 V
• Or
• Stored sensor
voltage @ lower
mechanical stop
> 0.65 V
• Or
• Limp home posi‐
tion change de‐
tected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Super‐ • Diff. actual • General condi‐
charger recircula‐ tions:
Bypass tion flap po‐
Adapta‐ sition vs. • ECT @ cylinder
tion Val‐ adapted set block >= 5° C
ue Moni‐ point recir‐ • IAT @ manifold
toring culation flap >= 5° C
(Top Lim‐ position >
it / Bottom 1.0° • ECM keep alive
Limit) time active
• Or
• Time after igni‐
• Diff. adap‐ tion on > 2.6 s
ted limp
home posi‐
tion vs. ac‐
tual position
of recircula‐
tion flap >=
1.0°
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P10A7 Super‐ • Limp home • 0.01 s • 2 DCY – Check the
Adaptation charger position Control
Regulating Bypass change de‐ • Once / Valve Con‐
Flap For Adapta‐ tected DCY trol Unit -
Intake Air tion Val‐ J808- . Re‐
Soiled ue Moni‐ fer to
toring ⇒ “3.6.13
(Top Lim‐ Control
it / Bottom Valve Con‐
Limit) trol Unit
J808 ,
Checking”,
page 920 .
P10A8 Super‐ • Sensor volt‐ • General condi‐ • 0.01 s • 2 DCY – Check the
Adaptation charger age @ low‐ tions: Control
Regulating Bypass er mechani‐ • Once / Valve Con‐
Flap For Adapta‐ cal stop < • Vehicle speed 0 DCY trol Unit -
Intake Air tion Val‐ 0.35 v mph J808- . Re‐
Lower ue Moni‐ • Engine speed fer to
Limit Not toring • Or ⇒ “3.6.13
<= 64 RPM
Reached (Top Lim‐ • Sensor volt‐ Control
it / Bottom age @ low‐ • ECT @ cylinder Valve Con‐
Limit) er mechani‐ block 6 – 105° C trol Unit
cal stop > J808 ,
• IAT @ manifold Checking”,
0.65 v >= 6° C page 920 .
• Or • Time after igni‐
• Diff. sensor tion on > 2.6 s
voltage vs. • Depending on
sensor volt‐ stored limp
age @ low‐ home position:
er mechani‐
cal stop > • Stored sensor
0.40 v voltage @ lower
mechanical stop
• Or < 0.35 V
• Duty cycle • Or
(PWM) <=
0.0 % • Stored sensor
voltage @ lower
mechanical stop
> 0.65 V
• Or
• Limp home posi‐
tion change de‐
tected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P1197 Oxygen • O2S ceram‐ • Heater com‐ • 20.0 s • 2 DCY – Check the
O2 Sensor Sensors ic tempera‐ manded off Oxygen
Heater Cir‐ Heater ture < 680° • Continu‐ Sensor 2
cuit Bank 2 Front 2 C • For time >= 17.0 ous Before Cat‐
Sensor 1 Function‐ s alytic Con‐
al Check • And verter -
GX11- . Re‐
• O2S ceramic fer to
temperature < ⇒ “3.6.41
680° C Oxygen
Sensor 2
• Or Before Cat‐
alytic Con‐
• Case 1: verter
• Integrated sub‐ GX11 ,
mitted heat en‐ Checking”,
ergy >= 1,000.0 page 978 .
J
• Case 2:
• Engine stop time
signal n.a.
• Engine n.a.
• For time >= n.a.
min
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P12A1 Fuel Sys‐ • Phase 1 • Phase 1 DFI- • 5.0 s • 2 DCY – Check the
Fuel Rail tem Pres‐ DFI-mode mode (high pressure in
Pressure sure Sen‐ (high pres‐ pressure-part): • Continu‐ the fuel sys‐
Sensor In‐ sor, High sure-part): ous tem for out
appropri‐ Pressure • Engine speed of spec con‐
ately Low Side Ra‐ • Deviation 576 – 3,008 ditions be‐
tionality lambda of RPM fore diag‐
Check controller nosing the
included • Mass fuel flow
Low set point 15.01 – pressure
adaption < sensor. Re‐
-23.0 % 29.99 mg/rev
fer to Fuel
• High pres‐ • Time after en‐ System Me‐
sure con‐ gine start > 25.0 chanical
troller out‐ s Testing in
put > 30 mg • ⇒ “3.1 Pre‐
Fuel pump deliv‐ liminary
• And ery range < Check”,
54.41 – 290.98 page 20 .
• Phase 2 mg/rev
(MPI-cross – Check the
check): • Engine warm-up Fuel Pres‐
not active sure Sensor
• Lambda
• Catalyst heating - G247- .
controller
n.a. Refer to
included ⇒ “3.6.27
adaption < • Full load n.a. Fuel Pres‐
n.a. % sure Sensor
• Lambda control G247 ,
• For time <= n.a.
n.a. s Checking”,
• Component pro‐ page 948 .
tection n.a.
• Catalyst purge
not active
• Lambda control
n.a.
• Evap purge
functionality di‐
agnosis n.a.
• And
• Depending on
DFI-mode (high
pressure):
• DFI high pres‐
sure part >=
0.80 [-]
• For time >= 20.0
s
• And
• Depending on
mass fuel flow:
• Mass fuel flow >
0.0 mg/rev
• For time >= 2.0 s
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
low dynamic
conditions:
• Diff. mass fuel
flow vs. filtered
mass fuel flow
<= 2.50 mg/rev
• (For mass fuel
flow dynamic
detection)
• For time >= 3.0 s
• And
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Or
• Evap purge n.a.
• And
• Depending on
fuel pump:
• Fuel pump at
max limit
• Or
• Fuel pump com‐
manded on
• And
• Phase 2 (MPI-
cross check):
• Engine speed >
n.a.; < n.a. RPM
• Mass fuel flow
set point (for the
low pressure
part) n.a. mg/rev
• For time >= n.a.
s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P12A2 Fuel Sys‐ • Phase 1 • Phase 1 DFI- • 5.0 s • 2 DCY – Check the
Fuel Rail tem Pres‐ DFI-mode mode (high pressure in
Pressure sure Sen‐ (high pres‐ pressure-part): • Continu‐ the fuel sys‐
Sensor In‐ sor, High sure-part): ous tem for out
appropri‐ Pressure • Engine speed of spec con‐
ately High Side Ra‐ • Deviation 576 – 3,008 ditions be‐
tionality lambda of RPM fore diag‐
Check controller nosing the
included • Mass fuel flow
High set point 34.99 – pressure
adaption > sensor. Re‐
27.50 % 60.0 mg/rev
fer to Fuel
• High pres‐ • Time after en‐ System Me‐
sure con‐ gine start > 25.0 chanical
troller out‐ s Testing in
put < -28 ⇒ “3.1 Pre‐
• Fuel pump deliv‐ liminary
mg ery range < Check”,
• And 54.41 – 290.98 page 20 .
mg/rev
• Phase 2 – Check the
(MPI-cross • Engine warm-up Fuel Pres‐
check): not active sure Sensor
• Catalyst heating - G247- .
• Lambda
n.a. Refer to
controller ⇒ “3.6.27
included • Full load n.a. Fuel Pres‐
adaption < sure Sensor
n.a. % • Lambda control G247 ,
n.a. Checking”,
• For time >=
n.a. s • Component pro‐ page 948 .
tection n.a.
• Catalyst purge
not active
• Lambda control
n.a.
• Evap purge
functionality di‐
agnosis n.a.
• And
• Depending on
DFI-mode (high
pressure):
• DFI high pres‐
sure part >=
0.80 [-]
• For time >= 20.0
s
• And
• Depending on
mass fuel flow:
• Mass fuel flow >
0.0 mg/rev
• For time >= 2.0 s
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Depending on
low dynamic
conditions:
• Diff. mass fuel
flow vs. filtered
mass fuel flow
<= 2.50 mg/rev
• (For mass fuel
flow dynamic
detection)
• For time >= 3.0 s
• And
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Or
• Evap purge n.a.
• And
• Depending on
fuel pump:
• Fuel pump at
max limit
• Or
• Fuel pump com‐
manded on
• And
• Phase 2 (MPI-
cross check):
• Engine speed >
n.a.; < n.a. RPM
• Mass fuel flow
set point (for the
low pressure
part) n.a. mg/rev
• For time >= n.a.
s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P12A4 Fuel Sys‐ • Deviation • Engine speed • 5.0 s • 2 DCY – Check the
Fuel Rail tem Pres‐ between 512 – 8,160 Fuel Pres‐
Pump sure Sen‐ fuel pres‐ RPM • Continu‐ sure Sensor
Control sor, High sure set ous - G247- .
Valve Pressure point and • Mass fuel flow Refer to
Stuck Side Out current fuel set point 5.0 – ⇒ “3.6.27
Closed Of Range pressure < 1,389.0 mg/rev Fuel Pres‐
High -2,999.90 • For time after re‐ sure Sensor
kPa quest for mass G247 ,
fuel flow set Checking”,
• Fuel mass page 948 .
controller point >= 2.0 s
output • Engine start not
-12.50 – active
12.50 %
• Time after en‐
• Case: 1 gine start > 25.0
• High pres‐ s
sure con‐ • Engine warm-up
troller out‐ not active
put < -48
mg • Catalyst heating
n.a.
• Case: 2
• Full load n.a.
• Flow control
valve open • Component pro‐
tection n.a.
• Mass fuel
flow set • Catalyst purge
point > 6.51 not active
mg/rev
• Lambda control
n.a.
• Evap purge
functionality di‐
agnosis not ac‐
tive
• And
• Choice of:
• Canister load <=
0.50 [-]
• Or
• Evap purge
valve not active
or closed
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P13EA Ignition • Ratio be‐ • Engine part load • 0.1 s • 2 DCY – Check the
Cold Start Control tween igni‐ Ignition Coil
Ignition Ignition tion angle • Time @ part • Once / with Power
Timing Timing efficiency load > 5.0 s DCY Output
Perform‐ Monitor integral and • Ignition angle Stage -
ance Off time at part set point <= 0.77 N70- . Refer
Idle load > 0.20 [-] to
– 0.30 [-] ⇒ “3.6.29
• Vehicle speed > Ignition
3 mph Coils With
Power Out‐
• And put Stage ,
Checking”,
• Diff. air mass set page 952 .
point vs. filtered
air mass set
point for load dy‐
namic detection
< 1,389.0 mg/
rev
• For time >= 0.4 s
• and
• Diff. engine
speed vs. fil‐
tered engine
speed for engine
speed dynamic
detection < 200
RPM
• For time >= 0.6 s
P1545 Throttle • Control duty • Throttle position • 5.0 s • 2 DCY – Check the
Throttle Actuator cycle > 98.0 not at min. value Throttle
Actuator Out Of % • Continu‐ Valve Con‐
"A" Control Range • Throttle adapta‐ ous trol Module
Motor Cir‐ tion not active - GX3- . Re‐
cuit • Throttle actuator fer to
Range/ commanded on ⇒ “3.6.45
Perform‐ Throttle
ance Valve Con‐
Throttle • Difference • Throttle adapta‐ • 0.5 s • 2 DCY trol Module
Actuator between tion not active GX3 ,
Rationali‐ throttle po‐ • Continu‐
• Throttle actuator ous Checking”,
ty Check sition set page 987 .
point and commanded on
throttle flap difference be‐
opening an‐ tween throttle
gle for elec‐ position set
tronic throt‐ point and throttle
tle control > flap opening an‐
2.998 – gle <= 1.999; >
24.982° -1.999° TPS
TPS
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P169A ECM: • Transport • Vehicle speed < • 0.01 s • 1 DCY • Refer to ap‐
Loading Transport mode active 3 mph propriate
Mode Ac‐ Mode • Continu‐ repair man‐
tive Function • Max trip mileage ous ual for diag‐
Monitor‐ since initial vehi‐ nosis and
ing: Mode cle start-up < repair.
Change 62.15 [miles
• During ECM
keep alive-time
after ignition off
• Engine speed 0
RPM
• Production
mode not active
• For hybrid:
• Drive motor off
P2004 Intake • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the
Intake Manifold age > 1.76 v ded off Intake
Manifold Runner • Continu‐ Manifold
Runner Flap Ac‐ • For time >= • Time after en‐ ous Runner
Control tuator 4.0 s gine start > 15.0 Control
Stuck Stuck s Valve -
Open Open N316- . Re‐
Bank 1 fer to
⇒ “3.6.31
Intake
Manifold
Runner
Control
Valve
N316 ,
Checking”,
page 956 .
P2005 Intake • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the
Intake Manifold age > 1.76 v ded off Intake
Manifold Runner • Continu‐ Manifold
Runner Flap Ac‐ • For time >= • Time after en‐ ous Runner
Control tuator 2 4.0 s gine start > 15.0 Control
Stuck Stuck s Valve -
Open Open N316- . Re‐
Bank 2 fer to
⇒ “3.6.31
Intake
Manifold
Runner
Control
Valve
N316 ,
Checking”,
page 956 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2006 Intake • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the
Intake Manifold age < 2.71 ded on Intake
Manifold Runner V • Continu‐ Manifold
Runner Flap Ac‐ • Time after en‐ ous Runner
Control tuator • For time >= gine start > 15.0 Control
Stuck Stuck 4.0 s s Valve -
Closed Close N316- . Re‐
Bank 1 fer to
⇒ “3.6.31
Intake
Manifold
Runner
Control
Valve
N316 ,
Checking”,
page 956 .
P2007 Intake • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the
Intake Manifold age < 2.71 ded on Intake
Manifold Runner V • Continu‐ Manifold
Runner Flap Ac‐ • Time after en‐ ous Runner
Control tuator 2 • For time >= gine start > 15.0 Control
Stuck Stuck 4.0 s s Valve -
Closed Close N316- . Re‐
Bank 2 fer to
⇒ “3.6.31
Intake
Manifold
Runner
Control
Valve
N316 ,
Checking”,
page 956 .
P2008 Intake • Output volt‐ • Engine running • 2.0 s • 2 DCY – Check the
Intake Manifold age, lower Intake
Manifold Runner range >= • Actuator com‐ • Continu‐ Manifold
Runner Flap Ac‐ 1.92 – 2.21 manded off ous Runner
Control tuator V Control
Circuit/ Open Cir‐ Valve -
Open cuit • Output volt‐ N316- . Re‐
Bank 1 age, upper fer to
range ⇒ “3.6.31
(hardware Intake
values) <= Manifold
2.85 – 3.25 Runner
V Control
Valve
N316 ,
Checking”,
page 956 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2009 Intake • Output volt‐ • Engine running • 2.0 s • 2 DCY – Check the
Intake Manifold age (hard‐ Intake
Manifold Runner ware val‐ • Actuator com‐ • Continu‐ Manifold
Runner Flap Ac‐ ues) < 1.92 manded off ous Runner
Control tuator – 2.21 V Control
Circuit Short To Valve -
Low Bank Ground • Output volt‐ N316- . Re‐
1 age, upper fer to
range <= ⇒ “3.6.31
2.85 – 3.25 Intake
V Manifold
Runner
Control
Valve
N316 ,
Checking”,
page 956 .
P2010 Intake • Power • Engine running • 2.0 s • 2 DCY – Check the
Intake Manifold stage tem‐ Intake
Manifold Runner perature > • Actuator com‐ • Continu‐ Manifold
Runner Flap Ac‐ 160 – 200° manded on ous Runner
Control tuator C Control
Circuit Short To Valve -
High Bank Battery • Or N316- . Re‐
1 Plus • Output cur‐ fer to
rent (hard‐ ⇒ “3.6.31
ware val‐ Intake
ues) > 1.0 – Manifold
2.0 A Runner
Control
Valve
N316 ,
Checking”,
page 956 .
P2014 Intake • Intake • Engine start not • 0.04 s • 2 DCY – Check the
Intake Manifold manifold active Intake
Manifold Runner runner flap • Continu‐ Manifold
Runner Flap Po‐ position ous Runner Po‐
Position sition sensor volt‐ sition Sen‐
Sensor/ Sensor age < 0.20 sor - G336- .
Switch Cir‐ Short To V Refer to
cuit Bank 1 Ground / ⇒ “3.6.32
Open Cir‐ Intake
cuit Manifold
Runner Po‐
sition Sen‐
sor G336 ,
Checking”,
page 958 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2015 Intake • Diff. actual • Modeled pres‐ • 0.04 s • 2 DCY – Check the
Intake Manifold value vs. sure quotient < Intake
Manifold Runner substitution 0.55 [-] • Once Manifold
Runner Flap Ac‐ value @ per life‐ Runner Po‐
Position tuator lower me‐ • Engine running time sition Sen‐
Sensor/ Adapta‐ chanical • Engine speed > sor - G336- .
Switch Cir‐ tion Val‐ thresh hold 512; < 992 RPM Refer to
cuit ue Moni‐ > 0.86 V ⇒ “3.6.32
Range/ toring • Ect @ cylinder Intake
Perform‐ • Or block > 6° C Manifold
ance Bank • Diff. actual • Runner Po‐
1 Intake manifold sition Sen‐
value vs. runner flap
substitution sor G336 ,
adaptation not Checking”,
value @ up‐ finished
per me‐ page 958 .
chanical
thresh hold
> 0.86 V
• Failed
adaptations
>= 1.00 [-]
P2017 Intake • Intake • Engine start not • 0.04 s • 2 DCY – Check the
Intake Manifold manifold active Intake
Manifold Runner runner flap • Continu‐ Manifold
Runner Flap Po‐ position ous Runner Po‐
Position sition sensor volt‐ sition Sen‐
Sensor/ Sensor age > 4.80 sor - G336- .
Switch Cir‐ Short To V Refer to
cuit High Battery ⇒ “3.6.32
Bank 1 Plus Intake
Manifold
Runner Po‐
sition Sen‐
sor G336 ,
Checking”,
page 958 .
P2019 Intake • Intake • Engine start not • 0.04 s • 2 DCY – Check the
Intake Manifold manifold active Intake
Manifold Runner runner flap • Continu‐ Manifold
Runner Flap Po‐ position ous Runner Po‐
Position sition sensor volt‐ sition Sen‐
Sensor/ Sensor age < 0.20 sor 2 -
Switch Cir‐ Bank 2 V G512- . Re‐
cuit Bank 2 Short To fer to
Ground / ⇒ “3.6.33
Open Cir‐ Intake
cuit Manifold
Runner Po‐
sition Sen‐
sor 2 G512 ,
Checking”,
page 960 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2020 Intake • Diff. actual • Modeled pres‐ • 0.04 s • 2 DCY – Check the
Intake Manifold value vs. sure quotient < Intake
Manifold Runner substitution 0.55 [-] • Once Manifold
Runner Flap Ac‐ value @ per life‐ Runner Po‐
Position tuator 2 lower me‐ • Engine running time sition Sen‐
Sensor/ Adapta‐ chanical • Engine speed > sor 2 -
Switch Cir‐ tion Val‐ thresh hold 512; < 992 RPM G512- . Re‐
cuit ue Moni‐ > 0.86 V fer to
Range/ toring • ECT @ cylinder ⇒ “3.6.33
Perform‐ • Or block > 6° C Intake
ance Bank • Diff. actual • Manifold
2 Intake manifold Runner Po‐
value vs. runner flap
substitution sition Sen‐
adaptation not sor 2 G512 ,
value @ up‐ finished
per me‐ Checking”,
chanical page 960 .
thresh hold
> 0.86 V
• Failed
adaptations
>= 1.00 [-]
P2022 Intake • Intake • Engine start not • 0.04 s • 2 DCY – Check the
Intake Manifold manifold active Intake
Manifold Runner runner flap • Continu‐ Manifold
Runner Flap Po‐ position ous Runner Po‐
Position sition sensor volt‐ sition Sen‐
Sensor/ Sensor age > 4.80 sor 2 -
Switch Cir‐ Bank 2 V G512- . Re‐
cuit High Short To fer to
Bank 2 Battery ⇒ “3.6.33
Plus Intake
Manifold
Runner Po‐
sition Sen‐
sor 2 G512 ,
Checking”,
page 960 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2024 Smart • NVLD out‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Fuel Tempera‐ put voltage EVAP Can‐
Vapor ture Sen‐ lower range • Ignition on • Continu‐ ister Purge
Tempera‐ sor Open >= 1.92 – ous Regulator
• Case 2:
ture Sen‐ Circuit 2.21 V Valve 1 -
sor Circuit • Ignition off (dur‐ N80- . Refer
• NVLD out‐ ing ECM keep to
put voltage alive-time) ⇒ “3.6.20
upper range EVAP Can‐
<= 2.85 – ister Purge
3.25 V Regulator
Valve 1
N80 ,
Checking”,
page 934 .
– Check the
EVAP Sys‐
tem for
Leaks. Re‐
fer to
⇒
“2.2.4 EVA
P System,
Checking
for Leaks”,
page 11 .
P2025 Smart • Diff. time • Ignition off • 3.0 s • 2 DCY – Check the
EVAP Fuel Tempera‐ between EVAP Can‐
Vapor ture Sen‐ ECU and • ECM keep alive • Once / ister Purge
Tempera‐ sor Func‐ smart mod‐ time active DCY Regulator
ture Sen‐ tional ule > 3.0 s Valve 1 -
sor Per‐ Check N80- . Refer
formance • Reset coun‐ • Engine running • 0.1 s to
ter > 3.00 [-] ⇒ “3.6.20
• Last ECM keep • Once / EVAP Can‐
alive mode fin‐ DCY ister Purge
ished Regulator
Valve 1
Smart • Smart mod‐ • Ignition off • 300.0 s N80 ,
Tempera‐ ule temper‐ Checking”,
ture Sen‐ ature > 119° • Fuel level < • Continu‐ page 934 .
sor Out C 85.10 % ous
Of Range • NVLD (EVAP- – Check the
High System) diag‐ EVAP Sys‐
nostic mode ac‐ tem for
tive Leaks. Re‐
fer to
⇒
• Engine running • 30.0 s “2.2.4 EVA
• Continu‐ P System,
ous Checking
for Leaks”,
page 11 .
Smart • Gradient • Ignition off • 300.0 s
Tempera‐ smart tem‐
ture Sen‐ perature > • Fuel level < • Continu‐
sor Sig‐ 20 K / 10 85.10 % ous
nal Dy‐ min • NVLD (EVAP-
namic System) diag‐
Check nostic mode ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Smart • Smart mod‐ • Engine off time • 1.0 s
Tempera‐ ule temper‐ >= 360.0 min
ture Sen‐ ature < -39° • Once /
sor Out C • ECT @ cylinder DCY
Of Range block > -14° C
Low • IAT cross check
finished
• ECT cross
check finished
• ECT @ cylinder
block < 71° C
• Diff. ECT @ cyl‐
inder block @
engine stop @
last driving cycle
vs. actual ECT
@ cylinder block
>= 0° C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2026 Smart • NVLD out‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Fuel Tempera‐ put voltage EVAP Can‐
Vapor ture Sen‐ < 1.92 – • Ignition on • Continu‐ ister Purge
Tempera‐ sor Short 2.21 V ous Regulator
• Case 2:
ture Sen‐ To Valve 1 -
sor Circuit Ground • Ignition off (dur‐ N80- . Refer
Low Volt‐ ing ECM keep to
age alive-time) ⇒ “3.6.20
EVAP Can‐
ister Purge
Regulator
Valve 1
N80 ,
Checking”,
page 934 .
– Check the
EVAP Sys‐
tem for
Leaks. Re‐
fer to
⇒
“2.2.4 EVA
P System,
Checking
for Leaks”,
page 11 .
P2027 Smart • NVLD out‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Fuel Tempera‐ put temper‐ EVAP Can‐
Vapor ture Sen‐ ature > • Ignition on • Continu‐ ister Purge
Tempera‐ sor Short 160.0 – ous Regulator
• Case 2:
ture Sen‐ To Bat‐ 200.0° C Valve 1 -
sor Circuit tery Plus • Ignition off (dur‐ N80- . Refer
High Volt‐ • Or ing ECM keep to
age • NVLD out‐ alive-time) ⇒ “3.6.20
put current EVAP Can‐
4.0 – 7.0 A ister Purge
Regulator
Valve 1
N80 ,
Checking”,
page 934 .
– Check the
EVAP Sys‐
tem for
Leaks. Re‐
fer to
⇒
“2.2.4 EVA
P System,
Checking
for Leaks”,
page 11 .
P2067 CAN: • Instrument • 0.5 s • 2 DCY – Refer to ap‐
Fuel Level Fuel Lev‐ cluster propriate
Sensor "B" el Sensor module sig‐ • Continu‐ wiring dia‐
Circuit 2 CAN nal: short to ous gram. If fuel
Low Commu‐ ground fail‐ level sensor
nication ure and circuitry
With In‐ are ok, then
strument replace the
Cluster instrument
Module cluster. Re‐
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Instrument fer to appro‐
cluster priate repair
module sig‐ manual.
nal: signal
range
check fail‐
ure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2091 VVT Ac‐ • Power • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator stage tem‐ tor solenoid Exhaust
shaft Posi‐ Outlet perature > valve comman‐ • Continu‐ Camshaft
tion Actua‐ Short To 160 – 200° ded on ous Adjustment
tor Control Battery C Valve 1 -
Circuit Plus N318- . Re‐
High Bank • Or fer to
1 • Output cur‐ ⇒ “3.6.21
rent (hard‐ Exhaust
ware val‐ Camshaft
ues) > 4.0 – Adjustment
7.0 A Valve 1
N318 ,
Checking”,
page 936 .
P2092 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"A" Cam‐ tuator In‐ age (hard‐ tor solenoid Camshaft
shaft Posi‐ take ware val‐ valve comman‐ • Continu‐ Adjustment
tion Actua‐ Bank 2 ues) < 1.92 ded off ous Valve 2 -
tor Control Short To – 2.21 V N208- . Re‐
Circuit Ground fer to
Low Bank ⇒ “3.6.3
2 Camshaft
Adjustment
Valve 2
N208 ,
Checking”,
page 899 .
P2093 VVT Ac‐ • Power • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"A" Cam‐ tuator In‐ stage tem‐ tor solenoid Camshaft
shaft Posi‐ take perature > valve comman‐ • Continu‐ Adjustment
tion Actua‐ Bank 2 160 – 200° ded on ous Valve 2 -
tor Control Short To C N208- . Re‐
Circuit Battery fer to
High Bank Plus • Or ⇒ “3.6.3
2 • Output cur‐ Camshaft
rent (hard‐ Adjustment
ware val‐ Valve 2
ues) > 4.0 – N208 ,
7.0 A Checking”,
page 899 .
P2094 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator age (hard‐ tor solenoid Exhaust
shaft Posi‐ Outlet ware val‐ valve comman‐ • Continu‐ Camshaft
tion Actua‐ Bank 2 ues) < 1.92 ded off ous Adjustment
tor Control Short To – 2.21 V Valve 2 -
Circuit Ground N319- . Re‐
Low Bank fer to
2 ⇒ “3.6.22
Exhaust
Camshaft
Adjustment
Valve 2
N319 ,
Checking”,
page 938 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2095 VVT Ac‐ • Power • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator stage tem‐ tor solenoid Exhaust
shaft Posi‐ Outlet perature > valve comman‐ • Continu‐ Camshaft
tion Actua‐ Bank 2 160 – 200° ded on ous Adjustment
tor Control Short To C Valve 2 -
Circuit Battery N319- . Re‐
High Bank Plus • Or fer to
2 • Output cur‐ ⇒ “3.6.22
rent (hard‐ Exhaust
ware val‐ Camshaft
ues) > 4.0 – Adjustment
7.0 A Valve 2
N319 ,
Checking”,
page 938 .
P2096 Fuel Sys‐ • Adaption • 2nd lambda con‐ • 45.0 s • 2 DCY – Check the
Post Cata‐ tem Out value < trol n.a. Oxygen
lyst Fuel Of Range -0.10 [-] • Continu‐ Sensor 1
Trim Sys‐ Low • Catalyst purge ous Before Cat‐
tem Too not active alytic Con‐
Lean Bank • Injection mode verter -
1 change (DFI/ GX10- . Re‐
MFI) not active fer to
⇒ “3.6.39
• Engine speed Oxygen
>= 608 RPM Sensor 1
Before Cat‐
• Counter of inte‐ alytic Con‐
grated mass for verter
fuel in oil < 255.0 GX10 ,
[-] Checking”,
page 972 .
• Choice of:
• O2S rear (bina‐ – Check the
ry) check not ac‐ Oxygen
tive Sensor 1
After Cata‐
• Or lytic Con‐
verter -
• O2S rear (bina‐ GX7- . Re‐
ry) check finish‐ fer to
ed ⇒ “3.6.38
Oxygen
Sensor 1
After Cata‐
lytic Con‐
verter GX7 ,
Checking”,
page 970 .
– Check the
Three Way
Catalytic
Converter
(TWC). Re‐
fer to
⇒ “3.6.44
Three Way
Catalytic
Converter
(TWC),
Checking”,
page 986 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2097 Fuel Sys‐ • Adaption • 2nd lambda con‐ • 45.0 s • 2 DCY – Check the
Post Cata‐ tem Out value > 0.10 trol n.a. Oxygen
lyst Fuel Of Range [-] • Continu‐ Sensor 1
Trim Sys‐ High • Catalyst purge ous Before Cat‐
tem Too not active alytic Con‐
Rich Bank • Injection mode verter -
1 change (DFI/ GX10- . Re‐
MFI) not active fer to
⇒ “3.6.39
• Engine speed Oxygen
>= 608 RPM Sensor 1
Before Cat‐
• Counter of inte‐ alytic Con‐
grated mass for verter
fuel in oil < 255.0 GX10 ,
[-] Checking”,
page 972 .
• Choice of:
• O2S rear (bina‐ – Check the
ry) check not ac‐ Oxygen
tive Sensor 1
After Cata‐
• Or lytic Con‐
verter -
• O2S rear (bina‐ GX7- . Re‐
ry) check finish‐ fer to
ed ⇒ “3.6.38
Oxygen
Sensor 1
After Cata‐
lytic Con‐
verter GX7 ,
Checking”,
page 970 .
– Check the
Three Way
Catalytic
Converter
(TWC). Re‐
fer to
⇒ “3.6.44
Three Way
Catalytic
Converter
(TWC),
Checking”,
page 986 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2098 Fuel Sys‐ • Adaption • 2nd lambda con‐ • 45.0 s • 2 DCY – Check the
Post Cata‐ tem Out value < trol n.a. Oxygen
lyst Fuel Of Range -0.10 [-] • Continu‐ Sensor 2
Trim Sys‐ Low • Catalyst purge ous Before Cat‐
tem Too not active alytic Con‐
Lean Bank • Injection mode verter -
2 change (DFI/ GX11- . Re‐
MFI) not active fer to
⇒ “3.6.41
• Engine speed Oxygen
>= 608 RPM Sensor 2
Before Cat‐
• Counter of inte‐ alytic Con‐
grated mass for verter
fuel in oil < 255.0 GX11 ,
[-] Checking”,
page 978 .
• Choice of:
• O2S rear (bina‐ – Check the
ry) check not ac‐ Oxygen
tive Sensor 2
After Cata‐
• Or lytic Con‐
verter -
• O2S rear (bina‐ GX8- . Re‐
ry) check finish‐ fer to
ed ⇒ “3.6.40
Oxygen
Sensor 2
After Cata‐
lytic Con‐
verter GX8 ,
Checking”,
page 976 .
– Check the
Three Way
Catalytic
Converter
(TWC). Re‐
fer to
⇒ “3.6.44
Three Way
Catalytic
Converter
(TWC),
Checking”,
page 986 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2099 Fuel Sys‐ • Adaption • 2nd lambda con‐ • 45.0 s • 2 DCY – Check the
Post Cata‐ tem Out value > 0.10 trol n.a. Oxygen
lyst Fuel Of Range [-] • Continu‐ Sensor 2
Trim Sys‐ High • Catalyst purge ous Before Cat‐
tem Too not active alytic Con‐
Rich Bank • Injection mode verter -
2 change (DFI/ GX11- . Re‐
MFI) not active fer to
⇒ “3.6.41
• Engine speed Oxygen
>= 608 RPM Sensor 2
Before Cat‐
• Counter of inte‐ alytic Con‐
grated mass for verter
fuel in oil < 255.0 GX11 ,
[-] Checking”,
page 978 .
• Choice of:
• O2S rear (bina‐ – Check the
ry) check not ac‐ Oxygen
tive Sensor 2
After Cata‐
• Or lytic Con‐
verter -
• O2S rear (bina‐ GX8- . Re‐
ry) check finish‐ fer to
ed ⇒ “3.6.40
Oxygen
Sensor 2
After Cata‐
lytic Con‐
verter GX8 ,
Checking”,
page 976 .
– Check the
Three Way
Catalytic
Converter
(TWC). Re‐
fer to
⇒ “3.6.44
Three Way
Catalytic
Converter
(TWC),
Checking”,
page 986 .
P2100 Throttle • Electronic • Difference be‐ • 0.1 s • 2 DCY – Check the
Throttle Actuator throttle tween meas‐ Throttle
Actuator Open Cir‐ valve driver ured and filtered • Continu‐ Valve Con‐
"A" Control cuit load resist‐ throttle position ous trol Module
Motor Cir‐ ance > <= 0.073° TPS - GX3- . Re‐
cuit/Open 200.0 kΩ fer to
• Actuator com‐ ⇒ “3.6.45
manded off Throttle
Valve Con‐
trol Module
GX3 ,
Checking”,
page 987 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2101 Throttle • Electronic • Actuator com‐ • 0.1 s • 2 DCY – Check the
Throttle Actuator throttle manded on Throttle
Actuator Over valve driver • Continu‐ Valve Con‐
"A" Control Tempera‐ tempera‐ ous trol Module
Motor Cir‐ ture ture (hard‐ - GX3- . Re‐
cuit ware val‐ fer to
Range/ ues) > ⇒ “3.6.45
Perform‐ 170.0 – Throttle
ance 190.0° C Valve Con‐
trol Module
GX3 ,
Checking”,
page 987 .
P2103 Throttle • Electronic • Actuator com‐ • 0.1 s • 2 DCY – Check the
Throttle Actuator throttle manded on Throttle
Actuator Short Cir‐ valve driver • Continu‐ Valve Con‐
"A" Control cuit current ous trol Module
Motor Cir‐ (hardware - GX3- . Re‐
cuit High values) > fer to
9.3 – 15.0 A ⇒ “3.6.45
Throttle
Valve Con‐
trol Module
GX3 ,
Checking”,
page 987 .
P2122 Accelera‐ • Signal volt‐ • 0.3 s • 2 DCY – Check the
Throttle/ tor Pedal age sensor Accelerator
Pedal Po‐ Position 1 < 0.40 V • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 1 ous ule - GX2- .
sor/Switch Out Of Refer to
"D" Circuit Range ⇒ “3.6.1 Ac‐
Low Low celerator
Pedal Mod‐
ule GX2 ,
Checking”,
page 895 .
P2123 Accelera‐ • Signal volt‐ • 0.3 s • 2 DCY – Check the
Throttle/ tor Pedal age sensor Accelerator
Pedal Po‐ Position 1 > 4.82 V • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 1 ous ule - GX2- .
sor/Switch Out Of Refer to
"D" Circuit Range ⇒ “3.6.1 Ac‐
High High celerator
Pedal Mod‐
ule GX2 ,
Checking”,
page 895 .
P2127 Accelera‐ • Signal volt‐ • 0.3 s • 2 DCY – Check the
Throttle/ tor Pedal age sensor Accelerator
Pedal Po‐ Position 2 < 0.20 V • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 2 ous ule - GX2- .
sor/Switch Out Of Refer to
"E" Circuit Range ⇒ “3.6.1 Ac‐
Low Low celerator
Pedal Mod‐
ule GX2 ,
Checking”,
page 895 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2128 Accelera‐ • Signal volt‐ • 0.3 s • 2 DCY – Check the
Throttle/ tor Pedal age sensor Accelerator
Pedal Po‐ Position 2 > 2.80 V • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 2 ous ule - GX2- .
sor/Switch Out Of Refer to
"E" Circuit Range ⇒ “3.6.1 Ac‐
High High celerator
Pedal Mod‐
ule GX2 ,
Checking”,
page 895 .
P2138 Accelera‐ • Difference • 0.4 s • 2 DCY – Check the
Throttle/ tor Pedal between Accelerator
Pedal Po‐ Position signal volt‐ • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 1 age sensor ous ule - GX2- .
sor/Switch and 2 Ra‐ 1 and sen‐ Refer to
"D"/"E" tionality sor 2 > 0.10 ⇒ “3.6.1 Ac‐
Voltage Check – 0.12 V celerator
Correla‐ Pedal Mod‐
tion ule GX2 ,
Checking”,
page 895 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2177 Fuel Sys‐ • Adaptive • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
System tem Too value >= 25 mg/rev Oxygen
Too Lean Lean @ % • Continu‐ Sensor 1
Off Idle Part Load • ECT @ cylinder ous Before Cat‐
Bank 1 block > 70° C alytic Con‐
• IAT @ manifold verter -
> -11° C GX10- . Re‐
fer to
• AAT > -48° C ⇒ “3.6.39
Oxygen
• Lambda set Sensor 1
point 0.92 – 1.05 Before Cat‐
[-] alytic Con‐
verter
• Lambda control GX10 ,
closed loop Checking”,
• Integrated air page 972 .
mass >= 30.0 g
– Check the
• Mass fuel flow Oxygen
13.01 – 36.01 Sensor 1
mg/rev After Cata‐
lytic Con‐
• Engine speed verter -
704 – 4,960 GX7- . Re‐
RPM fer to
• Ethanol value ⇒ “3.6.38
n.a. Oxygen
Sensor 1
• Low dynamic After Cata‐
conditions: lytic Con‐
verter GX7 ,
• Diff. engine Checking”,
speed vs. aver‐ page 970 .
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge flow
at max. value
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2178 Fuel Sys‐ • Adaptive • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
System tem Too value <= mg/rev Oxygen
Too Rich Rich @ -25 % • Continu‐ Sensor 1
Off Idle Part Load • ECT @ cylinder ous Before Cat‐
Bank 1 block > 70° C alytic Con‐
• IAT @ manifold verter -
> -11° C GX10- . Re‐
fer to
• AAT > -48° C ⇒ “3.6.39
Oxygen
• Lambda set Sensor 1
point 0.92 – 1.05 Before Cat‐
[-] alytic Con‐
verter
• Lambda control GX10 ,
closed loop Checking”,
• Integrated air page 972 .
mass >= 30.0 g
– Check the
• Mass fuel flow Oxygen
13.01 – 36.01 Sensor 1
mg/rev After Cata‐
lytic Con‐
• Engine speed verter -
704 – 4,960 GX7- . Re‐
RPM fer to
• Ethanol value ⇒ “3.6.38
n.a. Oxygen
Sensor 1
• Low dynamic After Cata‐
conditions: lytic Con‐
verter GX7 ,
• Diff. engine Checking”,
speed vs. aver‐ page 970 .
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge flow
at max. value
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2179 Fuel Sys‐ • Adaptive • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
System tem Too value >= 25 mg/rev Oxygen
Too Lean Lean @ % • Continu‐ Sensor 2
Off Idle Part Load • ECT @ cylinder ous Before Cat‐
Bank 2 block > 70° C alytic Con‐
• IAT @ manifold verter -
> -11° C GX11- . Re‐
fer to
• AAT > -48° C ⇒ “3.6.41
Oxygen
• Lambda set Sensor 2
point 0.92 – 1.05 Before Cat‐
[-] alytic Con‐
verter
• Lambda control GX11 ,
closed loop Checking”,
• Integrated air page 978 .
mass >= 30.0 g
– Check the
• Mass fuel flow Oxygen
13.01 – 36.01 Sensor 2
mg/rev After Cata‐
lytic Con‐
• Engine speed verter -
704 – 4,960 GX8- . Re‐
RPM fer to
• Ethanol value ⇒ “3.6.40
n.a. Oxygen
Sensor 2
• Low dynamic After Cata‐
conditions: lytic Con‐
verter GX8 ,
• Diff. engine Checking”,
speed vs. aver‐ page 976 .
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge flow
at max. value
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2180 Fuel Sys‐ • Adaptive • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
System tem Too value <= mg/rev Oxygen
Too Rich Rich @ -25 % • Continu‐ Sensor 2
Off Idle Part Load • ECT @ cylinder ous Before Cat‐
Bank 2 block > 70° C alytic Con‐
• IAT @ manifold verter -
> -11° C GX11- . Re‐
fer to
• AAT > -48° C ⇒ “3.6.41
Oxygen
• Lambda set Sensor 2
point 0.92 – 1.05 Before Cat‐
[-] alytic Con‐
verter
• Lambda control GX11 ,
closed loop Checking”,
• Integrated air page 978 .
mass >= 30.0 g
– Check the
• Mass fuel flow Oxygen
13.01 – 36.01 Sensor 2
mg/rev After Cata‐
lytic Con‐
• Engine speed verter -
704 – 4,960 GX8- . Re‐
RPM fer to
• Ethanol value ⇒ “3.6.40
n.a. Oxygen
Sensor 2
• Low dynamic After Cata‐
conditions: lytic Con‐
verter GX8 ,
• Diff. engine Checking”,
speed vs. aver‐ page 976 .
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge flow
at max. value
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2181 Engine • Modeled • ECT @ cylinder • 1.0 s • 2 DCY – Check the
Cooling Cooling ECT @ cyl‐ block @ first Engine
System System inder block start >= -8° C • Once / Coolant
Perform‐ Rationali‐ > 87° C DCY Tempera‐
ance ty Check • ECT @ cylinder ture Sensor
• Choice of: block @ first - G62- . Re‐
start <= -48 – fer to
• ECT @ cyl‐ 57° C
inder block ⇒ “3.6.17
< -48 – 76° • AAT > -8° C Engine
C Coolant
• Ratio accumula‐ Tempera‐
• Or ted time fuel cut ture Sensor
off vs. time since G62 ,
• ECT @ cyl‐ engine start <= Checking”,
inder head 26.95 % page 928 .
< n.a.° C
• Ratio accumula‐ – Check the
ted time engine Coolant Re‐
load condition circulation
vs. time since Pump -
engine start <= V50- . Refer
50.0 % to
⇒ “3.6.14
• Determination Coolant Re‐
engine load con‐ circulation
dition: Pump V50 ,
• Engine load Checking”,
(lower thresh‐ page 922 .
old) <= 2.50 %
– Check the
• Engine load (up‐ engine
per threshold) coolant
>= 40.0 % thermostat.
Refer to ap‐
• Ratio accumula‐ propriate
ted time high repair man‐
speed condition ual.
<= 40.23 %
• Determination
high speed con‐
dition:
• Vehicle speed >
75 mph
• Ratio accumula‐
ted time start-
stop active <=
15.23 %
• Case 1:
• Engine speed <
4,500 RPM
• Case 2:
• Engine speed
>= 4,500 RPM
• Diff. ECT@ cyl‐
inder block dur‐
ing measure‐
ment < 50° C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• For time >= 40.0
s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2187 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
System tem Too mg/rev Oxygen
Too Lean Lean @ • Adaptive • Continu‐ Sensor 1
at Idle Idle value >= • ECT @ cylinder ous Before Cat‐
Bank 1 n.a. mg/rev block > 70° C alytic Con‐
• Case 2: • IAT @ manifold verter -
> -11° C GX10- . Re‐
• Adaptive fer to
value >= • AAT > -48° C ⇒ “3.6.39
0.33 kg/h Oxygen
• Lambda set Sensor 1
point 0.92 – 1.05 Before Cat‐
[-] alytic Con‐
verter
• Lambda control GX10 ,
closed loop Checking”,
• Integrated air page 972 .
mass >= 30.0 g
• Vehicle speed <
31 mph
• Ethanol value
n.a.
• Low dynamic
conditions:
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Mass fuel flow
upper range <
0.0 – 15.01 mg/
rev
• Mass fuel flow
lower range >
5.0 – 9.01 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Engine speed
704 – 1,504
RPM
• Or
• Engine n.a.
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
• Evap purge flow
at max. value
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2188 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
System tem Too mg/rev Oxygen
Too Rich Rich @ • Adaptive • Continu‐ Sensor 1
at Idle Idle value <= • ECT @ cylinder ous Before Cat‐
Bank 1 n.a. mg/rev block > 70° C alytic Con‐
• Case 2: • IAT @ manifold verter -
> -11° C GX10- . Re‐
• Adaptive fer to
value <= • AAT > -48° C ⇒ “3.6.39
-0.33 kg/h Oxygen
• Lambda set Sensor 1
point 0.92 – 1.05 Before Cat‐
[-] alytic Con‐
verter
• Lambda control GX10 ,
closed loop Checking”,
• Integrated air page 972 .
mass >= 30.0 g
• Vehicle speed <
31 mph
• Ethanol value
n.a.
• Low dynamic
conditions:
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Mass fuel flow
lower range >
5.0 – 9.01 mg/
rev
• Mass fuel flow
upper range <
0.0 – 15.01 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Engine speed
704 – 1,504
RPM
• Or
• Engine n.a.
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
• Evap purge flow
at max. value
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2189 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
System tem Too mg/rev Oxygen
Too Lean Lean @ • Adaptive • Continu‐ Sensor 2
at Idle Idle value >= • ECT @ cylinder ous Before Cat‐
Bank 2 n.a. mg/rev block > 70° C alytic Con‐
• Case 2: • IAT @ manifold verter -
> -11° C GX11- . Re‐
• Adaptive fer to
value >= • AAT > -48° C ⇒ “3.6.41
0.33 kg/h Oxygen
• Lambda set Sensor 2
point 0.92 – 1.05 Before Cat‐
[-] alytic Con‐
verter
• Lambda control GX11 ,
closed loop Checking”,
• Integrated air page 978 .
mass >= 30.0 g
• Vehicle speed <
31 mph
• Ethanol value
n.a.
• Low dynamic
conditions:
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Mass fuel flow
upper range <
0.0 – 15.01 mg/
rev
• Mass fuel flow
lower range >
5.0 – 9.01 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Engine speed
704 – 1,504
RPM
• Or
• Engine n.a.
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
• Evap purge flow
at max. value
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2190 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
System tem Too mg/rev Oxygen
Too Rich Rich @ • Adaptive • Continu‐ Sensor 2
at Idle Idle value <= • ECT @ cylinder ous Before Cat‐
Bank 2 n.a. mg/rev block > 70° C alytic Con‐
• Case 2: • IAT @ manifold verter -
> -11° C GX11- . Re‐
• Adaptive fer to
value <= • AAT > -48° C ⇒ “3.6.41
-0.33 kg/h Oxygen
• Lambda set Sensor 2
point 0.92 – 1.05 Before Cat‐
[-] alytic Con‐
verter
• Lambda control GX11 ,
closed loop Checking”,
• Integrated air page 978 .
mass >= 30.0 g
• Vehicle speed <
31 mph
• Ethanol value
n.a.
• Low dynamic
conditions:
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Mass fuel flow
lower range >
5.0 – 9.01 mg/
rev
• Mass fuel flow
upper range <
0.0 – 15.01 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Engine speed
704 – 1,504
RPM
• Or
• Engine n.a.
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
• Evap purge flow
at max. value
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2195 Oxygen • Plausibility • O2S front ready • 270.0 s • 2 DCY – Check the
O2 Sensor Sensors check up‐ Oxygen
Signal Front Ra‐ stream and • O2S rear ready • Continu‐ Sensor 1
Biased/ tionality down‐ ous Before Cat‐
• ECT @ cylinder
Stuck Check stream oxy‐ block >= 60° C alytic Con‐
Lean Bank gen sensor verter -
1 Sensor 1 signal: • MAF > 30.00; < GX10- . Re‐
300.0 kg/h fer to
• Lambda ⇒ “3.6.39
value < 0.85 • Catalyst purge Oxygen
[-] not active Sensor 1
• And Before Cat‐
• Integrated air alytic Con‐
mass after end
• O2S signal verter
of catalyst purge
rear <= 0.15 GX10 ,
>= 0.0 g
V Checking”,
• Engine speed > page 972 .
992 RPM
• EGT @ O2S
front > 300; <
841° C
• Injection mode
change (DFI/
MFI) not active
• Integrated air
mass > 40.0 g
• Dynamic lamb‐
da controller
output < 3.0 %
• Dynamic MAF <
0.10 g/rev
• Dynamic engine
speed < 300
RPM
• And
• Second control
loop active:
• Air mass 0.07 –
0.75 g/rev
• Engine speed
608 – 4,512
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Open loop • Fuel cut off not • 384.0 s
check: active
• Continu‐
• Lambda set • Engine running ous
value 0.80
[-] • And
• And • Choice of:
• O2S signal • Fuel trim diag‐
front > 0.96 nosis failure de‐
[-] tected
• Or
• O2S rear sensor
plausibility fail‐
ure detected
• And
• Choice of:
• Lambda adapta‐
tion value >=
0.13 [-]
• Or
• Lambda adapta‐
tion value <=
-0.13 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2196 Oxygen • Plausibility • O2S front ready • 270.0 s • 2 DCY – Check the
O2 Sensor Sensors check up‐ Oxygen
Signal Front Ra‐ stream and • O2S rear ready • Continu‐ Sensor 1
Biased/ tionality down‐ ous Before Cat‐
• ECT @ cylinder
Stuck Rich Check stream oxy‐ block >= 60° C alytic Con‐
Bank 1 gen sensor verter -
Sensor 1 signal: • MAF > 30.00; < GX10- . Re‐
300.0 kg/h fer to
• Lambda ⇒ “3.6.39
value > 1.24 • Catalyst purge Oxygen
[-] not active Sensor 1
• And Before Cat‐
• Integrated air alytic Con‐
mass after end
• O2S signal verter
of catalyst purge
rear >= 0.82 GX10 ,
>= 0.0 g
V Checking”,
• Engine speed > page 972 .
992 RPM
• EGT @ O2S
front > 300; <
841° C
• Injection mode
change (DFI/
MFI) not active
• Integrated air
mass > 40.0 g
• Dynamic lamb‐
da controller
output < 3.0 %
• Dynamic MAF <
0.10 g/rev
• Dynamic engine
speed < 300
RPM
• And
• Second control
loop active:
• Air mass 0.07 –
0.75 g/rev
• Engine speed
608 – 4,512
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Open loop • Fuel cut off not • 384.0 s
check: active
• Continu‐
• Lambda set • Engine running ous
value 1.15
[-] • And
• And • Choice of:
• O2S signal • Fuel trim diag‐
front < 1.04 nosis failure de‐
[-] tected
• Or
• O2S rear sensor
plausibility fail‐
ure detected
• And
• Choice of:
• Lambda adapta‐
tion value >=
0.13 [-]
• Or
• Lambda adapta‐
tion value <=
-0.13 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2197 Oxygen • Plausibility • O2S front ready • 270.0 s • 2 DCY – Check the
O2 Sensor Sensors check up‐ Oxygen
Signal Front stream and • O2S rear ready • Continu‐ Sensor 2
Biased/ Bank 2 down‐ ous Before Cat‐
• ECT @ cylinder
Stuck Rationali‐ stream oxy‐ block >= 60° C alytic Con‐
Lean Bank ty Check gen sensor verter -
2 Sensor 1 signal: • MAF > 30.00; < GX11- . Re‐
300.0 kg/h fer to
• Lambda ⇒ “3.6.41
value > 1.24 • Catalyst purge Oxygen
[-] not active Sensor 2
• And Before Cat‐
• Integrated air alytic Con‐
mass after end
• O2S signal verter
of catalyst purge
rear >= 0.82 GX11 ,
>= 0.0 g
V Checking”,
• Engine speed > page 978 .
992 RPM
• EGT @ O2S
front > 300; <
841° C
• Injection mode
change (DFI/
MFI) not active
• Integrated air
mass > 40.0 g
• Dynamic lamb‐
da controller
output < 3.0 %
• Dynamic air
mass < 0.10 g/
rev
• Dynamic engine
speed < 300
RPM
• And
• Second control
loop active:
• Air mass 0.07 –
0.75 g/rev
• Engine speed
608 – 4,512
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Open loop • Fuel cut off not • 384.0 s
check: active
• Continu‐
• Lambda set • Engine running ous
value 1.15
[-] • And
• And • Choice of:
• O2S signal • Fuel trim diag‐
front < 1.04 nosis failure de‐
[-] tected
• Or
• O2S rear sensor
plausibility fail‐
ure detected
• And
• Choice of:
• Lambda adapta‐
tion value >=
0.13 [-]
• Or
• Lambda adapta‐
tion value <=
-0.13 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2198 Oxygen • Plausibility • O2S front ready • 270.0 s • 2 DCY – Check the
O2 Sensor Sensors check up‐ Oxygen
Signal Front stream and • O2S rear ready • Continu‐ Sensor 2
Biased/ Bank 2 down‐ ous Before Cat‐
• ECT @ cylinder
Stuck Rich Rationali‐ stream oxy‐ block >= 60° C alytic Con‐
Bank 2 ty Check gen sensor verter -
Sensor 1 signal: • MAF > 30.00; < GX11- . Re‐
300.0 kg/h fer to
• Lambda ⇒ “3.6.41
value < 0.85 • Catalyst purge Oxygen
[-] not active Sensor 2
• And Before Cat‐
• Integrated air alytic Con‐
mass after end
• O2S signal verter
of catalyst purge
rear <= 0.15 GX11 ,
>= 0.0 g
V Checking”,
• Engine speed > page 978 .
992 RPM
• EGT @ O2S
front > 300; <
841° C
• Injection mode
change (DFI/
MFI) not active
• Integrated air
mass > 40.0 g
• Dynamic lamb‐
da controller
output < 3.0 %
• Dynamic air
mass < 0.10 g/
rev
• Dynamic engine
speed < 300
RPM
• And
• Second control
loop active:
• Air mass 0.07 –
0.75 g/rev
• Engine speed
608 – 4,512
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Open loop • Fuel cut off not • 384.0 s
check: active
• Continu‐
• Lambda set • Engine running ous
value 0.80
[-] • And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • ECT @ cylinder
tem Di‐ value of cyl‐ block > 70° C
rect Fuel inder indi‐
Injection vidual lamb‐ • Diff. pump volt‐
A/F Im‐ da control < age (VIP) vs. vir‐
balance: -10.0 % tual ground volt‐
Out Of age (VG) < -2.1;
Range > 2.1 V
Low • O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
• Target fuel
mass, upper
range <= 0.0 –
34.0 mg/rev
• Engine no full
load
• Catalyst heating
not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P219D Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 2 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 2
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
Ratio Im‐ Injection vidual lamb‐ ous tor - N31- .
balance A/F Im‐ da control > • Air mass 0.0 – Refer to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P219E Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 3 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 3
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
Ratio Im‐ Injection vidual lamb‐ ous tor - N32- .
balance A/F Im‐ da control > • Air mass 0.0 – Refer to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P219F Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 4 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 4
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
Ratio Im‐ Injection vidual lamb‐ ous tor - N33- .
balance A/F Im‐ da control > • Air mass 0.0 – Refer to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21A0 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 5 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 5
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
Ratio Im‐ Injection vidual lamb‐ ous tor - N83- .
balance A/F Im‐ da control > • Air mass 0.0 – Refer to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21A1 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 6 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 6
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
Ratio Im‐ Injection vidual lamb‐ ous tor - N84- .
balance A/F Im‐ da control > • Air mass 0.0 – Refer to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21CF Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 1 Valves driver volt‐ active CRK Cylinder 1
Injector Open Cir‐ age, lower Fuel Injec‐
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ tor 2 -
Open – 2.21 V active ous N532- . Re‐
• Engine speed > fer to
• Injector ⇒ “3.6.25
driver volt‐ 0 RPM
Fuel Injec‐
age, upper • No full load tors (2 [B
range Circuit]),
(hardware • Or Checking”,
values) page 944 .
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0 ms
• Actuator com‐
manded off
P21D0 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 2 Valves driver volt‐ active CRK Cylinder 2
Injector Open Cir‐ age, lower Fuel Injec‐
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ tor 2 -
Open – 2.21 V active ous N533- . Re‐
• Engine speed > fer to
• Injector ⇒ “3.6.25
driver volt‐ 0 RPM
Fuel Injec‐
age, upper • No full load tors (2 [B
range Circuit]),
(hardware • Or Checking”,
values) page 944 .
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0 ms
• Actuator com‐
manded off
P21D1 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 3 Valves driver volt‐ active CRK Cylinder 3
Injector Open Cir‐ age, lower Fuel Injec‐
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ tor 2 -
Open – 2.21 V active ous N534- . Re‐
• Engine speed > fer to
• Injector ⇒ “3.6.25
driver volt‐ 0 RPM
Fuel Injec‐
age, upper • No full load tors (2 [B
range Circuit]),
(hardware • Or Checking”,
values) page 944 .
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0 ms
• Actuator com‐
manded off
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21D2 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 4 Valves driver volt‐ active CRK Cylinder 4
Injector Open Cir‐ age, lower Fuel Injec‐
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ tor 2 -
Open – 2.21 V active ous N535- . Re‐
• Engine speed > fer to
• Injector ⇒ “3.6.25
driver volt‐ 0 RPM
Fuel Injec‐
age, upper • No full load tors (2 [B
range Circuit]),
(hardware • Or Checking”,
values) page 944 .
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0.0 ms
• Actuator com‐
manded off
P21D3 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 5 Valves driver volt‐ active CRK Cylinder 5
Injector Open Cir‐ age, lower Fuel Injec‐
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ tor 2 -
Open – 2.21 V active ous N536- . Re‐
• Engine speed > fer to
• Injector ⇒ “3.6.25
driver volt‐ 0 RPM
Fuel Injec‐
age, upper • No full load tors (2 [B
range Circuit]),
(hardware • Or Checking”,
values) page 944 .
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0.0 ms
• Actuator com‐
manded off
P21D4 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 6 Valves driver volt‐ active CRK Cylinder 6
Injector Open Cir‐ age, lower Fuel Injec‐
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ tor 2 -
Open – 2.21 V active ous N537- . Re‐
• Engine speed > fer to
• Injector ⇒ “3.6.25
driver volt‐ 0 RPM
Fuel Injec‐
age, upper • No full load tors (2 [B
range Circuit]),
(hardware • Or Checking”,
values) page 944 .
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0.0 ms
• Actuator com‐
manded off
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21DB Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 1 Valves driver volt‐ active CRK Cylinder 1
Injector Short To age (hard‐ Fuel Injec‐
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ tor 2 -
Low ues) < 1.92 active ous N532- . Re‐
– 2.21 V • Engine speed > fer to
0 RPM ⇒ “3.6.25
Fuel Injec‐
• Injection time > tors (2 [B
0.0 ms Circuit]),
Checking”,
• Actuator com‐ page 944 .
manded off
P21DC Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 1 Valves driver cur‐ active CRK Cylinder 1
Injector Short To rent > 4.0 – Fuel Injec‐
"B" Circuit Battery 7.0 A • Fuel cut off not • Continu‐ tor 2 -
High Plus active ous N532- . Re‐
• Or fer to
• Engine speed >
• Power 0 RPM ⇒ “3.6.25
stage tem‐ Fuel Injec‐
perature • Injection time > tors (2 [B
hardware 0.0 ms Circuit]),
values) > Checking”,
• Actuator com‐ page 944 .
160 – 200° manded on
C
P21DE Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 2 Valves driver volt‐ active CRK Cylinder 2
Injector Short To age (hard‐ Fuel Injec‐
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ tor 2 -
Low ues) < 1.92 active ous N533- . Re‐
– 2.21 V • Engine speed > fer to
0 RPM ⇒ “3.6.25
Fuel Injec‐
• Injection time > tors (2 [B
0.0 ms Circuit]),
Checking”,
• Actuator com‐ page 944 .
manded off
P21DF Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 2 Valves driver cur‐ active CRK Cylinder 2
Injector Short To rent > 4.0 – Fuel Injec‐
"B" Circuit Battery 7.0 A • Fuel cut off not • Continu‐ tor 2 -
High Plus active ous N533- . Re‐
• Or fer to
• Engine speed >
• Power 0 RPM ⇒ “3.6.25
stage tem‐ Fuel Injec‐
perature • Injection time > tors (2 [B
hardware 0.0 ms Circuit]),
values) > Checking”,
• Actuator com‐ page 944 .
160 – 200° manded on
C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21E0 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 3 Valves driver volt‐ active CRK Cylinder 3
Injector Short To age (hard‐ Fuel Injec‐
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ tor 2 -
Low ues) < 1.92 active ous N534- . Re‐
– 2.21 V • Engine speed > fer to
0 RPM ⇒ “3.6.25
Fuel Injec‐
• Injection time > tors (2 [B
0.0 ms Circuit]),
Checking”,
• Actuator com‐ page 944 .
manded off
P21E1 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 3 Valves driver cur‐ active CRK Cylinder 3
Injector Short To rent > 4.0 – Fuel Injec‐
"B" Circuit Battery 7.0 A • Fuel cut off not • Continu‐ tor 2 -
High Plus active ous N534- . Re‐
• Or fer to
• Engine speed >
• Power 0 RPM ⇒ “3.6.25
stage tem‐ Fuel Injec‐
perature • Injection time > tors (2 [B
hardware 0.0 ms Circuit]),
values) > Checking”,
• Actuator com‐ page 944 .
