8.pmi Procedure
8.pmi Procedure
Project
Supplier Internal
Supplier Reference Number: MTI-PROJ-100-1031-018 02
Revision No.:
Supplier (Prepared By): Thomas John
Current Revision
30-Jun-2022 Purchaser Revision No: 02
Issue Date:
Sub-Sequential
Project Code P.O. No. VDRC Code Sequential No
No
Note : Sub-Sequential No Only Applicable To Minute Of Meeting, Technical Query, Progress Report And Drawings
TABLE OF CONTENTS:
4.0 CALIBRATION
Calibration shall be performed on a daily basis on a standard sample
provided with the equipment by the manufacturer & there should be
fully certified calibration blocks specific to the material being tested
available for verification.
Verification shall be done prior to start the work to check equipment
accuracy and When Examination personnel is changed during
examination and When an element of the examination system is
changed etc., and whenever required by client.
Document no: GPTI-MARSOL-PMI-001
Rev No: 01
POSITIVE MATERIAL INSPECTION Rev Date: 28/June/2022
PROCEDURE Page No: Page 5 of 10
In addition to the above, PMI equipment will be calibrated annually by an
external agency.
8.5 Materials that have been verified by PMI shall subsequently be marked
or wire tagged in order to identify them as being acceptable. Rejected
items should be marked ‘PMI REJECT’.
8.6 Materials shall contain the amount of alloying elements specified in
ASME Section II Part A (ASME SEC IIA) and ASME Section II Part B
Document no: GPTI-MARSOL-PMI-001
Rev No: 01
POSITIVE MATERIAL INSPECTION Rev Date: 28/June/2022
PROCEDURE Page No: Page 8 of 10
(ASME SEC II B) or equivalent ASTM specifications) for low alloy, alloy
and CRA ferrous and nonferrous materials.
9.0 MARKING:
9.1 If any major alloying elements are below the range specified by the
applicable material standard or a portable analyzer indicates an
incorrect match or “no match”, the component shall be rejected or sent
to laboratory. The laboratory analysis will determine acceptance or
rejection of the material. If any of the major alloying elements are
greater than the range specified by the applicable material standard,
the alloy content must be reported to the CONTRACTOR for
acceptance or rejection.
9.2 The MANUFACTRER or PIPE FABRICATOR shall identify, mark and
remove all unacceptable materials.
9.3 After inspection all rejected components shall be suitably marked and
segregated.
9.4 Marking shall be done with water-suitable material that contains no
harmful that would attack or harmfully affect the material at ambient or
elevated temperature. The marking material shall be free of lead,
sulfur, cadmium, mercury, chlorine or other halogens.
10.0 REPORTING:
Reporting shall include all details/information as below and provided in the
sample report format.
• name of project/Contractor/Client
• Date of examination
• Location
• Contract no / Job no
• Item/Component name / identification number
• Heat number
• Specified material
• Operator’s name
• Standard/Procedure no
• Equipment model / serial number / calibration date /
percentage errors.
• Drawing number/ Chemical Composition analyzed
Record of the test performed can be printed directly thru the PCs and copy
of the same may be attached with the front report sheet.
Note: PMI shall not be considered as a substitute for required mill test reports listing
chemical composition.
Document no: GPTI-MARSOL-PMI-001
Rev No: 01
POSITIVE MATERIAL INSPECTION Rev Date: 28/June/2022
PROCEDURE Page No: Page 9 of 10
11.0 SAFETY: