Astm B88
Astm B88
TABLE 1 Dimensions, Mass, and Tolerances in Diameter and Wall Thickness for Metric Copper Water Tube Sizes
(All tolerances are plus and minus except as otherwise indicated.)
Average Outside
Wall Thickness and Tolerances, mm Theoretical Mass, kg/m
Nominal or Outside DiameterA Tolerance, mm
Standard Diameter, Type A Type B Type C
Size, mm mm Annealed Drawn Wall Toler- Wall Toler- Wall Toler- Type A Type B Type C
Thickness anceB Thickness anceB Thickness anceB
C
6 6.0 0.05 0.03 0.80 0.08 0.70 0.07 0.60 0.117 0.104 0.091
C
8 8.0 0.05 0.03 0.90 0.09 0.80 0.08 0.60 0.179 0.162 0.125
C
10 10.0 0.05 0.03 0.90 0.09 0.80 0.08 0.60 0.230 0.207 0.158
12 12.0 0.06 0.03 1.2 0.1 0.90 0.09 0.60 0.06 0.364 0.280 0.192
15 15.0 0.06 0.03 1.2 0.1 1.0 0.1 0.70 0.07 0.465 0.393 0.281
18 18.0 0.06 0.03 1.2 0.1 1.0 0.1 0.70 0.07 0.566 0.477 0.340
22 22.0 0.06 0.03 1.6 0.15 1.1 0.1 0.80 0.08 0.917 0.646 0.476
28 28.0 0.07 0.04 1.6 0.15 1.2 0.1 0.90 0.09 1.19 0.903 0.685
35 35.0 0.10 0.04 1.6 0.15 1.4 0.15 1.1 0.1 1.50 1.32 1.05
42 42.0 0.10 0.05 1.8 0.2 1.5 0.15 1.2 0.1 2.03 1.71 1.37
54 54.0 0.10 0.05 2.1 0.2 1.7 0.15 1.5 0.15 3.06 2.50 2.21
67 67.0 0.12 0.05 2.4 0.25 2.0 0.2 1.6 0.15 4.35 3.65 2.94
79 79.0 0.12 0.05 2.8 0.3 2.3 0.25 1.8 0.2 5.99 4.95 3.90
105 105.0 0.12 0.05 3.4 0.35 2.8 0.3 2.4 0.25 9.70 8.04 6.92
130 130.0 0.12 0.05 4.0 0.4 3.1 0.3 2.7 0.25 14.2 11.0 9.65
156 156.0 0.12 0.05 4.8 0.5 3.5 0.35 3.1 0.3 20.3 15.0 13.3
206 206.0 0.15 + 0.05 6.8 0.7 5.0 0.5 4.3 0.45 38.0 28.2 24.4
−0.10
257 257.0 0.20 + 0.05 8.5 0.85 6.3 0.65 5.4 0.55 59.3 44.4 38.2
−0.15
308 308.0 0.20 + 0.05 10.3 1.0 7.1 0.7 6.4 0.65 86.1 60.0 54.2
−0.15
A
The average outside diameter of a tube is the average of the maximum and minimum outside diameter, as determined at any one cross section of the tube.
B
Maximum deviation at any one point.
C
Indicates that the material is not generally available or that no tolerance has been established.
SUPPLEMENTARY REQUIREMENTS
The following supplementary requirements shall apply only when specified by the purchaser in the
inquiry, contract, or order, for agencies of the U.S. Government.
S1. Referenced Documents requirements unless disapproved by the purchaser at the time
S1.1 The following documents of the issue in effect on date the order is placed. The purchaser shall have the right to
of material purchase form a part of this specification to the perform any of the inspections and tests set forth in this
extent referenced herein: specification when such inspections and tests are deemed
S1.1.1 Federal Standards:5 necessary to ensure that the material conforms to the prescribed
Fed. Std. No. 102 Preservation, Packaging and Packing requirements.
Levels S3. Identification Marking
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
S3.1 All material shall be properly marked for identification
Fed. Std. No. 146A Tolerances for Copper and Copper Base
in accordance with Fed. Std. No. 185 except that the ASTM
Alloy Mill Products
specification number and the alloy number shall be used.
Fed. Std. No. 185 Identification Marking of Copper and
Copper-Base Alloy Mill Products S4. Preparation for Delivery
S1.1.2 Military Standards:5
S4.1 Preservation, Packaging, Packing:
MIL-STD-105 Sampling Procedures and Tables for Inspec-
S4.1.1 Military Agencies—The material shall be separated
tion by Attributes
by size, composition, grade, or class and shall be preserved and
MIL-STD-129 Marking for Shipment and Storage
packaged, Level A or C, packed, Level A, B, or C, as specified
S2. Quality Assurance in the contract or purchase order, in accordance with the
requirements of Practice B900.
S2.1 Responsibility for Inspection: S4.1.2 Civil Agencies—The requirements of Fed. Std. No.
S2.1.1 Unless otherwise specified in the contract or pur- 102 shall be referenced for definitions of the various levels of
chase order, the manufacturer is responsible for the perfor- packaging protection.
mance of all inspection and test requirements specified. Except S4.2 Marking:
as otherwise specified in the contract or purchase order, the S4.2.1 Military Agencies—In addition to any special mark-
manufacturer has the option to use his own or any other ing required by the contract or purchase order, marking for
suitable facilities for the performance of the inspection and test shipment shall be in accordance with MIL-STD-129.
S4.2.2 Civil Agencies—In addition to any special marking
5
Available from DLA Document Services, Building 4/D, 700 Robbins Avenue, required by the contract or purchase order, marking for
Philadelphia, PA 19111-5094, http://quicksearch.dla.mil/. shipment shall be in accordance with Fed. Std. No. 123.
SUMMARY OF CHANGES
Committee B05 has identified the location of selected changes to this standard since the last issue
(B88M-05(2011)) that may impact its use:
(1) Removed definitions which have been defined in B846 (4) Deleted requirement in 5.3 Materials and Manufacture to
Standard Terminology for Copper and Copper Alloys. allow coils to be annealed prior to annealing.
(2) Made minor editorial corrections throughout the document. (5) In the Supplementary Requirements Section, removed ref-
(3) Made modifications to 10.1 Eddy-Current Test and to erence to withdrawn standard MIL-C-3993 and replaced with
14.5.2 Number of Tests and Retests to bring into line with reference to Practice B900.
Specification B88.
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222
Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http://www.copyright.com/