Read First
Safety Information
Understand and follow operating instructions carefully.
Use the meter only as specified in this manual; otherwise, the
protection provided by the meter may be impaired.
WARNING
Identifies hazardous conditions and actions that could cause
BODILY HARM or DEATH
CAUTION
Identifies conditions and actions that could DAMAGE the meter
or equipment under test
WARNING
˙ When using test leads or probes, keep your fingers behind
the finger guards.
˙ Remove test lead from Meter before opening the battery
door or Meter case.
˙ Use the Meter only as specified in this manual or the protec-
tion by the Meter might be impaired.
˙Always use proper terminals, switch position, and range for
measurements.
˙Verify the Meter’s operation by measuring a known voltage.
If in doubt, have the Meter serviced.
˙ Do not apply more than the rated voltage, as marked on
Meter, between terminals or between any terminal and
earth ground.
˙ Use caution with voltages above 30 Vac rms, 42 Vac peak,
or 60 Vdc. These voltages pose a shock hazard.
˙ To avoid false readings that can lead to electric shock and
injury, replace battery as soon as low battery indicator.
˙ Disconnect circuit power and discharge all high-voltage
capacitors before testing resistance, continuity, diodes, or
capacitance.
˙ Do not use Meter around explosive gas or vapor.
˙ To reduce the risk of fire or electric shock do not expose this
product to rain or moisture.
1
CAUTION
˙ Disconnect the test leads from the test points before chang-
ing the position of the function rotary switch.
˙ Never connect a source of voltage with the function rotary
switch in Ω, &, position.
˙ Do not expose Meter to extremes in temperature or high
humidity.
˙ Never set the meter in Ω, &, function to measure the
voltage of a power supply circuit in equipment that could
result in damage the meter and the equipment under test.
Symbols as marked on the Meter and Instruction
manual
Battery
Earth
AC measurement
Conforms to EU directives
Application around and removal from hazardous live
E conductors is permitted
Unsafe Voltage
To alert you to the presence of a potentially hazardous voltage,
when the Tester detects a voltage ≧30 V or a voltage
overload (OL) in V . The symbol is displayed.
Maintenance
Do not attempt to repair this Meter. It contains no userservice-
able parts. Repair or servicing should only be performed by
qualified personnel.
Cleaning
Periodically wipe the case with a dry cloth and detergent.
Do not use abrasives or solvents.
2
Feature
˙ 10000 Count digital display
˙ Active Backlit,Large scale display
˙ VoltSense (None Contact Voltage)
˙ Analog Bar graph
˙ True RMS reading on AC and AC+DC mode
˙ Torch lightening when clamping
˙ Auto AC/DC 600 Amps capability and selection
˙ Auto AC/DC 1000 Volts capability and selection
˙ Auto Ohms/Continuity/Diode selection
˙ 100K Resistance capability
˙ Continuity Beeper
˙ Frequency Counter
˙ Power and Power factor measurement
˙ Total Harmonics distortion and Harmonics 1 to 25
˙ Capacitance capability
˙ Inrush Current
˙ DCA Auto-Zeroing Key
˙ Peak Hold
˙ MIN/MAX HOLD
˙ Smart Data Hold
˙ Phase rotation indication
˙ Low pass Filter
˙ Auto Power Off
˙ CAT.Ⅳ 600V / CAT.Ⅲ 1000V Safety Standard
3
The Meter Description
Power on
4
Auto Power Off
Navigator KEY
UP
DOWN
5
Making Basic Measurements
Preparation and Caution Before Measurement
: Observe the rules of Warnings and Cautions
The figures on the following pages show how to make
basic measurements.
When connecting the test leads to the DUT (Device Under Test)
connect the common test lead before connecting the live lead ;
when removing the test leads, remove the test live lead before
removing the common test lead.
Measuring Voltage
6
Warning
To avoid electrical shock, hazard or damage to meter, do not
attempt to measurement that might exceed 1000 V DC or AC
RMS. Do not apply more then 1000 V DC or AC RMS between
the comment input terminal and earth ground.
Note - If the measured voltage is greater than 30 V DC or AC
RMS, the display will show the " " symbol.
Measuring Current
CAT.Ⅳ.600V
CAT.Ⅲ.1000V
with respect to
I
earth for the jaw.
Tactile Barrier for
hand guard.
Do not hold
the meter across
the Tactile Barrier.
OK
I I
I
OK
OK
I+(-I)=0
Caution
Please do not measure current from clamp jaw when tempera-
ture probe is connected to meter.
