0% found this document useful (0 votes)
108 views16 pages

Welding Parameters

The document provides recommended welding parameters for various materials and processes, including: 1) Parameters for flux cored welding of carbon and low alloy steels in flat, horizontal, and all positions. 2) Parameters for metal cored welding of carbon and low alloy steels using argon/carbon dioxide shielding gas. 3) Self-shielded flux cored parameters for carbon and low alloy steels. 4) Parameters for flux cored welding of austenitic and duplex stainless steels in flat and horizontal positions.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
0% found this document useful (0 votes)
108 views16 pages

Welding Parameters

The document provides recommended welding parameters for various materials and processes, including: 1) Parameters for flux cored welding of carbon and low alloy steels in flat, horizontal, and all positions. 2) Parameters for metal cored welding of carbon and low alloy steels using argon/carbon dioxide shielding gas. 3) Self-shielded flux cored parameters for carbon and low alloy steels. 4) Parameters for flux cored welding of austenitic and duplex stainless steels in flat and horizontal positions.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 16

Welding parameters

Prepared by: DSc PhD Dževad Hadžihafizović (DEng)

Sarajevo 2023
https://weldguru.com/mig-welder-settings/
Recommended Welding Parameters:
Carbon & Low Alloy Steel Electrodes - Flux Cored - Flat and Horizontal - CO2 - DCEP

Operating Range Optimum


Diameter Amps WFS (ipm) Volts Amps WFS (ipm) Volts ESO
1/8” 450-800 75-180 30-36 600 125 32 3/4 - 1 1/4”
7/64” 375-700 80-240 28-36 550 150 30 3/4 - 1 1/4”
3/32” 300-550 110-270 26-34 425 180 29 3/4 - 1 1/4”
5/64” 280-430 140-300 26-33 390 250 29 3/4 - 1 1/4”
1/16” 150-400 130-500 22/34 330 330 29 1/2 - 1”
.045” 130-330 160-670 21/32 250 450 28 1/2 - 1”

Flat and Horizontal Flux Cored Electrodes - Carbon & Low Alloy Steel

77
Recommended Welding Parameters:
Carbon & Low Alloy Steel Electrodes - Flux Cored - All Position- CO2* - DCEP

Operating Range Optimum


Diameter Position Amps Volts Amps WFS (ipm) Volts ESO
1/16” Flat 150-400 22-34 330 330 29 1/2 - 1”
Overhead 150-310 22-28 225 180 26 1/2 - 1”
Vertical Up 150-280 22-27 225 180 25 1/2 - 1”
.052” Flat 140-330 19-32 275 400 28 1/2 - 1”
Overhead 150-290 21-28 200 245 26 1/2 - 1”
Vertical Up 140-270 21-27 200 245 25 1/2 - 1”
.045” Flat 130-300 21-32 250 450 28 1/2 - 1”
Overhead 150-280 21-30 190 305 26 1/2 - 1”
Vertical Up 130-260 21-29 190 305 25 1/2 - 1”
.035” Flat 125-250 21-30 200 600 27 3/8 - 3/4”
Overhead 115-220 21-28 175 490 25 3/8 - 3/4”
Vertical Up 120-215 21-28 170 450 25 3/8 - 3/4”

* For Ar-25% CO2 shielding gas reduce the voltage by 1 to 1.5 volts

All Position Flux Cored Electrodes - Carbon & Low Alloy Steel

78
Recommended Welding Parameters: Carbon and Low Alloy Steel
Metal Cored - Argon/Carbon Dioxide - DCEP

Operating Range Optimum


Diameter Amps WFS (ipm) Volts Amps WFS (ipm) Volts ESO
1/8” 450-625 95-145 26-32 500 100 28-29 1 - 1 1/4”
3/32” 400-600 125-250 28-36 420 165 29-30 1 - 1 1/4”
5/64” 350-550 170-350 27-36 450 245 29-30 1 - 1 1/4”
1/16” 240-520 175-500 26-37 360 300 29-30 3/4 - 1 1/4”
.052” 220-460 220-620 25-35 300 350 29-30 1/2 - 1”
.045” 190-330 240-600 27-33 255 410 29-30 1/2 - 1”
.035” 180-320 350-750 29-36 200 550 29-30 1/2 - 3/4”