160 – 200° manded on
C
P21E2 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 4 Valves driver volt‐ active CRK Cylinder 4
Injector Short To age (hard‐ Fuel Injec‐
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ tor 2 -
Low ues) < 1.92 active ous N535- . Re‐
– 2.21 V • Engine speed > fer to
0 RPM ⇒ “3.6.25
Fuel Injec‐
• Injection time > tors (2 [B
0.0 ms Circuit]),
Checking”,
• Actuator com‐ page 944 .
manded off
P21E3 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 4 Valves driver cur‐ active CRK Cylinder 4
Injector Short To rent > 4.0 – Fuel Injec‐
"B" Circuit Battery 7.0 A • Fuel cut off not • Continu‐ tor 2 -
High Plus active ous N535- . Re‐
• Or fer to
• Engine speed >
• Power 0 RPM ⇒ “3.6.25
stage tem‐ Fuel Injec‐
perature • Injection time > tors (2 [B
hardware 0.0 ms Circuit]),
values) > Checking”,
• Actuator com‐ page 944 .
160 – 200° manded on
C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21E4 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 5 Valves driver volt‐ active CRK Cylinder 5
Injector Short To age (hard‐ Fuel Injec‐
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ tor 2 -
Low ues) < 1.92 active ous N536- . Re‐
– 2.21 V • Engine speed > fer to
0 RPM ⇒ “3.6.25
Fuel Injec‐
• Injection time > tors (2 [B
0.0 ms Circuit]),
Checking”,
• Actuator com‐ page 944 .
manded off
P21E5 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 5 Valves driver cur‐ active CRK Cylinder 5
Injector Short To rent > 4.0 – Fuel Injec‐
"B" Circuit Battery 7.0 A • Fuel cut off not • Continu‐ tor 2 -
High Plus active ous N536- . Re‐
• Or fer to
• Engine speed >
• Power 0 RPM ⇒ “3.6.25
stage tem‐ Fuel Injec‐
perature • Injection time > tors (2 [B
hardware 0.0 ms Circuit]),
values) > Checking”,
• Actuator com‐ page 944 .
160 – 200° manded on
C
P21E6 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 6 Valves driver volt‐ active CRK Cylinder 6
Injector Short To age (hard‐ Fuel Injec‐
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ tor 2 -
Low ues) < 1.92 active ous N537- . Re‐
– 2.21 V • Engine speed > fer to
0 RPM ⇒ “3.6.25
Fuel Injec‐
• Injection time > tors (2 [B
0.0 ms Circuit]),
Checking”,
• Actuator com‐ page 944 .
manded off
P21E7 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 6 Valves driver cur‐ active CRK Cylinder 6
Injector Short To rent > 4.0 – Fuel Injec‐
"B" Circuit Battery 7.0 A • Fuel cut off not • Continu‐ tor 2 -
High Plus active ous N537- . Re‐
• Or fer to
• Engine speed >
• Power 0 RPM ⇒ “3.6.25
stage tem‐ Fuel Injec‐
perature • Injection time > tors (2 [B
hardware 0.0 ms Circuit]),
values) > Checking”,
• Actuator com‐ page 944 .
160 – 200° manded on
C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21F4 Fuel Sys‐ • Adaption • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ value >= mg/rev Fuel Deliv‐
trol Sys‐ port Fuel 25.0 % • Continu‐ ery Unit -
tem "B" Injection • ECT @ cylinder ous GX1- . Re‐
Too Lean System block > 70° C fer to
Off Idle Too Lean • IAT @ manifold ⇒ “3.6.23
Bank 1 @ Part > -11° C Fuel Deliv‐
Load ery Unit
• AAT > -48° C GX1 ,
Checking”,
• lambda set point page 940 .
0.92 – 1.05 [-]
– Check the
• Lambda control fuel pres‐
closed loop inte‐ sure regula‐
grated air mass tor and re‐
> 30.0 g sidual pres‐
• Fuel mass 13.01 sure. Refer
– 36.01 mg/rev to appropri‐
ate repair
• Engine speed manual.
704 – 4,960
RPM – Check the
Fuel Injec‐
• Ethanol value tors (2 [B
n.a. Circuit]).
• Low dynamic Refer to
conditions: ⇒ “3.6.25
Fuel Injec‐
• Diff. engine tors (2 [B
speed vs. aver‐ Circuit]),
aged engine Checking”,
speed for engine page 944 .
speed dynamic
detection < 150 – Check the
RPM Fuel Pres‐
sure Sensor
• Diff. air mass vs. - G247- .
averaged air Refer to
mass for load ⇒ “3.6.27
dynamic detec‐ Fuel Pres‐
tion < 130.01 sure Sensor
mg/rev G247 ,
• Diff. between Checking”,
reference and page 948 .
actual fuel pres‐
sure, high side – Check in‐
<= 34,777.60 take system
kPa visually for
leaks (false
• Integrated air air).
mass > 15.0 –
70.0 g – Check the
Oxygen
• And Sensor 1
• Evap purge Before Cat‐
valve closed alytic Con‐
verter -
• Or GX10- . Re‐
fer to
• Canister load <= ⇒ “3.6.39
2.0 [-] Oxygen
Sensor 1
Before Cat‐
alytic Con‐
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge verter
valve at max. GX10 ,
value Checking”,
page 972 .
• Or
• Dependence on – Check the
canister purge Oxygen
min: Sensor 1
After Cata‐
• Lower limit of lytic Con‐
lambda control‐ verter -
ler output n.a. GX7- . Re‐
fer to
• Or ⇒ “3.6.38
Oxygen
• Upper limit of Sensor 1
lambda control‐ After Cata‐
ler output n.a. lytic Con‐
• And verter GX7 ,
Checking”,
• Evap purge flow page 970 .
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21F5 Fuel Sys‐ • Adaption • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ value <= mg/rev fuel pres‐
trol Sys‐ port Fuel -25.0 % • Continu‐ sure regula‐
tem "B" Injection • ECT @ cylinder ous tor and re‐
Too Rich System block > 70° C sidual pres‐
Off Idle Too Rich • IAT @ manifold sure. Refer
Bank 1 @ Part > -11° C to appropri‐
Load ate repair
• AAT > -48° C manual.
• lambda set point – Check the
0.92 – 1.05 [-] Fuel Injec‐
tors (2 [B
• Lambda control Circuit]).
closed loop inte‐ Refer to
grated air mass ⇒ “3.6.25
> 30.0 g Fuel Injec‐
• Fuel mass 13.01 tors (2 [B
– 36.01 mg/rev Circuit]),
Checking”,
• Engine speed page 944 .
704 – 4,960
RPM – Check the
Fuel Pres‐
• Ethanol value sure Sensor
n.a. - G247- .
• Low dynamic Refer to
conditions: ⇒ “3.6.27
Fuel Pres‐
• Diff. engine sure Sensor
speed vs. aver‐ G247 ,
aged engine Checking”,
speed for engine page 948 .
speed dynamic
detection < 150 – Check the
RPM Oxygen
Sensor 1
• Diff. air mass vs. Before Cat‐
averaged air alytic Con‐
mass for load verter -
dynamic detec‐ GX10- . Re‐
tion < 130.01 fer to
mg/rev ⇒ “3.6.39
• Diff. between Oxygen
reference and Sensor 1
actual fuel pres‐ Before Cat‐
sure, high side alytic Con‐
<= 34,777.60 verter
kPa GX10 ,
Checking”,
• Integrated air page 972 .
mass > 15.0 –
70.0 g – Check the
Oxygen
• And Sensor 1
• Evap purge After Cata‐
valve closed lytic Con‐
verter -
• Or GX7- . Re‐
fer to
• Canister load <= ⇒ “3.6.38
2.0 [-] Oxygen
Sensor 1
After Cata‐
lytic Con‐
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge verter GX7 ,
valve at max. Checking”,
value page 970 .
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21F6 Fuel Sys‐ • Adaption • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ value >= mg/rev Fuel Deliv‐
trol Sys‐ port Fuel 25.0 % • Continu‐ ery Unit -
tem "B" Injection • ECT @ cylinder ous GX1- . Re‐
Too Lean System block > 70° C fer to
Off Idle Too Lean • IAT @ manifold ⇒ “3.6.23
Bank 2 @ Part > -11° C Fuel Deliv‐
Load ery Unit
• AAT > -48° C GX1 ,
Checking”,
• lambda set point page 940 .
0.92 – 1.05 [-]
– Check the
• Lambda control fuel pres‐
closed loop inte‐ sure regula‐
grated air mass tor and re‐
> 30.0 g sidual pres‐
• Fuel mass 13.01 sure. Refer
– 36.01 mg/rev to appropri‐
ate repair
• Engine speed manual.
704 – 4,960
RPM – Check the
Fuel Injec‐
• Ethanol value tors (2 [B
n.a. Circuit]).
• Low dynamic Refer to
conditions: ⇒ “3.6.25
Fuel Injec‐
• Diff. engine tors (2 [B
speed vs. aver‐ Circuit]),
aged engine Checking”,
speed for engine page 944 .
speed dynamic
detection < 150 – Check the
RPM Fuel Pres‐
sure Sensor
• Diff. air mass vs. - G247- .
averaged air Refer to
mass for load ⇒ “3.6.27
dynamic detec‐ Fuel Pres‐
tion < 130.01 sure Sensor
mg/rev G247 ,
• Diff. between Checking”,
reference and page 948 .
actual fuel pres‐
sure, high side – Check in‐
<= 34,777.60 take system
kPa visually for
leaks (false
• Integrated air air).
mass > 15.0 –
70.0 g – Check the
Oxygen
• And Sensor 2
• Evap purge Before Cat‐
valve closed alytic Con‐
verter -
• Or GX11- . Re‐
fer to
• Canister load <= ⇒ “3.6.41
2.0 [-] Oxygen
Sensor 2
Before Cat‐
alytic Con‐
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge verter
valve at max. GX11 ,
value Checking”,
page 978 .
• Or
• Dependence on – Check the
canister purge Oxygen
min: Sensor 2
After Cata‐
• Lower limit of lytic Con‐
lambda control‐ verter -
ler output n.a. GX8- . Re‐
fer to
• Or ⇒ “3.6.40
Oxygen
• Upper limit of Sensor 2
lambda control‐ After Cata‐
ler output n.a. lytic Con‐
• And verter GX8 ,
Checking”,
• Evap purge flow page 976 .
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21F7 Fuel Sys‐ • Adaption • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ value <= mg/rev fuel pres‐
trol Sys‐ port Fuel -25.0 % • Continu‐ sure regula‐
tem "B" Injection • ECT @ cylinder ous tor and re‐
Too Rich System block > 70° C sidual pres‐
Off Idle Too Rich • IAT @ manifold sure. Refer
Bank 2 @ Part > -11° C to appropri‐
Load ate repair
• AAT > -48° C manual.
• lambda set point – Check the
0.92 – 1.05 [-] Fuel Injec‐
tors (2 [B
• Lambda control Circuit]).
closed loop inte‐ Refer to
grated air mass ⇒ “3.6.25
> 30.0 g Fuel Injec‐
• Fuel mass 13.01 tors (2 [B
– 36.01 mg/rev Circuit]),
Checking”,
• Engine speed page 944 .
704 – 4,960
RPM – Check the
Fuel Pres‐
• Ethanol value sure Sensor
n.a. - G247- .
• Low dynamic Refer to
conditions: ⇒ “3.6.27
Fuel Pres‐
• Diff. engine sure Sensor
speed vs. aver‐ G247 ,
aged engine Checking”,
speed for engine page 948 .
speed dynamic
detection < 150 – Check the
RPM Oxygen
Sensor 2
• Diff. air mass vs. Before Cat‐
averaged air alytic Con‐
mass for load verter -
dynamic detec‐ GX11- . Re‐
tion < 130.01 fer to
mg/rev ⇒ “3.6.41
• Diff. between Oxygen
reference and Sensor 2
actual fuel pres‐ Before Cat‐
sure, high side alytic Con‐
<= 34,777.60 verter
kPa GX11 ,
Checking”,
• Integrated air page 978 .
mass > 15.0 –
70.0 g – Check the
Oxygen
• And Sensor 2
• Evap purge After Cata‐
valve closed lytic Con‐
verter -
• Or GX8- . Re‐
fer to
• Canister load <= ⇒ “3.6.40
2.0 [-] Oxygen
Sensor 2
After Cata‐
lytic Con‐
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge verter GX8 ,
valve at max. Checking”,
value page 976 .
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21F8 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ mg/rev Fuel Deliv‐
trol Sys‐ port Fuel • Adaptive • Continu‐ ery Unit -
tem "B" Injection value >= • ECT @ cylinder ous GX1- . Re‐
Too Lean System n.a. mg/rev block > 70° C fer to
at Idle Too Lean • Case 2: • IAT @ manifold ⇒ “3.6.23
Bank 1 @ Idle > -11° C Fuel Deliv‐
• Adaptive ery Unit
value >= • AAT > -48° C GX1 ,
0.33 kg/h Checking”,
• lambda set point page 940 .
0.92 – 1.05 [-]
– Check the
• Lambda control fuel pres‐
closed loop inte‐ sure regula‐
grated air mass tor and re‐
> 30.0 g sidual pres‐
• Fuel mass 13.01 sure. Refer
– 36.01 mg/rev to appropri‐
ate repair
• Engine speed manual.
704 – 4,960
RPM – Check the
Fuel Injec‐
• Ethanol value tors (2 [B
n.a. Circuit]).
• Low dynamic Refer to
conditions: ⇒ “3.6.25
Fuel Injec‐
• Diff. engine tors (2 [B
speed vs. aver‐ Circuit]),
aged engine Checking”,
speed for engine page 944 .
speed dynamic
detection < 150 – Check the
RPM Fuel Pres‐
sure Sensor
• Diff. air mass vs. - G247- .
averaged air Refer to
mass for load ⇒ “3.6.27
dynamic detec‐ Fuel Pres‐
tion < 130.01 sure Sensor
mg/rev G247 ,
• Diff. between Checking”,
reference and page 948 .
actual fuel pres‐
sure, high side – Check in‐
<= 34,777.60 take system
kPa visually for
leaks (false
• Integrated air air).
mass > 15.0 –
70.0 g – Check the
Oxygen
• And Sensor 1
• Evap purge Before Cat‐
valve closed alytic Con‐
verter -
• Or GX10- . Re‐
fer to
• Canister load <= ⇒ “3.6.39
2.0 [-] Oxygen
Sensor 1
Before Cat‐
alytic Con‐
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge verter
valve at max. GX10 ,
value Checking”,
page 972 .
• Or
• Dependence on – Check the
canister purge Oxygen
min: Sensor 1
After Cata‐
• Lower limit of lytic Con‐
lambda control‐ verter -
ler output n.a. GX7- . Re‐
fer to
• Or ⇒ “3.6.38
Oxygen
• Upper limit of Sensor 1
lambda control‐ After Cata‐
ler output n.a. lytic Con‐
• And verter GX7 ,
Checking”,
• Evap purge flow page 970 .
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21F9 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ mg/rev fuel pres‐
trol Sys‐ port Fuel • Adaptive • Continu‐ sure regula‐
tem "B" Injection value <= • ECT @ cylinder ous tor and re‐
Too Rich System n.a. mg/rev block > 70° C sidual pres‐
at Idle Too Rich • Case 2: • IAT @ manifold sure. Refer
Bank 1 @ Idle > -11° C to appropri‐
• Adaptive ate repair
value <= • AAT > -48° C manual.
-0.33 kg/h
• lambda set point – Check the
0.92 – 1.05 [-] Fuel Injec‐
tors (2 [B
• Lambda control Circuit]).
closed loop inte‐ Refer to
grated air mass ⇒ “3.6.25
> 30.0 g Fuel Injec‐
• Fuel mass 13.01 tors (2 [B
– 36.01 mg/rev Circuit]),
Checking”,
• Engine speed page 944 .
704 – 4,960
RPM – Check the
Fuel Pres‐
• Ethanol value sure Sensor
n.a. - G247- .
• Low dynamic Refer to
conditions: ⇒ “3.6.27
Fuel Pres‐
• Diff. engine sure Sensor
speed vs. aver‐ G247 ,
aged engine Checking”,
speed for engine page 948 .
speed dynamic
detection < 150 – Check the
RPM Oxygen
Sensor 1
• Diff. air mass vs. Before Cat‐
averaged air alytic Con‐
mass for load verter -
dynamic detec‐ GX10- . Re‐
tion < 130.01 fer to
mg/rev ⇒ “3.6.39
• Diff. between Oxygen
reference and Sensor 1
actual fuel pres‐ Before Cat‐
sure, high side alytic Con‐
<= 34,777.60 verter
kPa GX10 ,
Checking”,
• Integrated air page 972 .
mass > 15.0 –
70.0 g – Check the
Oxygen
• And Sensor 1
• Evap purge After Cata‐
valve closed lytic Con‐
verter -
• Or GX7- . Re‐
fer to
• Canister load <= ⇒ “3.6.38
2.0 [-] Oxygen
Sensor 1
After Cata‐
lytic Con‐
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge verter GX7 ,
valve at max. Checking”,
value page 970 .
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21FA Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ mg/rev Fuel Deliv‐
trol Sys‐ port Fuel • Adaptive • Continu‐ ery Unit -
tem "B" Injection value >= • ECT @ cylinder ous GX1- . Re‐
Too Lean System n.a. mg/rev block > 70° C fer to
at Idle Too Lean • Case 2: • IAT @ manifold ⇒ “3.6.23
Bank 2 @ Idle > -11° C Fuel Deliv‐
• Adaptive ery Unit
value >= • AAT > -48° C GX1 ,
0.33 kg/h Checking”,
• lambda set point page 940 .
0.92 – 1.05 [-]
– Check the
• Lambda control fuel pres‐
closed loop inte‐ sure regula‐
grated air mass tor and re‐
> 30.0 g sidual pres‐
• Fuel mass 13.01 sure. Refer
– 36.01 mg/rev to appropri‐
ate repair
• Engine speed manual.
704 – 4,960
RPM – Check the
Fuel Injec‐
• Ethanol value tors (2 [B
n.a. Circuit]).
• Low dynamic Refer to
conditions: ⇒ “3.6.25
Fuel Injec‐
• Diff. engine tors (2 [B
speed vs. aver‐ Circuit]),
aged engine Checking”,
speed for engine page 944 .
speed dynamic
detection < 150 – Check the
RPM Fuel Pres‐
sure Sensor
• Diff. air mass vs. - G247- .
averaged air Refer to
mass for load ⇒ “3.6.27
dynamic detec‐ Fuel Pres‐
tion < 130.01 sure Sensor
mg/rev G247 ,
• Diff. between Checking”,
reference and page 948 .
actual fuel pres‐
sure, high side – Check the
<= 34,777.60 Oxygen
kPa Sensor 2
Before Cat‐
• Integrated air alytic Con‐
mass > 15.0 – verter -
70.0 g GX11- . Re‐
fer to
• And ⇒ “3.6.41
Oxygen
• Evap purge Sensor 2
valve closed Before Cat‐
• Or alytic Con‐
verter
• Canister load <= GX11 ,
2.0 [-] Checking”,
page 978 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge – Check the
valve at max. Oxygen
value Sensor 2
After Cata‐
• Or lytic Con‐
• Dependence on verter -
canister purge GX8- . Re‐
min: fer to
⇒ “3.6.40
• Lower limit of Oxygen
lambda control‐ Sensor 2
ler output n.a. After Cata‐
lytic Con‐
• Or verter GX8 ,
Checking”,
• Upper limit of page 976 .
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P21FB Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ mg/rev fuel pres‐
trol Sys‐ port Fuel • Adaptive • Continu‐ sure regula‐
tem "B" Injection value <= • ECT @ cylinder ous tor and re‐
Too Rich System n.a. mg/rev block > 70° C sidual pres‐
at Idle Too Rich • Case 2: • IAT @ manifold sure. Refer
Bank 2 @ Idle > -11° C to appropri‐
• Adaptive ate repair
value <= • AAT > -48° C manual.
-0.33 kg/h
• lambda set point – Check the
0.92 – 1.05 [-] Fuel Injec‐
tors (2 [B
• Lambda control Circuit]).
closed loop inte‐ Refer to
grated air mass ⇒ “3.6.25
> 30.0 g Fuel Injec‐
• Fuel mass 13.01 tors (2 [B
– 36.01 mg/rev Circuit]),
Checking”,
• Engine speed page 944 .
704 – 4,960
RPM – Check the
Fuel Pres‐
• Ethanol value sure Sensor
n.a. - G247- .
• Low dynamic Refer to
conditions: ⇒ “3.6.27
Fuel Pres‐
• Diff. engine sure Sensor
speed vs. aver‐ G247 ,
aged engine Checking”,
speed for engine page 948 .
speed dynamic
detection < 150 – Check the
RPM Oxygen
Sensor 2
• Diff. air mass vs. Before Cat‐
averaged air alytic Con‐
mass for load verter -
dynamic detec‐ GX11- . Re‐
tion < 130.01 fer to
mg/rev ⇒ “3.6.41
• Diff. between Oxygen
reference and Sensor 2
actual fuel pres‐ Before Cat‐
sure, high side alytic Con‐
<= 34,777.60 verter
kPa GX11 ,
Checking”,
• Integrated air page 978 .
mass > 15.0 –
70.0 g – Check the
Oxygen
• And Sensor 2
• Evap purge After Cata‐
valve closed lytic Con‐
verter -
• Or GX8- . Re‐
fer to
• Canister load <= ⇒ “3.6.40
2.0 [-] Oxygen
Sensor 2
After Cata‐
lytic Con‐
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Evap purge verter GX8 ,
valve at max. Checking”,
value page 976 .
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2237 Oxygen • Diff. pump • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage ar) ready Oxygen
Positive Front (VIP) vs. vir‐ • Continu‐ Sensor 1
Current Open Cir‐ tual ground • O2S ceramic ous Before Cat‐
Control cuit voltage temperature > alytic Con‐
Circuit/ Pump (VG) > 1.20 830° C verter -
Open Voltage V • For time >= 17.0 GX10- . Re‐
Bank 1 (VIP) s fer to
Sensor 1 • Diff. nernst ⇒ “3.6.39
voltage Oxygen
(VN) vs. vir‐ Sensor 1
tual ground Before Cat‐
voltage alytic Con‐
(VG) <= verter
1.20 V GX10 ,
• And Checking”,
page 972 .
• Choice of:
• Nernst volt‐
age (VN) >
4.40 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2.35
V
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent >
0.0115 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2240 Oxygen • Diff. pump • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage ar) ready Oxygen
Positive Front (VIP) vs. vir‐ • Continu‐ Sensor 2
Current Bank 2 tual ground • O2S ceramic ous Before Cat‐
Control Open Cir‐ voltage temperature > alytic Con‐
Circuit/ cuit (VG) > 1.20 830° C verter -
Open Pump V • For time >= 17.0 GX11- . Re‐
Bank 2 Voltage s fer to
Sensor 1 (VIP) • Diff. nernst ⇒ “3.6.41
voltage Oxygen
(VN) vs. vir‐ Sensor 2
tual ground Before Cat‐
voltage alytic Con‐
(VG) <= verter
1.20 V GX11 ,
• And Checking”,
page 978 .
• Choice of:
• Nernst volt‐
age (VN) >
4.40 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2.35
V
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent >
0.0115 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2243 Oxygen • Diff. pump • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage ar) ready Oxygen
Reference Front (VIP) vs. vir‐ • Continu‐ Sensor 1
Voltage Open Cir‐ tual ground • O2S ceramic ous Before Cat‐
Circuit/ cuit voltage temperature > alytic Con‐
Open Nernst (VG) <= 830° C verter -
Bank 1 Voltage 1.20 V • For time >= 17.0 GX10- . Re‐
Sensor 1 (VN) s fer to
• Diff. nernst ⇒ “3.6.39
voltage Oxygen
(VN) vs. vir‐ Sensor 1
tual ground Before Cat‐
voltage alytic Con‐
(VG) > 1.20 verter
V GX10 ,
• And Checking”,
page 972 .
• Choice of:
• Nernst volt‐
age (VN) >
4.40 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2.35
V
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent >
0.0115 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2247 Oxygen • Diff. pump • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage ar) ready Oxygen
Reference Front (VIP) vs. vir‐ • Continu‐ Sensor 2
Voltage Bank 2 tual ground • O2S ceramic ous Before Cat‐
Circuit/ Open Cir‐ voltage temperature > alytic Con‐
Open cuit (VG) <= 680° C verter -
Bank 2 Nernst 1.20 V • For time >= 17.0 GX11- . Re‐
Sensor 1 Voltage s fer to
(VN) • Diff. nernst ⇒ “3.6.41
voltage Oxygen
(VN) vs. vir‐ Sensor 2
tual ground Before Cat‐
voltage alytic Con‐
(VG) > 1.20 verter
V GX11 ,
• And Checking”,
page 978 .
• Choice of:
• Nernst volt‐
age (VN) >
4.40 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2.35
V
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent >
0.0115 A
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2251 Oxygen • Nernst volt‐ • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors age (VN) > ar) ready Oxygen
Negative Front 4.40 V • Continu‐ Sensor 1
Current Open Cir‐ • O2S ceramic ous Before Cat‐
Control cuit Virtu‐ • Or temperature > alytic Con‐
Circuit/ al Ground • 830° C verter -
Diff. pump
Open (VG) voltage • For time >= 17.0 GX10- . Re‐
Bank 1 (VIP) vs. vir‐ s fer to
Sensor 1 tual ground ⇒ “3.6.39
voltage Oxygen
(VG) > 2.35 Sensor 1
V Before Cat‐
alytic Con‐
• Diff. pump verter
voltage GX10 ,
(VIP) vs. vir‐ Checking”,
tual ground page 972 .
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent >
0.0115 A
• Or
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00 Ω
• And
• Choice of:
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) <=
1.20 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) <=
1.20 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2254 Oxygen • Nernst volt‐ • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors age (VN) > ar) ready Oxygen
Negative Front 4.40 V • Continu‐ Sensor 2
Current Bank 2 • O2S ceramic ous Before Cat‐
Control Open Cir‐ • Or temperature > alytic Con‐
Circuit/ cuit Virtu‐ • 830° C verter -
Diff. pump
Open al Ground voltage • For time >= 17.0 GX11- . Re‐
Bank 2 (VG) (VIP) vs. vir‐ s fer to
Sensor 1 tual ground ⇒ “3.6.41
voltage Oxygen
(VG) > 2.35 Sensor 2
V Before Cat‐
alytic Con‐
• Diff. pump verter
voltage GX11 ,
(VIP) vs. vir‐ Checking”,
tual ground page 978 .
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent >
0.0115 A
• Or
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00 Ω
• And
• Choice of:
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) <=
1.20 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) <=
1.20 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
P2257 Secon‐ • Output volt‐ • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air age (hard‐ Secondary
tem Con‐ Injection ware val‐ • Actuator com‐ • Continu‐ Air Injection
trol "A" Cir‐ Pump ues) < 1.92 manded off ous Pump Re‐
cuit Low Relay – 2.21 V lay - -
Short To J299-- /
Ground Secondary
Air Injection
Pump Mo‐
tor - V101- .
Refer to
⇒ “3.6.42
Secondary
Air Injection
Pump Re‐
lay J299 /
Secondary
Air Injection
Pump Mo‐
tor V101 ,
Checking”,
page 982 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2258 Secon‐ • Actuator • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air tempera‐ Secondary
tem Con‐ Injection ture > 160 – • Actuator com‐ • Continu‐ Air Injection
trol "A" Cir‐ Pump 200° C manded on ous Pump Re‐
cuit High Relay lay - -
Short To • Or J299-- /
Battery • Output cur‐ Secondary
Plus rent (hard‐ Air Injection
ware val‐ Pump Mo‐
ues) > 1.0 – tor - V101- .
2.0 A Refer to
⇒ “3.6.42
Secondary
Air Injection
Pump Re‐
lay J299 /
Secondary
Air Injection
Pump Mo‐
tor V101 ,
Checking”,
page 982 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2270 Oxygen • O2S rear • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors voltage < tions: (FTP75: Oxygen
Signal Rear Sig‐ 0.82 V 50.0) s Sensor 1
Biased/ nal • Catalyst monitor After Cata‐
Stuck Range • Intrusive lambda modula‐ • Once / lytic Con‐
Lean Bank Check lambda tion request ac‐ DCY verter -
1 Sensor 2 ramp lean < tive GX7- . Re‐
0.84 [-] fer to
• Vehicle speed
>= 0 mph ⇒ “3.6.38
Oxygen
• BARO >= 63.0 Sensor 1
kPa After Cata‐
lytic Con‐
• Catalyst over‐ verter GX7 ,
heating protec‐ Checking”,
tion not active page 970 .
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated MAF,
catalyst temp.
conditions fulfil‐
led >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• MAF per cylin‐
der per stroke,
lower range >=
70.01 – 120.01
mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• MAF per cylin‐
der per stroke,
upper range <=
460.01 – 560.0
mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Deviation actual
and target MAF
< 60.0 mg/rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated MAF
after dynamic
conditions are
fulfilled > 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated MAF
to start diagno‐
sis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a.
• O2S heater rear
active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve ( closing
time ) < n.a. s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled MAF-
integral > 0.0 [g
• Integrated MAF
per cylinder >=
2.20 – 2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2271 Oxygen • O2S rear • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors voltage > tions: (FTP75: Oxygen
Signal Rear Sig‐ 0.15 V 50.0) s Sensor 1
Biased/ nal • Catalyst monitor After Cata‐
Stuck Rich Range • Intrusive lambda modula‐ • Once / lytic Con‐
Bank 1 Check lambda tion request ac‐ DCY verter -
Sensor 2 ramp lean > tive GX7- . Re‐
1.16 [-] fer to
• Intrusive lambda
ramp request ⇒ “3.6.38
active Oxygen
Sensor 1
• Vehicle speed After Cata‐
>= 0 mph lytic Con‐
verter GX7 ,
• BARO >= 63.0 Checking”,
kPa page 970 .
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated MAF,
catalyst temp.
conditions fulfil‐
led >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• MAF per cylin‐
der per stroke,
lower range >=
70.01 – 120.01
mg/rev
• MAF per cylin‐
der per stroke,
upper range <=
460.01 – 560.0
mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Deviation actual
and target MAF
< 60.0 mg/rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated MAF
after dynamic
conditions are
fulfilled > 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated MAF
to start diagno‐
sis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Coasting func‐
tion n.a.
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time ) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled MAF-
integral > 0.0 [g
• Integrated MAF
per cylinder >=
2.20 – 2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2272 Oxygen • O2S rear • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors voltage < tions: (FTP75: Oxygen
Signal Rear 0.82 V 50.0) s Sensor 2
Biased/ Bank 2 • Catalyst monitor After Cata‐
Stuck Signal • Intrusive lambda modula‐ • Once / lytic Con‐
Lean Bank Range lambda tion request ac‐ DCY verter -
2 Sensor 2 Check ramp lean < tive GX8- . Re‐
0.84 [-] fer to
• Vehicle speed
>= 0 mph ⇒ “3.6.40
Oxygen
• BARO >= 63.0 Sensor 2
kPa After Cata‐
lytic Con‐
• Catalyst over‐ verter GX8 ,
heating protec‐ Checking”,
tion not active page 976 .
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated MAF,
catalyst temp.
conditions fulfil‐
led >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• MAF per cylin‐
der per stroke,
lower range >=
70.01 – 120.01
mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• MAF per cylin‐
der per stroke,
upper range <=
460.01 – 560.0
mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Deviation actual
and target MAF
< 60.0 mg/rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated MAF
after dynamic
conditions are
fulfilled > 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated MAF
to start diagno‐
sis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
• Coasting func‐
tion n.a.
• O2S heater rear
active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time ) < n.a. s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled MAF-
integral > 0.0 [g
• Integrated MAF
per cylinder >=
2.20 – 2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2273 Oxygen • O2S rear • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors voltage > tions: (FTP75: Oxygen
Signal Rear 0.15 V 50.0) s Sensor 2
Biased/ Bank 2 • Catalyst monitor After Cata‐
Stuck Rich Signal • Intrusive lambda modula‐ • Once / lytic Con‐
Bank 2 Range lambda tion request ac‐ DCY verter -
Sensor 2 Check ramp lean > tive GX8- . Re‐
1.16 [-] fer to
• Intrusive lambda
ramp request ⇒ “3.6.40
active Oxygen
Sensor 2
• Vehicle speed After Cata‐
>= 0 mph lytic Con‐
verter GX8 ,
• BARO >= 63.0 Checking”,
kPa page 976 .
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 550° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated MAF,
catalyst temp.
conditions fulfil‐
led >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• MAF per cylin‐
der per stroke,
lower range >=
70.01 – 120.01
mg/rev
• MAF per cylin‐
der per stroke,
upper range <=
460.01 – 560.0
mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Deviation actual
and target MAF
< 60.0 mg/rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated MAF
after dynamic
conditions are
fulfilled > 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated MAF
to start diagno‐
sis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 20.0
%
• Proportional
part of secon‐
dary fuel control
loop < 0.10 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Coasting func‐
tion n.a.
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time ) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled MAF-
integral > 0.0 [g
• Integrated MAF
per cylinder >=
2.20 – 2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2279 Intake Air • Diff. set • Engine running • 0.0 s • 2 DCY – Check the
MAP/MAF System point MAP Intake Air
- Throttle Rationali‐ upstream • Time after en‐ • Continu‐ Tempera‐
Position ty Check supercharg‐ gine start > 10.0 ous ture Sensor
Correla‐ Low er vs. meas‐ s - G42- /
tion ured MAP • Barometric Manifold
upstream pressure 63.0 – Absolute
supercharg‐ 105.0 kPa Pressure
er < -15.0 Sensor -
kPa • Engine speed 0 G71- . Refer
– 8,160 RPM to
• For time >= ⇒ “3.6.30
5.0 s • IAT @ manifold Intake Air
> 5° C Tempera‐
ture Sensor
• ECT @ cylinder G42 / Mani‐
block > -48° C fold Abso‐
• Diff. engine lute Pres‐
speed vs. fil‐ sure Sensor
tered engine G71 ,
speed for engine Checking”,
speed dynamic page 954 .
detection < 96
RPM .
• Diff. air mass set
point vs. filtered
air mass set
point for load dy‐
namic detection
< 15.01 mg/rev
• Engine speed >
512; < 512 RPM
• Fuel cut off not
active
• Pressure gradi‐
ent @ pressure
sensor up‐
stream super‐
charger
-8,291.80 –
8,291.50 kPa/s
• Gradient super‐
charger boost
pressure
-1,500.0 –
1,500.0 kPa/s
• Engine speed
limitation not ac‐
tive
• Fast throttle
adaptation fin‐
ished
• Throttle actuator
commanded on
• Modeled pres‐
sure quotient >
0.30; <= 1.00 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2300 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils rent in ON 512 RPM Ignition Coil
Coil "A" Short To state (hard‐ • Continu‐ 1 With Pow‐
Primary Ground ware val‐ • ECT @ cylinder ous er Output
Control ues) > 50 – block > -30° C Stage -
Circuit 100.0 mA • Engine stop not N70- . Refer
Low active to
⇒ “3.6.29
Ignition
Coils With
Power Out‐
put Stage ,
Checking”,
page 952 .
P2301 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils by inactive 512 RPM Ignition Coil
Coil "A" Short To low side • Continu‐ 1 With Pow‐
Primary Battery switch in • Engine stop not ous er Output
Control Plus ATIC: active Stage -
Circuit N70- . Refer
High • Output volt‐ • Actuator com‐
to
age in OFF manded off
⇒ “3.6.29
state (hard‐ Ignition
ware val‐ Coils With
ues) > 4.95 Power Out‐
– 5.285 V put Stage ,
Checking”,
• Diagnosis • Engine speed > page 952 .
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2302 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils age in OFF 512 RPM Ignition Coil
Coil "A" Open Cir‐ state, lower • Continu‐ 1 With Pow‐
Secondary cuit range >= • ECT @ cylinder ous er Output
Circuit 1.92 – 2.21 block > -30° C Stage -
V • Engine stop not N70- . Refer
active to
• Output volt‐ ⇒ “3.6.29
age in OFF Ignition
state, upper Coils With
range Power Out‐
(hardware put Stage ,
values) <= Checking”,
2.85 – 3.25 page 952 .
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2303 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils rent in ON 512 RPM Ignition Coil
Coil "B" Short To state (hard‐ • Continu‐ 2 With Pow‐
Primary Ground ware val‐ • ECT @ cylinder ous er Output
Control ues) > 50 – block > -30° C Stage -
Circuit 100.0 mA • Engine stop not N127- . Re‐
Low active fer to
⇒ “3.6.29
Ignition
Coils With
Power Out‐
put Stage ,
Checking”,
page 952 .
P2304 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils by inactive 512 RPM Ignition Coil
Coil "B" Short To low side • Continu‐ 2 With Pow‐
Primary Battery switch in • Engine stop not ous er Output
Control Plus ATIC: active Stage -
Circuit N127- . Re‐
High • Output volt‐ • Actuator com‐
fer to
age in OFF manded off
⇒ “3.6.29
state (hard‐ Ignition
ware val‐ Coils With
ues) > 4.95 Power Out‐
– 5.285 V put Stage ,
Checking”,
• Diagnosis • Engine speed > page 952 .
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2305 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils age in OFF 512 RPM Ignition Coil
Coil "B" Open Cir‐ state, lower • Continu‐ 2 With Pow‐
Secondary cuit range >= • ECT @ cylinder ous er Output
Circuit 1.92 – 2.21 block > -30° C Stage -
V • Engine stop not N127- . Re‐
active fer to
• Output volt‐ ⇒ “3.6.29
age in OFF Ignition
state, upper Coils With
range Power Out‐
(hardware put Stage ,
values) <= Checking”,
2.85 – 3.25 page 952 .
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2306 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils rent in ON 512 RPM Ignition Coil
Coil "C" Short To state (hard‐ • Continu‐ 3 With Pow‐
Primary Ground ware val‐ • ECT @ cylinder ous er Output
Control ues) > 50 – block > -30° C Stage -
Circuit 100.0 mA • Engine stop not N291- . Re‐
Low active fer to
⇒ “3.6.29
Ignition
Coils With
Power Out‐
put Stage ,
Checking”,
page 952 .
P2307 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils by inactive 512 RPM Ignition Coil
Coil "C" Short To low side • Continu‐ 3 With Pow‐
Primary Battery switch in • Engine stop not ous er Output
Control Plus ATIC: active Stage -
Circuit N291- . Re‐
High • Output volt‐ • Actuator com‐
fer to
age in OFF manded off
⇒ “3.6.29
state (hard‐ Ignition
ware val‐ Coils With
ues) > 4.95 Power Out‐
– 5.285 V put Stage ,
Checking”,
• Diagnosis • Engine speed > page 952 .
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2308 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils age in OFF 512 RPM Ignition Coil
Coil "C" Open Cir‐ state, lower • Continu‐ 3 With Pow‐
Secondary cuit range >= • ECT @ cylinder ous er Output
Circuit 1.92 – 2.21 block > -30° C Stage -
V • Engine stop not N291- . Re‐
active fer to
• Output volt‐ ⇒ “3.6.29
age in OFF Ignition
state, upper Coils With
range Power Out‐
(hardware put Stage ,
values) <= Checking”,
2.85 – 3.25 page 952 .
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2309 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils rent in ON 512 RPM Ignition Coil
Coil "D" Short To state (hard‐ • Continu‐ 4 With Pow‐
Primary Ground ware val‐ • ECT @ cylinder ous er Output
Control ues) > 50 – block > -30° C Stage -
Circuit 100.0 mA • Engine stop not N292- . Re‐
Low active fer to
⇒ “3.6.29
Ignition
Coils With
Power Out‐
put Stage ,
Checking”,
page 952 .
P2310 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils by inactive 512 RPM Ignition Coil
Coil "D" Short To low side • Continu‐ 4 With Pow‐
Primary Battery switch in • Engine stop not ous er Output
Control Plus ATIC: active Stage -
Circuit N292- . Re‐
High • Output volt‐ • Actuator com‐
fer to
age in OFF manded off
⇒ “3.6.29
state (hard‐ Ignition
ware val‐ Coils With
ues) > 4.95 Power Out‐
– 5.285 V put Stage ,
Checking”,
• Diagnosis • Engine speed > page 952 .
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2311 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils age in OFF 512 RPM Ignition Coil
Coil "D" Open Cir‐ state, lower • Continu‐ 4 With Pow‐
Secondary cuit range >= • ECT @ cylinder ous er Output
Circuit 1.92 – 2.21 block > -30° C Stage -
V • Engine stop not N292- . Re‐
active fer to
• Output volt‐ ⇒ “3.6.29
age in OFF Ignition
state, upper Coils With
range Power Out‐
(hardware put Stage ,
values) <= Checking”,
2.85 – 3.25 page 952 .
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2312 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils rent in ON 512 RPM Ignition Coil
Coil "E" Short To state (hard‐ • Continu‐ 5 With Pow‐
Primary Ground ware val‐ • ECT @ cylinder ous er Output
Control ues) > 50 – block > -30° C Stage -
Circuit 100.0 mA • Engine stop not N323- . Re‐
Low active fer to
⇒ “3.6.29
Ignition
Coils With
Power Out‐
put Stage ,
Checking”,
page 952 .
P2313 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils by inactive 512 RPM Ignition Coil
Coil "E" Short To low side • Continu‐ 5 With Pow‐
Primary Battery switch in • Engine stop not ous er Output
Control Plus ATIC: active Stage -
Circuit N323- . Re‐
High • Output volt‐ • Actuator com‐
fer to
age in OFF manded off
⇒ “3.6.29
state (hard‐ Ignition
ware val‐ Coils With
ues) > 4.95 Power Out‐
– 5.285 V put Stage ,
Checking”,
• Diagnosis • Engine speed > page 952 .
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2314 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils age in OFF 512 RPM Ignition Coil
Coil "E" Open Cir‐ state, lower • Continu‐ 5 With Pow‐
Secondary cuit range >= • ECT @ cylinder ous er Output
Circuit 1.92 – 2.21 block > -30° C Stage -
V • Engine stop not N323- . Re‐
active fer to
• Output volt‐ ⇒ “3.6.29
age in OFF Ignition
state, upper Coils With
range Power Out‐
(hardware put Stage ,
values) <= Checking”,
2.85 – 3.25 page 952 .
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2315 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils rent in ON 512 RPM Ignition Coil
Coil "F" Short To state (hard‐ • Continu‐ 6 With Pow‐
Primary Ground ware val‐ • ECT @ cylinder ous er Output
Control ues) > 50 – block > -30° C Stage -
Circuit 100.0 mA • Engine stop not N324- . Re‐
Low active fer to
⇒ “3.6.29
Ignition
Coils With
Power Out‐
put Stage ,
Checking”,
page 952 .
P2316 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils by inactive 512 RPM Ignition Coil
Coil "F" Short To low side • Continu‐ 6 With Pow‐
Primary Battery switch in • Engine stop not ous er Output
Control Plus ATIC: active Stage -
Circuit N324- . Re‐
High • Output volt‐ • Actuator com‐
fer to
age in OFF manded off
⇒ “3.6.29
state (hard‐ Ignition
ware val‐ Coils With
ues) > 4.95 Power Out‐
– 5.285 V put Stage ,
Checking”,
• Diagnosis • Engine speed > page 952 .
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2317 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the
Ignition Coils age in OFF 512 RPM Ignition Coil
Coil "F" Open Cir‐ state, lower • Continu‐ 6 With Pow‐
Secondary cuit range >= • ECT @ cylinder ous er Output
Circuit 1.92 – 2.21 block > -30° C Stage -
V • Engine stop not N324- . Re‐
active fer to
• Output volt‐ ⇒ “3.6.29
age in OFF Ignition
state, upper Coils With
range Power Out‐
(hardware put Stage ,
values) <= Checking”,
2.85 – 3.25 page 952 .
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P23F2 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 1 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 1
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
"B" Air- Injection vidual lamb‐ ous tor 2 -
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – N532- . Re‐
Imbalance balance: 10.0 % 1,389.0 mg/rev fer to
Out Of • Engine speed ⇒ “3.6.25
Range 600 – 8,160 Fuel Injec‐
High RPM tors (2 [B
Circuit]),
• Lambda value Checking”,
vs. modeled page 944 .
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P23F3 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 2 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 2
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
"B" Air- Injection vidual lamb‐ ous tor 2 -
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – N533- . Re‐
Imbalance balance: 10.0 % 1,389.0 mg/rev fer to
Out Of • Engine speed ⇒ “3.6.25
Range 600 – 8,160 Fuel Injec‐
High RPM tors (2 [B
Circuit]),
• Lambda value Checking”,
vs. modeled page 944 .
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P23F4 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 3 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 3
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
"B" Air- Injection vidual lamb‐ ous tor 2 -
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – N534- . Re‐
Imbalance balance: 10.0 % 1,389.0 mg/rev fer to
Out Of • Engine speed ⇒ “3.6.25
Range 600 – 8,160 Fuel Injec‐
High RPM tors (2 [B
Circuit]),
• Lambda value Checking”,
vs. modeled page 944 .
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P23F5 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 4 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 4
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
"B" Air- Injection vidual lamb‐ ous tor 2 -
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – N535- . Re‐
Imbalance balance: 10.0 % 1,389.0 mg/rev fer to
Out Of • Engine speed ⇒ “3.6.25
Range 600 – 8,160 Fuel Injec‐
High RPM tors (2 [B
Circuit]),
• Lambda value Checking”,
vs. modeled page 944 .
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P23F6 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 5 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 5
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
"B" Air- Injection vidual lamb‐ ous tor 2 -
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – N536- . Re‐
Imbalance balance: 10.0 % 1,389.0 mg/rev fer to
Out Of • Engine speed ⇒ “3.6.25
Range 600 – 8,160 Fuel Injec‐
High RPM tors (2 [B
Circuit]),
• Lambda value Checking”,
vs. modeled page 944 .
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P23F7 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 6 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 6
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injec‐
"B" Air- Injection vidual lamb‐ ous tor 2 -
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – N537- . Re‐
Imbalance balance: 10.0 % 1,389.0 mg/rev fer to
Out Of • Engine speed ⇒ “3.6.25
Range 600 – 8,160 Fuel Injec‐
High RPM tors (2 [B
Circuit]),
• Lambda value Checking”,
vs. modeled page 944 .
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 17.0 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 34.0 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2414 Oxygen • Pump cur‐ • O2S front ready • 10.0 s • 2 DCY – Check the
O2 Sensor Sensors rent correc‐ Oxygen
Exhaust Front Ra‐ tion (nernst- • Fuel cut off not • Continu‐ Sensor 1
Sample tionality cell) > 3.6 active ous Before Cat‐
Error Bank Check mA • Cylinder shut off alytic Con‐
1 Sensor 1 not active verter -
GX10- . Re‐
• Injection mode fer to
change (DFI/ ⇒ “3.6.39
MFI) not active Oxygen
Sensor 1
• Depending on Before Cat‐
engine state: alytic Con‐
verter
• Engine part load GX10 ,
• Or Checking”,
page 972 .
• Engine full load
• Or
• Engine idle
• For time >= 3.0 s
P2415 Oxygen • Pump cur‐ • O2S front ready • 10.0 s • 2 DCY – Check the
O2 Sensor Sensors rent correc‐ Oxygen
Exhaust Front tion (nernst- • Fuel cut off not • Continu‐ Sensor 2
Sample Bank 2 cell) > 3.6 active ous Before Cat‐
Error Bank Rationali‐ mA • Cylinder shut off alytic Con‐
2 Sensor 1 ty Check not active verter -
GX11- . Re‐
• Injection mode fer to
change (DFI/ ⇒ “3.6.41
MFI) not active Oxygen
Sensor 2
• Depending on Before Cat‐
engine state: alytic Con‐
• Engine part load verter
GX11 ,
• Or Checking”,
page 978 .
• Engine full load
• Or
• Engine idle
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2440 Secon‐ • Diff. lambda • ECT @ cylinder • 0.02 s • 2 DCY – Check the
AIR Sys‐ dary Air controller @ block @ engine Secondary
tem System closed sec‐ start 5 – 50° C • Once / Air Injection
Switching Stuck ondary air DCY Pump Re‐
Valve Open valve with • AAT @ engine lay - J299- /
Stuck running start >= 5° C Secondary
Open secondary • Time after en‐ Air Injection
Bank 1 air pump vs. gine start >= Pump Mo‐
lambda 22.0 –120.0 s tor - -
controller @ V101-- . Re‐
closed sec‐ • Fuel cut off not fer to
ondary air active ⇒ “3.6.42
valve with‐ Secondary
out running • O2S front ready Air Injection
secondary MAF <= Pump Re‐
air pump > 2,047.97 kg/h lay J299 /
20.0 % Secondary
• Air mass (en‐ Air Injection
gine load), lower Pump Mo‐
range >= 0.0 – tor V101 ,
82.0 mg/rev Checking”,
• Air mass (en‐ page 982 .
gine load), up‐
per range <= – Check the
452.0 mg/rev combina‐
tion valve
• Engine speed, for secon‐
lower range >= dary air in‐
800 – 8,160 jection. Re‐
RPM fer to appro‐
priate repair
• Engine speed, manual.
upper range <=
3,008 RPM
• Additional mass
fuel flow for wall
fuel liquid film
-6.0 – 6.0 mg/rev
• O2S front > 2.0
[-]
• Modeled pres‐
sure quotient <=
1.0 [-]
• AIR system
commanded on
• Low dynamic
conditions
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 220
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 110.0 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. lambda vs.
averaged lamb‐
da for lambda
dynamic detec‐
tion < 1.10 [-]
• Integrated MAF
> 10.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2442 Secon‐ • Diff. lambda • ECT @ cylinder • 0.02 s • 2 DCY – Check the
AIR Sys‐ dary Air controller @ block @ engine Secondary
tem System 2 closed sec‐ start 5 – 50° C • Once / Air Injection
Switching Stuck ondary air DCY Pump Re‐
Valve Open valve with • AAT @ engine lay - J299- /
Stuck running start >= 5° C Secondary
Open secondary • Time after en‐ Air Injection
Bank 2 air pump vs. gine start >= Pump Mo‐
lambda 22.0 –120.0 s tor - -
controller @ V101-- . Re‐
closed sec‐ • Fuel cut off not fer to
ondary air active ⇒ “3.6.42
valve with‐ Secondary
out running • O2S front ready Air Injection
secondary MAF <= Pump Re‐
air pump > 2,047.97 kg/h lay J299 /
20.0 % Secondary
• Air mass (en‐ Air Injection
gine load), lower Pump Mo‐
range >= 0.0 – tor V101 ,
82.0 mg/rev Checking”,
• Air mass (en‐ page 982 .
gine load), up‐
per range <= – Check the
452.0 mg/rev combina‐
tion valve
• Engine speed, for secon‐
lower range >= dary air in‐
800 – 8,160 jection. Re‐
RPM fer to appro‐
priate repair
• Engine speed, manual.
upper range <=
3,008 RPM
• Additional mass
fuel flow for wall
fuel liquid film
-6.0 – 6.0 mg/rev
• O2S front > 2.0
[-]
• Modeled pres‐
sure quotient <=
1.0 [-]
• AIR system
commanded on
• Low dynamic
conditions
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 220
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 110.0 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. lambda vs.
averaged lamb‐
da for lambda
dynamic detec‐
tion < 1.10 [-]
• Integrated MAF
> 10.0 g
– Check the
Low Fuel
Pressure
Sensor -
G410- . Re‐
fer to
⇒ “3.6.36
Low Fuel
Pressure
Sensor
G410 ,
Checking”,
page 965 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2540 Fuel Sys‐ • Depending • Engine warm-up • 1.0 s • 2 DCY – Check the
Low Pres‐ tem Pres‐ on Multiport not active pressure in
sure Fuel sure Sen‐ Fuel Injec‐ • Continu‐ the fuel sys‐
System sor, Low tion: • Catalyst heating ous tem for out
Sensor Pressure not active of spec con‐
Circuit Side Ra‐ • Actual and ditions be‐
Range/ tionality adapted I- • Engine no full
fore diag‐
part of elec‐ load
Perform‐ Check nosing the
ance High tric fuel • Lambda control pressure
pump con‐ active sensor. Re‐
troller fer to Fuel
(PWM sig‐ • Catalyst over‐ System Me‐
nal) < -20.0 heating protec‐ chanical
% tion not active Testing in
• Or ⇒ “3.1 Pre‐
• Catalyst purge liminary
not active
• Diff. fuel Check”,
pressure • Lambda control page 20 .
set point vs. closed loop
actual fuel – Check the
pressure < • Canister load <= Low Fuel
-19.90 kPa 0.50 [-] Pressure
Sensor -
• And • Diff. actual fuel G410- . Re‐
mass set point fer to
• Lambda vs. filtered fuel ⇒ “3.6.36
controller mass set point < Low Fuel
included 7.50 mg/rev Pressure
correction
• Time after en‐ Sensor
and adap‐
gine start > 15.0 G410 ,
tion > 20.0
s Checking”,
% page 965 .
• For time >= • ECT @ cylinder
15.0 s block -48° C
• And • And
• Depending • MFI part of injec‐
on high ted fuel >= 0.70
pressure [-]
Direct Fuel • Fuel mass set
Injection: point for low
• Actual and pressure-part
adapted I- 3.01 – 29.99 mg/
part of elec‐ rev
tric fuel
pump con‐ • For time >= 3.5 s
troller • And
(PWM sig‐
nal) < • Fuel mass set
-12.50 % point for low
pressure-part
• Or 3.01 – 50.00 mg/
rev
• Diff. fuel
pressure • For time >= 3.5 s
set point vs.
actual fuel
pressure <
-19.90 kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Lambda
controller
included
correction
and adap‐
tion < 12.50
%
• For time >=
15.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Fuel Sys‐ • Depending
tem Pres‐ on Multiport
sure Sen‐ Fuel Injec‐
sor, Low tion:
Pressure
Side Ra‐ • Actual and
tionality adapted I-
Check part of elec‐
Low tric fuel
pump con‐
troller
(PWM sig‐
nal) > 28.0
%
• Or
• Diff. fuel
pressure
set point vs.
actual fuel
pressure >
49.88 kPa
• And
• Lambda
controller
included
correction
and adap‐
tion < -20.0
%
• For time >=
10.0 s
• And
• Depending
on high
pressure
Direct Fuel
Injection:
• Actual and
adapted I-
part of elec‐
tric fuel
pump con‐
troller
(PWM sig‐
nal) > 24.90
%
• Or
• Diff. fuel
pressure
set point vs.
actual fuel
pressure >
49.88 kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Lambda
controller
included
correction
and adap‐
tion < 12.50
%
• For time >=
15.0 s
– Check the
Low Fuel
Pressure
Sensor -
G410- . Re‐
fer to
⇒ “3.6.36
Low Fuel
Pressure
Sensor
G410 ,
Checking”,
page 965 .
P2579 Super‐ • Ratio be‐ • Supercharger • 0.5 s • 2 DCY – Check the
Turbo‐ charger tween su‐ clutch closed >= Turbo‐
charger/ Speed percharger 0.5 s • Continu‐ charger
Super‐ Sensor speed vs. ous Speed Sen‐
charger Rationali‐ engine • Engine speed > sor 1 -
Speed ty Check speed < 0.0 700 RPM G688- . Re‐
Sensor "A" [-] • Gradient engine fer to
Circuit speed -992.0 – ⇒ “3.6.46
Range/ • Or Turbo‐
2,016.0 rpm/s
Perform‐ • Ratio be‐ charger
ance tween su‐ Speed Sen‐
percharger sor 1 G688 ,
speed vs. Checking”,
engine page 990 .
speed >
2.75 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2580 Super‐ • Super‐ • Engine speed > • 0.5 s • 2 DCY – Check the
Turbo‐ charger charger 800 RPM Turbo‐
charger/ Speed speed sen‐ • Continu‐ charger
Super‐ Sensor sor output • Engine speed ous Speed Sen‐
charger Signal frequency < -704.0 – 704.0 sor 1 -
Speed Check 2.0 Hz rpm/s G688- . Re‐
Sensor "A" • ECT @ cylinder fer to
Circuit block > 0° C ⇒ “3.6.46
Low Turbo‐
• Supercharger charger
MAF > 40.0 kg/h Speed Sen‐
sor 1 G688 ,
Checking”,
page 990 .
P25D9 CAN: • Instrument • 0.5 s • 2 DCY – Refer to ap‐
Fuel Level Fuel Lev‐ cluster propriate
Sensor "C" el Sensor module sig‐ • Continu‐ wiring dia‐
Circuit 3 CAN nal: short to ous gram. If fuel
Low Commu‐ ground fail‐ level sensor
nication ure and circuitry
With In‐ are ok, then
strument • Instrument replace the
Cluster cluster instrument
Module module sig‐ cluster. Re‐
nal: signal fer to appro‐
range priate repair
check fail‐ manual.
ure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P25EA Super‐ • Ratio be‐ • Supercharger • 0.5 s • 2 DCY – Check the
Super‐ charger tween su‐ clutch open Compres‐
charger (SC) percharger commanded on • Continu‐ sor Magnet‐
Discon‐ Clutch speed vs. ous ic Clutch -
nect Actuator engine • Gradient of en‐ N421- . Re‐
Clutch Function‐ speed > gine speed < fer to
Stuck al Check 2.10 [-] 1,504.0 RPM/s ⇒ “3.6.12
Closed Stuck • Engine speed > Compres‐
Close 550 RPM sor Magnet‐
ic Clutch
• For time > 49.0 s N421 ,
Checking”,
page 918 .
P25EB Super‐ • SC clutch • Actuator com‐ • 2.0 s • 2 DCY – Check the
Super‐ charger actuator manded off Compres‐
charger (SC) voltage 2.0 • Continu‐ sor Magnet‐
Discon‐ Clutch – 3.0 V ous ic Clutch -
nect Actuator N421- . Re‐
Clutch Cir‐ Open Cir‐ fer to
cuit cuit ⇒ “3.6.12
Range/ Compres‐
Perform‐ sor Magnet‐
ance ic Clutch
N421 ,
Checking”,
page 918 .
P25EC Super‐ • SC clutch • Actuator com‐ • 2.0 s • 2 DCY – Check the
Super‐ charger actuator manded off Compres‐
charger (SC) voltage < • Continu‐ sor Magnet‐
Discon‐ Clutch 2.0 V ous ic Clutch -
nect Actuator N421- . Re‐
Clutch Cir‐ Short To fer to
cuit Low Ground ⇒ “3.6.12
Compres‐
sor Magnet‐
ic Clutch
N421 ,
Checking”,
page 918 .
P25ED Super‐ • SC clutch • Actuator com‐ • 2.0 s • 2 DCY – Check the
Super‐ charger actuator manded on Compres‐
charger (SC) current > • Continu‐ sor Magnet‐
Discon‐ Clutch 9.0 A ous ic Clutch -
nect Actuator N421- . Re‐
Clutch Cir‐ Short To fer to
cuit High Battery ⇒ “3.6.12
Plus Compres‐
sor Magnet‐
ic Clutch
N421 ,
Checking”,
page 918 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2610 Engine • Difference • Case 1: • 10.0 ms • 2 DCY – Replace the
ECM/PCM Off Time between faulty En‐
Engine Off Rationali‐ engine-off • ECM keep alive • Once / gine Control
Timer Per‐ ty Check time and time active DCY Module .
formance ECM keep • Engine off timer Refer to ap‐
alive-time > reset not active propriate
12.0 s time delay >= repair man‐
1.0 s ual.
• Or
• Engine off • Case 2:
time (hard‐ • Delay timer for
ware val‐ acquisition of
ues) not val‐ engine off (hard‐
id ware values) > 0
s
• Case 3:
• Power latch di‐
agnosis active
• And
• Time after en‐
gine stop <
47.78 h
• Engine off timer
active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Engine • ECM inter‐ • ECM internal • 1.3 s
Off Time nal timer in‐ timer reset not
ECM In‐ itialization active • Continu‐
ternal failure ous
Timer • SPI communica‐
Check • Or tion failure after
reset not detec‐
• ECM inter‐ ted
nal timer
communi‐
cation fail‐
ure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2626 Oxygen • Case 1: • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors ar) ready Oxygen
Pumping Front • O2S front > • Once / Sensor 1
Current Open Cir‐ 4,644.0 Ω • O2S ceramic DCY Before Cat‐
Trim Cir‐ cuit temperature > alytic Con‐
• And 830° C
cuit/Open Nernst verter -
Bank 1 Voltage • Choice of: • For time >= 17.0 GX10- . Re‐
Sensor 1 (VN) s fer to
• Diff. pump ⇒ “3.6.39
voltage Oxygen
(VIP) vs. vir‐ Sensor 1
tual ground Before Cat‐
voltage alytic Con‐
(VG) <= verter
1.20 V GX10 ,
Checking”,
• Or page 972 .
