Welding Parameters
Welding Parameters
Sarajevo 2023
https://weldguru.com/mig-welder-settings/
Recommended Welding Parameters:
Carbon & Low Alloy Steel Electrodes - Flux Cored - Flat and Horizontal - CO2 - DCEP
Flat and Horizontal Flux Cored Electrodes - Carbon & Low Alloy Steel
77
Recommended Welding Parameters:
Carbon & Low Alloy Steel Electrodes - Flux Cored - All Position- CO2* - DCEP
* For Ar-25% CO2 shielding gas reduce the voltage by 1 to 1.5 volts
All Position Flux Cored Electrodes - Carbon & Low Alloy Steel
78
Recommended Welding Parameters: Carbon and Low Alloy Steel
Metal Cored - Argon/Carbon Dioxide - DCEP
79
Recommended Welding Parameters: Carbon and Low Alloy Steel Flux Cored - Self-Shielded
73 DCEP Volts ESO Amps WFS (ipm) Volts Amps WFS (ipm) Volts
74 DCEP Volts ESO Amps WFS (ipm) Volts Amps WFS (ipm) Volts
80
Recommended Welding Parameters:
Flux Cored, Austenitic (3XX) & Duplex (2XXX) Stainless Steel - Flat & Horizontal
WFS (ipm) Amps Volts ESO
.035” Flat & Horizontal Flux Cored (CO2)* 200 75 22 1/2 - 5/8”
300 105 24 1/2 - 5/8”
400 125 26 1/2 - 5/8”
550 155 27 1/2 - 5/8”
650 165 29 1/2 - 5/8”
.045” Flat & Horizontal Flux Cored (CO2)* 200 120 25 5/8 - 3/4”
335 170 27 5/8 - 3/4”
440 200 29 5/8 - 3/4”
780 290 35 5/8 - 3/4”
1/16” Flat & Horizontal Flux Cored (CO2)* 150 150 24 3/4 - 1”
235 210 28 3/4 - 1”
345 270 31 3/4 - 1”
500 350 34 3/4 - 1”
* When using Ar-25% CO2 for flux cored arc welding lower the voltage by 2 volts
81
Recommended Welding Parameters:
Flux Cored, Austenitic (3XX-AP) & Duplex (2XXX-AP) Stainless Steel - All Position
82
Recommended Welding Parameters:
Austenitic (3XX) & Duplex (2XXX) Stainless Steel - Metal Cored
83
Recommended Welding Parameters:
Austenitic (3XXT0-3) Stainless Steel Electrodes - Self-Shielded
* For Ar-25% CO2 shielding gas reduce the voltage by 1 to 1.5 volts
84
Recommended Welding Parameters:
Ferritic and Martensitic Stainless Steel (4XX Series) - Metal Cored - Argon/Oxygen - DCEP
85