Carbon and Low Alloy Steel

79
Recommended Welding Parameters: Carbon and Low Alloy Steel Flux Cored - Self-Shielded

Operating Range Optimum Flat & Horizontal Optimum Vertical and OH


Diameter Amps
701, 700GS DCEN Volts ESO Amps WFS (ipm) Volts Amps WFS (ipm) Volts

.030” 40-180 14-18 3/8 - 1/2” 125 215 15 100 170 15


.035” 60-220 14-19 3/8 - 1/2” 170 225 16 125 160 17
.045” 80-240 15-20 3/8 - 3/4” 200 190 17 170 155 17
1/16” 130-300 15-20 1/2 - 3/4” 250 110 18 170 90 16
5/64” 180-350 16-22 3/4 - 1” 300 75 18 – – –
3/32” 220-400 16-22 3/4 - 1” 325 65 19 – – –

73 DCEP Volts ESO Amps WFS (ipm) Volts Amps WFS (ipm) Volts

5/64” 300-450 24-28 1 - 1 1/4” 400 245 26 – – –


3/32” 350-500 25-29 1 - 1 1/4” 450 200 27 – – –
.120” 400-550 26-30 1 - 1 1/4” 500 145 28 – – –

74 DCEP Volts ESO Amps WFS (ipm) Volts Amps WFS (ipm) Volts

1/16” 175-260 28-31 1 3/4” 200 205 30 – – –


5/64” 200-350 28-34 2 3/4” 250 185 30 – – –
3/32” 250-400 28-33 2 3/4” 350 190 30 – – –
.120” 400-550 29-33 2 3/4” 450 135 31 – – –

Select 78 Welding Parameters

Operating Range Optimum Flat & Horizontal Optimum Vertical and OH


Amps
Diameter DCEN Volts ESO Amps WFS (ipm) Volts Amps WFS (ipm) Volts

5/64” 180-350 18-23 1 1/4” 270 170 22 250 140 21


.072” 150-350 19-24 1” 290 200 22 250 160 21
1/16” 150-280 19-24 1” 240 275 22 210 200 22

80
Recommended Welding Parameters:
Flux Cored, Austenitic (3XX) & Duplex (2XXX) Stainless Steel - Flat & Horizontal
WFS (ipm) Amps Volts ESO

.035” Flat & Horizontal Flux Cored (CO2)* 200 75 22 1/2 - 5/8”
300 105 24 1/2 - 5/8”
400 125 26 1/2 - 5/8”
550 155 27 1/2 - 5/8”
650 165 29 1/2 - 5/8”
.045” Flat & Horizontal Flux Cored (CO2)* 200 120 25 5/8 - 3/4”
335 170 27 5/8 - 3/4”
440 200 29 5/8 - 3/4”
780 290 35 5/8 - 3/4”
1/16” Flat & Horizontal Flux Cored (CO2)* 150 150 24 3/4 - 1”
235 210 28 3/4 - 1”
345 270 31 3/4 - 1”
500 350 34 3/4 - 1”
* When using Ar-25% CO2 for flux cored arc welding lower the voltage by 2 volts

81
Recommended Welding Parameters:
Flux Cored, Austenitic (3XX-AP) & Duplex (2XXX-AP) Stainless Steel - All Position

WFS (ipm) Amps Volts ESO

.035” All Position Flux Cored (CO2)* 300 110 25 3/4 - 1”


500 150 26 3/4 - 1”
600 165 27 3/4 - 1”
700 175 28 3/4 - 1”
.045” All Position Flux Cored (CO2)*2) 250 130 24 5/8 - 3/4”
300 160 26 5/8 - 3/4”
425 200 28 5/8 - 3/4”
780 270 34 5/8 - 3/4”
1/16” All Position Flux Cored (CO2)*2) 150 170 25 3/4 - 1”
195 215 27 3/4 - 1”
240 250 28 3/4 - 1”
320 305 29 3/4 - 1”
* When using Ar-25% CO2 for flux cored arc welding lower the voltage by 2 volts