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
• Case 2:
• Nernst volt‐
age (VN) >
4.4 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2,35
V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.6 V
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.1
V
• Or
• Pump cur‐
rent >
0.0115 A
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
P2629 Oxygen • Case 1: • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors ar) ready Oxygen
Pumping Front • O2S front > • Once / Sensor 2
Current Bank 2 4,644.0 Ω • O2S ceramic DCY Before Cat‐
Trim Cir‐ Open Cir‐ temperature > alytic Con‐
• And 830° C
cuit/Open cuit verter -
Bank 2 Nernst • Choice of: • For time >= 17.0 GX11- . Re‐
Sensor 1 Voltage s fer to
(VN) • Diff. pump ⇒ “3.6.41
voltage Oxygen
(VIP) vs. vir‐ Sensor 2
tual ground Before Cat‐
voltage alytic Con‐
(VG) <= verter
1.20 V GX11 ,
Checking”,
• Or page 978 .
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
• Case 2:
• Nernst volt‐
age (VN) >
4.4 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2,35
V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.6 V
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.1
V
• Or
• Pump cur‐
rent >
0.0115 A
U0001 CAN: • Message • Time after igni‐ • 0.5 s • 2 DCY – Check the
High Power‐ no feed‐ tion on 0.5 s terminal re‐
Speed train Bus back • Continu‐ sistance of
CAN Com‐ Reading ous the CAN-
munica‐ Back Bus. Refer
tion Bus Sent to
Message ⇒ “3.6.8
CAN-Bus
Terminal
Resistance,
Checking”,
page 910 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
U0002 COM: • Global time • Time after igni‐ • 0.5 s • 2 DCY – Check the
High Power‐ out receiv‐ tion on 0.5 s terminal re‐
Speed train Bus ing no mes‐ • Continu‐ sistance of
CAN Com‐ Commu‐ sage ous the CAN-
munica‐ nication Bus. Refer
tion Bus Check to
Perform‐ ⇒ “3.6.8
ance CAN-Bus
Terminal
Resistance,
Checking”,
page 910 .
U0101 COM: • Received • Time after igni‐ • 0.5 s • 2 DCY – Check the
Lost Com‐ Trans‐ message tion on 0.5 s terminal re‐
munica‐ mission from TCM, • Continu‐ sistance of
tion with Control no mes‐ ous the CAN-
TCM Module sage Bus be‐
(TCM) tween the
Commu‐ Engine
nication Control
With TCM Module -
J623- and
the Trans‐
mission
Control
Module -
J217- . Re‐
fer to
⇒ “3.6.9
CAN-Bus
Terminal
Resistance,
Powertrain,
Checking”,
page 912 .
U0121 COM: • Received • Time after igni‐ • 0.5 s • 2 DCY – Check the
Lost Com‐ Brake message tion on 0.5 s terminal re‐
munica‐ System from TCS, • Continu‐ sistance of
tion With Control no mes‐ ous the CAN-
Anti-Lock Module sage Bus. Refer
Brake Sys‐ (BSCM) to
tem (ABS) Commu‐ ⇒ “3.6.8
Control nication CAN-Bus
Module With Terminal
BSCM Resistance,
Checking”,
page 910 .
U0140 COM: • Message, • Time after igni‐ • 2.0 s • 2 DCY – Check the
Lost Com‐ Body no mes‐ tion on 0.5 s terminal re‐
munica‐ Control sage • Continu‐ sistance of
tion With Module ous the CAN-
Body Con‐ (BCM) Bus. Refer
trol Mod‐ Commu‐ to
ule nication ⇒ “3.6.8
With CAN-Bus
BCM Terminal
Resistance,
Checking”,
page 910 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
U0141 COM: • Message, • Time after igni‐ • 1.0 s • 2 DCY – Check the
Lost Com‐ Body no mes‐ tion on > 500.0 terminal re‐
munica‐ Control sage ms • Continu‐ sistance of
tion With Module 2 ous the CAN-
Body Con‐ (BCM) Bus. Refer
trol Mod‐ Commu‐ to
ule "A" nication ⇒ “3.6.8
With CAN-Bus
BCM 2 Terminal
Resistance,
Checking”,
page 910 .
U0146 COM: • Message, • Time after igni‐ • 1.0 s • 2 DCY – Check the
Lost Com‐ Gateway no mes‐ tion on 0.5 s terminal re‐
munica‐ Commu‐ sage • Continu‐ sistance of
tion With nication ous the CAN-
Gateway With Bus. Refer
"A" Gateway to
⇒ “3.6.8
CAN-Bus
Terminal
Resistance,
Checking”,
page 910 .
U0155 COM: In‐ • Message, • Time after igni‐ • 0.5 s • 2 DCY – Check the
Lost Com‐ strument no mes‐ tion on 0.5 s terminal re‐
munica‐ Panel sage • Continu‐ sistance of
tion With Cluster ous the CAN-
Instrument (IPC) Bus. Refer
Panel Commu‐ to
Cluster nication ⇒ “3.6.8
(IPC) Con‐ With IPC CAN-Bus
trol Mod‐ Terminal
ule Resistance,
Checking”,
page 910 .
U0199 COM: • Message, • Time after igni‐ • 1.0 s • 2 DCY – Check the
Lost Com‐ Door no mes‐ tion on > 500.0 terminal re‐
munica‐ Control sage ms • Continu‐ sistance of
tion With Module ous the CAN-
"Door Commu‐ Bus. Refer
Control nication to
Module A" With ⇒ “3.6.8
Door CAN-Bus
Control Terminal
Module Resistance,
(Driver- Checking”,
Side) page 910 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
U0302 COM: • Received A/ • Time after igni‐ • 5.0 s • 2 DCY – Check the
Software Trans‐ T vehicle tion on 0.5 s terminal re‐
Incompati‐ mission data from • Continu‐ sistance of
bility With Control TCM signal ous the CAN-
Transmis‐ Module Bus be‐
sion Con‐ (TCM) tween the
trol Mod‐ Commu‐ Transmis‐
ule nication sion Control
With TCM Module -
J217- and
the Engine
Control
Module -
J623- . Re‐
fer to
⇒ “3.6.9
CAN-Bus
Terminal
Resistance,
Powertrain,
Checking”,
page 912 .
U0322 COM: • Ambient • Time after igni‐ • 2.0 s • 2 DCY – Check the
Software Gateway tempera‐ tion on > 0.1 s terminal re‐
Incompati‐ Commu‐ ture sensor • Continu‐ sistance of
bility With nication coding ous the CAN-
Body Con‐ With monitoring Bus. Refer
trol Mod‐ Gateway failure to
ule ⇒ “3.6.8
CAN-Bus
Terminal
Resistance,
Checking”,
page 910 .
U0402 COM: • Received • Time after igni‐ • 0.3 s • 2 DCY – Check the
Invalid Da‐ Trans‐ data from tion on 0.5 s terminal re‐
ta Re‐ mission TCM, im‐ • Continu‐ sistance of
ceived Control plausible ous the CAN-
From TCM Module message Bus be‐
(TCM) tween the
Commu‐ Transmis‐
nication sion Control
With TCM Module -
J217- and
the Engine
Control
Module -
J623- . Re‐
fer to
⇒ “3.6.9
CAN-Bus
Terminal
Resistance,
Powertrain,
Checking”,
page 912 .
U0415 Vehicle • Vehicle • 10.0 s • 2 DCY – Check the
Invalid Da‐ Speed speed > 203 vehicle
ta Re‐ Rationali‐ mph • Continu‐ speed sig‐
ceived ty Check ous nal. Refer to
From Anti- High ⇒ “3.6.47
Lock Vehicle
Brake Sys‐ Speed Sig‐
tem (ABS) nal, Check‐
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
Control COM: • Received • Time after igni‐ • 0.1 s ing”,
Module Brake data from tion on 0.5 s page 992 .
System TCS, im‐ • Continu‐
Control plausible ous
Module message
(BSCM)
Commu‐
nication
With
BSCM
COM: • Speed sen‐ • Time since en‐ • 0.5 s
Vehicle sor signal: gine running >
Speed sensor error 0.5 s • Continu‐
Sensor (no map, ous
(VSS) just bottom
Commu‐ and top lim‐
nication it) = 655,35
With km/h
BSCM
• Speed sen‐ • Time since en‐ • 2.0 s
sor signal: gine running >
initialization 0.5 s • Continu‐
error (no ous
map, just • Vehicle speed <
bottom and 7 mph
top limit) =
655.33 –
655.34 km/
h
U0422 COM: • Ambient • Time after igni‐ • 3.0 s • 2 DCY – Check the
Invalid Da‐ Gateway tempera‐ tion on > 0.1 s terminal re‐
ta Re‐ Commu‐ ture value • Continu‐ sistance of
ceived nication (initializa‐ • Engine running ous the CAN-
From Body With tion) failure Bus. Refer
Control Gateway to
Module ⇒ “3.6.8
CAN-Bus
Terminal
Resistance,
Checking”,
page 910 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time tion agnostic Pro‐
Descrip‐ Threshold Val‐ Conditions Length cedure
tion ue
U0423 COM: In‐ • Received • Time after igni‐ • 3.0 s • 2 DCY – Check the
Invalid Da‐ strument data from tion on 0.5 s terminal re‐
ta Re‐ Panel IPC, im‐ • Continu‐ sistance of
ceived Cluster plausible ous the CAN-
From In‐ (IPC) message Bus. Refer
strument Commu‐ to
Panel nication ⇒ “3.6.8
Cluster With IPC CAN-Bus
Control Terminal
Module Resistance,
Checking”,
page 910 .
U0431 COM: • Received • Time after igni‐ • 0.3 s • 2 DCY – Check the
Invalid Da‐ Body data from tion on > 500.0 terminal re‐
ta Re‐ Control BCM 2 im‐ ms • Continu‐ sistance of
ceived Module 2 plausible ous the CAN-
From Body (BCM) message Bus. Refer
Control Commu‐ to
Module nication ⇒ “3.6.8
"A" With CAN-Bus
BCM 2 Terminal
Resistance,
Checking”,
page 910 .
U0447 COM: • Received • Time after igni‐ • 0.3 s • 2 DCY – Check the
Invalid Da‐ Gateway data from tion on 0.5 s terminal re‐
ta Re‐ Commu‐ Gateway, • Continu‐ sistance of
ceived nication implausible ous the CAN-
From With message Bus. Refer
Gateway Gateway to
"A" ⇒ “3.6.8
CAN-Bus
Terminal
Resistance,
Checking”,
page 910 .
U1103 ECM: • Production • Vehicle speed < • 0.01 s • 1 DCY – Vehicle in
Production Produc‐ mode active 3 mph production
Mode Ac‐ tion Mode • Continu‐ mode. Re‐
tive Function • Max trip mileage ous fer to appro‐
Monitor‐ since initial vehi‐ priate repair
ing: Mode cle start-up < manual for
Change 62.15 miles resolution.
• During ECM Note the
keep alive-time mode can
after ignition off be deacti‐
vated with a
• Engine speed 0 factory scan
RPM tool or will
automati‐
• For hybrid: cally turn off
after vehicle
• Drive motor off accumu‐
lates the
first 100 km
of driving.
P000B Variable • Adjustment • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"B" Cam‐ Valve angle differ‐ perature 15 – (FTP75: Exhaust
shaft Posi‐ Timing ence >= 130° C 700.0) s Camshaft
tion Slow (VVT) Ex‐ 0.75; < Adjustment
Response haust Ac‐ 7.00° CRK • Engine speed • Continu‐ Valve 1 -
Bank 1 tuator 608 – 7,008 ous N318- . Refer
Rationali‐ RPM to
ty Check • Set point ⇒ “3.6.21
change > 14.0° Exhaust
CRK Camshaft
Adjustment
• Camshaft posi‐ Valve 1
tion not @ max. N318 ,
stop position Checking”,
page 936 .
• Dynamic diag‐
nosis timer >=
0.95 – 4.18 s
P000C Variable • Adjustment • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"A" Cam‐ Valve angle differ‐ perature 15 – (FTP75: Camshaft
shaft Posi‐ Timing ence >= 130° C 300.0) s Adjustment
tion Slow (VVT) In‐ 0.75; < Valve 2 -
Response take Ac‐ 7.00° CRK • Engine speed • Continu‐ N208- . Refer
Bank 2 tuator 2 608 – 7,008 ous to
Rationali‐ RPM ⇒ “3.6.3
ty Check • Set point Camshaft
change > 14.0° Adjustment
CRK Valve 2
N208 ,
• Camshaft posi‐ Checking”,
tion not @ max. page 899 .
stop position
• Dynamic diag‐
nosis timer >=
0.95 – 4.18 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P000D Variable • Adjustment • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"B" Cam‐ Valve angle differ‐ perature 15 – (FTP75: Exhaust
shaft Posi‐ Timing ence >= 130° C 700.0) s Camshaft
tion Slow (VVT) Ex‐ 0.75; < Adjustment
Response haust Ac‐ 7.00° CRK • Engine speed • Continu‐ Valve 2 -
Bank 2 tuator 2 608 – 7,008 ous N319- . Refer
Rationali‐ RPM to
ty Check • Set point ⇒ “3.6.22
change > 14.0° Exhaust
CRK Camshaft
Adjustment
• Camshaft posi‐ Valve 2
tion not @ max. N319 ,
stop position Checking”,
page 938 .
• Dynamic diag‐
nosis timer >=
0.95 – 4.18 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0010 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2s • 2 DCY – Check the
"A" Cam‐ tuator In‐ age lower tor solenoid Camshaft
shaft Posi‐ take range 1.92 valve comman‐ • Continu‐ Adjustment
tion Actua‐ Open Cir‐ – 2.21 V ded off ous Valve 1 -
tor Control cuit N205- . Refer
Circuit/ • Output volt‐ to
Open age upper ⇒ “3.6.2
Bank 1 range Camshaft
(hardware Adjustment
values) Valve 1
2.85 – 3.25 N205 ,
V Checking”,
page 897 .
P0011 Variable • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"A" Cam‐ Valve position de‐ perature 15 – (FTP75: Camshaft
shaft Posi‐ Timing viation > 130° C 1,000.0) s Adjustment
tion - Tim‐ (VVT) In‐ 10.0° CRK Valve 1 -
ing Over- take Ac‐ • Engine speed • Continu‐ N205- . Refer
Advanced tuator 608 – 7,008 ous to
or System Rationali‐ RPM ⇒ “3.6.2
Perform‐ ty Check • Camshaft posi‐ Camshaft
ance Bank tion not @ max. Adjustment
1 stop position Valve 1
N205 ,
• Camshaft posi‐ Checking”,
tion adjustment page 897 .
active
• Catalyst heating
not active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 9.0°
CRK times s
P0013 Variable • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ Valve age lower tor solenoid Exhaust
shaft Posi‐ Timing range 1.92 valve comman‐ • Continu‐ Camshaft
tion Actua‐ (VVT) Ex‐ – 2.21 V ded off ous Adjustment
tor Control haust Ac‐ Valve 1 -
Circuit/ tuator • Output volt‐ N318- . Refer
Open Open Cir‐ age upper to
Bank 1 cuit range ⇒ “3.6.21
(hardware Exhaust
values) Camshaft
2.85 – 3.25 Adjustment
V Valve 1
N318 ,
Checking”,
page 936 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0014 Variable • Difference • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"B" Cam‐ Valve between perature 15 – (FTP75: Exhaust
shaft Posi‐ Timing target and 130° C 600.0) s Camshaft
tion - Tim‐ (VVT) Ex‐ actual posi‐ Adjustment
ing Over- haust Ac‐ tion > 10.0° • Engine speed • Continu‐ Valve 1 -
Advanced tuator CRK 608 – 7,008 ous N318- . Refer
or System Rationali‐ RPM to
Perform‐ ty Check • Camshaft posi‐ ⇒ “3.6.21
ance Bank tion not close to Exhaust
1 max. stop posi‐ Camshaft
tion Adjustment
Valve 1
• Camshaft posi‐ N318 ,
tion adaptation Checking”,
active page 936 .
• Catalyst heating
not active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 9.0°
CRK times s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0016 Camshaft • Adapted • camshaft posi‐ • 720.0° • 2 DCY – Check the
Crank‐ Position / value for tion adaptation CRK Camshaft
shaft Posi‐ Crank‐ each edge active (exhaust Adjustment
tion - Cam‐ shaft Po‐ of the target side) • Multiple Valve 1 -
shaft Posi‐ sition wheel < N205- . Refer
tion Corre‐ (CMP/ -19.0° CRK • Engine speed to
lation CKP) In‐ 288 – 8,000 ⇒ “3.6.2
Bank 1 take Sen‐ • Or RPM Camshaft
Sensor A sor adap‐ • Adapted • Modeled oil tem‐ Adjustment
tation value for perature >= -40° Valve 1
Value each edge C N205 ,
Monitor‐ of the target Checking”,
ing wheel > • Modeled oil tem‐ page 897 .
19.0° CRK perature <= 130
– 160° C
• Diff. actual ex‐
haust camshaft
position vs. pre‐
vious camshaft
position @ refer‐
ence signal
edge < 2.0° CRK
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0017 Camshaft • Adapted • camshaft posi‐ • 720.0° • 2 DCY – Check the
Crank‐ Position / value for tion adaptation CRK Exhaust
shaft Posi‐ Crank‐ each edge active (exhaust Camshaft
tion - Cam‐ shaft Po‐ of the target side) • Multiple Adjustment
shaft Posi‐ sition wheel < Valve 1 -
tion Corre‐ (CMP/ -19.0° CRK • Engine speed N318- . Refer
lation CKP) Ex‐ 288 – 8,000 to
Bank 1 haust • Or RPM ⇒ “3.6.21
Sensor B Sensor • Adapted • Modeled oil tem‐ Exhaust
Adapta‐ value for perature >= -40° Camshaft
tion Val‐ each edge C Adjustment
ue Moni‐ of the target Valve 1
toring wheel > • Modeled oil tem‐ N318 ,
19.0° CRK perature <= 130 Checking”,
– 160° C page 936 .
• Diff. actual ex‐
haust camshaft
position vs. pre‐
vious camshaft
position @ refer‐
ence signal
edge < 2.0° CRK
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0018 Camshaft • Adapted • camshaft posi‐ • 720.0° • 2 DCY – Check the
Crank‐ Position value for tion adaptation CRK Camshaft
shaft Posi‐ 2/ Crank‐ each edge active (exhaust Adjustment
tion - Cam‐ shaft Po‐ of the target side) • Multiple Valve 2 -
shaft Posi‐ sition wheel < N208- . Refer
tion Corre‐ (CMP/ -19.0° CRK • Engine speed to
lation CKP) In‐ 288 – 8,000 ⇒ “3.6.3
Bank 2 take Sen‐ • Or RPM Camshaft
Sensor A sor Adap‐ • Adapted • Modeled oil tem‐ Adjustment
tation value for perature >= -40° Valve 2
Value each edge C N208 ,
Monitor‐ of the target Checking”,
ing wheel > • Modeled oil tem‐ page 899 .
19.0° CRK perature <= 130
– 160° C
• Diff. actual ex‐
haust camshaft
position vs. pre‐
vious camshaft
position @ refer‐
ence signal
edge < 2.0° CRK
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0019 Camshaft • Adapted • camshaft posi‐ • 720.0° • 2 DCY – Check the
Crank‐ Position value for tion adaptation CRK Exhaust
shaft Posi‐ 2/ Crank‐ each edge active (exhaust Camshaft
tion - Cam‐ shaft Po‐ of the target side) • Multiple Adjustment
shaft Posi‐ sition wheel < Valve 2 -
tion Corre‐ (CMP/ -19.0° CRK • Engine speed N319- . Refer
lation CKP) Ex‐ 288 – 8,000 to
Bank 2 haust • Or RPM ⇒ “3.6.22
Sensor B Sensor • Adapted • Modeled oil tem‐ Exhaust
Adapta‐ value for perature >= -40° Camshaft
tion Val‐ each edge C Adjustment
ue Moni‐ of the target Valve 2
toring wheel > • Modeled oil tem‐ N319 ,
19.0° CRK perature <= 130 Checking”,
– 160° C page 938 .
• Diff. actual ex‐
haust camshaft
position vs. pre‐
vious camshaft
position @ refer‐
ence signal
edge < 2.0° CRK
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0020 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"A" Cam‐ tuator In‐ age, lower tor solenoid Camshaft
shaft Posi‐ take range 1.92 valve comman‐ • Continu‐ Adjustment
tion Actua‐ Bank 2 – 2.21 V ded off ous Valve 2 -
tor Control Open Cir‐ N208- . Refer
Circuit/ cuit • Output volt‐ to
Open age, upper ⇒ “3.6.3
Bank 2 range Camshaft
(hardware Adjustment
values) Valve 2
2.85 – 3.25 N208 ,
V Checking”,
page 899 .
P0021 VVT Ac‐ • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"A" Cam‐ tuator In‐ position de‐ perature 15 – (FTP75: Camshaft
shaft Posi‐ take viation > 130° C 1,000.0) s Adjustment
tion - Tim‐ Bank 2 10.0° CRK Valve 2 -
ing Over- Rationali‐ • Engine speed • Continu‐ N208- . Refer
Advanced ty Check 608 – 7,008 ous to
or System RPM ⇒ “3.6.3
Perform‐ • Camshaft posi‐ Camshaft
ance Bank tion not @ max. Adjustment
2 stop position Valve 2
N208 ,
• Camshaft posi‐ Checking”,
tion adaptation page 899 .
active
• Catalyst heating
not active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 9.0°
CRK times s
P0023 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator age, lower tor solenoid Exhaust
shaft Posi‐ Outlet range 1.92 valve comman‐ • Continu‐ Camshaft
tion Actua‐ Bank 2 – 2.21 V ded off ous Adjustment
tor Control Open Cir‐ Valve 2 -
Circuit/ cuit • Output volt‐ N319- . Refer
Open age, upper to
Bank 2 range ⇒ “3.6.22
(hardware Exhaust
values) Camshaft
2.85 – 3.25 Adjustment
V Valve 2
N319 ,
Checking”,
page 938 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0024 VVT Ac‐ • Difference • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
"B" Cam‐ tuator between perature 15 – (FTP75: Exhaust
shaft Posi‐ Outlet target and 130° C 600.0) s Camshaft
tion - Tim‐ Bank 2 actual posi‐ Adjustment
ing Over- Rationali‐ tion > 10.0° • Engine speed • Continu‐ Valve 2 -
Advanced ty Check CRK 608 – 7,008 ous N319- . Refer
or System RPM to
Perform‐ • Camshaft posi‐ ⇒ “3.6.22
ance Bank tion not close to Exhaust
2 max. stop posi‐ Camshaft
tion Adjustment
Valve 2
• Camshaft posi‐ N319 ,
tion adaptation Checking”,
active page 938 .
• Catalyst heating
not active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 9.0°
CRK times s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0032 Oxygen • O2S up‐ • Modeled EGT @ • 2.5 s • 2 DCY – Check the
HO2S Sensors stream O2S front >= Oxygen Sen‐
Heater Heater heater driv‐ -273° C • Continu‐ sor 1 Before
Control Front er tempera‐ ous Catalytic
Circuit Short To ture > 160.0 • Actuator com‐ Converter -
High Bank Battery – 200.0° C manded on GX10- . Re‐
1 Sensor 1 Plus fer to
• Or ⇒ “3.6.39
• O2S up‐ Oxygen Sen‐
stream sor 1 Before
heater driv‐ Catalytic
er output Converter
current driv‐ GX10 ,
er stage in‐ Checking”,
ternal value page 972 .
P0036 Oxygen • O2S down‐ • Engine not in • 2.5 s • 2 DCY – Check the
HO2S Sensors stream start process Oxygen Sen‐
Heater Heater heater volt‐ • Continu‐ sor 1 After
Control Rear age, lower ous Catalytic
Circuit Open Cir‐ range 1.92 Converter -
Bank 1 cuit – 2.21 V GX7- . Refer
Sensor 2 to
• O2S down‐ ⇒ “3.6.38
stream Oxygen Sen‐
heater volt‐ sor 1 After
age, upper Catalytic
range 2.85 Converter
– 3.25 V GX7 , Check‐
ing”,
page 970 .
P0037 Oxygen • O2S down‐ • Engine not in • 2.5 s • 2 DCY – Check the
HO2S Sensors stream start process Oxygen Sen‐
Heater Heater heater volt‐ • Continu‐ sor 1 After
Control Rear age < 1.92 – ous Catalytic
Circuit Short To 2.21 V Converter -
Low Bank Ground GX7- . Refer
1 Sensor 2 to
⇒ “3.6.38
Oxygen Sen‐
sor 1 After
Catalytic
Converter
GX7 , Check‐
ing”,
page 970 .
P0038 Oxygen • O2S down‐ • Modeled EGT @ • 2.5 s • 2 DCY – Check the
HO2S Sensors stream O2S rear >= Oxygen Sen‐
Heater Heater heater driv‐ -273° C • Continu‐ sor 1 After
Control Rear er tempera‐ ous Catalytic
Circuit Short To ture > 160.0 • Heater com‐ Converter -
High Bank Battery – 200.0° C manded on GX7- . Refer
1 Sensor 2 Plus • Engine not in to
• Or ⇒ “3.6.38
start process
• O2S down‐ Oxygen Sen‐
stream sor 1 After
heater driv‐ Catalytic
er output Converter
current driv‐ GX7 , Check‐
er stage in‐ ing”,
ternal value page 970 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0050 Oxygen • O2S up‐ • 2.5 s • 2 DCY – Check the
HO2S Sensors stream Oxygen Sen‐
Heater Heater heater volt‐ • Continu‐ sor 2 Before
Control Front age, lower ous Catalytic
Circuit Bank 2 range 1.92 Converter -
Bank 2 Open Cir‐ – 2.21 V GX11- . Re‐
Sensor 1 cuit fer to
• O2S up‐ ⇒ “3.6.41
stream Oxygen Sen‐
heater volt‐ sor 2 Before
age, upper Catalytic
range 2.85 Converter
– 3.25 V GX11 ,
Checking”,
page 978 .
P0051 Oxygen • O2S up‐ • 2.5 s • 2 DCY – Check the
HO2S Sensors stream Oxygen Sen‐
Heater Heater heater volt‐ • Continu‐ sor 2 Before
Control Front age < 1.92 – ous Catalytic
Circuit Bank 2 2.21 V Converter -
Low Bank Short To GX11- . Re‐
2 Sensor 1 Ground fer to
⇒ “3.6.41
Oxygen Sen‐
sor 2 Before
Catalytic
Converter
GX11 ,
Checking”,
page 978 .
P0052 Oxygen • O2S up‐ • Modeled EGT @ • 2.5 s • 2 DCY – Check the
HO2S Sensors stream O2S front >= Oxygen Sen‐
Heater Heater heater driv‐ -273° C • Continu‐ sor 2 Before
Control Front er tempera‐ ous Catalytic
Circuit Bank 2 ture > 160.0 • Actuator com‐ Converter -
High Bank Short To – 200.0° C manded on GX11- . Re‐
2 Sensor 1 Battery fer to
Plus • Or ⇒ “3.6.41
• O2S up‐ Oxygen Sen‐
stream sor 2 Before
heater driv‐ Catalytic
er output Converter
current driv‐ GX11 ,
er stage in‐ Checking”,
ternal value page 978 .
P0056 Oxygen • O2S down‐ • Engine not in • 2.5 s • 2 DCY – Check the
HO2S Sensors stream start process Oxygen Sen‐
Heater Heater heater volt‐ • Continu‐ sor 2 After
Control Rear age, lower ous Catalytic
Circuit Bank 2 range 1.92 Converter -
Bank 2 Open Cir‐ – 2.21 V GX8- . Refer
Sensor 2 cuit to
• O2S down‐ ⇒ “3.6.40
stream Oxygen Sen‐
heater volt‐ sor 2 After
age, upper Catalytic
range 2.85 Converter
– 3.25 V GX8 , Check‐
ing”,
page 976 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0057 Oxygen • O2S down‐ • Engine not in • 2.5 s • 2 DCY – Check the
HO2S Sensors stream start process Oxygen Sen‐
Heater Heater heater volt‐ • Continu‐ sor 2 After
Control Rear age < 1.92 – ous Catalytic
Circuit Bank 2 2.21 V Converter -
Low Bank Short To GX8- . Refer
2 Sensor 2 Ground to
⇒ “3.6.40
Oxygen Sen‐
sor 2 After
Catalytic
Converter
GX8 , Check‐
ing”,
page 976 .
P0058 Oxygen • O2S down‐ • Modeled EGT @ • 2.5 s • 2 DCY – Check the
HO2S Sensors stream O2S front >= Oxygen Sen‐
Heater Heater heater driv‐ -273° C • Continu‐ sor 2 After
Control Rear er tempera‐ ous Catalytic
Circuit Bank 2 ture > 160.0 • Heater com‐ Converter -
High Bank Short To – 200.0° C manded on GX8- . Refer
2 Sensor 2 Battery • Engine not in to
Plus • Or ⇒ “3.6.40
start process
• O2S down‐ Oxygen Sen‐
stream sor 2 After
heater driv‐ Catalytic
er output Converter
current > GX8 , Check‐
8.0 – 12.0 A ing”,
page 976 .
P006C Manifold • Manifold • 0.5 s • 2 DCY – Check the In‐
MAP - Tur‐ Absolute pressure take Air Tem‐
bocharger/ Pressure sensor sig‐ • Continu‐ perature
Super‐ (MAP) nal failure ous Sensor -
charger In‐ Sensor 1 detected G42- / Mani‐
let Pres‐ and 2 fold Absolute
sure Cor‐ commu‐ • Manifold Pressure
relation nication pressure Sensor -
check sensor 2 G71- . Refer
signal fail‐ to
ure detec‐ ⇒ “3.6.30 In‐
ted take Air Tem‐
perature
Sensor G42 /
Manifold Ab‐
solute Pres‐
sure Sensor
G71 , Check‐
ing”,
page 954 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0070 CAN: • AAT sensor • 2.0 s • 2 DCY – Check the In‐
Ambient Ambient voltage take Air Tem‐
Air Tem‐ Air Tem‐ (hardware • Continu‐ perature
perature perature values) > ous Sensor -
Sensor Sensor 4.50 V G42- / Mani‐
Circuit "A" Short To fold Absolute
Battery / Pressure
Open Cir‐ Sensor -
cuit G71- . Refer
to
⇒ “3.6.30 In‐
take Air Tem‐
perature
Sensor G42 /
Manifold Ab‐
solute Pres‐
sure Sensor
G71 , Check‐
ing”,
page 954 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0071 Ambient • High side: • Engine off time • 0.1 s • 2 DCY – Check the In‐
Ambient Air Tem‐ reference monitoring >= take Air Tem‐
Air Tem‐ perature measuring 360.0 min • Once / perature
perature Sensor DCY Sensor -
Sensor Cross • Diff. AAT @ • Engine off time G42- / Mani‐
Circuit "A" Check cold start monitoring fin‐ fold Absolute
Range/ vs. IAT @ ished Pressure
Perform‐ manifold @ Sensor -
ance cold start > • Time after en‐
G71- . Refer
25.0 K gine start <=
450.0 s to
• Diff. AAT @ ⇒ “3.6.30 In‐
cold start • Time after ECM take Air Tem‐
vs. IAT @ wake up 1.5 – perature
manifold 2 900.0 s Sensor G42 /
@ cold start • Manifold Ab‐
AAT sensor sig‐ solute Pres‐
> 25.0 K nal valid sure Sensor
• Diff. AAT @ • G71 , Check‐
Depending on
cold start ing”,
temperature
vs. ECT @ page 954 .
slope @ cold
cylinder start:
block @
cold start > • Diff. actual vs.
25.0 K previous IAT
downstream
• Diff. AAT @ throttle @ cold
cold start start < 0.8 K
vs. IAT
down‐ • Diff. actual vs.
stream previous IAT @
throttle @ manifold @ cold
cold start > start < 0.8 K
25.0 K
• Diff. actual vs.
• Min. previous IAT @
amount of manifold 2 @
faulty refer‐ cold start < 0.8 K
ence meas‐
urements to • Diff. actual vs.
detect de‐ previous ECT @
fective sen‐ cylinder block @
sor 4.00 [-] cold start < 0.8 K
• Or • Diff. actual vs.
previous AAT @
• Low side: cold start < 0.8 K
reference
measuring • For time >= 1.0 s
• Diff. IAT @ • Depending on
manifold @ mean value con‐
cold start dition
vs. AAT @ • Mean value of all
cold start > temperature
25.0 K sensors @ cold
• Diff. IAT @ start >= -256° C
manifold 2 • Number of valid
@ cold start sensors >= 4.00
vs. AAT @ [-]
cold start >
25.0 K • Depending on
block heater /
solar radiation
detection
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. ECT @ • Time after en‐
cylinder gine start >=
block @ 410.5 s
cold start
vs. AAT @ • Vehicle speed
cold start > >= 22 mph
25.0 K • For time >=
• diff. IAT 410.0 s
down‐ • Diff. actual IAT
stream @ downstream
throttle @ throttle vs. min.
cold start IAT @ down‐
vs. AAT @ stream throttle <
cold start > 4.0 K
25.0 K
• Diff. actual IAT
• Min. @ manifold vs.
amount of min. IAT @
faulty refer‐ manifold < 4.0 K
ence meas‐
urements to • Diff. actual IAT
detect de‐ @ manifold 2 vs.
fective sen‐ min. IAT @
sor 4.0 [-] manifold 2 < 4.0
K
• Diff. actual ECT
@ cylinder block
vs. min. ECT @
cylinder block <
4.0 K
• Diff. actual AAT
vs. min. AAT <
4.0 K
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P007B IAT Sen‐ • IAT sensor • 0.5 s • 2 DCY – Check the
Charge Air sor @ failure Charge Air
Cooler Manifold • Continu‐ Pressure
Tempera‐ Sensor ous Sensor -
ture Sen‐ Internal G31- / Intake
sor Circuit Fault Manifold
Range/ Temperature
Perform‐ Sensor -
ance Bank G72- . Refer
1 to
⇒ “3.6.10
Charge Air
Pressure
Sensor G31 /
Intake Mani‐
fold Temper‐
ature Sensor
G72 , Check‐
ing”,
page 914 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0087 Fuel Sys‐ • Deviation • Engine speed • 2.0 s • 2 DCY – Check the
Fuel Rail/ tem Pres‐ between 512 – 8,160 Fuel Pres‐
System sure Sen‐ reference RPM • Continu‐ sure Sensor -
Pressure - sor, High fuel pres‐ ous G247- . Re‐
Too Low Pressure sure set • Mass fuel flow fer to
Bank 1 Side Out point and set point 5.0 – ⇒ “3.6.27
Of Range current fuel 1,389.0 mg/rev Fuel Pres‐
Low pressure > • Time after en‐ sure Sensor
2,000.10 gine start > 25.0 G247 ,
kPa s Checking”,
page 948 .
• Case: 1 • Engine warm-up
• deviation not active – Check the
lambda of • Fuel Meter‐
Catalyst heating ing Valve -
controller n.a.
included N290- . Refer
adaption to
• Full load n.a.
17.0 – 50.0 ⇒ “3.6.26
% • Catalyst purge Fuel Meter‐
not active ing Valve
• High pres‐ N290 ,
sure con‐ • Lambda control Checking”,
troller out‐ n.a. page 946 .
put > 25 mg • Evap purge
• Fuel pres‐ functionality di‐
sure < agnosis not ac‐
34,777.60 tive
kPa • And
• Case: 2 • Depending on
• Fuel pump low dynamic
at max limit conditions:
• Mass fuel • Fuel mass set‐
flow set point lower
point < range > 0.00
1,389.0 mg/ mg/rev
rev • For time >= 2.0 s
• Fuel pres‐ • Fuel mass set‐
sure < point upper
1,500.21 range < 54.41 –
kPa 290.98 mg/rev
• Diff. fuel mass
setpoint vs. fil‐
tered fuel mass
setpoint <= 2.50
mg/rev
• For time >= 3.0 s
• And depending
on canister
purge:
• Canister load <=
2.00 [-]
• Or
• Evap purge
valve not active
or closed
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Deviation • Engine speed • 5.0 s
tem, High lambda of 512 – 8,160
Pressure controller RPM • Continu‐
Side Ra‐ included ous
tionality adaption • Mass fuel flow
Check -15.0 – 15.0 set point 5.0 –
Low % 1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge
valve not active
or closed
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0088 Fuel Rail • Deviation • General: • 5.0 s • 2 DCY – Check the
Fuel Rail/ Pressure between Fuel Pres‐
System (FRP) out fuel pres‐ • Engine speed • Continu‐ sure Sensor -
Pressure - of range sure set‐ 512 – 8160 rpm ous G247- . Re‐
Too High high point and • Fuel mass set‐ fer to
Bank 1 current fuel point 5.00 – ⇒ “3.6.27
pressure < 1389.00 mg/rev Fuel Pres‐
-2999.90 sure Sensor
kPa • Time after en‐ G247 ,
gine start > 25.0 Checking”,
• Deviation [s] page 948 .
lambda of
controller • Engine warm-up – Check the
included not active Fuel Meter‐
adaption ing Valve -
-12.50 – • Catalyst heating N290- . Refer
12.50 % not calibrated to
• Case 1: • Full load not cali‐ ⇒ “3.6.26
brated Fuel Meter‐
• High pres‐ ing Valve
sure con‐ • Catalyst purge N290 ,
troller out‐ not active Checking”,
put < -48 page 946 .
• Lambda control
mg not calibrated
• Case 2: • Evap purge
• Flow control functionality di‐
valve open agnosis not ac‐
tive
• Mass fuel
flow set‐ • And
point > 6.51 • Depending on
mg/rev low dynamic
conditions:
• Fuel mass set‐
point lower
range > 0.00
mg/rev
• For time >= 2.0 s
• Fuel mass set‐
point upper
range < 54.41 –
290.98 mg/rev
• Diff.fuel mass
setpoint vs. fil‐
tered fuel mass
setpoint <= 2.50
mg/rev
• For time >= 3.0 s
• And
• Depending on
canister purge:
• Canister load <=
2.00 [-]
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge
valve not active
or closed
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel • Case 1: • Engine warm-up
Pump not active
Out Of • Actual and
Range adapted I- • Catalyst heating
Low part of elec‐ not active
tric fuel
pump con‐ • Engine no full
troller load
(PWM sig‐ • Lambda control
nal) > 25.0 active
%
• Catalyst over‐
• For time >= heating protec‐
20.0 s tion not active
• Or • Catalyst purge
• Case 2: not active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Of Range the pressure
Low sensor. Re‐
fer to Fuel
System Me‐
chanical
Testing in
⇒ “3.1 Pre‐
liminary
Check”,
page 20 .
– Check the
Low Fuel
Pressure
Sensor -
G410- . Re‐
fer to
⇒ “3.6.36
Low Fuel
Pressure
Sensor
G410 ,
Checking”,
page 965 .
– Check the
Low Fuel
Pressure
Sensor -
G410- . Re‐
fer to
⇒ “3.6.36
Low Fuel
Pressure
Sensor
G410 ,
Checking”,
page 965 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0090 Fuel Con‐ • Voltage • Engine speed 0 • 0.8 s • 2 DCY – Check the
Fuel Pres‐ trol Valve high side < RPM Fuel Pres‐
sure Reg‐ Open Cir‐ 1.87 – 2.26 • Continu‐ sure Sensor -
ulator 1 cuit V • Or ous G247- . Re‐
Control fer to
Circuit/ • Voltage low • Fuel cut off ac‐
⇒ “3.6.27
side > 2.78 tive
Open Fuel Pres‐
– 3.33 V • Actuator com‐ sure Sensor
manded off G247 ,
Checking”,
• Low and • Engine speed > page 948 .
high side 600 RPM
off:
• And
• Voltage low
side > 2.78 • Fuel cut off not
– 3.33 V active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0092 Fuel Con‐ • Current low • Ignition on • 0.1 s • 2 DCY – Check the
Fuel Pres‐ trol Valve side (hard‐ Fuel Pres‐
sure Reg‐ Short To ware val‐ • Or • Continu‐ sure Sensor -
ulator 1 Battery ues) driver • ous G247- . Re‐
Ignition off (dur‐
Control Plus (Low stage inter‐ ing ECM keep fer to
Circuit Side) nal value alive-time) ⇒ “3.6.27
High Fuel Pres‐
• And sure Sensor
G247 ,
• Actuator com‐ Checking”,
manded on page 948 .
Fuel Con‐ • Voltage • Ignition on
trol Valve high side
Short To (hardware • Or
Battery values) < • Ignition off (dur‐
Plus 1.92 – 2.21 ing ECM keep
(High V alive-time)
Side)
• And
• Actuator com‐
manded off
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0096 Intake Air • High side: • Engine off time • 0.1 s • 2 DCY – Check the In‐
Intake Air Tempera‐ reference >= 360.0 min take Air Tem‐
Tempera‐ ture Sen‐ measuring • Once / perature
ture Too sor • Engine off time DCY Sensor -
High Down‐ • Diff. IAT monitoring fin‐ G42- / Mani‐
stream down‐ ished fold Absolute
Throttle stream Pressure
Cross throttle @ • Time after en‐
Sensor -
cold start gine start <=
Check 450.0 s G71- . Refer
vs. IAT @ to
manifold @ • Time after ECM ⇒ “3.6.30 In‐
cold start > wake up 1.5 – take Air Tem‐
25.0 K 900.0 s perature
• Diff. IAT Sensor G42 /
• AAT sensor sig‐ Manifold Ab‐
down‐ nal valid
stream solute Pres‐
throttle @ • sure Sensor
Depending on
cold start G71 , Check‐
temperature
vs. IAT @ ing”,
slope @ cold
manifold 2 page 954 .
start:
@ cold start
> 25.0 K • Diff. actual vs.
previous IAT
• Diff. IAT downstream
down‐ throttle @ cold
stream start < 0.8 K
throttle @
cold start • Diff. actual vs.
vs. ECT @ previous IAT @
cylinder manifold @ cold
block @ start < 0.8 K
cold start > • Diff. actual vs.
25.0 K previous IAT @
• Diff. IAT manifold 2 @
down‐ cold start < 0.8 K
stream
throttle @ • Diff. actual vs.
previous ECT @
cold start cylinder block @
vs. AAT @ cold start < 0.8 K
cold start >
25.0 K • Diff. actual vs.
previous AAT @
• Min. cold start < 0.8 K
amount of
faulty refer‐ • For time >= 1.0 s
ence meas‐
urements to • Depending on
detect de‐ mean value con‐
fective sen‐ dition
sor 4.0 [-]
• Mean value of all
• Or temperature
sensors @ cold
• Low side: start >= -256° C
reference
measuring • Number of valid
sensors >= 4.00
[-]
• Depending on
block heater /
solar radiation
detection
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. IAT @ • Time after en‐
manifold @ gine start >=
cold start 410.5 s
vs. IAT
down‐ • Vehicle speed
stream >= 22 mph
throttle @ • For time >= 20.0
cold start > s
25.0 K
• Diff. actual IAT
• Diff. IAT @ @ downstream
manifold 2 throttle vs. min.
@ cold start IAT @ down‐
vs. IAT stream throttle <
down‐ 4.0 K
stream
throttle @ • Diff. actual IAT
cold start > @ manifold vs.
25.0 K min. IAT @
manifold < 4.0 K
• Diff. ECT @
cylinder • Diff. actual IAT
block @ @ manifold 2 vs.
cold start min. IAT @
vs. IAT manifold 2 < 4.0
down‐ K
stream
throttle @ • Diff. actual ECT
cold start > @ cylinder block
25.0 K vs. min. ECT @
cylinder block <
• Diff. AAT @ 4.0 K
cold start
vs. IAT • Diff. actual AAT
down‐ vs. min. AAT <
stream 4.0 K
throttle @
cold start >
25.0 K
• Min.
amount of
faulty refer‐
ence meas‐
urements to
detect de‐
fective sen‐
sor 4.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P00A1 IAT Sen‐ • IAT sensor • 0.5 s • 2 DCY – Check the
Charge Air sor @ failure Charge Air
Cooler Manifold • Continu‐ Pressure
Tempera‐ 2 Sensor ous Sensor 2 -
ture Sen‐ Internal G447- / In‐
sor Circuit Fault take Mani‐
Range/ fold Temper‐
Perform‐ ature Sensor
ance Bank 2 - G430- .
2 Refer to
⇒ “3.6.11 In‐
take Mani‐
fold Temper‐
ature Sensor
2 G430 /
Charge Air
Pressure
Sensor 2
G447 ,
Checking”,
page 916 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P00AB Intake Air • High side: • Engine off time • 0.1 s • 2 DCY – Check the
Intake Air Tempera‐ reference >= 360.0 min Charge Air
Tempera‐ ture (IAT) measuring • Once / Pressure
ture Sen‐ Sensor • Engine off time DCY Sensor 2 -
sor 1 Cir‐ @ Mani‐ • Diff. IAT @ monitoring fin‐ G447- / In‐
cuit fold 2 manifold 2 ished take Mani‐
Range/ Cross @ cold start fold Temper‐
Perform‐ Check vs. IAT @ • Time after en‐
ature Sensor
manifold @ gine start <=
ance Bank 450.0 s 2 - G430- .
2 cold start > Refer to
25.0 K • Time after ECM ⇒ “3.6.11 In‐
• Diff. IAT @ wake up 1.5 – take Mani‐
manifold 2 900.0 s fold Temper‐
@ cold start • ature Sensor
AAT sensor sig‐ 2 G430 /
vs. IAT nal valid
down‐ Charge Air
stream Pressure
• Depending on
throttle @ Sensor 2
temperature
cold start > G447 ,
slope @ cold
25.0 K Checking”,
start: page 916 .
• Diff. IAT @ • Diff. actual vs.
manifold 2 previous IAT
@ cold start downstream
vs. ECT @ throttle @ cold
cylinder start < 0.8 K
block @
cold start > • Diff. actual vs.
25.0 K previous IAT @
manifold @ cold
• Diff. IAT @ start < 0.8 K
manifold 2
@ cold start • Diff. actual vs.
vs. AAT @ previous IAT @
cold start > manifold 2 @
25.0 K cold start < 0.8 K
• Min. • Diff. actual vs.
amount of previous ECT @
faulty refer‐ cylinder block @
ence meas‐ cold start < 0.8 K
urements to • Diff. actual vs.
detect de‐ previous AAT @
fective sen‐ cold start < 0.8 K
sor 4.0 [-]
• For time >= 1.0 s
• Or
• Depending on
• Low side: mean value con‐
reference dition
measuring
Diff. IAT @ • Mean value of all
• temperature
manifold @ sensors @ cold
cold start start >= -256° C
vs. IAT @
manifold 2 • Number of valid
@ cold start sensors >= 4.00
> 25.0 K [-]
• Depending on
block heater /
solar radiation
detection
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. IAT • Time after en‐
down‐ gine start >=
stream 410.5 s
throttle @
cold start • Vehicle speed
vs. IAT @ >= 22 mph
manifold 2 • For time >= 20.0
@ cold start s
> 25.0 K
• Diff. actual IAT
• Diff. ECT @ @ downstream
cylinder throttle vs. min.
block @ IAT @ down‐
cold start stream throttle <
vs. IAT @ 4.0 K
manifold 2
@ cold start • Diff. actual IAT
> 25.0 K @ manifold vs.
min. IAT @
• Diff. AAT @ manifold < 4.0 K
cold start
vs. IAT @ • Diff. actual IAT
manifold 2 @ manifold 2 vs.
@ cold start min. IAT @
> 25.0 K manifold 2 < 4.0
K
• Min.
amount of • Diff. actual ECT
faulty refer‐ @ cylinder block
ence meas‐ vs. min. ECT @
urements to cylinder block <
detect de‐ 4.0 K
fective sen‐
sor 4.0 [-] • Diff. actual AAT
vs. min. AAT <
4.0 K
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0108 Pressure • Signal volt‐ • 0.5 s • 2 DCY – Check the In‐
Manifold Sensor age > 4.80 take Air Tem‐
Absolute Down‐ V • Continu‐ perature
Pressure/ stream ous Sensor -
Baromet‐ Throttle G42- / Mani‐
ric Pres‐ Short To fold Absolute
sure Sen‐ Battery Pressure
sor Circuit Plus / Sensor -
High open cir‐ G71- . Refer
cuit to
⇒ “3.6.30 In‐
take Air Tem‐
perature
Sensor G42 /
Manifold Ab‐
solute Pres‐
sure Sensor
G71 , Check‐
ing”,
page 954 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0111 IAT Sen‐ • High side: • Engine off time • 0.1 s • 2 DCY – Check the In‐
Intake Air sor @ reference >= 360.0 min take Air Tem‐
Tempera‐ Manifold measuring • Once / perature
ture Sen‐ Cross • Engine off time DCY Sensor -
sor 1 Cir‐ Check • Diff. IAT @ monitoring fin‐ G42- / Mani‐
cuit manifold 2 ished fold Absolute
Range/ @ cold start Pressure
Perform‐ vs. IAT @ • Time after en‐
Sensor -
manifold @ gine start <=
ance Bank 450.0 s G71- . Refer
1 cold start > to
25.0 K • Time after ECM ⇒ “3.6.30 In‐
• Diff. IAT @ wake up 1.5 – take Air Tem‐
manifold 2 900.0 s perature
@ cold start • Sensor G42 /
AAT sensor sig‐ Manifold Ab‐
vs. IAT nal valid
down‐ solute Pres‐
stream sure Sensor
• Depending on
throttle @ G71 , Check‐
temperature
cold start > ing”,
slope @ cold
25.0 K page 954 .
start:
• Diff. IAT @ • Diff. actual vs.
manifold 2 previous IAT
@ cold start downstream
vs. ECT @ throttle @ cold
cylinder start < 0.8 K
block @
cold start > • Diff. actual vs.
25.0 K previous IAT @
manifold @ cold
• Diff. IAT @ start < 0.8 K
manifold 2
@ cold start • Diff. actual vs.
vs. AAT @ previous IAT @
cold start > manifold 2 @
25.0 K cold start < 0.8 K
• Min. • Diff. actual vs.
amount of previous ECT @
faulty refer‐ cylinder block @
ence meas‐ cold start < 0.8 K
urements to • Diff. actual vs.
detect de‐ previous AAT @
fective sen‐ cold start < 0.8 K
sor 4.0 [-]
• For time >= 1.0 s
• Or
• Depending on
• Low side: mean value con‐
reference dition
measuring
Diff. IAT @ • Mean value of all
• temperature
manifold @ sensors @ cold
cold start start >= -256° C
vs. IAT @
manifold 2 • Number of valid
@ cold start sensors >= 4.00
> 25.0 K [-]
• Depending on
block heater /
solar radiation
detection
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. IAT • Time after en‐
down‐ gine start >=
stream 410.5 s
throttle @
cold start • Vehicle speed
vs. IAT @ >= 22 mph
manifold 2 • For time >= 20.0
@ cold start s
> 25.0 K
• Diff. actual IAT
• Diff. ECT @ @ downstream
cylinder throttle vs. min.
block @ IAT @ down‐
cold start stream throttle <
vs. IAT @ 4.0 K
manifold 2
@ cold start • Diff. actual IAT
> 25.0 K @ manifold vs.
min. IAT @
• Diff. AAT @ manifold < 4.0 K
cold start
vs. IAT @ • Diff. actual IAT
manifold 2 @ manifold 2 vs.
@ cold start min. IAT @
> 25.0 K manifold 2 < 4.0
K
• Min.
amount of • Diff. actual ECT
faulty refer‐ @ cylinder block
ence meas‐ vs. min. ECT @
urements to cylinder block <
detect de‐ 4.0 K
fective sen‐
sor 4.0 [-] • Diff. actual AAT
vs. min. AAT <
4.0 K
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0116 Engine • Difference • ECT @ cylinder • 1.0 s • 2 DCY – Check the
Engine Coolant between block > 39° C Engine Cool‐
Coolant Tempera‐ maximum • Once / ant Temper‐
Tempera‐ ture Sen‐ and mini‐ • IAT @ throttle DCY ature Sensor
ture Sen‐ sor @ mum tem‐ -48 – 143° C - G62- . Refer
sor 1 Cir‐ Cylinder perature of • Depending on to
cuit Block Ra‐ ECT @ cyl‐ thermostat con‐ ⇒ “3.6.17
Range/ tionality inder block trol: Engine Cool‐
Perform‐ Check < 2° C ant Temper‐
ance High • ECT @ cylinder ature Sensor
block <= n.a.° C G62 , Check‐
ing”,
• Or page 928 .
• ECT @ cylinder
block >= n.a.° C
• Engine n.a.
• And
• Engine part load
• Or
• Engine full load
• Engine speed >
1,500 RPM
• Vehicle speed
>= 12 mph
• Engine load >
0.00 %
• For time >= 20.0
– 43.0 s
• Engine idle
• Vehicle speed <
93 mph
• Or
• Fuel cut off ac‐
tive
• Or
• Engine stop
• For time >= 20.0
– 43.0 s
• Time after en‐
gine start >
100.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0117 Engine • ECT sensor • 0.5 s • 2 DCY – Check the
Engine Coolant voltage @ Engine Cool‐
Coolant Tempera‐ cylinder • Continu‐ ant Temper‐
Tempera‐ ture Sen‐ block < 0.30 ous ature Sensor
ture Sen‐ sor @ V - G62- . Refer
sor 1 Cir‐ Cylinder to
cuit Low Block ⇒ “3.6.17
Short To Engine Cool‐
Ground ant Temper‐
ature Sensor
G62 , Check‐
ing”,
page 928 .
P0118 Engine • ECT sensor • IAT @ throttle • 0.5 s • 2 DCY – Check the
Engine Coolant voltage @ >= -33° C Engine Cool‐
Coolant Tempera‐ cylinder • Continu‐ ant Temper‐
Tempera‐ ture Sen‐ block > 4.90 • Time after en‐ ous ature Sensor
ture Sen‐ sor @ V gine start > 60.0 - G62- . Refer
sor 1 Cir‐ Cylinder s to
cuit High Block ⇒ “3.6.17
Short To Engine Cool‐
Battery / ant Temper‐
Open Cir‐ ature Sensor
cuit G62 , Check‐
ing”,
page 928 .
P0121 Throttle • Normalized • Throttle adapta‐ • 0.01 s • 2 DCY – Check the
Throttle/ Position difference tion (@ initial Throttle
Pedal Po‐ Sensor 1 between start or after de‐ • Continu‐ Valve Con‐
sition Sen‐ Rationali‐ measured tection of throttle ous trol Module -
sor/Switch ty Check and mod‐ exchange or GX3- . Refer
"A" Circuit eled value checksum error) to
Range/ of mass air not active ⇒ “3.6.45
Perform‐ flow from Throttle
ance TPS 1 >= Valve Con‐
1.00 [-] trol Module
GX3 , Check‐
• Or ing”,
• Relative page 987 .
mass air
flow integral
from TPS 1
> 60.0 [-]
• Difference • 0.3 s
between
TPS 1 and • Continu‐
TPS 2 > ous
5.799° TPS
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0123 Throttle • Throttle po‐ • 0.2 s • 2 DCY – Check the
Throttle/ Position sition sen‐ Throttle
Pedal Po‐ Sensor 1 sor 1 volt‐ • Continu‐ Valve Con‐
sition Sen‐ Short To age > 4.60 ous trol Module -
sor/Switch Battery V GX3- . Refer
"A" Circuit Plus to
High ⇒ “3.6.45
Throttle
Valve Con‐
trol Module
GX3 , Check‐
ing”,
page 987 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P012B Pressure • Diff. pres‐ • Engine @ driv‐ • 3.0 s • 2 DCY – Check the In‐
Turbo‐ Sensor sure down‐ ing cycle not take Air Tem‐
charger/ Down‐ stream started the first • Continu‐ perature
Super‐ stream throttle vs. time ous Sensor -
charger In‐ Throttle manifold G42- / Mani‐
let Pres‐ Engine pressure >= • Vehicle speed < fold Absolute
sure Sen‐ Off: 7.5 kPa 1 mph Pressure
sor "A" Cir‐ Cross Sensor -
cuit Check • Diff. pres‐ G71- . Refer
Range/ sure down‐ to
Perform‐ stream ⇒ “3.6.30 In‐
ance throttle vs. take Air Tem‐
manifold perature
pressure 2 Sensor G42 /
>= 7.5 kPa Manifold Ab‐
• Or solute Pres‐
sure Sensor
• Diff. pres‐ G71 , Check‐
sure down‐ ing”,
stream page 954 .
throttle vs.
manifold
pressure >=
7.5 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.5 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(MAP 2 and
BARO) vs.
deviation
MAP to
mean value
(MAP 2 and
BARO) > 0
kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.5 kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(MAP 2 and
MAP) vs.
deviation
BARO to
mean value
(MAP 2 and
MAP) > 0
kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.5 kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(BARO and
MAP) vs.
deviation
MAP 2 to
mean value
(BARO and
MAP) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Pressure • Case 1: • Modeled pres‐
Sensor sure quotient
Down‐ • Diff. pres‐ (downstream /
stream sure down‐ upstream throt‐
Throttle stream tle) 0.30 – 0.45
Idle throttle vs. [-]
Speed: manifold
Cross pressure 2
Check >= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
< 8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Pressure • Diff. pres‐ • Engine stopped
Sensor sure down‐
Down‐ stream
stream throttle vs.
Throttle manifold
ECM pressure >=
Keep 7.5 kPa
Alive-
Time: • Diff. pres‐
Cross sure down‐
Check stream
throttle vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.5 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.5 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐ • Vehicle speed <
tion pres‐ 1 mph
sure down‐
stream • ECM keep alive
throttle to time > 10.0 s
mean value • Time after en‐
(MAP 2 and gine stop >= 4.0
BARO) vs. s
deviation
MAP to • Barometric
mean value pressure 55.0 –
(MAP 2 and 110.0 kPa
BARO) > 0
kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.5 kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(MAP 2 and
MAP) vs.
deviation
BARO to
mean value
(MAP 2 and
MAP) > 0
kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.5 kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(BARO and
MAP) vs.
deviation
MAP 2 to
mean value
(BARO and
MAP) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Pressure • Case 1: • Engine running
Sensor
Down‐ • Diff. pres‐ • Modeled pres‐
stream sure down‐ sure quotient
Throttle stream (downstream /
Engine throtte vs. upstream throt‐
Running manifold tle) > 0.45; <=
Non pressure 2 0.80 [-]
Charged >= 12.0 –
Engine: 27.0 kPa
Cross • Diff. pres‐
Check sure down‐
stream
throtte vs.
manifold
pressure >=
12.0 – 27.0
kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
< 12.0 –
27.0 kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Pressure • Case 1: • Fuel cut off ac‐ • 3.0 s
Sensor tive
Down‐ • Diff. pres‐
stream sure down‐
Throttle stream
Fuel Cut throttle vs.
Off: manifold
Cross pressure 2
Check >= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
< 8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐ • Modeled pres‐
tion pres‐ sure quotient
sure down‐ (downstream /
stream upstream throt‐
throttle to tle) 0.25 – 0.30
mean value [-]
(pressure
down‐ • For time >= 5.0 s
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
P0131 Oxygen • O2S sensor • Engine running • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage < Oxygen Sen‐
Circuit Front 0.15 V • Continu‐ sor 1 Before
Low Volt‐ Short To ous Catalytic
age Bank Ground Converter -
1 Sensor 1 GX10- . Re‐
fer to
⇒ “3.6.39
Oxygen Sen‐
sor 1 Before
Catalytic
Converter
GX10 ,
Checking”,
page 972 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0132 Oxygen • O2S sensor • Engine running • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage > Oxygen Sen‐
Circuit Front 5.20 – 5.35 • Continu‐ sor 1 Before
High Volt‐ Short To V ous Catalytic
age Bank Battery Converter -
1 Sensor 1 Plus GX10- . Re‐
fer to
⇒ “3.6.39
Oxygen Sen‐
sor 1 Before
Catalytic
Converter
GX10 ,
Checking”,
page 972 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0133 Oxygen • Dynamic • General condi‐ • 4.2 s • 2 DCY – Check the
O2 Sensor Sensors path: tions: Oxygen Sen‐
Circuit Front Re‐ • Continu‐ sor 1 Before
Slow Re‐ sponse • Lambda • Injection mode ous Catalytic
sponse Check value vs. change (DFI/ Converter -
Bank 1 modeled MFI) not active GX10- . Re‐
Sensor 1 lambda val‐ fer to
ue >= 0.90 • ECT @ cylinder
⇒ “3.6.39
[-] block >= 40° C
Oxygen Sen‐
• Or • Vehicle speed > sor 1 Before
0 mph Catalytic
• Ratio of Converter
failed diag‐ • Integrated air GX10 ,
nostic cycle mass after gear Checking”,
> n.a. [-] change > 0.0 g page 972 .
