0% found this document useful (0 votes)
723 views167 pages

ISO Symbols

This document provides guidance on pneumatic symbols used in system diagrams and component identification. It discusses international standards for pneumatic symbols and defines basic shapes that make up pneumatic symbols, such as circles, squares, rectangles, and lines. It also describes functional elements, flowlines, connections, conditioners, pressure control components, actuators like cylinders and rotary actuators, valve symbol structure, and common valve functions. The goal is to establish a standardized set of symbols for representing pneumatic components and systems in diagrams and documentation.

Uploaded by

killimakilli
Copyright
© © All Rights Reserved
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
Download as ppt, pdf, or txt
0% found this document useful (0 votes)
723 views167 pages

ISO Symbols

This document provides guidance on pneumatic symbols used in system diagrams and component identification. It discusses international standards for pneumatic symbols and defines basic shapes that make up pneumatic symbols, such as circles, squares, rectangles, and lines. It also describes functional elements, flowlines, connections, conditioners, pressure control components, actuators like cylinders and rotary actuators, valve symbol structure, and common valve functions. The goal is to establish a standardized set of symbols for representing pneumatic components and systems in diagrams and documentation.

Uploaded by

killimakilli
Copyright
© © All Rights Reserved
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1/ 167

Pneumatic Symbols

For system diagrams and component


identification

Contents

Standards

Actuators

Basic symbols
Functional elements

Valve symbol structure

Valve functions

Three position valves

Operators

Flowlines
Connections
Conditioners and plant

Port marking

Pressure regulators

Function components

Relief valves

Symbol Library

Graphic Symbols Standards

Pneumatic symbols conform to and are devised


from the International Standard ISO 1219-1 1991
This covers graphical symbols for Fluid Power
Systems and Components
Port markings for fluid power valves are not
covered by the ISO standard. These are taken
from the recommendations of CETOP RP 68 P

Basic Symbols

Shapes

These shapes and lines in the relative


proportions shown, make up a set of basic
symbols from which fluid power symbols and
circuits are constructed

Basic Symbols (shapes)

Symbol sets can be drawn to any size but their


scale and relative proportions are determined by
a basic dimension of your choice l

Circles

energy conversion units

3/4

measuring instrument

1/3

mechanical link

1/3

roller

Basic Symbols (shapes)


l

Square

control component
connections
perpendicular to sides

Square at
45o
Rectangle

conditioning apparatus
connections to corners

>l
l

cylinders and valves

Basic Symbols (shapes)


1/4 l

Rectangles
continued

piston

1/4 l
1/2 l
min 1

cushion

l
1/2 l

max 2 l

1/2 l

certain control
methods, length
between limits to
suit

Basic Symbols
l

Semi-circle

rotary actuator, motor


or pump with limited
angle of rotation

2l

Capsule

Double line

1/5 l

pressurised reservoir
air receiver, auxiliary
gas bottle
mechanical
connection
piston rod, lever, shaft

Basic Symbols
2
10

12

Line

Working line, pilot supply,


return, electrical

Dashed

Pilot control, bleed, filter

Chain

Enclosure of two or more


functions in one unit

Line

Electrical line

Functional Elements

Functional Elements
1/2 l

Triangle

1/4 l

Direction and nature of fluid,


open pneumatic or filled
hydraulic

Spring

size to suit

Arrow

Long sloping indicates


adjustability

1/3 l

Functional Elements
Arrows

Straight or sloping
path and flow
direction, or motion

Tee

Closed path or port

Restriction

Size to suit

Functional Elements
Curved arrows

rotary motion

Shaft rotation

clockwise from right hand end


anti-clockwise from right hand end
both

Seating

90o angle

Functional Elements
Temperature

Indication or control
size to suit

Operator

Opposed solenoid
windings

Prime mover

Electric motor

Flowlines and Connections

Flowlines
Junction

Single

Junction

Four way junction

Crossing

not connected

Flexible
line

Hose usually connecting


parts with relative movement

Connections
Air bleed

Continuous
Temporary by probe

Air exhaust

No means of
connection
With means of
connection

Connections
Coupling quick
release

Both to exhaust

Coupling quick
release self sealing

Source sealed

Coupling quick
release self sealing

Both sealed

Connections
Rotary connection one
line
Rotary connection two
lines
Rotary connection
three lines

Conditioners and Pressure


Producing Plant

Conditioners

Water separator with manual drain

Water separator with automatic


drain

Filter with manual drain

Filter with automatic drain

Lubricator

Conditioners

Dryer

Cooler with and without coolant


flow lines

Heater

Combined heater / cooler

Plant

Compressor and electric


motor

Air receiver

Isolating valve

Air inlet filter

Pressure Control

Pressure regulators

A pressure regulator symbol represents a normal state with the spring holding the
regulator valve open to connect the supply to the outlet.