82
Recommended Welding Parameters:
Austenitic (3XX) & Duplex (2XXX) Stainless Steel - Metal Cored

WFS (ipm) Amps Volts ESO

.045” Metal Cored (Ar-2%O2) 250 180 21 1/2 - 5/8”


400 240 23 1/2 - 5/8”
500 280 25 1/2 - 5/8”
650 300 27.5 1/2 - 5/8”
1/16” Metal Cored (Ar-2%O2)) 150 190 24 3/4 - 1”
250 280 25 3/4 - 1”
350 385 26 3/4 - 1”
450 490 32 3/4 - 1”

83
Recommended Welding Parameters:
Austenitic (3XXT0-3) Stainless Steel Electrodes - Self-Shielded

Diameter WFS (ipm) Amperage Voltage ESO

.045” 180 100 24-26 5/8-3/4”


240 125 24-27 5/8-3/4”
300 145 25-28 5/8-3/4”
400 170 27-30 5/8-3/4”
500 190 29-31 5/8-3/4”
1/16” 150 126 27-30 3/4-1”
200 155 29-32 3/4-1”
250 190 28-31 3/4-1”
300 215 30-33 3/4-1”
350 240 31-33 3/4-1”
3/32” 135 250 25-27 1 1/4-1 1/2”
180 300 27-29 1 1/4-1 1/2”
225 350 28-30 1 1/4-1 1/2”
300 400 29-31 1 1/4-1 1/2”
340 450 29-31 1 1/4-1 1/2”

Recommended Welding Parameters: Martensitic Stainless Steel Electrodes


(410, 410NiMo) - Flux Cored - Flat and Horizontal - CO2 - DCEP

Operating Range Optimum


Diameter Amps WFS (ipm) Volts Amps WFS (ipm) Volts ESO
1/16” 150-400 130-500 22/34 330 330 29 1/2 - 1”
.045” 130-330 160-670 21/32 250 450 28 1/2 - 1”

Recommended Welding Parameters: Martensitic Stainless Steel Electrodes


(410-AP, 410NiMo-AP) - Flux Cored - All Position- CO2* - DCEP

Operating Range Optimum


Diameter Position Amps Volts Amps WFS (ipm) Volts ESO
1/16” Flat 150-400 22-34 330 330 29 1/2 - 1”
Overhead 150-310 22-28 225 180 26 1/2 - 1”
Vertical Up 150-280 22-27 225 180 25 1/2 - 1”
.045” Flat 130-300 21-32 250 450 28 1/2 - 1”
Overhead 150-280 21-30 190 305 26 1/2 - 1”
Vertical Up 130-260 21-29 190 305 25 1/2 - 1”

* For Ar-25% CO2 shielding gas reduce the voltage by 1 to 1.5 volts

84
Recommended Welding Parameters:
Ferritic and Martensitic Stainless Steel (4XX Series) - Metal Cored - Argon/Oxygen - DCEP

Operating Range Optimum


Diameter Amps WFS (ipm) Volts Amps WFS (ipm) Volts ESO
1/16” 230-520 160-500 22-31 360 300 26 3/4 - 1 1/4”
.052” 220-460 220-620 23-30 300 350 26 1/2 - 1”
.045” 180-330 240-600 22-28 255 410 26 1/2 - 1”
.035” 180-320 350-750 23-29 200 550 25 1/2 - 3/4”

Recommended Welding Parameters:


Nickel Alloys, All Position - Flux Cored - CO2 or 75% Argon/25%CO2

Operating Range Optimum


Diameter Amps WFS (ipm) Volts ESO Amps WFS (ipm) Volts
.045” (Flat) 125-200 250-450 25-30 ˜ 1/2” 180 400 27.5
.045” (Vertical Up & Overhead) 120-165 250-350 25-27 ˜ 5/8” 140 300 26

85