• Air mass , lower
range >= 64.01 –
114.01 mg/rev
• Air mass , upper
range <= 465.01
– 565.01 mg/rev
• Counter of inte‐
grated mass for
fuel in oil <
255.00 [-]
• Lambda sensor
dynamic error
not active
• And
• Time after en‐
gine start >= 0.0
s
• Or
• Integrated air
mass per cylin‐
der >= 0.680 kg
• Depending on
canister and cat‐
alyst purge:
• Evap purge n.a.
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Canister load
calculation n.a.
• Or
• Evap purge n.a.
• Canister load <=
n.a. [-]
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Case 1:
• O2S front n.a.
• Lambda stimu‐
lation n.a.
• Upper limit of
lambda control‐
ler output n.a.
• Lower limit of
lambda control‐
ler output n.a.
• Engine speed
n.a. RPM
• Air mass n.a.
mg/rev
• MAF > n.a. kg/h
• Catalyst purge
n.a.
• And
• Depending on
limited dynamic
conditions:
• Integrated air
mass < n.a. g
• Dynamic engine
speed < n.a. g
• Dynamic air
mass < n.a. mg/
rev
• Dynamic lamb‐
da < n.a. %
• Or
• Dynamic engine
speed < n.a.
RPM
• Diff. actual en‐
gine load vs. fil‐
tered engine
load in limited
dynamic condi‐
tions, lower
range >= n.a. kg/
h
• Diff. actual en‐
gine load vs. fil‐
tered engine
load in limited
dynamic condi‐
tions, upper
range <= n.a. kg/
h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Dynamic torque
< n.a. [-]
• Case 2:
• Lambda set val‐
ue adjustment
for conditioning
and measuring
active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Delay path: • General condi‐ • 6.0 s
tions:
• Lambda de‐
lay value vs. • Air mass , lower
modeled range >= 80.01 –
lambda val‐ 130.01 mg/rev
ue > 0.90 [-]
• Air mass , upper
range <= 450.01
– 550.00 mg/rev
• Integrated air
mass per cylin‐
der >= 0.93 –
1.37 kg
• Vehicle speed
>= 0 mph
• Time after en‐
gine start >= 0.0
s
• Injection mode
change (DFI/
MFI) not active
• Counter of inte‐
grated mass for
fuel in oil < 35.00
[-]
• Engine speed
960 – 3,008
RPM
• MAF (intake air
rate) 5.0 – 235.0
kg/h
• Vehicle speed
>= 0 mph
• Lambda sensor
dynamic error
not active
• And
• Depending on
dynamic condi‐
tions:
• Dynamic engine
speed < 512
RPM
• Dynamic torque
< 130.0 Nm
• Dynamic MAF <
80.0 kg/h
• For time >= 0.6 s
• And
• Depending on
canister and cat‐
alyst purge:
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge n.a. • Continu‐
ous
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Canister load
calculation n.a.
• Or
• Evap purge n.a.
• Canister load <=
n.a. [-]
P0135 Oxygen • O2S ceram‐ • Heater com‐ • 20.0 s • 2 DCY – Check the
O2 Sensor Sensors ic tempera‐ manded on Oxygen Sen‐
Heater Cir‐ Heater ture < 680° • Continu‐ sor 1 Before
cuit Bank 1 Front C • For time >= 17.0 ous Catalytic
Sensor 1 Function‐ s Converter -
al Check GX10- . Re‐
fer to
⇒ “3.6.39
Oxygen Sen‐
sor 1 Before
Catalytic
Converter
GX10 ,
Checking”,
page 972 .
P0137 Oxygen • O2S sensor • O2S heater ac‐ • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage < tive Oxygen Sen‐
Circuit Rear 0.15 V • Continu‐ sor 1 After
Low Volt‐ Short To ous Catalytic
age Bank Ground Converter -
1 Sensor 2 GX7- . Refer
to
⇒ “3.6.38
Oxygen Sen‐
sor 1 After
Catalytic
Converter
GX7 , Check‐
ing”,
page 970 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0138 Oxygen • O2S sensor • O2S heater ac‐ • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage > tive Oxygen Sen‐
Circuit Rear 5.2 – 5.35 V • Continu‐ sor 1 After
High Volt‐ Short To ous Catalytic
age Bank Battery Converter -
1 Sensor 2 GX7- . Refer
to
⇒ “3.6.38
Oxygen Sen‐
sor 1 After
Catalytic
Converter
GX7 , Check‐
ing”,
page 970 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P013A Oxygen • Gradient • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors sensor volt‐ tions: (FTP75: Oxygen Sen‐
Slow Re‐ Rear age < 800.0 50.0) s sor 1 After
sponse - Close mV/s • Intrusive lambda Catalytic
Rich to The Gap ramp request • Once / Converter -
Lean Bank Condi‐ not active DCY GX7- . Refer
1 Sensor 2 tions: Re‐ • Internal resist‐ to
sponse ance O2S rear < ⇒ “3.6.38
Check 3,000.0 Ohm Oxygen Sen‐
sor 1 After
• Counter of inte‐ Catalytic
grated mass for Converter
fuel in oil < 35.00 GX7 , Check‐
[-] ing”,
page 970 .
• Catalyst monitor
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 19 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 2.200 -
2,700 kg
• Internal resist‐
ance O2S rear
<= 1,000 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P013B Oxygen • Gradient • General condi‐ • 0 (FTP75: • 2 DCY – Check the
O2 Sensor Sensors sensor volt‐ tions: 50) [s] Oxygen Sen‐
Slow Re‐ Rear Re‐ age < 800.0 sor 1 After
sponse - sponse mV/s • Intrusive lambda • Once / Catalytic
Lean to Check ramp request DCY Converter -
Rich Bank not active GX7- . Refer
1 Sensor 2 • Internal resist‐ to
ance O2S rear < ⇒ “3.6.38
3,000.0 Ω Oxygen Sen‐
sor 1 After
• Counter of inte‐ Catalytic
grated mass for Converter
fuel in oil < 35.00 GX7 , Check‐
[-] ing”,
page 970 .
• Catalyst monitor
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 19 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
<= 1,000 Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P013C Oxygen • Gradient • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors sensor volt‐ tions: (FTP75: Oxygen Sen‐
Slow Re‐ Rear age < 800.0 50.0) s sor 2 After
sponse - Bank 2 mV/s • Intrusive lambda Catalytic
Rich to Close ramp request • Once / Converter -
Lean Bank The Gap not active DCY GX8- . Refer
2 Sensor 2 Condi‐ • Internal resist‐ to
tions: Re‐ ance O2S rear < ⇒ “3.6.40
sponse 3,000.0 Ohm Oxygen Sen‐
Check sor 2 After
• Counter of inte‐ Catalytic
grated mass for Converter
fuel in oil < 35.00 GX8 , Check‐
[-] ing”,
page 976 .
• Catalyst monitor
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 19 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
<= 1,000 Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P013D Oxygen • Gradient • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors sensor volt‐ tions: (FTP75: Oxygen Sen‐
Slow Re‐ Rear age < 800.0 50.0) s sor 2 After
sponse - Bank 2 mV/s • Intrusive lambda Catalytic
Lean to Re‐ ramp request • Once / Converter -
Rich Bank sponse not active DCY GX8- . Refer
2 Sensor 2 Check • Internal resist‐ to
ance O2S rear < ⇒ “3.6.40
3,000.0 Ohm Oxygen Sen‐
sor 2 After
• Counter of inte‐ Catalytic
grated mass for Converter
fuel in oil < 35.00 GX8 , Check‐
[-] ing”,
page 976 .
• Catalyst monitor
lambda modula‐
tion request ac‐
tive
• Vehicle speed
>= 19 mph
• BARO >= 63.0
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted [-]
• Coasting func‐
tion n.a
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
<= 1,000 Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P013E Oxygen • Sensor sig‐ • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors nal delay tions: (FTP75: Oxygen Sen‐
Delayed Rear time > 0.8 s 50.0) s sor 1 After
Response Bank 2 • Intrusive lambda Catalytic
- Rich to Delayed ramp request • Once / Converter -
Lean Bank Re‐ not active DCY GX7- . Refer
1 Sensor 2 sponse • Catalyst monitor to
Monitor‐ lambda modula‐ ⇒ “3.6.38
ing, De‐ tion request ac‐ Oxygen Sen‐
lay Meas‐ tive sor 1 After
urement Catalytic
• Vehicle speed Converter
>= 19 mph GX7 , Check‐
ing”,
• BARO >= 63.0 page 970 .
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted [-]
• Coasting func‐
tion n.a
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
<= 1,000 Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P013F Oxygen • Sensor sig‐ • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors nal delay tions: (FTP75: Oxygen Sen‐
Delayed Rear time > 0.8 s 50.0) s sor 1 After
Response Bank 2 • Intrusive lambda Catalytic
- Lean to Delayed ramp request • Once / Converter -
Rich Bank Re‐ not active DCY GX7- . Refer
1 Sensor 2 sponse • Catalyst monitor to
Monitor‐ lambda modula‐ ⇒ “3.6.38
ing, De‐ tion request ac‐ Oxygen Sen‐
lay Meas‐ tive sor 1 After
urement Catalytic
• Vehicle speed Converter
>= 19 mph GX7 , Check‐
ing”,
• BARO >= 63.0 page 970 .
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted [-]
• Coasting func‐
tion n.a
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
<= 1,000 Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Boost volt‐
Valves age > 75.0
Supply V
Voltage
Out Of
Range
High
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P014A Oxygen • Sensor sig‐ • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors nal delay tions: (FTP75: Oxygen Sen‐
Delayed Rear time > 0.8 s 50.0) s sor 2 After
Response Bank 2 • Intrusive lambda Catalytic
- Rich to Delayed ramp request • Once / Converter -
Lean Bank Re‐ not active DCY GX8- . Refer
2 Sensor 2 sponse • Catalyst monitor to
Monitor‐ lambda modula‐ ⇒ “3.6.40
ing, De‐ tion request ac‐ Oxygen Sen‐
lay Meas‐ tive sor 2 After
urement Catalytic
• Vehicle speed Converter
>= 19 mph GX8 , Check‐
ing”,
• BARO >= 63.0 page 976 .
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted [-]
• Coasting func‐
tion n.a
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
<= 1,000 Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P014B Oxygen • Sensor sig‐ • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors nal delay tions: (FTP75: Oxygen Sen‐
Delayed Rear time > 0.8 s 50.0) s sor 2 After
Response Bank 2 • Intrusive lambda Catalytic
- Lean to Delayed ramp request • Once / Converter -
Rich Bank Re‐ not active DCY GX8- . Refer
2 Sensor 2 sponse • Catalyst monitor to
Monitor‐ lambda modula‐ ⇒ “3.6.40
ing, De‐ tion request ac‐ Oxygen Sen‐
lay Meas‐ tive sor 2 After
urement Catalytic
• Vehicle speed Converter
>= 19 mph GX8 , Check‐
ing”,
• BARO >= 63.0 page 976 .
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated air
mass, catalyst
temp. conditions
fulfilled >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.00 mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass to start di‐
agnosis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted [%]
• Coasting func‐
tion n.a
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Canister purge
valve (closing
time) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Integrated air
mass per cylin‐
der >= 1.85 kg
• Internal resist‐
ance O2S rear
<= 1,000 Ohm
P0151 Oxygen • O2S sensor • Engine running • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage < Oxygen Sen‐
Circuit Front 0.15 V • Continu‐ sor 2 Before
Low Volt‐ Bank 2 ous Catalytic
age Bank Short To Converter -
2 Sensor 1 Ground GX11- . Re‐
fer to
⇒ “3.6.41
Oxygen Sen‐
sor 2 Before
Catalytic
Converter
GX11 ,
Checking”,
page 978 .
P0152 Oxygen • O2S sensor • Engine running • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage > Oxygen Sen‐
Circuit Front 5.20 – 5.35 • Continu‐ sor 2 Before
High Volt‐ Bank 2 V ous Catalytic
age Bank Short To Converter -
2 Sensor 1 Battery GX11- . Re‐
Plus fer to
⇒ “3.6.41
Oxygen Sen‐
sor 2 Before
Catalytic
Converter
GX11 ,
Checking”,
page 978 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0153 Oxygen • Dynamic • General condi‐ • 4.2 s • 2 DCY – Check the
O2 Sensor Sensors path: tions: Oxygen Sen‐
Circuit Front • Continu‐ sor 2 Before
Slow Re‐ Bank 2 • Lambda • Injection mode ous Catalytic
sponse Re‐ value vs. change (DFI/ Converter -
Bank 2 sponse modeled MFI) not active GX11- . Re‐
Sensor 1 Check lambda val‐ fer to
ue >= 0.90 • ECT @ cylinder
⇒ “3.6.41
[-] block >= 40° C
Oxygen Sen‐
• Or • Vehicle speed > sor 2 Before
0 mph Catalytic
• Ratio of Converter
failed diag‐ • Integrated air GX11 ,
nostic cycle mass after gear Checking”,
> n.a. [-] change > 0.0 g page 978 .
• Air mass , lower
range >= 64.01 –
114.01 mg/rev
• Air mass , upper
range <= 465.01
– 565.01 mg/rev
• Counter of inte‐
grated mass for
fuel in oil < 255.0
[-]
• Lambda sensor
dynamic error
not active
• And
• Time after en‐
gine start >= 0.0
s
• Or
• Integrated air
mass per cylin‐
der >= 0.680 kg
• Depending on
canister and cat‐
alyst purge:
• Evap purge n.a.
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Canister load
calculation n.a.
• Or
• Evap purge n.a.
• Canister load <=
n.a. [-]
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Case 1:
• O2S front n.a.
• Lambda stimu‐
lation n.a.
• Upper limit of
lambda control‐
ler output n.a.
• Lower limit of
lambda control‐
ler output n.a.
• Engine speed
n.a. RPM
• Air mass n.a.
mg/rev
• MAF > n.a. kg/h
• Catalyst purge
n.a.
• And
• Depending on
limited dynamic
conditions:
• Integrated air
mass < n.a. g
• Dynamic engine
speed < n.a. g
• Dynamic air
mass < n.a. mg/
rev
• Dynamic lamb‐
da < n.a. %
• Or
• Dynamic engine
speed < n.a.
RPM
• Diff. actual en‐
gine load vs. fil‐
tered engine
load in limited
dynamic condi‐
tions, lower
range >= n.a. kg/
h
• Diff. actual en‐
gine load vs. fil‐
tered engine
load in limited
dynamic condi‐
tions, upper
range <= n.a. kg/
h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Dynamic torque
< n.a.[-]
• Case 2:
• Lambda set val‐
ue adjustment
for conditioning
and measuring
active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Delay Path: • General condi‐ • 6.0 s
tions:
• Lambda de‐
lay value vs. • Air mass , lower
modeled range >= 80.01 –
lambda val‐ 130.01 mg/rev
ue > 0.90 [-]
• Air mass , upper
range <= 450.01
– 550.00 mg/rev
• Integrated air
mass per cylin‐
der >= 0.930 –
1.370 kg
• Vehicle speed
>= 0 mph
• Time after en‐
gine start >= 0.0
s
• Injection mode
change (DFI/
MFI) not active
• Counter of inte‐
grated mass for
fuel in oil < 35.0
[-]
• Engine speed
960 – 3,008
RPM
• MAF (intake air
rate) 5.0 – 235.0
kg/h
• Vehicle speed
>= 0 mph
• Lambda sensor
dynamic error
not active
• And
• Depending on
dynamic condi‐
tions:
• Dynamic engine
speed < 512
RPM
• Dynamic torque
< 130.0 Nm
• Dynamic MAF <
80.0 kg/h
• For time >= 0.6 s
• And
• Depending on
canister and cat‐
alyst purge:
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge n.a. • Continu‐
ous
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Or
• Evap purge n.a.
• Canister load
calculation n.a.
• Or
• Evap purge n.a.
• Canister load <=
n.a. [-]
P0157 Oxygen • O2S sensor • O2S heater ac‐ • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage < tive Oxygen Sen‐
Circuit Rear 0.15 V • Continu‐ sor 2 After
Low Volt‐ Bank 2 ous Catalytic
age Bank Short To Converter -
2 Sensor 2 Ground GX8- . Refer
to
⇒ “3.6.40
Oxygen Sen‐
sor 2 After
Catalytic
Converter
GX8 , Check‐
ing”,
page 976 .
P0158 Oxygen • O2S sensor • O2S heater ac‐ • 0.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage > tive Oxygen Sen‐
Circuit Rear 5.2 – 5.35 V • Continu‐ sor 2 After
High Volt‐ Bank 2 ous Catalytic
age Bank Short To Converter -
2 Sensor 2 Battery GX8- . Refer
to
⇒ “3.6.40
Oxygen Sen‐
sor 2 After
Catalytic
Converter
GX8 , Check‐
ing”,
page 976 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0160 Oxygen • Internal re‐ • 2.5 s • 2 DCY – Check the
O2 Sensor Sensors sistance of Oxygen Sen‐
Circuit No Rear O2S (bina‐ • Continu‐ sor 2 After
Activity Bank 2 ry) > ous Catalytic
Detected Open Cir‐ 23,000.0 Converter -
Bank 2 cuit Ohm GX8- . Refer
Sensor 2 to
⇒ “3.6.40
Oxygen Sen‐
sor 2 After
Catalytic
Converter
GX8 , Check‐
ing”,
page 976 .
P0161 Oxygen • O2S inter‐ • Heater com‐ • 20.0 s • 2 DCY – Check the
O2 Sensor Sensors nal resist‐ manded on Oxygen Sen‐
Heater Cir‐ Heater ance (bina‐ • Once / sor 2 After
cuit Bank 2 Rear 2 ry) >= • For time >= 30.0 DCY Catalytic
Sensor 2 Out Of 1,000.0 – s Converter -
Range 23,000.0 Ω GX8- . Refer
High to
⇒ “3.6.40
Oxygen Sen‐
sor 2 After
Catalytic
Converter
GX8 , Check‐
ing”,
page 976 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0171 Fuel Sys‐ • Lambda • Lambda control • 180.0 s • 2 DCY – Check the
System tem Too controller closed loop Fuel Delivery
Too Lean Lean output > • Continu‐ Unit - GX1- .
Bank 1 37.0 % • Mass air flow > ous Refer to
76.0 mg/rev ⇒ “3.6.23
• Engine speed > Fuel Delivery
544 RPM Unit GX1 ,
Checking”,
• ECT @ cylinder page 940 .
block > 70° C
– Check the
• IAT at intake fuel pressure
manifold > -11° regulator and
C residual
pressure.
• AAT > -48° C Refer to ap‐
• Ethanol value propriate re‐
n.a. pair manual.
• And – Check the
pressure in
• Evap purge the fuel sys‐
valve closed tem for out of
• Or spec condi‐
tions before
• Canister load <= diagnosing
2.00 [-] the pressure
sensor. Re‐
• Evap purge flow fer to Fuel
at max. value System Me‐
• Or chanical
Testing in
• Depending on ⇒ “3.1 Pre‐
canister purge liminary
min: Check”,
page 20 .
• Lower limit of
lambda control‐ – Check the
ler output n.a. fuel injectors.
Refer to
• Or ⇒ “3.6.24
• Upper limit of Fuel Injec‐
lambda control‐ tors, Check‐
ler output n.a. ing”,
page 942 .
• And
– Check intake
• Evap purge flow system visu‐
at min. value ally for leaks
(false air).
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0172 Fuel Sys‐ • Lambda • Lambda control • 180.0 s • 2 DCY – Check the
System tem Too controller closed loop Fuel Delivery
Too Rich Rich output < • Continu‐ Unit - GX1- .
Bank 1 -37.0 % • Mass air flow > ous Refer to
76.0 mg/rev ⇒ “3.6.23
• Engine speed > Fuel Delivery
544 RPM Unit GX1 ,
Checking”,
• ECT @ cylinder page 940 .
block > 70° C
– Check the
• IAT at intake fuel pressure
manifold > -11° regulator and
C residual
pressure.
• AAT > -48° C Refer to ap‐
• Ethanol value propriate re‐
n.a. pair manual.
• Oil dilution not – Check the
detected fuel injectors.
Refer to
• And ⇒ “3.6.24
• Evap purge Fuel Injec‐
valve closed tors, Check‐
ing”,
• Or page 942 .
• Canister load <= – Check the
2.00 [-] Oxygen Sen‐
• Evap purge flow sor 1 Before
at max. value Catalytic
Converter -
• Or GX10- . Re‐
fer to
• Depending on ⇒ “3.6.39
canister purge Oxygen Sen‐
min: sor 1 Before
Catalytic
• Lower limit of Converter
lambda control‐ GX10 ,
ler output n.a. Checking”,
• Or page 972 .
• Upper limit of – Check intake
lambda control‐ system visu‐
ler output n.a. ally for leaks
(false air).
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0174 Fuel Sys‐ • Lambda • Lambda control • 180.0 s • 2 DCY – Check the
System tem Too controller closed loop Fuel Delivery
Too Lean Lean output > • Continu‐ Unit - GX1- .
Bank 2 37.0 % • Mass air flow > ous Refer to
76.0 mg/rev ⇒ “3.6.23
• Engine speed > Fuel Delivery
544 RPM Unit GX1 ,
Checking”,
• ECT @ cylinder page 940 .
block > 70° C
– Check the
• IAT at intake fuel pressure
manifold > -11° regulator and
C residual
pressure.
• AAT > -48° C Refer to ap‐
• Ethanol value propriate re‐
n.a. pair manual.
• And – Check the
pressure in
• Evap purge the fuel sys‐
valve closed tem for out of
• Or spec condi‐
tions before
• Canister load <= diagnosing
2.00 [-] the pressure
sensor. Re‐
• Evap purge flow fer to Fuel
at max. value System Me‐
• Or chanical
Testing in
• Depending on ⇒ “3.1 Pre‐
canister purge liminary
min: Check”,
page 20 .
• Lower limit of
lambda control‐ – Check the
ler output n.a. Oxygen Sen‐
sor 2 Before
• Or Catalytic
• Upper limit of Converter -
lambda control‐ GX11- . Re‐
ler output n.a. fer to
⇒ “3.6.41
• And Oxygen Sen‐
sor 2 Before
• Evap purge flow Catalytic
at min. value Converter
GX11 ,
Checking”,
page 978 .
– Check intake
system visu‐
ally for leaks
(false air).
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0175 Fuel Sys‐ • Lambda • Lambda control • 180.0 s • 2 DCY – Check the
System tem Too controller closed loop Fuel Delivery
Too Rich Rich output < • Continu‐ Unit - GX1- .
Bank 2 -37.0 % • Mass air flow > ous Refer to
76.0 mg/rev ⇒ “3.6.23
• Engine speed > Fuel Delivery
544 RPM Unit GX1 ,
Checking”,
• ECT @ cylinder page 940 .
block > 70° C
– Check the
• IAT at intake fuel pressure
manifold > -11° regulator and
C residual
pressure.
• AAT > -48° C Refer to ap‐
• Ethanol value propriate re‐
n.a. pair manual.
• Oil dilution not – Check the
detected Oxygen Sen‐
sor 2 Before
• And Catalytic
• Evap purge Converter -
valve closed GX11- . Re‐
fer to
• Or ⇒ “3.6.41
Oxygen Sen‐
• Canister load <= sor 2 Before
2.00 [-] Catalytic
• Evap purge flow Converter
at max. value GX11 ,
Checking”,
• Or page 978 .
• Depending on – Check intake
canister purge system visu‐
min: ally for leaks
(false air).
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P017B Engine • Difference • ECT @ cylinder • 10.0 s • 2 DCY – Check the
Cylinder Coolant between head -128 – 40° Engine Cool‐
Head Tempera‐ modelled C • Once / ant Temper‐
Tempera‐ ture Sen‐ and meas‐ DCY ature Sensor
ture Sen‐ sor @ ured cylin‐ • Time after en‐ - G62- . Refer
sor Circuit Cylinder der head gine start > 0.0 s to
Range/ Head Ra‐ tempera‐ ⇒ “3.6.17
Perform‐ tionality ture > 0.0 K Engine Cool‐
ance Check ant Temper‐
Low ature Sensor
G62 , Check‐
ing”,
page 928 .
– Check the
Engine Tem‐
perature
Control Sen‐
sor - G694- .
Refer to
⇒ “3.6.19
Engine Tem‐
perature
Control Sen‐
sor G694 ,
Checking”,
page 932 .
– Check the
Cylinder
Head Cool‐
ant Valve -
N489- . Refer
to
⇒ “3.6.15
Cylinder
Head Cool‐
ant Valve
N489 ,
Checking”,
page 924 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P017C Engine • ECT sensor • 0.5 s • 2 DCY – Check the
Cylinder Coolant voltage @ Engine Cool‐
Head Tempera‐ cylinder • Continu‐ ant Temper‐
Tempera‐ ture Sen‐ head <= ous ature Sensor
ture Sen‐ sor @ 0.30 V - G62- . Refer
sor Circuit Cylinder to
Low Head ⇒ “3.6.17
Short To Engine Cool‐
Ground ant Temper‐
ature Sensor
G62 , Check‐
ing”,
page 928 .
– Check the
Engine Tem‐
perature
Control Sen‐
sor - G694- .
Refer to
⇒ “3.6.19
Engine Tem‐
perature
Control Sen‐
sor G694 ,
Checking”,
page 932 .
– Check the
Cylinder
Head Cool‐
ant Valve -
N489- . Refer
to
⇒ “3.6.15
Cylinder
Head Cool‐
ant Valve
N489 ,
Checking”,
page 924 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P017D Engine • ECT sensor • IAT @ throttle • 0.5 s • 2 DCY – Check the
Cylinder Coolant voltage @ >= -33° C Engine Cool‐
Head Tempera‐ cylinder • Continu‐ ant Temper‐
Tempera‐ ture Sen‐ head > 4.70 • Time after en‐ ous ature Sensor
ture Sen‐ sor @ V gine start > 60.0 - G62- . Refer
sor Circuit Cylinder s to
High Head ⇒ “3.6.17
Short To Engine Cool‐
Battery / ant Temper‐
Open Cir‐ ature Sensor
cuit G62 , Check‐
ing”,
page 928 .
– Check the
Engine Tem‐
perature
Control Sen‐
sor - G694- .
Refer to
⇒ “3.6.19
Engine Tem‐
perature
Control Sen‐
sor G694 ,
Checking”,
page 932 .
– Check the
Cylinder
Head Cool‐
ant Valve -
N489- . Refer
to
⇒ “3.6.15
Cylinder
Head Cool‐
ant Valve
N489 ,
Checking”,
page 924 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0190 Fuel Sys‐ • High fuel • 2.0 s • 2 DCY – Check the
Fuel Pres‐ tem Pres‐ pressure pressure in
sure Reg‐ sure Sen‐ sensor volt‐ • Continu‐ the fuel sys‐
ulator 1 sor, High age > 4.80 ous tem for out of
Control Pressure V spec condi‐
Circuit/ Side tions before
Open Short To diagnosing
Battery / the pressure
Open Cir‐ sensor. Re‐
cuit fer to Fuel
System Me‐
chanical
Testing in
⇒ “3.1 Pre‐
liminary
Check”,
page 20 .
– Check the
Fuel Pres‐
sure Sensor -
G247- . Re‐
fer to
⇒ “3.6.27
Fuel Pres‐
sure Sensor
G247 ,
Checking”,
page 948 .
P0191 Fuel Rail, • Fuel pres‐ • Engine running • 2.5 s • 2 DCY – Check the
Fuel Rail High sure > pressure in
Pressure Pressure 27,900.09 • Engine speed < • Continu‐ the fuel sys‐
Sensor Side Out kPa 3,264 RPM ous tem for out of
Circuit Of Range • Time after en‐ spec condi‐
Range/ High gine start > 10.0 tions before
Perform‐ s diagnosing
ance Bank the pressure
1 sensor. Re‐
fer to Fuel
System Me‐
chanical
Testing in
⇒ “3.1 Pre‐
liminary
Check”,
page 20 .
– Check the
Fuel Pres‐
sure Sensor -
G247- . Re‐
fer to
⇒ “3.6.27
Fuel Pres‐
sure Sensor
G247 ,
Checking”,
page 948 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0192 Fuel Sys‐ • High fuel • 2.0 s • 2 DCY – Check the
Fuel Rail tem Pres‐ pressure pressure in
Pressure sure Sen‐ sensor volt‐ • Continu‐ the fuel sys‐
Sensor sor, High age < 0.20 ous tem for out of
Circuit Pressure V spec condi‐
Low Bank Side tions before
1 Short To diagnosing
Ground the pressure
sensor. Re‐
fer to Fuel
System Me‐
chanical
Testing in
⇒ “3.1 Pre‐
liminary
Check”,
page 20 .
– Check the
Fuel Pres‐
sure Sensor -
G247- . Re‐
fer to
⇒ “3.6.27
Fuel Pres‐
sure Sensor
G247 ,
Checking”,
page 948 .
P0201 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 1 Valves tern for active CRK Cylinder 1
Injector Open Cir‐ open circuit Fuel Injector
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ - N30- . Refer
stage diag‐ block >= -48° C ous to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via
Error power
stage diag‐
nosis detec‐
ted
• And
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Injector low • ECT @ cylinder
side switch block >= -48° C
current
(hardware • Engine speed <
values) 7,000 RPM
driver stage • Injection time >=
internal val‐ 0.0 s
ue
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
P0202 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 2 Valves tern for active CRK Cylinder 2
Injector Open Cir‐ open circuit Fuel Injector
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ - N31- . Refer
stage diag‐ block >= -48° C ous to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via • ECT @ cylinder
Error power block >= -48° C
stage diag‐ • Engine speed <
nosis detec‐ 7,000 RPM
ted
• Injection time >=
• And 0.0 s
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
P0203 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 3 Valves tern for active CRK Cylinder 3
Injector Open Cir‐ open circuit Fuel Injector
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ - N32- . Refer
stage diag‐ block >= -48° C ous to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via • ECT @ cylinder
Error power block >= -48° C
stage diag‐ • Engine speed <
nosis detec‐ 7,000 RPM
ted
• Injection time >=
• And 0.0 s
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
P0204 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 4 Valves tern for active CRK Cylinder 4
Injector Open Cir‐ open circuit Fuel Injector
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ - N33- . Refer
stage diag‐ block >= -48° C ous to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via • ECT @ cylinder
Error power block >= -48° C
stage diag‐ • Engine speed <
nosis detec‐ 7,000 RPM
ted
• Injection time >=
• And 0.0 s
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
P0205 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 5 Valves tern for active CRK Cylinder 5
Injector Open Cir‐ open circuit Fuel Injector
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ - N83- . Refer
stage diag‐ block >= -48° C ous to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via • ECT @ cylinder
Error power block >= -48° C
stage diag‐ • Engine speed <
nosis detec‐ 7,000 RPM
ted
• Injection time >=
• And 0.0 s
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
P0206 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 6 Valves tern for active CRK Cylinder 6
Injector Open Cir‐ open circuit Fuel Injector
"A" Circuit cuit via power • ECT @ cylinder • Continu‐ - N84- . Refer
stage diag‐ block >= -48° C ous to
nosis detec‐ • Engine speed < ⇒ “3.6.24
ted 7,000 RPM Fuel Injec‐
tors, Check‐
• Injector low • Injection time >= ing”,
side voltage 0.0 s page 942 .
< 2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Indetermi‐ • Engine running
Valves nate fault
Electrical pattern via • ECT @ cylinder
Error power block >= -48° C
stage diag‐ • Engine speed <
nosis detec‐ 7,000 RPM
ted
• Injection time >=
• And 0.0 s
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
• Or
• Injector low
side voltage
< 2.0 V
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
voltage <
2.0 V
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Injector low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector low
side switch
current driv‐
er stage in‐
ternal value
• Or
• Injector
load resist‐
ance to
ground and
battery >
20.0 Ohm
• Injector
high side
switch cur‐
rent driver
stage inter‐
nal value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0222 Throttle • Throttle po‐ • 0.2 s • 2 DCY – Check the
Throttle/ Position sition sen‐ Throttle
Pedal Po‐ Sensor 2 sor 2 volt‐ • Continu‐ Valve Con‐
sition Sen‐ Short To age < 0.17 ous trol Module -
sor/Switch Ground V GX3- . Refer
"B" Circuit to
Low ⇒ “3.6.45
Throttle
Valve Con‐
trol Module
GX3 , Check‐
ing”,
page 987 .
P0223 Throttle • Throttle po‐ • 0.2 s • 2 DCY – Check the
Throttle/ Position sition sen‐ Throttle
Pedal Po‐ Sensor 2 sor 2 volt‐ • Continu‐ Valve Con‐
sition Sen‐ Short To age > 4.85 ous trol Module -
sor/Switch Battery V GX3- . Refer
"B" Circuit Plus to
High ⇒ “3.6.45
Throttle
Valve Con‐
trol Module
GX3 , Check‐
ing”,
page 987 .
P0230 CAN: • Fuel pump • Engine on • 2.0 s • 2 DCY – Check the
Fuel Pump Fuel sensor: Fuel Delivery
Primary Pump short to • Continu‐ Unit - GX1- .
Circuit CAN ground fail‐ ous Refer to
Malfunc‐ Commu‐ ure feed‐ ⇒ “3.6.23
tion nication back >= 2.0 Fuel Delivery
With Fuel [-] Unit GX1 ,
Pump Checking”,
• Fuel pump • 2.2 s page 940 .
sensor:
open circuit • Continu‐
failure feed‐ ous
back >= 2.0
[-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0235 Manifold • Received • 0.5 s • 2 DCY – Check the In‐
Turbo‐ Absolute data im‐ take Air Tem‐
charger/ Pressure plausible • Continu‐ perature
Super‐ (MAP) message ous Sensor -
charger Sensor G42- / Mani‐
Boost commu‐ fold Absolute
Sensor "A" nication Pressure
Circuit with MAP Sensor -
G71- . Refer
to
⇒ “3.6.30 In‐
take Air Tem‐
perature
Sensor G42 /
Manifold Ab‐
solute Pres‐
sure Sensor
G71 , Check‐
ing”,
page 954 .
– Check the
charge air
system for
proper seal.
Refer to En‐
gine Me‐
chanical,
Fuel Injec‐
tion and Igni‐
tion, Charge
Air System.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0236 Manifold • Diff. pres‐ • Engine @ driv‐ • 3.0 s • 2 DCY – Check the
Turbo‐ Pressure sure down‐ ing cycle not Charge Air
charger/ Sensor stream started the first • Continu‐ Pressure
Super‐ Engine throttle vs. time ous Sensor -
charger Off: manifold G31- / Intake
Boost Cross pressure >= • Vehicle speed < Manifold
Sensor "A" Check 7.5 kPa 1 mph Temperature
Circuit Sensor -
Range/ • Diff. mani‐ G72- . Refer
Perform‐ fold pres‐ to
ance sure vs. ⇒ “3.6.10
manifold Charge Air
pressure 2 Pressure
>= 7.5 kPa Sensor G31 /
• Or Intake Mani‐
fold Temper‐
• Diff. pres‐ ature Sensor
sure down‐ G72 , Check‐
stream ing”,
throttle vs. page 914 .
manifold
pressure >= – Check the
7.5 kPa charge air
system for
• Diff. baro‐ proper seal.
metric pres‐ Refer to En‐
sure vs. gine Me‐
manifold chanical,
pressure >= Fuel Injec‐
7.5 kPa tion and Igni‐
tion, Charge
• Or Air System.
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.5 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion pres‐
sure MAP to
mean value
(MAP 2 and
BARO) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(MAP2 and
BARO) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.5 kPa
• Diff. devia‐
tion pres‐
sure MAP to
mean value
(MAP 2 and
pressure
down‐
stream
throttle) vs.
deviation
BARO to
mean value
(MAP2 and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion pres‐
sure MAP to
mean value
(BARO and
pressure
down‐
stream
throttle) vs.
deviation
MAP 2 to
mean value
(BARO and
pressure
down‐
stream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Manifold • Case 1: • Modeled pres‐
Pressure sure quotient
Sensor • Diff. mani‐ (downstream /
Idle fold pres‐ upstream throt‐
Speed: sure vs.
Cross manifold
Check pressure 2
>= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
< 8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐ tle) 0.30 – 0.45
tion pres‐ [-]
sure MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion pres‐
sure MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Manifold • Diff. pres‐ • Engine stopped
Pressure sure down‐
Sensor stream
ECM throttle vs.
Keep manifold
Alive pressure >=
Time: 7.5 kPa
Cross
Check • Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.5 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.5 kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.5 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐ • Vehicle speed <
tion MAP to 1 mph
mean value
(MAP 2 and • ECM keep alive
BARO) vs. time > 10.0 s
deviation • Time after en‐
pressure gine stop >= 4.0
down‐ s
stream
throttle to • Barometric
mean value pressure 55.0 –
(MAP2 and 110.0 kPa
BARO) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.5 kPa
• Diff. devia‐
tion MAP to
mean value
(MAP 2 and
pressure
down‐
stream
throttle) vs.
deviation
BARO to
mean value
(MAP 2 and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion MAP to
mean value
(BARO and
pressure
down‐
stream
throttle) vs.
deviation
MAP 2 to
mean value
(BARO and
pressure
down‐
stream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Manifold • Case 1: • Engine running
Pressure
Sensor • Diff. pres‐
Engine sure down‐
Running stream
Non throttle vs.
Charged manifold
Engine: pressure >=
Cross 12.0 – 27.0
Check kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
< 12.0 –
27.0 kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
12.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐ • Modeled pres‐
tion MAP to sure quotient
mean value (downstream /
(pressure upstream throt‐
down‐ tle) > 0.45; <=
stream 0.80 [-]
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Manifold • Case 1: • Fuel cut off ac‐
Pressure tive
Sensor • Diff. mani‐
Fuel Cut fold pres‐ • Modeled pres‐
Off: sure vs. sure quotient
Cross manifold (downstream /
Check pressure 2 upstream throt‐
>= 8.0 – tle) 0.25 – 0.30
27.0 kPa [-]
• Diff. pres‐ • For time >= 5.0 s
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
< 8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0240 Manifold • Diff. pres‐ • Engine @ driv‐ • 3.0 s • 2 DCY – Check the
Turbo‐ Pressure sure down‐ ing cycle not Charge Air
charger/ Sensor 2 stream started the first • Continu‐ Pressure
Super‐ Engine throttle vs. time ous Sensor 2 -
charger Off: manifold G447- / In‐
Boost Cross pressure 2 • Vehicle speed < take Mani‐
Sensor "B" Check >= 7.5 kPa 1 mph fold Temper‐
Circuit ature Sensor
Range/ • Diff. mani‐ 2 - G430- .
Perform‐ fold pres‐ Refer to
ance sure vs. ⇒ “3.6.11 In‐
manifold take Mani‐
pressure 2 fold Temper‐
>= 7.5 kPa ature Sensor
• Or 2 G430 /
Charge Air
• Diff. pres‐ Pressure
sure down‐ Sensor 2
stream G447 ,
throttle vs. Checking”,
manifold page 916 .
pressure 2
>= 7.5 kPa – Check the
charge air
• Diff. baro‐ system for
metric pres‐ proper seal.
sure vs. Refer to En‐
manifold gine Me‐
pressure 2 chanical,
>= 7.5 kPa Fuel Injec‐
tion and Igni‐
• Or tion, Charge
• Diff. baro‐ Air System.
metric pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion MAP 2
to mean val‐
ue (MAP
and BARO)
vs. devia‐
tion pres‐
sure down‐
stream
throttle to
mean value
(MAP and
BARO) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Diff. devia‐
tion MAP 2
to mean val‐
ue (MAP
and pres‐
sure down‐
stream
throttle) vs.
deviation
BARO to
mean value
(MAP and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion MAP 2
to mean val‐
ue (BARO
and pres‐
sure down‐
stream
throttle) vs.
deviation
MAP to
mean value
(BARO and
pressure
down‐
stream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Manifold • Case 1: • Modeled pres‐
Pressure sure quotient
Sensor 2 • Diff. mani‐ (downstream /
Idle fold pres‐ upstream throt‐
Speed: sure vs.
Cross manifold
Check pressure 2
>= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure <
8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐ tle) 0.30 – 0.45
tion MAP 2 [-]
to mean val‐
ue (pres‐
sure down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP 2
to mean val‐
ue (pres‐
sure down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Manifold • Diff. pres‐ • Engine stopped
Pressure sure down‐
Sensor 2 stream
ECM throttle vs.
Keep manifold
Alive pressure 2
Time: >= 7.5 kPa
Cross
Check • Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.5 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐ • Vehicle speed <
tion MAP 2 1 mph
to mean val‐
ue (MAP • ECM keep alive
and BARO) time > 10.0 s
vs. devia‐ • Time after en‐
tion pres‐ gine stop >= 4.0
sure down‐ s
stream
throttle to • Barometric
mean value pressure 55.0 –
(MAP and 110.0 kPa
BARO) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Diff. devia‐
tion MAP 2
to mean val‐
ue (MAP
and pres‐
sure down‐
stream
throttle) vs.
deviation
BARO to
mean value
(MAP and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion MAP 2
to mean val‐
ue (BARO
and pres‐
sure down‐
stream
throttle) vs.
deviation
MAP to
mean value
(BARO and
pressure
down‐
stream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Manifold • Case 1: • Engine running
Pressure
Sensor 2 • Diff. pres‐
Engine sure down‐
Running stream
Non throttle vs.
Charged manifold
Engine: pressure 2
Cross >= 12.0 –
Check 27.0 kPa
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure <
12.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 12.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
12.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐ • Modeled pres‐
tion MAP 2 sure quotient
to mean val‐ (downstream /
ue (pres‐ upstream throt‐
sure down‐ tle) > 0.45; <=
stream 0.80 [-]
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Manifold • Case 1: • Fuel cut off ac‐
Pressure tive
Sensor 2 • Diff. mani‐
Fuel Cut fold pres‐ • Modeled pres‐
Off: sure vs. sure quotient
Cross manifold (downstream /
Check pressure 2 upstream throt‐
>= 8.0 – tle) 0.25 – 0.30
27.0 kPa [-]
• Diff. pres‐ • For time >= 5.0 s
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure <
8.0 – 27.0
kPa
• Or
• Case 2:
• Diff. mani‐
fold pres‐
sure vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure 2
>= 8.0 –
27.0 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
manifold
pressure >=
8.0 – 27.0
kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion MAP 2
to mean val‐
ue (pres‐
sure down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
pressure
down‐
stream
throttle to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
• Diff. devia‐
tion MAP to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP2) vs.
deviation
MAP 2 to
mean value
(pressure
down‐
stream
throttle,
MAP and
MAP 2) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P025B Fuel Sys‐ • Case 1: • Engine speed > • 5.0 s • 2 DCY – Check the
Fuel Pump tem Con‐ 512; <= 8,160 Fuel Delivery
Module trol, Low • Actual and RPM • Continu‐ Unit - GX1- .
Control Pressure adapted I- ous Refer to
Circuit Side Ra‐ part of elec‐ • Electric fuel ⇒ “3.6.23
Range/ tionality tric fuel pump active Fuel Delivery
Perform‐ Check pump con‐ Unit GX1 ,
troller • Time after en‐
ance gine start > 12.0 Checking”,
(PWM sig‐ page 940 .
nal) > s
26.0% • ECT @ cylinder
• Or block 70 – 106°
C
• Actual and
adapted I- • Fuel mass set
part of elec‐ point for low
tric fuel pressure-part
pump con‐ 6.0 – 65.0 mg/
troller rev
(PWM sig‐ • Fuel pressure
nal) < pump not at
-23.0% max. limit
• Case 2:
• Adapted I-
part of elec‐
tric fuel
pump con‐
troller
(PWM sig‐
nal) > n.a.%
• Or
• Adapted I-
part of elec‐
tric fuel
pump con‐
troller
(PWM sig‐
nal) < n.a.
%
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Diff. fuel • Engine speed >
tem Con‐ pressure 512; <= 8,160
trol, Low set point vs. RPM
Pressure actual fuel
Side pressure > • Electric fuel
Function‐ 170.08 kPa pump active
al Check
• Electric fuel • Time after en‐
pump gine start > 12.0
(PWM sig‐ s
nal) > 0.0% • ECT @ cylinder
• For time >= block 70 – 106°
10.0 s C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0261 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 1 Valves tern for active CRK Cylinder 1
Injector Short To short to Fuel Injector
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ - N30- . Refer
Low power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • Injector
driver high
side switch
current driv‐
er stage in‐
ternal value
• And
• Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0262 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 1 Valves tern for active CRK Cylinder 1
Injector Short To short to bat‐ Fuel Injector
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ - N30- . Refer
High Plus power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector • Engine running • 720° CRK
Valves driver volt‐
Short To age > 2.0 V • ECT @ cylinder • Continu‐
Battery block >= -48° C ous
Plus • And
• Engine speed <
(High • Injector 7,000 RPM
Side) driver high
side switch • Injection time >=
current 0 ms
(hardware
values)
driver stage
internal val‐
ue
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0264 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 2 Valves tern for active CRK Cylinder 2
Injector Short To short to Fuel Injector
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ - N31- . Refer
Low power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • Injector
driver high
side switch
current driv‐
er stage in‐
ternal value
• And
• Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0265 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 2 Valves tern for active CRK Cylinder 2
Injector Short To short to bat‐ Fuel Injector
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ - N31- . Refer
High Plus power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0267 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 3 Valves tern for active CRK Cylinder 3
Injector Short To short to Fuel Injector
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ - N32- . Refer
Low power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • Injector
driver high
side switch
current driv‐
er stage in‐
ternal value
• And
• Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0268 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 3 Valves tern for active CRK Cylinder 3
Injector Short To short to bat‐ Fuel Injector
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ - N32- . Refer
High Plus power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0270 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 4 Valves tern for active CRK Cylinder 4
Injector Short To short to Fuel Injector
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ - N33- . Refer
Low power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • Injector
driver high
side switch
current driv‐
er stage in‐
ternal value
• And
• Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0271 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 4 Valves tern for active CRK Cylinder 4
Injector Short To short to bat‐ Fuel Injector
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ - N33- . Refer
High Plus power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0273 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 5 Valves tern for active CRK Cylinder 5
Injector Short To short to Fuel Injector
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ - N83- . Refer
Low power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • Injector
driver high
side switch
current driv‐
er stage in‐
ternal value
• And
• Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0274 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 5 Valves tern for active CRK Cylinder 5
Injector Short To short to bat‐ Fuel Injector
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ - N83- . Refer
High Plus power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0276 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 6 Valves tern for active CRK Cylinder 6
Injector Short To short to Fuel Injector
"A" Circuit Ground ground via • ECT @ cylinder • Continu‐ - N84- . Refer
Low power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage <
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age < 2.0 V
Ground
(Low • And
Side) • Injector
driver high
side switch
current driv‐
er stage in‐
ternal value
• And
• Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
P0277 Injection • Fault pat‐ • Engine stop not • 8,640.0° • 2 DCY – Check the
Cylinder 6 Valves tern for active CRK Cylinder 6
Injector Short To short to bat‐ Fuel Injector
"A" Circuit Battery tery plus via • ECT @ cylinder • Continu‐ - N84- . Refer
High Plus power block >= -48° C ous to
stage diag‐ • Engine speed < ⇒ “3.6.24
nosis detec‐ 7,000 RPM Fuel Injec‐
ted tors, Check‐
• Injection time >= ing”,
• Injector 0.0 s page 942 .
voltage >
2.0 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Injection • Injector
Valves driver volt‐
Short To age > 2.0 V
Battery
Plus (Low • And
Side) • Injector
driver low
side switch
current
(hardware
values)
driver stage
internal val‐
ue
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0299 Super‐ • Diff. set • Engine running • 1.0 s • 2 DCY – Check the
Turbo‐ charger point ratio of Charge Air
charger/ (SC) supercharg‐ • Time after en‐ • Continu‐ Pressure
Super‐ Boost er boost gine start > 10.0 ous Sensor -
charger Control pressure s G31- / Intake
"A" Under‐ rationality and MAP • BARO 63.00 – Manifold
boost Con‐ check upstream 105.00 kPa Temperature
dition high supercharg‐ Sensor -
er vs. meas‐ • Engine speed 0 G72- . Refer
ured ratio of – 8,160 RPM to
supercharg‐ ⇒ “3.6.10
er boost • IAT @ manifold Charge Air
pressure > 5° C Pressure
and MAP Sensor G31 /
• ECT @ cylinder
upstream Intake Mani‐
block > -48° C
supercharg‐ fold Temper‐
er > 0.25 – • Diff. engine ature Sensor
0.35 [-] speed vs. fil‐ G72 , Check‐
tered engine ing”,
• For time >= page 914 .
speed for engine
1.5 s speed dynamic
detection < 96
rpm
• Diff. air mass
setpoint vs. fil‐
tered air mass
setpoint for load
dynamic detec‐
tion < 15.01 mg/
rev
• Fuel cut off not
active
• Pressure gradi‐
ent @ pressure
sensor up‐
stream super‐
charger
-8291.80 –
8291.50 kPa/s
• Gradient super‐
charger boost
pressure
-1,500.00 –
1,500.00 kPa/s
• Fast throttle
adaptation fin‐
ished
• Engine speed >
1504 rpm
• SCB power
stage enabled
• Setpoint ratio of
supercharger
boost pressure
and MAP up‐
stream super‐
charger >= 1.25;
< 2.50 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Measured IAT
@ manifold <=
75° C
• Measured IAT
@ manifold 2 <=
75° C
– Check the
spark plugs
visually.
P0301 Misfire • Catalyst • Initial engine • 200 revo‐ • Immedi‐ – Check the
Cylinder 1 Crank‐ damage speed > 550 lutions ately Cylinder 1
Misfire De‐ shaft misfire RPM Fuel Injector
tected Speed • Continu‐ - N30- . Refer
Fluctua‐ • Catalyst • Engine speed > ous to
tion (Sin‐ damaging 500 RPM ⇒ “3.6.24
gle Or misfire rate Fuel Injec‐
> 0.83 – • Engine speed <
Multiple) 6,820 RPM tors, Check‐
13.89% ing”,
• Time after en‐ page 942 .
gine start > n.a.
s – Check the Ig‐
nition Coil
with Power
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Emission • Engine load > • 1,000 • 2 DCY Output Stage
threshold 4.50 – 41.20 % revolu‐ - N70- . Refer
misfire with‐ tions to
in 1,000 rev • Depending on ⇒ “3.6.29 Ig‐
ECT @ cylinder • Continu‐ nition Coils
• Emission block @ start ous With Power
threshold Output
misfire rate • ECT @ cylinder Stage ,
(MR) > block @ engine
start <= -8° C Checking”,
1.10% page 952 .
• Then activation
• Emission if • 4 x 1,000 • 2 DCY – Check the
threshold revolu‐ spark plugs
misfire with‐ • ECT @ cylinder tions visually.
in 4,000 rev block >= 20° C
• Continu‐ – Check the
• Emission • Or ous Fuel pres‐
threshold • ECT @ cylinder sure regula‐
misfire rate block @ engine tor and resid‐
(MR) > start > -8° C ual pressure
1.10% before high
• And pressure fuel
pumps . Re‐
• Fuel cut off not fer to appro‐
active priate repair
• Or manual.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0302 Misfire • Catalyst • Initial engine • 200 revo‐ • Immedi‐ – Check the
Cylinder 2 Crank‐ damage speed > 550 lutions ately Cylinder 2
Misfire De‐ shaft misfire RPM Fuel Injector
tected Speed • Continu‐ - N31- . Refer
Fluctua‐ • Catalyst • Engine speed > ous to
tion (Sin‐ damaging 500 RPM ⇒ “3.6.24
gle Or misfire rate Fuel Injec‐
> 0.83 – • Engine speed <
Multiple) 6,820 RPM tors, Check‐
13.89 % ing”,
• Time after en‐ page 942 .
• Emission gine start > n.a. • 1,000 • 2 DCY
threshold s revolu‐ – Check the Ig‐
misfire with‐ tions nition Coil 2
in 1,000 rev • Engine load > With Power
4.50 – 41.20 % • Continu‐ Output Stage
• Emission ous - N127- . Re‐
threshold • Depending on fer to
misfire rate ECT @ cylinder ⇒ “3.6.29 Ig‐
(MR) > block @ start nition Coils
1.10% With Power
• ECT @ cylinder
block @ engine Output
start <= -8° C Stage ,
Checking”,
• Then activation page 952 .
if
– Check the
• ECT @ cylinder spark plugs
block >= 20° C visually.
• Or
– Check the
• ECT @ cylinder Fuel pres‐
block @ engine sure regula‐
start > -8° C tor and resid‐
ual pressure
• And before high
• Fuel cut off not pressure fuel
active pumps . Re‐
fer to appro‐
• Or priate repair
manual.
• Single fuel cut
off not active – Check the
pressure in
• Or the fuel sys‐
• Number of fade tem for out of
out cylinders < spec condi‐
3.00 [-] tions before
diagnosing
• And the pressure
sensor. Re‐
• Dynamic mani‐ fer to Fuel
fold air pressure System Me‐
<= n.a. kPa chanical
• Dynamic throttle Testing in
position <= n.a.° ⇒ “3.1 Pre‐
TPS/s liminary
Check”,
• And page 20 .
• Dynamic of en‐
gine load n.a.
• Engine speed
n.a. RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Emission • Dynamic of igni‐ • 4 x 1,000 • 2 DCY
threshold tion angle n.a.° revolu‐
misfire with‐ CRK tions
in 4,000 rev • Or
• Continu‐
• Emission ous
• Dynamic of igni‐
threshold tion angle n.a.°
misfire rate CRK
(MR) >
1.10% • And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0303 Misfire • Catalyst • Initial engine • 200 revo‐ • Immedi‐ – Check the
Cylinder 3 Crank‐ damage speed > 550 lutions ately Cylinder 3
Misfire De‐ shaft misfire RPM Fuel Injector
tected Speed • Continu‐ - N32- . Refer
Fluctua‐ • Catalyst • Engine speed > ous to
tion (Sin‐ damaging 500 RPM ⇒ “3.6.24
gle Or misfire rate Fuel Injec‐
> 0.83 – • Engine speed <
Multiple) 6,820 RPM tors, Check‐
13.89% ing”,
• Time after en‐ page 942 .
• Emission gine start > n.a. • 1,000 • 2 DCY
threshold s revolu‐ – Check the Ig‐
misfire with‐ tions nition Coil
in 1,000 rev • Engine load > with Power
4.50 – 41.20 % • Continu‐ Output Stage
• Emission ous - N291- . Re‐
threshold • Depending on fer to
misfire rate ECT @ cylinder ⇒ “3.6.29 Ig‐
(MR) > block @ start nition Coils
1.10% With Power
• ECT @ cylinder
block @ engine Output
start <= -8° C Stage ,
Checking”,
• Then activation page 952 .
if
– Check the
• ECT @ cylinder spark plugs
block >= 20° C visually.
• Or
– Check the
• ECT @ cylinder Fuel pres‐
block @ engine sure regula‐
start > -8° C tor and resid‐
ual pressure
• And before high
• Fuel cut off not pressure fuel
active pumps . Re‐
fer to appro‐
• Or priate repair
manual.
• Single fuel cut
off not active – Check the
pressure in
• Or the fuel sys‐
• Number of fade tem for out of
out cylinders < spec condi‐
3.00 [-] tions before
diagnosing
• And the pressure
sensor. Re‐
• Dynamic mani‐ fer to Fuel
fold air pressure System Me‐
<= n.a. kPa chanical
• Dynamic throttle Testing in
position <= n.a.° ⇒ “3.1 Pre‐
TPS/s liminary
Check”,
• And page 20 .
• Dynamic of en‐
gine load n.a.
• Engine speed
n.a. RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Emission • Dynamic of igni‐ • 4 x 1,000 • 2 DCY
threshold tion angle n.a.° revolu‐
misfire with‐ CRK tions
in 4,000 rev • Or
• Continu‐
• Emission ous
• Dynamic of igni‐
threshold tion angle n.a.°
misfire rate CRK
(MR) >
1.10% • And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0304 Misfire • Catalyst • Initial engine • 200 revo‐ • Immedi‐ – Check the
Cylinder 4 Crank‐ damage speed > 550 lutions ately Cylinder 4
Misfire De‐ shaft misfire RPM Fuel Injector
tected Speed • Continu‐ - N33- . Refer
Fluctua‐ • Catalyst • Engine speed > ous to
tion (Sin‐ damaging 500 RPM ⇒ “3.6.24
gle Or misfire rate Fuel Injec‐
> 0.83 – • Engine speed <
Multiple) 6,820 RPM tors, Check‐
13.89% ing”,
• Time after en‐ page 942 .
• Emission gine start > n.a. • 1,000 • 2 DCY
threshold s revolu‐ – Check the Ig‐
misfire with‐ tions nition Coil
in 1,000 rev • Engine load > with Power
4.50 – 41.20 % • Continu‐ Output Stage
• Emission ous - N292- . Re‐
threshold • Depending on fer to
misfire rate ECT @ cylinder ⇒ “3.6.29 Ig‐
(MR) > block @ start nition Coils
1.10% With Power
• ECT @ cylinder
block @ engine Output
start <= -8° C Stage ,
Checking”,
• Then activation page 952 .
if
– Check the
• ECT @ cylinder spark plugs
block >= 20° C visually.
• Or
– Check the
• ECT @ cylinder Fuel pres‐
block @ engine sure regula‐
start > -8° C tor and resid‐
ual pressure
• And before high
• Fuel cut off not pressure fuel
active pumps . Re‐
fer to appro‐
• Or priate repair
manual.
• Single fuel cut
off not active – Check the
pressure in
• Or the fuel sys‐
• Number of fade tem for out of
out cylinders < spec condi‐
3.00 [-] tions before
diagnosing
• And the pressure
sensor. Re‐
• Dynamic mani‐ fer to Fuel
fold air pressure System Me‐
<= n.a. kPa chanical
• Dynamic throttle Testing in
position <= n.a.° ⇒ “3.1 Pre‐
TPS/s liminary
Check”,
• And page 20 .
• Dynamic of en‐
gine load n.a.
• Engine speed
n.a. RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Emission • Dynamic of igni‐ • 4 x 1,000 • 2 DCY
threshold tion angle n.a.° revolu‐
misfire with‐ CRK tions
in 4,000 rev • Or
• Continu‐
• Emission ous
• Dynamic of igni‐
threshold tion angle n.a.°
misfire rate CRK
(MR) >
1.10% • And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0305 Misfire • Catalyst • Initial engine • 200 revo‐ • Immedi‐ – Check the
Cylinder 5 Crank‐ damage speed > 550 lutions ately Cylinder 5
Misfire De‐ shaft misfire RPM Fuel Injector
tected Speed • Continu‐ - N83- . Refer
Fluctua‐ • Catalyst • Engine speed > ous to
tion (Sin‐ damaging 500 RPM ⇒ “3.6.24
gle Or misfire rate Fuel Injec‐
> 0.83 – • Engine speed <
Multiple) 6,820 RPM tors, Check‐
13.89% ing”,
• Time after en‐ page 942 .
• Emission gine start > n.a. • 1,000 • 2 DCY
threshold s revolu‐ – Check the Ig‐
misfire with‐ tions nition Coil
in 1,000 rev • Engine load > with Power
4.50 – 41.20 % • Continu‐ Output Stage
• Emission ous - N323- . Re‐
threshold • Depending on fer to
misfire rate ECT @ cylinder ⇒ “3.6.29 Ig‐
(MR) > block @ start nition Coils
1.10% With Power
• ECT @ cylinder
block @ engine Output
start <= -8° C Stage ,
Checking”,
• Then activation page 952 .
if
– Check the
• ECT @ cylinder spark plugs
block >= 20° C visually.
• Or
– Check the
• ECT @ cylinder Fuel pres‐
block @ engine sure regula‐
start > -8° C tor and resid‐
ual pressure
• And before high
• Fuel cut off not pressure fuel
active pumps . Re‐
fer to appro‐
• Or priate repair
manual.
• Single fuel cut
off not active – Check the
pressure in
• Or the fuel sys‐
• Number of fade tem for out of
out cylinders < spec condi‐
3.00 [-] tions before
diagnosing
• And the pressure
sensor. Re‐
• Dynamic mani‐ fer to Fuel
fold air pressure System Me‐
<= n.a. kPa chanical
• Dynamic throttle Testing in
position <= n.a.° ⇒ “3.1 Pre‐
TPS/s liminary
Check”,
• And page 20 .
• Dynamic of en‐
gine load n.a.
