ISO Symbols
ISO Symbols
Contents
Standards
Actuators
Basic symbols
Functional elements
Valve functions
Operators
Flowlines
Connections
Conditioners and plant
Port marking
Pressure regulators
Function components
Relief valves
Symbol Library
Basic Symbols
Shapes
Circles
3/4
measuring instrument
1/3
mechanical link
1/3
roller
Square
control component
connections
perpendicular to sides
Square at
45o
Rectangle
conditioning apparatus
connections to corners
>l
l
Rectangles
continued
piston
1/4 l
1/2 l
min 1
cushion
l
1/2 l
max 2 l
1/2 l
certain control
methods, length
between limits to
suit
Basic Symbols
l
Semi-circle
2l
Capsule
Double line
1/5 l
pressurised reservoir
air receiver, auxiliary
gas bottle
mechanical
connection
piston rod, lever, shaft
Basic Symbols
2
10
12
Line
Dashed
Chain
Line
Electrical line
Functional Elements
Functional Elements
1/2 l
Triangle
1/4 l
Spring
size to suit
Arrow
1/3 l
Functional Elements
Arrows
Straight or sloping
path and flow
direction, or motion
Tee
Restriction
Size to suit
Functional Elements
Curved arrows
rotary motion
Shaft rotation
Seating
90o angle
Functional Elements
Temperature
Indication or control
size to suit
Operator
Opposed solenoid
windings
Prime mover
Electric motor
Flowlines
Junction
Single
Junction
Crossing
not connected
Flexible
line
Connections
Air bleed
Continuous
Temporary by probe
Air exhaust
No means of
connection
With means of
connection
Connections
Coupling quick
release
Both to exhaust
Coupling quick
release self sealing
Source sealed
Coupling quick
release self sealing
Both sealed
Connections
Rotary connection one
line
Rotary connection two
lines
Rotary connection
three lines
Conditioners
Lubricator
Conditioners
Dryer
Heater
Plant
Air receiver
Isolating valve
Pressure Control
Pressure regulators
A pressure regulator symbol represents a normal state with the spring holding the
regulator valve open to connect the supply to the outlet.
A pressure relief valve symbol represents a normal state with the spring holding
the valve closed.
Actuators
Actuators
Single acting
Note: the hardware is usually double acting cylinders applied as single acting
Double acting
Rotary actuators
operated
normal
operated
normal
operated
normal
normal
Operated state
produced by
pushing a button
Operated state
produced by
pushing a button
Normal state
produced by
a spring
Operated state
produced by
pushing a button
Normal state
produced by
a spring
1/4 l
1/4 l
1
1/4 l
1/2 l
1/4 l
1/2 l
1/2 l
1/4 l
1/2 l
normally
open
Valve functions
Valve functions
Basic valves before
operators are added
Function 2/2
Function 3/2
Valve functions
Basic valves before
operators are added
Function 2/2
Function 3/2
Valve functions
Basic valves before
operators are added
Function 4/2
Function 5/2
Valve functions
Basic valves before
operators are added
Function 4/2
Function 5/2
Valves 5/3
Valves 5/3
Valves 5/3
Valves 5/3
Valves 5/3
Operators
Operators
Manual
General manual
Lever
Push button
Pedal
Pull button
Treadle
Push/pull button
Rotary knob
Operators
Mechanical
Plunger
Pressure
Spring normally
as a return
Pilot pressure
Roller
Differential pressure
Uni-direction
or one way trip
Detent in 3 positions
Operators
Electrical
Solenoid
direct
Solenoid pilot
Solenoid pilot
with manual
override and
external pilot
supply
Solenoid pilot
with manual override
and integral pilot
supply
When no integral
or external pilot
supply is shown it
is assumed to be
integral
Port markings
Port Markings
To CETOP RP68P
