0% found this document useful (0 votes)
33 views4 pages

Test - Pile Report - R2

This document provides the design details for an initial load test pile for a road development project in Madhya Pradesh, India. It includes specifications for the pile such as a length of 20 meters and diameter of 1.2 meters. It also calculates the pile's lateral and vertical capacities. The depth of fixity is determined to be 10.1 meters for a fixed head pile and 8.8 meters for a free head pile. Reinforcement steel required is calculated to be 18 bars of 20mm diameter spaced at 183mm for vertical capacity and 24 bars of 20mm diameter spaced at 137mm for horizontal capacity.

Uploaded by

Fahad Iqbal
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
0% found this document useful (0 votes)
33 views4 pages

Test - Pile Report - R2

This document provides the design details for an initial load test pile for a road development project in Madhya Pradesh, India. It includes specifications for the pile such as a length of 20 meters and diameter of 1.2 meters. It also calculates the pile's lateral and vertical capacities. The depth of fixity is determined to be 10.1 meters for a fixed head pile and 8.8 meters for a free head pile. Reinforcement steel required is calculated to be 18 bars of 20mm diameter spaced at 183mm for vertical capacity and 24 bars of 20mm diameter spaced at 137mm for horizontal capacity.

Uploaded by

Fahad Iqbal
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 4

MADHYA PRADESH ROAD DEVELOPMENT CORPORATION

M/S A.S Construction Company

DESIGN OF INITIAL LOAD TEST PILE

Designed
by

DUCTILE DESIGN CONSULTANCY


PRIVATE LIMITED
CLIENT:

MADHYA PRADESH ROAD DEVELOPMENT COORPORATION

PROJECT TITLE:
REHABILITATION AND UPGRADATION OF PUBLIC PRIVATE PARTNERSHIP IN
MADHYA PRDESH ROAD SECTOR PROJECT (PPPMPRSP) FOR CIVIL CONTRACT
PKG NO. 17B (TAMIA - JUNARDEO ROAD)

DESIGNED BY:

DUCTILE DESIGN CONSULTANCY PVT LTD.

AUTHORITY ENGINEER

M/S AARVEE ASSOCIATES ARCHITECT


ENGINEERS & CONSULTANT

PREPARED BY:
REPORT NO: DDC/318/01
KANHAIYA

APPROVED BY:
DATE: 02/01/2024
VIKASH
Pile Length = 20.00 m
Pile Diameter = 1.20 m
Lateral Capacity
Fixed head pile = 20.0 t
Free head pile = 10.0 t

Vertical Capacity
Total vertical capacity = 247.00 t

Depth of fixity of pile


The Depth of Fixity for Pile has been determined by Cl 6.5.2 & appendix - C of IS : 2911 part-I sec-II
Grade of Concrete = 35 Mpa
Young's Modulus (E) 5000 √ fck = 29580398.92 kN/m2
Moment Of Inertia (I) πd4/64 = 0.102 m4
Cross-section area (A) πd2/4 = 1.1304 m2

Stiffness (R) = 4.6 m (Loose Sand)

Modulus of subgrade reaction


(nh)
= 1450.0 kN/m3

Free standing length L1 = 0 m NON-Scour Case


L1/R = 0 m
Ratio of fixity length and
Lf/R or Lf/T = 2.2
stiffness (Fixed)
Ratio of fixity length and
Lf/R or Lf/T = 1.9 Refer to IS 2911(Part-I/sec-2):2010 Fig. 4 Appendix-C
stiffness (free)
Length of fixity (Fixed) Lf = 10.1 m As per GT report
Length of fixity (Free) Lf = 8.8 m
L1+Lf = 10.1 m
L1+Lf = 8.8 m

Reduction Factor (Free) m = 0.4 Refer to IS 2911(Part-I/sec-2):2010 Fig. 5 Appendix-C

Reduction Factor (Fixed) m = 0.8

For Initial Load test

Vertical Load (Pu) = 617.50 t Refer to IS 2911(Part-IV):2013

Lateral Load (H) = 25 t Refer to IS 2911(Part-IV):2013

Moment
For Fixed Head Pile (Mғ) H*(L1+Lf)/2 = 101.35 t-m
For Free head Pile (Mғ) H*(L1+Lf) = 87.53 t-m

Steel Calculation
Vertical Pile Capacity
Check
Compressive strength of
Fck = 35 N/mm²
Concrete
Dia Of Bar D' = 20 mm
Clear Cover = 75 mm
Effective cover d' = 85 mm
Diameter of pile D = 1200 mm

d'/D = 0.07 Refer to SP 16:1980 Chart No 60

Pu/(fck*D²) = 0.1225
Moment as per 75mm
construction tolerence (Min. Mu = 46.31 tm
Eccentricity)
Mu/(fck*D³) = 0.01

% of steel pt/fck = 0.01 % Refer to SP 16:1980 Chart No 60


pt = 0.4 % for horizontal test take pu/fck*D2=0

Total steel Ast = 4523.89 mm²

No of Bar n = 14.4 ≈ 15
Provided bar = 18 no. OK
Spacing of bar = 183.3 mm
Horizontal Pile Capacity
Check
Compressive strength of
Fck = 35 N/mm²
Concrete
Dia Of Bar D' = 20 mm
Clear Cover = 75 mm
Effective cover d' = 85 mm
Diameter of pile D = 1200 mm

d'/D = 0.071 Refer to SP 16:1980 Chart No 60

Pu/(fck*D²) = 0.01 t
Moment as per 75mm
construction tolerence
Mu = 87.53 tm

Mu/(fck*D³) = 0.01

% of steel pt/fck = 0.016 Refer to SP 16:1980 Chart No 60


pt = 0.56 % for horizontal test take pu/fck*D2=0

Total steel Ast = 6333.45 mm²

No of Bar n = 20.16 ≈ 21
Provided bar = 24 no. OK
Spacing of bar = 137.4 mm

20mm@24Number

Adsec Input Adsec Output


Vertical Capacity Check Moment Capacity Stress in Concrete Stress in Steel
Normal Force 6057.7 kN
Moment Due to Minimum 2839.5 kN-m 7.76 49.32
454.3 kN-m
Tolernace Eccentricity

Adsec Input Adsec Output


Horizontal Capacity Check Moment Capacity Stress in Concrete Stress in Steel
Normal Force
1386.9 kN
(Weight of
Moment DuePile)
to Minimum
Tolernace Eccentricity and 1851.4 kN-m 11.16 101.6
Moment Due to Depth of 962.7 kN-m
Fixity