• Engine speed
n.a. RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Emission • Dynamic of igni‐ • 4 x 1,000 • 2 DCY
threshold tion angle n.a.° revolu‐
misfire with‐ CRK tions
in 4,000 rev • Or
• Continu‐
• Emission ous
• Dynamic of igni‐
threshold tion angle n.a.°
misfire rate CRK
(MR) >
1.10% • And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0306 Misfire • Catalyst • Initial engine • 200 revo‐ • Immedi‐ – Check the
Cylinder 6 Crank‐ damage speed > 550 lutions ately Cylinder 6
Misfire De‐ shaft misfire RPM Fuel Injector
tected Speed • Continu‐ - N84- . Refer
Fluctua‐ • Catalyst • Engine speed > ous to
tion (Sin‐ damaging 500 RPM ⇒ “3.6.24
gle Or misfire rate Fuel Injec‐
> 0.83 – • Engine speed <
Multiple) 6,820 RPM tors, Check‐
13.89% ing”,
• Time after en‐ page 942 .
• Emission gine start > n.a. • 1,000 • 2 DCY
threshold s revolu‐ – Check the Ig‐
misfire with‐ tions nition Coil
in 1,000 rev • Engine load > with Power
4.50 – 41.20 % • Continu‐ Output Stage
• Emission ous - N324- . Re‐
threshold • Depending on fer to
misfire rate ECT @ cylinder ⇒ “3.6.29 Ig‐
(MR) > block @ start nition Coils
1.10% With Power
• ECT @ cylinder
block @ engine Output
start <= -8° C Stage ,
Checking”,
• Then activation page 952 .
if
– Check the
• ECT @ cylinder spark plugs
block >= 20° C visually.
• Or
– Check the
• ECT @ cylinder Fuel pres‐
block @ engine sure regula‐
start > -8° C tor and resid‐
ual pressure
• And before high
• Fuel cut off not pressure fuel
active pumps . Re‐
fer to appro‐
• Or priate repair
manual.
• Single fuel cut
off not active – Check the
pressure in
• Or the fuel sys‐
• Number of fade tem for out of
out cylinders < spec condi‐
3.00 [-] tions before
diagnosing
• And the pressure
sensor. Re‐
• Dynamic mani‐ fer to Fuel
fold air pressure System Me‐
<= n.a. kPa chanical
• Dynamic throttle Testing in
position <= n.a.° ⇒ “3.1 Pre‐
TPS/s liminary
Check”,
• And page 20 .
• Dynamic of en‐
gine load n.a.
• Engine speed
n.a. RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Emission • Dynamic of igni‐ • 4 x 1,000 • 2 DCY
threshold tion angle n.a.° revolu‐
misfire with‐ CRK tions
in 4,000 rev • Or
• Continu‐
• Emission ous
• Dynamic of igni‐
threshold tion angle n.a.°
misfire rate CRK
(MR) >
1.10% • And
• Rough road not
detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0326 Knock • Difference • ECT @ cylinder • 4.3 s • 2 DCY – Check the
Knock/ Sensor between block > 65° C Knock Sen‐
Combus‐ Rationali‐ knock sen‐ • Continu‐ sor 1 - G61- .
tion Vibra‐ ty Check sor signal • MAF > 354.0 ous Refer to
tion Sen‐ Low and aver‐ mg/rev ⇒ “3.6.34
sor 1 Cir‐ age knock Knock Sen‐
cuit sensor sig‐ sor 1 G61 ,
Range/ nal < 0.00 – Checking”,
Perform‐ 0.14 V page 962 .
ance Bank
1 or Single
Sensor
P0327 Knock • Sensor sig‐ • ECT @ cylinder • 4.0 s • 2 DCY – Check the
Knock/ Sensor nal < 0.12 – block > 65° C Knock Sen‐
Combus‐ Out Of 0.27 V • Continu‐ sor 1 - G61- .
tion Vibra‐ Range • MAF > 354.0 ous Refer to
tion Sen‐ mg/rev ⇒ “3.6.34
sor 1 Cir‐ • Engine speed > Knock Sen‐
cuit Low 1,760 RPM sor 1 G61 ,
Bank 1 or Checking”,
Single page 962 .
Sensor
P0331 Knock • Difference • ECT @ cylinder • 4.3 s • 2 DCY – Check the
Knock/ Sensor 2 between block > 65° C Knock Sen‐
Combus‐ Rationali‐ knock sen‐ • Continu‐ sor 2 - G66- .
tion Vibra‐ ty Check sor signal • MAF > 354.0 ous Refer to
tion Sen‐ Low and aver‐ mg/rev ⇒ “3.6.35
sor 2 Cir‐ age knock Knock Sen‐
cuit sensor sig‐ sor 2 G66 ,
Range/ nal < 0.00 – Checking”,
Perform‐ 0.14 V page 964 .
ance Bank
2
P0332 Knock • Sensor sig‐ • ECT @ cylinder • 4.0 s • 2 DCY – Check the
Knock/ Sensor 2 nal < 0.12 – block > 65° C Knock Sen‐
Combus‐ Out Of 0.27 V • Continu‐ sor 2 - G66- .
tion Vibra‐ Range • MAF > 354.0 ous Refer to
tion Sen‐ mg/rev ⇒ “3.6.35
sor 2 Cir‐ • Engine speed > Knock Sen‐
cuit Low 1,760 RPM sor 2 G66 ,
Bank 2 Checking”,
page 964 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0335 Crank‐ • Counted • Signal edges @ • 0.01 s • 2 DCY – Check the
Crank‐ shaft Po‐ exhaust selected cam‐ Engine
shaft Posi‐ sition camshaft shaft signal de‐ • Continu‐ Speed Sen‐
tion Sen‐ Sensor signals tected ous sor - G28- .
sor "A" Cir‐ Activity without syn‐ Refer to
cuit Check chroniza‐ • Choice of: ⇒ “3.6.18
tion >= 17.0 • Ignition off Engine
[-] Speed Sen‐
• Engine speed > sor G28 ,
• Or 192 RPM Checking”,
• Counted in‐ • page 930 .
Engine stalling
take cam‐ >= 1.0 s
shaft sig‐
nals without • Or
synchroni‐
zation >= • Synchronization
17.0 [-] test incorrect
• Or
• Engine speed
>= 192 RPM
• Or
• Engine running
• Engine stalling
>= 5.0 s
• Or
• Backwards rota‐
tion not detected
• Or
• Engine speed
>= 400 RPM
• Engine stop ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0336 Engine • Segment • Fuel cut off ac‐ • 120.0° • 2 DCY – Check the
Crank‐ Speed adaptation tive CRK Engine
shaft Posi‐ Sensor >= 0.70 % Speed Sen‐
tion Sen‐ Out Of • Delay time >= • Continu‐ sor - G28- .
sor "A" Cir‐ Range 1,440.0° CRK ous Refer to
cuit • And ⇒ “3.6.18
Range/ Engine
Perform‐ • Diff. actual air Speed Sen‐
ance mass vs. previ‐ sor G28 ,
ous air mass <= Checking”,
20.01 – 39.99 page 930 .
mg/rev
• Engine load <=
20.0 %
• Dynamic throttle
position <=
269.50 –
398.40° TPS/s
• Rough road not
detected
• Engine rough‐
ness signal not
valid
• Segments in fuel
cut-off mode >=
12.00 [-]
• Segment adap‐
tation finished
• Diff. between
adapted value of
cylinder 1 and
cylinder 6 < 0.50
%
• Diff. Between
adapted value of
cylinder 4 and
cylinder 2 < 0.50
%
• Diff. between
adapted value of
cylinder 3 and
cylinder 5 < 0.50
%
• Engine speed
2,016 – 5,024
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Crank‐ • Case 1: • Engine speed • 45,720.0°
shaft Po‐ >= 400 RPM CRK
sition • Engine
Sensor speed > • Continu‐
Rationali‐ 3,000 RPM ous
ty Check • Time be‐
tween fall‐
ing signal
edges 0 –
50 μs
• Case 2:
• Engine
speed <=
3,000 RPM
• Time be‐
tween sig‐
nal edges <
30 μs
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Crankshaft • General condi‐ • 2,160.0°
reference tions: CRK
gap not de‐
tected • Reference gap • Continu‐
of reluctor wheel ous
detected
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Counted • General condi‐ • 1,800.0°
teeth vs. tions: CRK
reference
>= 1 – <= 2 • Engine speed > • Continu‐
[-] 320 RPM ous
• And
• Case 1:
• Ignition off
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0339 Crank‐ • Crankshaft • General condi‐ • 3.0 (con‐ • 2 DCY – Check the
Crank‐ shaft Po‐ reference tions: secutive Engine
shaft Posi‐ sition gap not de‐ start/stop Speed Sen‐
tion Sen‐ Sensor tected • Reference gap cycle) sor - G28- .
sor "A" Cir‐ Rationali‐ of reluctor wheel Refer to
cuit Inter‐ ty Check not detected ⇒ “3.6.18
mittent • And Engine
Speed Sen‐
• Case 1: sor G28 ,
Checking”,
• Ignition off page 930 .
• Engine speed >
192 RPM
• Engine stalling
>= 1.0 s
• Or
• Case 2:
• Engine speed
>= 192 RPM
• Or
• Engine running
• And
• Engine stalling
>= 5.0 s
• Or
• Case 3:
• Backwards rota‐
tion not detected
• Or
• Case 4:
• Engine speed
>= 400 RPM
• Engine stopped
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0341 Camshaft • Ratio be‐ • Engine speed • 360.0° • 2 DCY – Check the
Camshaft Position tween 400 – 8,160 CRK Camshaft
Position Sensor measured RPM Position
Sensor "A" Intake segment • Continu‐ Sensor -
Circuit Rationali‐ time ratio ous G40- . Refer
Range/ ty Check and speci‐ to
Perform‐ fied cam‐ ⇒ “3.6.4
ance Bank shaft angle Camshaft
1 or Single ratio > 2.75 Position
Sensor [-] Sensor G40 ,
Checking”,
• Or page 901 .
• Ratio be‐
tween
measured
segment
time ratio
and speci‐
fied cam‐
shaft angle
ratio < 0.36
[-]
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
< -70.0°
CRK
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
> 19.0°
CRK
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0346 Camshaft • Ratio be‐ • Engine speed • 360.0° • 2 DCY – Check the
Camshaft Position tween 400 – 8,160 CRK Camshaft
Position Sensor measured RPM Position
Sensor "A" Intake 2 segment • Continu‐ Sensor 2 -
Circuit Rationali‐ time ratio ous G163- . Re‐
Range/ ty Check and speci‐ fer to
Perform‐ fied cam‐ ⇒ “3.6.5
ance Bank shaft angle Camshaft
2 ratio > 2.75 Position
[-] Sensor 2
G163 ,
• Or Checking”,
• Ratio be‐ page 903 .
tween
measured
segment
time ratio
and speci‐
fied cam‐
shaft angle
ratio < 0.36
[-]
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
< -70.0°
CRK
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
> 19.0°
CRK
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Camshaft • Offset be‐ • Engine synchro‐ • 450.0°
Position tween cam‐ nization via CRK
2 / Crank‐ shaft and crankshaft and
shaft Po‐ crankshaft camshaft not fin‐ • Once /
sition In‐ < -70.0° ished DCY
take - Out CRK
Of Range • or
• Or
• Engine synchro‐
• Offset be‐ nization via
tween cam‐ crankshaft and
shaft and camshaft lost
crankshaft
> 19.0° • and
CRK • Failure by ex‐
haust camshaft
sensor detected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0366 Camshaft • Ratio be‐ • Engine speed • 360.0° • 2 DCY – Check the
Camshaft Position tween 400 – 8,160 CRK Camshaft
Position Sensor measured RPM Position
Sensor "B" Exhaust segment • Continu‐ Sensor 3 -
Circuit Rationali‐ time ratio ous G300- . Re‐
Range/ ty Check and speci‐ fer to
Perform‐ fied cam‐ ⇒ “3.6.6
ance Bank shaft angle Camshaft
1 ratio > 2.75 Position
[-] Sensor 3
G300 ,
• Or Checking”,
• Ratio be‐ page 905 .
tween
measured
segment
time ratio
and speci‐
fied cam‐
shaft angle
ratio < 0.36
[-]
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
< -19.0°
CRK
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
> 60.0°
CRK
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0391 Camshaft • Segment • Engine speed • 1,440.0° • 2 DCY – Check the
Camshaft Position time value < 400 – 8,160 CRK Camshaft
Position Sensor 50 μs RPM Position
Sensor "B" Exhaust • Continu‐ Sensor 4 -
Circuit 2 Signal ous G301- . Re‐
Range/ Activity fer to
Perform‐ Check • No change • Engine speed • 1,080.0° ⇒ “3.6.7
ance Bank on signal >= >= 400 RPM CRK Camshaft
2 3 [-] Position
• Continu‐ Sensor 4
ous G301 ,
Checking”,
Camshaft • Ratio be‐ • Engine speed • 360.0° page 908 .
Position tween 400 – 8,160 CRK
Sensor measured RPM
Exhaust segment • Continu‐
2 Ration‐ time ratio ous
ality and speci‐
Check fied cam‐
shaft angle
ratio > 2.75
[-]
• Or
• Ratio be‐
tween
measured
segment
time ratio
and speci‐
fied cam‐
shaft angle
ratio < 0.36
[-]
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
< -19.0°
CRK
• Or
• Offset be‐
tween cam‐
shaft and
crankshaft
> 60.0°
CRK
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Camshaft • Offset be‐ • Engine synchro‐ • 450.0°
Position tween cam‐ nization via CRK
2 / Crank‐ shaft and crankshaft and
shaft Po‐ crankshaft camshaft not fin‐ • Once /
sition Ex‐ < -19.0° ished DCY
haust - CRK
Correla‐ • Or
tion Out • Or
• Engine synchro‐
Of Range • Offset be‐ nization via
tween cam‐ crankshaft and
shaft and camshaft lost
crankshaft
> 60.0°
CRK
P0413 Secon‐ • Output volt‐ • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air age, lower Secondary
tem Valve range >= • Actuator com‐ • Continu‐ Air Injection
Switching Open Cir‐ 1.92 – 2.21 manded off ous Solenoid
Valve "A" cuit V Valve -
Circuit N112- . Refer
Open • Output volt‐ to
age, upper ⇒ “3.6.43
range Secondary
(hardware Air Injection
values) <= Solenoid
2.85 – 3.25 Valve N112 ,
V Checking”,
page 984 .
P0414 Secon‐ • Output volt‐ • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air age (hard‐ Secondary
tem Valve ware val‐ • Actuator com‐ • Continu‐ Air Injection
Switching Short To ues) < 1.92 manded off ous Solenoid
Valve "A" Ground – 2.21 V Valve -
Circuit N112- . Refer
Shorted Secon‐ • Actuator • Engine running to
dary Air tempera‐ ⇒ “3.6.43
Valve ture > 160 – • Actuator com‐ Secondary
Short To 200° C manded on Air Injection
Battery Solenoid
Plus • Or Valve N112 ,
Checking”,
• Output cur‐ page 984 .
rent (hard‐
ware val‐
ues) driver
stage inter‐
nal value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0418 Secon‐ • Output volt‐ • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air age, lower Secondary
tem Con‐ Injection range 1.92 • Actuator com‐ • Continu‐ Air Injection
trol "A" Cir‐ Pump – 2.21 V manded off ous Pump Relay
cuit Relay - -J299-- /
Open Cir‐ • Output volt‐ Secondary
cuit age, upper Air Injection
range Pump Motor
(hardware - V101- . Re‐
values) <= fer to
2.85 – 3.25 ⇒ “3.6.42
V Secondary
Air Injection
Pump Relay
J299 / Sec‐
ondary Air In‐
jection Pump
Motor V101 ,
Checking”,
page 982 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0420 Catalyst • Catalyst ef‐ • General condi‐ • 60.0 – • 2 DCY – Check the
Catalyst System ficiency > tions: 70.0 s Oxygen Sen‐
System Ef‐ NMOG / 1.79 [-] sor 1 Before
ficiency NMHC • Vehicle speed • Once / Catalytic
Below Conver‐ >= 19 mph DCY Converter -
Threshold sion Ca‐ • BARO >= 63.0 GX10- . Re‐
Bank 1 pability kPa fer to
⇒ “3.6.39
• Catalyst over‐ Oxygen Sen‐
heating protec‐ sor 1 Before
tion not active Catalytic
Converter
• Turbine over‐ GX10 ,
heating protec‐ Checking”,
tion not equip‐ page 972 .
ped
– Check the
• O2S rear ready Oxygen Sen‐
• O2S front ready sor 1 After
Catalytic
• ECT @ cylinder Converter -
block > 70° C GX7- . Refer
to
• IAT @ manifold ⇒ “3.6.38
> -48° C Oxygen Sen‐
• Modeled cata‐ sor 1 After
lyst temperature Catalytic
@ start of diag‐ Converter
nosis > 500° C GX7 , Check‐
ing”,
• Modeled cata‐ page 970 .
lyst temperature
@ during diag‐ – Check the
nosis 460 – 990° Three Way
C Catalytic
Converter
• Diff. between (TWC). Re‐
dynamic and fer to
stationary cata‐ ⇒ “3.6.44
lyst temperature Three Way
-292 – 292° C Catalytic
• Integrated air Converter
mass, catalyst (TWC),
temp. conditions Checking”,
fulfilled >= 25.0 – page 986 .
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.0 mg/rev
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted %
• Coasting func‐
tion n.a.
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve ( closing
time ) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 2.20 -
2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0430 Catalyst • Catalyst ef‐ • General condi‐ • 60.0 – • 2 DCY – Check the
Catalyst System ficiency > tions: 70.0 s Oxygen Sen‐
System Ef‐ NMOG / 1.79 [-] sor 2 Before
ficiency NMHC • Vehicle speed • Once / Catalytic
Below Conver‐ >= 19 mph DCY Converter -
Threshold sion Ca‐ • BARO >= 63.0 GX11- . Re‐
Bank 2 pability kPa fer to
⇒ “3.6.41
• Catalyst over‐ Oxygen Sen‐
heating protec‐ sor 2 Before
tion not active Catalytic
Converter
• Turbine over‐ GX11 ,
heating protec‐ Checking”,
tion not equip‐ page 978 .
ped
– Check the
• O2S rear ready Oxygen Sen‐
• O2S front ready sor 2 After
Catalytic
• ECT @ cylinder Converter -
block > 70° C GX8- . Refer
to
• IAT @ manifold ⇒ “3.6.40
> -48° C Oxygen Sen‐
• Modeled cata‐ sor 2 After
lyst temperature Catalytic
@ start of diag‐ Converter
nosis > 500° C GX8 , Check‐
ing”,
• Modeled cata‐ page 976 .
lyst temperature
@ during diag‐ – Check the
nosis 460 – 990° Three Way
C Catalytic
Converter
• Diff. between (TWC). Re‐
dynamic and fer to
stationary cata‐ ⇒ “3.6.44
lyst temperature Three Way
-292 – 292° C Catalytic
• Integrated air Converter
mass, catalyst (TWC),
temp. conditions Checking”,
fulfilled >= 25.0 – page 986 .
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• Air mass , lower
range >= 70.01 –
120.01 mg/rev
• Air mass , upper
range <= 460.01
– 560.0 mg/rev
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Dynamic air
mass < 60.0 mg/
rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated air
mass after dy‐
namic condi‐
tions are fulfilled
> 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated air
mass >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted %
• Coasting func‐
tion n.a.
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve ( closing
time ) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge
valve n.a.
• And
• Modeled air
mass integral >
0.0 g
• Integrated air
mass per cylin‐
der >= 2.02 -
2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0441 EVAP • Ratio actual • ECT @ cylinder • 8.5 s • 2 DCY – Check the
EVAP Purge intake block > 60° C EVAP Canis‐
System In‐ Valve manifold • Once / ter Purge
correct Function‐ pressure • BARO > 73.0 DCY Regulator
Purge al Check: and mod‐ kPa Valve 1 -
Flow Stuck eled set • AAT > 4° C N80- . Refer
Close point intake to
manifold • AAT @ start >= ⇒ “3.6.20
pressure < 5° C EVAP Canis‐
0.05 [-] ter Purge
• Diff. barometric Regulator
pressure vs. fil‐ Valve 1 N80 ,
tered intake Checking”,
manifold pres‐ page 934 .
sure > n.a. kPa
– Check the
• Diff. barometric EVAP Sys‐
pressure vs. fil‐ tem for
tered intake Leaks. Refer
manifold pres‐ to
sure > 25.0 kPa ⇒
• Ratio MAF @ “2.2.4 EVAP
manifold and System,
MAF max > 0.15 Checking for
[-] Leaks”,
page 11 .
• Engine speed
1,050 – 2,500
RPM
• Vehicle speed
>= 3 mph
• Diff. engine
speed vs. fil‐
tered engine
speed < 90 RPM
• Diff. ratio MAF
@ manifold and
MAF max vs. ra‐
tio filtered MAF
@ manifold and
MAF max < 0.15
[-]
• Diff. modeled
MAP vs. filtered
modeled MAP <
1.20 kPa
• Integrated air
mass since en‐
gine start >=
5,000.0 –
7,500.0 g
• And lambda
conditions fulfil‐
led
• Lambda control
active
• Lambda control
value -30.0 –
30.0 %
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• O2S front 0.90 –
1.10 [-]
• Fuel cut off n.a
• And
• Case 1:
• Integrated air
mass @ canister
purge valve per
driving cycle >=
n.a. g
• Case 2:
• Ratio MAF @
canister purge
and MAF per
cylinder >= 0.0
[-]
• Or
• Canister purge
sampling rate >=
40.0 %
• And
• Integrated air
mass @ canister
purge valve >=
7.1 g
• And
• Depending on
AAT:
• AAT >= 50° C
• Canister load <=
0.20 [-]
• Or
• AAT >= 30; <
50° C
• Canister load <=
0.20 [-]
• Or
• AAT < 30° C
• Canister load <=
0.20 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0444 EVAP • Output volt‐ • Engine start not • 2.0 s • 2 DCY – Check the
EVAP Purge age, lower active EVAP Canis‐
System Valve range >= • Continu‐ ter Purge
Purge Open Cir‐ 1.92 – 2.21 • Engine running ous Regulator
Control cuit V • Evap purge Valve 1 -
Valve "A" valve opening N80- . Refer
Circuit • Output volt‐ to
age, upper signal (PWM) >
Open 3.13; <= 98.83 ⇒ “3.6.20
range EVAP Canis‐
(hardware %
ter Purge
values) <= • Actuator com‐ Regulator
2.85 – 3.25 manded off Valve 1 N80 ,
V Checking”,
page 934 .
P0445 EVAP • Output volt‐ • Engine start not • 2.0 s • 2 DCY – Check the
EVAP Purge age (hard‐ active EVAP Canis‐
System Valve ware val‐ • Continu‐ ter Purge
Purge Short To ues) 1.92 – • Engine running ous Regulator
Control Ground 2.21 V • Evap purge Valve 1 -
Valve "A" valve opening N80- . Refer
Circuit signal (PWM) <= to
Shorted 98.83 % ⇒ “3.6.20
EVAP Canis‐
• Actuator com‐ ter Purge
manded off Regulator
Valve 1 N80 ,
EVAP • Actuator • Engine start not Checking”,
Purge tempera‐ active page 934 .
Valve ture 160 –
Short To 200° C • Engine running
Battery • Evap purge
Plus • Or
valve opening
• Output cur‐ signal (PWM) >=
rent (hard‐ 3.13 %
ware val‐
ues) driver • Actuator com‐
stage inter‐ manded on
nal value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0450 Smart • Signal volt‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Tempera‐ age 0.39 – EVAP Canis‐
System ture Sen‐ 0.55 V • Engine running • Continu‐ ter Purge
Pressure sor Open ous Regulator
• Case 2:
Sensor/ Circuit Valve 1 -
Switch Cir‐ • Ignition off N80- . Refer
cuit to
• NVLD (EVAP ⇒ “3.6.20
system) diag‐ EVAP Canis‐
nostic mode ac‐ ter Purge
tive Regulator
Valve 1 N80 ,
Checking”,
page 934 .
– Check the
Fuel Tank
Leak Detec‐
tion Control
Module -
J909- . Refer
to
⇒ “3.6.28
Fuel Tank
Leak Detec‐
tion Control
Module
J909 ,
Checking”,
page 950 .
– Check the
EVAP Sys‐
tem for
Leaks. Refer
to
⇒
“2.2.4 EVAP
System,
Checking for
Leaks”,
page 11 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0451 NVLD • Natural vac‐ • Ignition off • 35.0 s • 2 DCY – Check the
EVAP Switch uum leak EVAP Canis‐
System Function‐ detection • Fuel level < • Once / ter Purge
Pressure al Check: (NVLD) 85.10% DCY Regulator
Sensor/ Stuck switch posi‐ • Fuel tempera‐ Valve 1 -
Switch Cir‐ Close tion closed ture increase >= N80- . Refer
cuit 5K to
Range/ ⇒ “3.6.20
Perform‐ • For time >= 1.0 h EVAP Canis‐
ance ter Purge
• AAT >= 4° C Regulator
Valve 1 N80 ,
• Barometric Checking”,
pressure > page 934 .
73.00 kPa
• Time since igni‐ – Check the
tion off > 20; < EVAP Sys‐
1,440 min tem for
Leaks. Refer
to
⇒
“2.2.4 EVAP
System,
Checking for
Leaks”,
page 11 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0452 Smart • Signal volt‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Tempera‐ age < 0.24 EVAP Canis‐
System ture Sen‐ V • Engine running • Continu‐ ter Purge
Pressure sor Short ous Regulator
• Case 2:
Sensor/ To Valve 1 -
Switch Cir‐ Ground • Ignition off N80- . Refer
cuit Low to
• NVLD (EVAP ⇒ “3.6.20
system) diag‐ EVAP Canis‐
nostic mode ac‐ ter Purge
tive Regulator
Valve 1 N80 ,
Checking”,
page 934 .
– Check the
Fuel Tank
Leak Detec‐
tion Control
Module -
J909- . Refer
to
⇒ “3.6.28
Fuel Tank
Leak Detec‐
tion Control
Module
J909 ,
Checking”,
page 950 .
– Check the
EVAP Sys‐
tem for
Leaks. Refer
to
⇒
“2.2.4 EVAP
System,
Checking for
Leaks”,
page 11 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0453 Smart • Signal volt‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Tempera‐ age > 3.0 V EVAP Canis‐
System ture Sen‐ • Engine running • Continu‐ ter Purge
Pressure sor Short ous Regulator
• Case 2:
Sensor/ To Bat‐ Valve 1 -
Switch Cir‐ tery Plus • Ignition off N80- . Refer
cuit High to
• NVLD (EVAP ⇒ “3.6.20
system) diag‐ EVAP Canis‐
nostic mode ac‐ ter Purge
tive Regulator
Valve 1 N80 ,
Checking”,
page 934 .
– Check the
Fuel Tank
Leak Detec‐
tion Control
Module -
J909- . Refer
to
⇒ “3.6.28
Fuel Tank
Leak Detec‐
tion Control
Module
J909 ,
Checking”,
page 950 .
– Check the
EVAP Sys‐
tem for
Leaks. Refer
to
⇒
“2.2.4 EVAP
System,
Checking for
Leaks”,
page 11 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0456 EVAP • Natural vac‐ • Ignition off • 0.1 s • 2 DCY – Check the
EVAP System uum leak EVAP Canis‐
System Small detection • Fuel level < • Once / ter Purge
Leak De‐ Leak (NVLD) 85.10% DCY Regulator
tected Function‐ switch posi‐ • Fuel tempera‐ Valve 1 -
(Very al Check tion open ture drop >= 6 K N80- . Refer
Small to
Leak) • For time > 1.0 h ⇒ “3.6.20
EVAP Canis‐
• AAT >= 4° C ter Purge
Regulator
• Barometric Valve 1 N80 ,
pressure > Checking”,
73.00 kPa page 934 .
• Diff. barometric
pressure @ stop – Check the
and barometric EVAP Sys‐
pressure @ start tem for
< 0.65 kPa Leaks. Refer
to
• Time since igni‐ ⇒
tion off > 90; < “2.2.4 EVAP
600 min System,
Checking for
Leaks”,
page 11 .
P0461 Fuel Lev‐ • Diff. fuel • General: • 1.0 s • 2 DCY – Refer to ap‐
Fuel Level el Plausi‐ consump‐ propriate wir‐
Sensor "A" bility tion and fuel • Refueling or de- • Continu‐ ing diagram.
Circuit Check level fueling not de‐ ous If fuel level
Range/ changes < tected sensor and
Perform‐ -70.00; > • And circuitry are
ance 12.00 ok, then re‐
• Case 1: For tank place the in‐
full strument
cluster. Re‐
• Fuel level >= fer to appro‐
96.09 % priate repair
manual.
• Fuel consump‐
tion since last re‐
fueling or last
plausibility
check > 44.0
• Case 2: for tank
not full
• Fuel level <=
96.09 %
• Fuel consump‐
tion since last re‐
fueling or last
plausibility
check > 15.0
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Cluster • Instrument cluster. Re‐
Module cluster fer to appro‐
module sig‐ priate repair
nal: signal manual.
range
check fail‐
ure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0491 Secon‐ • Case 1: • ECT @ cylinder • 0.2 s • 2 DCY – Check the
AIR Sys‐ dary Air block @ engine Secondary
tem Insuf‐ System • Deviation start 5 – 50° C • Once / Air Injection
ficient Flow lambda DCY Pump Relay
Flow Bank Check controller • AAT @ engine - J299- / Sec‐
1 During output > start >= 5° C ondary Air In‐
Catalyst n.a. % jection Pump
• Time after en‐
Heating • Relative gine start >= Motor - -
diff. mod‐ 22.0 – 120.0 s V101-- . Re‐
eled secon‐ fer to
dary mass • Fuel cut off not ⇒ “3.6.42
air flow vs. active Secondary
actual sec‐ • Air Injection
O2S front ready Pump Relay
ondary
mass air J299 / Sec‐
• MAF <=
flow > n.a. ondary Air In‐
2,047.97 kg/h
[-] jection Pump
• Air mass (en‐ Motor V101 ,
• For time >= gine load), lower Checking”,
n.a. s range >= 0.0 – page 982 .
82.0 mg/rev
• Or – Check the
• Air mass (en‐ Combination
• Case 2: gine load), up‐ valve for sec‐
• Ratio mod‐ per range <= ondary air in‐
eled secon‐ 452.0 mg/rev jection. Refer
dary mass • to appropri‐
Engine speed, ate repair
air flow and lower range >=
measured manual.
800 – 8,160
secondary RPM
mass air
flow < 30.0 • Engine speed,
% upper range <=
3,008 RPM
• Additional mass
fuel flow for wall
fuel liquid film
-6.0 – 6.0 mg/rev
• O2S front > 2.0
[-]
• Modeled pres‐
sure quotient <=
1.0 [-]
• AIR system
commanded on
• Low dynamic
conditions
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 220
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 110.0 mg/
rev
• Diff. lambda vs.
averaged lamb‐
da for lambda
dynamic detec‐
tion < 1.10 [-]
• Integrated MAF
> 10.0 g
• Catalyst heating
active
• Secondary air
injection active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0492 Secon‐ • Case 1: • ECT @ cylinder • 0.2 s • 2 DCY – Check the
AIR Sys‐ dary Air block @ engine Secondary
tem Insuf‐ System 2 • Deviation start 5 – 50° C • Once / Air Injection
ficient Flow lambda DCY Pump Relay
Flow Bank Check controller • AAT @ engine - J299- / Sec‐
2 During output > start >= 5° C ondary Air In‐
Catalyst n.a. % jection Pump
• Time after en‐
Heating • Relative gine start >= Motor - -
diff. mod‐ 22.0 – 120.0 s V101-- . Re‐
eled secon‐ fer to
dary mass • Fuel cut off not ⇒ “3.6.42
air flow vs. active Secondary
actual sec‐ • Air Injection
O2S front ready Pump Relay
ondary
mass air J299 / Sec‐
• MAF <=
flow > n.a. ondary Air In‐
2,047.97 kg/h
[-] jection Pump
• Air mass (en‐ Motor V101 ,
• For time >= gine load), lower Checking”,
n.a. s range >= 0.0 – page 982 .
82.0 mg/rev
• Or – Check the
• Air mass (en‐ Combination
• Case 2: gine load), up‐ valve for sec‐
• Ratio mod‐ per range <= ondary air in‐
eled secon‐ 452.0 mg/rev jection. Refer
dary mass • to appropri‐
Engine speed, ate repair
air flow and lower range >=
measured manual.
800 – 8,160
secondary RPM
mass air
flow < 30.0 • Engine speed,
% upper range <=
3,008 RPM
• Additional mass
fuel flow for wall
fuel liquid film
-6.0 – 6.0 mg/rev
• O2S front > 2.00
[-]
• Modeled pres‐
sure quotient <=
1.00 [-]
• AIR system
commanded on
• Low dynamic
conditions
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 220
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 110.0 mg/
rev
• Diff. lambda vs.
averaged lamb‐
da for lambda
dynamic detec‐
tion < 1.10 [-]
• Integrated MAF
> 10.0 g
• Catalyst heating
active
• Secondary air
injection active
• Speed sen‐
sor fault val‐
ue: Ration‐
ality check
high failure
• Speed sen‐
sor fault val‐
ue: Ration‐
ality check
low failure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0506 Idle Con‐ • Diff. actual • General condi‐ • 7.0 s • 2 DCY – Check the
Idle Con‐ troller engine tions: Throttle
trol Sys‐ Function speed vs. • Continu‐ Valve Con‐
tem RPM - Monitor‐ engine • Vehicle speed = ous trol Module -
Lower ing: En‐ speed set 0 mph GX3- . Refer
Than Ex‐ gine point < 100 • Accelerator ped‐ to
pected Speed RPM al released by ⇒ “3.6.45
Deviation driver Throttle
• Integrated I- Valve Con‐
part of idle • Throttle actuator trol Module
speed con‐ commanded on GX3 , Check‐
troller n.a. ing”,
• Evap purge flow page 987 .
< 4.0 kg/h
• Engine running
• Time after en‐
gine start > 5.0 –
25.4 s
• Clutch switch
n.a.
• Barometric
pressure > 63.0
kPa
• Catalyst heating
not active
• ECT @ cylinder
block > -9° C
• And
• Set point
change < n.a.
RPM
• For time >= n.a.
s
• And
• Additional after
dynamic condi‐
tions fulfilled:
• Gear switch not
active (automat‐
ic transmission
only)
• Accelerator ped‐
al released by
driver
• Vehicle speed 0
mph
• Engine load <
100.0 % (man‐
ual transmission
only)
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0507 Idle Con‐ • Diff. actual • General condi‐ • 7.0 s • 2 DCY – Check the
Idle Con‐ troller engine tions: Throttle
trol Sys‐ Function speed vs. • Continu‐ Valve Con‐
tem RPM - Monitor‐ engine • Vehicle speed = ous trol Module -
Higher ing: En‐ speed set 0 mph GX3- . Refer
Than Ex‐ gine point > 100 • Accelerator ped‐ to
pected Speed RPM al released by ⇒ “3.6.45
Deviation driver Throttle
• Integrated I- Valve Con‐
part of idle • Throttle actuator trol Module
speed con‐ commanded on GX3 , Check‐
troller n.a. ing”,
• Evap purge flow page 987 .
< 4.0 kg/h
• Engine running
• Time after en‐
gine start > 5.0 –
25.4 s
• Clutch switch
n.a.
• Barometric
pressure > 63.0
kPa
• Catalyst heating
not active
• ECT @ cylinder
block > -9° C
• And
• Set point
change < n.a.
RPM
• For time >= n.a.
s
• And
• Additional after
dynamic condi‐
tions fulfilled:
• Gear switch not
active (automat‐
ic transmission
only)
• Accelerator ped‐
al released by
driver
• Vehicle speed 0
mph
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P050A Cold • Diff. actual • General condi‐ • 7.0 s • 2 DCY – Check the
Cold Start Start engine tions: Throttle
Idle Con‐ Monitor‐ speed vs. • Continu‐ Valve Con‐
trol Sys‐ ing Idle engine • Vehicle speed = ous trol Module -
tem Per‐ Controller speed set 0 mph GX3- . Refer
formance Function point > 200 • Accelerator ped‐ to
Monitor‐ RPM al released by ⇒ “3.6.45
ing: En‐ driver Throttle
gine • Integrated I- Valve Con‐
Speed part of idle • Throttle actuator trol Module
Deviation speed con‐ commanded on GX3 , Check‐
troller n.a. ing”,
• Evap purge flow page 987 .
< 4.0 kg/h
• Engine running
• Time after en‐
gine start > 5.0 –
25.4 s
• Clutch switch
n.a.
• Barometric
pressure > 63.0
kPa
• Catalyst heating
active
• ECT @ cylinder
block > -9° C
• And
• Set point
change < n.a.
RPM
• For time >= n.a.
s
• And
• Additional after
dynamic condi‐
tions fulfilled:
• Gear switch not
active (automat‐
ic transmission
only)
• Accelerator ped‐
al released by
driver
• Vehicle speed 0
mph
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. actual • General condi‐
engine tions:
speed vs.
engine • Vehicle speed =
speed set 0 mph
point < -100 • Accelerator ped‐
– -150 RPM al released by
• Integrated I- driver
part of idle • Throttle actuator
speed con‐ commanded on
troller n.a.
• Evap purge flow
< 4.0 kg/h
• Engine running
• Time after en‐
gine start > 5.0 –
25.4 s
• Clutch switch
n.a.
• Barometric
pressure > 63.0
kPa
• Catalyst heating
active
• ECT @ cylinder
block > -9° C
• And
• Set point
change < n.a.
RPM
• For time >= n.a.
s
• And
• Additional after
dynamic condi‐
tions fulfilled:
• Gear switch not
active (automat‐
ic transmission
only)
• Accelerator ped‐
al released by
driver
• Vehicle speed 0
mph
• Engine load <
100.0 % (man‐
ual transmission
only)
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P050B Ignition • Ratio be‐ • Engine idle • 0.1 s • 2 DCY – Check the
Cold Start Control tween igni‐ speed Throttle
Ignition Ignition tion angle • Once / Valve Con‐
Timing Timing efficiency • Time @ idle DCY trol Module -
Perform‐ Monitor integral and speed > 5.0 s GX3- . Refer
ance time at idle • Ignition angle to
speed > set point <= 0.77 ⇒ “3.6.45
0.20 – 0.30 [-] Throttle
[-] Valve Con‐
• Modeled pres‐ trol Module
sure quotient <= GX3 , Check‐
0.73 – 0.82 [-] ing”,
page 987 .
• Vehicle speed
=0 mph
• And
• Diff. air mass set
point vs. filtered
air mass set
point for load dy‐
namic detection
< 1,389.0 mg/
rev
• For time >= 0.4 s
• And
• Diff. engine
speed vs. fil‐
tered engine
speed for engine
speed dynamic
detection < 200
RPM
• For time >= 0.6 s
P052A Cold • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
Cold Start Start position de‐ perature 15 – (FTP75: Camshaft
"A" Cam‐ Monitor‐ viation > 130° C 45.0) s Adjustment
shaft Posi‐ ing VVT 10.0° CRK Valve 1 -
tion Timing Actuator • Engine speed • Once / N205- . Refer
Over-Ad‐ Intake 608 – 7,008 DCY to
vanced Rationali‐ RPM ⇒ “3.6.2
Bank 1 ty Check • Camshaft posi‐ Camshaft
tion not @ max. Adjustment
stop position Valve 1
N205 ,
• Camshaft posi‐ Checking”,
tion adjustment page 897 .
active
• Catalyst heating
active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 40.0°
CRK * s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P052C Cold • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
Cold Start Start position de‐ perature 15 – (FTP75: Camshaft
"A" Cam‐ Monitor‐ viation > 130° C 45.0) s Adjustment
shaft Posi‐ ing VVT 10.0° CRK Valve 2 -
tion Timing Actuator • Engine speed • Once / N208- . Refer
Over-Ad‐ Intake 608 – 7,008 DCY to
vanced Bank 2 RPM ⇒ “3.6.3
Bank 2 Rationali‐ • Camshaft posi‐ Camshaft
ty Check tion not @ max. Adjustment
stop position Valve 2
N208 ,
• Camshaft posi‐ Checking”,
tion adjustment page 899 .
active
• Catalyst heating
active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 40.0°
CRK * s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Cold • Deviation • Fuel mass set
Start between set point lower
Monitor‐ point and range >= 8.50
ing Fuel actual fuel mg/rev
System pressure > • For time >= 3.0 s
Out Of 1,500.20
Range kPa
Low
• For time >=
5.0 s
P054A Cold • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
Cold Start Start position de‐ perature 15 – (FTP75: Exhaust
"B" Cam‐ Monitor‐ viation > 130° C 45.0) s Camshaft
shaft Posi‐ ing VVT 10.0° CRK Adjustment
tion Timing Actuator • Engine speed • Once / Valve 1 -
Over-Ad‐ Outlet 608 – 7,008 DCY N318- . Refer
vanced Rationali‐ RPM to
Bank 1 ty Check • Camshaft posi‐ ⇒ “3.6.21
tion not @ max. Exhaust
stop position Camshaft
Adjustment
• Camshaft posi‐ Valve 1
tion adjustment N318 ,
active Checking”,
page 936 .
• Catalyst heating
active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 40.0°
CRK * s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P054C Cold • Camshaft • Modeled oil tem‐ • 0.0 • 2 DCY – Check the
Cold Start Start position de‐ perature 15 – (FTP75: Exhaust
"B" Cam‐ Monitor‐ viation > 130° C 45.0) s Camshaft
shaft Posi‐ ing VVT 10.0° CRK Adjustment
tion Timing Actuator • Engine speed • Once / Valve 2 -
Over-Ad‐ Outlet 608 – 7,008 DCY N319- . Refer
vanced Bank 2 RPM to
Bank 2 Rationali‐ • Camshaft posi‐ ⇒ “3.6.22
ty Check tion not @ max. Exhaust
stop position Camshaft
Adjustment
• Camshaft posi‐ Valve 2
tion adjustment N319 ,
active Checking”,
page 938 .
• Catalyst heating
active
• Camshaft posi‐
tion deviation in‐
tegrator (actual
vs. set point po‐
sition) >= 40.0°
CRK * s
– Replace the
Transmis‐
sion Control
Module -
J217- . Refer
to appropri‐
ate repair
manual.
P0603 ECM • Device 1: • 2.0 s • 2 DCY – Replace the
Internal Commu‐ faulty Engine
Control nication • SPI com‐ • Continu‐ Control Mod‐
Module Check munication ous ule . Refer to
Keep Alive with ATIC appropriate
Memory failure repair man‐
(KAM) Er‐ ual.
ror • Device 2:
– Replace the
• SPI com‐ Transmis‐
munication sion Control
with ATIC Module -
failure J217- . Refer
to appropri‐
• SPI com‐ ate repair
munication manual.
with ATIC
failure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
ECM: In‐ • Hardware • 0.2 s
jection vs. software
Valves version • Once /
Internal check dur‐ DCY
Hardware ing initiali‐
Check zation fail‐
ure
• Calibration
during initi‐
alization
failure
• Hardware
during initi‐
alization
failure
• Time refer‐
ence from
micro con‐
troller dur‐
ing initiali‐
zation fail‐
ure
• Communi‐ • 2,880.0°
cation be‐ CRK
tween micro
controller • Continu‐
and SDI- ous
Driver pow‐
er stage fail‐ • 360.0°
ure CRK
• Once /
DCY
• Communi‐ • 4,320.0°
cation be‐ CRK
tween micro
controller • Continu‐
and SDI- ous
Driver pow‐
er stage
failed
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0606 Baromet‐ • Engine_stand‐ • Engine stopped • 3.0 s • 2 DCY – Replace the
Control ric Pres‐ ing: faulty Engine
Module sure Sen‐ • Vehicle speed < • Continu‐ Control Mod‐
Processor sor Cross • Diff. pressure 1 mph ous ule . Refer to
Check downstream appropriate
throttle vs. • Engine @ driv‐
repair man‐
barometric ing cycle not
started the first ual.
pressure >=
7.5 kPa time
• Diff. baromet‐
ric pressure
vs. manifold
pressure >=
7.5 kPa
• Or
• Diff. pressure
downstream
throttle vs.
barometric
pressure >=
7.5 kPa
• Diff. baromet‐
ric pressure
vs. manifold
pressure 2 >=
7.5 kPa
• Or
• Diff. baromet‐
ric pressure
vs. manifold
pressure >=
7.5 kPa
• Diff. baromet‐
ric pressure
vs. manifold
pressure 2 >=
7.5 kPa
• Or
• Diff. pressure
downstream
throttle vs.
barometric
pressure >=
7.5 kPa
• Diff. deviation
BARO to
mean value
(MAP 2 and
MAP) vs. devi‐
ation pressure
downstream
throttle to
mean value
(MAP 2 and
MAP) > 0 kPa
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. baromet‐
ric pressure
vs. manifold
pressure >=
7.5 kPa
• Diff. deviation
BARO to
mean value
(MAP 2 and
pressure
downstream
throttle) vs.
deviation MAP
to mean value
(MAP 2 and
pressure
downstream
throttle) > 0
kPa
• Or
• Diff. baromet‐
ric pressure
vs. manifold
pressure 2 >=
7.5 kPa
• Diff. deviation
BARO to
mean value
(MAP and
pressure
downstream
throttle) vs.
deviation MAP
2 to mean val‐
ue (MAP and
pressure
downstream
throttle) > 0
kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• During • Engine stopped
ECM keep
alive-time:
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.5 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.5 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.5 kPa
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
• Or
• Diff. pres‐
sure down‐
stream
throttle vs.
barometric
pressure >=
7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐ • Vehicle speed <
tion BARO 1 mph
to mean val‐
ue (MAP 2 • ECM keep alive
and MAP) time > 10.0 s
vs. devia‐ • Time after en‐
tion pres‐ gine stop >= 4.0
sure down‐ s
stream
throttle to • Barometric
mean value pressure 55.0 –
(MAP 2 and 110.0 kPa
MAP) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure >=
7.5 kPa
• Diff. devia‐
tion BARO
to mean val‐
ue (MAP 2
and pres‐
sure down‐
stream
throttle) vs.
deviation
MAP to
mean value
(MAP 2 and
pressure
down‐
stream
throttle) > 0
kPa
• Or
• Diff. baro‐
metric pres‐
sure vs.
manifold
pressure 2
>= 7.5 kPa
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. devia‐
tion BARO
to mean val‐
ue (MAP
and pres‐
sure down‐
stream
throttle) vs.
deviation
MAP 2 to
mean value
(MAP and
pressure
down‐
stream
throttle) > 0
kPa
• Sensor cell
failure
• Finished
NVMCrypt
integrity er‐
ror
• Communi‐
cation be‐
tween sam‐
ple software
and produc‐
tion hard‐
ware error
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
ECM: • Monitoring • 0.5 s
Random module
Access check failed • Continu‐
Memory ous
(RAM)
Function‐
al Check
ECM: • SPI com‐ • Time after igni‐ • 10.0 s
Commu‐ munication tion on >= 1.0 s
nication with ATIC • Continu‐
Check failed ous
• SPI com‐
munication
with ATIC
implausible
• Monitoring • 0.01 s
of torque
difference • Continu‐
integration ous
integrated
engine tor‐
que >
655.35 Nms
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Cold • Ratio of in‐ • General condi‐ • 120.0°
Start jection fault tions: CRK
Monitor‐ counter and
ing ECM: number of • Engine running • Continu‐
Dual In‐ requested • ous
Injection on all
jection injections > cylinders active
Rationali‐ 0.13 [-] MFI and DFI ac‐
ty Check tive
• Conditions for
measurement
window:
• Catalyst heating
active
• Conditions at
fault decision:
• Catalyst heating
finished
• Requested in‐
jections > 300.0
[-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Engine • Engine
Control speed vali‐
Module dation failed
(ECM):
Electron‐
ic Throttle
Control
Module
function
monitor‐
ing: en‐
gine
speed
deviation
Engine • Validation
Control of torque
Module losses
(ECM): failed
Electron‐
ic Throttle
Control
Module
function
monitor‐
ing: tor‐
que
Engine • Validation
Control min. torque
Module @ clutch
(ECM): failed
Electron‐
ic Throttle
Control
Module
function
monitor‐
ing: tor‐
que
Engine • Validation
Control max. torque
Module @ clutch
(ECM): failed
Electron‐
ic Throttle
Control
Module
function
monitor‐
ing: tor‐
que
Engine • Validation
Control idle speed
Module engine tor‐
(ECM): que (I-Part)
Electron‐ failed
ic Throttle
Control
Module
function
monitor‐
ing: tor‐
que
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Engine • Validation
Control engine tor‐
Module que failed
(ECM):
Electron‐
ic Throttle
Control
Module
function
monitor‐
ing: tor‐
que
Engine • Validation
Control idle speed
Module engine tor‐
(ECM): que (PD-
Electron‐ Part) failed
ic Throttle
Control
Module
function
monitor‐
ing: tor‐
que
Engine • Compari‐
Control son voltage
Module sensor 1
(ECM): with sensor
Electron‐ 2 implausi‐
ic Throttle ble
Control
Module
function
monitor‐
ing: throt‐
tle posi‐
tion
P0638 Throttle • Battery volt‐ • Throttle adapta‐ • 0.01 s • 2 DCY – Check the
Throttle Actuator age <= 7.92 tion (@ initial Throttle
Actuator Basic V start or after de‐ • Once per Valve Con‐
Control Settings tection of throttle lifetime trol Module -
Range/ Adapta‐ exchange or GX3- . Refer
Perform‐ tion Val‐ checksum error) to
ance Bank ue Moni‐ active ⇒ “3.6.45
1 toring Throttle
Valve Con‐
trol Module
GX3 , Check‐
ing”,
page 987 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Accelerator
pedal value
> 99.90 %
• Or
• Engine
speed > 64
RPM
• Or
• Vehicle
speed > 2
mph
• Or
• IAT @ throt‐
tle < 6° C
• Or
• ECT @ cyl‐
inder block
< 6° C
• Or
• ECT @ cyl‐
inder block
> 105° C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Throttle po‐ • Throttle adapta‐
sition sen‐ tion demanded
sor 1 volt‐
age < 0.40 • Engine speed <
V 64 RPM
• Or • Accelerator ped‐
al value < 99.90
• Throttle po‐ %
sition sen‐
sor 2 volt‐ • Vehicle speed <
age > 4.60 2 mph
V • IAT @ throttle >
• Or 6° C
• Actual TPS
1 or 2 volt‐
age - volt‐
age ref.
point > 0.07
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0642 ECM: 5V • Analog out‐ • 0.2 s • 2 DCY – Replace the
Sensor Supply put 1 supply faulty Engine
Reference Voltage voltage < • Continu‐ Control Mod‐
Voltage Out Of 4.62 V ous ule . Refer to
"A" Circuit Range appropriate
Low Low repair man‐
ual.
P0643 ECM: 5V • Analog out‐ • 0.2 s • 2 DCY – Replace the
Sensor Supply put 1 supply faulty Engine
Reference Voltage voltage > • Continu‐ Control Mod‐
Voltage Out Of 5.43 V ous ule . Refer to
"A" Circuit Range appropriate
High High repair man‐
ual.
P064A CAN: • Fuel pump • Engine on • 1.2 s • 2 DCY – Check the
Fuel Pump Fuel signal: Fuel Delivery
Control Pump ROM / RAM • Continu‐ Unit - GX1- .
Module CAN failure feed‐ ous Refer to
Commu‐ back >= 2.0 ⇒ “3.6.23
nication [-] Fuel Delivery
With Fuel Unit GX1 ,
Pump • Fuel pump • 1.4 s Checking”,
signal: pow‐ page 940 .
er amplifier • Continu‐
failure feed‐ ous
back >= 2,0
[-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0657 Supply • Output volt‐ • Relay comman‐ • 1.5 s • 2 DCY – Check the
Actuator Voltage age lower ded off Motronic En‐
Supply Relay En‐ range >= • Continu‐ gine Control
Voltage gine 1.90 – 2.30 ous Module Pow‐
"A" Circuit/ Compo‐ V er Supply
Open nents Relay -
Open Cir‐ • Output volt‐ J271- . Refer
cuit age upper to
range ⇒ “3.6.37
(hardware Motronic En‐
values) <= gine Control
2.80 – 3.20 Module Pow‐
V er Supply
Relay J271 ,
Checking”,
page 967 .
P0658 Supply • Output volt‐ • Relay comman‐ • 1.5 s • 2 DCY – Check the
Actuator Voltage age (hard‐ ded off Motronic En‐
Supply Relay En‐ ware val‐ • Continu‐ gine Control
Voltage gine ues) < 1.90 ous Module Pow‐
"A" Circuit Compo‐ – 2.30 V er Supply
Low nents Relay -
Short To J271- . Refer
Ground to
⇒ “3.6.37
Motronic En‐
gine Control
Module Pow‐
er Supply
Relay J271 ,
Checking”,
page 967 .
P0659 Supply • Output cur‐ • Relay comman‐ • 1.5 s • 2 DCY – Check the
Actuator Voltage rent driver ded on Motronic En‐
Supply Relay En‐ stage inter‐ • Continu‐ gine Control
Voltage gine nal value ous Module Pow‐
"A" Circuit Compo‐ er Supply
High nents • Or Relay -
Short To • Actuator J271- . Refer
Battery tempera‐ to
Plus ture (hard‐ ⇒ “3.6.37
ware val‐ Motronic En‐
ues) > 175 – gine Control
195° C Module Pow‐
er Supply
Relay J271 ,
Checking”,
page 967 .
P0686 Main Re‐ • Sensed cir‐ • Main relay com‐ • 0.1 s • 2 DCY – Check the
ECM/PCM lay Ra‐ cuit voltage manded off Motronic En‐
Power Re‐ tionality > 6.0 V • Continu‐ gine Control
lay Control Check • For time >= 0.3 s ous Module Pow‐
Circuit During er Supply
Low Engine Relay -
Off J271- . Refer
to
⇒ “3.6.37
Motronic En‐
gine Control
Module Pow‐
er Supply
Relay J271 ,
Checking”,
page 967 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P0687 Main Re‐ • Sensed cir‐ • Main relay com‐ • 0.1 s • 2 DCY – Check the
ECM/PCM lay Ra‐ cuit voltage manded on Motronic En‐
Power Re‐ tionality < 5.0 V • Continu‐ gine Control
lay Control Check • for time >= 0.1 s ous Module Pow‐
Circuit During er Supply
High Engine Relay -
Running J271- . Refer
Main Re‐ • Main relay • Main relay com‐ • 0.2 s to
lay Short driver tem‐ manded on ⇒ “3.6.37
To Bat‐ perature > • Continu‐ Motronic En‐
tery Plus 175 – 195° • For time >= 0.4 s ous gine Control
C Module Pow‐
er Supply
• Or Relay J271 ,
Checking”,
• Main relay page 967 .
output cur‐
rent (hard‐
ware val‐
ues) driver
stage inter‐
nal value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Positive PWM Checking”,
signal page 920 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Super‐ • After • General condi‐ • 0.01 s
charger changed tions:
Bypass limp home • Once /
Adapta‐ position: • Vehicle speed 0 DCY
tion Val‐ mph
ue Moni‐ • Limp home
• Engine speed
toring position <
60.01° <= 64 RPM
(Top Lim‐
it / Bottom • Or • ECT @ cylinder
Limit) block 6 – 105° C
• Limp home
position > • IAT @ manifold
88.0° >= 6° C
• Time after igni‐
tion on > 2.6 s
• Depending on
stored limp
home position:
• Stored sensor
voltage @ lower
mechanical stop
< 0.35 V
• Or
• Stored sensor
voltage @ lower
mechanical stop
> 0.65 V
• Or
• Limp home posi‐
tion change de‐
tected
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. adap‐ • Recirculation
ted limp flap position
home posi‐ adaptation not
tion vs. ac‐ active
tual position
of recircula‐ • Power stage dis‐
tion flap > able
6.54° • For time >= 0.5 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P10A8 Super‐ • Sensor volt‐ • General condi‐ • 0.01 s • 2 DCY – Check the
Adaptation charger age @ low‐ tions: Control
Regulating Bypass er mechani‐ • Once / Valve Con‐
Flap For Adapta‐ cal stop < • Vehicle speed 0 DCY trol Unit -
Intake Air tion Val‐ 0.35 V mph J808- . Refer
Lower ue Moni‐ • Engine speed to
Limit Not toring • Or ⇒ “3.6.13
<= 64 RPM
Reached (Top Lim‐ • Sensor volt‐ Control
it / Bottom age @ low‐ • ECT @ cylinder Valve Con‐
Limit) er mechani‐ block 6 – 105° C trol Unit
cal stop > J808 ,
• IAT @ manifold Checking”,
0.65 V >= 6° C page 920 .
• Or • Time after igni‐
• Diff. sensor tion on > 2.6 s
voltage vs. • Depending on
sensor volt‐ stored limp
age @ low‐ home position:
er mechani‐
cal stop > • Stored sensor
0.40 V voltage @ lower
mechanical stop
• Or < 0.35 V
• Duty cycle • Or
(PWM) <=
0.0% • Stored sensor
voltage @ lower
mechanical stop
> 0.65 V
• Or
• Limp home posi‐
tion change de‐
tected
P1197 Oxygen • O2S ceram‐ • Heater com‐ • 20.0 s • 2 DCY – Check the
O2 Sensor Sensors ic tempera‐ manded on Oxygen Sen‐
Heater Cir‐ Heater ture < 680° • Continu‐ sor 2 Before
cuit Bank 2 Front 2 C • For time >= 17.0 ous Catalytic
Sensor 1 Function‐ s Converter -
al Check GX11- . Re‐
fer to
⇒ “3.6.41
Oxygen Sen‐
sor 2 Before
Catalytic
Converter
GX11 ,
Checking”,
page 978 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P12A1 Fuel Sys‐ • Phase 1 • Phase 1 DFI- • 5.0 s • 2 DCY – Check the
Fuel Rail tem Pres‐ DFI-mode mode (high pressure in
Pressure sure Sen‐ (high pres‐ pressure-part): • Continu‐ the fuel sys‐
Sensor In‐ sor, High sure-part): ous tem for out of
appropri‐ Pressure • Engine speed spec condi‐
ately Low Side Ra‐ • Deviation 576 – 3,008 tions before
tionality lambda of RPM diagnosing
Check controller the pressure
included • Mass fuel set
Low point 10.00 – sensor.
adaption <
-20.0 % 29.99 mg/rev
– Check the
• High pres‐ • Time after en‐ pressure in
sure con‐ gine start > 25.0 the fuel sys‐
troller out‐ s tem for out of
put > 30 mg • spec condi‐
Engine warm-up tions before
• And not active diagnosing
the pressure
• Phase 2 • Catalyst heating sensor. Re‐
(MPI-cross not calibrated fer to Fuel
check): • Full load not cali‐ System Me‐
brated chanical
• Lambda Testing in
controller • Lambda control ⇒ “3.1 Pre‐
included not calibrated liminary
adaption Check”,
not calibra‐ • Catalyst purge page 20 .
ted % not active
• For time not • Lambda control – Check the
calibrated not calibrated Fuel Pres‐
[s] sure Sensor -
• Evap purge G247- . Re‐
functionality di‐ fer to
agnosis not ac‐ ⇒ “3.6.27
tive Fuel Pres‐
sure Sensor
• Depending on G247 ,
low dynamic Checking”,
conditions: page 948 .
