Wikidata:WikiProject Energy
Jump to navigation
Jump to search
Welcome to WikiProject Energy on Wikidata.
This WikiProject focuses on standardising data and bridging communities between projects so as to enable inter-project Wikidata use, such as Wikidata-supported infoboxes.
Ongoing projects
[edit]Projects by WikiProject Energy members may be listed here, for easier collaboration. Completed projects may be removed.
- Capturing information about electrical grids around the world - Wikidata:WikiProject Energy/Electrical grids
Members
[edit]The participants listed below can be notified using the following template in discussions:{{Ping project|Energy}}
Data structuring
[edit]The following sections define Wikidata structuring methods for power stations. The content has been derived from Template:Infobox power station at the English Wikipedia.
General information
[edit]Information | Structure |
---|---|
Site area | area (P2046) with qualifier applies to part (P518) as power station (Q159719)
|
Site elevation | elevation above sea level (P2044)
|
Number of chimneys | has part(s) of the class (P2670) as chimney (Q170477) with qualifier quantity (P1114)
|
Number of cooling towers | has part(s) of the class (P2670) as cooling tower (Q193886) with qualifier quantity (P1114)
|
Source of cooling | • coolant (P588) as air (Q7391292) , the waterbody or another subject.
|
Feed-in tariff | feed-in tariff (P6826) with qualifier criterion used (P1013) as kilowatt hour (Q182098) or megawatt hour (Q14787261)
|
Owner | owned by (P127)
|
Operator | operator (P137)
|
Annual revenue | total revenue (P2139) with qualifier point in time (P585)
|
Combined cycle? | instance of (P31) as combined cycle power station (Q900729)
|
Cogeneration? | instance of (P31) as cogeneration power station (Q61867910)
|
Thermal power input | specific heat capacity (P2056)
|
Currently operational units | For each unit, set powered by (P516) as the model of the generation unit (or unknown value), with the following qualifiers:• nominal power output (P2109) (if different from unit's standard capacity)• Set inception (P571) for date construction began (or unknown value)• Set service entry (P729) for date unit commissioned (or unknown value)• Do not set service retirement (P730) for date unit decommissioned. Use qualifier quantity (P1114) to multiply the entry for large sets of identical units (i.e. in wind farms).
|
Operational unit model | Enter the unit model in powered by (P516) ; manufacturer (P176) must be set in the generation unit model's Wikidata item.
|
Planned units | For each unit, set powered by (P516) as the model of the generation unit (or unknown value), with the following qualifiers:• nominal power output (P2109) (if different from unit's standard capacity)• Do not set inception (P571) for date construction began• Do not set service entry (P729) for date unit commissioned• Do not set service retirement (P730) for date unit decommissioned.
|
Cancelled units | For each unit, set powered by (P516) as the model of the generation unit (or unknown value), with the following qualifiers:• nominal power output (P2109) (if different from unit's standard capacity)• Set state of use (P5817) as cancelled (Q30108381)
|
Units under construction | For each unit, set powered by (P516) as the model of the generation unit (or unknown value), with the following qualifiers:• nominal power output (P2109) (if different from unit's standard capacity)• Set inception (P571) for date construction began (or unknown value)• Do not set service entry (P729) for date unit commissioned• Do not set service retirement (P730) for date unit decommissioned.