7
AUTO SENSE mode :
Display measurement result at AC only with RMS value or
DC value, it depends on whichever is greater.
AC mode : AC only with RMS value.
DC mode : DC value.
AC+DC mode : AC+DC RMS value.
Note
- Select " AC", " DC" or " AC+DC" indicator then press the
navigator key to enter the AC/DC/AC+DC mode.
- Select " AC"," DC" or " AC+DC" indicator then press the
navigator key for more than 2sec to return to the AUTO
SENSE mode.
"ENTER"
>2SEC
8
>2SEC
"ENTER"
>2SEC
Watting Tigger
After Tigger
ENTER
9
DCA ZERO
Remove the jaw out of the conductor.
Press HOLD Key > 2 Sec to compensate the residual
magnetism.
HOLD> 2 Sec
HOLD
"Hz"
ENTER
10
MAX/MIN/AVG
Select the "MAX MIN" indicator then press the navigator key to
enter the MAX/MIN/AVG mode. To quit from the MAX/MIN/AVG
mode, press the navigator key for more than 2sec.
"MAXMIN"
"MAXMIN"
ENTER
MAXMIN >2sec
"MAXMIN"
"MAXMIN"
NOTE :
- Press HOLD key in MAX MIN mode to make the meter stop
updating the maximum and minimum value. When the HOLD
mode is nested in MAX MIN mode, the HOLD mode must be
released before the MAX MIN mode.
11
THD Measurement (AC mode only)
Select the "THD" indicator then press the navigator key to
enter the THD mode.THD-F=RMS of Harmonics ÷ RMS of
fundamental ×100%.(harmonics up to the 25th)
"THD"
"ENTER"
ENTER
" " >2SEC
" "
"RIGHTWARD"
"LEFTWARD"
"UPWARD" "UPWARD"
"DOWNWARD" "DOWNWARD"
"RIGHTWARD"
"LEFTWARD"
12
LPF(AC mode only)
Select the "LPF" indicator then press the navigator key to
eliminate high frequency noise.
"LPF"
ENTER
NOTE :
Peak Hold, Inrush, THD, HZ, individual Harmonic and LPF
mode are only available in AC mode.
NOTE :
- The “ + ” symbol on the jaw must face on the power source
side.
- In AutoSense mode, The meter will displays ACW/DCW
depends on if there has AC frequency been detected.
Active power sign :
No sign : Indicates the power flows from the power source to
the load.
"_" sign : Indicates the power flows from the load to the
power source.
13
Power factor sign :
No sign : The phase of the current signal is lagging behind
the voltage signal (inductive load).
"_" sign : The phase of the current signal is leading the
voltage signal (capacitive load).
Overrange display :
OL.U : Voltage overload
OL.A : Current overload
OL.UA : Both Voltage and current overload.
± OL kW : Active Power > 600 kW or < -600 kW.
600A
+L
600V
-N
"PF" "W"
ENTER
14
2.Three Phase Power Measurement
A. 3 phase 3 wire balanced / unbalanced
Step1. Set the rotary switch to the "W" position
Step2. Using the Navigator key to choose the "W" mode.
W=W1+W2
1
3 2
Wye or star
Red
Red
Black Black
15
b. 3 phase 4 wire balanced / unbalanced
Step1. Set the rotary switch to the"W" position
Step2. Using the Navigator key to choose the "W" mode.
W=W1+W2+W3 1
3 Black Red
Black Red
Red
Black
16
Phase Rotation
Line 1
Line 2
Line 3
NOTE :
- Connect the supposed three phase of power source as shown
above.
- The test is only available while the system frequency is stable.
Step 1. Set the rotary switch to the "W" position.
Step 2. Using the Navigator key to choose the " " mode
Step 3. Connect the Red test lead to the supposed phase
Line 1, and the Black test lead to the supposed phase
Line 3.
a. if volt > 1000V, it will display “OLU” and flash; if volt <30V,
it will display “LoU”
b. If the frequency > 65Hz or < 45Hz, it will display “outF”
and flash.
c. If it is normal, then it will display “L1” and flash for about
3 sec.
17
Step 4. If it displays “L2”, then BUZZER will be sound for twice.
Please switch the Red test lead to connect to the
supposed phase Line 2 immediately before the “ L2 ” is
disappeared.
Step 5. When “L2” is disappeared, it will display the testing
result.