The dotted line represents the feedback, this opposes the


spring and can vary the flow through the valve from full flow,
through shut off, to exhaust. The symbol is usually drawn in
only this one state. The flow path can be imagined to hinge
at the right hand end to first shut off the supply then
connect to the exhaust.

Adjustable Regulator simplified

Adjustable Regulator with pressure


gauge simplified

Filter Regulator Lubricator

FRL Combined unit

FRL Simplified symbol

Pressure relief valves

A pressure relief valve symbol represents a normal state with the spring holding
the valve closed.

The dotted line represents feed-forward, this opposes the


spring and can be imagined to lift the flow path. When the
pressure reaches an excess value the flow path will line up
with the ports and flow air to relief.

Adjustable relief valve simplified

Preset relief valve simplified

Actuators

Actuators

Cylinders symbols can be


any length over l
The piston and rod can be
shown in the retracted,
extended or any
intermediate position

Single acting

Single acting sprung instroked

Single acting sprung


outstroked

Single acting sprung instroked


magnetic

Single acting sprung outstroked


magnetic

Single acting without spring

Single acting normally instroked external force


returns

Single acting normally outstroked


external force returns

Single acting normally instroked magnetic


external force returns

Single acting normally outstroked magnetic


external force returns

Note: the hardware is usually double acting cylinders applied as single acting

Double acting

Double acting adjustable cushions

Double acting through rod

Double acting magnetic

Double acting rodless

Rotary actuators

Semi rotary double acting

Rotary motor single direction of


rotation

Rotary motor bi-directional

Simplified cylinder symbols

Single acting load returns

Single acting spring returns

Double acting non cushioned

Double acting adjustable cushions

Double acting through rod

Valve symbol structure

Valve symbol structure

The function of a valve is given by a pair of


numerals separated by a stroke, e.g. 3/2..
The first numeral indicates the number of main
ports. These are inlets, outlets and exhausts but
excludes signal ports and external pilot feeds.
The second numeral indicates the number of
states the valve can achieve.

Valve symbol structure

A 3/2 valve therefore has 3 ports (normally these


are inlet, outlet and exhaust) and 2 states (the
normal state and the operated state)
The boxes are two pictures of the same valve

operated

normal

Valve symbol structure

A valve symbol shows the pictures for each of


the valve states joined end to end

operated

normal

Valve symbol structure

A valve symbol shows the pictures for each of


the valve states joined end to end

operated

normal

Valve symbol structure

The port connections are shown to only one of


the diagrams to indicate the prevailing state

normal

Valve symbol structure

The operator for a particular state is illustrated


against that state

Operated state
produced by
pushing a button

Valve symbol structure

The operator for a particular state is illustrated


against that state

Operated state
produced by
pushing a button

Normal state
produced by
a spring

Valve symbol structure

The operator for a particular state is illustrated


against that state

Operated state
produced by
pushing a button

Normal state
produced by
a spring

Valve symbol structure

The valve symbol can be visualised as moving to


align one state or another with the port
connections

Valve symbol structure

The valve symbol can be visualised as moving to


align one state or another with the port
connections

Valve symbol structure

The valve symbol can be visualised as moving to


align one state or another with the port
connections

Valve symbol structure

A 5/2 valve symbol is constructed in a similar way. A


picture of the valve flow paths for each of the two
states is shown by the two boxes. The 5 ports are
normally an inlet, 2 outlets and 2 exhausts

Valve symbol structure

The full symbol is then made by joining the two


boxes and adding operators. The connections
are shown against only the prevailing state

Valve symbol structure

The full symbol is then made by joining the two


boxes and adding operators. The connections
are shown against only the prevailing state

Valve symbol structure

The full symbol is then made by joining the two


boxes and adding operators. The connections
are shown against only the prevailing state