• Fuel mass set‐
point lower
range > 0.00
[mg/rev]
• For time >= 2.0
[s]
• Fuel mass set‐
point upper
range <
54.41...290.98
[mg/rev]
• Diff.fuel mass
setpoint vs. fil‐
tered fuel mass
setpoint < | 2.50
| [mg/rev]
• For time >= 3.0
[s]
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Depending on
DFI-mode (high
pressure):
• DFI high pres‐
sure part >=
0.80 [-]
• For time >= 20.0
[s]
• And
• Depending on
canister purge:
• Canister load <=
2.00 [-]
• Or
• Evap purge
valve not active
or closed
• And
• Depending on
fuel pump:
• Fuel pump at
max limit
• Or
• Fuel pump com‐
manded on
• And
• Phase2 (MFI-
cross check):
• Engine speed
not calibrated
[rpm]
• Fuel mass set‐
point (for the low
pressure part)
not calibrated
[mg/rev]
• For time not cali‐
brated [s]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P12A2 Fuel Sys‐ • Phase 1 • Phase 1 DFI- • 5.0 s • 2 DCY – Check the
Fuel Rail tem Pres‐ DFI-mode mode (high pressure in
Pressure sure Sen‐ (high pres‐ pressure-part): • Continu‐ the fuel sys‐
Sensor In‐ sor, High sure-part): ous tem for out of
appropri‐ Pressure • Engine speed spec condi‐
ately High Side Ra‐ • Deviation 576 – 3,008 tions before
tionality lambda of RPM diagnosing
Check controller the pressure
included • Mass fuel flow
High set point 34.99 – sensor.
adaption >
27.50 % 60.0 mg/rev
– Check the
• High pres‐ • Time after en‐ Fuel Pres‐
sure con‐ gine start > 25.0 sure Sensor -
troller out‐ s G247- . Re‐
put < -28 fer to
• Engine warm-up ⇒ “3.6.27
mg not active Fuel Pres‐
• And sure Sensor
• Catalyst heating G247 ,
• Phase 2 not calibrated Checking”,
(MPI-cross • Full load not cali‐ page 948 .
check): brated
• Lambda • Lambda control
controller not calibrated
included
adaption • Catalyst purge
not calibra‐ not active
ted %
• Lambda control
• For time not not calibrated
calibrated s
• Evap purge
functionality di‐
agnosis not ac‐
tive
• And
• Depending on
low dynamic
conditions:
• Fuel mass set‐
point lower
range > 0.00
[mg/rev]
• For time >= 2.0
[s]
• Fuel mass set‐
point upper
range <
54.41...290.98
[mg/rev]
• Diff.fuel mass
setpoint vs. fil‐
tered fuel mass
setpoint < | 2.50
| [mg/rev]
• For time >= 3.0
[s]
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Depending on
DFI-mode (high
pressure):
• DFI high pres‐
sure part >=
0.80 [-]
• For time >= 20.0
[s]
• And
• Depending on
canister purge:
• Canister load <=
2.00 [-]
• Or
• Evap purge
valve not active
or closed
• And
• Depending on
fuel pump:
• Fuel pump at
max limit
• Or
• Fuel pump com‐
manded on
• And
• Phase2 (MFI-
cross check):
• Engine speed
not calibrated
[rpm]
• Fuel mass set‐
point (for the low
pressure part)
not calibrated
[mg/rev]
• For time not cali‐
brated [s]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P13EA Ignition • Ratio be‐ • Engine part load • 0.1 s • 2 DCY – Check the Ig‐
Cold Start Control tween igni‐ nition Coil
Ignition Ignition tion angle • Time @ part • Once / with Power
Timing Timing efficiency load > 5.0 s DCY Output Stage
Perform‐ Monitor integral and • Ignition angle - N70- . Refer
ance Off time at part set point <= 0.77 to
Idle load > 0.20 [-] ⇒ “3.6.29 Ig‐
– 0.30 [-] nition Coils
• Vehicle speed > With Power
3 mph Output
Stage ,
• And Checking”,
page 952 .
• Diff. air mass set
point vs. filtered
air mass set
point for load dy‐
namic detection
< 1,389.0 mg/
rev
• For time >= 0.4 s
• and
• Diff. engine
speed vs. fil‐
tered engine
speed for engine
speed dynamic
detection < 200
RPM
• For time >= 0.6 s
P1545 Throttle • Control duty • Throttle position • 5.0 s • 2 DCY – Check the
Throttle Actuator cycle > 98.0 not at min. value Throttle
Actuator Out Of % • Continu‐ Valve Con‐
"A" Control Range • Throttle adapta‐ ous trol Module -
Motor Cir‐ tion not active GX3- . Refer
cuit • Throttle actuator to
Range/ commanded on ⇒ “3.6.45
Perform‐ Throttle
ance Valve Con‐
Throttle • Difference • Throttle adapta‐ • 0.5 s • 2 DCY trol Module
Actuator between tion not active GX3 , Check‐
Rationali‐ throttle po‐ • Continu‐
• Throttle actuator ous ing”,
ty Check sition set page 987 .
point and commanded on
throttle flap • Difference be‐
opening an‐ tween throttle
gle for elec‐ position set
tronic throt‐ point and throttle
tle control > flap opening an‐
2.998 – gle <= 1.999; >
24.982° -1.999° TPS
TPS
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P154A Manifold • MAP signal • 0.5 s • 2 DCY – Check the In‐
Charge air Absolute failure take Air Tem‐
pressure Pressure • Continu‐ perature
sensor (MAP) ous Sensor -
Faulty Sensor G42- / Mani‐
internal fold Absolute
hardware Pressure
check Sensor -
G71- . Refer
to
⇒ “3.6.30 In‐
take Air Tem‐
perature
Sensor G42 /
Manifold Ab‐
solute Pres‐
sure Sensor
G71 , Check‐
ing”,
page 954 .
P169A ECM: • Transport • Vehicle speed < • 0.01 s • 1 DCY • Refer to ap‐
Loading Transport mode active 3 mph propriate re‐
Mode Ac‐ Mode • Continu‐ pair manual
tive Function • Max trip mileage ous for diagnosis
Monitor‐ since initial vehi‐ and repair.
ing: Mode cle start-up <
Change 62.15 [miles
• During ECM
keep alive-time
after ignition off
• Engine speed 0
RPM
• Production
mode not active
• For hybrid:
• Drive motor off
P2004 Intake • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the In‐
Intake Manifold age > 1.76 ded off take Mani‐
Manifold Runner V • Continu‐ fold Runner
Runner Flap Ac‐ • Time after en‐ ous Control
Control tuator • For time >= gine start > 15.0 Valve -
Stuck Stuck 4.0 s s N316- . Refer
Open Open • Catalyst heating to
Bank 1 not active ⇒ “3.6.31 In‐
take Mani‐
fold Runner
Control
Valve N316 ,
Checking”,
page 956 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2005 Intake • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the In‐
Intake Manifold age > 1.76 ded off take Mani‐
Manifold Runner V • Continu‐ fold Runner
Runner Flap Ac‐ • Time after en‐ ous Control
Control tuator 2 • For time >= gine start > 15.0 Valve -
Stuck Stuck 4.0 s s N316- . Refer
Open Open • Catalyst heating to
Bank 2 not active ⇒ “3.6.31 In‐
take Mani‐
fold Runner
Control
Valve N316 ,
Checking”,
page 956 .
P2006 Intake • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the In‐
Intake Manifold age < 2.71 ded on take Mani‐
Manifold Runner V • Continu‐ fold Runner
Runner Flap Ac‐ • Time after en‐ ous Control
Control tuator • For time >= gine start > 15.0 Valve -
Stuck Stuck 4.0 s s N316- . Refer
Closed Close • Catalyst heating to
Bank 1 not active ⇒ “3.6.31 In‐
take Mani‐
fold Runner
Control
Valve N316 ,
Checking”,
page 956 .
P2007 Intake • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the In‐
Intake Manifold age < 2.71 ded on take Mani‐
Manifold Runner V • Continu‐ fold Runner
Runner Flap Ac‐ • Time after en‐ ous Control
Control tuator 2 • For time >= gine start > 15.0 Valve -
Stuck Stuck 4.0 s s N316- . Refer
Closed Close • Catalyst heating to
Bank 2 not active ⇒ “3.6.31 In‐
take Mani‐
fold Runner
Control
Valve N316 ,
Checking”,
page 956 .
P2008 Intake • Output volt‐ • Engine running • 2.0 s • 2 DCY – Check the In‐
Intake Manifold age, lower take Mani‐
Manifold Runner range >= • Actuator com‐ • Continu‐ fold Runner
Runner Flap Ac‐ 1.92 – 2.21 manded off ous Control
Control tuator V Valve -
Circuit/ Open Cir‐ N316- . Refer
Open cuit • Output volt‐ to
Bank 1 age, upper ⇒ “3.6.31 In‐
range take Mani‐
(hardware fold Runner
values) <= Control
2.85 – 3.25 Valve N316 ,
V Checking”,
page 956 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2009 Intake • Output volt‐ • Engine running • 2.0 s • 2 DCY – Check the In‐
Intake Manifold age (hard‐ take Mani‐
Manifold Runner ware val‐ • Actuator com‐ • Continu‐ fold Runner
Runner Flap Ac‐ ues) < 1.92 manded off ous Control
Control tuator – 2.21 V Valve -
Circuit Short To N316- . Refer
Low Bank Ground • Output volt‐ to
1 age, upper ⇒ “3.6.31 In‐
range <= take Mani‐
2.85 – 3.25 fold Runner
V Control
Valve N316 ,
Checking”,
page 956 .
P2010 Intake • Power • Engine running • 2.0 s • 2 DCY – Check the In‐
Intake Manifold stage tem‐ take Mani‐
Manifold Runner perature > • Actuator com‐ • Continu‐ fold Runner
Runner Flap Ac‐ 160 – 200° manded on ous Control
Control tuator C Valve -
Circuit Short To N316- . Refer
High Bank Battery • Or to
1 Plus • Output cur‐ ⇒ “3.6.31 In‐
rent (hard‐ take Mani‐
ware val‐ fold Runner
ues) driver Control
stage inter‐ Valve N316 ,
nal value Checking”,
page 956 .
P2014 Intake • Intake • Engine start not • 0.2 s • 2 DCY – Check the In‐
Intake Manifold manifold active take Mani‐
Manifold Runner runner flap • Continu‐ fold Runner
Runner Flap Po‐ position ous Position
Position sition sensor volt‐ Sensor -
Sensor/ Sensor age < 0.20 G336- . Re‐
Switch Cir‐ Short To V fer to
cuit Bank 1 Ground / ⇒ “3.6.32 In‐
Open Cir‐ take Mani‐
cuit fold Runner
Position
Sensor
G336 ,
Checking”,
page 958 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2015 Intake • Diff. actual • Modeled pres‐ • 0.04 s • 2 DCY – Check the In‐
Intake Manifold value vs. sure quotient < take Mani‐
Manifold Runner substitution 0.55 [-] • Once per fold Runner
Runner Flap Ac‐ value @ lifetime Position
Position tuator lower me‐ • Engine running Sensor -
Sensor/ Adapta‐ chanical • Engine speed > G336- . Re‐
Switch Cir‐ tion Val‐ thresh hold 512; < 992 rpm fer to
cuit ue Moni‐ > 0.86 V ⇒ “3.6.32 In‐
Range/ toring • Ect @ cylinder take Mani‐
Perform‐ • Or block > 6° c fold Runner
ance Bank • Diff. actual • Position
1 Intake manifold Sensor
value vs. runner flap
substitution G336 ,
adaptation not Checking”,
value @ up‐ finished
per me‐ page 958 .
chanical
thresh hold
> 0.86 V
• Failed
adaptations
>= 1.00 [-]
P2017 Intake • Intake • Engine start not • 0.2 s • 2 DCY – Check the In‐
Intake Manifold manifold active take Mani‐
Manifold Runner runner flap • Continu‐ fold Runner
Runner Flap Po‐ position ous Position
Position sition sensor volt‐ Sensor -
Sensor/ Sensor age > 4.80 G336- . Re‐
Switch Cir‐ Short To V fer to
cuit High Battery ⇒ “3.6.32 In‐
Bank 1 Plus take Mani‐
fold Runner
Position
Sensor
G336 ,
Checking”,
page 958 .
P2019 Intake • Intake • Engine start not • 0.2 s • 2 DCY – Check the In‐
Intake Manifold manifold active take Mani‐
Manifold Runner runner flap • Continu‐ fold Runner
Runner Flap Po‐ position ous Position
Position sition sensor volt‐ Sensor 2 -
Sensor/ Sensor age < 0.20 G512- . Re‐
Switch Cir‐ Bank 2 V fer to
cuit Bank 2 Short To ⇒ “3.6.33 In‐
Ground / take Mani‐
Open Cir‐ fold Runner
cuit Position
Sensor 2
G512 ,
Checking”,
page 960 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2020 Intake • Diff. actual • Modeled pres‐ • 0.04 s • 2 DCY – Check the In‐
Intake Manifold value vs. sure quotient < take Mani‐
Manifold Runner substitution 0.55 [-] • Once per fold Runner
Runner Flap Ac‐ value @ lifetime Position
Position tuator 2 lower me‐ • Engine running Sensor 2 -
Sensor/ Adapta‐ chanical • Engine speed > G512- . Re‐
Switch Cir‐ tion Val‐ thresh hold 512; < 992 rpm fer to
cuit ue Moni‐ > 0.86 V ⇒ “3.6.33 In‐
Range/ toring • Ect @ cylinder take Mani‐
Perform‐ • Or block > 6° c fold Runner
ance Bank • Diff. actual • Position
2 Intake manifold Sensor 2
value vs. runner flap
substitution G512 ,
adaptation not Checking”,
value @ up‐ finished
per me‐ page 960 .
chanical
thresh hold
> 0.86 V
• Failed
adaptations
>= 1.00 [-]
P2022 Intake • Intake • Engine start not • 0.2 s • 2 DCY – Check the In‐
Intake Manifold manifold active take Mani‐
Manifold Runner runner flap • Continu‐ fold Runner
Runner Flap Po‐ position ous Position
Position sition sensor volt‐ Sensor 2 -
Sensor/ Sensor age > 4.80 G512- . Re‐
Switch Cir‐ Bank 2 V fer to
cuit High Short To ⇒ “3.6.33 In‐
Bank 2 Battery take Mani‐
Plus fold Runner
Position
Sensor 2
G512 ,
Checking”,
page 960 .
P2024 Smart • NVLD out‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Fuel Tempera‐ put voltage Fuel Tank
Vapor ture Sen‐ lower range • Ignition on • Continu‐ Leak Detec‐
Tempera‐ sor Open >= 1.92 – ous tion Control
• Case 2:
ture Sen‐ Circuit 2.21 V Module -
sor Circuit • Ignition off (dur‐ J909- . Refer
• NVLD out‐ ing ECM keep to
put voltage alive-time) ⇒ “3.6.28
upper range Fuel Tank
<= 2.85 – Leak Detec‐
3.25 V tion Control
Module
J909 ,
Checking”,
page 950 .
P2025 Smart • Diff. time • Ignition off • 3.0 s • 2 DCY – Check the
EVAP Fuel Tempera‐ between Fuel Tank
Vapor ture Sen‐ ECU and • ECM keep alive • Once / Leak Detec‐
Tempera‐ sor Func‐ smart mod‐ time active DCY tion Control
ture Sen‐ tional ule > 3.0 s Module -
sor Per‐ Check J909- . Refer
formance to
⇒ “3.6.28
Fuel Tank
Leak Detec‐
tion Control
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Reset coun‐ • Engine running • 0.1 s Module
ter > 3.00 [-] J909 ,
• Last ECM keep • Once / Checking”,
alive mode fin‐ DCY page 950 .
ished
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Smart • Diff. be‐ • Engine off time
Tempera‐ tween >= 480.0 min
ture Sen‐ smart tem‐
sor Sig‐ perature @ • IAT cross check
nal Cross engine start finished
Check and ECT @ • ECT cross
cylinder check finished
block @ en‐
gine start • Fuel level <
>= 24.8 K 85.10 %
• And
• Diff. be‐
tween
smart tem‐
perature @
engine start
and IAT @
manifold @
engine start
>= 24.8 K
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2027 Smart • NVLD out‐ • Case 1: • 0.5 s • 2 DCY – Check the
EVAP Fuel Tempera‐ put temper‐ Fuel Tank
Vapor ture Sen‐ ature > • Ignition on • Continu‐ Leak Detec‐
Tempera‐ sor Short 160.0 – ous tion Control
• Case 2:
ture Sen‐ To Bat‐ 200.0° C Module -
sor Circuit tery Plus • Ignition off (dur‐ J909- . Refer
High Volt‐ • Or ing ECM keep to
age • NVLD out‐ alive-time) ⇒ “3.6.28
put current Fuel Tank
driver stage Leak Detec‐
internal val‐ tion Control
ue Module
J909 ,
Checking”,
page 950 .
P2067 CAN: • Instrument • 0.5 s • 2 DCY – Refer to ap‐
Fuel Level Fuel Lev‐ cluster propriate wir‐
Sensor "B" el Sensor module sig‐ • Continu‐ ing diagram.
Circuit 2 CAN nal: short to ous If fuel level
Low Commu‐ ground fail‐ sensor and
nication ure circuitry are
With In‐ ok, then re‐
strument • Instrument place the in‐
Cluster cluster strument
Module module sig‐ cluster. Re‐
nal: signal fer to appro‐
range priate repair
check fail‐ manual.
ure
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2089 VVT Ac‐ • Power • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"A" Cam‐ tuator In‐ stage tem‐ tor solenoid Camshaft
shaft Posi‐ take perature > valve comman‐ • Continu‐ Adjustment
tion Actua‐ Short To 160 – 200° ded on ous Valve 1 -
tor Control Battery C N205- . Refer
Circuit Plus to
High Bank • Or ⇒ “3.6.2
1 • Output cur‐ Camshaft
rent (hard‐ Adjustment
ware val‐ Valve 1
ues) driver N205 ,
stage inter‐ Checking”,
nal value page 897 .
P2090 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator age (hard‐ tor solenoid Exhaust
shaft Posi‐ Outlet ware val‐ valve comman‐ • Continu‐ Camshaft
tion Actua‐ Short To ues) < 1.92 ded off ous Adjustment
tor Control Ground – 2.21 V Valve 1 -
Circuit N318- . Refer
Low Bank to
1 ⇒ “3.6.21
Exhaust
Camshaft
Adjustment
Valve 1
N318 ,
Checking”,
page 936 .
P2091 VVT Ac‐ • Power • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator stage tem‐ tor solenoid Exhaust
shaft Posi‐ Outlet perature > valve comman‐ • Continu‐ Camshaft
tion Actua‐ Short To 160 – 200° ded on ous Adjustment
tor Control Battery C Valve 1 -
Circuit Plus N318- . Refer
High Bank • Or to
1 • Output cur‐ ⇒ “3.6.21
rent (hard‐ Exhaust
ware val‐ Camshaft
ues) driver Adjustment
stage inter‐ Valve 1
nal value N318 ,
Checking”,
page 936 .
P2092 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"A" Cam‐ tuator In‐ age (hard‐ tor solenoid Camshaft
shaft Posi‐ take ware val‐ valve comman‐ • Continu‐ Adjustment
tion Actua‐ Bank 2 ues) < 1.92 ded off ous Valve 2 -
tor Control Short To – 2.21 V N208- . Refer
Circuit Ground to
Low Bank ⇒ “3.6.3
2 Camshaft
Adjustment
Valve 2
N208 ,
Checking”,
page 899 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2093 VVT Ac‐ • Power • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"A" Cam‐ tuator In‐ stage tem‐ tor solenoid Camshaft
shaft Posi‐ take perature > valve comman‐ • Continu‐ Adjustment
tion Actua‐ Bank 2 160 – 200° ded on ous Valve 2 -
tor Control Short To C N208- . Refer
Circuit Battery to
High Bank Plus • Or ⇒ “3.6.3
2 • Output cur‐ Camshaft
rent (hard‐ Adjustment
ware val‐ Valve 2
ues) driver N208 ,
stage inter‐ Checking”,
nal value page 899 .
P2094 VVT Ac‐ • Output volt‐ • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator age (hard‐ tor solenoid Exhaust
shaft Posi‐ Outlet ware val‐ valve comman‐ • Continu‐ Camshaft
tion Actua‐ Bank 2 ues) < 1.92 ded off ous Adjustment
tor Control Short To – 2.21 V Valve 2 -
Circuit Ground N319- . Refer
Low Bank to
2 ⇒ “3.6.22
Exhaust
Camshaft
Adjustment
Valve 2
N319 ,
Checking”,
page 938 .
P2095 VVT Ac‐ • Power • Camshaft actua‐ • 2.0 s • 2 DCY – Check the
"B" Cam‐ tuator stage tem‐ tor solenoid Exhaust
shaft Posi‐ Outlet perature > valve comman‐ • Continu‐ Camshaft
tion Actua‐ Bank 2 160 – 200° ded on ous Adjustment
tor Control Short To C Valve 2 -
Circuit Battery N319- . Refer
High Bank Plus • Or to
2 • Output cur‐ ⇒ “3.6.22
rent (hard‐ Exhaust
ware val‐ Camshaft
ues) driver Adjustment
stage inter‐ Valve 2
nal value N319 ,
Checking”,
page 938 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2096 Fuel Sys‐ • Adaption • 2nd lambda con‐ • 45.0 s • 2 DCY – Check the
Post Cata‐ tem Out value < trol n.a. Oxygen Sen‐
lyst Fuel Of Range -0.10 [-] • Continu‐ sor 1 Before
Trim Sys‐ Low • Catalyst purge ous Catalytic
tem Too not active Converter -
Lean Bank • Injection mode GX10- . Re‐
1 change (DFI/ fer to
MFI) not active ⇒ “3.6.39
Oxygen Sen‐
• Engine speed sor 1 Before
>= 608 RPM Catalytic
Converter
• Counter of inte‐ GX10 ,
grated mass for Checking”,
fuel in oil < 255.0 page 972 .
[-]
– Check the
• Choice of: Oxygen Sen‐
• O2S rear (bina‐ sor 1 After
ry) check not ac‐ Catalytic
tive Converter -
GX7- . Refer
• Or to
⇒ “3.6.38
• O2S rear (bina‐ Oxygen Sen‐
ry) check finish‐ sor 1 After
ed Catalytic
Converter
GX7 , Check‐
ing”,
page 970 .
– Check the
Three Way
Catalytic
Converter
(TWC). Re‐
fer to
⇒ “3.6.44
Three Way
Catalytic
Converter
(TWC),
Checking”,
page 986 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2097 Fuel Sys‐ • Adaption • 2nd lambda con‐ • 45.0 s • 2 DCY – Check the
Post Cata‐ tem Out value > 0.10 trol n.a. Oxygen Sen‐
lyst Fuel Of Range [-] • Continu‐ sor 1 Before
Trim Sys‐ High • Catalyst purge ous Catalytic
tem Too not active Converter -
Rich Bank • Injection mode GX10- . Re‐
1 change (DFI/ fer to
MFI) not active ⇒ “3.6.39
Oxygen Sen‐
• Engine speed sor 1 Before
>= 608 RPM Catalytic
Converter
• Counter of inte‐ GX10 ,
grated mass for Checking”,
fuel in oil < 255.0 page 972 .
[-]
– Check the
• Choice of: Oxygen Sen‐
• O2S rear (bina‐ sor 1 After
ry) check not ac‐ Catalytic
tive Converter -
GX7- . Refer
• Or to
⇒ “3.6.38
• O2S rear (bina‐ Oxygen Sen‐
ry) check finish‐ sor 1 After
ed Catalytic
Converter
GX7 , Check‐
ing”,
page 970 .
– Check the
Three Way
Catalytic
Converter
(TWC). Re‐
fer to
⇒ “3.6.44
Three Way
Catalytic
Converter
(TWC),
Checking”,
page 986 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2098 Fuel Sys‐ • Adaption • 2nd lambda con‐ • 45.0 s • 2 DCY – Check the
Post Cata‐ tem Out value < trol n.a. Oxygen Sen‐
lyst Fuel Of Range -0.10 [-] • Continu‐ sor 2 Before
Trim Sys‐ Low • Catalyst purge ous Catalytic
tem Too not active Converter -
Lean Bank • Injection mode GX11- . Re‐
2 change (DFI/ fer to
MFI) not active ⇒ “3.6.41
Oxygen Sen‐
• Engine speed sor 2 Before
>= 608 RPM Catalytic
Converter
• Counter of inte‐ GX11 ,
grated mass for Checking”,
fuel in oil < 255.0 page 978 .
[-]
– Check the
• Choice of: Oxygen Sen‐
• O2S rear (bina‐ sor 2 After
ry) check not ac‐ Catalytic
tive Converter -
GX8- . Refer
• Or to
⇒ “3.6.40
• O2S rear (bina‐ Oxygen Sen‐
ry) check finish‐ sor 2 After
ed Catalytic
Converter
GX8 , Check‐
ing”,
page 976 .
– Check the
Three Way
Catalytic
Converter
(TWC). Re‐
fer to
⇒ “3.6.44
Three Way
Catalytic
Converter
(TWC),
Checking”,
page 986 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2099 Fuel Sys‐ • Adaption • 2nd lambda con‐ • 45.0 s • 2 DCY – Check the
Post Cata‐ tem Out value > 0.10 trol n.a. Oxygen Sen‐
lyst Fuel Of Range [-] • Continu‐ sor 2 Before
Trim Sys‐ High • Catalyst purge ous Catalytic
tem Too not active Converter -
Rich Bank • Injection mode GX11- . Re‐
2 change (DFI/ fer to
MFI) not active ⇒ “3.6.41
Oxygen Sen‐
• Engine speed sor 2 Before
>= 608 RPM Catalytic
Converter
• Counter of inte‐ GX11 ,
grated mass for Checking”,
fuel in oil < 255.0 page 978 .
[-]
– Check the
• Choice of: Oxygen Sen‐
• O2S rear (bina‐ sor 2 After
ry) check not ac‐ Catalytic
tive Converter -
GX8- . Refer
• Or to
⇒ “3.6.40
• O2S rear (bina‐ Oxygen Sen‐
ry) check finish‐ sor 2 After
ed Catalytic
Converter
GX8 , Check‐
ing”,
page 976 .
– Check the
Three Way
Catalytic
Converter
(TWC). Re‐
fer to
⇒ “3.6.44
Three Way
Catalytic
Converter
(TWC),
Checking”,
page 986 .
P2100 Throttle • Electronic • Difference be‐ • 0.1 s • 2 DCY – Check the
Throttle Actuator throttle tween meas‐ Throttle
Actuator Open Cir‐ valve driver ured and filtered • Continu‐ Valve Con‐
"A" Control cuit load resist‐ throttle position ous trol Module -
Motor Cir‐ ance > <= 0.073° TPS GX3- . Refer
cuit/Open 200.0 to
kOhm • Actuator com‐ ⇒ “3.6.45
manded off Throttle
Valve Con‐
trol Module
GX3 , Check‐
ing”,
page 987 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2101 Throttle • Electronic • Actuator com‐ • 0.1 s • 2 DCY – Check the
Throttle Actuator throttle manded on Throttle
Actuator Over valve driver • Continu‐ Valve Con‐
"A" Control Tempera‐ tempera‐ ous trol Module -
Motor Cir‐ ture ture (hard‐ GX3- . Refer
cuit ware val‐ to
Range/ ues) > ⇒ “3.6.45
Perform‐ 170.0 – Throttle
ance 190.0° C Valve Con‐
trol Module
GX3 , Check‐
ing”,
page 987 .
P2103 Throttle • Electronic • Actuator com‐ • 0.1 s • 2 DCY – Check the
Throttle Actuator throttle manded on Throttle
Actuator Short Cir‐ valve driver • Continu‐ Valve Con‐
"A" Control cuit current ous trol Module -
Motor Cir‐ (hardware GX3- . Refer
cuit High values) to
driver stage ⇒ “3.6.45
internal val‐ Throttle
ue Valve Con‐
trol Module
GX3 , Check‐
ing”,
page 987 .
P2121 Accelera‐ • APP 1 sig‐ • 0.1 s • 2 DCY – Check the
Throttle/ tor Pedal nal failure Accelerator
Pedal Po‐ Position • Continu‐ Pedal Mod‐
sition Sen‐ (APP) ous ule - GX2- .
sor/Switch Sensor 1 Refer to
"D" Circuit internal ⇒ “3.6.1 Ac‐
Range/ hardware celerator
Perform‐ check Pedal Mod‐
ance ule GX2 ,
Checking”,
page 895 .
P2122 Accelera‐ • Signal volt‐ • 0.3 s • 2 DCY – Check the
Throttle/ tor Pedal age sensor Accelerator
Pedal Po‐ Position 1 < 0.40 V • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 1 ous ule - GX2- .
sor/Switch Out Of Refer to
"D" Circuit Range ⇒ “3.6.1 Ac‐
Low Low celerator
Pedal Mod‐
ule GX2 ,
Checking”,
page 895 .
P2123 Accelera‐ • Signal volt‐ • 0.3 s • 2 DCY – Check the
Throttle/ tor Pedal age sensor Accelerator
Pedal Po‐ Position 1 > 4.85 V • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 1 ous ule - GX2- .
sor/Switch Out Of Refer to
"D" Circuit Range ⇒ “3.6.1 Ac‐
High High celerator
Pedal Mod‐
ule GX2 ,
Checking”,
page 895 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2126 Accelera‐ • APP 2 sig‐ • 0.1 s • 2 DCY – Check the
Throttle/ tor Pedal nal failure Accelerator
Pedal Po‐ Position • Continu‐ Pedal Mod‐
sition Sen‐ (APP) ous ule - GX2- .
sor/Switch Sensor 2 Refer to
"E" Circuit internal ⇒ “3.6.1 Ac‐
Range/ hardware celerator
Perform‐ check Pedal Mod‐
ance ule GX2 ,
Checking”,
page 895 .
P2127 Accelera‐ • Signal volt‐ • 0.3 s • 2 DCY – Check the
Throttle/ tor Pedal age sensor Accelerator
Pedal Po‐ Position 2 < 0.20 V • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 2 ous ule - GX2- .
sor/Switch Out Of Refer to
"E" Circuit Range ⇒ “3.6.1 Ac‐
Low Low celerator
Pedal Mod‐
ule GX2 ,
Checking”,
page 895 .
P2128 Accelera‐ • Signal volt‐ • 0.3 s • 2 DCY – Check the
Throttle/ tor Pedal age sensor Accelerator
Pedal Po‐ Position 2 > 2.80 V • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 2 ous ule - GX2- .
sor/Switch Out Of Refer to
"E" Circuit Range ⇒ “3.6.1 Ac‐
High High celerator
Pedal Mod‐
ule GX2 ,
Checking”,
page 895 .
P2138 Accelera‐ • Difference • 0.4 s • 2 DCY – Check the
Throttle/ tor Pedal between Accelerator
Pedal Po‐ Position signal volt‐ • Continu‐ Pedal Mod‐
sition Sen‐ Sensor 1 age sensor ous ule - GX2- .
sor/Switch and 2 Ra‐ 1 and sen‐ Refer to
"D"/"E" tionality sor 2 > 0.10 ⇒ “3.6.1 Ac‐
Voltage Check – 0.12 V celerator
Correla‐ Pedal Mod‐
tion ule GX2 ,
Checking”,
page 895 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2177 Fuel Sys‐ • Adaptive • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
System tem Too value >= 25 mg/rev Oxygen Sen‐
Too Lean Lean @ % • Continu‐ sor 1 Before
Off Idle Part Load • ECT @ cylinder ous Catalytic
Bank 1 block > 70° C Converter -
• IAT @ manifold GX10- . Re‐
> -11° C fer to
⇒ “3.6.39
• AAT > -48° C Oxygen Sen‐
sor 1 Before
• Lambda set Catalytic
point 0.92 – 1.05 Converter
[-] GX10 ,
Checking”,
• Lambda control page 972 .
closed loop
• Integrated air – Check the
mass >= 30.0 g Oxygen Sen‐
sor 1 After
• Mass fuel flow Catalytic
13.01 – 36.01 Converter -
mg/rev GX7- . Refer
to
• Engine speed ⇒ “3.6.38
704 – 4,960 Oxygen Sen‐
RPM sor 1 After
• Ethanol value Catalytic
n.a. Converter
GX7 , Check‐
• Low dynamic ing”,
conditions: page 970 .
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge flow
at max. value
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2178 Fuel Sys‐ • Adaptive • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
System tem Too value <= mg/rev Oxygen Sen‐
Too Rich Rich @ -25 % • Continu‐ sor 1 Before
Off Idle Part Load • ECT @ cylinder ous Catalytic
Bank 1 block > 70° C Converter -
• IAT @ manifold GX10- . Re‐
> -11° C fer to
⇒ “3.6.39
• AAT > -48° C Oxygen Sen‐
sor 1 Before
• Lambda set Catalytic
point 0.92 – 1.05 Converter
[-] GX10 ,
Checking”,
• Lambda control page 972 .
closed loop
• Integrated air – Check the
mass >= 30.0 g Oxygen Sen‐
sor 1 After
• Mass fuel flow Catalytic
13.01 – 36.01 Converter -
mg/rev GX7- . Refer
to
• Engine speed ⇒ “3.6.38
704 – 4,960 Oxygen Sen‐
RPM sor 1 After
• Ethanol value Catalytic
n.a. Converter
GX7 , Check‐
• Low dynamic ing”,
conditions: page 970 .
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge flow
at max. value
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2179 Fuel Sys‐ • Adaptive • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
System tem Too value >= 25 mg/rev Oxygen Sen‐
Too Lean Lean @ % • Continu‐ sor 2 Before
Off Idle Part Load • ECT @ cylinder ous Catalytic
Bank 2 block > 70° C Converter -
• IAT @ manifold GX11- . Re‐
> -11° C fer to
⇒ “3.6.41
• AAT > -48° C Oxygen Sen‐
sor 2 Before
• Lambda set Catalytic
point 0.92 – 1.05 Converter
[-] GX11 ,
Checking”,
• Lambda control page 978 .
closed loop
• Integrated air – Check the
mass >= 30.0 g Oxygen Sen‐
sor 2 After
• Mass fuel flow Catalytic
13.01 – 36.01 Converter -
mg/rev GX8- . Refer
to
• Engine speed ⇒ “3.6.40
704 – 4,960 Oxygen Sen‐
RPM sor 2 After
• Ethanol value Catalytic
n.a. Converter
GX8 , Check‐
• Low dynamic ing”,
conditions: page 976 .
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge flow
at max. value
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2180 Fuel Sys‐ • Adaptive • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
System tem Too value <= mg/rev Oxygen Sen‐
Too Rich Rich @ -25 % • Continu‐ sor 2 Before
Off Idle Part Load • ECT @ cylinder ous Catalytic
Bank 2 block > 70° C Converter -
• IAT @ manifold GX11- . Re‐
> -11° C fer to
⇒ “3.6.41
• AAT > -48° C Oxygen Sen‐
sor 2 Before
• Lambda set Catalytic
point 0.92 – 1.05 Converter
[-] GX11 ,
Checking”,
• Lambda control page 978 .
closed loop
• Integrated air – Check the
mass >= 30.0 g Oxygen Sen‐
sor 2 After
• Mass fuel flow Catalytic
13.01 – 36.01 Converter -
mg/rev GX8- . Refer
to
• Engine speed ⇒ “3.6.40
704 – 4,960 Oxygen Sen‐
RPM sor 2 After
• Ethanol value Catalytic
n.a. Converter
GX8 , Check‐
• Low dynamic ing”,
conditions: page 976 .
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge flow
at max. value
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2181 Engine • Modeled • ECT @ cylinder • 1.0 s • 2 DCY – Check the
Cooling Cooling ECT @ cyl‐ block @ first Engine Cool‐
System System inder block start >= -8° C • Once / ant Temper‐
Perform‐ Rationali‐ > 87° C DCY ature Sensor
ance ty Check • ECT @ cylinder - G62- . Refer
• Choice of: block @ first to
start <= -48 – ⇒ “3.6.17
• ECT @ cyl‐ 57° C
inder block Engine Cool‐
< -48 – 76° • AAT > -8° C ant Temper‐
C ature Sensor
• Ratio accumula‐ G62 , Check‐
• Or ted time fuel cut ing”,
off vs. time since page 928 .
• ECT @ cyl‐ engine start <=
inder head 14.06 % – Check the
< n.a.° C Cylinder
• Ratio accumula‐ Head Cool‐
ted time engine ant Valve -
load condition N489- . Refer
vs. time since to
engine start <= ⇒ “3.6.15
42.19 % Cylinder
Head Cool‐
• Determination ant Valve
engine load con‐ N489 ,
dition: Checking”,
• Engine load page 924 .
(lower thresh‐
old) <= 2.50 % – Check the
Engine Tem‐
• Engine load (up‐ perature
per threshold) Control Sen‐
>= 2.50 % sor - G694- .
Refer to
• Ratio accumula‐ ⇒ “3.6.19
ted time high Engine Tem‐
speed condition perature
<= 40.23 % Control Sen‐
• Determination sor G694 ,
high speed con‐ Checking”,
dition: page 932 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• For time >= 40.0
s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2187 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
System tem Too mg/rev Oxygen Sen‐
Too Lean Lean @ • Adaptive • Continu‐ sor 1 Before
at Idle Idle value >= • ECT @ cylinder ous Catalytic
Bank 1 n.a. mg/rev block > 70° C Converter -
• Case 2: • IAT @ manifold GX10- . Re‐
> -11° C fer to
• Adaptive ⇒ “3.6.39
value >= • AAT > -48° C Oxygen Sen‐
0.33 kg/h sor 1 Before
• Lambda set Catalytic
point 0.92 – 1.05 Converter
[-] GX10 ,
Checking”,
• Lambda control page 972 .
closed loop
• Integrated air
mass >= 30.0 g
• Vehicle speed <
31 mph
• Ethanol value
n.a.
• Low dynamic
conditions:
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Mass fuel flow
upper range <
0.0 – 15.01 mg/
rev
• Mass fuel flow
lower range >
5.0 – 9.01 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Engine speed
704 – 1,504
RPM
• Or
• Engine n.a.
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
• Evap purge flow
at max. value
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2188 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
System tem Too mg/rev Oxygen Sen‐
Too Rich Rich @ • Adaptive • Continu‐ sor 1 Before
at Idle Idle value <= • ECT @ cylinder ous Catalytic
Bank 1 n.a. mg/rev block > 70° C Converter -
• Case 2: • IAT @ manifold GX10- . Re‐
> -11° C fer to
• Adaptive ⇒ “3.6.39
value <= • AAT > -48° C Oxygen Sen‐
-0.33 kg/h sor 1 Before
• Lambda set Catalytic
point 0.92 – 1.05 Converter
[-] GX10 ,
Checking”,
• Lambda control page 972 .
closed loop
• Oil dilution not
detected
• Integrated air
mass >= 30.0 g
• Vehicle speed <
31 mph
• Ethanol value
n.a.
• Low dynamic
conditions:
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Mass fuel flow
lower range >
5.0 – 9.01 mg/
rev
• Mass fuel flow
upper range <
0.0 – 15.01 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Engine speed
704 – 1,504
RPM
• Or
• Engine n.a.
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
• Evap purge flow
at max. value
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2189 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
System tem Too mg/rev Oxygen Sen‐
Too Lean Lean @ • Adaptive • Continu‐ sor 2 Before
at Idle Idle value >= • ECT @ cylinder ous Catalytic
Bank 2 n.a. mg/rev block > 70° C Converter -
• Case 2: • IAT @ manifold GX11- . Re‐
> -11° C fer to
• Adaptive ⇒ “3.6.41
value >= • AAT > -48° C Oxygen Sen‐
0.33 kg/h sor 2 Before
• Lambda set Catalytic
point 0.92 – 1.05 Converter
[-] GX11 ,
Checking”,
• Lambda control page 978 .
closed loop
• Integrated air
mass >= 30.0 g
• Vehicle speed <
31 mph
• Ethanol value
n.a.
• Low dynamic
conditions:
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Mass fuel flow
upper range <
0.0 – 15.01 mg/
rev
• Mass fuel flow
lower range >
5.0 – 9.01 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Engine speed
704 – 1,504
RPM
• Or
• Engine n.a.
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
• Evap purge flow
at max. value
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2190 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
System tem Too mg/rev Oxygen Sen‐
Too Rich Rich @ • Adaptive • Continu‐ sor 2 Before
at Idle Idle value <= • ECT @ cylinder ous Catalytic
Bank 2 n.a. mg/rev block > 70° C Converter -
• Case 2: • IAT @ manifold GX11- . Re‐
> -11° C fer to
• Adaptive ⇒ “3.6.41
value <= • AAT > -48° C Oxygen Sen‐
-0.33 kg/h sor 2 Before
• Lambda set Catalytic
point 0.92 – 1.05 Converter
[-] GX11 ,
Checking”,
• Lambda control page 978 .
closed loop
• Oil dilution not
detected
• Integrated air
mass >= 30.0 g
• Vehicle speed <
31 mph
• Ethanol value
n.a.
• Low dynamic
conditions:
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 150
RPM
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 130.01
mg/rev
• Diff. between
reference and
actual fuel pres‐
sure, high side
<= 34,777.60
kPa
• Integrated air
mass > 15.0 –
70.0 g
• And
• Mass fuel flow
lower range >
5.0 – 9.01 mg/
rev
• Mass fuel flow
upper range <
0.0 – 15.01 mg/
rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Engine speed
704 – 1,504
RPM
• Or
• Engine n.a.
• And
• Evap purge
valve closed
• Or
• Canister load <=
2.0 [-]
• Evap purge flow
at max. value
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2195 Oxygen • Plausibility • O2S front ready • 270.0 s • 2 DCY – Check the
O2 Sensor Sensors check up‐ Oxygen Sen‐
Signal Front Ra‐ stream and • O2S rear ready • Continu‐ sor 1 Before
Biased/ tionality down‐ ous Catalytic
• ECT @ cylinder
Stuck Check stream oxy‐ block >= 60° C Converter -
Lean Bank gen sensor GX10- . Re‐
1 Sensor 1 signal: • MAF > 30.00; < fer to
300.0 kg/h ⇒ “3.6.39
• Lambda Oxygen Sen‐
value > 1.24 • Catalyst purge sor 1 Before
[-] not active Catalytic
• And Converter
• Integrated air GX10 ,
mass after end
• O2S signal Checking”,
of catalyst purge
rear >= 0.82 page 972 .
>= 0.0 g
V
• Engine speed >
992 RPM
• EGT @ O2S
front > 300; <
841° C
• Injection mode
change (DFI/
MFI) not active
• Integrated air
mass > 40.0 g
• Dynamic lamb‐
da controller
output < 3.0 %
• Dynamic MAF <
0.10 g/rev
• Dynamic engine
speed < 300
RPM
• And
• Second control
loop active:
• Air mass 0.07 –
0.85 g/rev
• Engine speed
608 – 4,512
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2196 Oxygen • Plausibility • O2S front ready • 270.0 s • 2 DCY – Check the
O2 Sensor Sensors check up‐ Oxygen Sen‐
Signal Front Ra‐ stream and • O2S rear ready • Continu‐ sor 1 Before
Biased/ tionality down‐ ous Catalytic
• ECT @ cylinder
Stuck Rich Check stream oxy‐ block >= 60° C Converter -
Bank 1 gen sensor GX10- . Re‐
Sensor 1 signal: • MAF > 30.00; < fer to
300.0 kg/h ⇒ “3.6.39
• Lambda Oxygen Sen‐
value < 0.80 • Catalyst purge sor 1 Before
[-] not active Catalytic
• And Converter
• Integrated air GX10 ,
mass after end
• O2S signal Checking”,
of catalyst purge
rear <= 0.15 page 972 .
>= 0.0 g
V
• Engine speed >
992 RPM
• EGT @ O2S
front > 300; <
841° C
• Injection mode
change (DFI/
MFI) not active
• Integrated air
mass > 40.0 g
• Dynamic lamb‐
da controller
output < 3.0 %
• Dynamic MAF <
0.10 g/rev
• Dynamic engine
speed < 300
RPM
• And
• Second control
loop active:
• Air mass 0.07 –
0.85 g/rev
• Engine speed
608 – 4,512
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2197 Oxygen • Plausibility • O2S front ready • 270.0 s • 2 DCY – Check the
O2 Sensor Sensors check up‐ Oxygen Sen‐
Signal Front stream and • O2S rear ready • Continu‐ sor 2 Before
Biased/ Bank 2 down‐ ous Catalytic
• ECT @ cylinder
Stuck Rationali‐ stream oxy‐ block >= 60° C Converter -
Lean Bank ty Check gen sensor GX11- . Re‐
2 Sensor 1 signal: • MAF > 30.00; < fer to
300.0 kg/h ⇒ “3.6.41
• Lambda Oxygen Sen‐
value > 1.24 • Catalyst purge sor 2 Before
[-] not active Catalytic
• And Converter
• Integrated air GX11 ,
mass after end
• O2S signal Checking”,
of catalyst purge
rear >= 0.82 page 978 .
>= 0.0 g
V
• Engine speed >
992 RPM
• EGT @ O2S
front > 300; <
841° C
• Injection mode
change (DFI/
MFI) not active
• Integrated air
mass > 40.0 g
• Dynamic lamb‐
da controller
output < 3.0 %
• Dynamic air
mass < 0.10 g/
rev
• Dynamic engine
speed < 300
RPM
• And
• Second control
loop active:
• Air mass 0.07 –
0.85 g/rev
• Engine speed
608 – 4,512
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2198 Oxygen • Plausibility • O2S front ready • 270.0 s • 2 DCY – Check the
O2 Sensor Sensors check up‐ Oxygen Sen‐
Signal Front stream and • O2S rear ready • Continu‐ sor 2 Before
Biased/ Bank 2 down‐ ous Catalytic
• ECT @ cylinder
Stuck Rich Rationali‐ stream oxy‐ block >= 60° C Converter -
Bank 2 ty Check gen sensor GX11- . Re‐
Sensor 1 signal: • MAF > 30.00; < fer to
300.0 kg/h ⇒ “3.6.41
• Lambda Oxygen Sen‐
value < 0.80 • Catalyst purge sor 2 Before
[-] not active Catalytic
• And Converter
• Integrated air GX11 ,
mass after end
• O2S signal Checking”,
of catalyst purge
rear <= 0.15 page 978 .
>= 0.0 g
V
• Engine speed >
992 RPM
• EGT @ O2S
front > 300; <
841° C
• Injection mode
change (DFI/
MFI) not active
• Integrated air
mass > 40.0 g
• Dynamic lamb‐
da controller
output < 3.0 %
• Dynamic air
mass < 0.10 g/
rev
• Dynamic engine
speed < 300
RPM
• And
• Second control
loop active:
• Air mass 0.07 –
0.85 g/rev
• Engine speed
608 – 4,512
RPM
– Check the
Cylinder 1
Fuel Injector
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Lambda value 2 - N532- .
tem Di‐ value of cyl‐ vs. modeled Refer to
rect Fuel inder indi‐ lambda value < ⇒ “3.6.25
Injection vidual lamb‐ 0.50 [-] Fuel Injec‐
A/F Im‐ da control < • Cylinder shut off tors (2 [B Cir‐
balance: -10.0 % cuit]), Check‐
Out Of not active ing”,
Range • Canister load <= page 944
Low 0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
• Target fuel
mass, upper
range <= 0.0 –
36.01 mg/rev
• Engine no full
load
• Catalyst heating
not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P219D Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 2 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 2
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injector
Ratio Im‐ Injection vidual lamb‐ ous - N31- . Refer
balance A/F Im‐ da control > • Air mass 0.0 – to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled – Check the
lambda value < Cylinder 2
0.50 [-] Fuel Injector
2 - N533- .
• Cylinder shut off Refer to
not active ⇒ “3.6.25
Fuel Injec‐
• Canister load <= tors (2 [B Cir‐
0.90 [-] cuit]), Check‐
• Integrated air ing”,
mass after high page 944
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P219E Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 3 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 3
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injector
Ratio Im‐ Injection vidual lamb‐ ous - N32- . Refer
balance A/F Im‐ da control > • Air mass 0.0 – to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled – Check the
lambda value < Cylinder 3
0.50 [-] Fuel Injector
2 - N534- .
• Cylinder shut off Refer to
not active ⇒ “3.6.25
Fuel Injec‐
• Canister load <= tors (2 [B Cir‐
0.90 [-] cuit]), Check‐
• Integrated air ing”,
mass after high page 944
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P219F Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 4 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 4
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injector
Ratio Im‐ Injection vidual lamb‐ ous - N33- . Refer
balance A/F Im‐ da control > • Air mass 0.0 – to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled – Check the
lambda value < Cylinder 4
0.50 [-] Fuel Injector
2 - N535- .
• Cylinder shut off Refer to
not active ⇒ “3.6.25
Fuel Injec‐
• Canister load <= tors (2 [B Cir‐
0.90 [-] cuit]), Check‐
• Integrated air ing”,
mass after high page 944
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21A0 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 5 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 5
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injector
Ratio Im‐ Injection vidual lamb‐ ous - N83- . Refer
balance A/F Im‐ da control > • Air mass 0.0 – to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled – Check the
lambda value < Cylinder 5
0.50 [-] Fuel Injector
2 - N536- .
• Cylinder shut off Refer to
not active ⇒ “3.6.25
Fuel Injec‐
• Canister load <= tors (2 [B Cir‐
0.90 [-] cuit]), Check‐
• Integrated air ing”,
mass after high page 944
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21A1 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 6 tem Di‐ value of cyl‐ pressure > 63.0 Cylinder 6
Air-Fuel rect Fuel inder indi‐ kPa • Continu‐ Fuel Injector
Ratio Im‐ Injection vidual lamb‐ ous - N84- . Refer
balance A/F Im‐ da control > • Air mass 0.0 – to
balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.24
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors, Check‐
High RPM ing”,
page 942 .
• Lambda value
vs. modeled – Check the
lambda value < Cylinder 6
0.50 [-] Fuel Injector
2 - N537- .
• Cylinder shut off Refer to
not active ⇒ “3.6.25
Fuel Injec‐
• Canister load <= tors (2 [B Cir‐
0.90 [-] cuit]), Check‐
• Integrated air ing”,
mass after high page 944
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front ready
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Di‐ value of cyl‐ mass, upper
rect Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21CF Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 1 Valves driver volt‐ active CRK Cylinder 1
Injector Open Cir‐ age, lower Fuel Injector
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ 2 - N532- .
Open – 2.21 V active ous Refer to
• Engine speed > ⇒ “3.6.25
• Injector Fuel Injec‐
driver volt‐ 0 RPM
tors (2 [B Cir‐
age, upper • No full load cuit]), Check‐
range ing”,
(hardware • Or page 944 .
values)
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0 ms
• Actuator com‐
manded off
P21D0 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 2 Valves driver volt‐ active CRK Cylinder 2
Injector Open Cir‐ age, lower Fuel Injector
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ 2 - N533- .
Open – 2.21 V active ous Refer to
• Engine speed > ⇒ “3.6.25
• Injector Fuel Injec‐
driver volt‐ 0 RPM
tors (2 [B Cir‐
age, upper • No full load cuit]), Check‐
range ing”,
(hardware • Or page 944 .
values)
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0 ms
• Actuator com‐
manded off
P21D1 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 3 Valves driver volt‐ active CRK Cylinder 3
Injector Open Cir‐ age, lower Fuel Injector
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ 2 - N534- .
Open – 2.21 V active ous Refer to
• Engine speed > ⇒ “3.6.25
• Injector Fuel Injec‐
driver volt‐ 0 RPM
tors (2 [B Cir‐
age, upper • No full load cuit]), Check‐
range ing”,
(hardware • Or page 944 .
values)
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0 ms
• Actuator com‐
manded off
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21D2 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 4 Valves driver volt‐ active CRK Cylinder 4
Injector Open Cir‐ age, lower Fuel Injector
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ 2 - N535- .
Open – 2.21 V active ous Refer to
• Engine speed > ⇒ “3.6.25
• Injector Fuel Injec‐
driver volt‐ 0 RPM
tors (2 [B Cir‐
age, upper • No full load cuit]), Check‐
range ing”,
(hardware • Or page 944 .
values)
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0 ms
• Actuator com‐
manded off
P21D3 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 5 Valves driver volt‐ active CRK Cylinder 5
Injector Open Cir‐ age, lower Fuel Injector
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ 2 - N536- .
Open – 2.21 V active ous Refer to
• Engine speed > ⇒ “3.6.25
• Injector Fuel Injec‐
driver volt‐ 0 RPM
tors (2 [B Cir‐
age, upper • No full load cuit]), Check‐
range ing”,
(hardware • Or page 944 .
values)
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0 ms
• Actuator com‐
manded off
P21D4 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 6 Valves driver volt‐ active CRK Cylinder 6
Injector Open Cir‐ age, lower Fuel Injector
"B" Circuit/ cuit range 1.92 • Fuel cut off not • Continu‐ 2 - N537- .
Open – 2.21 V active ous Refer to
• Engine speed > ⇒ “3.6.25
• Injector Fuel Injec‐
driver volt‐ 0 RPM
tors (2 [B Cir‐
age, upper • No full load cuit]), Check‐
range ing”,
(hardware • Or page 944 .
values)
2.85 – 3.25 • Engine speed <
V 0 RPM
• Injection time >
0 ms
• Actuator com‐
manded off
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21DB Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 1 Valves driver volt‐ active CRK Cylinder 1
Injector Short To age (hard‐ Fuel Injector
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ 2 - N532- .
Low ues) < 1.92 active ous Refer to
– 2.21 V • Engine speed > ⇒ “3.6.25
0 RPM Fuel Injec‐
tors (2 [B Cir‐
• no full load cuit]), Check‐
ing”,
• or page 944 .
• engine speed <
0 [rpm]
• Actuator com‐
manded off
P21DC Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 1 Valves driver cur‐ active CRK Cylinder 1
Injector Short To rent driver Fuel Injector
"B" Circuit Battery stage inter‐ • Fuel cut off not • Continu‐ 2 - N532- .
High Plus nal value active ous Refer to
• Engine speed > ⇒ “3.6.25
• Or Fuel Injec‐
0 RPM
• Power tors (2 [B Cir‐
stage tem‐ • Injection time > cuit]), Check‐
perature 0 ms ing”,
hardware page 944 .
• Actuator com‐
values) > manded on
160 – 200°
C
P21DE Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 2 Valves driver volt‐ active CRK Cylinder 2
Injector Short To age (hard‐ Fuel Injector
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ 2 - N533- .
Low ues) < 1.92 active ous Refer to
– 2.21 V • Engine speed > ⇒ “3.6.25
0 RPM Fuel Injec‐
tors (2 [B Cir‐
• no full load cuit]), Check‐
ing”,
• or page 944 .
• engine speed <
0 [rpm]
• Actuator com‐
manded off
P21DF Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 2 Valves driver cur‐ active CRK Cylinder 2
Injector Short To rent driver Fuel Injector
"B" Circuit Battery stage inter‐ • Fuel cut off not • Continu‐ 2 - N533- .
High Plus nal value active ous Refer to
• Engine speed > ⇒ “3.6.25
• Or Fuel Injec‐
0 RPM
• Power tors (2 [B Cir‐
stage tem‐ • Injection time > cuit]), Check‐
perature 0 ms ing”,
hardware page 944 .
• Actuator com‐
values) > manded on
160 – 200°
C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21E0 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 3 Valves driver volt‐ active CRK Cylinder 3
Injector Short To age (hard‐ Fuel Injector
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ 2 - N534- .
Low ues) < 1.92 active ous Refer to
– 2.21 V • Engine speed > ⇒ “3.6.25
0 RPM Fuel Injec‐
tors (2 [B Cir‐
• no full load cuit]), Check‐
ing”,
• or page 944 .
• engine speed <
0 [rpm]
• Actuator com‐
manded off
P21E1 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 3 Valves driver cur‐ active CRK Cylinder 3
Injector Short To rent driver Fuel Injector
"B" Circuit Battery stage inter‐ • Fuel cut off not • Continu‐ 2 - N534- .
High Plus nal value active ous Refer to
• Engine speed > ⇒ “3.6.25
• Or Fuel Injec‐
0 RPM
• Power tors (2 [B Cir‐
stage tem‐ • Injection time > cuit]), Check‐
perature 0 ms ing”,
hardware page 944 .
• Actuator com‐
values) > manded on
160 – 200°
C
P21E2 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 4 Valves driver volt‐ active CRK Cylinder 4
Injector Short To age (hard‐ Fuel Injector
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ 2 - N535- .
Low ues) < 1.92 active ous Refer to
– 2.21 V • Engine speed > ⇒ “3.6.25
0 RPM Fuel Injec‐
tors (2 [B Cir‐
• no full load cuit]), Check‐
ing”,
• or page 944 .
• engine speed <
0 [rpm]
• Actuator com‐
manded off
P21E3 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 4 Valves driver cur‐ active CRK Cylinder 4
Injector Short To rent driver Fuel Injector
"B" Circuit Battery stage inter‐ • Fuel cut off not • Continu‐ 2 - N535- .
High Plus nal value active ous Refer to
• Engine speed > ⇒ “3.6.25
• Or Fuel Injec‐
0 RPM
• Power tors (2 [B Cir‐
stage tem‐ • Injection time > cuit]), Check‐
perature 0 ms ing”,
hardware page 944 .
• Actuator com‐
values) > manded on
160 – 200°
C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21E4 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 5 Valves driver volt‐ active CRK Cylinder 5
Injector Short To age (hard‐ Fuel Injector
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ 2 - N536- .
Low ues) < 1.92 active ous Refer to
– 2.21 V • Engine speed > ⇒ “3.6.25
0 RPM Fuel Injec‐
tors (2 [B Cir‐
• no full load cuit]), Check‐
ing”,
• or page 944 .
• engine speed <
0 [rpm]
• Actuator com‐
manded off
P21E5 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 5 Valves driver cur‐ active CRK Cylinder 5
Injector Short To rent driver Fuel Injector
"B" Circuit Battery stage inter‐ • Fuel cut off not • Continu‐ 2 - N536- .
High Plus nal value active ous Refer to
• Engine speed > ⇒ “3.6.25
• Or Fuel Injec‐
0 RPM
• Power tors (2 [B Cir‐
stage tem‐ • Injection time > cuit]), Check‐
perature 0 ms ing”,
hardware page 944 .
• Actuator com‐
values) > manded on
160 – 200°
C
P21E6 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 6 Valves driver volt‐ active CRK Cylinder 6
Injector Short To age (hard‐ Fuel Injector
"B" Circuit Ground ware val‐ • Fuel cut off not • Continu‐ 2 - N537- .
Low ues) < 1.92 active ous Refer to
– 2.21 V • Engine speed > ⇒ “3.6.25
0 RPM Fuel Injec‐
tors (2 [B Cir‐
• no full load cuit]), Check‐
ing”,
• or page 944 .
• engine speed <
0 [rpm]
• Actuator com‐
manded off
P21E7 Injection • Injector • Engine stop not • 7,200.0° • 2 DCY – Check the
Cylinder 6 Valves driver cur‐ active CRK Cylinder 6
Injector Short To rent driver Fuel Injector
"B" Circuit Battery stage inter‐ • Fuel cut off not • Continu‐ 2 - N537- .
High Plus nal value active ous Refer to
• Engine speed > ⇒ “3.6.25
• Or Fuel Injec‐
0 RPM
• Power tors (2 [B Cir‐
stage tem‐ • Injection time > cuit]), Check‐
perature 0.0 ms ing”,
hardware page 944 .
• Actuator com‐
values) > manded on
160 – 200°
C
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21F4 Fuel Sys‐ • Adaption • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ value >= mg/rev Fuel Delivery
trol Sys‐ port Fuel 25.0 % • Continu‐ Unit - GX1- .
tem "B" Injection • ECT @ cylinder ous Refer to
Too Lean System block > 70° C ⇒ “3.6.23
Off Idle Too Lean • IAT @ manifold Fuel Delivery
Bank 1 @ Part > -11° C Unit GX1 ,
Load Checking”,
• AAT > -48° C page 940 .
• Lambda set – Check the
point 0.92 – 1.05 fuel pressure
[-] regulator and
residual
• Lambda control pressure.
closed loop inte‐ Refer to ap‐
grated air mass propriate re‐
> 30.0 g pair manual.
• Fuel mass 13.01
– 36.01 mg/rev – Check the
pressure in
• Engine speed the fuel sys‐
704 – 4,960 tem for out of
RPM spec condi‐
tions before
• Ethanol value diagnosing
n.a. the pressure
• Low dynamic sensor. Re‐
conditions: fer to Fuel
System Me‐
• Diff. engine chanical
speed vs. aver‐ Testing in
aged engine ⇒ “3.1 Pre‐
speed for engine liminary
speed dynamic Check”,
detection < 150 page 20 .
RPM
– Check the
• Diff. air mass vs. fuel injectors
averaged air (2 [B circuit]).
mass for load Refer to
dynamic detec‐ ⇒ “3.6.25
tion < 130.01 Fuel Injec‐
mg/rev tors (2 [B Cir‐
• Diff. between cuit]), Check‐
reference and ing”,
actual fuel pres‐ page 944 .
sure, high side
<= 34,777.60 – Check the
kPa Fuel Pres‐
sure Sensor -
• Integrated air G247- . Re‐
mass > 15.0 – fer to
70.0 g ⇒ “3.6.27
Fuel Pres‐
• And sure Sensor
G247 ,
• Evap purge Checking”,
valve closed page 948 .
• Or
– Check intake
• Canister load <= system visu‐
2.0 [-] ally for leaks
(false air).
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge – Check the
valve at max. Oxygen Sen‐
value sor 1 Before
Catalytic
• Or Converter -
• Dependence on GX10- . Re‐
canister purge fer to
min: ⇒ “3.6.39
Oxygen Sen‐
• Lower limit of sor 1 Before
lambda control‐ Catalytic
ler output n.a. Converter
GX10 ,
• Or Checking”,
page 972 .
• Upper limit of
lambda control‐ – Check the
ler output n.a. Oxygen Sen‐
• And sor 1 After
Catalytic
• Evap purge flow Converter -
at min. value GX7- . Refer
to
⇒ “3.6.38
Oxygen Sen‐
sor 1 After
Catalytic
Converter
GX7 , Check‐
ing”,
page 970 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21F5 Fuel Sys‐ • Adaption • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ value <= mg/rev fuel pressure
trol Sys‐ port Fuel -25.0 % • Continu‐ regulator and
tem "B" Injection • ECT @ cylinder ous residual
Too Rich System block > 70° C pressure.