OHM Measurment
18
CAUTION
To avoid possible damage to the Meter or to the equipment
under test, disconnect circuit power and discharge all high -
voltage capacitors before measuring resistance and diode.
Note :
- Select "Ω", "#" or "%" indicator then press the navigator key
to enter the Ω/#/ %mode.
- Select "Ω", "#" or "%" indicator then press the navigator key
for more than 2sec to return to the AUTO SENSE mode.
Note - Under diode mode, LCD displays "bad" when measuring
a diode conducted at forward and reverse bias.
Measuring Capacitance
Set the rotary switch to the " &" position.
Capcitance
19
CAUTION
To avoid possible damage to the meter or to the equipment
under test, disconnect circuit power and discharge all high-
voltage capacitors before measuring capacitance. Use the
DC voltage function to confirm that the capacitor discharged.
Note - The meter will display “diSC” while discharging the
capacitor.
Other Function :
AUTO/MANUAL RANGE
Select the “RANGE“ indicator then press the navigator key to
enter the manual range mode. To return to the auto range
mode, press the navigator key for more than 2sec.
"Range"
"ENTER"
"Range"
"Range"
>2SEC
20
HOLD Key
Press HOLD key to freeze display value.
Press
Hold key
VoltSense :
The red diamond shape of LED will Illuminate, If there has
electric field been detected form the jaw.
Caution
The light indicator turns on while the
clamp tips are close to a electric field.
If no indication, voltage could still be
present.
21
Buzzer
The Meter beeps once for every valid key-press, and beeps
twice for every invalid key-press.
Power-up options:
Press one of the following keys while tuning meter on from OFF
position.
Upward of Navigator key : Display of the software version.
Downward of Navigator key : Disable auto power off.
Leftward of Navigator key : Disable active backlight.
HOLD KEY : Display all LCD symbols approx 10sec.
Battery Replacement
ICaution
Remove test leads
from Meter before
opening the battery
cover or Meter case.
22
Specifications
General Specifications
Display count : 10000 or 4000
Measuring rate : 3 times / sec.
Overrange display : “OL” or “-OL” .
Auto Power Off : Approx 15 minutes.
Low battery indicator : is displayed. Replace the battery
when the indicator appears in the display.
Power requirement : 9V battery.
Battery life : ALKALINE 9V 50 hours (without Backlight).
Dimensions : 87.5mm(W) x 242mm(L) x 50.5mm(D)
Weight : approx. 435g (with battery)
Environmental Conditions
Indoor Use.
Calibration : One year calibration cycle.
Operating temperature : 0 °C ~ 10 °C
10 °C ~ 30 °C (≦80% RH)
30 °C ~ 40 °C (≦75% RH)
40 °C ~ 50 °C (≦45%RH)
Storage temperature : -10 to 50 °C for current,
-20 to 60 °C for other function,
0 to 80% RH (batteries not fitted).
Temperature coefficient :
0.2 x (Specified accuracy) / °C, < 18°C, > 28°C .
Over voltage category : IEC 61010-1 600V CAT.Ⅳ.
1000V CAT.Ⅲ.
CAT Application field
23
Electrical Specifications
Accuracy is ±(% reading + number of digits) at 23°C ± 5°C
< 80%RH.
(1) Voltage
24
(2) Current
25
(4) Frequency
26
(6) Inrush Current :
27
(9) Resistance & Continuity & Diode :
(10) Capacitance :
28
Limited Warranty
This Meter is warranted to the original purchaser against defects
in material and workmanship for 2 years from the date of
purchase. During this warranty period, manufacturer will, at its
option, replace or repair the defective unit, subject to verification of
the defect or malfunction.
This warranty does not cover fuses, disposable batteries, or
damage from abuse, neglect, accident, unauthorized repair,
alteration, contamination, or abnormal conditions of operation
or handling.
Any implied warranties arising out of the sale of this product,
including but not limited to implied warranties of merchantability
and fitness for a particular purpose, are limited to the above.
The manufacturer shall not be liable for loss of use of the
instrument or other incidental or consequential damages,
expenses, or economic loss, or for any claim or claims for such
damage, expense or economic loss. Some states or countries
laws vary, so the above limitations or exclusions may not apply
to you.
29
Seaward Electronic Ltd
15-18 Bracken Hill, South West Industrial Estate
Peterlee, County Durham, UK
SR8 2SW
Tel: +44 (0)191 586 3511
Fax: +44 (0) 191 586 0227
Email: enquiry@seawardsolar.com
www.seawardsolar.com