Valve symbol structure

The recommended spacing of the connections


1 /4 l

1/4 l

1/4 l

1
1/4 l

1/2 l
1/4 l

1/2 l

1/2 l
1/4 l

1/2 l

Valve symbol structure

The boxes can be joined at either end but the operator


must be drawn against the state that it produces. The
boxes can also be flipped
A variety of symbol patterns are possible
normally
closed

normally
open

Valve symbol structure

The boxes can be joined at either end but the operator


must be drawn against the state that it produces. The
boxes can also be flipped
A variety of symbol patterns can be produced
Reverse connected

Valve functions

Valve functions
Basic valves before
operators are added

Examples, push button operated


with spring return
Normal position

Function 2/2

Function 3/2

Valve functions
Basic valves before
operators are added

Examples, push button operated


with spring return
Operated position

Function 2/2

Function 3/2

Valve functions
Basic valves before
operators are added

Examples, push button operated


with spring return
Normal position

Function 4/2

Function 5/2

Valve functions
Basic valves before
operators are added

Examples, push button operated


with spring return
Operated position

Function 4/2

Function 5/2

Valve functions 5/3

Three position valves have a normal central


position that is set by springs or with a manual
control such as a lever
The flow pattern in the centre position varies
with the type. Three types will be considered
1, All ports sealed
2, Outlets to exhaust, supply sealed
3, Supply to both outlets, exhausts sealed