Off Idle Too Rich • IAT @ manifold Refer to ap‐
Bank 1 @ Part > -11° C propriate re‐
Load pair manual.
• AAT > -48° C
– Check the
• lambda set point pressure in
0.92 – 1.05 [-] the fuel sys‐
tem for out of
• Lambda control spec condi‐
closed loop inte‐ tions before
grated air mass diagnosing
> 30.0 g the pressure
• Fuel mass 13.01 sensor. Re‐
– 36.01 mg/rev fer to Fuel
System Me‐
• Engine speed chanical
704 – 4,960 Testing in
RPM ⇒ “3.1 Pre‐
liminary
• Ethanol value Check”,
n.a. page 20 .
• Low dynamic
conditions: – Check the
fuel injectors
• Diff. engine (2 [B circuit]).
speed vs. aver‐ Refer to
aged engine ⇒ “3.6.25
speed for engine Fuel Injec‐
speed dynamic tors (2 [B Cir‐
detection < 150 cuit]), Check‐
RPM ing”,
page 944 .
• Diff. air mass vs.
averaged air – Check the
mass for load Fuel Pres‐
dynamic detec‐ sure Sensor -
tion < 130.01 G247- . Re‐
mg/rev fer to
• Diff. between ⇒ “3.6.27
reference and Fuel Pres‐
actual fuel pres‐ sure Sensor
sure, high side G247 ,
<= 34,777.60 Checking”,
kPa page 948 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge – Check the
valve at max. Oxygen Sen‐
value sor 1 After
Catalytic
• Or Converter -
• Dependence on GX7- . Refer
canister purge to
min: ⇒ “3.6.38
Oxygen Sen‐
• Lower limit of sor 1 After
lambda control‐ Catalytic
ler output n.a. Converter
GX7 , Check‐
• Or ing”,
page 970 .
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21F6 Fuel Sys‐ • Adaption • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ value >= mg/rev Fuel Delivery
trol Sys‐ port Fuel 25.0 % • Continu‐ Unit - GX1- .
tem "B" Injection • ECT @ cylinder ous Refer to
Too Lean System block > 70° C ⇒ “3.6.23
Off Idle Too Lean • IAT @ manifold Fuel Delivery
Bank 2 @ Part > -11° C Unit GX1 ,
Load Checking”,
• AAT > -48° C page 940 .
• lambda set point – Check the
0.92 – 1.05 [-] fuel pressure
regulator and
• Lambda control residual
closed loop inte‐ pressure.
grated air mass Refer to ap‐
> 30.0 g propriate re‐
• Fuel mass 13.01 pair manual.
– 36.01 mg/rev
– Check the
• Engine speed pressure in
704 – 4,960 the fuel sys‐
RPM tem for out of
spec condi‐
• Ethanol value tions before
n.a. diagnosing
• Low dynamic the pressure
conditions: sensor. Re‐
fer to Fuel
• Diff. engine System Me‐
speed vs. aver‐ chanical
aged engine Testing in
speed for engine ⇒ “3.1 Pre‐
speed dynamic liminary
detection < 150 Check”,
RPM page 20 .
• Diff. air mass vs. – Check the
averaged air fuel injectors
mass for load (2 [B circuit]).
dynamic detec‐ Refer to
tion < 130.01 ⇒ “3.6.25
mg/rev Fuel Injec‐
• Diff. between tors (2 [B Cir‐
reference and cuit]), Check‐
actual fuel pres‐ ing”,
sure, high side page 944 .
<= 34,777.60
kPa – Check the
Fuel Pres‐
• Integrated air sure Sensor -
mass > 15.0 – G247- . Re‐
70.0 g fer to
⇒ “3.6.27
• And Fuel Pres‐
sure Sensor
• Evap purge G247 ,
valve closed Checking”,
• Or page 948 .
• Canister load <= – Check intake
2.0 [-] system visu‐
ally for leaks
(false air).
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge – Check the
valve at max. Oxygen Sen‐
value sor 2 Before
Catalytic
• Or Converter -
• Dependence on GX11- . Re‐
canister purge fer to
min: ⇒ “3.6.41
Oxygen Sen‐
• Lower limit of sor 2 Before
lambda control‐ Catalytic
ler output n.a. Converter
GX11 ,
• Or Checking”,
page 978 .
• Upper limit of
lambda control‐ – Check the
ler output n.a. Oxygen Sen‐
• And sor 2 After
Catalytic
• Evap purge flow Converter -
at min. value GX8- . Refer
to
⇒ “3.6.40
Oxygen Sen‐
sor 2 After
Catalytic
Converter
GX8 , Check‐
ing”,
page 976 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21F7 Fuel Sys‐ • Adaption • Air mass > 76.0 • 20.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ value <= mg/rev fuel pressure
trol Sys‐ port Fuel -25.0 % • Continu‐ regulator and
tem "B" Injection • ECT @ cylinder ous residual
Too Rich System block > 70° C pressure.
Off Idle Too Rich • IAT @ manifold Refer to ap‐
Bank 2 @ Part > -11° C propriate re‐
Load pair manual.
• AAT > -48° C
– Check the
• lambda set point fuel injectors
0.92 – 1.05 [-] (2 [B circuit]).
Refer to
• Lambda control ⇒ “3.6.25
closed loop inte‐ Fuel Injec‐
grated air mass tors (2 [B Cir‐
> 30.0 g cuit]), Check‐
• Fuel mass 13.01 ing”,
– 36.01 mg/rev page 944 .
• Engine speed – Check the
704 – 4,960 Fuel Pres‐
RPM sure Sensor -
G247- . Re‐
• Ethanol value fer to
n.a. ⇒ “3.6.27
• Low dynamic Fuel Pres‐
conditions: sure Sensor
G247 ,
• Diff. engine Checking”,
speed vs. aver‐ page 948 .
aged engine
speed for engine – Check the
speed dynamic Oxygen Sen‐
detection < 150 sor 2 Before
RPM Catalytic
Converter -
• Diff. air mass vs. GX11- . Re‐
averaged air fer to
mass for load ⇒ “3.6.41
dynamic detec‐ Oxygen Sen‐
tion < 130.01 sor 2 Before
mg/rev Catalytic
• Diff. between Converter
reference and GX11 ,
actual fuel pres‐ Checking”,
sure, high side page 978 .
<= 34,777.60
kPa – Check the
Oxygen Sen‐
• Integrated air sor 2 After
mass > 15.0 – Catalytic
70.0 g Converter -
GX8- . Refer
• And to
⇒ “3.6.40
• Evap purge Oxygen Sen‐
valve closed sor 2 After
• Or Catalytic
Converter
• Canister load <= GX8 , Check‐
2.0 [-] ing”,
page 976 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Evap purge
valve at max.
value
• Or
• Dependence on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21F8 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ mg/rev Fuel Delivery
trol Sys‐ port Fuel • Adaptive • Continu‐ Unit - GX1- .
tem "B" Injection value >= • ECT @ cylinder ous Refer to
Too Lean System n.a. mg/rev block > 70° C ⇒ “3.6.23
at Idle Too Lean • Case 2: • IAT @ manifold Fuel Delivery
Bank 1 @ Idle > -11° C Unit GX1 ,
• Adaptive Checking”,
value >= • AAT > -48° C page 940 .
0.33 kg/h
• lambda set point – Check the
0.92 – 1.05 [-] fuel pressure
regulator and
• Lambda control residual
closed loop pressure.
• Integrated air Refer to ap‐
mass > 30.0 g propriate re‐
pair manual.
• Vehicle speed <
31 mph – Check the
pressure in
• Ethanol value the fuel sys‐
n.a. tem for out of
• Low dynamic spec condi‐
conditions: tions before
diagnosing
• Diff. engine the pressure
speed vs. aver‐ sensor. Re‐
aged engine fer to Fuel
speed for engine System Me‐
speed dynamic chanical
detection < 150 Testing in
RPM ⇒ “3.1 Pre‐
liminary
• Diff. air mass vs. Check”,
averaged air page 20 .
mass for load
dynamic detec‐ – Check the
tion < 130.01 fuel injectors
mg/rev (2 [B circuit]).
• Diff. between Refer to
reference and ⇒ “3.6.25
actual fuel pres‐ Fuel Injec‐
sure, high side tors (2 [B Cir‐
<= 34,777.60 cuit]), Check‐
kPa ing”,
page 944 .
• Integrated air
mass > 15.0 – – Check the
70.0 g Fuel Pres‐
sure Sensor -
• And G247- . Re‐
• Fuel mass lower fer to
⇒ “3.6.27
range > Fuel Pres‐
5.00...9.01 [mg/ sure Sensor
rev] G247 ,
• Fuel mass upper Checking”,
range < page 948 .
0.00...15.01
[mg/rev] – Check intake
system visu‐
• Engine speed ally for leaks
704...1504 [rpm] (false air).
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Or – Check the
Oxygen Sen‐
• Engine n.a. sor 1 Before
• And Catalytic
Converter -
• Evap purge GX10- . Re‐
valve closed fer to
⇒ “3.6.39
• Or Oxygen Sen‐
sor 1 Before
• Canister load <= Catalytic
2.0 [-] Converter
• Evap purge GX10 ,
valve at max. Checking”,
value page 972 .
• Or – Check the
Oxygen Sen‐
• Depending on sor 1 After
canister purge Catalytic
min: Converter -
• Lower limit of GX7- . Refer
lambda control‐ to
ler output n.a. ⇒ “3.6.38
Oxygen Sen‐
• Or sor 1 After
Catalytic
• Upper limit of Converter
lambda control‐ GX7 , Check‐
ler output n.a. ing”,
• And page 970 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21F9 Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ mg/rev fuel pressure
trol Sys‐ port Fuel • Adaptive • Continu‐ regulator and
tem "B" Injection value <= • ECT @ cylinder ous residual
Too Rich System n.a. mg/rev block > 70° C pressure.
at Idle Too Rich • Case 2: • IAT @ manifold Refer to ap‐
Bank 1 @ Idle > -11° C propriate re‐
• Adaptive pair manual.
value <= • AAT > -48° C
-0.33 kg/h – Check the
• lambda set point pressure in
0.92 – 1.05 [-] the fuel sys‐
tem for out of
• Lambda control spec condi‐
closed loop tions before
• Oil dilution not diagnosing
detected the pressure
sensor. Re‐
• integrated air fer to Fuel
mass > 30.0 g System Me‐
chanical
• Vehicle speed < Testing in
31 mph ⇒ “3.1 Pre‐
• Ethanol value liminary
n.a. Check”,
page 20 .
• Low dynamic
conditions: – Check the
fuel injectors
• Diff. engine (2 [B circuit]).
speed vs. aver‐ Refer to
aged engine ⇒ “3.6.25
speed for engine Fuel Injec‐
speed dynamic tors (2 [B Cir‐
detection < 150 cuit]), Check‐
RPM ing”,
• Diff. air mass vs. page 944 .
averaged air
mass for load – Check the
dynamic detec‐ Fuel Pres‐
tion < 130.01 sure Sensor -
mg/rev G247- . Re‐
fer to
• Diff. between ⇒ “3.6.27
reference and Fuel Pres‐
actual fuel pres‐ sure Sensor
sure, high side G247 ,
<= 34,777.60 Checking”,
kPa page 948 .
• Integrated air – Check the
mass > 15.0 – Oxygen Sen‐
70.0 g sor 1 Before
• And Catalytic
Converter -
• Fuel mass lower GX10- . Re‐
range > 5.00 – fer to
9.01 mg/rev ⇒ “3.6.39
Oxygen Sen‐
• Fuel mass upper sor 1 Before
range < 0.00 – Catalytic
15.01 mg/rev Converter
GX10 ,
• Engine speed Checking”,
704...1504 rpm page 972 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Or – Check the
Oxygen Sen‐
• Engine n.a. sor 1 After
• And Catalytic
Converter -
• Evap purge GX7- . Refer
valve closed to
⇒ “3.6.38
• Or Oxygen Sen‐
sor 1 After
• Canister load <= Catalytic
2.0 [-] Converter
• Evap purge GX7 , Check‐
valve at max. ing”,
value page 970 .
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21FA Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ mg/rev Fuel Delivery
trol Sys‐ port Fuel • Adaptive • Continu‐ Unit - GX1- .
tem "B" Injection value >= • ECT @ cylinder ous Refer to
Too Lean System n.a. mg/rev block > 70° C ⇒ “3.6.23
at Idle Too Lean • Case 2: • IAT @ manifold Fuel Delivery
Bank 2 @ Idle > -11° C Unit GX1 ,
• Adaptive Checking”,
value >= • AAT > -48° C page 940 .
0.33 kg/h
• lambda set point – Check the
0.92 – 1.05 [-] fuel pressure
regulator and
• Lambda control residual
closed loop pressure.
• Integrated air Refer to ap‐
mass > 30.0 g propriate re‐
pair manual.
• Vehicle speed <
31 mph – Check the
pressure in
• Ethanol value the fuel sys‐
n.a. tem for out of
• Low dynamic spec condi‐
conditions: tions before
diagnosing
• Diff. engine the pressure
speed vs. aver‐ sensor. Re‐
aged engine fer to Fuel
speed for engine System Me‐
speed dynamic chanical
detection < 150 Testing in
RPM ⇒ “3.1 Pre‐
liminary
• Diff. air mass vs. Check”,
averaged air page 20 .
mass for load
dynamic detec‐ – Check the
tion < 130.01 fuel injectors
mg/rev (2 [B circuit]).
• Diff. between Refer to
reference and ⇒ “3.6.25
actual fuel pres‐ Fuel Injec‐
sure, high side tors (2 [B Cir‐
<= 34,777.60 cuit]), Check‐
kPa ing”,
page 944 .
• Integrated air
mass > 15.0 – – Check the
70.0 g Fuel Pres‐
sure Sensor -
• And G247- . Re‐
• Fuel mass lower fer to
⇒ “3.6.27
range > Fuel Pres‐
5.00...9.01 [mg/ sure Sensor
rev] G247 ,
• Fuel mass upper Checking”,
range < page 948 .
0.00...15.01
[mg/rev] – Check intake
system visu‐
• Engine speed ally for leaks
704...1504 [rpm] (false air).
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Or – Check the
Oxygen Sen‐
• Engine n.a. sor 2 Before
• And Catalytic
Converter -
• Evap purge GX11- . Re‐
valve closed fer to
⇒ “3.6.41
• Or Oxygen Sen‐
sor 2 Before
• Canister load <= Catalytic
2.0 [-] Converter
• Evap purge GX11 ,
valve at max. Checking”,
value page 978 .
• Or – Check the
Oxygen Sen‐
• Depending on sor 2 After
canister purge Catalytic
min: Converter -
• Lower limit of GX8- . Refer
lambda control‐ to
ler output n.a. ⇒ “3.6.40
Oxygen Sen‐
• Or sor 2 After
Catalytic
• Upper limit of Converter
lambda control‐ GX8 , Check‐
ler output n.a. ing”,
• And page 976 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P21FB Fuel Sys‐ • Case 1: • Air mass > 76.0 • 30.0 s • 2 DCY – Check the
Fuel Con‐ tem Multi‐ mg/rev fuel pressure
trol Sys‐ port Fuel • Adaptive • Continu‐ regulator and
tem "B" Injection value <= • ECT @ cylinder ous residual
Too Rich System n.a. mg/rev block > 70° C pressure.
at Idle Too Rich • Case 2: • IAT @ manifold Refer to ap‐
Bank 2 @ Idle > -11° C propriate re‐
• Adaptive pair manual.
value <= • AAT > -48° C
-0.33 kg/h – Check the
• lambda set point pressure in
0.92 – 1.05 [-] the fuel sys‐
tem for out of
• Lambda control spec condi‐
closed loop tions before
• Oil dilution not diagnosing
detected the pressure
sensor. Re‐
• integrated air fer to Fuel
mass > 30.0 g System Me‐
chanical
• Vehicle speed < Testing in
31 mph ⇒ “3.1 Pre‐
• Ethanol value liminary
n.a. Check”,
page 20 .
• Low dynamic
conditions: – Check the
fuel injectors
• Diff. engine (2 [B circuit]).
speed vs. aver‐ Refer to
aged engine ⇒ “3.6.25
speed for engine Fuel Injec‐
speed dynamic tors (2 [B Cir‐
detection < 150 cuit]), Check‐
RPM ing”,
• Diff. air mass vs. page 944 .
averaged air
mass for load – Check the
dynamic detec‐ Fuel Pres‐
tion < 130.01 sure Sensor -
mg/rev G247- . Re‐
fer to
• Diff. between ⇒ “3.6.27
reference and Fuel Pres‐
actual fuel pres‐ sure Sensor
sure, high side G247 ,
<= 34,777.60 Checking”,
kPa page 948 .
• Integrated air – Check the
mass > 15.0 – Oxygen Sen‐
70.0 g sor 2 Before
• And Catalytic
Converter -
• Fuel mass lower GX11- . Re‐
range > 5.00 – fer to
9.01 mg/rev ⇒ “3.6.41
Oxygen Sen‐
• Fuel mass upper sor 2 Before
range < 0.00 – Catalytic
15.01 mg/rev Converter
GX11 ,
• Engine speed Checking”,
704...1504 rpm page 978 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Or – Check the
Oxygen Sen‐
• Engine n.a. sor 2 After
• And Catalytic
Converter -
• Evap purge GX8- . Refer
valve closed to
⇒ “3.6.40
• Or Oxygen Sen‐
sor 2 After
• Canister load <= Catalytic
2.0 [-] Converter
• Evap purge GX8 , Check‐
valve at max. ing”,
value page 976 .
• Or
• Depending on
canister purge
min:
• Lower limit of
lambda control‐
ler output n.a.
• Or
• Upper limit of
lambda control‐
ler output n.a.
• And
• Evap purge flow
at min. value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2237 Oxygen • Diff. pump • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage ar) ready Oxygen Sen‐
Positive Front (VIP) vs. vir‐ • Continu‐ sor 1 Before
Current Open Cir‐ tual ground • O2S ceramic ous Catalytic
Control cuit voltage temperature > Converter -
Circuit/ Pump (VG) > 1.20 830° C GX10- . Re‐
Open Voltage V • For time >= 17.0 fer to
Bank 1 (VIP) s ⇒ “3.6.39
Sensor 1 • Diff. nernst Oxygen Sen‐
voltage sor 1 Before
(VN) vs. vir‐ Catalytic
tual ground Converter
voltage GX10 ,
(VG) <= Checking”,
1.20 V page 972 .
• And
• Choice of:
• Nernst volt‐
age (VN) >
4.40 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2.35
V
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent driver
stage inter‐
nal value
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00
Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2240 Oxygen • Diff. pump • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage ar) ready Oxygen Sen‐
Positive Front (VIP) vs. vir‐ • Continu‐ sor 2 Before
Current Bank 2 tual ground • O2S ceramic ous Catalytic
Control Open Cir‐ voltage temperature > Converter -
Circuit/ cuit (VG) > 1.20 830° C GX11- . Re‐
Open Pump V • For time >= 17.0 fer to
Bank 2 Voltage s ⇒ “3.6.41
Sensor 1 (VIP) • Diff. nernst Oxygen Sen‐
voltage sor 2 Before
(VN) vs. vir‐ Catalytic
tual ground Converter
voltage GX11 ,
(VG) <= Checking”,
1.20 V page 978 .
• And
• Choice of:
• Nernst volt‐
age (VN) >
4.40 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2.35
V
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent driver
stage inter‐
nal value
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00
Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2243 Oxygen • Diff. pump • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage ar) ready Oxygen Sen‐
Reference Front (VIP) vs. vir‐ • Continu‐ sor 1 Before
Voltage Open Cir‐ tual ground • O2S ceramic ous Catalytic
Circuit/ cuit voltage temperature > Converter -
Open Nernst (VG) <= 830° C GX10- . Re‐
Bank 1 Voltage 1.20 V • For time >= 17.0 fer to
Sensor 1 (VN) s ⇒ “3.6.39
• Diff. nernst Oxygen Sen‐
voltage sor 1 Before
(VN) vs. vir‐ Catalytic
tual ground Converter
voltage GX10 ,
(VG) > 1.20 Checking”,
V page 972 .
• And
• Choice of:
• Nernst volt‐
age (VN) >
4.40 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2.35
V
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent driver
stage inter‐
nal value
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00
Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2247 Oxygen • Diff. pump • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors voltage ar) ready Oxygen Sen‐
Reference Front (VIP) vs. vir‐ • Continu‐ sor 2 Before
Voltage Bank 2 tual ground • O2S ceramic ous Catalytic
Circuit/ Open Cir‐ voltage temperature > Converter -
Open cuit (VG) <= 830° C GX11- . Re‐
Bank 2 Nernst 1.20 V • For time >= 17.0 fer to
Sensor 1 Voltage s ⇒ “3.6.41
(VN) • Diff. nernst Oxygen Sen‐
voltage sor 2 Before
(VN) vs. vir‐ Catalytic
tual ground Converter
voltage GX11 ,
(VG) > 1.20 Checking”,
V page 978 .
• And
• Choice of:
• Nernst volt‐
age (VN) >
4.40 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2.35
V
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent driver
stage inter‐
nal value
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Measure‐
ment
WRAF sen‐
sor label re‐
sistor >
4,644.00
Ohm
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2251 Oxygen • Nernst volt‐ • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors age (VN) > ar) ready Oxygen Sen‐
Negative Front 4.40 V • Continu‐ sor 1 Before
Current Open Cir‐ • O2S ceramic ous Catalytic
Control cuit Virtu‐ • Or temperature > Converter -
Circuit/ al Ground • 830° C GX10- . Re‐
Diff. pump
Open (VG) voltage • For time >= 17.0 fer to
Bank 1 (VIP) vs. vir‐ s ⇒ “3.6.39
Sensor 1 tual ground Oxygen Sen‐
voltage sor 1 Before
(VG) > 2.35 Catalytic
V Converter
GX10 ,
• Diff. pump Checking”,
voltage page 972 .
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent driver
stage inter‐
nal value
• Or
• measure‐
ment O2S
front label
resistor >
4,644.00
Ohm
• And
• Choice of:
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) <=
1.20 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) <=
1.20 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2254 Oxygen • Nernst volt‐ • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors age (VN) > ar) ready Oxygen Sen‐
Negative Front 4.40 V • Continu‐ sor 2 Before
Current Bank 2 • O2S ceramic ous Catalytic
Control Open Cir‐ • Or temperature > Converter -
Circuit/ cuit Virtu‐ • 830° C GX11- . Re‐
Diff. pump
Open al Ground voltage • For time >= 17.0 fer to
Bank 2 (VG) (VIP) vs. vir‐ s ⇒ “3.6.41
Sensor 1 tual ground Oxygen Sen‐
voltage sor 2 Before
(VG) > 2.35 Catalytic
V Converter
GX11 ,
• Diff. pump Checking”,
voltage page 978 .
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.60
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.10
V
• Or
• Pump cur‐
rent driver
stage inter‐
nal value
• Or
• measure‐
ment O2S
front label
resistor >
4,644.00
Ohm
• And
• Choice of:
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) <=
1.20 V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) <=
1.20 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
P2257 Secon‐ • Output volt‐ • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air age (hard‐ Secondary
tem Con‐ Injection ware val‐ • Actuator com‐ • Continu‐ Air Injection
trol "A" Cir‐ Pump ues) < 1.92 manded off ous Pump Relay
cuit Low Relay – 2.21 V - -J299-- /
Short To Secondary
Ground Air Injection
Pump Motor
- V101- . Re‐
fer to
⇒ “3.6.42
Secondary
Air Injection
Pump Relay
J299 / Sec‐
ondary Air In‐
jection Pump
Motor V101 ,
Checking”,
page 982 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2258 Secon‐ • Actuator • Engine running • 1.0 s • 2 DCY – Check the
AIR Sys‐ dary Air tempera‐ Secondary
tem Con‐ Injection ture > 160 – • Actuator com‐ • Continu‐ Air Injection
trol "A" Cir‐ Pump 200° C manded on ous Pump Relay
cuit High Relay - -J299-- /
Short To • Or Secondary
Battery • Output cur‐ Air Injection
Plus rent (hard‐ Pump Motor
ware val‐ - V101- . Re‐
ues) driver fer to
stage inter‐ ⇒ “3.6.42
nal value Secondary
Air Injection
Pump Relay
J299 / Sec‐
ondary Air In‐
jection Pump
Motor V101 ,
Checking”,
page 982 .
P2263 Super‐ • Set point • Engine running • 0.3 s • 2 DCY – Check the
Turbo‐ charger pressure ra‐ Charge Air
charger/ (SC) tio @ super‐ • Supercharger • Continu‐ Pressure
Super‐ Clutch charger > speed <= 0 rpm ous Sensor -
charger Actuator 1.10 • For time >= 30.0 G31- / Intake
Boost Sys‐ functional s Manifold
tem Per‐ check • And Temperature
formance • Actual pres‐ • And Sensor -
sure ratio @ • G72- . Refer
AAT < 256° C to
supercharg‐
er <= 1.00 • ⇒ “3.6.10
Engine speed >
[-] Charge Air
675 rpm Pressure
• For time >= • Air mass > Sensor G31 /
0.0 s 150.00 mg/rev Intake Mani‐
fold Temper‐
ature Sensor
G72 , Check‐
ing”,
page 914 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2270 Oxygen • O2S rear • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors voltage < tions: (FTP75: Oxygen Sen‐
Signal Rear Sig‐ 0.82 V 50.0) s sor 1 After
Biased/ nal • Catalyst monitor Catalytic
Stuck Range • Intrusive lambda modula‐ • Once / Converter -
Lean Bank Check lambda tion request ac‐ DCY GX7- . Refer
1 Sensor 2 ramp lean < tive to
0.84 [-] ⇒ “3.6.38
• Vehicle speed
>= 19 mph Oxygen Sen‐
sor 1 After
• BARO >= 63.0 Catalytic
kPa Converter
GX7 , Check‐
• Catalyst over‐ ing”,
heating protec‐ page 970 .
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated MAF,
catalyst temp.
conditions fulfil‐
led >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• MAF per cylin‐
der per stroke,
lower range >=
70.01 – 120.01
mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• MAF per cylin‐
der per stroke,
upper range <=
460.01 – 560.0
mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Deviation actual
and target MAF
< 60.0 mg/rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated MAF
after dynamic
conditions are
fulfilled > 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated MAF
to start diagno‐
sis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted [%]
• Coasting func‐
tion n.a.
• O2S heater rear
active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve ( closing
time ) < n.a. s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled MAF-
integral > 0.0 [g
• Integrated MAF
per cylinder >=
2.20 – 2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2271 Oxygen • O2S rear • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors voltage > tions: (FTP75: Oxygen Sen‐
Signal Rear Sig‐ 0.15 V 50.0) s sor 1 After
Biased/ nal • Catalyst monitor Catalytic
Stuck Rich Range • Intrusive lambda modula‐ • Once / Converter -
Bank 1 Check lambda tion request ac‐ DCY GX7- . Refer
Sensor 2 ramp lean > tive to
1.16 [-] ⇒ “3.6.38
• Intrusive lambda
ramp request Oxygen Sen‐
active sor 1 After
Catalytic
• Vehicle speed Converter
>= 19 mph GX7 , Check‐
ing”,
• BARO >= 63.0 page 970 .
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated MAF,
catalyst temp.
conditions fulfil‐
led >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• MAF per cylin‐
der per stroke,
lower range >=
70.01 – 120.01
mg/rev
• MAF per cylin‐
der per stroke,
upper range <=
460.01 – 560.0
mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Deviation actual
and target MAF
< 60.0 mg/rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated MAF
after dynamic
conditions are
fulfilled > 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated MAF
to start diagno‐
sis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Coasting func‐
tion n.a.
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time ) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled MAF-
integral > 0.0 [g
• Integrated MAF
per cylinder >=
2.20 – 2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2272 Oxygen • O2S rear • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors voltage < tions: (FTP75: Oxygen Sen‐
Signal Rear 0.82 V 50.0) s sor 2 After
Biased/ Bank 2 • Catalyst monitor Catalytic
Stuck Signal • Intrusive lambda modula‐ • Once / Converter -
Lean Bank Range lambda tion request ac‐ DCY GX8- . Refer
2 Sensor 2 Check ramp lean < tive to
0.84 [-] ⇒ “3.6.40
• Vehicle speed
>= 19 mph Oxygen Sen‐
sor 2 After
• BARO >= 63.0 Catalytic
kPa Converter
GX8 , Check‐
• Catalyst over‐ ing”,
heating protec‐ page 976 .
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated MAF,
catalyst temp.
conditions fulfil‐
led >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
• MAF per cylin‐
der per stroke,
lower range >=
70.01 – 120.01
mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• MAF per cylin‐
der per stroke,
upper range <=
460.01 – 560.0
mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Deviation actual
and target MAF
< 60.0 mg/rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated MAF
after dynamic
conditions are
fulfilled > 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated MAF
to start diagno‐
sis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted
• Coasting func‐
tion n.a.
• O2S heater rear
active
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time ) < n.a. s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled MAF-
integral > 0.0 g
• Integrated MAF
per cylinder >=
2.20 – 2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2273 Oxygen • O2S rear • General condi‐ • 0.0 • 2 DCY – Check the
O2 Sensor Sensors voltage > tions: (FTP75: Oxygen Sen‐
Signal Rear 0.15 V 50.0) s sor 2 After
Biased/ Bank 2 • Catalyst monitor Catalytic
Stuck Rich Signal • Intrusive lambda modula‐ • Once / Converter -
Bank 2 Range lambda tion request ac‐ DCY GX8- . Refer
Sensor 2 Check ramp lean > tive to
1.16 [-] ⇒ “3.6.40
• Intrusive lambda
ramp request Oxygen Sen‐
active sor 2 After
Catalytic
• Vehicle speed Converter
>= 19 mph GX8 , Check‐
ing”,
• BARO >= 63.0 page 976 .
kPa
• Catalyst over‐
heating protec‐
tion not active
• Turbine over‐
heating protec‐
tion not equip‐
ped
• O2S rear ready
• O2S front ready
• ECT @ cylinder
block > 70° C
• IAT @ manifold
> -48° C
• Modeled cata‐
lyst temperature
@ start of diag‐
nosis > 500° C
• Modeled cata‐
lyst temperature
@ during diag‐
nosis 460 – 990°
C
• Diff. between
dynamic and
stationary cata‐
lyst temperature
-292 – 292° C
• Integrated MAF,
catalyst temp.
conditions fulfil‐
led >= 25.0 –
200.0 g
• Modeled EGT @
O2S rear <=
1,300° C
• MAF per cylin‐
der 32.0 – 190.0
kg/h
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• MAF per cylin‐
der per stroke,
lower range >=
70.01 – 120.01
mg/rev
• MAF per cylin‐
der per stroke,
upper range <=
460.01 – 560.0
mg/rev
• And
• Low dynamic
conditions
• Deviation actual
and target en‐
gine speed <
310 RPM
• Deviation actual
and target MAF
< 60.0 mg/rev
• Deviation actual
and target lamb‐
da controller
output < 10.0 %
• And
• Integrated MAF
after dynamic
conditions are
fulfilled > 20.0 g
• Time after a cat‐
alyst purge
phase >= 0.0 s
• O2S rear volt‐
age @ diagno‐
sis start >= 0.60
V
• Integrated MAF
to start diagno‐
sis >= 0.0 g
• Integrated heat
energy >= 500.0
kJ
• Engine speed
992 – 3,008
RPM
• Deviation of
lambda control‐
ler output < 50.0
%
• Proportional
part of secon‐
dary fuel control
loop not calibra‐
ted
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Coasting func‐
tion n.a.
• O2S heater rear
active
• Lambda adapta‐
tion not active
• Valve lift not
equipped
• And
• Depending on
Lambda control:
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop before di‐
agnosis < 0.17
[-]
• Or
• Sum of integral
and proportional
part of secon‐
dary fuel control
loop during diag‐
nosis < 0.25 [-]
• Depending on
canister purge:
• Canister load <=
n.a. [-]
• Evap purge flow
n.a.
• Or
• Canister load
calculation n.a.
• Evap purge flow
n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• Or
• Evap purge n.a.
• Or
• Depending on
canister purge
closing:
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Canister purge
(conditions) n.a.
• Canister purge
valve (closing
time ) < n.a. s
• And
• Choice of:
• Evap purge
valve n.a.
• Or
• Evap purge
valve n.a.
• And
• Modeled MAF-
integral > 0.0 g
• Integrated MAF
per cylinder >=
2.20 – 2.70 kg
• Internal resist‐
ance O2S rear
<= 1,000.0 Ω
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2279 Intake Air • Diff. set • Engine running • 0.0 s • 2 DCY – Check the In‐
MAP/MAF System point MAP take Air Tem‐
- Throttle Rationali‐ upstream • Time after en‐ • Continu‐ perature
Position ty Check supercharg‐ gine start > 10.0 ous Sensor -
Correla‐ Low er vs. meas‐ s G42- / Mani‐
tion ured MAP • Barometric fold Absolute
upstream pressure 63.0 – Pressure
supercharg‐ 105.0 kPa Sensor -
er < -15.0 G71- . Refer
kPa • Engine speed 0 to
– 8,160 RPM ⇒ “3.6.30 In‐
• For time >= take Air Tem‐
5.0 s • IAT @ manifold perature
> 5° C Sensor G42 /
Manifold Ab‐
• ECT @ cylinder solute Pres‐
block > -48° C sure Sensor
• Diff. engine G71 , Check‐
speed vs. fil‐ ing”,
tered engine page 954 .
speed for engine
speed dynamic .
detection < 96
RPM
• Diff. air mass set
point vs. filtered
air mass set
point for load dy‐
namic detection
< 15.01 mg/rev
• Engine speed >
512; < 512 RPM
• Fuel cut off not
active
• Pressure gradi‐
ent @ pressure
sensor up‐
stream super‐
charger
-8,291.80 –
8,291.50 kPa/s
• Gradient super‐
charger boost
pressure
-1,500.0 –
1,500.0 kPa/s
• Engine speed
limitation not ac‐
tive
• Fast throttle
adaptation fin‐
ished
• Throttle actuator
commanded on
• Modeled pres‐
sure quotient >
0.30; <= 1.00 [-]
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2300 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils rent in ON 512 RPM nition Coil 1
Coil "A" Short To state (hard‐ • Continu‐ With Power
Primary Ground ware val‐ • ECT @ cylinder ous Output Stage
Control ues) driver block > -30° C - N70- . Refer
Circuit stage inter‐ • Engine stop not to
Low nal value active ⇒ “3.6.29 Ig‐
nition Coils
With Power
Output
Stage ,
Checking”,
page 952 .
P2301 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils by inactive 512 RPM nition Coil 1
Coil "A" Short To low side • Continu‐ With Power
Primary Battery switch in • Engine stop not ous Output Stage
Control Plus ATIC: active - N70- . Refer
Circuit to
High • Output volt‐ • Actuator com‐
⇒ “3.6.29 Ig‐
age in OFF manded off
nition Coils
state (hard‐ With Power
ware val‐ Output
ues) > 4.95 Stage ,
– 5.285 V Checking”,
page 952 .
• Diagnosis • Engine speed >
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2302 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils age in OFF 512 RPM nition Coil 1
Coil "A" Open Cir‐ state, lower • Continu‐ With Power
Secondary cuit range >= • ECT @ cylinder ous Output Stage
Circuit 1.92 – 2.21 block > -30° C - N70- . Refer
V • Engine stop not to
active ⇒ “3.6.29 Ig‐
• Output volt‐ nition Coils
age in OFF With Power
state, upper Output
range Stage ,
(hardware Checking”,
values) <= page 952 .
2.85 – 3.25
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2303 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils rent in ON 512 RPM nition Coil 2
Coil "B" Short To state (hard‐ • Continu‐ With Power
Primary Ground ware val‐ • ECT @ cylinder ous Output Stage
Control ues) driver block > -30° C - N127- . Re‐
Circuit stage inter‐ • Engine stop not fer to
Low nal value active ⇒ “3.6.29 Ig‐
nition Coils
With Power
Output
Stage ,
Checking”,
page 952 .
P2304 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils by inactive 512 RPM nition Coil 2
Coil "B" Short To low side • Continu‐ With Power
Primary Battery switch in • Engine stop not ous Output Stage
Control Plus ATIC: active - N127- . Re‐
Circuit fer to
High • Output volt‐ • Actuator com‐
⇒ “3.6.29 Ig‐
age in OFF manded off
nition Coils
state (hard‐ With Power
ware val‐ Output
ues) > 4.95 Stage ,
– 5.285 V Checking”,
page 952 .
• Diagnosis • Engine speed >
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2305 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils age in OFF 512 RPM nition Coil 2
Coil "B" Open Cir‐ state, lower • Continu‐ With Power
Secondary cuit range >= • ECT @ cylinder ous Output Stage
Circuit 1.92 – 2.21 block > -30° C - N127- . Re‐
V • Engine stop not fer to
active ⇒ “3.6.29 Ig‐
• Output volt‐ nition Coils
age in OFF With Power
state, upper Output
range Stage ,
(hardware Checking”,
values) <= page 952 .
2.85 – 3.25
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2306 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils rent in ON 512 RPM nition Coil 3
Coil "C" Short To state (hard‐ • Continu‐ With Power
Primary Ground ware val‐ • ECT @ cylinder ous Output Stage
Control ues) driver block > -30° C - N291- . Re‐
Circuit stage inter‐ • Engine stop not fer to
Low nal value active ⇒ “3.6.29 Ig‐
nition Coils
With Power
Output
Stage ,
Checking”,
page 952 .
P2307 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils by inactive 512 RPM nition Coil 3
Coil "C" Short To low side • Continu‐ With Power
Primary Battery switch in • Engine stop not ous Output Stage
Control Plus ATIC: active - N291- . Re‐
Circuit fer to
High • Output volt‐ • Actuator com‐
⇒ “3.6.29 Ig‐
age in OFF manded off
nition Coils
state (hard‐ With Power
ware val‐ Output
ues) > 4.95 Stage ,
– 5.285 V Checking”,
page 952 .
• Diagnosis • Engine speed >
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2308 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils age in OFF 512 RPM nition Coil 3
Coil "C" Open Cir‐ state, lower • Continu‐ With Power
Secondary cuit range >= • ECT @ cylinder ous Output Stage
Circuit 1.92 – 2.21 block > -30° C - N291- . Re‐
V • Engine stop not fer to
active ⇒ “3.6.29 Ig‐
• Output volt‐ nition Coils
age in OFF With Power
state, upper Output
range Stage ,
(hardware Checking”,
values) <= page 952 .
2.85 – 3.25
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2309 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils rent in ON 512 RPM nition Coil 4
Coil "D" Short To state (hard‐ • Continu‐ With Power
Primary Ground ware val‐ • ECT @ cylinder ous Output Stage
Control ues) driver block > -30° C - N292- . Re‐
Circuit stage inter‐ • Engine stop not fer to
Low nal value active ⇒ “3.6.29 Ig‐
nition Coils
With Power
Output
Stage ,
Checking”,
page 952 .
P2310 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils by inactive 512 RPM nition Coil 4
Coil "D" Short To low side • Continu‐ With Power
Primary Battery switch in • Engine stop not ous Output Stage
Control Plus ATIC: active - N292- . Re‐
Circuit fer to
High • Output volt‐ • Actuator com‐
⇒ “3.6.29 Ig‐
age in OFF manded off
nition Coils
state (hard‐ With Power
ware val‐ Output
ues) > 4.95 Stage ,
– 5.285 V Checking”,
page 952 .
• Diagnosis • Engine speed >
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2311 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils age in OFF 512 RPM nition Coil 4
Coil "D" Open Cir‐ state, lower • Continu‐ With Power
Secondary cuit range >= • ECT @ cylinder ous Output Stage
Circuit 1.92 – 2.21 block > -30° C - N292- . Re‐
V • Engine stop not fer to
active ⇒ “3.6.29 Ig‐
• Output volt‐ nition Coils
age in OFF With Power
state, upper Output
range Stage ,
(hardware Checking”,
values) <= page 952 .
2.85 – 3.25
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2312 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils rent in ON 512 RPM nition Coil 5
Coil "E" Short To state (hard‐ • Continu‐ With Power
Primary Ground ware val‐ • ECT @ cylinder ous Output Stage
Control ues) driver block > -30° C - N323- . Re‐
Circuit stage inter‐ • Engine stop not fer to
Low nal value active ⇒ “3.6.29 Ig‐
nition Coils
With Power
Output
Stage ,
Checking”,
page 952 .
P2313 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils by inactive 512 RPM nition Coil 5
Coil "E" Short To low side • Continu‐ With Power
Primary Battery switch in • Engine stop not ous Output Stage
Control Plus ATIC: active - N323- . Re‐
Circuit fer to
High • Output volt‐ • Actuator com‐
⇒ “3.6.29 Ig‐
age in OFF manded off
nition Coils
state (hard‐ With Power
ware val‐ Output
ues) > 4.95 Stage ,
– 5.285 V Checking”,
page 952 .
• Diagnosis • Engine speed >
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2314 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils age in OFF 512 RPM nition Coil 5
Coil "E" Open Cir‐ state, lower • Continu‐ With Power
Secondary cuit range >= • ECT @ cylinder ous Output Stage
Circuit 1.92 – 2.21 block > -30° C - N323- . Re‐
V • Engine stop not fer to
active ⇒ “3.6.29 Ig‐
• Output volt‐ nition Coils
age in OFF With Power
state, upper Output
range Stage ,
(hardware Checking”,
values) <= page 952 .
2.85 – 3.25
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2315 Ignition • Output cur‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils rent in ON 512 RPM nition Coil 6
Coil "F" Short To state (hard‐ • Continu‐ With Power
Primary Ground ware val‐ • ECT @ cylinder ous Output Stage
Control ues) driver block > -30° C - N324- . Re‐
Circuit stage inter‐ • Engine stop not fer to
Low nal value active ⇒ “3.6.29 Ig‐
nition Coils
With Power
Output
Stage ,
Checking”,
page 952 .
P2316 Ignition • Diagnosis • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils by inactive 512 RPM nition Coil 6
Coil "F" Short To low side • Continu‐ With Power
Primary Battery switch in • Engine stop not ous Output Stage
Control Plus ATIC: active - N324- . Re‐
Circuit fer to
High • Output volt‐ • Actuator com‐
⇒ “3.6.29 Ig‐
age in OFF manded off
nition Coils
state (hard‐ With Power
ware val‐ Output
ues) > 4.95 Stage ,
– 5.285 V Checking”,
page 952 .
• Diagnosis • Engine speed >
by inactive 512 RPM
low side
switch in • Engine stop not
ATIC: active
P2317 Ignition • Output volt‐ • Engine speed > • 0.8 s • 2 DCY – Check the Ig‐
Ignition Coils age in OFF 512 RPM nition Coil 6
Coil "F" Open Cir‐ state, lower • Continu‐ With Power
Secondary cuit range >= • ECT @ cylinder ous Output Stage
Circuit 1.92 – 2.21 block > -30° C - N324- . Re‐
V • Engine stop not fer to
active ⇒ “3.6.29 Ig‐
• Output volt‐ nition Coils
age in OFF With Power
state, upper Output
range Stage ,
(hardware Checking”,
values) <= page 952 .
2.85 – 3.25
V
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P23F2 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 1 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 1
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injector
"B" Air- Injection vidual lamb‐ ous 2 - N532- .
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – Refer to
Imbalance balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.25
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors (2 [B Cir‐
High RPM cuit]), Check‐
ing”,
• Lambda value page 944 .
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front valid
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P23F3 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 2 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 2
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injector
"B" Air- Injection vidual lamb‐ ous 2 - N533- .
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – Refer to
Imbalance balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.25
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors (2 [B Cir‐
High RPM cuit]), Check‐
ing”,
• Lambda value page 944 .
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front valid
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P23F4 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 3 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 3
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injector
"B" Air- Injection vidual lamb‐ ous 2 - N534- .
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – Refer to
Imbalance balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.25
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors (2 [B Cir‐
High RPM cuit]), Check‐
ing”,
• Lambda value page 944 .
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front valid
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P23F5 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 4 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 4
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injector
"B" Air- Injection vidual lamb‐ ous 2 - N535- .
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – Refer to
Imbalance balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.25
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors (2 [B Cir‐
High RPM cuit]), Check‐
ing”,
• Lambda value page 944 .
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front valid
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P23F6 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 5 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 5
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injector
"B" Air- Injection vidual lamb‐ ous 2 - N536- .
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – Refer to
Imbalance balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.25
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors (2 [B Cir‐
High RPM cuit]), Check‐
ing”,
• Lambda value page 944 .
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front valid
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P23F7 Fuel Sys‐ • Adaptive • Barometric • 3.0 s • 2 DCY – Check the
Cylinder 6 tem Multi‐ value of cyl‐ pressure > 63.0 Cylinder 6
Injector port Fuel inder indi‐ kPa • Continu‐ Fuel Injector
"B" Air- Injection vidual lamb‐ ous 2 - N537- .
Fuel Ratio A/F Im‐ da control > • Air mass 0.0 – Refer to
Imbalance balance: 10.0 % 1,389.0 mg/rev ⇒ “3.6.25
Out Of • Engine speed Fuel Injec‐
Range 600 – 8,160 tors (2 [B Cir‐
High RPM cuit]), Check‐
ing”,
• Lambda value page 944 .
vs. modeled
lambda value <
0.50 [-]
• Cylinder shut off
not active
• Canister load <=
0.90 [-]
• Integrated air
mass after high
dynamics >= 0.0
g
• Catalyst over‐
heating protec‐
tion not active
• Modeled EGT
upstream Cata‐
lyst <= 1,050° C
• Segment adap‐
tation finished
• ECT @ cylinder
block > 70° C
• Diff. pump volt‐
age (VIP) vs. vir‐
tual ground volt‐
age (VG) < -2.1;
> 2.1 V
• O2S front valid
• Min. injection
time not reached
• Lower limit of
lambda control‐
ler output not
reached
• Upper limit of
lambda control‐
ler output not
reached
• Target fuel
mass, lower
range > 12.99 –
1,389.0 mg/rev
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Adaptive • Target fuel
tem Multi‐ value of cyl‐ mass, upper
port Fuel inder indi‐ range <= 0.0 –
Injection vidual lamb‐ 36.01 mg/rev
A/F Im‐ da control < • Engine no full
balance: -10.0 % load
Out Of
Range • Catalyst heating
Low not active
• Secondary air
injection not ac‐
tive
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2414 Oxygen • Pump cur‐ • O2S front ready • 10.0 s • 2 DCY – Check the
O2 Sensor Sensors rent correc‐ Oxygen Sen‐
Exhaust Front Ra‐ tion (nernst- • Fuel cut off not • Continu‐ sor 1 Before
Sample tionality cell) > 3.6 active ous Catalytic
Error Bank Check mA • Injection mode Converter -
1 Sensor 1 change (DFI/ GX10- . Re‐
MFI) not active fer to
⇒ “3.6.39
• Depending on Oxygen Sen‐
engine state: sor 1 Before
Catalytic
• Engine part load Converter
GX10 ,
• Or Checking”,
• Engine full load page 972 .
• Or
• Engine idle
• For time >= 3.0 s
P2415 Oxygen • Pump cur‐ • O2S front ready • 10.0 s • 2 DCY – Check the
O2 Sensor Sensors rent correc‐ Oxygen Sen‐
Exhaust Front tion (nernst- • Fuel cut off not • Continu‐ sor 2 Before
Sample Bank 2 cell) > 3.6 active ous Catalytic
Error Bank Rationali‐ mA • Injection mode Converter -
2 Sensor 1 ty Check change (DFI/ GX11- . Re‐
MFI) not active fer to
⇒ “3.6.41
• Depending on Oxygen Sen‐
engine state: sor 2 Before
Catalytic
• Engine part load Converter
GX11 ,
• Or Checking”,
• Engine full load page 978 .
• Or
• Engine idle
• For time >= 3.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2440 Secon‐ • Diff. lambda • ECT @ cylinder • 0.02 s • 2 DCY – Check the
AIR Sys‐ dary Air controller @ block @ engine Secondary
tem System closed sec‐ start 5 – 50° C • Once / Air Injection
Switching Stuck ondary air DCY Pump Relay
Valve Open valve with • AAT @ engine - J299- / Sec‐
Stuck running start >= 5° C ondary Air In‐
Open secondary • Time after en‐ jection Pump
Bank 1 air pump vs. gine start >= Motor - -
lambda 22.0 –120.0 s V101-- . Re‐
controller @ fer to
closed sec‐ • Fuel cut off not ⇒ “3.6.42
ondary air active Secondary
valve with‐ Air Injection
out running • O2S front ready Pump Relay
secondary J299 / Sec‐
air pump > • MAF <= ondary Air In‐
20.0 % 2,047.97 kg/h jection Pump
• Air mass (en‐ Motor V101 ,
gine load), lower Checking”,
range >= 0.0 – page 982 .
82.0 mg/rev
– Check the
• Air mass (en‐ combination
gine load), up‐ valve for sec‐
per range <= ondary air in‐
452.0 mg/rev jection. Refer
to appropri‐
• Engine speed, ate repair
lower range >= manual.
800 – 8,160
RPM
• Engine speed,
upper range <=
3,008 RPM
• Additional mass
fuel flow for wall
fuel liquid film
-6.0 – 6.0 mg/rev
• O2S front > 2.0
[-]
• Modeled pres‐
sure quotient <=
1.0 [-]
• AIR system
commanded on
• Low dynamic
conditions
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 220
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 110.0 mg/
rev
• Diff. lambda vs.
averaged lamb‐
da for lambda
dynamic detec‐
tion < 1.10 [-]
• Integrated MAF
> 10.0 g
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2442 Secon‐ • Diff. lambda • ECT @ cylinder • 0.02 s • 2 DCY – Check the
AIR Sys‐ dary Air controller @ block @ engine Secondary
tem System 2 closed sec‐ start 5 – 50° C • Once / Air Injection
Switching Stuck ondary air DCY Pump Relay
Valve Open valve with • AAT @ engine - J299- / Sec‐
Stuck running start >= 5° C ondary Air In‐
Open secondary • Time after en‐ jection Pump
Bank 2 air pump vs. gine start >= Motor - -
lambda 22.0 –120.0 s V101-- . Re‐
controller @ fer to
closed sec‐ • Fuel cut off not ⇒ “3.6.42
ondary air active Secondary
valve with‐ Air Injection
out running • O2S front ready Pump Relay
secondary J299 / Sec‐
air pump > • MAF <= ondary Air In‐
20.0 % 2,047.97 kg/h jection Pump
• Air mass (en‐ Motor V101 ,
gine load), lower Checking”,
range >= 0.0 – page 982 .
82.0 mg/rev
– Check the
• Air mass (en‐ combination
gine load), up‐ valve for sec‐
per range <= ondary air in‐
452.0 mg/rev jection. Refer
to appropri‐
• Engine speed, ate repair
lower range >= manual.
800 – 8,160
RPM
• Engine speed,
upper range <=
3,008 RPM
• Additional mass
fuel flow for wall
fuel liquid film
-6.0 – 6.0 mg/rev
• O2S front > 2.0
[-]
• Modeled pres‐
sure quotient <=
1.0 [-]
• AIR system
commanded on
• Low dynamic
conditions
• Diff. engine
speed vs. aver‐
aged engine
speed for engine
speed dynamic
detection < 220
RPM
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. air mass vs.
averaged air
mass for load
dynamic detec‐
tion < 110.0 mg/
rev
• Diff. lambda vs.
averaged lamb‐
da for lambda
dynamic detec‐
tion < 1.10 [-]
• Integrated MAF
> 10.0 g
– Check the
Low Fuel
Pressure
Sensor -
G410- . Re‐
fer to
⇒ “3.6.36
Low Fuel
Pressure
Sensor
G410 ,
Checking”,
page 965 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2540 Fuel Sys‐ • Depending • Engine warm-up • 1.0 s • 2 DCY – Check the
Low Pres‐ tem Pres‐ on Multiport not active pressure in
sure Fuel sure Sen‐ Fuel Injec‐ • Continu‐ the fuel sys‐
System sor, Low tion: • Catalyst heating ous tem for out of
Sensor Pressure not active spec condi‐
Circuit Side Ra‐ • Actual and tions before
Range/ tionality adapted I- • Engine no full
diagnosing
part of elec‐ load
Perform‐ Check the pressure
ance High tric fuel • Lambda control sensor.
pump con‐ active
troller – Check the
(PWM sig‐ • Catalyst over‐ pressure in
nal) < -20.0 heating protec‐ the fuel sys‐
% tion not active tem for out of
• Or spec condi‐
• Catalyst purge tions before
not active
• Diff. fuel diagnosing
pressure • Lambda control the pressure
set point vs. closed loop sensor. Re‐
actual fuel fer to Fuel
pressure < • Canister load <= System Me‐
-19.90 kPa 2.00 [-] chanical
Testing in
• And • Diff. actual fuel ⇒ “3.1 Pre‐
mass set point liminary
• Lambda vs. filtered fuel Check”,
controller mass set point < page 20 .
included 7.50 mg/rev
correction
• Time after en‐ – Check the
and adap‐
gine start > 15.0 Low Fuel
tion > 20.0
s Pressure
% Sensor -
• For time >= • ECT @ cylinder G410- . Re‐
15.0 s block -48° C fer to
⇒ “3.6.36
• And • And Low Fuel
Pressure
• Depending • MFI part of injec‐
Sensor
on high ted fuel >= 0.70
[-] G410 ,
pressure Checking”,
Direct Fuel • page 965 .
Fuel mass set
Injection: point for low
• Actual and pressure-part
adapted I- 3.01 – 45.00 mg/
part of elec‐ rev
tric fuel
pump con‐ • For time >= 3.5 s
troller • And
(PWM sig‐
nal) < • Fuel mass set
-12.50 % point for low
pressure-part
• Or 3.01 – 50.00 mg/
rev
• Diff. fuel
pressure • For time >= 3.5 s
set point vs.
actual fuel
pressure <
-19.90 kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Lambda
controller
included
correction
and adap‐
tion < 12.50
%
• For time >=
15.0 s
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
Fuel Sys‐ • Depending
tem Pres‐ on Multiport
sure Sen‐ Fuel Injec‐
sor, Low tion:
Pressure
Side Ra‐ • Actual and
tionality adapted I-
Check part of elec‐
Low tric fuel
pump con‐
troller
(PWM sig‐
nal) > 28.0
%
• Or
• Diff. fuel
pressure
set point vs.
actual fuel
pressure >
49.88 kPa
• And
• Lambda
controller
included
correction
and adap‐
tion < -20.0
%
• For time >=
10.0 s
• And
• Depending
on high
pressure
Direct Fuel
Injection:
• Actual and
adapted I-
part of elec‐
tric fuel
pump con‐
troller
(PWM sig‐
nal) > 24.90
%
• Or
• Diff. fuel
pressure
set point vs.
actual fuel
pressure >
49.88 kPa
• And
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Lambda
controller
included
correction
and adap‐
tion < 12.50
%
• For time >=
15.0 s
– Check the
pressure in
the fuel sys‐
tem for out of
spec condi‐
tions before
diagnosing
the pressure
sensor. Re‐
fer to Fuel
System Me‐
chanical
Testing in
⇒ “3.1 Pre‐
liminary
Check”,
page 20 .
– Check the
Low Fuel
Pressure
Sensor -
G410- . Re‐
fer to
⇒ “3.6.36
Low Fuel
Pressure
Sensor
G410 ,
Checking”,
page 965 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2579 Super‐ • Ratio be‐ • Supercharger • 0.5 s • 2 DCY – Check the
Turbo‐ charger tween su‐ clutch closed >= Turbocharg‐
charger/ Speed percharger 0.5 s • Continu‐ er Speed
Super‐ Sensor speed vs. ous Sensor 1 -
charger Rationali‐ engine • Engine speed > G688- . Re‐
Speed ty Check speed < 0.0 700 RPM fer to
Sensor "A" [-] • Gradient engine ⇒ “3.6.46
Circuit speed -992.0 – Turbocharg‐
Range/ • Or er Speed
2,016.0 rpm/s
Perform‐ • Ratio be‐ Sensor 1
ance tween su‐ G688 ,
percharger Checking”,
speed vs. page 990 .
engine
speed >
2.75 [-]
P2580 Super‐ • Super‐ • Engine speed > • 0.5 s • 2 DCY – Check the
Turbo‐ charger charger 800 RPM Turbocharg‐
charger/ Speed speed sen‐ • Continu‐ er Speed
Super‐ Sensor sor output • Engine speed ous Sensor 1 -
charger Signal frequency < -704.0 – 704.0 G688- . Re‐
Speed Check 2.0 Hz rpm/s fer to
Sensor "A" • ECT @ cylinder ⇒ “3.6.46
Circuit block > 0° C Turbocharg‐
Low er Speed
• Supercharger Sensor 1
MAF > 40.0 kg/h G688 ,
Checking”,
page 990 .
P25E9 Super‐ • Ratio be‐ • Supercharger • 0.8 s • 2 DCY – Check the
Super‐ charger tween su‐ clutch closed Compressor
charger (SC) percharger commanded on • Continu‐ Magnetic
Discon‐ Clutch speed vs. ous Clutch -
nect Actuator engine • Gradient of en‐ N421- . Refer
Clutch Function‐ speed < gine speed < to
Stuck al Check 2.20 [-] 4,064.0 rpm/s ⇒ “3.6.12
Open Stuck • Engine speed > Compressor
Open 140 RPM Magnetic
Clutch
• For time > 0.3 s N421 ,
Checking”,
page 918 .
P25EA Super‐ • Ratio be‐ • Supercharger • 0.5 s • 2 DCY – Check the
Super‐ charger tween su‐ clutch open Compressor
charger (SC) percharger commanded on • Continu‐ Magnetic
Discon‐ Clutch speed vs. ous Clutch -
nect Actuator engine • Gradient of en‐ N421- . Refer
Clutch Function‐ speed > gine speed < to
Stuck al Check 2.10 [-] 1,504.0 RPM/s ⇒ “3.6.12
Closed Stuck • Engine speed > Compressor
Close 140 RPM Magnetic
Clutch
• For time > 49.0 s N421 ,
Checking”,
page 918 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P25EB Super‐ • SC clutch • Actuator com‐ • 2.0 s • 2 DCY – Check the
Super‐ charger actuator manded off Compressor
charger (SC) voltage 2.0 • Continu‐ Magnetic
Discon‐ Clutch – 3.0 V ous Clutch -
nect Actuator N421- . Refer
Clutch Cir‐ Open Cir‐ to
cuit cuit ⇒ “3.6.12
Range/ Compressor
Perform‐ Magnetic
ance Clutch
N421 ,
Checking”,
page 918 .
P25EC Super‐ • SC clutch • Actuator com‐ • 2.0 s • 2 DCY – Check the
Super‐ charger actuator manded off Compressor
charger (SC) voltage < • Continu‐ Magnetic
Discon‐ Clutch 2.0 V ous Clutch -
nect Actuator N421- . Refer
Clutch Cir‐ Short To to
cuit Low Ground ⇒ “3.6.12
Compressor
Magnetic
Clutch
N421 ,
Checking”,
page 918 .
P25ED Super‐ • SC clutch • Actuator com‐ • 2.0 s • 2 DCY – Check the
Super‐ charger actuator manded on Compressor
charger (SC) current driv‐ • Continu‐ Magnetic
Discon‐ Clutch er stage in‐ ous Clutch -
nect Actuator ternal value N421- . Refer
Clutch Cir‐ Short To to
cuit High Battery ⇒ “3.6.12
Plus Compressor
Magnetic
Clutch
N421 ,
Checking”,
page 918 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2610 Engine • Difference • Monitor Entry • 10.0 ms • 2 DCY – Replace the
ECM/PCM Off Time between Conditions: faulty Engine
Engine Off Rationali‐ engine-off • Once / Control Mod‐
Timer Per‐ ty Check time and • ECM keep alive DCY ule . Refer to
formance ECM keep time active appropriate
alive-time > • Delay time >= repair man‐
12.0 s 1.0 s ual.
