DB_HIKRA_SOL_EN_2024
DB_HIKRA_SOL_EN_2024
HIKRA® SOL
EN50618 (H1Z2Z2-K) IEC62930 (IEC 131)
TÜV 2 PfG 2750 (PV 1500-WR)
DATASHEET
Construction
Strand construction Tin-plated copper strand (electrolytic copper), fine wire acc. IEC 60228 Class 5
Insulation Electron-beam cross-linked Polyolefin; Shore hardness D 32
Outer Sheath Electron-beam cross-linked special compound XLPO; Shore hardness D 36
Colour Sheath: black, red; Insulation: clear – naturally colored
Marking HIKRA SOL 1500V H1Z2Z2-K PV1500-WR IEC 62930 IEC 131 1x6,0mm²; R 50408873 CE; Metermarkierung
Standards EN50618 (H1Z2Z2-K) TÜV R 50363076; IEC62930 131 TÜV R 50408873, 2 PfG 2750/09.20 TÜV R 50533129
Technical characteristics
Nominal voltage 1,5 kV DC and 1,0 kV AC
Maximum permitted operating voltage 1,8 kV DC (2,0 kV internal examination)
Voltage test on complete cable 6,5 kV AC / 15 kV DC (5 minutes water bath , 20±5 °C)
Current carrying capacity See document „Current rating – HIKRA® Solar Cable“ October 2020
Short-circuit-temperature 250 °C/5 s
Material properties
Tensile strength and ultimate-elongation after 720 h (360 cycles) ≥ 70 % of initial values; EN 50289-4-17 acc. Method A; EN
UV stability
ISO 4892-1 (2000) and EN ISO 4892-2 (2006)
Ozone resistance 72 h, relative humidity 55±5 %, Temperature 40±2 °C (EN 50396 Method B; Ozone concentration (200±50)x10-6 )
Insulation resistance Insulation resistance in water bath, each 2 h at +90 °C and 2 h at 20 °C (Limit values acc. EN 50618 Table 1)
DC direct voltage test Water bath, at +85 °C +-5 °C, 240 h, test voltage 1.8 kV DC
Advanced DC dc voltage test Water bath, at +85 °C +-5 °C, 240 h, test voltage 3.6 kV DC (Floating PV TÜV 2 Pfg 2750)
14 days water storage at +90+-5 °C; capacitance measurement after 1 day. After 14 days capacity measurement max. 10 %,
Capacity measurement water storage
resp. after 7 days 4 % higher than compared to capacity measurement after day 1 (Floating PV TÜV 2 Pfg 2750).
Long-term insulation resistance test in a water bath at 90 °C >3GΩ*m (additional internal test according to UL44 cl. 5.4 &
Increased water-repellent properties
UL2566 6.4.4.2.1)
Crushing- and impact-resistance Impact-Resistance UL 854.23 and Crushing-Resistance UL 854.24 (internal examination)
Dynamic penetration test Spring-steel-needle through insulation or sheath (EN50618 Annex D)
Sheath resistance against acid and alkaline 168 h at 23 °C in N-Oxal acid and N-Sodium hydroxide (EN 60811-404); ammoniac-resistant
Behavior in case of fire Flame-retardant acc. EN 60332-1-2 Annex A, low smoke emission (EN 61034,-2)
CPR-Performance Dca; burning behavior acc. EN 50575:2014
Halogen-free EN 50525-1, Annex B
Cold impact test EN 60811-506, EN 50618 Annex C.1 bei -40 °C
Cold elongation test Max. 30 % elongation at -40±2 °C, 16 h (EN 60811-505)
Damp heat test Duration 1000 h at 90 °C and min. 85 % relative humidity (EN 60068-2-78)
Copyright © 2024 / 2025 HIS Renewables GmbH I Subject to change. No liability for misprints.
Minimum bending radius flexible / fixed 10x cable diameter | 4x cable diameter
Temperature Range
Temperature Ambient temperature: -40 °C to +90 °C; Maximum conductor temperature: +120 °C
Maximum storage temperature +40 °C
Minimum temperature for installation -25 °C
Order No. Cross-section Construction Max. resistance External diameter Copper index Approx. Weight
black red stripes mm² n x max. - Ø (mm) (Ω/km) (+/- 0,2 mm) kg/km kg/km
www.his-solar.com
Headquarter Germany France Spain Turkey Poland
HIS Renewables GmbH HIS Renouvelables SARL HIS Soluciones de Sistemas Solares S.L. HIS Solar Sistemleri A.S. T +48 576 030 900
Siemensstraße 4 48, rue Claude Balbastre Avenida de Brasil 17 Alsancak Mah. 1479 Sk. N15 E [email protected]
64760 Oberzent 34070 Montpellier 28020 Madrid K3 D12 35220 Konak Izmir BeNeLux
T +49 606 8931 4430 T +33 467 276 820 T +34 916 620 493 T +90 232 422 0931 T +31 641 248 141
E [email protected] E [email protected] E [email protected] E [email protected] E [email protected]