12
10
12
3
14
12
14
10
12
Port Markings
To CETOP RP68P
12
10
12
3
14
12
14
10
12
Port Markings
To CETOP RP68P
12
12
10
14
12
14
10
12
Port Markings
To CETOP RP68P
12
12
10
14
12
14
10
12
Port Markings
To CETOP RP68P
12
10
14
12
3
12
10
14
12
Function components
Function components
Function components
Silencer
Symbol Library
Actuators
Function Components
Solenoid Valves
Vacuum
Valves
Air Line
Electrical and
electronic
Symbol Library
Actuators
Sprung in
Sprung out
Magnetic
sprung in
Magnetic
sprung out
Magnetic
sprung in
non-rotating
rod
Magnetic
sprung out
non-rotating
rod
Sprung in
adjustable cushion
Sprung out
adjustable cushion
Magnetic sprung in
adjustable cushion
Sprung in
adjustable cushion
non-rotating rod
Magnetic sprung in
adjustable cushion nonrotating rod
Bellows single
convolution
Bellows double
convolution
Bellows triple
convolution
Non-magnetic
Non-magnetic
adjustable
cushioned
Magnetic
adjustable
cushioned
Non-magnetic
rod bellows
Magnetic
Magnetic
adjustable
cushioned
rod bellows
Nonrotating rod
Active
brake
Magnetic
active brake
Passive
brake
Magnetic
passive
brake
Guided rod
magnetic
Non-magnetic adjustable
cushioned through rod
Magnetic
through rod
Magnetic adjustable
cushioned through rod
Other actuators
Slide unit
Semi-rotary actuator
Rodless cylinders
Cushioned
Cushioned
magnetic
Cushioned
passive brake
Cushioned
magnetic
passive brake
Cushioned
magnetic active
brake
Cushioned
active brake
Rodless cylinders
Twin stroke
cushioned
Twin stroke
air through
carriage
Twin stroke
cushioned
magnetic
Shock absorbers
Self
adjusting
Adjustable
Symbol Library
Air Line Equipment
Combination units
Lubro-control unit
Combination units
Filter regulator
Filters
Pressure regulators
Pre-set relieving
Adjustable relieving
Pressure regulators
Pilot operated
Pressure regulators
Proportional pressure
valve
Lubricator
Lubricator
Preset, no means of
connection to exhaust
Adjustable, no means of
connection to exhaust
Adjustable, tapped
exhaust port
Pilot operated
Other components
Silencer
Filter silencer
Water separator
automatic drain
Symbol Library
Electrical and Electronic
Sensors
Loads must be additionally suppressed
brown +V
blue
black
blue
Load
Load
Load
0V
0V
0V
brown +V
brown +V
blue 0V
Load
black
0V
blue 0V
brown +V
Load
black
+V
brown +V
blue
Load
0V
Sensors
Loads must be additionally suppressed
pnp
black
1
3
brown +V
blue 0V
pnp
0V
brown +V
blue 0V
black
Load
0V
blue 0V
brown +V
npn
black
Load
+V
blue 0V
brown +V
3
npn
Load
black
Load
+V
brown +V
blue 0V
black
Load
0V
Sensors
Loads must be additionally suppressed
brown +V
black
Load
0V
+ brown
blue
Load
0V
Electrical Symbols
Electrical symbols
Direct current ( DC )
Line to earth
Alternating current ( AC )
Line to chassis
AC or DC
Cell
Positive and
negative polarity
Battery
or
12 V
Electrical Components
Normally Normally
open
closed
Normally Normally
open
closed
Relay contact
General manual
switch contact
Push button
contact
Roller switch
contact
Pull button
contact
Delay to operate
Twist switch
contact
Delay to reset
Electrical Components
Relay coil
Solenoid valve
coil
Electrical Components
Proximity switch
Pressure switch
Supply and
return
24V
0V
Bell
Buzzer
Microphone
Loudspeaker
Electronic Components
Opto-isolator
Resistors
Windings
inductor
inductor with core
variable inductor
transformer
Capacitors
capacitor
polarised capacitor
variable capacitor
pre-set capacitor
or
Resistor
Variable
Potentiometer
Pre-set pot
Voltage dependent
Light dependent