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2626 Oxygen • Case 1: • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors ar) ready Oxygen Sen‐
Pumping Front • measure‐ • Once / sor 1 Before
Current Open Cir‐ ment O2S • O2S ceramic DCY Catalytic
Trim Cir‐ cuit front label temperature > Converter -
cuit/Open Nernst resistor > 830° C GX10- . Re‐
Bank 1 Voltage 4644.0 Ω fer to
• For time >= 17.0
Sensor 1 (VN) • And s ⇒ “3.6.39
Oxygen Sen‐
• Choice of: sor 1 Before
Catalytic
• Diff. pump Converter
voltage GX10 ,
(VIP) vs. vir‐ Checking”,
tual ground page 972 .
voltage
(VG) <=
1.20 V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
• Case 2:
• Nernst volt‐
age (VN) >
4.4 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2,35
V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.6 V
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.1
V
• Or
• Pump cur‐
rent driver
stage inter‐
nal value
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2629 Oxygen • Case 1: • O2S front (line‐ • 1.5 s • 2 DCY – Check the
O2 Sensor Sensors ar) ready Oxygen Sen‐
Pumping Front • measure‐ • Once / sor 2 Before
Current Bank 2 ment O2S • O2S ceramic DCY Catalytic
Trim Cir‐ Open Cir‐ front label temperature > Converter -
cuit/Open cuit resistor > 830° C GX11- . Re‐
Bank 2 Nernst 4644.0 Ω fer to
• For time >= 17.0
Sensor 1 Voltage • And s ⇒ “3.6.41
(VN) Oxygen Sen‐
• Choice of: sor 2 Before
Catalytic
• Diff. pump Converter
voltage GX11 ,
(VIP) vs. vir‐ Checking”,
tual ground page 978 .
voltage
(VG) <=
1.20 V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.20
V
• Case 2:
• Nernst volt‐
age (VN) >
4.4 V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) > 2,35
V
• Or
• Diff. pump
voltage
(VIP) vs. vir‐
tual ground
voltage
(VG) < -2.35
V
• Or
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) > 1.6 V
• Or
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
• Diff. nernst
voltage
(VN) vs. vir‐
tual ground
voltage
(VG) < -0.1
V
• Or
• Pump cur‐
rent driver
stage inter‐
nal value
P2AB3 Cold • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the In‐
Cold Start Start age > 1.76 ded off take Mani‐
Intake Monitor‐ V • Continu‐ fold Runner
Manifold ing Intake • Time after en‐ ous Control
Runner Manifold • For time >= gine start > 3.0 s Valve -
Control Runner 4.0 s N316- . Refer
• Catalyst heating
Stuck Control active to
Open (IMRC) ⇒ “3.6.31 In‐
Bank 1 Actuator • And take Mani‐
stuck fold Runner
open • Idle active Control
• Or Valve N316 ,
Checking”,
• Part load active page 956 .
P2AB4 Cold • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the In‐
Cold Start Start age > 1.76 ded off take Mani‐
Intake Monitor‐ V • Continu‐ fold Runner
Manifold ing Intake • Time after en‐ ous Control
Runner Manifold • For time >= gine start > 3.0 s Valve -
Control Runner 4.0 s N316- . Refer
• Catalyst heating
Stuck Control active to
Open (IMRC) ⇒ “3.6.31 In‐
Bank 2 Actuator • And take Mani‐
2 stuck fold Runner
open • Idle active Control
• Or Valve N316 ,
Checking”,
• Part load active page 956 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
P2AB5 Cold • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the In‐
Cold Start Start age < 2.71 ded on take Mani‐
Intake Monitor‐ V • Continu‐ fold Runner
Manifold ing Intake • Time after en‐ ous Control
Runner Manifold • For time >= gine start > 3.0 s Valve -
Control Runner 4.0 s N316- . Refer
• Catalyst heating
Stuck Control active to
Closed (IMRC) ⇒ “3.6.31 In‐
Bank 1 Actuator • And take Mani‐
stuck fold Runner
close • Idle active Control
Valve N316 ,
• Or Checking”,
• Part load active page 956 .
P2AB6 Cold • Signal volt‐ • Flap comman‐ • 0.2 s • 2 DCY – Check the In‐
Cold Start Start age < 2.71 ded on take Mani‐
Intake Monitor‐ V • Continu‐ fold Runner
Manifold ing Intake • Time after en‐ ous Control
Runner Manifold • For time >= gine start > 3.0 s Valve -
Control Runner 4.0 s N316- . Refer
• Catalyst heating
Stuck Control active to
Closed (IMRC) ⇒ “3.6.31 In‐
Bank 2 Actuator • And take Mani‐
2 stuck fold Runner
close • Idle active Control
Valve N316 ,
• Or Checking”,
• Part load active page 956
U0080 FlexRay: • FlexRay • Time after igni‐ • 0.4 s • 2 DCY – Check the
Vehicle Power‐ lost syn‐ tion on 0.5 s terminal re‐
Communi‐ train chroniza‐ • Continu‐ sistance of
cation Bus commu‐ tion trans‐ ous the CAN-
F nication mitting and Bus. Refer to
check receiving no ⇒ “3.6.8
message CAN-Bus
Terminal Re‐
sistance,
Checking”,
page 910 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
U013C Accelera‐ • Received • 0.1 s • 2 DCY – Check the
Lost Com‐ tor Pedal message, terminal re‐
munica‐ Position no mes‐ • Continu‐ sistance of
tion With (APP) sage ous the CAN-
Accelera‐ Sensor 1 Bus. Refer to
tor Pedal commu‐ ⇒ “3.6.8
Module nication CAN-Bus
with APP Terminal Re‐
Sensor 1 sistance,
Checking”,
page 910 .
Accelera‐ • Received • 0.1 s • 2 DCY – Check the
tor Pedal message, terminal re‐
Position no mes‐ • Continu‐ sistance of
(APP) sage ous the CAN-
Sensor 2 Bus. Refer to
commu‐ ⇒ “3.6.8
nication CAN-Bus
with APP Terminal Re‐
Sensor 2 sistance,
Checking”,
page 910 .
U043D Accelera‐ • Received • 0.1 s • 2 DCY – Check the
Invalid Da‐ tor Pedal data im‐ terminal re‐
ta Re‐ Position plausible • Continu‐ sistance of
ceived (APP) message ous the CAN-
From Ac‐ Sensor 1 Bus. Refer to
celerator commu‐ • Received • 0.2 s ⇒ “3.6.8
Pedal nication data im‐ CAN-Bus
Module with APP plausible • Continu‐ Terminal Re‐
Sensor 1 message ous sistance,
Checking”,
page 910 .
U043D Accelera‐ • Received • 0.2 s • 2 DCY – Check the
Invalid Da‐ tor Pedal data im‐ terminal re‐
ta Re‐ Position plausible • Continu‐ sistance of
ceived (APP) message ous the CAN-
From Ac‐ Sensor 2 Bus. Refer to
celerator commu‐ • 0.1 s ⇒ “3.6.8
Pedal nication CAN-Bus
Module with APP • Continu‐ Terminal Re‐
Sensor 2 ous sistance,
Checking”,
page 910 .
U060B Manifold • Received • 0.5 s • 2 DCY – Check the
Lost Com‐ Absolute message terminal re‐
munica‐ Pressure no mes‐ • Continu‐ sistance of
tion With (MAP) sage ous the CAN-
Turbo‐ Sensor Bus. Refer to
charger/ commu‐ ⇒ “3.6.8
Super‐ nication CAN-Bus
charger with MAP Terminal Re‐
Boost sistance,
Sensor "A" Checking”,
page 910 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
U060C Manifold • Received • 0.5 s • 2 DCY – Check the
Lost Com‐ Absolute message terminal re‐
munica‐ Pressure no mes‐ • Continu‐ sistance of
tion With (MAP) sage ous the CAN-
Turbo‐ Sensor 2 Bus. Refer to
charger/ commu‐ ⇒ “3.6.8
Super‐ nication CAN-Bus
charger with MAP Terminal Re‐
Boost 2 sistance,
Sensor "B" Checking”,
page 910 .
U0101 COM: • Received • Time after igni‐ • 0.5 s • 2 DCY – Check the
Lost Com‐ Trans‐ message tion on 0.5 s terminal re‐
munica‐ mission from TCM, • Continu‐ sistance of
tion with Control no mes‐ ous the CAN-Bus
TCM Module sage between the
(TCM) Engine Con‐
Commu‐ trol Module -
nication J623- and
With TCM the Trans‐
mission Con‐
trol Module -
J217- . Refer
to
⇒ “3.6.9
CAN-Bus
Terminal Re‐
sistance,
Powertrain,
Checking”,
page 912 .
U0121 COM: • Received • Time after igni‐ • 0.5 s • 2 DCY – Check the
Lost Com‐ Brake message tion on 0.5 s terminal re‐
munica‐ System from TCS, • Continu‐ sistance of
tion With Control no mes‐ ous the CAN-
Anti-Lock Module sage Bus. Refer to
Brake Sys‐ (BSCM) ⇒ “3.6.8
tem (ABS) Commu‐ CAN-Bus
Control nication Terminal Re‐
Module With sistance,
BSCM Checking”,
page 910 .
U0140 COM: • Received • Time after igni‐ • 2.0 s • 2 DCY – Check the
Lost Com‐ Body Message, tion on 0.5 s terminal re‐
munica‐ Control no mes‐ • Continu‐ sistance of
tion With Module sage ous the CAN-
Body Con‐ (BCM) Bus. Refer to
trol Mod‐ Commu‐ ⇒ “3.6.8
ule nication CAN-Bus
With Terminal Re‐
BCM sistance,
Checking”,
page 910 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
U0141 COM: • Message, • Time after igni‐ • 1.0 s • 2 DCY – Check the
Lost Com‐ Body no mes‐ tion on 500.0 ms terminal re‐
munica‐ Control sage • Continu‐ sistance of
tion With Module 2 ous the CAN-
Body Con‐ (BCM) Bus. Refer to
trol Mod‐ Commu‐ ⇒ “3.6.8
ule "A" nication CAN-Bus
With Terminal Re‐
BCM 2 sistance,
Checking”,
page 910 .
U0155 COM: In‐ • Message, • Time after igni‐ • 5.0 s • 2 DCY – Check the
Lost Com‐ strument no mes‐ tion on 0.5 s terminal re‐
munica‐ Panel sage • Continu‐ sistance of
tion With Cluster ous the CAN-
Instrument (IPC) Bus. Refer to
Panel Commu‐ ⇒ “3.6.8
Cluster nication CAN-Bus
(IPC) Con‐ With IPC Terminal Re‐
trol Mod‐ sistance,
ule Checking”,
page 910 .
U0302 COM: • Received A/ • Time after igni‐ • 5.0 s • 2 DCY – Check the
Software Trans‐ T vehicle tion on 0.5 s terminal re‐
Incompati‐ mission data from • Continu‐ sistance of
bility With Control TCM signal ous the CAN-Bus
Transmis‐ Module between the
sion Con‐ (TCM) Transmis‐
trol Mod‐ Commu‐ sion Control
ule nication Module -
With TCM J217- and
the Engine
Control Mod‐
ule - J623- .
Refer to
⇒ “3.6.9
CAN-Bus
Terminal Re‐
sistance,
Powertrain,
Checking”,
page 912 .
U0322 COM: • Ambient • Time after igni‐ • 2.0 s • 2 DCY – Check the
Software Gateway tempera‐ tion on > 0.1 s terminal re‐
Incompati‐ Commu‐ ture sensor • Continu‐ sistance of
bility With nication coding ous the CAN-
Body Con‐ With monitoring Bus. Refer to
trol Mod‐ Gateway failure ⇒ “3.6.8
ule CAN-Bus
Terminal Re‐
sistance,
Checking”,
page 910 .
U0415 Vehicle • Vehicle • 0.1 s • 2 DCY – Check the
Invalid Da‐ Speed speed > 203 vehicle
ta Re‐ Rationali‐ mph • Continu‐ speed signal.
ceived ty Check ous Refer to
From Anti- High ⇒ “3.6.47
Lock Vehicle
Brake Sys‐ Speed Sig‐
tem (ABS) nal, Check‐
Control ing”,
Module page 992 .
DTC / De‐ Monitor Malfunction Secondary Param‐ Monitoring MIL Illumina‐ Component Di‐
scription Strategy Criteria and eters with Enable Time Length tion agnostic Proce‐
Descrip‐ Threshold Val‐ Conditions dure
tion ue
COM: • Received • Time after igni‐ • 0.5 s
Brake data from tion on 0.5 s
System TCS, im‐ • Continu‐
Control plausible ous
Module message
(BSCM)
Commu‐ • Received • 0.06 s
nication data from
With TCS signal • Continu‐
BSCM out of valid ous
range
U0422 COM: • Ambient • Time after igni‐ • 3.0 s • 2 DCY – Check the
Invalid Da‐ Gateway tempera‐ tion on > 0.1 s terminal re‐
ta Re‐ Commu‐ ture value • Continu‐ sistance of
ceived nication (initializa‐ • Engine running ous the CAN-
From Body With tion) failure Bus. Refer to
Control Gateway ⇒ “3.6.8
Module CAN-Bus
Terminal Re‐
sistance,
Checking”,
page 910 .
U0423 COM: In‐ • Received • Time after igni‐ • 3.0 s • 2 DCY – Check the
Invalid Da‐ strument data from tion on 0.5 s terminal re‐
ta Re‐ Panel IPC, signal • Continu‐ sistance of
ceived Cluster out of valid ous the CAN-
From In‐ (IPC) range Bus. Refer to
strument Commu‐ ⇒ “3.6.8
Panel nication CAN-Bus
Cluster With IPC Terminal Re‐
Control sistance,
Module Checking”,
page 910 .
U0431 COM: • Received • Time after igni‐ • 1.0 s • 2 DCY – Check the
Invalid Da‐ Body data from tion on 500.0 ms terminal re‐
ta Re‐ Control BCM 2 im‐ • Continu‐ sistance of
ceived Module 2 plausible ous the CAN-
From Body (BCM) message Bus. Refer to
Control Commu‐ ⇒ “3.6.8
Module nication CAN-Bus
"A" With Terminal Re‐
BCM 2 sistance,
Checking”,
page 910 .
U1103 ECM: • Production • Vehicle speed < • 0.01 s • 1 DCY – Vehicle in
Production Produc‐ mode active 3 mph production
Mode Ac‐ tion Mode • Continu‐ mode. Refer
tive Function • Max trip mileage ous to appropri‐
Monitor‐ since initial vehi‐ ate repair
ing: Mode cle start-up < manual for
Change 62.15 miles resolution.
• During ECM Note the
keep alive-time mode can be
after ignition off deactivated
with a factory
• Engine speed 0 scan tool or
RPM will automati‐
cally turn off
• For hybrid: after vehicle
accumulates
• Drive motor off the first 100
km of driving.
• Monitoring
of the DN
reset line
failed
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Plausibility • Hardware • Peripheral
check doesn't re‐ clock active
port any on
error al‐
though the • And
peripheral • Delay time
clock is passed
switched
off
• Or
• Peripheral
is switched
on
• And
• There are
hardware
error re‐
ports for at
least two
cycles
• Failure in
program
flow con‐
trol
• Software • SW - or
check configura‐
tion fault in
WDOG
SW-Modul
• Plausibility • An ASIC
check status fail‐
ure has
been de‐
tected
• A moni‐
tored mod‐
ule status
failure has
been de‐
tected
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• RAM ECC • ECC test • Failed
monitoring,
RAM ECC
interrupt
monitoring,
ROM ECC
monitoring
• Dynamic
bypass to
ground
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Current too • >= 50.0 +
high 170.0 mA
• >= Calcu‐
lated lim‐
its, de‐
pending on
incoming
current
gradient
mA
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P0667 Control • With only • Number of • >1 • < • 2 DCY
Module one defec‐ defective 300.0
Internal tive sensor, tempera‐ s
Tempera‐ the trans‐ ture sen‐
ture Sen‐ mission sor signals
sor "A" uses one of
Range/ the remain‐
Perform‐ ing sensor
ance signals as
substitute
value and is
therefore
fully func‐
tional (no
MIL illumi‐
nation and
fault code
storage).
The moni‐
toring of the
3 sensors is
described
below. If at
least one of
the descri‐
bed moni‐
toring strat‐
egies for
each sen‐
sor detects
a malfunc‐
tion, the re‐
spective
sensor is
considered
defective. If
more than
one temper‐
ature sen‐
sor is defect
a fault is
stored and
the MIL is il‐
luminated.
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Circuit con‐ • Voltage at • > 4.7 V
tinuity sensor
plus pin (U • < 0.508 V
pin hi) • > 0.423 V
• Voltage at • < 0.005 V
sensor
plus pin (U • > 4.512 V
pin hi)
• < 0.135 V
• Voltage at
sensor mi‐ • > 15.5
nus pin (U • < 10
pin lo)
• Voltage at
sensor mi‐
nus pin (U
pin lo)
• Difference
voltage at
sensor
pins (U
sensor)
• Difference
voltage at
sensor
pins (U
sensor)
• Resistor
ratio (U
supply – U
sensor) / U
pin lo
• Resistor
ratio (U
supply – U
sensor) / U
pin lo
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Oil temper‐ • > 30° C • Engine
ature value speed or in‐
and chip 1 put speed >
tempera‐ 400 RPM
ture value
and oil • And >= 300.0
tempera‐ s
ture value
and chip 2
tempera‐
ture value
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Rationality • Absolute • > 10° C • No failure de‐ • 300.0
check differen‐ tected in oth‐ s
ces be‐ • > 15° C er chip tem‐
tween • > 30° C perature
Chip 1 and sensor moni‐
Chip 2 tors
tempera‐
ture value • No failure de‐
tected in in‐
• And put speed
signal and
• In thermo‐ engine
dynamic speed signal
stable con‐
ditions: • Engine
speed or in‐
• Absolute put speed >
differen‐ 400 RPM
ces be‐
tween: • And >= 300.0
s
• Oil temper‐
ature value
and chip 1
tempera‐
ture value
• In thermo‐
dynamic
stable con‐
ditions:
• Absolute
differen‐
ces be‐
tween:
• Oil temper‐
ature value
and chip 1
tempera‐
ture value
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Rationality • Absolute • > 10° C • No failure de‐ • 300.0
check differen‐ tected in oth‐ s
ces be‐ • > 15° C er chip tem‐
tween • > 30° C perature
Chip 1 and sensor moni‐
Chip 2 tors
tempera‐
ture value • No failure de‐
tected in in‐
• And put speed
signal and
• In thermo‐ engine
dynamic speed signal
stable con‐
ditions: • Engine
speed or in‐
• Absolute put speed >
differen‐ 400 RPM
ces be‐
tween: • And >= 300.0
s
• Oil temper‐
ature value
and chip 2
tempera‐
ture value
• In thermo‐
dynamic
stable con‐
ditions:
• Absolute
differen‐
ces be‐
tween:
• Oil temper‐
ature value
and chip 2
tempera‐
ture value
P0715 Input Tur‐ • ASIC HW • ASIC • Open cir‐ • No failure de‐ • 200.0 • 2 DCY
bine/ monitoring CG124 in‐ cuit or tected in sen‐ ms
Speed dicates short cir‐ sor voltage
Sensor cuit to supply
"A" Cir‐ ground
cuit
P0716 Input/Tur‐ • Rationality • More than • Input • No failure de‐ • 300.0 • 2 DCY
bine check one of the speed, tected in sen‐ ms
Shaft following output sor voltage
Speed speed sig‐ speed supply
Sensor nals are
"A" Cir‐ defective: • Or wheel • Engine
cuit speed speed > 430
Range/ RPM
Perform‐ • No failure de‐
ance tected in en‐
gine speed
CAN mes‐
sage
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Input • Input • No failure de‐
speed sen‐ speed and tected in sen‐
sor and engine sor voltage
engine speed supply
speed sig‐ CAN mes‐
nal are sage
faulty
P0720 Output • ASIC HW • ASIC • Open cir‐ • No failure de‐ • Con‐ • 2 DCY
Shaft monitoring CG124 in‐ cuit or tected in sen‐ tinu‐
Speed dicates short to sor voltage ous
Sensor ground supply
Circuit
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P0721 Output • Rationality • Difference • > 350 RPM • No failure de‐ • Con‐ • 2 DCY
Shaft check to output tected in sen‐ tinu‐
Speed speed cal‐ • > 250 RPM sor voltage ous
Sensor culated supply,
Circuit from wheel wheel speed
Range/ speed signal, input
Perform‐ speed signal
ance • And differ‐
ence to • And electri‐
output cal output
speed cal‐ speed sen‐
culated sor monitor‐
from input ing
speed
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Affected • The actual
clutches: A ratio has to
or D stay in de‐
fined
bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Affected • And output
clutches: B speed >= 50
or E RPM
• Affected
clutches: C
or D
• Affected
clutches: B
or C
• Affected
clutches: A
or B or E
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Affected • Or last in‐ • And output
clutches: A put speed speed < 50
or B or D value - ac‐ RPM
tual input
• Affected speed
clutches: A • (Time be‐
or B or C tween
measure‐
ments: 30
ms)
• Affected
clutches: A
or B or E
• Affected
clutches: B
or C or E
• Affected
clutches: B
or D or E
• Affected
clutches: B
or C or D
• Affected
clutches: C
or D or E
• Affected
clutches: A
or C or D
• Affected
clutches: A
or D or E
• Affected
clutches: A
or B or D
P0741 Torque • Rationality • Absolute • > CC Con‐ • Torque con‐ • 20,000.0• 2 DCY
Convert‐ check difference vClutch verter clutch ms
er Clutch of actual MAX‐ closed or
Circuit slip and OFFXD closed loop • Continu‐
Perform‐ target slip RPM control ous
ance/
Stuck Off • Engine tor‐
que < 1,000
Nm
• TCC-pres‐
sure > 3 bar
P0746 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"A" Per‐ • Feedback • Power sup‐
for‐ (PWM) ply voltage
>= 6.5 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
mance/ • Short to • And < 19.2 V
Stuck Off ground or
open pin
P0747 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"A" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P0748 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"A" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• SPI com‐ • Check • > Sync-pe‐ • Power sup‐
munication byte of riod + 20 ply activated
monitoring message µs
wrong • Power sup‐
• < Sync-pe‐ ply voltage
• Read back riod - 20 µs >= 6.5 V
of sent
message • And < 19.2 V
failed
• PWM
feedback
period
P0749 Pressure • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"A" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
P0750 Shift Sol‐ • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
enoid "A" pass to register) ply activated tinu‐
ground ous
• Power sup‐
• Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• SPI com‐ • Check • > Sync-pe‐ • Power sup‐
munication byte of riod + 20 ply activated
monitoring message µs
wrong • Power sup‐
• < Sync-pe‐ ply voltage
• Read back riod - 20 µs >= 6.5 V
of sent
message • And < 19.2 V
failed
• PWM
feedback
period
P0751 Shift Sol‐ • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
enoid "A" ground register) ply activated tinu‐
Perform‐ • 100% ous
ance/ • Short to • Feedback • Power sup‐
Stuck Off ground or (PWM) ply voltage
open pin >= 6.5 V
• And < 19.2 V
P0752 Shift Sol‐ • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
enoid "A" tery register) ply activated tinu‐
Stuck On • 0% ous
• Feedback • Power sup‐
(PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P0754 Shift Sol‐ • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
enoid "A" register) ply activated tinu‐
Intermit‐ ous
tent • Power sup‐
ply voltage
>= 6.5 V
• And < 19.2 V
P0776 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"B" Per‐ • Short to • Feedback • Power sup‐
for‐ ground or (PWM) ply voltage
mance/ open pin >= 6.5 V
Stuck Off • And < 19.2 V
P0777 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"B" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P0778 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"B" Elec‐ • Power sup‐
trical ply voltage
>= 6.5 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Dynamic • And < 19.2 V
bypass to
ground
P0779 Pressure • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"B" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P077 Output • ASIC HW • ASIC • Short cir‐ • No failure de‐ • Con‐ • 2 DCY
C Shaft monitoring CG124 in‐ cuit to bat‐ tected in sen‐ tinu‐
Speed dicates tery volt‐ sor voltage ous
Sensor age supply
Circuit
Low
P0780 Shift Er‐ • Shifting • General • 3 • 2 DCY
ror from gear: 1 descrip‐ times
tion: 30.0
• Shifting ms
from gear: 2 • While shift‐
ing from • Con‐
gear X to tinu‐
• Shifting gear Y the ous
from gear: 3 ratio also
has to stay
• Shifting in defined
from gear: 4 bounds.
While shift‐
ing it is not
possible to
relate the
reason of
the mal‐
function to
specific
clutches. If
one of the
following
malfunc‐
tion criteri‐
on is de‐
tected, a
fault code
is stored,
that corre‐
sponds to
the starting
gear of the
shifting.
P0796 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid ous
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
"C" Per‐ • Short to • Feedback • 100% • Power sup‐
for‐ ground or (PWM) ply voltage
mance/ open pin >= 6.5 V
Stuck Off
• And < 19.2 V
P0797 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"C" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P0798 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"C" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• SPI com‐ • Check • > Sync-pe‐ • Power sup‐
munication byte of riod + 20 ply activated
monitoring message µs
wrong • Power sup‐
• < Sync-pe‐ ply voltage
• Read back riod - 20 µs >= 6.5 V
of sent
message • And < 19.2 V
failed
• PWM
feedback
period
P0799 Pressure • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"C" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
P07B Input/Tur‐ • ASIC HW • ASIC • Open cir‐ • No failure de‐ • 100.0 • 2 DCY
F bine monitoring CG124 in‐ cuit or tected in sen‐ ms
Shaft dicates short cir‐ sor voltage
Speed cuit to supply
Sensor ground
"A" Cir‐
cuit Low
P2637 Torque • Signal • Failure val‐ • No failure de‐ • Con‐ • 2 DCY
Manage‐ check ue re‐ tected on tinu‐
ment ceived CAN Bus ous
Feed‐
back Sig‐ • And battery
nal "A" voltage > 9 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2700 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: A descrip‐ times
Friction tion: 30.0
Element ms
"A" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2701 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: B descrip‐ times
Friction tion: 30.0
Element ms
"B" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2702 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: C descrip‐ times
Friction tion: 30.0
Element ms
"C" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2703 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: D descrip‐ times
Friction tion: 30.0
Element ms
"D" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2704 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: E descrip‐ times
Friction tion: 30.0
Element ms
"E" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
P2714 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"D" Per‐ • Feedback
for‐ (PWM)
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
mance/ • Short to • Power sup‐
Stuck Off ground or ply voltage
open pin >= 6.5 V
• And < 19.2 V
P2715 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"D" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P2716 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"D" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• SPI com‐ • Check • > Sync-pe‐ • Power sup‐
munication byte of riod + 20 ply activated
monitoring message µs
wrong • Power sup‐
• < Sync-pe‐ ply voltage
• Read back riod - 20 µs >= 6.5 V
of sent
message • And < 19.2 V
failed
• PWM
feedback
period
P2717 Pressure • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"D" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
P2723 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"E" Per‐ • Short to • Feedback • Power sup‐
for‐ ground or (PWM) ply voltage
mance/ open pin >= 6.5 V
Stuck Off • And < 19.2 V
P2724 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"E" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P2725 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"E" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Current too • SW (calcu‐ • >= 50.0 +
high lation) 170.0 mA
feedback
PWM • >= Calcu‐
lated lim‐
• No shift‐ its, de‐
ing: pending on
incoming
• Measured current
current gradient
• During mA
shifting:
• Measured
current
P2726 Pressure • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"E" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
P2732 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"F" Per‐ • Short to • Feedback • Power sup‐
for‐ ground or (PWM) ply voltage
mance/ open pin >= 6.5 V
Stuck Off • And < 19.2 V
P2733 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"F" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P2734 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"F" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Current too • SW (calcu‐ • <= 850.0 – • Power sup‐
low lation) 120.0 mA ply activated
feedback
PWM • <= Calcu‐ • Power sup‐
lated lim‐ ply voltage
• No shift‐ its, de‐ >= 8.4 V
ing: pending on
incoming • And < 19.2 V
• Measured current
current gradient
• During
shifting:
• Measured
current
P2735 Pressure • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"F" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2753 Trans‐ • Open pin • PWM out‐ • <= 2.4 V • Power sup‐ • Con‐ • 2 DCY
mission put duty ply activated tinu‐
Fluid cycle • > 2.4 V ous
Cooler range 5 – • • Power sup‐
<4V ply voltage
Control 95 %
Circuit/ • <= 4 V >= 6.5 V
Open • Measured
voltage in • <= [] 23.5;
duty phase 18.69; V
23.5; 18.69;
• And in no 18.69 V
duty phase
• PWM out‐
put duty
cycle
range 0 – 5
%
• Measured
voltage in
no duty
phase
P2754 Trans‐ • Short to • Feedback • <= 2.4 V • Power sup‐ • Con‐ • 2 DCY
mission ground (PWM) ply activated tinu‐
Fluid ous
Cooler • Measured • PWM output
Control voltage in duty cycle
Circuit no duty range 0 – 95
Low phase %
• Power sup‐
ply voltage
>= 6.5 V
• <= [] 23.5;
18.69; V
23.5; 18.69;
18.69 V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2755 Trans‐ • Short to bat‐ • Measured • >= 3.5 V • Power sup‐ • Con‐ • 2 DCY
mission tery voltage ply activated tinu‐
Fluid from feed‐ ous
Cooler back • PWM output
Control (PWM) in duty cycle
Circuit duty phase range 5 – 100
High %
• Power sup‐
ply voltage
>= 6.5 V and
<= 23.5;
18.69; V
23.5; 18.69;
18.69 V16V
P2808 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground or register) ply activated tinu‐
Solenoid open pin ous
"G" Per‐ • PWM output
for‐ duty cycle
mance/ range 100 %
Stuck Off • Power sup‐
ply voltage
>= 6.5 V
• <= [] 23.5;
18.69; V
23.5; 18.69;
18.69 V
P2812 Pressure • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"G" Con‐ • Power sup‐
trol Cir‐ ply voltage
cuit/Open >= 6.5 V
• And < 19.2 V
P2813 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"G" Con‐ • Power sup‐
trol Cir‐ • Dynamic ply voltage
cuit bypass to >= 6.5 V
Range/ ground • And < 19.2 V
Perform‐
ance
• Current too • SW (calcu‐ • <= 850.0 – • Power sup‐
low lation) 120.0 mA ply activated
feedback
PWM • <= Calcu‐ • Power sup‐
lated lim‐ ply voltage
• No shift‐ its, de‐ >= 8.4 V
ing: pending on
incoming • And < 19.2 V
• Measured current
current gradient
• During
shifting:
• Measured
current
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Current too • SW (calcu‐ • >= 50.0 +
high lation) 170.0 mA
feedback
PWM • >= Calcu‐
lated lim‐
• No shift‐ its, de‐
ing: pending on
incoming
• Measured current
current gradient
• During mA
shifting:
• Measured
current
P2814 Pressure • Short to • Feedback • <= 2.4 V • Power sup‐ • Con‐ • 2 DCY
Control ground (PWM) ply activated tinu‐
Solenoid ous
"G" Con‐ • Measured • PWM output
trol Cir‐ voltage in duty cycle
cuit Low no duty range 0 – 95
phase %
• Power sup‐
ply voltage
>= 6.5 V
• <= [] 23.5;
18.69; V
23.5; 18.69;
18.69 V
P2815 Pressure • Short to bat‐ • Measured • >= 3.5 V • Power sup‐ • Con‐ • 2 DCY
Control tery voltage ply activated tinu‐
Solenoid from feed‐ ous
"G" Con‐ back • PWM output
trol Cir‐ (PWM) in duty cycle
cuit High duty phase range 5 – 100
%
• Power sup‐
ply voltage
>= 6.5 V and
<= 23.5;
18.69; V
23.5; 18.69;
18.69 V16V
AL-551-8QE 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
U000 High • Rationality • CAN Bus • Off • Con‐ • 2 DCY
1 Speed check state tinu‐
CAN ous
Commu‐
nication
Bus
U000 High • Time out • Time out • Battery volt‐ • Con‐ • 2 DCY
2 Speed for all re‐ age > 9.0 V tinu‐
CAN ceived ous
Commu‐ messages • And
nication on A-CAN • Battery volt‐
Bus Per‐ age < 17.0 V
formance
U010 Lost • Time out • Message • Expired • No fault de‐ • Con‐ • 2 DCY
0 Commu‐ specific tected on tinu‐
nication time CAN Bus ous • Imme‐
With diate
ECM/ • And
PCM "A" • Battery volt‐
age > 9.0 V
• And
• Battery volt‐
age < 17.0 V
U040 Invalid • Time out • Message • Expired • No fault de‐ • Con‐ • 2 DCY
1 Data Re‐ specific tected on tinu‐
ceived time CAN Bus ous • Imme‐
From diate
ECM/ • And
PCM "A" • Battery volt‐
age > 9.0 V
• And
• Battery volt‐
age < 17.0 V
• Monitoring
of the DN
reset line
failed
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Plausibility • Hardware • Peripheral
check doesn't re‐ clock active
port any on
error al‐
though the • And
peripheral • Delay time
clock is passed
switched
off
• Or
• Peripheral
is switched
on
• And
• There are
hardware
error re‐
ports for at
least two
cycles
• Failure in
program
flow con‐
trol
• Software • SW - or
check configura‐
tion fault in
WDOG
SW-Modul
• Plausibility • An ASIC
check status fail‐
ure has
been de‐
tected
• A moni‐
tored mod‐
ule status
failure has
been de‐
tected
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• RAM ECC • ECC test • Failed
monitoring,
RAM ECC
interrupt
monitoring,
ROM ECC
monitoring
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P0667 Control • With only • Number of • >1 • < • 2 DCY
Module one defec‐ defective 300.0
Internal tive sensor, tempera‐ s
Tempera‐ the trans‐ ture sen‐
ture Sen‐ mission sor signals
sor "A" uses one of
Range/ the remain‐
Perform‐ ing sensor
ance signals as
substitute
value and is
therefore
fully func‐
tional (no
MIL illumi‐
nation and
fault code
storage).
The moni‐
toring of the
3 sensors is
described
below. If at
least one of
the descri‐
bed moni‐
toring strat‐
egies for
each sen‐
sor detects
a malfunc‐
tion, the re‐
spective
sensor is
considered
defective. If
more than
one temper‐
ature sen‐
sor is defect
a fault is
stored and
the MIL is il‐
luminated.
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Circuit con‐ • Voltage at • > 4.7 V
tinuity sensor
plus pin (U • < 0.508 V
pin hi) • > 0.423 V
• Voltage at • < 0.005 V
sensor
plus pin (U • > 4.512 V
pin hi)
• < 0.135 V
• Voltage at
sensor mi‐ • > 15.5
nus pin (U • < 10
pin lo)
• Voltage at
sensor mi‐
nus pin (U
pin lo)
• Difference
voltage at
sensor
pins (U
sensor)
• Difference
voltage at
sensor
pins (U
sensor)
• Resistor
ratio (U
supply - U
sensor) / U
pin lo
• Resistor
ratio (U
supply - U
sensor) / U
pin lo
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Oil temper‐ • > 30° C • Engine
ature value speed or in‐
and chip 1 put speed >
tempera‐ 400 RPM
ture value
and oil • And >= 300.0
tempera‐ s
ture value
and chip 2
tempera‐
ture value
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Rationality • Absolute • > 10° C • No failure de‐ • 300.0
check differen‐ tected in oth‐ s
ces be‐ • > 15° C er chip tem‐
tween • > 30° C perature
Chip 1 and sensor moni‐
Chip 2 tors
tempera‐
ture value • No failure de‐
tected in in‐
• And put speed
signal and
• In thermo‐ engine
dynamic speed signal
stable con‐
ditions: • Engine
speed or in‐
• Absolute put speed >
differen‐ 400 RPM
ces be‐
tween: • And >= 300.0
s
• Oil temper‐
ature value
and chip 1
tempera‐
ture value
• In thermo‐
dynamic
stable con‐
ditions:
• Absolute
differen‐
ces be‐
tween:
• Oil temper‐
ature value
and chip 1
tempera‐
ture value
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Rationality • Absolute • > 10° C • No failure de‐ • 300.0
check differen‐ tected in oth‐ s
ces be‐ • > 15° C er chip tem‐
tween • > 30° C perature
Chip 1 and sensor moni‐
Chip 2 tors
tempera‐
ture value • No failure de‐
tected in in‐
• And put speed
signal and
• In thermo‐ engine
dynamic speed signal
stable con‐
ditions: • Engine
speed or in‐
• Absolute put speed >
differen‐ 400 RPM
ces be‐
tween: • And >= 300.0
s
• Oil temper‐
ature value
and chip 2
tempera‐
ture value
• In thermo‐
dynamic
stable con‐
ditions:
• Absolute
differen‐
ces be‐
tween:
• Oil temper‐
ature value
and chip 2
tempera‐
ture value
P0715 Input Tur‐ • ASIC HW • ASIC • Open cir‐ • No failure de‐ • 200.0 • 2 DCY
bine/ monitoring CG124 in‐ cuit or tected in sen‐ ms
Speed dicates short cir‐ sor voltage
Sensor cuit to supply
"A" Cir‐ ground
cuit
P0716 Input/Tur‐ • Rationality • More than • Input • No failure de‐ • 300.0 • 2 DCY
bine check one of the speed, tected in sen‐ ms
Shaft following output sor voltage
Speed speed sig‐ speed supply
Sensor nals is de‐
"A" Cir‐ fective: • Or wheel • Engine
cuit speed speed > 430
Range/ RPM
Perform‐ • No failure de‐
ance tected in en‐
gine speed
CAN mes‐
sage
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Input • Input • No failure de‐
speed sen‐ speed and tected in sen‐
sor and engine sor voltage
engine speed supply
speed sig‐ CAN mes‐
nal are sage
faulty
P0720 Output • ASIC HW • ASIC • Open cir‐ • No failure de‐ • Con‐ • 2 DCY
Shaft monitoring CG124 in‐ cuit or tected in sen‐ tinu‐
Speed dicates short to sor voltage ous
Sensor ground supply
Circuit
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P0721 Output • Rationality • Difference • > 350 RPM • No failure de‐ • Con‐ • 2 DCY
Shaft check to output tected in sen‐ tinu‐
Speed speed cal‐ • > 250 RPM sor voltage ous
Sensor culated supply,
Circuit from wheel wheel speed
Range/ speed signal, input
Perform‐ speed signal
ance • And differ‐
ence to • And electri‐
output cal output
speed cal‐ speed sen‐
culated sor monitor‐
from input ing
speed
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Affected • The actual
clutches: A ratio has to
or D stay in de‐
fined
bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Affected • And output
clutches: B speed >= 50
or E RPM
• Affected
clutches: C
or D
• Affected
clutches: B
or C
• Affected
clutches: A
or B or E
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Affected • Or last in‐ • And output
clutches: A put speed speed < 50
or B or D value - ac‐ RPM
tual input
• Affected speed
clutches: A • (Time be‐
or B or C tween
measure‐
ments:
30.0 ms)
• Affected
clutches: A
or B or E
• Affected
clutches: B
or C or E
• Affected
clutches: B
or D or E
• Affected
clutches: B
or C or D
• Affected
clutches: C
or D or E
• Affected
clutches: A
or C or D
• Affected
clutches: A
or D or E
• Affected
clutches: A
or B or D
P0741 Torque • Rationality • Absolute • > CC Con‐ • Torque con‐ • 20,000.0• 2 DCY
Convert‐ check difference vClutch verter clutch ms
er Clutch of actual MAX‐ closed or
Circuit slip and OFFXD closed loop • Continu‐
Perform‐ target slip RPM control ous
ance/
Stuck Off • Engine tor‐
que < 1,000
Nm
• TCC-pres‐
sure > 3 bar
P0746 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"A" Per‐ • Feedback • Power sup‐
for‐ (PWM) ply voltage
>= 6.5 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
mance/ • Short to • And < 19.2 V
Stuck Off ground or
open pin
P0747 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"A" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P0748 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"A" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• SPI com‐ • Check • > Sync-pe‐ • Power sup‐
munication byte of riod + 20 ply activated
monitoring message µs
wrong • Power sup‐
• < Sync-pe‐ ply voltage
• Read back riod - 20 µs >= 6.5 V
of sent
message • And < 19.2 V
failed
• PWM
feedback
period
P0749 Pressure • Open pin • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"A" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
P0750 Shift Sol‐ • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
enoid "A" pass to register) ply activated tinu‐
ground ous
• Power sup‐
• Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• SPI com‐ • Check • > Sync-pe‐ • Power sup‐
munication byte of riod + 20 ply activated
monitoring message µs
wrong • Power sup‐
• < Sync-pe‐ ply voltage
• Read back riod - 20 µs >= 6.5 V
of sent
message • And < 19.2 V
failed
• PWM
feedback
period
P0751 Shift Sol‐ • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
enoid "A" ground register) ply activated tinu‐
Perform‐ • 100% ous
ance/ • Short to • Feedback • Power sup‐
Stuck Off ground or (PWM) ply voltage
open pin >= 6.5 V
• And < 19.2 V
P0752 Shift Sol‐ • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
enoid "A" tery register) ply activated tinu‐
Stuck On • 0% ous
• Feedback • Power sup‐
(PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P0754 Shift Sol‐ • Open pin • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
enoid "A" register) ply activated tinu‐
Intermit‐ ous
tent • Power sup‐
ply voltage
>= 6.5 V
• And < 19.2 V
P0776 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"B" Per‐ • Short to • Feedback • Power sup‐
for‐ ground or (PWM) ply voltage
mance/ open pin >= 6.5 V
Stuck Off • And < 19.2 V
P0777 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"B" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P0778 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"B" Elec‐ • Power sup‐
trical ply voltage
>= 6.5 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Dynamic • And < 19.2 V
bypass to
ground
P0779 Pressure • Open pin • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"B" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P077 Output • ASIC HW • ASIC • Short cir‐ • No failure de‐ • Con‐ • 2 DCY
C Shaft monitoring CG124 in‐ cuit to bat‐ tected in sen‐ tinu‐
Speed dicates tery volt‐ sor voltage ous
Sensor age supply
Circuit
Low
P0780 Shift Er‐ • Shifting • General • 3 • 2 DCY
ror from gear: 1 descrip‐ times
tion: 30.0
• Shifting ms
from gear: 2 • While shift‐
ing from • Con‐
gear X to tinu‐
• Shifting gear Y the ous
from gear: 3 ratio also
has to stay
• Shifting in defined
from gear: 4 bounds.
While shift‐
ing it is not
possible to
relate the
reason of
the mal‐
function to
specific
clutches. If
one of the
following
malfunc‐
tion criteri‐
on is de‐
tected, a
fault code
is stored,
that corre‐
sponds to
the starting
gear of the
shifting.
P0796 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid ous
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
"C" Per‐ • Short to • Feedback • 100% • Power sup‐
for‐ ground or (PWM) ply voltage
mance/ open pin >= 6.5 V
Stuck Off
• And < 19.2 V
P0797 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"C" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P0798 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"C" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• SPI com‐ • Check • > Sync-pe‐ • Power sup‐
munication byte of riod + 20 ply activated
monitoring message µs
wrong • Power sup‐
• < Sync-pe‐ ply voltage
• Read back riod - 20 µs >= 6.5 V
of sent
message • And < 19.2 V
failed
• PWM
feedback
period
P0799 Pressure • Open pin • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"C" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
P07B Input/Tur‐ • ASIC HW • ASIC • Short cir‐ • No failure de‐ • 100.0 • 2 DCY
F bine monitoring CG124 in‐ cuit to bat‐ tected in sen‐ ms
Shaft dicates tery volt‐ sor voltage
Speed age supply
Sensor
"A" Cir‐
cuit Low
P2637 Torque • Signal • Failure val‐ • No failure de‐ • Con‐ • 2 DCY
Manage‐ check ue re‐ tected on tinu‐
ment ceived CAN Bus ous
Feed‐
back Sig‐ • And battery
nal "A" voltage > 9.0
V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2700 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: A descrip‐ times
Friction tion: 30.0
Element ms
"A" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2701 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: B descrip‐ times
Friction tion: 30.0
Element ms
"B" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2702 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: C descrip‐ times
Friction tion: 30.0
Element ms
"C" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2703 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: D descrip‐ times
Friction tion: 30.0
Element ms
"D" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2704 Trans‐ • Affected • General • 3 • 2 DCY
mission clutches: E descrip‐ times
Friction tion: 30.0
Element ms
"E" Apply • The actual
Time ratio has to • Con‐
Range/ stay in de‐ tinu‐
Perform‐ fined ous
ance bounds. If
one of the
following
malfunc‐
tion criteria
is detec‐
ted, the
fault code
for the 3
corre‐
sponding
clutches in
that gear is
set and a
gear shift
to a substi‐
tute gear is
initiated.
Depending
on the be‐
havior in
the substi‐
tute gear,
an addi‐
tional fault
code for
only one or
two clutch‐
es may be
set to bet‐
ter distin‐
guish the
root cause
of the
problem.
Shifting to
further
substitute
gears is
possible
with the
goal to
identify a
single de‐
fective
clutch.
• Example:
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Malfunc‐
tion criteria
detection
in 4th gear
--> DTC for
clutches
"B or D or
E" set and
shifting to
5th gear
(substitute
gear). IF
malfunc‐
tion criteria
in 5th gear
still active
--> DTC for
clutches
"B or D"
set and
shifting to
6th gear
(substitute
gear),
ELSE -->
DTC for
clutch "E"
set IF mal‐
function
criteria in
6th gear
still active
--> DTC for
clutch "D"
set and
shifting to
3rd gear
(substitute
gear),
ELSE -->
DTC for
clutch "B"
set IF mal‐
function
criteria in
3rd gear
still active
--> DTC for
"undefined
clutches"
is set be‐
cause root
cause can‐
not be re‐
lated to a
single
clutch.
P2714 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"D" Per‐ • Feedback
for‐ (PWM)
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
mance/ • Short to • Power sup‐
Stuck Off ground or ply voltage
open pin >= 6.5 V
• And < 19.2 V
P2715 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"D" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P2716 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"D" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• SPI com‐ • Check • > Sync-pe‐ • Power sup‐
munication byte of riod + 20 ply activated
monitoring message µs
wrong • Power sup‐
• < Sync-pe‐ ply voltage
• Read back riod - 20 µs >= 6.5 V
of sent
message • And < 19.2 V
failed
• PWM
feedback
period
P2717 Pressure • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"D" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
P2723 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"E" Per‐ • Short to • Feedback • Power sup‐
for‐ ground or (PWM) ply voltage
mance/ open pin >= 6.5 V
Stuck Off • And < 19.2 V
P2724 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"E" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P2725 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"E" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Current too • SW (calcu‐ • >= 50.0 +
high lation) 170.0 mA
feedback
PWM • >= Calcu‐
lated lim‐
• No shift‐ its, de‐
ing: pending on
incoming
• Measured current
current gradient
• During mA
shifting:
• Measured
current
P2726 Pressure • Open circuit • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"E" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
P2732 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground register) ply activated tinu‐
Solenoid • 100% ous
"F" Per‐ • Short to • Feedback • Power sup‐
for‐ ground or (PWM) ply voltage
mance/ open pin >= 6.5 V
Stuck Off • And < 19.2 V
P2733 Pressure • Short to bat‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control tery register) ply activated tinu‐
Solenoid • 0% ous
"F" Stuck • Feedback • Power sup‐
On (PWM) ply voltage
>= 6.5 V
• And < 19.2 V
P2734 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"F" Elec‐ • Power sup‐
trical • Dynamic ply voltage
bypass to >= 6.5 V
ground • And < 19.2 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Current too • SW (calcu‐ • <= 850.0 – • Power sup‐
low lation) 120.0 mA ply activated
feedback
PWM • <= Calcu‐ • Power sup‐
lated lim‐ ply voltage
• No shift‐ its, de‐ >= 8.4 V
ing: pending on
incoming • And < 19.2 V
• Measured current
current gradient
• During
shifting:
• Measured
current
P2735 Pressure • Open pin • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"F" Inter‐ • Power sup‐
mittent ply voltage
>= 6.5 V
• And < 19.2 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2753 Trans‐ • Open pin • PWM out‐ • <= 2.4 V • Power sup‐ • Con‐ • 2 DCY
mission put duty ply activated tinu‐
Fluid cycle • > 2.4 V ous
Cooler range 5 – • • Power sup‐
< 4.0 V ply voltage
Control 95%
Circuit/ • <= 4.0 V >= 6.5 V
Open • Measured
voltage in • <= [] 23.5;
duty phase 18.69; V
23.5; 18.69;
• And in no 18.69 V
duty phase
• PWM out‐
put duty
cycle
range 0 –
5%
• Measured
voltage in
no duty
phase
P2754 Trans‐ • Short to • Feedback • <= 2.4 V • Power sup‐ • Con‐ • 2 DCY
mission ground (PWM) ply activated tinu‐
Fluid ous
Cooler • Measured • PWM output
Control voltage in duty cycle
Circuit no duty range 0 – 95
Low phase %
• Power sup‐
ply voltage
>= 6.5 V
• <= [] 23.5;
18.69; V
23.5; 18.69;
18.69 V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
P2755 Trans‐ • Short to bat‐ • Measured • >= 3.5 V • Power sup‐ • Con‐ • 2 DCY
mission tery voltage ply activated tinu‐
Fluid from feed‐ ous
Cooler back • PWM output
Control (PWM) in duty cycle
Circuit duty phase range 5 – 100
High %
• Power sup‐
ply voltage
>= 6.5 V and
<= 23.5;
18.69; V
23.5; 18.69;
18.69 V16V
P2808 Pressure • Short to • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control ground or register) ply activated tinu‐
Solenoid open pin ous
"G" Per‐ • PWM output
for‐ duty cycle
mance/ range 100 %
Stuck Off • Power sup‐
ply voltage
>= 6.5 V
• <= [] 23.5;
18.69; V
23.5; 18.69;
18.69 V
P2812 Pressure • Open pin • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control register) ply activated tinu‐
Solenoid ous
"G" Con‐ • Power sup‐
trol Cir‐ ply voltage
cuit/Open >= 6.5 V
• And < 19.2 V
P2813 Pressure • Static by‐ • ASIC (SPI • Faulty • Power sup‐ • Con‐ • 2 DCY
Control pass to register) ply activated tinu‐
Solenoid ground ous
"G" Con‐ • Power sup‐
trol Cir‐ • Dynamic ply voltage
cuit bypass to >= 6.5 V
Range/ ground • And < 19.2 V
Perform‐
ance
• Current too • SW (calcu‐ • <= 850.0 – • Power sup‐
low lation) 120.0 mA ply activated
feedback
PWM • <= Calcu‐ • Power sup‐
lated lim‐ ply voltage
• No shift‐ its, de‐ >= 8.4 V
ing: pending on
incoming • And < 19.2 V
• Measured current
current gradient
• During
shifting:
• Measured
current
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
• Current too • SW (calcu‐ • >= 50.0 +
high lation) 170.0 mA
feedback
PWM • >= Calcu‐
lated lim‐
• No shift‐ its, de‐
ing: pending on
incoming
• Measured current
current gradient
• During mA
shifting:
• Measured
current
P2814 Pressure • Short to • Feedback • <= 2.4 V • Power sup‐ • Con‐ • 2 DCY
Control ground (PWM) ply activated tinu‐
Solenoid ous
"G" Con‐ • Measured • PWM output
trol Cir‐ voltage in duty cycle
cuit Low no duty range 0 – 95
phase %
• Power sup‐
ply voltage
>= 6.5 V
• <= [] 23.5;
18.69; V
23.5; 18.69;
18.69 V
P2815 Pressure • Short to bat‐ • Measured • >= 3.5 V • Power sup‐ • Con‐ • 2 DCY
Control tery voltage ply activated tinu‐
Solenoid from feed‐ ous
"G" Con‐ back • PWM output
trol Cir‐ (PWM) in duty cycle
cuit High duty phase range 5 – 100
%
• Power sup‐
ply voltage
>= 6.5 V and
<= 23.5;
18.69; V
23.5; 18.69;
18.69 V16V
AL-551-8Q 0BW
DTC Fault Monitor Strat‐ Malfunction Threshold Secondary Pa‐ Monitor‐ Frequen‐
Code De‐ egy Descrip‐ Criteria Value rameters with ing Time cy of
scription tion Enable Condi‐ Length checks,
tions MIL Illum
U000 High • Rationality • CAN Bus • Off • Con‐ • 2 DCY
1 Speed check state tinu‐
CAN ous
Commu‐
nication
Bus
U000 High • Time out • Time out • Battery volt‐ • Con‐ • 2 DCY
2 Speed for all re‐ age > 9.0 V tinu‐
CAN ceived ous
Commu‐ messages • And
nication on A-CAN • Battery volt‐
Bus Per‐ age < 17.0 V
formance
U010 Lost • Time out • Message • Expired • No fault de‐ • Con‐ • 2 DCY
0 Commu‐ specific tected on tinu‐
nication time CAN Bus ous • Imme‐
With diate
ECM/ • And
PCM "A" • Battery volt‐
age > 9.0 V
• And
• Battery volt‐
age < 17.0 V
• CHECK: Accelerator Pedal Module - GX2- har‐ ♦ GO TO: Step 6 ⇒ page 897 .
ness connector terminal 5 to the Engine Con‐
trol Module - J623- harness connector T91 / 51
for resistance.
• CHECK: Accelerator Pedal Module - GX2- har‐
ness connector terminal 1 to the Engine Con‐
trol Module - J623- harness connector T91 / 16
for resistance.
• SPECIFIED VALUE: 0.5 Ω (± 0.3 Ω)
– Were Values obtained?
6 • Final Procedure – YES:
♦ CHECK: Engine Control Module - J623- har‐
• Perform a road test to verify repair. ness connector for any damaged, pushed-out
– Does the original DTC return? pins.
♦ REPAIR: As necessary.
♦ If all electrical connections are OK:
♦ REPLACE: Engine Control Module - J623- .
Refer to appropriate repair manual.
♦ Clear the DTC’s. Refer to
⇒ “3.3.4 Diagnostic Mode 04 - Erase DTC
Memory”, page 29 .
♦ Repair is complete. Generate Readiness
Code. Refer to
⇒ “3.2 Readiness Code”, page 21 .
♦ Return vehicle to Customer.
– NO:
♦ Perform the diagnostic procedure for any
DTCs.
♦ If no DTC’s return the repair is complete.
♦ Return vehicle to Customer.
♦ Multimeter.
♦ Wiring Diagram.
♦ Scan Tool.
Test requirements
• Fuses OK.
• Battery voltage OK.
• Switch OFF all electrical and electronic accessories.
• Vehicles with automatic transmission, ensure the selector lev‐
er position is in “P”.
• Vehicles with manual transmission, ensure the shifter lever
position is in “N” with the parking brake applied.
• Observe all safety precautions:
⇒ “1.1 Safety Precautions”, page 2 .
• View clean working conditions:
⇒ “1.2 Clean Working Conditions”, page 3 .
• For Hybrid vehicles, refer to:
⇒ “1.3 High Voltage System General Warnings”, page 4 .
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 900 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
♦ Scan Tool.
Test requirements
• Fuses OK.
• Battery voltage OK.
• Switch OFF all electrical and electronic accessories.
• Vehicles with automatic transmission, ensure the selector lev‐
er position is in “P”.
• Vehicles with manual transmission, ensure the shifter lever
position is in “N” with the parking brake applied.
• Observe all safety precautions:
⇒ “1.1 Safety Precautions”, page 2 .
• View clean working conditions:
⇒ “1.2 Clean Working Conditions”, page 3 .
• For Hybrid vehicles, refer to:
⇒ “1.3 High Voltage System General Warnings”, page 4 .
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 902 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
Test requirements
• Fuses OK.
• Battery voltage OK.
• Switch OFF all electrical and electronic accessories.
• Vehicles with automatic transmission, ensure the selector lev‐
er position is in “P”.
• Vehicles with manual transmission, ensure the shifter lever
position is in “N” with the parking brake applied.
• Observe all safety precautions:
⇒ “1.1 Safety Precautions”, page 2 .
• View clean working conditions:
⇒ “1.2 Clean Working Conditions”, page 3 .
• For Hybrid vehicles, refer to:
⇒ “1.3 High Voltage System General Warnings”, page 4 .
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 904 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 909 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 927 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
• IGNITION: OFF.
• SPECIFIED VALUE: Battery voltage.
– Were Values obtained?
4 • REMOVE: Jumper wire, between the Engine – YES:
Component Power Supply Relay - J757- sock‐ ♦ REPLACE: Engine Component Power Supply
et terminals 3 and 5. Relay - J757- . Refer to appropriate repair man‐
ual.
• REMOVE: Engine Control Module - J623- .
Refer to appropriate repair manual. ♦ GO TO: Step 5 ⇒ page 928 .
• CHECK: Engine Component Power Supply – NO:
Relay - J757- socket terminal 2 to the Engine ♦ PERFORM: Visual Inspection of wiring and
Control Module - J623- harness connector component.
T91 / 73 for resistance.
♦ CHECK: Wiring for open, high resistance,
• SPECIFIED VALUE: 0.5 Ω (± 0.3 Ω). short or harness connector for damage, corro‐
sion, loose or broken terminals.
– Was Value obtained?
♦ REPAIR: Faulty wiring or connector.
♦ GO TO: Step 5 ⇒ page 928 .
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 929 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 933 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
Note
• CHECK: Transfer Fuel Pump - G6- harness ♦ GO TO: Step 7 ⇒ page 942 .
connector terminal 3 to the Fuel Pump Control
Module - J538- harness connector terminal 1
for resistance.
• SPECIFIED VALUE: 0.5 Ω ( ± 0.3 Ω ).
– Were Values obtained?
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 947 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 959 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 961 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
Test requirements
• Fuses OK.
• Battery voltage OK.
• Switch OFF all electrical and electronic accessories.
• Vehicles with automatic transmission, ensure the selector lev‐
er position is in “P”.
• Vehicles with manual transmission, ensure the shifter lever
position is in “N” with the parking brake applied.
• Observe all safety precautions:
⇒ “1.1 Safety Precautions”, page 2 .
• View clean working conditions:
⇒ “1.2 Clean Working Conditions”, page 3 .
• For Hybrid vehicles, refer to:
⇒ “1.3 High Voltage System General Warnings”, page 4 .
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 966 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint verified? ♦ GATHER more information from customer
about the complaint.
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to Oxygen Sensor ♦ GO TO: Step 2 ⇒ page 971 .
Preliminary Tests in
⇒ “3.1 Preliminary Check”, page 20 . – NO:
♦ GATHER more information from customer
– Was Complaint verified? about the complaint.
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to Oxygen Sensor ♦ GO TO: Step 2 ⇒ page 977 .
Preliminary Tests in
⇒ “3.1 Preliminary Check”, page 20 . – NO:
♦ GATHER more information from customer
– Was Complaint verified? about the complaint.
Function test
Step Procedure Result / Action to Take
1 Activate Monitors: ♦ Check the exhaust system for leaks.
• Perform the function test in the appropriate Di‐
agnostic Mode 06. Refer to ♦ If necessary, repair the leak(s) in the exhaust
⇒ “3.3 Diagnostic Modes 01 – 0A”, page 23 . system.
• End diagnosis and switch the ignition off. ♦ GO TO: Step 2 ⇒ page 987 .
• Perform a road test to verify repair. ♦ Replace the catalytic converter with front ex‐
haust pipe. Refer to appropriate repair manual.
• If the DTC does not return:
♦ GO TO: Step 3 ⇒ page 987 .
3 • Final procedure: • After the repair work, the following work steps
must be performed in the following sequence:
• Perform a road test to verify repair.
• Check the DTC memory. Refer to
⇒ “3.3.3 Diagnostic Mode 03 - Read DTC
Memory”, page 27 .
• If necessary, erase the DTC memory. Refer to
⇒ “3.3.4 Diagnostic Mode 04 - Erase DTC
Memory”, page 29 .
• If the DTC memory was erased, generate read‐
iness code. Refer to
⇒ “3.2 Readiness Code”, page 21 .
• Return vehicle to Customer.
♦ Multimeter.
♦ Wiring Diagram.
♦ Scan Tool.
Test requirements
• Fuses OK.
• Battery voltage OK.
• Switch OFF all electrical and electronic accessories.
• Vehicles with automatic transmission, ensure the selector lev‐
er position is in “P”.
• Vehicles with manual transmission, ensure the shifter lever
position is in “N” with the parking brake applied.
• Observe all safety precautions:
⇒ “1.1 Safety Precautions”, page 2 .
• View clean working conditions:
⇒ “1.2 Clean Working Conditions”, page 3 .
• For Hybrid vehicles, refer to:
⇒ “1.3 High Voltage System General Warnings”, page 4 .
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 988 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint Verified? ♦ GATHER more information from customer
about the complaint.
• CHECK: Throttle Valve Control Module - GX3- ♦ GO TO: Step 6 ⇒ page 990 .
harness connector terminal 4 to the Engine
Control Module - J623- harness connector
T105 / 34 for resistance.
• CHECK: Throttle Valve Control Module - GX3-
harness connector terminal 5 to the Engine
Control Module - J623- harness connector
T105 / 91 for resistance.
• SPECIFIED VALUE: 0.5 Ω (± 0.3 Ω).
– Were Values obtained?
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to ♦ GO TO: Step 2 ⇒ page 991 .
⇒ “3.1 Preliminary Check”, page 20 .
– NO:
– Was Complaint Verified? ♦ GATHER more information from customer
about the complaint.
Test Procedure
Step Procedure Result / Action to Take
1 • PERFORM: Preliminary Check to verify the – YES:
customers complaint. Refer to . ♦ GO TO: Step 2 ⇒ page 993 .
– Was Complaint verified? – NO:
♦ GATHER more information from customer
about the complaint.
DAB 11-29-16 FB