CRMX Slim Quick Start Guide
CRMX Slim Quick Start Guide
INTRODUCTION
Thank you for buying a LumenRadio CRMX Slim product. This
guide is intended to give you a quick start to experience the
benefits of LumenRadio’s CRMX system.
The CRMX products you just purchased are designed to give you
the highest reliability on the market and are fully compatible with
other CRMX products in professional lighting (CRMX Nova, CRMX
Outdoor, CRMX Slim, CRMX OEM). Through this you are able
to expand your wireless system with units from our other product
lines as well as with those of our partners. For the latest updates
please visit the LumenRadio website www.lumenradio.com.
We hope that you will enjoy our products and that they will bring
benefits and positive experiences.
k
Lin
RF Easy one-button operation.
See page 3 for details.
DMX
M
RD
LI
DA
NOTICE
To optimize range and performance:
• Keep antennas upright
ed • Maintain TX to RX line of sight
assur
nce
• Elevate the units above any crowds
ste
exi • Elevation above ground increases range
Co
• Keep away from large metal objects
The information furnished in this start guide is for informational use only and is subject to change without notice. Please check www.lumenradio.com for latest version.
LumenRadio AB assumes no responsibility or liability for any errors or inaccuracies that may appear in this start guide. All information and graphics are property of
LumenRadio AB, Svangatan 2B SE-416 68 Gothenburg, Sweden.
CONNECTIONS OPERATION
All connections are made via the two cable glands. CRMX Slim units can link with any other CRMX units as well as legacy W-DMX™ (G2/G3/G4) transmitters (2.4 GHz only).
USING SUPERNOVA
The default DMX address for the DALI/DSI interface is channel 1. After a discovery in SuperNova the Slim receiver will appear as
two units, the actual Slim wireless module as well as the DALI/DSI interface. The start address of the DALI/DSI interface can be set in
SuperNova. SuperNova runs on any Windows, Mac OS X or GNU/Linux computer with a Java runtime environment of at least version
1.6. The latest version of SuperNova as well as detailed user guides can be accessed at www.lumenradio.com/supernova.
SPECIFICATIONS
CORRECT USE OF THE CABLE GLANDS
Power input: 100-240VAC / 50-60Hz FIRMWARE UPGRADE
When used correctly, the glands offer full environmental protection up to IP65.
Maximum consumption: 3W
1. Each gland has a 2. Insert the cable 3. Retract the cable All CRMX units are upgradeable. Please
Operation temperature range: -20°C to +50°C (-4°F to 122°F)
membrane inside it. through the gland, with 1cm, to ensure the IP contact your local distributor for more
an additional 1cm of Environmental: IP65 (protected from water jets) information.
Puncture this using an seal.
appropriate tool or the cable than your desired Frequency range: 2.402 to 2.480 GHz
cable itself. length. Output power levels: 300mW (25dBm) (Permitted only
in North America), 100mW (20dBm),
35mW (15dBm), 10mW (10dBm)
Order code CRMX Slim receiver: 800-5001/OS-RRX1
Order code CRMX Slim transmitter: 800-5101/OS-DTX1
MOUNTING TEMPLATE (1:1)
TOP
5mm
11mm
90mm
174mm 152mm 156mm
Ø4mm
Ø4mm
11mm 13mm
Ø7mm
FCC statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, • Reorient or relocate the receiving antenna.
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against • Increase the separation between the equipment and receiver.
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful • Connect the equipment into an outlet on a circuit different from that to which the
interference to radio communications. However, there is no guarantee that interference will not occur in receiver is connected.
a particular installation. If this equipment does cause harmful interference to radio or television recep- • Consult the dealer or an experienced radio/TV technician for help.
tion, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
EU Declaration of Conformity
FCC ID: XRSCRMXTIMO101
These products compliance with the Essential Requirements of the Radio
IC: 8879A-CRMXN101
Equipment Directive (RED) of the European Union (2014/53/EU).
This equipment meets the following conformance standards: SRRC CMIT ID: 2011DJ0708 US Patent 7,432,803
ETSI EN 301 489-1 V2.1.1; ETSI EN 301 489-3 V2.1.1; R 001 - A
ETSI EN 300 328 V2.2.1; EN 60950 00019
Release 5.0 May 2020
CRMX™, CRMX Nova™, CRMX Outdoor™, CRMX Slim™, CRMX OEM™, CRMX SuperNova™ are trademarks of LumenRadio AB. W-DMX™ is a trademark of Wireless Solution
Sweden AB. CRMX is patented by LumenRadio, CE, FCC, ICES, SRRC and ARIB STD-T66 approved.