AUVON-US-AS8012C-sms-v1.6-220420-80x135mm
AUVON-US-AS8012C-sms-v1.6-220420-80x135mm
Attention
The purpose of this Quick Guide is to help you
understand the operation of the TENS unit much
more quickly, and the contents of the quick guide
are not a substitute for the user manual. Please
read the user manual carefully before use to un-
derstand the contraindications and warnings.
Please consult your doctor before use if you’re not
sure whether you can use this device.
Operation
Note: Do not use it while charging.
Notes:
1. Do not overlap the pads.
2. Do not place the pads on the artery.
3. Only place the pads on the same side of the arm/leg.
1. Explanation of Pain
Pain is a warning system, a way for the body to tell us
that something is wrong. Pain is important, without it, ab-
normal conditions may go undetected, causing damage
or injury to vital parts of our bodies. Even though pain
is a necessary warning signal of trauma or malfunction
in the body, nature may have gone too far in its design.
Aside from its value in diagnosis, long-lasting persistent
pain serves no useful purpose. Pain does not begin until
coded message travels to the brain where it is decoded,
analyzed, and then reacted to. The pain message travels
from the injured area along the small nerves leading to
the spinal cord. Here the message is switched to differ-
ent nerves that travel up the spinal cord to the brain. The
pain message is then interpreted, referred back and the
pain is felt.
2. Explanation of TENS
Transcutaneous Electrical Nerve Stimulation (TENS) is
a non-invasive, drug-free method of pain control. TENS
sends tiny electrical impulses through the skin to nerves
to modify your pain perception. TENS does not cure any
physiological problems, and it only helps control pain.
TENS does not work for everyone, however, for most pa-
tients, it is effective in reducing or eliminating pain, allowing
them to return to normal activities.
3. Standard Package
● AUVON® Dual Channel TENS Massager
● Pin Pads
● Pads Holder
● Pouch
● Set of Lead Wires (½ Wire)
8
Email: support@iauvon.com
● USB Cable
● User Manual
4. Features
Mechanism Technical Description
Size 10.24cm(L)x5.54cm(W)x1.14cm(H)
9
Email: support@iauvon.com
P1-8: TENS;
P9-16: PMS;
Modes
P17-24: MASSAGE.
2 outputs with 24 modes
10
Email: support@iauvon.com
5. Product Illustrations
10
15
11
Email: support@iauvon.com
① On/Off switch
② USB port
③ Time
④ Battery indicator
⑤ Adjustable Intensity (A Channel)
⑥ Adjustable Intensity (B Channel)
⑦ Lock
⑧ Intensity Increase/ Channel A
⑨ Intensity Decrease/ Channel A
⑩ Time Selection
⑪ Mode Selection
⑫ Sub-mode selection (" < " and " > ")
⑬ Intensity Increase/ Channel B
⑭ Intensity Decrease/ Channel B
⑮ Two Outputs Connector
12
Email: support@iauvon.com
6. Operating Instructions
6.1 How to Use
14
Email: support@iauvon.com
15
Email: support@iauvon.com
8. The recommended
usage time is 10-90
minutes. Press “T” on
the device can increase
the usage time for each
selected mode (10
minutes interval). The
device will automatical-
ly turn off when time is
reached.
: ~
16
Email: support@iauvon.com
Shoulder
Modes: 1-4,6-18,20,22
Attach the pad as shown on the left.
(Do not place the pad on the spine.)
17
Email: support@iauvon.com
Back
Modes:1-4,17
Attach the two pads on the sides
of the back, do not attach it on
the spine or backbone.
Waist
Modes: 1-11,19,13-16
Attach the two pads on the sides
of the lower back, do not attach it
on the spine or backbone.
Deltoid
Modes: 2,3,4,9,14,19,22
Attach one pad in front and one
behind the muscle.
Arm
Modes: 1-24
Attach the pads on both sides of
the same arm.
Elbow
Modes: 8,12,23
Attach the pads on the upper and
lower side of the same elbow.
18
Email: support@iauvon.com
Wrist
Modes: 10
Attach the pads on the upper and
lower side of the same wrist. (Do
not place the pads on the pulse.)
Hip
Modes:
1,3,4,5,6,9,13,15,19,22
Attach the pads above and below
the pain area of your hip. (NOT
on the back)
Leg
Modes: 15
Attach the pads on both sides of
the same leg.
Knee
Modes: 1,3,7,8,9,13,19,22
Attach both pads above the knee
or above and below the pain ar-
ea.