Valves 5/3

All valves types shown in the normal position

Type 1. All ports sealed

Type 2. Outlets to exhaust

Type 3. Supply to outlets

Valves 5/3

All valves types shown in the first operated position

Type 1. All ports sealed

Type 2. Outlets to exhaust

Type 3. Supply to outlets

Valves 5/3

All valves types shown in the normal position

Type 1. All ports sealed

Type 2. Outlets to exhaust

Type 3. Supply to outlets

Valves 5/3

All valves types shown in the second operated position

Type 1. All ports sealed

Type 2. Outlets to exhaust

Type 3. Supply to outlets

Valves 5/3

All valves types shown in the normal position

Type 1. All ports sealed

Type 2. Outlets to exhaust

Type 3. Supply to outlets

Operators

Operators
Manual
General manual

Lever

Push button

Pedal

Pull button

Treadle

Push/pull button

Rotary knob

Operators
Mechanical
Plunger

Pressure

Spring normally
as a return

Pilot pressure

Roller

Differential pressure

Uni-direction
or one way trip

Detent in 3 positions

Operators
Electrical
Solenoid
direct
Solenoid pilot

Solenoid pilot
with manual
override and
external pilot
supply

Solenoid pilot
with manual override
and integral pilot
supply

When no integral
or external pilot
supply is shown it
is assumed to be
integral

Port markings

Port Markings
To CETOP RP68P

12

10

12
3

14

12

14

10

12

Port Markings
To CETOP RP68P

12

10

12
3

14

12

14

10

12

Port Markings
To CETOP RP68P

12

12

10

14

12

14

10

12

Port Markings
To CETOP RP68P

12

12

10

14

12

14

10

12

Port Markings
To CETOP RP68P

12

10

14

12
3

12

10

14

12

Function components

Function components

Non-return valve simplified

Flow regulator uni-directional

Flow regulator bi-directional simplified

Two pressure AND simplified

Shuttle valve OR simplified

Note: The output can exhaust


back and is not trapped

Function components

Quick exhaust valve with silencer simplified

Silencer

Pressure to electric switch preset

Pressure to electric switch adjustable

Symbol Library

Actuators

Function Components

Solenoid Valves

Vacuum

Valves

Air Line

Electrical and
electronic

Symbol Library
Actuators

Single acting cylinders

Sprung in

Sprung out

Magnetic
sprung in

Magnetic
sprung out

Magnetic
sprung in
non-rotating
rod

Magnetic
sprung out
non-rotating
rod

Single acting cylinders

Sprung in
adjustable cushion

Sprung out
adjustable cushion

Magnetic sprung in
adjustable cushion

Magnetic sprung out


adjustable cushion

Single acting cylinders

Sprung in
adjustable cushion
non-rotating rod

Sprung out adjustable


cushion non-rotating
rod

Magnetic sprung in
adjustable cushion nonrotating rod

Magnetic sprung out


adjustable cushion nonrotating rod

Single acting bellows

Bellows single
convolution

Bellows double
convolution

Bellows triple
convolution

Double acting cylinders


Magnetic hydraulic

Non-magnetic

Non-magnetic
adjustable
cushioned

Magnetic
adjustable
cushioned

Non-magnetic
rod bellows

Magnetic

Magnetic
adjustable
cushioned
rod bellows

Double acting cylinders


Magnetic nonrotating rod

Nonrotating rod

Active
brake

Magnetic
active brake

Passive
brake

Magnetic
passive
brake

Guided rod
magnetic

Double acting cylinders

Non-magnetic through rod

Non-magnetic adjustable
cushioned through rod

Magnetic
through rod

Magnetic adjustable
cushioned through rod

Double acting cylinders

Three position adjustable


cushions (equal strokes)
Three position adjustable
cushions magnetic (equal strokes)

Four position adjustable


cushions (unequal strokes)
Four position adjustable cushions
magnetic (unequal strokes)

Other actuators

With electronic analogue


output of piston position

Slide unit

Semi-rotary actuator

Rotary motor bi-directional


and non-reversible

Rodless cylinders

Cushioned

Cushioned
magnetic

Cushioned
passive brake

Cushioned
magnetic
passive brake

Cushioned
magnetic active
brake

Cushioned
active brake

Rodless cylinders

Twin stroke
cushioned

Twin stroke
air through
carriage

Twin stroke
cushioned
magnetic

Twin stroke air


through carriage
magnetic

Shock absorbers

Self
adjusting

Adjustable

Symbol Library
Air Line Equipment

Combination units

FRL with shut off valve


and pressure gauge

Lubro-control unit

Filter and lubricator

Combination units

Breathing air set

Filter regulator

Filter regulator with gauge

Filters

Filter with manual drain

Filter with automatic drain

Filter with automatic drain


and pressure drop indicator

Pressure regulators

Pre-set relieving

Pre-set relieving with


pressure gauge

Adjustable relieving

Adjustable relieving with


pressure gauge

Pressure regulators

Pilot operated

Pilot regulator with


independent feedback

Pilot operated regulator


controlled from pilot regulator

Pressure regulators

Precision dual stage


(11-818)

Proportional pressure
valve

Lubricator

Lubricator

Pressure relief valves

Preset, no means of
connection to exhaust

Preset, tapped exhaust


port

Adjustable, no means of
connection to exhaust

Adjustable, tapped
exhaust port

Pilot operated

Other components

Silencer

Filter silencer

Water separator
automatic drain

Symbol Library
Electrical and Electronic

Sensors
Loads must be additionally suppressed

Reed switch 2 wire

brown +V
blue

Reed switch changeover

black
blue

Load

Load
Load

0V
0V
0V

brown +V

Reed switch 3 wire with led indicator


(emulating current sourcing pnp device)

brown +V
blue 0V
Load
black
0V

Reed switch 3 wire with led indicator


(emulating current sinking npn device)

blue 0V
brown +V
Load
black
+V

Reed switch 2 wire with led indicator

brown +V
blue

Load

0V

Sensors
Loads must be additionally suppressed

Solid state magnetic sensor pnp (current


sourcing)

pnp

Solid state magnetic sensor plug in cable


npn (current sinking)

black
1
3

Solid state magnetic sensor plug in cable


pnp (current sourcing)
Solid state magnetic sensor npn (current
sinking)

brown +V
blue 0V

pnp

0V

brown +V
blue 0V
black

Load

0V

blue 0V
brown +V

npn

black

Load

+V

blue 0V
brown +V

3
npn

Load

black

Solid state magnetic sensor with pulse extension

Load

+V

brown +V
blue 0V
black

Load

0V

Sensors
Loads must be additionally suppressed

Reed switch 2 wire with led indicator and


plug in cable

Reed switch 2 wire with led indicator and


plug in cable

brown +V

black

Load

0V

+ brown

blue

Load

0V

Electrical Symbols

Electrical symbols

Direct current ( DC )

Line to earth

Alternating current ( AC )