|
Decommissioned units | For each unit, set powered by (P516) as the model of the generation unit (or unknown value), with the following qualifiers:• nominal power output (P2109) (if different from unit's standard capacity)• Set inception (P571) for date construction began (or unknown value)• Set service entry (P729) for date unit commissioned (or unknown value)• Set service retirement (P730) for date unit decommissioned (or unknown value)
|
Installed capacity | nominal power output (P2109) with qualifier determination method or standard (P459) as nameplate capacity (Q200974)
|
Capacity factor | capacity factor (P6639)
|
Annual generation | annual energy output (P4131) with optional qualifier point in time (P585)
|
Storage capacity | energy storage capacity (P4140)
|
Geothermal power stations
[edit]Parameter | Structure |
---|---|
Type of geothermal power station | instance of (P31) :• flash steam power station (Q41722964) , or• dry steam power station (Q41722780) , or• binary cycle power station (Q4086827)
|
Minimum temperature requirement of geothermal source | operating temperature (P5066) with qualifier applies to part (P518) as water resource (Q1049799)
|
Number of geothermal wells | has part(s) of the class (P2670) as geothermal well (Q61846297) with qualifier as quantity (P1114)
|
Maximum well depth | has part(s) of the class (P2670) as geothermal well (Q61846297) with qualifier as vertical depth (P4511)
|
Hot water production | product, material, or service produced or provided (P1056) as hot water (Q1419245) , and qualifier as production rate (P2197)
|
Integrated water and power plant
[edit]Information | Structure |
---|---|
IWPP? | instance of (P31) as integrated water and power plant (Q64447720)
|
IWPP's water purification method | product, material, or service produced or provided (P1056) as water (Q283) , with qualifier fabrication method (P2079) as distillation (Q101017) and/or reverse osmosis (Q272175)
|
IWPP's maximum water output | product, material, or service produced or provided (P1056) as water (Q283) , with qualifier production rate (P2197)
|
IWPP's feed-in tariff for water output | fee (P2555) , with qualifiers criterion used (P1013) as water purification (Q1463025) andrelative to (P2210) as cubic metre (Q25517)
|
Nuclear power stations
[edit]Solar power stations
[edit]Thermal power stations
[edit]Information | Structure |
---|---|
Thermal power station types | instance of (P31) as one or more of the following:
|
Primary fuel source | source of energy (P618) with qualifier series ordinal (P1545) as 1 .
|
Secondary fuel source | source of energy (P618) with qualifier series ordinal (P1545) as 2 .
|
Tertiary fuel source | source of energy (P618) with qualifier series ordinal (P1545) as 3 .
|
Turbine technology | has part(s) of the class (P2670) as one or both:• gas turbine (Q193470) • steam turbine (Q189859)
|
Tidal power stations
[edit]Wave power stations
[edit]Information | Structure |
---|---|
Classification | instance of (P31) should be wave power station (Q3068975)
|
Wave power technology | has part(s) of the class (P2670) as one of the following:• attenuator (Q63367036) • point absorber (Q63367054) • oscillating wave surge converter (Q63367137) • oscillating water column (Q3683519) • overtopping device (Q63367204) • submerged pressure differential device (Q63367211) • bulge wave device (Q63367217) • rotating mass wave device (Q63367226)
|
Waterbody | located in or next to body of water (P206)
|
Depth of waterbody | located in or next to body of water (P206) with qualifier vertical depth (P4511)
|
Shortest distance from shore | located in or next to body of water (P206) with qualifier longest span (P2787)
|
Wind power stations
[edit]Information | Structure |
---|---|
Type of wind farm | instance of (P31) as one of the following:• onshore wind farm (Q50687555) • offshore wind farm (Q1357601)
|
Wind farm site usage | has use (P366) as one of the following:• agriculture (Q11451) • cattle husbandry (Q2153464) • wilderness (Q911871)
|
Water depth of offshore wind farm | vertical depth (P4511) with qualifier applies to part (P518) as offshore wind farm (Q1357601)
|
Shortest distance from shore of offshore wind farm | length (P2043) with qualifier applies to part (P518) as offshore wind farm (Q1357601)
|
District heating grids
[edit]- Grid
Information | Property | Value(s) | Qualifiers |
---|---|---|---|
type | instance of (P31) | district heating (Q278784) | |
year built | inception (P571) | ||
operator | operator (P137) | <item for company> (sample: Wien Energie (Q2568787)) |
- Places on grid
Information | Property | Value(s) | Qualifiers |
---|---|---|---|
available grid in locality | Wikidata:Property_proposal/district_heating | <item for grid> (sample: Fernwärme Wien (Q105687065)) |
See also
[edit]- WikiProject Energy (Q15106301)
- WikiProject Energy in English
- Wikiproyecto Energía in Español
- Projet Énergie in Français
- Proiect Energie in Română
- Wikiprojekti Energia in Suomi
- วิกิพีเดีย โครงการวิกิพลังงาน in ไทย
- 维基百科 能源专题 in 中文
- Talk pages of Portal:Energy (Q10766839) in some languages (use similar to project pages)