19
Email: support@iauvon.com
Calf
Modes:
1,2,3,4,7,8,9,10,11,13,
14,15 ,16,17,18,19,22
Attach both pads on the calf/
leg where you feel pain. (Do not
place electrode pads simultane-
ously to the calves of both legs.)
Ankle/Foot
Modes: 1,4,11,13,19
Attach pads per the illustration,
on the left/ on the outside of your
ankle/foot for pain. Attach the
pads per illustration on the right/
on the other side of your ankle/
foot.
8. Mode Instruction
8.1 Intensity Recommendation
It is recommended to set the intensity within 1-3 for initial
use, feel the intensity for 1-2 minutes after each intensity
increase, if the intensity makes you feel pain or uncom-
fortable, please decrease the intensity.
8.2 Time Recommendation
It is recommended to use the device for no more than 30
minutes and to stop using it when the pain is relieved.
20
Email: support@iauvon.com
21
Email: support@iauvon.com
22
Email: support@iauvon.com
For PMS, it
is intended This program uses a
to be used pulse frequency appro-
to stimulate priate to fast twitching
healthy muscle fibers. It im-
muscles P15
proves their anaerobic
in order to capacity and is used
improve for improving maxi-
muscle per- mum muscle strength.
formance
and restore
muscle
vitality. This program gently
warms up the muscles
prior to exercise; it
feels like a rhythmic
P16 beating and comfort-
able tingling. Increase
intensity until you get a
strong but comfortable
muscle movement.
23
Email: support@iauvon.com
Comfortable tingling
from shallow to deep
P17
with 3-4 seconds
pause.
Comfortable pulsing
sensation from shal-
P18
low to deep with 3-4
seconds pause.
Variable comfortable
MASSAGE tingling, slight beating
P19
and scrapeing sensa-
tion.
For Mas-
sage, it is Comfortable slight
used to get tingling from shallow to
P20
your mus- deep with 3-4 seconds
cle relax pause.
anywhere
anytime Comfortable tingling
and bring and pulsing sensation
you ultimate P21 from shallow to more
relaxation. deep with 3-4 seconds
pause.
Rhythmic continuous
P22
beating.
Rhythmic scrapeing
P23
sensation.
High quality
ABS material to
make sure you
use it safely.
Wide
compatibility
for patches in
different sizes.
26
Email: support@iauvon.com
9.2 Instruction
Step 2
Wind the thread around the holder for easy
use as the picture shown.
27
Email: support@iauvon.com
Possible
Problem Solution
Cause
Only apply 1
Attach a pair of pad (of the
pad on the
same channel) on the skin.
skin.
Poor contact
Attach the pads to the skin
between the
(no hair) tightly.
pads and skin.
30
Email: support@iauvon.com
Possible
Problem Solution
Cause
The transpar-
Peel off film on the adhe-
ent film is still
sive surface of pads.
on the pad.
31
Email: support@iauvon.com
Possible
Problem Solution
Cause
The electrode
pad surface is Replace electrode pad.
worn out
32
Email: support@iauvon.com
Possible
Problem Solution
Cause
Insensitive
on/off button
or the on/off Reset the on/off button and
button didn’t turn it on.
Can’t reset after the
turn last use.
on the
device.
The button is Shake the device and then
stuck. turn it on again.
33
Email: support@iauvon.com
Possible
Problem Solution
Cause
34
Email: support@iauvon.com
Possible
Problem Solution
Cause
Pads are
not attached Attach both pads firmly to
to the body the skin.
firmly.
The transpar-
ent films are
Peel the film off the pads.
still on the
pads.
The pads
The Do not stack pads together
stack together
intensity or overlap. or overlap pads.
felt is
very
weak.
The cord is
not properly Connect cord correctly into
connected to the port.
the unit.
The intensity
Increase the intensity level.
is too low.
35
Email: support@iauvon.com
Possible
Problem Solution
Cause
The cord is
Power Replace the cord.
broken.
cuts off
during
The battery is
use. Charging the battery.
weak.
No
power
The battery
source
capacity is Charging the battery.
or no
depleted.
display
on LCD.
36
Email: support@iauvon.com
12. Symbols
Symbol Meaning
Class II equipment
MANUFACTURER
37
Email: support@iauvon.com
Symbol Meaning
13. Certification
The device complies with following normative documents:
ANSI/ES 60601-1, IEC60601-1-2, IEC60601-1-11, IEC
60601-2-10, ISO 10993-5, ISO 10993-10,FDA,MDD,CA65.
+1(678)829-7256
support@iauvon.com
38
AS8012C-sms-v1.6-220420-80×130mm