Line to chassis

AC or DC

Cell

Positive and
negative polarity

Battery

or

12 V

Electrical Components
Normally Normally
open
closed

Normally Normally
open
closed

Relay contact

General manual
switch contact

Push button
contact

Roller switch
contact

Pull button
contact

Delay to operate

Twist switch
contact

Delay to reset

Electrical Components

Relay coil

Relay coil delay to


operate contacts

Relay coil delay to


reset contacts

Solenoid valve
coil

Electrical Components

Proximity switch

Touch sensitive switch

Pressure switch

Supply and
return

24V
0V

Bell

Buzzer

Microphone

Loudspeaker

Electronic Component Symbols

Electronic Components

Opto-isolator

Resistors

Windings

inductor
inductor with core
variable inductor
transformer

Capacitors

capacitor
polarised capacitor
variable capacitor
pre-set capacitor

or

Resistor
Variable
Potentiometer
Pre-set pot
Voltage dependent
Light dependent

Diodes

diode
zener diode
light emitting diode

Electronic Components

Thyristor

Fuse

Triac

Wires connected

NPN Transistor

Wires crossing

PNP Transistor

Double junction

Photo-transistor

or

or

Electronic Components
Conductors in
a cable

Motors dc & ac

Conductors twisted

Generator

Plug and socket

Lamp steady & flashing

Coaxial plug and


socket

Operational amplifier

Meters for amps,


volts, ohms & watts

V
W

Symbol Library
Function Fittings and Components

Function fittings

Blocking fitting

12

1
2

Pressure reducing
fitting

Pneumatic sensor
fitting

1
2

Function components

Air fuse

Non return valve

Non return valve

Function components

bi-directional flow regulator


Exhaust flow regulator
with and without silencer

Silencers

Shuttle valve OR

Two pressure valve


AND (will exhaust
either signal back)

Function components

Uni-directional
flow regulator
Quick exhaust valve with
and without silencer

Rotating joint

Pressure indicator

Pressure drop indicator

Quick release couplings


made

Both to exhaust

Source sealed

Both sealed

released

Symbol Library
Solenoid Valves

Solenoid valves
with man override
on the solenoid

Direct solenoid actuated


spring return 2/2 NC

Direct solenoid actuated


spring return 3/2 NC

Direct solenoid actuated


spring return 3/2 NO

12

12
3

2
10

12

2
10

2
10

12

2
10

2
10

12
3

12

2
10
3

Solenoid valves
with man override
on the solenoid

Pilot solenoid actuated


spring return 3/2 NC

12

Pilot solenoid actuated


spring return 3/2 NO

12

Pilot solenoid actuated


pilot solenoid return

2
10
3

2
10
3

2
10

12

2
10

12

2
10

12

2
10

12
3

Solenoid valves

Pilot solenoid actuated


spring return, 5/2

14

1 3
14

Pilot solenoid actuated spring


return and manual override, 5/2

Pilot solenoid actuated


pilot solenoid return, 5/2
Pilot solenoid actuated pilot solenoid
return and manual override, 5/2

12

14

1 3

1 3

12

12

14

2
12
1 3

Solenoid valves
Reverse piped

Pilot solenoid actuated


spring return, 5/2

14

1 3
14

Pilot solenoid actuated spring


return and manual override, 5/2

Pilot solenoid actuated


and returned, 5/2
Pilot solenoid actuated and returned
with manual overrides, 5/2

12

14

1 3

1 3

12

12

14

2
12
1 3

Solenoid valves

Double pilot solenoid


actuated spring to centre
all ports sealed reverse
piped

Priority pilot solenoid


actuated differential air
return, 3/2
Priority pilot solenoid
actuated differential air
return, 5/2

14

1 3

2
10

12
3

14

12

4 2

1
4

1 3

12

Solenoid valves

Priority pilot solenoid


actuated differential air
return, 3/2

2
10

12
3

Priority pilot solenoid


actuated differential air
return, 5/2
Priority pilot solenoid
actuated air spring return,
3/2
Priority pilot solenoid
actuated air spring return,
5/2