Diodes
diode
zener diode
light emitting diode
Electronic Components
Thyristor
Fuse
Triac
Wires connected
NPN Transistor
Wires crossing
PNP Transistor
Double junction
Photo-transistor
or
or
Electronic Components
Conductors in
a cable
Motors dc & ac
Conductors twisted
Generator
Operational amplifier
V
W
Symbol Library
Function Fittings and Components
Function fittings
Blocking fitting
12
1
2
Pressure reducing
fitting
Pneumatic sensor
fitting
1
2
Function components
Air fuse
Function components
Silencers
Shuttle valve OR
Function components
Uni-directional
flow regulator
Quick exhaust valve with
and without silencer
Rotating joint
Pressure indicator
Both to exhaust
Source sealed
Both sealed
released
Symbol Library
Solenoid Valves
Solenoid valves
with man override
on the solenoid
12
12
3
2
10
12
2
10
2
10
12
2
10
2
10
12
3
12
2
10
3
Solenoid valves
with man override
on the solenoid
12
12
2
10
3
2
10
3
2
10
12
2
10
12
2
10
12
2
10
12
3
Solenoid valves
14
1 3
14
12
14
1 3
1 3
12
12
14
2
12
1 3
Solenoid valves
Reverse piped
14
1 3
14
12
14
1 3
1 3
12
12
14
2
12
1 3
Solenoid valves
14
1 3
2
10
12
3
14
12
4 2
1
4
1 3
12
Solenoid valves
2
10
12
3
14
1 3
5 1
12
2
10
12
3
1
14
12
Solenoid valves
14
14
1 3
2
12
1 3
12
Solenoid valves
14
1 3
1 3
1 3
12
12
12
Proportional flow to
electrical signal
Proportional pressure to
electrical signal
1 3
2 10
3
12
10
3
Symbol Library
Valves
2
10
12
3
2
10
12
3
2
10
12
Toggle actuated
detented 3/2
2
10
12
2
10
12
2
10
12
3
2
10
12
3
2
10
12
2
10
12
3
2
10
12
2
10
12
3
2
10
12
2
10
12
2
10
12
2
10
12
3
1
2
10
12
3
2
10
12
12
12
12
2
10
2
10
3
3
10
1
2
10
12
1
2
12
2
10
12
1
2
10
NO
1
2
12
3
10
Pressure or vacuum
actuated spring return
2/2 (diaphragm valve)
Low pressure pilot
actuated spring return 3/2
12
2
10
3
12
12
3
1
2
10
12
3
1
2
10
12
1
2
10
2
10
3
1
2
10
12
1
2
10
12
NO
1
2
10
12
3
Remote pressure
bleed actuated spring
return, NC, 3/2
12
Remote pressure
bleed actuated spring
return, NO, 3/2
12
Remote pressure
bleed actuated spring
return, 5/2
12
2
10
1
2
10
1
2
10
12
3
1
2
10
2
10
12
14
1
4
1 3
12
14
12
14
14
1 3
1 3
1 3
12
12
14
12
Pressure or vacuum
actuated spring return,
5/2 (diaphragm valve)
1 3
12
14
14
1 3
1 3
12
14
1 3
12
12
1 3
1 3
1 3
NO
2
10
12
12
2
10
12
12
2
10
3
2
10
12
2
10
3
2
10
12
3
14
14
14
12
1 3
1 3
12
12
NO
2
10
12
12
2
10
12
12
2
10
3
2
10
12
2
10
3
2
10
12
3
14
14
14
12
1 3
1 3
12
12
12
12
12
NO
2
10
12
2
10
1
2
10
3
2
10
12
2
10
3
2
10
12
3
14
14
14
12
1 3
1 3
12
12
12
12
12
NO
2
10
12
2
10
1
2
10
3
2
10
12
2
10
3
2
10
12
3
14
14
14
12
1 3
1 3
12
12
NO
2
10
2
10
12
12
1
2
10
2
10
12
12
3
2
10
12
3
2
10
12
14
12
1 3
1 3
12
14
14
12
4
12
14
1
4
12
14
1
14
12
1
4 2
14
1 3
4 2
12
1 3
4 2
12
1 3
12
4 2
14
12
4 2
5
14
1 3
1 3
12
4 2
1 3
12
NO
2
12
3
10
1
12
3
12
10
10
1
2
10
12
3
14
14
14
12
2
12
1 3
1 3
12
4 2
14
1 3
4 2
12
1 3
12
Treadle actuated,
detented, all ports sealed
centre
Treadle actuated,
detented, supply port
sealed centre
4 2
14
12
5
1 3
4 2
14
12
5
1 3
12
3
10
1
12
3
10
1
2
10
12
3
1
2
10
12
3
2 10
3
12
10
12
10
3
Impulse generator
3
Symbol Library
Vacuum Equipment
Vacuum equipment
Vacuum generator
Vacuum cups
NC
Vacuum switch
pneumatic
2
3
NO
3
2
1
Vacuum equipment
V dc
Analog out
Switch out
0V
+V dc supply (brown)
Analog out (white)
Switch out (black)
Load
0 V (blue)
V dc
Analog out
Switch out
0V
+V dc supply (brown)
Analog out (white)
Switch out (black)
Load
0 V (blue)
Vacuum equipment
Vacuum filter
Vacuum silencer
Vacuum gauge
End