14

1 3

5 1

12

2
10

12
3

1
14

12

Solenoid valves

Pilot solenoid actuated spring return,


manual override, 5/2 with integral flow
regulators

Double pilot solenoid actuated, manual


override, 5/2 with integral flow regulators

14

14

1 3

2
12
1 3

12

Solenoid valves
14

Double pilot solenoid actuated,


spring to centre all ports sealed,
5/3 with integral flow regulators
14

Double pilot solenoid actuated,


spring to centre supply port sealed,
5/3 with integral flow regulators
14

Double pilot solenoid actuated,


spring to centre supply to outlets,
5/3 with integral flow regulators

1 3

1 3

1 3

12

12

12

Proportional solenoid valves

Proportional flow to
electrical signal

Proportional pressure to
electrical signal

1 3

Safety related valves


12

Monitored dump valve

Soft start valve

2 10
3

12

10
3

Symbol Library
Valves

Valves un-tapped exhaust

Plunger actuated spring


return 3/2

Roller actuated spring


return 3/2

2
10

12
3

2
10

12
3

Rotary knob actuated


detented 3/2
Key actuated detented 3/2

2
10

12

Push button actuated


spring return 3/2

Toggle actuated
detented 3/2

2
10

12

2
10

12
2
10

12
3

Valves integral bleed supply

Plunger / bleed actuated


air return 3/2

Roller / bleed actuated air


return 3/2

Antenna / bleed actuated


air return 3/2

2
10

12
3

One way trip / bleed


actuated air return 3/2

Low pressure / bleed


actuated air return 3/2

2
10

12

2
10

12
3

2
10

12

2
10

12
3

Valves external bleed supply

Plunger / bleed actuated


air return 3/2

Roller / bleed actuated air


return 3/2

Antenna / bleed actuated


air return 3/2

2
10

12

One way trip / bleed


actuated air return 3/2

Low pressure / bleed


actuated air return 3/2

2
10

12

2
10

12

2
10

12

3
1

2
10

12
3

Pilot actuated valves


NC

Pilot actuated spring


return 2/2

2
10

12

Pilot actuated spring


return 3/2

12

Double pilot actuated 3/2

12

Differential pilot actuated


3/2

12

2
10

2
10
3

3
10

1
2
10

12

1
2

12

2
10

12

1
2
10

NO

1
2

12
3

10

Pilot actuated valves


NC

Pressure or vacuum
actuated spring return
2/2 (diaphragm valve)
Low pressure pilot
actuated spring return 3/2

12

2
10
3

Low pressure pilot


actuated pilot return,
3/2

12

Low pressure pilot


actuated and
returned, 3/2

12
3

1
2
10

12
3

1
2
10

12

1
2
10

2
10
3

1
2
10

12

1
2
10

12

NO

1
2
10

12
3

Pilot actuated valves

Remote pressure
bleed actuated spring
return, NC, 3/2

12

Remote pressure
bleed actuated spring
return, NO, 3/2

12

Remote pressure
bleed actuated spring
return, 5/2

12

2
10

1
2
10

1
2
10

12
3

1
2
10

2
10

12

14

1
4

1 3

12

Pilot actuated valves

Pilot actuated spring


return, 4/2

14

12

Pilot actuated spring


return, 5/2
Double pilot actuated 5/2

Differential pilot actuated


5/2

14

14

1 3

1 3

1 3

12

12

14

12

Pilot actuated valves


14

Pressure or vacuum
actuated spring return,
5/2 (diaphragm valve)

1 3

12

14

Low pressure pilot


actuated spring return, 5/2

Low pressure pilot


actuated pilot return,
5/2
Low pressure pilot
actuated and
returned, 5/2

14

1 3

1 3

12

14

1 3

12

12

Pilot actuated valves

Double pilot actuated


spring to centre all ports
sealed

Double pilot actuated


spring to centre supply
port sealed
Double pilot actuated
spring to centre supply to
outlets

1 3

1 3

1 3

Mechanically actuated valves


NC

Plunger actuated spring


return 2/2

NO
2
10

12

12

2
10

Plunger actuated spring


return 3/2

12

Plunger actuated air reset


3/2

12

2
10
3

2
10

12

2
10
3

2
10

12
3

Mechanically actuated valves

Plunger actuated spring


return, 4/2

Plunger actuated spring


return, 5/2

Plunger actuated air reset


5/2

14

14

14

12

1 3

1 3

12

12

Mechanically actuated valves


NC

Roller actuated spring


return 2/2

NO
2
10

12

12

2
10

Roller actuated spring


return 3/2

12

Roller actuated air reset


3/2

12

2
10
3

2
10

12

2
10
3

2
10

12
3

Mechanically actuated valves

Roller actuated spring


return, 4/2

Roller actuated spring


return, 5/2

Roller actuated air reset


5/2

14

14

14

12

1 3

1 3

12

12

Mechanically actuated valves


NC

One way trip actuated


spring return 2/2

12

One way trip actuated


spring return 3/2

12

One way trip actuated air


reset 3/2

12

NO
2
10

12

2
10

1
2
10
3

2
10

12

2
10
3

2
10

12
3

Mechanically actuated valves

One way trip actuated


spring return, 4/2

One way trip actuated


spring return, 5/2

One way trip actuated air


reset 5/2

14

14

14

12

1 3

1 3

12

12

Manually actuated valves


NC

Push button actuated


spring return 2/2

12

Push button actuated


spring return 3/2

12

Push button actuated air


reset 3/2

12

NO
2
10

12

2
10

1
2
10
3

2
10

12

2
10
3

2
10

12
3

Manually actuated valves

Push button actuated


spring return, 4/2

Push button actuated


spring return, 5/2

Push button actuated air


reset 5/2

14

14

14

12

1 3

1 3

12

12

Manually actuated valves


NC

Lever actuated spring


return 2/2

Lever actuated spring


return 3/2

Lever actuated air reset


3/2

NO
2
10

2
10
12

12
1

2
10

2
10

12

12
3

2
10
12
3

2
10
12

Manually actuated valves

Lever actuated spring


return, 4/2

Lever actuated spring


return, 5/2

Lever actuated air reset


5/2

14

12

1 3

1 3

12

14

14

12

Manually actuated valves

Lever actuated lever return,


variable throttling, 4/2

Lever actuated lever return,


variable throttling, detented, 4/2

Rotary knob actuated and


returned, variable throttling, 4/2

4
12

14
1

4
12

14
1

14

12
1

Manually actuated valves


14

Lever actuated spring to


centre all ports sealed

4 2

14

Lever actuated spring to


centre supply port sealed
14

Lever actuated spring to


centre supply to outlets

1 3

4 2

12

1 3

4 2

12

1 3

12

Manually actuated valves


14

Lever actuated, detented,


all ports sealed centre

4 2

14

Lever actuated, detented,


supply port sealed centre

Lever actuated, detented,


supply to outlets centre

12

4 2

5
14

1 3

1 3

12

4 2

1 3

12

Manually actuated valves


NC

Pedal actuated spring


return 3/2

Treadle actuated detented


3/2

NO
2

12
3

10
1

12
3

12

10

10
1

2
10

12
3

Manually actuated valves

Pedal actuated spring


return, 4/2

Pedal actuated spring


return, 5/2

Treadle actuated detented


5/2

14

14

14

12

2
12

1 3

1 3

12

Manually actuated valves


14

Treadle actuated spring to


centre all ports sealed

4 2

14

Treadle actuated spring to


centre supply port sealed

1 3

4 2

12

1 3

12

Manually actuated valves

Treadle actuated,
detented, all ports sealed
centre

Treadle actuated,
detented, supply port
sealed centre

4 2

14

12
5

1 3

4 2

14

12
5

1 3

Manually actuated valves

Push button actuated


rotary manual return 3/2

12
3

10
1

Push button actuated key


return 3/2
Push actuated pull
returned 3/2
Push actuated pull or air
returned 3/2

12
3

10
1

2
10

12
3

1
2
10

12
3

Safety related valves


12

Monitored dump valve

2 10
3

12

Emergency stop valve

Soft start valve

10

12

10
3

Special purpose valves


2

Impulse generator
3

Symbol Library
Vacuum Equipment

Vacuum equipment

Vacuum generator

Vacuum cups

NC

Vacuum switch
pneumatic

2
3

NO
3

2
1

Vacuum equipment

Vacuum switch electric, normally


open and normally closed

Vacuum transducer with analog


and switched outputs npn

Vacuum transducer with analog


and switched outputs pnp

V dc
Analog out
Switch out
0V

+V dc supply (brown)
Analog out (white)
Switch out (black)
Load
0 V (blue)

V dc
Analog out
Switch out
0V

+V dc supply (brown)
Analog out (white)
Switch out (black)
Load
0 V (blue)

Vacuum equipment

Vacuum filter

Vacuum silencer

Vacuum gauge

End

You might also like